Center Line Installation and Maintenance Instructions (Publication # CV

Add to my manuals
16 Pages

advertisement

Center Line Installation and Maintenance Instructions (Publication # CV | Manualzz

INSTALLATION and

MAINTENANCE

INSTRUCTIONS

MANUAL AND AUTOMATED

RESILIENT SEAT BUTTERFLY VALVES

CONTENTS

Introduction

Valve Description................................................................................................................................... 3

Valve Design Features .......................................................................................................................... 3

Flange and Pipe Schedule Compatibility ............................................................................................... 3

Gasket Compatibility.............................................................................................................................. 3

Operating Pressures.............................................................................................................................. 3

Product Identification ............................................................................................................................. 3

Installation Recommendations

Valve Ratings ........................................................................................................................................ 4

Valve Seat Position ............................................................................................................................... 4

Disc Clearances .................................................................................................................................... 4

Opening Rotation................................................................................................................................... 4

Installation Position................................................................................................................................ 4

Valve and Flange Preparation ............................................................................................................... 4

Installation Tools.................................................................................................................................... 4

Required Bolting .................................................................................................................................... 4

Unpacking and Storage Instructions...................................................................................................... 4

Pre-Installation Procedure ..................................................................................................................... 5

Valve Installation Procedure ............................................................................................................ 5 & 6

Flange Bolting Recommendations......................................................................................................... 7

Maintenance Instructions

Safety Precautions ................................................................................................................................ 8

General Maintenance ............................................................................................................................ 8

Butterfly Valve Disassembly .................................................................................................................. 8

Butterfly Valve Assembly ................................................................................................................. 8 & 9

Check Valve Disassembly ..................................................................................................................... 9

Check Valve Assembly ........................................................................................................................ 10

Ratchet Handle Mounting Procedure .................................................................................................. 10

Manual Gear Mounting Procedure ...................................................................................................... 10

Remote Actuator (Male Drive) Mounting Procedure............................................................................ 10

Remote Actuator (Female Drive) Mounting Procedure ....................................................................... 10

Parts List.............................................................................................................................................. 11

Centerline Figure Number System ................................................................................................. 12-16

2

CENTER LINE

9860 Johnson Road, Montgomery, TX 77316

936/588-4447

FAX 936/588-4427

INTRODUCTION

SECTION 1

Valve Description

The Center Line Resilient Seat Butterfly Valve (RSBFV) is designed for use in ASME Class 150 piping systems and is available in both Wafer and Lug style body designs. The standard valve size range available is as follows:

• Series 200 200 psi Standard BFV 2" to 12"

150 psi Standard BFV 14" to 36"

• Series 225 285 psi BFV 2" to 24"

• Series 250 285 psi BFV (SS & CS) 2" to 24"

• Series 300 Two-piece Stem 2" to 12"

• Series 800 Check Valve 2" to 24"

Center Line Series 225 Butterfly Valve are also available with an ASME Class 300 bolt pattern for Lug bodies of sizes

2" through 12".

Valve Design Features

• The unique Center Line seat and disc design insures positive valve sealing while maintaining low seating torque.

• All Center Line Butterfly Valve discs are precision machined to a half ball profile, providing a precise disc to seat relationship.

• Center Line's cartridge style seat incorporates an elastomer bonded to a phenolic stabilizing ring, eliminating elastomer movement and reducing seat tearing or fatiguing due to bunching.

• Center Line's basic three bushing design completely isolates the valve shaft from the body, resulting in increased control of the valve disc, lower valve seating torque, and longer valve life.

• The Center Line cartridge seat has a much smaller mass of elastomer than traditional boot seat designs, limiting seat swell and the accompaning variations in seating torque.

Flange and Pipe Schedule Compatibility

The Center Line RSBFV is designed to fit between standard piping flanges as follows:

• ASME 125 Cast Iron Flanges (All Sizes)

• ASME 150 Steel Flanges, Schedule 40 (All Sizes)

• ASME 150 Steel Flanges, Schedule 80 (2" to 10")

• ASME 300 Steel Flanges, Schedule 40 (Series 225 Lug,

2" to 12" only).

When using Schedule 80 piping, special care must be taken to make sure the valve is centered between the flanges to prevent damage to the disc edge when opening or closing.

Gasket Compatibility

In the Center Line butterfly valve and check valve design, the elastomer seat extends beyond the valve face and provides a leakproof seal between the valve and the mating pipe flange faces. Gaskets are not needed and should not be used when the valve is installed between standard weld neck or slip-on type flanges.

