3-Part-Spec-Crawford-SP2024 (, 721 kB)

www.assaabloyentrrance.us
SECTION 08360
Crawford SP2024 –SECTIONAL OVERHEAD DOORS
Display hidden notes to specifier by using “Tools”/”Options”/“View”/”Hidden Text” in MS Word 2003 or
“Word Options”/”Display”/Hidden Text” in MS Word 2007, or “File” / ”Options” / ”Display/ ”Hidden Text” in
MS Word 2010 & 2013.
PART 1 GENERAL
1.1
1.2
1.3
1.4
SECTION INCLUDES
A.
Insulated Steel Doors
B.
Commercial Steel Doors
C.
Aluminum Doors
D.
Track and Framing
E.
Hardware
RELATED SECTIONS
A.
Section 04810 - Unit Masonry Assemblies: Prepared opening in masonry.
B.
Section 05500 – Metal Fabrications: - Steel framed door openings.
C.
Section 06100 – Rough Carpentry: Wood framing and blocking for door opening.
D.
Section 07900 - Joint Sealers: Perimeter sealant and backup materials.
E.
Section 08710 - Door Hardware: Cylinder locks.
F.
Section 11150 - Parking Control Equipment: Remote door control.
G.
Division 16 Sections: Electrical service and connections for powered operators.
REFERENCES
A.
ASTM A 653/A 653M – Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron
Alloy-Coated (Galvannealed) by the Hot-Dip Process.
B.
ASTM B 209/209M – Specification for Aluminum and Aluminum-Alloy Sheet and Plate.
C.
ASTM B 221/221M – Specification for Aluminum and Aluminum-Alloy Extruded Bars, Rods,
Wire, Profiles and Tubes.
D.
ANSI/DASMA 102-2011.
SUBMITTALS
A.
Submit under provisions of Section 01300.
B.
Product Data: Manufacturer's data sheets on each product to be used, including:
Technical data subject to change without notice.
1.01503
1.
2.
3.
4.
5.
1.5
C.
Shop Drawings: Include opening dimensions and required tolerances, connection details,
anchorage spacing, hardware locations, and installation details.
D.
Selection Samples: For each finish product specified, two complete sets of color chips
representing manufacturer's full range of available colors and patterns.
E.
Verification Samples: For each finish product specified, two samples, minimum size 6
inches (150 mm) square, representing actual product, color, and patterns.
WIND PERFORMANCE REQUIREMENTS
A.
1.6
1.7
A.
Manufacturer Qualifications: Company specializing in manufacturing the types of doors
specified in this section with minimum five years documented experience.
B.
Installer Qualifications: Installation to be by qualified installer in accordance with the
manufacturer’s installation instructions.
DELIVERY, STORAGE, AND HANDLING
Store products in manufacturer's unopened packaging until ready for installation.
PROJECT CONDITIONS
A.
1.9
Design doors to withstand positive and negative wind loads as calculated in accordance with
applicable governing building codes.
QUALITY ASSURANCE
A.
1.8
Preparation instructions and recommendations.
Storage and handling requirements and recommendations.
Installation methods.
Operation and maintenance data.
Nameplate data and ratings for motors.
Maintain environmental conditions (temperature, humidity, and ventilation) within limits
recommended by manufacturer for optimum results. Do not install products under
environmental conditions outside manufacturer's absolute limits.
WARRANTY
A.
Paint finish: 10-year warranty against rust through from cracking, checking or peeling of the
paint finish.
PART 2 PRODUCTS
2.1
2.2
MANUFACTURERS
A.
Acceptable Manufacturer: ASSA ABLOY Entrance Systems; 165 Carriage Court, WinstonSalem, NC 27105. ASD. Tel: (844) 232-4676. Email: us.crawford@assaabloy.com
Website: www.assaabloyentrance.us
B.
Substitutions: Not permitted.
C.
Requests for substitutions will be considered in accordance with provisions of Section
01600.
OVERHEAD DOORS - GENERAL
Technical data subject to change without notice.
1.01503
A.
Provide each door with door sections, brackets, tracks, counterbalance mechanisms and
hardware to suit the opening and headroom available.
B.
Hardware:
1.
Minimum of 14 gauge galvanized steel hinges and 13 gauge galvanized steel track
brackets.
2.
Rollers have 10 ball bearings with casehardened inner and outer races.
3.
Sliding end stile locking device provided with spring-loaded bolt for inside operation
only.
4.
Doors 16 feet 4 inches (5102 mm) and wider provided with double end hinges and
stiles and long stem rollers.
C.
Tracks: 2 inches (51 mm) or 3 inches (76 mm) as required.
1.
2.
3.
4.
5.
6.
7.
2.3
Vertical Track:
a.
2 inch vertical track 17 or 19-gauge minimum galvanized steel, inclined using
adjustable brackets to assure weather tight closure at the jambs.
b.
3 inch vertical track 12-gauge minimum galvanized steel inclined using
adjustable tapered reverse angle to assure a weather tight closure at the
jambs.
Horizontal tracks
a.
2 inch 16-gauge minimum galvanized steel, reinforced with 13-gauge
galvanized steel angles as required by door size and weight.
b.
3 inch 12-gauge minimum galvanized steel, reinforced with 11-gauge
galvanized steel angles
Provide standard lift track as indicated.
Provide vertical lift track as indicated.
Provide high lift track as indicated.
Provide follow-the- roof-pitch tracks as indicated.
Provide low headroom tracks as indicated.
D.
Spring Counterbalance: Torsion springs for door counter-balance mounted on a continuous
cross header shaft. Springs to be oil tempered, helical wound and custom computed for
each door. Cable drums to be die cast aluminum. Galvanized lift cable to provide minimum
safety factor of five to one. Springs to comply with ANSI/DASMA 102-2011 as follows:
1.
