The Emerson ASCO 300 Series automatic transfer switches (ATS) are designed to provide reliable power transfer between two sources, ensuring continuity of critical loads during power outages. With a wide range of features and capabilities, these ATS are ideal for various applications, including healthcare facilities, data centers, industrial plants, and commercial buildings.
advertisement
Power Switching & Controls for Business-Critical Continuity ™
Series 230 Automatic Transfer Switch
Global Headquarters-Florham Park,
New Jersey
ASCO was founded in 1888, and manufactured the first ATS in 1920, ASCO focuses on the development of ATS, and has become the leader in the ATS industry.
The picture on above is ASCO’s headquarters, located in Florham Park, New Jersey. ASCO has more than 1600 employees and more than 4 factories covering over 500,000 square feets of manufacturing floor space in North America and Asia. ASCO has installed more than 500,000 automatic transfer switches worldwide. No other manufacturer comes close.
The more you know, the more confidence you have in choosing
ASCO provides diversified products and solutions to match different requirements:
• Automatic Transfer Switch ATS
• Closed Transition Transfer Switch CTTS
• Delayed Transition Transfer Switch
DTTS
• Automatic Transfer Bypass-Isolation
Switch ATB
• Automatic Closed Transition Bypass-
Isolation Switch ACTB
• Static Transfer Switch STS
• Soft Load Transfer Switch SLTS
• Medium Voltage Automatic Transfer
Switch MVATS
• Medium Voltage Closed Transition
Transfer Switch MVCTTS
• Three Position Automatic Transfer
Switch Center-off
• Multi-Sources Transfer System
• Multi-Generator Parallel Power
Connection Systems
• Emergency Power Management
System
• Lighting Control Contactors
• Surge Protection Device
Standards
• GB14048.11
• IEC/EN 60947-6-1
• UL1008
• NFPA20,70,99,110
• IEEE241.446
• NEMA ICS101993
1
The Recognized Leader in Power Transfer
Switch Technology Offers the Most
Advanced Transfer Switches in the World.
Product Overview
The Series 230 automatic transfer switch consists of an intelligent controller and a modular load break switch which automatically transfers the load to the emergency power source when it detects under/over voltage, under/over frequency, or phase failure. The switch has three operation positions (source one - center off - source two). The two sources can be isolated in the center off position. A position locking mechanism is also provided.
Application
The Series 230 capacity is up to 400A, available from 220 to 415 volts, 50 and 60Hz, single phase and three phase. Typical applications include office buildings, residential buildings, telecom, hospital, subway, data center, military, transportation, and fire pump applications.
Parameter
Rated Operational Current Ie (A)
Rated Insulation Voltage U i
(V)
Rated Impulse Withstand Voltage U imp
(kV)
Rated Operation Voltage U e
(V)
Rated Frequency (Hz)
Poles
Rated Short-Time Withstand Current I cw
(kA, RMS)
Rated Short-Circuit Making Capacity I cm
(kA, PEAK)
Withstand and Close-
On Rating I q
(kA)
When Used With Current
Limiting Fuses
When Used With Specific
Circuit Breakers
Making and Breaking Capacity
Mechanical Operation Performance (cycles)
Utilization Category
Operation Voltage
range (AC)
Ue=220V / 230V / 240V /
380V / 400V
Ue= 415V
EMC Class
Wiring Way
Separate Lock Mechanism
Auxiliary Contact
32 40 50 63 80 100 125 160 200 225 250 315 400
800
8
220, 230, 240, 380, 400, 415
10 (0.1s)
17
50 / 60
2, 3, 4
800
12
15 (0.1s)
31.5
800
12
25 (0.1s)
65
65 200 200
10 I e
10,000
AC - 33B
(0.7〜1.2) × Ue
(0.7〜1.15) × Ue
Class A
Front
Standard
Optional (8 contacts maximum)
150 150
2
Series 230 Automatic Transfer Switch Product Features
Performance feature
• Meets or exceeds the requirements of the following regulatory agencies
• EN60947-6-1/IEC60947-6-1: transfer switching
• EN55022: Radiated and Conducted Emission,