Operating Pressures

All Center Line Series 200 and 205 Butterfly Valves are rated at 200 psi bubble tight shut-off for sizes 2" to 12" and 150 psi bubble tight shut-off for sizes 14" and larger. Center Line

Series 225 Butterfly Valves are rated for bubble tight shutoff at 285 psi, while Series 400 Damper Valves which are not designed for bubble tight shut-off have a body working pressure of 200 psi. Center Line Series 800 Check Valves are rated at a minimum pressure differential of 25 psi and a maximum pressure differential of 150 psi for bubble tight shut-off.

Product Identification

Each Center Line valve has an identification tag attached to the valve body. Information on this tag includes the valve

Series Number, materials of construction for the Body, Disc, and Seat, and the valve Pressure Rating.

SERIES

BODY

DISC

SEAT

RATING

CENTER LINE

PSI

9860 Johnson Road, Montgomery, TX 77316

936/588-4447

FAX 936/588-4427

CENTER LINE

3

INSTALLATION RECOMMENDATIONS

SECTION 2

Valve Ratings

Center Line valves are intended for use at the pressure indicated on the nameplate attached to each individual valve. Check the valve operating temperature and pressure rating before proceeding with installation.

Valve and Flange Preparation

If the valve and mating pipe are properly prepared for installation, future problems can be avoided. All valve seat and pipe flange faces should be free of dirt, grit, dents, or surface irregularities which may disrupt flange sealing and cause external leakage. The valve disc sealing surface should also be inspected to eliminate any dirt or foreign material that will adversely affect the operation of the valve.

Valve Seat Position

All Center Line butterfly valves are completely bi-directional, so installation is not dependent on seat orientation. For Center

Line Series 800 Check Valves, every effort should be made for installation with backflow protection (no flow) into the seat side of the valve. Bubble-tight shutoff will be achieved in this orientation with 25 to 150 psi ∆P across the valve.

Disc Clearances

Prior to installing the valve, it is important to make sure the

ID of the pipe and the pipe flanges are large enough to allow the disc edge to swing into the opening without interference.

Damage to the disc edge can severly affect the performance of the valve. Flange and pipe schedule compatibility for

Center Line valves is shown in Section 1 of this manual.

Opening Rotation

The Center Line valve disc can rotate 360° without damaging the valve or elastomer seat. The valve is designed to open with either clockwise or counterclockwise rotation of the shaft.

Installation Position

To prevent damage to the disc and seat during installation, the valve disc should be slightly open but not extending beyond the valve liner face. Positioning the disc in this

“almost closed” position will reduce seat interference and initial torque build-up during valve installation.

In general, it is preferable to install RSBFV's with the shaft in a horizontal orientation. In this position, shaft and disc weights are evenly distributed, minimizing seat wear.

Additionally, any foreign matter which may accumulate at the bottom of the disc and shaft is effectively removed each time the valve is opened.

Center Line butterfly valves are designed to operate between two flanges. If the valve installation calls for the use of one pipe flange only, a Lug style valve with Dead End

Service feature must be used.

Installation Tools

The only tool required in the installation of a Center Line

RSBFV is a wrench suitable for tightening the flange bolts and/or nuts required to secure the valve in-line. A hoist may be required to help manipulate valves 10" and larger. Smaller sized valves can usually be installed by hand. Temporary pipe supports may be used to keep mating flange faces parallel in order to aid in valve installation.

Required Bolting

The table outlined on Page 7 is furnished to provide information regarding the size, type, and quantity of bolting recommended for the installation of Center Line RSBFV's. This table is intended for use as a planning and procurement guide. All recommendations are based on pipe flanges in accordance with ASME 125/150 specifications. Flange bolting is not included with the valve shipment.

Unpacking and Storage Instructions

1.

2.

3.

4.

5.

6.

7.

8.

Check the packing list against the valve received to verify that the size, material, and trim are correct.

Check to make sure that the valve and operator were not damaged during shipment.

When lifting the valve, take care to avoid damage to the flange faces, disc sealing edge, or operator.

If the valve is to be stored before being installed, it should be protected from harsh environmental conditions.

Store the valve with the disc in the “almost closed” position to protect the sealing edge and the seat.

Keep the valve in a clean location, away from dirt, debris and corrosive materials.

Keep the valve in a dry area with the flanges protected and on a suitable skid or pallet.

Keep the valve in a cool location if possible, out of direct sunlight.

4

CENTER LINE

9860 Johnson Road, Montgomery, TX 77316

936/588-4447

FAX 936/588-4427

INSTALLATION RECOMMENDATIONS

Pre-Installation Procedure

1.

2.

3.

4.

Remove any protective flange covers from the valve.

Inspect the valve to be certain the waterway is free from dirt and foreign matter. Be certain the adjoining pipeline is free from any foreign material such as rust and pipe scale or welding slag that could damage the seat and disc sealing surfaces.

Any actuator should be mounted on the valve prior to installation to facilitate proper alignment of the disc in the valve seat.

