ENSURE CONTINUITY OF POWER SUPPLY
EPO (EMERGENCY POWER OFF)
DISCONNECT POWER
IN CASE OF FIRE
DATA SHEET
POWERLINE RT
1/2/3 kVA
RACK/TOWER
ENCLOSURE
EXTERNAL
BATTERY MODULE(S)
COLD START
START FROM
BATTERY
A series of double-conversion On-Line (VFI) topology UPS, which provides excellent protection for the connected receivers, such
as computer systems, by filtrating disruptions on the receiver's power supply line.
COMMUNICATION
FEATURES
• Rack/Tower enclosure
• RS232 and USB communication interface
• Easy battery replacement
• NMP/HTTP network management card
• Automatic detection of optional battery packs
PROTECTION
• ECO mode enabling high efficiency
• Variable fan speed for noise reduction
• Overload
• Remote Power On/Off (ROO) function
• Short circuit
• Emergency Power Off automatic power-off system
• Surge
• Microprocessor-based steering circuit for reliable operation
• Thermal
• Battery
SUPPORT
• Door-to-door support
• 2 year warranty for the UPS
• 2 year warranty for batteries
• Repair in 5 business days
2015-12-01 EN
www.ever.eu
POWERLINE RT
1/2/3 kVA
TECHNICAL DATA
POWERLINE RT
PARAMETERS \ TYPE
Part number
Output Power (Apparent / Active)
1)
POWERLINE RT 1000
POWERLINE RT 2000
POWERLINE RT 3000
T/PWRLRT-111K00/00
T/PWRLRT-112K00/00
T/PWRLRT-113K00/00
1000 VA / 800 W
2000 VA / 1600 W
3000 VA / 2400 W
Note: The manufacturer reserves the right to modify the above parameters without prior notification
GENERAL DATA AND ENVIRONMENTAL
Topology
VFI (on-line, VFI-SS-111)
Number of phases (in/out)
1/1
Housing Type 2)
Max efficiency (double conversion mode)
Rack / Tower
86 %
88 %
Max efficiency (ECO mode)
90 %
˃ 93 %
Operating temperature 3)
0 ÷ +40 °C
-15 ÷ +40 °C with batteries
-25 ÷ +50 °C without batteries
Storage temperature
Relative humidity during operation
< 95% (non-condensing)
Relative humidity during storage
< 95% (non-condensing)
Operating elevation 4)
< 3000 m
Protection level
IP20
Environment of installation
Office / industrial rooms with low level of pollution
Cooling
Forced, internal fans
Temperature of the cooling air
Quantity of heat released for nominal work conditions
< 25°C
< 450 BTU / h
< 750 BTU / h
< 1000 BTU / h
INPUT
Nominal input voltage
Input voltage range and tolerance
Rated current
230 V AC
120 ÷ 275 V AC ± 2%
6A
Input voltage rated frequency
Input voltage frequency range and tolerance
140 ÷ 275 V AC ± 2%
12 A
16 A
50 / 60 Hz
40 / 70 Hz (range of synchronization input-output: 50/60Hz: ± 5 % )
Input Power Factor
≥0,99
Input current distortion (THDi)
< 8%
Notes:
1) For standard operation, the load applied to the output must not exceed 80% of the value in the table. The power margin is necessary to ensure continuous
work of the connected devices in the case of instantaneous surges of the load.
2) The rack kit available as an option.
3) For UPS with internal batteries 5 ÷ 35 °C. Constant exposure of the battery module to temperatures of +25°C reduces the battery life.
4) The permitted maximum load of the power supply unit decreases with the height above the sea level above the limit specified above.
EPO
EPO (Emergency Power Off) is a mechanism that allows to interrupt energy supply to loads from the output of UPS in extreme
situations (e.g. fire). The mechanism may be triggered by opening a dedicated pins attached to the external connectors located
EPO
on the rear side of the housing or induced remotely from the user interface.