Class A
• EN61000-3-2: Harmonic Current Emission, Class A
• EN61000-3-3: Limits of Voltage fluctuation and
Flicker
• EN 61000-4-5: Immunity to Surge
• EN 61000-4-4: Immunity to Electrical Fast
Transient:
• EN61000-4-2: Immunity to Electrostatic
Discharge
• EN61000-4-3: Immunity to Radiated Electric
Fields
• EN 61000-4-6: Immunity to Continuous
Conducted Interference
Structure
• PC Class ATS
• High ability of withstanding lightning strikes (40kA 8/20μs)
• Simple reliable mechanism, compact and stylish appearance
• Modular design, convenient operation, easy maintenance
• Three operation positions. Two sources can be isolated in the center-off position
Arc Extinguish
• The utilization category is AC-33B, and the ability of withstand and break is10 I e
• Rotating dual contacts design extinguishes the arc quickly and effectively
• Arcing contacts and main contacts are separate, avoids main contacts from being destroyed by an arc
• Clamping contacts are self cleaning wiping action type
• High short-circuit closing ability
Switching Mechanism
• Both automatic and manual operation are available
• Unique contacts design limits contact bounce
• Unique clutch technique makes manual operation easy to do
• Electrical and mechanical interlocks prevent two sources from connecting simultaneously
• Innovative motor circuit protection technique, provides precision control
• Cast steel bevel gear mechanism provides high transmission efficiency, and extends the operation life
Controller
• Different Operating Modes (Source I priority/ No Source priority)
• C2000 has ability to work with external
24VDC power supply
• High frequency switching power supply, and wide power voltage range
• Controller remains operational when power is lost, and avoids data loss
• Diagnosis fault intelligent with self - protection function (Motor-Protection)
• RS485 communication interface is available
3
Make Life and Business More Reliable
By Using ASCO
Series 230 Transfer Switch Ordering Information
B2ADTL
①
①
③
⑤
⑥
⑦
B3
②
03
03
03
B3
B2
B2
03
03
B3
B3
B3
B3
02
02
02
B2
B1
B1
B1
02
Frame
Amps
Controller
Optional
Accessories
Enclosure
B2ADTL
C2ADTL
D2ADTL
0032
0040
0050
0063
0080
0
X
D
E
0
Type sample:
250
③
Switch category
H
④
K
C
H
J
C
D
E
F
J
K
D
H
F
D
D
E
F
C
D
E
32A
40A
50A
63A
80A
L1
N
Source I
L1
L2
Source I
L1
L2
N
Source I
L1
L2
L3
Source I
L1
L2
L3
N
E
⑤
Source I
0
⑥
M
0
⑦
L1
N
Source II
M
L1
L2
Source II
M
M
M
L1
L2
N
Source II
L1
L2
L3
Source II
L1
L2
L3
N
Source II
Poles
2P
3P
Line and Neutral
L1 L2
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
4P √
√
√
√
√
√
√
√
√ √
B2ADTL Frame 32A-160A
C2ADTL Frame 200A-250A
D2ADTL Frame 315A-400A
L3
√
√
√
√
√
√
√
√
√
√
N
√
√
√
√
√
√
√
√
√
√
√
AC Voltage (V)
L-L
-
L-N
220
-
230
240
208
220
230
240
-
-
-
110 220
230
240
208
115
120
-
-
220
380
400
415
-
-
-
-
208
220
380
400
415
-
220
230
240
0100
0125
0160
0200
0225
100A
125A
160A
200A
225A
0250
0315
0315
0400
250A
315A
315A
400A
C1000 Controller
C2000 Controller
Without Accessories
B2ADTL Frame Bridging Bus Bar: 132JA 〜 132JC, Auxiliary Contacts: 132A 〜 132F See Page 5
Without Enclosure
4
5
Optional Accessory Model Description and Order Information
B2ADTL Frame Bridging Bus Bar
132 J A
Poles
A: 2 poles
B: 3 poles
C: 4 poles
Function Code 132J: Bridging Busbar
4 poles Bridging Busbar
For example: 132JC , means Bridging Busbar for a 4 poles transfer switch
Auxiliary Contacts
132 A A
Auxiliary Contact Quantity
BLANK: 1 contact
A: 2 contacts
B: 3 contacts
C: 4 contacts
Function Code 132A-132F: Auxiliary Contact Auxiliary Contact
For example: 132BA , means 2 sets of contacts, closed when the ATS transfer to source II position.
The Auxiliary Contact Definition
132A-132C : The auxiliary contacts can be used to indicate positions with the CLOSE contact , see Schematic 1.
132D-132F: The auxiliary contacts can be used to indicate positions with the OPEN contact ,see Schematic 2.