Check the valve identification tag for materials, and operating pressure to be sure they are correct for the application.

WARNING!

Personal injury or property damage may result if the valve is installed where service conditions could exceed the valve ratings.

5.

Check the flange bolts or studs for proper size, threading, and length.

Valve Installation Procedure

Position the connecting pipe flanges in the line to insure proper alignment prior to valve installation. Spread the pipe flanges apart enough to allow the valve body to be located between the flanges without actually contacting the flange surfaces (See Figure 1.) Exercise particular care in handling the valve so as to prevent possible damage to the disc or seat faces.

1. For Wafer style valves: a. Place the valve between the flanges.

b. Loosely install the two upper and lower flange bolts that pass through the body alignment holes.

c. Install the remaining flange bolts, shifting the valve as necessary to permit the bolts to pass by the valve body. Hand tighten all bolts as necessary.

Figure 1-Initial Installation of Valve

For Lug style valves: a. Place the valve between the flanges.

b. Install all bolts between the valve and the mating flanges. Hand tighten bolts as necessary.

For Check Valves: a. Note the opening direction of the disc for proper valve orientation.

b. Place the valve between the flanges using the four

(4) alignment holes provided.

c. Install the remaining flange bolts, shifting the valve as necessary to permit the bolts to pass by the valve body. Hand tighten bolts as necessary.

2.

Before completing the tightening of any bolts, the valve should be centered between the flanges and then carefully opened and closed to insure free, unobstructed disc movement (See Figure 2.)

3.

Using the sequence shown in Figure 3, tighten the flange bolts evenly to assure uniform compression.

4.

If an actuator is to be used, air hoses or electricity should be connected to the unit as specified by the actuator manufacturer.

5.

Cycle the valve to the fully open position, then back to the fully closed position, checking the actuator travel stop settings for proper disc alignment. The valve should be operated to assure that no binding is taking place.

6.

The valve is now ready for operation.

Remember: Install the valve with the disc in the “ALMOST CLOSED” position.

Do not use any flange gaskets.

Incorrect

Disc opened beyond valve body face. Pipe flanges not spread sufficiently.

Correct

Disc positioned in the almost closed position.

Pipe flange spread allows sufficient room for valve.

9860 Johnson Road, Montgomery, TX 77316

936/588-4447

FAX 936/588-4427

CENTER LINE

5

INSTALLATION RECOMMENDATIONS

Figure 2-Centering and Flanging of Valve

Gasket

Incorrect

Disc in closed position.

Gaskets installed between valve and mating flanges.

Correct

No flange gaskets used.

Disc in the “almost closed” position.

Figure 3-Flange Bolt Tightening Sequence

1

4

3

2

8

4

1 5

6 2

3

7

8

12

4

10

1

6 2

5

9

3

7

11

12

4

10

8

15

6

1 13

14 2

5

16

9

3

7

11

Figure 4-Final Valve Alignment and Tightening of Flange Bolts

Incorrect

Pipe Flanges mis-aligned.

Uneven torque applied to bolting.

Correct

Piping aligned.

Thread engagement even on both sides of valve.

6

CENTER LINE

9860 Johnson Road, Montgomery, TX 77316

936/588-4447

FAX 936/588-4427

INSTALLATION RECOMMENDATIONS

Flange Bolting Recommendations

Valve

Size

2"

2 1/2"

Center Line Wafer And Lug Valves, 2"-30", ASME 125/150 Bolt Pattern

Thread

Size

5/8-11

Number

Required

4

Stud Length Stud Length

Wafer B'fly (in.) Check Valve (in.)

4.750

5.125

Bolt Length

Lug B'fly (in.)

1.250

5/8-11 4 5.250

5.375

1.500

5"

6"

8"

3"

4"

10"

12"

14"

16"

18"

20" Series 200

2 0 " S e ir e s 2 2 5

24" Series 200

2 4 " S e ir e s 2 2 5

3 0 " S e ir e s 2 0 0

1-8

1-8

1 1/8-7

1 1/8-7

1 1 / 8 7

5/8-11

5/8-11

3/4-10

3/4-10

3/4-10

7/8-9

7/8-9

1 1/4-7

1 1 / 4 7

1 1 / 4 7

12

16

16

20

1 6

+ 4 e a .

20

1 6

+ 4 e a .

2 4

+ 4 e a .

8

8

8

4

8

12

12

8.250

8.750

10.000

11.250

1 1

5

.

2

.

0

5 0

0 0

12.750

1 2

5

.

7

.

2

5 0

5 0

1 3

5

.

7

.

7

5 0

5 0

5.250

5.750

6.000

6.250

6.750

7.250

7.750

12.250

11.750

13.000

14.500

5.375

6.000

6.375

7.000

8.000

8.500

9.750

15.125

2.750

2.750

3.500

4.250

4

3

.

