MODULAR BASES
Approval _______________________________
Quantity _______________________________
FCSI Section ____________________________
Date __________________________________
MODELS: 24-GM-200 36-GM-300
MODULAR CABINET BASE
GAS-FIRED STEAM GENERATOR with NICKELGUARD™
200, 250 or 300M BTU
24" (600MM) or 36" (900MM) WIDE BASE
Cleveland Standard Features
I Type 430 Stainless Steel exterior enclosure, Back Splash
and Table Top with #4 finish
I HInged Cabinet Door
I 6" Stainless Steel Legs with level adjustment and flanged
feet
I Solid State steam generator Water Level Controls
I Low Water Safety Cut-off
I Pressure Limit Controls with 15 psi Safety Valve
I Solid State Electronic Spark Ignition for energy savings
I Major components serviceable from the front of unit
I Nickelguard Steam Generator empties under pressure
(blowdown) automatically upon each Shut-Down. Automatic
Water refill on Start-Up.
I Separate "Start/Reset" Illuminated switch controls, plus
pressure Gauge
I Steam Generator Drain incorporates Water Cooling
and "Jet Rinsing"
I Insulated steam generator reduces heat loss to work area
I Standard voltage for controls is 115 volt, 60 Hz, single
phase
(Required for AZ. AR. CA. CO. CT. DE. FL. GA. HI. IL. IA. KS. MD. MA. MI. MN. MT.
NE. NV. NM. NC. OK. OR. PR. RI. TN. UT. VA. WA. WV., Buffalo, NY, Wash. DC)
ra nty
5
Ye
a
ar
100 %
I Steam Generator is complete with Access Hole/Cover Plate
and Sight Glass Gauge
I Single Cold water connection (no hot water required)
I Secondary Low Water Cut-Off, factory installed (CALG)
™
Ni
I Gas Pressure Regulator
d
elGuar
ck
r B o il e r
W
Short Form Specifications
Shall be CLEVELAND, Modular Cabinet Base, Model _____ -GM _____ M,
Nickelguard, BTU gas generator, type 304 Stainless Steel Exterior enclosure, Table Top and 6" Level Adjustable Legs. Console mounted controls,
Pressure Gauge and Illuminated "Start/Reset" control switches. Solid State
Water Level Steam Generator Controls. Steam Generator drains under pressure (blow-down) after each Shut-Down, Automatic Water Fill on Start-Up. 15
psi Safety Valve.
Options & Accessories
Ë Power Take-Off Kit (GPTO)
Ë Gas, other than natural
Ë Insulated Flue for island installation
Ë Stainless Steel Base Frame (SSF)
Ë Boiler Descaling Pump Kit (107142)
SECT.
1333 East 179 St.,
Tel: 1-216-481-4900
Web Site: www.ClevelandRange.com
Cleveland, Ohio, U.S.A. 44110
Fax: 1-216-481-3782
Email: Steam@ClevelandRange.com
E. Friedman Associates Inc.
VII
3
PAGE
0609
WATER QUALITY REQUIREMENT
The recommended minimum water quality standards
whether untreated or pre-treated, based upon 10 hours of
use per day, and a Daily Blowdown, are as follows:
TOTAL DISSOLVED SOLIDS less than 60 parts per million
TOTAL ALKALINITY
less than 20 parts per million
SILICA
less than 13 parts per million
pH FACTOR
greater than 7.5
CHLORINE
less than 30 parts per million
Consult a local water treatment specialist for an on site
water analysis for recommendations concerning steam generator feed water treatment (if required), in order to remove
or reduce harmful concentrations of minerals. The use of
highly mineralized water will mean that more
frequent servicing of the steam generator will be necessary.
The fact that a water supply is potable is not proof that it
will be suitable for the generator.
1 1/2” IPS common drain.
Do not connect other units
to this drain.
5.0 Amps
** Do not connect to GFI
outlet. See note below.
Do not use PVC pipe for
drain.
NOTES:
Right - 6”, Left - 6”, Rear - 6”
(12” on control side if adjoining
wall or equipment is over 30”
high for service access)
For use in non-combustible
locations.
Contact factory for
variances to clearances.
VII
4
(NOT TO SCALE)
**DO NOT CONNECT TO GFI OUTLET. CLEVELAND RANGE RECOMMENDS GAS FIRED 120 VOLT STEAMERS BE HARD WIRED DIRECTLY TO ELECTRICAL SYSTEM.
Cleveland Range reserves right of design improvement or modification, as warranted.
Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes.
Cleveland Range equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are ASME/N. Bd, NSF and CSA (AGA, CGA).