Position of
The transfer switch
I
0
II
Auxiliary Contact Function
132A 132B 132C
Position of
The transfer switch
I
0
II
Auxiliary Contact Function
132D 132E 132F
I
0
II I
0
II
0
II
I
0
II
I
Schematic 1 132A-132C Diagram Schematic 2 132D-132F Diagram
Avoid Losing Critical information
When Power is Lost
Series 230 Dimensions and Weight
B2ADTL Frame
A
B2ADTL
Size (mm)
Weight (kg)
A
2P
241.0
2.6
Note: It must be installed in DIN35 Rail to the cabinet
3P
349.0
2.8
(unit: mm)
4P
349.0
2.8
C2ADTL Frame
23
167.8
Ø6
177.3
12.5
20
9
C2ADTL
Size (mm)
Weight (kg)
A
B
C
23
171.5
9
6
2P
251.0
236.0
68.0
4.6
B
A
17 34 34
C
34
3P
285.0
270.0
102.0
5.2
126 130
(unit: mm)
4P
319.0
304.0
136.0
5.8
6
D2ADTL Frame
172.8
215
198.5
140 120
Ø7 15.5x10.5
D2ADTL
Size (mm)
Weight (kg)
A
B
C
2P
317.0
297.0
103.0
8.6
A
B
44
120 157.8
186.3
3P
361.0
341.0
147.0
9.8
(unit: mm)
4P
405.0
385.0
191.0
11.0
Shipping Dimensions and WeightsShipping Dimension and Weights (Including TS and controller, without options)
Frame
Width
(MM)
Height
(MM)
Depth
(MM)
Weight (KG) with C1000
2P 3P 4P
Weight (KG) with C2000
2P 3P 4P
B2ADTL 602 220 267 4.9 5.5 5.7 5.2 5.8 6.0
C2ADTL
D2ADTL
602
650
335
350
227
300
8.9
13.0
9.5
14.5
10.1
16.0
9.2
13.4
9.8
14.9
10.4
16.4
* All information is subject to change, for the latest information please contact ASCO sales team.
7
ASCO Power Transfer Switch Solutions for
Powerful Peace of Mind
Series 230 Controller Feature Comparisons
C1000 Controller
Voltage and Frequency Sensing
• 3-Phase under and over voltage settings on source I and source II
• Phase lose sensing on source I and source II
• Under and over frequency settings on source I and source II
Time Delays
• Time delay sensing accuracy is ±1%
• Transfer time delay can be set manually
Controller Display and Keypad
• LED display
• Touch pad for clearing alarm and manual operation
• Switch position indicator lights
• Source acceptability indicator lights
Operating Modes
• Automatic and manual operation available
• Source I Priority/ No Source Priority
Center-off with time delay and center-off with protection
• The center-off time delay can be set to avoid large current rushes to inductive loads
• Center-off with protection is available to protect critical loads (e.g.
Fire Pump)
Remote Control and Communication
• Can control switch remotely (e.g. Position Control, Time Delay, etc.)
• Fire control signal input (24VDC)
Power Supply of Controller
• Operation Voltage (VAC): 220/ 230/ 240/ 380/ 400/ 415
C2000 Controller
Voltage and Frequency Sensing
• 3-Phase under and over voltage settings on source I and source II
• Under and over frequency settings on source I and source II
• Voltage unbalance detection between phases
Time Delays
• Time delay can be set by operating parameter setting menu
• Time delay sensing accuracy is ±1%
• Time delay can be set under different working modes
• Transfer time delay can be set manually
Controller Display and Keypad
• LCD display
• Touch pad for programming the features and settings
• Switch position indicator lights
• Source acceptability indicator lights
Operating Modes
• Automatic and manual operation available
• Source I Priority/ No Source Priority
Center-off with time delay and center-off with protection
• The center-off time delay can be set to avoid large current rushes to inductive loads
• Center-off with protection is available to protect critical loads (e.g.
Fire Pump)
Events Display
• Event log displays: 100 logged events with time and date of each event, event type and event reason
Remote Control and Communication
• Uses RS485 interface, and supports MODBUS Communication
• Can control switch remotely (e.g. Position Control, Time Delay, etc.)