2015-12-01 EN
www.ever.eu
POWERLINE RT
1/2/3 kVA
TECHNICAL DATA
POWERLINE RT
PARAMETERS \ TYPE
Part number
Output Power (Apparent / Active)
1)
POWERLINE RT 1000
POWERLINE RT 2000
POWERLINE RT 3000
T/PWRLRT-111K00/00
T/PWRLRT-112K00/00
T/PWRLRT-113K00/00
1000 VA / 800 W
2000 VA / 1600 W
3000 VA / 2400 W
OUTPUT
Nominal output voltage
230 V AC
Output voltage range and tolerance - normal mode 5)
200 V AC / 208 V AC / 220 V AC / 230 V AC / 240 V AC ± 2 %
(Output voltage value set with LCD panel. Default 230 V AC)
Output voltage range and tolerance - battery mode 5)
200 V AC / 208 V AC / 220 V AC / 230 V AC / 240 V AC ± 2 %
(Output voltage value set with LCD panel. Default 230 V AC)
Shape of output voltage (battery mode / normal
mode)
sine-wave / sine-wave
Output voltage rated frequency
Output frequency range and tolerance - mains
operation mode
50 / 60 Hz
50 / 60 Hz ± 0,5%
(The same as the input or selected in mode frequency conversion)
Output frequency range and tolerance - battery mode
50 Hz ± 0,5%
Output voltage regulation
± 1%
≤ 4% for Pmax (line)
≤ 6% (non
-line)
Output voltage distortion THDu
Note: The manufacturer reserves the right to modify the above parameters without prior notification
Crest Factor CF
3:1
Transfer time to battery mode
0 ms
Transfer time to normal mode
0 ms
< 110% - warning
111% ÷ 135% - 12 s (UPS to bypass)
> 135% - 1,5 s (UPS off)
Overload capability 6)
BATTERIES AND TYPICAL RUNTIME
Internal Batteries
Number of internal batteries
12 V / 9 Ah VRLA
12 V / 9 Ah VRLA
1x3
1x6
Maximum overall internal batteries capacity
9 Ah
External battery modules (EBM)
Yes
Maximum number of EBMs
4
Backup time - internal batteries ( 100 % / 80 % / 50 %
Pmax)
8 / 12 /20 min
8 / 12 / 20 min
3 / 6 / 12 min
Backup time - internal batteries + EBM
(100%/80%/50%Pmax)
26 / 37 /78 min
26 / 37 / 78 min
20 / 28 / 41 min
Nominal voltage DC circuit
36 V DC
72 V DC
Internal batteries maximum charging time - after
discharging at 80 % Pmax
≤ 4h
Maximum charging current
1,2 A
MECHANICAL SPECIFICATIONS
Dimensions (H x W x D)
Net Weight 7)
Gross Weight
7)
Transport Dimensions (H x W x D)
86 (2U) x 438 x 482 mm
86 (2U) x 438 x 658 mm
18,5 kg
30,5 kg
22 kg
35 kg
245 x 530 x 625 mm
Position in which devices transported
31 kg
36 kg
230 x 585 x 880 mm
Horizontal
Notes:
5) Set by user software or LCD display. For the rated output voltage of 200 V there is 20% output power reduction. For the rated output voltage of 208 V there
is 10% output power reduction
6) With long-term operation of the load of the recommended values.
