HT-SMC

CANbus Digital Output
Pressure Transducers
& Transmitters
HT-SMC Series
High accuracy & reliability
Ranges 1 bar to 2,000 bar
CANopen 2.0A/2.0B interface
Wide choice of connectors
Temperature -40°C + 125°C
Compact and rugged design
Plant Engineering
For digital process control systems an integrated CANbus pressure
measurement solution. This sensor features a CANopen interface
(DIN ISO 11898) and CAN controller compliant with CANopen
2.0A protocol. CANopen 2.0B is also available. This high speed
interface permits data sampling rates of up to 1 Mbit/sec.
Discover more at www.hydrotechnik.co.uk
Industrial machinery
Agricultural machinery
Hydraulics and Pneumatics
Automotive
Visit us at www.ukflowtechnik.com
Connectors*
CANbus Digital Output
Pressure Transducers & Transmittersmale socket
M12x1 (S 763)
HT-SMC Series
TECHNICAL SPECIFICATIONS
Pressure Measurement
Measuring range *(bar)
1
1.6
2
2.5
4
6
10
Overload pressure
6
6
6
6
10
20
20
Burst pressure
9
9
9
9
15
30
30
Measuring range (bar)
16
20
25
40
60
100
160
Overload pressure
40
40
100
100
200
200
400
Burst pressure
60
60
150
150
300
300
400
Measuring range (bar)
200
250
400
600
1000
1600
600
Overload pressure
400
750
750
840
1200
2400
2400
Burst pressure
600
1000
1000
1050
1500
3000
3000
*Gauge ranges shown - vacuum and absolute ranges available on request
Electrical
Standard
Option
CANopen interface acc to DIN ISO 11898
CAN 2.0A
CAN 2.0B
Supply voltage
2<30 mA
2<30 mA
HT-SMC
with
male
socket
M12-connector
M12x1 (S 763)
• M
edia temperature range:
-40°C to +125°C
• C
ompensated temperature range:
-20°C to +85°C
• A
mbient temperature range:
-40°C to +105°C
Performance
• A
ccuracy: Non-linearity, hysteresis and
non-repeatability at room temperature
according to IEC 61298-2
(or BSFL/Best Fit Straight Line)
<0.5% FS range (<0.25% BFSL)
Optional <0.25% FS range
(<0.15% BFSL)
• Temperature effects: Zero/Span typical
thermal coefficients <0.15%
FS range/ 10°C
• Total Error Band: 2% FS from room
temperature to -40°C or +105°C
• Long term stability: <0.1% FS range/year
• Response time: <1mS (from 10% to
90% FS range)
• Vibration resistance: 20g (according to IEC
68-2-6 and IEC 68-2-36)
• Shock resistance: 1000g (according to IEC
to 68-2-32)
Physical
• Material: body - stainless steel
•
•
•
•
pressure inlet port - stainless steel
(stainless steel and silicon for absolute
pressure ranges)
P
rocess connection: G 1/4 A, G 1/4
B, 1/4NPT, G1/2 B
Other connections available on request
E lectrical connection: integral cable,
M12 x 1 male socket
Other connections available on request
W
eight: approximately 80-120g
(dependent upon configuration)
Ingress protection: IP65 (for
connector versions with their mating
plug fitted)
Male socket
M12x1 (S763)
Options
(1) Improved accuracy <0.25% FS
(<0.15% BFSL)
(2) additional cable
(per metre - specify length)
For further options or customised products
please contact us.
Related products
Hydrotechnik manufactures a wide
range of sensors, test and measurement
equipment.
Ordering Information
1. Pressure range: e.g. 10 bar gauge
2. Process connection: e.g. G 1/4 A
3. Electrical connection: e.g. M12 x 1
4. Options required: e.g. improved accuracy
Contact us for further information or
visit www.hydrotechnik.co.uk
Continuing development can necessitate
specification changes without notice
1 Central Park, Lenton Lane, Nottingham, NG7 2NR
t: 0115 9003 550 e: sales@hydrotechnik.co.uk
www.hydrotechnik.co.uk
HYDROTECHNIK
UK LIMITED