• Fire control signal input (24VDC)
Power Supply of Controller
• Operation Voltage (VAC): 220/ 230/ 240/ 380/ 400/ 415
• C2000 has ability to work with 24VDC power supply
8
24-hours Protection No Matter When
Trouble Strikes
Controller
Intended Application
Rated Operation Voltage U e
(V)
Rated Frequency (Hz)
Display Indicator
Source I Available
Source II Available
Source I Accepted (Load Connected)
Source II Accepted (Load Connected)
Center-off Position
Control Mode
Manual/Automatic
Source I Priority
No Source Priority
Source Sensing Setting
Phase Selection
Source I Voltage
Source II Voltage
Source I Frequency
Source II Frequency
Source I power loss
Source II power loss
Source I phase loss
Source II phase loss
Source I Voltage Dropout (Undervoltage)
Source II Voltage Dropout (Undervoltage)
Source I Overvoltage Trip
Source II Overvoltage Trip
Source I Overfrequency Transfer
Source II Overfrequency Transfer
Source I Frequency Dropout (Underfrequency)
Source II Frequency Dropout (Underfrequency)
Source I Voltage Pick Up
Source II Voltage Pick Up
Source I Frequency Pick Up
Source II Frequency Pick Up
Time Delay Setting
Override Momentary Source I Outage
Override Momentary Source II Outage
Transfer to Source I
Transfer to Source II
Engine Cooldown
Center-Off Position Delay
Others
RS-485
Modbus
24VDC Capable
Generator Control Signal Output
Fire Control Signal Input
Alarm
Auxiliary Contact
Events Log
Display Type
Installation
C1000
Residential, Light Commercial
220/230/240/380/400/415
50/60Hz
70% or 85%
70% or 85%
OFF or 120% 1
OFF or 120% 1
110% or 115%
110% or 115%
85% or 90%
85% or 90%
75% or 90%
75% or 90%
90% or 95%
90% or 95%
0 to 3 Seconds
0 to 3 Seconds
1s to 30 Minutes
0 to 5 Minutes
5 Minutes Fixed
OFF or 5 Seconds
Optional
LED
Din rail installation and Panel installation
■ -Yes, Standard Blank-Not Available/ Not Applicable
1 the controller used on 415V, its Overvoltage Droupout is 115% both on Source I and Source II
9
C2000
Commercial, Industrial
220/230/240/380/400/415
50/60Hz
70% to 98%
70% to 98%
102% to 120% or OFF 1
102% to 120% or OFF 1
102% to 115%
102% to 115%
85% to 98%
85% to 98%
85% to 100%
85% to 100%
90% to 100%
90% to 100%
0 to 3 Seconds
0 to 3 Seconds
0 to 30 Minutes
0 to 5 Minutes
0 to 60 Minutes
0 to 5 Seconds
Optional
LED+LCD
Panel installation
C1000 Controller Port Function Description
24V
Generator start
GEN
Alarm
ALM
X1 Power terminal
Voltage Detection
Fire control input
Transfer to
Position O
DI5 FIRE
X3 User terminal
Transfer to
Position I
DI6
Transfer to
Position II
DI7
C1000 CONTROLLER
X2 control terminal
Transfer switch position detection and transfer control
To
Transfer
Switch X1
To
Transfer
Switch X2
10
Critical Loads Demand ASCO
C2000 Controller Port Function Description
24V
Alarm
ALM
O I II
TS position
DO1 DO2 DO3
X1 Power terminal
Voltage Detection
Generator start
GEN
RS485
Fire control input
FIRE
Transfer to
Position O
DI5
Transfer to
Position I
DI6
Transfer to
Position II
DI7 485 PORT
X4 User terminal
C2000 CONTROLLER
X2 control terminal
Transfer switch position detect and transfer control
X3 User terminal
24V DC
power input
Lost power
To
Transfer
Switch X1
To
Transfer
Switch X2
24V
11
Controller Dimensions and Weight*
C1000 Controller
80.7
58.7
94±0.5
93.5
Panel Opening Dimensions
C2000 Controller
Run Auto Alarm
Source I Source II
Transfer Switch Position
Esc
UP
Down
Enter
197
*Not Shipping weight, Actually unit weight
189
Weight: 0.74kg
(unit: mm)
191±1
Panel Opening Dimensions
Weight: 1kg
(unit: mm)
12
About Emerson Network Power
Emerson Network Power, a business of Emerson (NYSE:EMR), protects and optimizes critical infrastructure for data centers, communications networks, healthcare and industrial facilities. The company provides new-to-the-world solutions, as well as established expertise and smart innovation in areas including
AC and DC power and renewable energy, precision cooling systems, infrastructure management, embedded computing and power, integrated racks and enclosures, power switching and controls, and connectivity. Our solutions are supported globally by local Emerson Network Power service technicians. Learn more about Emerson Network Power products and services at www.emersonnetworkpower.com
About Emerson
Emerson (NYSE: EMR), based in St. Louis, Missouri (USA), is a global leader in bringing technology and engineering together to provide innovative solutions for customers in industrial, commercial, and consumer markets around the world. The company is comprised of five business segments: Process Management,
Industrial Automation, Network Power, Climate Technologies, and Commercial & Residential Solutions. Sales in fiscal 2012 were $24.4 billion. For more information, visit: www.emerson.com
Emerson Network Power Co., Ltd.
Address: No.1 Kefa Road, Science & Industry Park,
Nanshan District, 518057 Shenzhen
China Telephone: 86-755-86010808
Service Hotline: 4008876510
Postcode: 518057
Emerson Network Power
The global leader in enabling Business-Critical Continuity ™ www.emersonnetworkpower.com
AC Power
Connectivity
DC Power
Embedded Computing
Embedded Power
Infrastructure Management & Monitoring
Outside Plant
Power Switching & Controls
Precision Cooling
Racks and Integrated Cabinets
Services
Surge Protection
Emerson Network Power, ASCO, the Emerson Network Power logo and ASCO logo are trademarks and service marks of Emerson Electric Co. ©2013 Emerson Electric Co.