Standard Cycle Spring: 10,000 cycles.
2.
High Cycle Spring: 25,000 cycles.
3.
High Cycle Spring: 50,000 cycles.
4.
High Cycle Spring: 100,000 cycles.
E.
Handle: Galvanized steel step plate/lift handle provided on inside and outside of bottom
section.
F.
Lock: Standard interior sliding end stile lock with hole to receive padlock.
1.
Lock: 5 pin cylinder lock interior lock bar and outside key.
G.
Mounting: Continuous reverse angle mounting for steel jambs.
H.
Mounting: Bracket mounting for wood jambs.
I.
Exhaust port: Installed in bottom sections. Connecting tube from vehicles by others.
COMMERCIAL STEEL DOORS
A.
Crawford SP2024 commercial ribbed steel door with smooth exterior finish.
Technical data subject to change without notice.
1.01503
1.
2.
3.
4.
5.
6.
7.
8.
Door Size: As indicated on the Drawings.
Door Sections: 2 inches (51 mm) thick roll formed from commercial quality hot dipped
galvanized 24 gauge steel per A653-94.
a.
Each section to have two deep ribs and six shallow ribs and a tongue and
groove joint for a weather tight seal between sections.
b.
End and intermediate stiles to be formed from 0.042 inch (1.1 mm) 19 gauge
minimum galvanized steel and engineered for quick hardware attachment
through prepunched extruded holes.
c.
All stiles to be fastened to the section using the TOG-L-LOC joining system.
Finish: Door exterior to be pre-painted steel consisting of a hot dipped galvanized
coating applied to the base metal, a 0.2 mil baked on prime coat and an 0.8 mil baked
on polyester top coat. The interior coat to be 0.2 mil primer with a 0.3 mil white top
coat.
a.
Exterior Color: Commercial White.
b.
Exterior Color: Commercial Brown.
c.
Exterior Color: Black.
Window Lites: Framed lites 24 by 6 inches (610 by 152 mm) with Plexiglas glazing in
a screw together PVC frame.
Window Lites: Framed lites 24 by 12 inches (610 by 305 mm) with single or insulated
Plexiglas glazing in a screw together PVC frame.
Full View Sections: Full view aluminum sections
a.
Clear Anodized Aluminum Finish.
b.
Dark Bronze Anodized Aluminum Finish.
c.
Black Anodized Aluminum Finish.
d.
White Powder Coated Aluminum Finish.
Insulation:
a.
CFC-free expanded polystyrene (EPS) insulation with a vinyl faced backer on
door interior.
b.
CFC-free expanded polystyrene (EPS) insulation with a steel backer on door
interior
Operation
a.
Manual Operation: Pull rope.
b.
Manual Operation: Chain hoist.
c.
Electric Motor Operation: Provide UL listed electric operator, size and type as
recommended by manufacturer. Operator shall meet UL325-2010 requirements
for continuous monitoring of safety devices.
1)
Primary Monitored Entrapment Protection Entrapment Protection:
(Required for momentary contact including radio control operation)
(a)
Electric sensing edge monitored to meet UL 325-2010.
(b)
Photoelectric sensors monitored to meet UL 325-2010.
2)
Ancillary Entrapment Protection (optional, used to supplement primary
entrapment protection or basic constant-pressure-to-close):
(a)
Pneumatic Sensing Edge up to 22’
(b)
Retro-Reflective photo sensor
3)
Operator Control Mounting:
(a)
Flush Mount
(b)
Surface Mount
4)
Operator Control Operation
(a)
Push-button operated control stations with open, close, and stop
buttons.
(b)
Key operated control stations with open, close, and stop buttons.
(c)
Push-button and key operated control stations with open, close,
and stop buttons.
5)
Operator Control Location
(a)
Interior location
(b)
Exterior location
Technical data subject to change without notice.
1.01503
6)
2.4
(c)
Both interior and exterior location
Special Operation:
(a)
Vehicle detector operation
(b)
Radio control operation
(c)
Card reader control
(d)
Photocell operation
(e)
Door timer operation
(f)
Explosion and dust ignition proof control wiring
FABRICATION
1.
Standard maximum width: Crawford SP2024 up to 24 feet 2 inches width (7.4m).
a.
Galvanized struts (truss bars): Provide on all doors 14 feet 3 inches (4.3 m) and
wider to prevent deflection of no more than 1/120 of the spanned width when in
the open position
b.
Standard maximum height: Crawford SP2024 up to 24 feet 1 inch height
(7.3m).
PART 3 EXECUTION
3.1
3.2
3.3
3.4
EXAMINATION
A.
Do not begin installation until substrates have been properly prepared.
B.
Verify wall openings are ready to receive work and opening dimensions and tolerances are
within specified limits.
PREPARATION
A.
Clean surfaces thoroughly prior to installation.
B.
Prepare opening to permit correct installation of door unit to perimeter air and vapor barrier
seal.
INSTALLATION
A.
Install in accordance with manufacturer's instructions. Doors to be interior face mounted on a
prepared surface.
B.
Anchor assembly to wall construction and building framing without distortion.
C.
Securely brace door tracks suspended from structure. Secure tracks to structural members
or solid backing only.
D.
Fit and align door assembly, tracks and operating hardware.
E.
Install perimeter weatherstripping.
F.
Adjust door assembly to smooth operation and in full contact with weatherstripping.
CLEANING
A.
Clean doors, frames and glass.
G.
Remove labels and visible markings.
Technical data subject to change without notice.
1.01503
3.5
PROTECTION
A.
Protect installed products until completion of project.
B.
Touch-up, repair or replace damaged products before Substantial Completion.
END OF SECTION
Technical data subject to change without notice.
1.01503