PCD-H 10

www.co-ax.com
data sheet
E7.11-11/2009
lateral valve
type PCD-H 10
5-PCD-H 10
valve type with pilot valve
2/2 way valve
pressure range
orifice
connection
function
externally controlled
PN 0-500 bar
DN 10 mm
thread
valve
normally closed
symbol
NC
valve
normally open
symbol
4
B
a
4
NO
b
a b
2
A
③
④
⑤
⑥ stainless steel
PTFE, FPM, CR, EPDM
options
general specifications
ports
details needed for main valve
■ orifice
■ port
■ function NC/NO
■ operating pressure/Δp
■ flow rate
■ media
■ media temperature
■ ambient temperature
■ type of actuation
function
pressure range
Kv value
vacuum
pressure-vacuum
back pressure
media
details needed for pneumatic actuation
■ nominal voltage
■ type of protection
■ actuation pressure range min/max
■ low wattage coil, actuation pressure range 4-7 bar
■ pilot valve type
abrasive media
damping
flow direction
switching cycles
switching time
media temperature
ambient temperature
flush ports
leak ports
limit switches
manual override
approvals
mounting
weight
additional equipment
PCD-H
threads G 3/8
bar
NC
0-500
m³/h
leak rate
P1 P2
P2 > P1
opening
closing
AB
1/min
ms
°C
°C
NO
1,5
gaseous - liquid
see pressure range
130
opening 30-3000 closing 30-3000
direct mounted pilot valve 60
direct mounted pilot valve 50
power consumption
The valves‘ technical design is based
on media and application requirements.
This can lead to deviations from the general
specifications shown on the data sheet with
regards to the design, sealing materials and
characteristics.
protection
energized duty rating
connection
additional equipment
optional
max. temperature
If order or application specifications are
incomplete or imprecise there exists a risk of
an incorrect technical design of the valve for
the required application. As a consequence,
the physical and / or chemical properties of
the materials or seals used, may not be suitable for the intended application.
explosion proof
kg
9,0
options
Un
Un
DC
AC
IP 65 (P54)
ED
DC 24V
special voltage upon request
special voltage upon request
AC 230V 50 Hz
4,8 W
2,5 W
pick up 11,0 VA holding 8,5 VA
acc. DIN 40 050
100%
plug acc. DIN EN 175301-803 form B, 4 positions x 90° / wire diameter 6-8 mm
illuminated plug with varistor
M12x1
connector acc. DESINA
connector acc. VDMA
media
60°C
ambient
50°C
EEx m II T5 nominal voltage Un
direct current 24 V
3,25 W
alternating current 230 V 50 Hz 2,90 W
power consumption
pneumatic specifications
actuation pressure range
air consumption
cycle speed
control
actuator ports
remote mounted pilot valve outside temperature range of media max.150°C
inductive
electrical specifications
nominal voltage
options
bar
4-10
cm³/stroke 7
main valve speed variable by throttles on pilot valve
preferably 5/2-way pilot valve
2/4
G 1/8
hydraulic specifications
options
actuation pressure range
by media
control
actuator ports
■ specifications not highlighted are standard
specifications highlighted in grey are optional
Gottfried-Müller-Str. 1
2
A
valve seat synthetic resin on metal
seal materials NBR
•
b
a b
design pressure balanced, with spring return
body materials ① brass
②
Above stated body materials refer to
the valve port connections that get in contact with the media only!
müller co-ax ag
B
a
•
D-74670 Forchtenberg
•
Germany
•
fon +49(0)7947/828-0
•
fax +49(0)7947/828-11
•
Email info@co-ax.com
type PCD-H 10
function:
NC
closed when not energized
64,5
101
G
A
B
63
86
111
136
G
M8x10
275
29
G 1/8
4X
91,5
28
2Y
82,5
M5 vent bore
G 1/8
34,5
79
SW 80
type PCD-H 10
function:
NO
open when not energized
64,5
101
275
B
A
pneumatic actuation (separately)
G
G
29
G 1/8
4X
91,5
28
2Y
82,5
M5 vent bore
G 1/8
34,5
79
4 2
12
86
111
M8x10
136
14
5/2-way-pilot valve
flow rate 350 l/min
pressure range 3-10 bar
G 1/8
63
5 13
SW 80