2015-12-01 EN
www.ever.eu
POWERLINE RT
1/2/3 kVA
Note: The manufacturer reserves the right to modify the above parameters without prior notification
TECHNICAL DATA
POWERLINE RT
PARAMETERS \ TYPE
POWERLINE RT 1000
POWERLINE RT 2000
POWERLINE RT 3000
T/PWRLRT-111K00/00
T/PWRLRT-112K00/00
T/PWRLRT-113K00/00
1000 VA / 800 W
2000 VA / 1600 W
3000 VA / 2400 W
Short-circuit protection –
Circuit breaker
10 A / 250 V AC
Short-circuit protection –
Circuit breaker
12 A / 250 V AC
Short-circuit protection –
Circuit breaker
16 A / 250 V AC
Part number
Output Power (Apparent / Active)
1)
PROTECT
Input over current protection
Surge Protection
Output over current protection
Inverter working – electronic short-circuit and overload protection
ACCESSORY AND EXTRA FUNCTIONS
Power supply connection
Output connection (number and type of sockets )
1 x IEC 320 C14 (10 A)
1 x IEC 320 C20 (16 A)
3 x IEC 320 C13 (10A) of them controllable (2 groups)
3 x IEC 320 C13 (10A)
3 x IEC 320 C13 (10A) of them
controllable (2 groups)
3 x IEC 320 C13 (10A)
1 x IEC 320 C19 (16A)
EPO / ROO
Yes (NC) / Yes
Signalling
Acoustic and optical; LCD display
RS232, USB, Port RJ11 – port for battery pack detection cable,
network management card SNMP / HTTP – (optional),
AS 400 card - optional
Communications interfaces
Software
PowerSoft Professional
GREENPOWER activation threshold 8)
< 45 W
CERTIFICATION
Declarations
CE
Standards
PN-EN 62040-1:2009, PN-EN 62040-2:2008
Notes:
7) Weight for the typical battery.
8) In battery mode with no load or load less than treshold value, UPS turn off automatically after 5 minutes.
UPS POWERLINE RT 1000/2000/3000
UPS STRUCTURE-FRONT PANEL
2015-12-01 EN
1
2
3
BYP/
ECO
4
BYP/
ECO
8
5
7
9
6
www.ever.eu
1) Power grid mode LED
2) Bypass/ECO mode LED
3) Error LED
4) LCD display
5) Output button
6) Scrolling button
7) ON/OFF button/Backup mode LED
8) Confirm button
9) 2 sets of tower bases for vertical installation
POWERLINE RT
1/2/3 kVA
UPS STRUCTURE-BACK PANEL
1
2
3
1) RS232 port
2) USB port
4
12
3) ROO/EPO terminals
4) Fan
5
5) RJ11 port battery module detection
6
6) Supply interface to connect an external battery pack
7
7) SNMP card socket
8) Input circuit protection automatic fuse
9) Power supply input socket
9
8
11
10
10) Non-controlled 10 A output sockets
11) Controlled 10 A output sockets (group 1 and 2)
12) Earthing bolt
UPS POWERLINE RT 1000
1
1) SNMP card socket
2) Fan
2
3) Supply interface to connect an external battery pack
4) RJ11 port battery module detection
5) RS232 port
3
11
10
12
6) Input circuit protection automatic fuse
7) Power supply input socket
4
8) Non-controlled 10 A output sockets
5
6
9) Controlled 10 A output sockets (group 1 and 2)
10) ROO/EPO terminals
7
11) USB port
8
12) Earthing bolt
9
UPS POWERLINE RT 2000
2015-12-01 EN
www.ever.eu
POWERLINE RT
1/2/3 kVA
UPS STRUCTURE-BACK PANEL
1
1) SNMP card socket
2) Fans
3) Supply interface to connect an external battery pack
2
4) RJ11 port battery module detection
5) RS232 port
3
13
4
12
11
5
6
10
7
9
8
6) Input circuit protection automatic fuse
7) Power supply input socket
8) Non-controlled 10 A output sockets
9) Controlled 10 A output sockets (group 1 and 2)
10) 16 A output sockets
11) ROO/EPO terminals
12) USB port
13) Earthing bolt
UPS POWERLINE RT 3000
1
1
2
2
3
3
1) Battery pack power supply interface
4
2) RJ11 port - signal lead
4
3) Battery pack power supply interface
4) Current protection
POWERLINE RT 1000
BATTERY PACK
POWERLINE RT 2000 / 3000
BATTERY PACK
EVER Sp. z o.o.
ul. Wołczyńska 19, 60-003 Poznań, Poland
tel. +48 61 6500 400, fax +48 61 6510 927,
e-mail: ups@ever.eu
www.ever.eu