.

2

2

5 0

5 0

4.750

4

3

.

.

7

7

5 0

5 0

4

4

.

.

5

2

0 0

5 0

1.500

1.750

1.750

2.000

2.250

2.250

2.500

25-100

25-100

25-100

50-200

50-200

Req. Torque

(Ft-lbs)

15-60

15-60

15-60

15-60

70-300

70-300

100-400

100-400

1 0 0 -

1 0 0 -

4

4

0 0

0 0

150-500

1 5 0 -

1 5 0 -

5

5

0 0

0 0

1 5 0 -

1 5 0 -

5

5

0 0

0 0

Bolting and torque recommendations are made without a warranty, and apply only to steel weld-neck or slip-on flanges.

The use of lock washers and/or lubrication with the bolting will affect stated torque values.

9860 Johnson Road, Montgomery, TX 77316

936/588-4447

FAX 936/588-4427

CENTER LINE

7

8

MAINTENANCE INSTRUCTIONS

SECTION 3

Safety Precautions

Before removing the valve from the line or loosening any bolts, it is important to verify the following conditions:

1.

2.

3.

4.

5.

Be sure the line is depressurized and drained.

Be sure of the pipeline media. Proper care should be taken for protection against toxic and/or flammable fluids.

Never remove the valve without an Operator (Manual or

Automatic) already attached to the valve shaft.

Never remove the Operator from the valve while the valve is in the pipeline under pressure.

Always be sure that the disc is in the closed position before removing the valve.

Butterfly Valve Assembly

1.

2.

3.

4.

Thoroughly clean all parts. Inspect components for any defects.

Apply a small amount of silicone grease to the inside surfaces of the body, including the upper and lower shaft holes.

Insert the shaft bushings into the body being careful not to allow intrusion into the body seat bore.

Install the seat into the center of the body, making sure the shaft holes in the seat line up with the holes in the body.

General Maintenance

The following periodic preventative maintenance practices are recommended for all Center Line Butterfly Valves.

1.

2.

3.

4.

Operate the valve from full open to full closed to assure operability.

Check flange bolting for evidence of loosening and correct as needed.

Inspect the valve and surrounding area for previous or existing leakage at flange faces or shaft connections.

Check piping and/or wiring to actuators and related equipment for looseness and correct as needed.

Bushings

Resilient Seat

5.

Completely coat the inside surfaces of the seat with silicone grease. Carefully push the disc into the seat in the open position (90 degrees to the body.) Line up the shaft holes of the disc as close as possible with the shaft holes in the seat body.

Butterfly Valve Disassembly

1.

2.

3.

4.

5.

6.

Position valve flat with the disc in the closed position.

Loosen the taper pin(s) from the valve disc using a hammer and punch.

Note: Punch should be of same size or larger diameter as small end of taper pin to avoid mushrooming of taper pin.

Remove taper pin(s) from disc. Extract the valve shaft from the body using a twisting motion.

Remove the valve disc from body making sure not to damage the seat or disc sealing edge.

Cartridge seat removal can be accomplished from either direction by applying pressure evenly on one face to push the seat through the body. If the valve is of dead end service design, remove set screws around periphery of body extending into seat prior to seat removal.

Remove shaft bushings from body as required.

Disc

CENTER LINE

9860 Johnson Road, Montgomery, TX 77316

936/588-4447

FAX 936/588-4427

MAINTENANCE INSTRUCTIONS

Butterfly Valve Assembly

(continued from page 8)

6.

Insert the shaft through the body and disc, use a twisting motion to align the keyway parallel with the disc.

Shaft

7.

8.

Insert taper pin(s) into the disc and set with two or three sharp blows. Wipe dust shield o-ring with silicone grease and place over the shaft into the top of the body.

If the valve is of dead end service design, insert set screws through the body into the seat.

Check Valve Disassembly

1.

Remove set screw (7) from the alignment body (1).

2.

Remove the valve insert (4) from the alignment body (1).

3.

Remove shaft plugs (8) from the insert with a screwdriver.

Note: Plugs are sometimes difficult to loosen. When this happens, apply heat with small torch directly to the plug for

30 seconds. Do not allow the flame to touch the elastomer face on either side of the inset.

4.

Remove the shaft (3) from the valve insert.

Note: When the stem is removed, the springs (5) behind the check plates (2) will be released. On sizes 8" to 20", these springs must be securely held to prevent recoil upon loss of tension.

5.

Remove the check valve plates (2) from the valve insert.

Note the location of the thrust washers (6). These must be replaced in the same location upon reassembly.

8

3

4

Key

O-Ring 8

1

Taper Pins

6

2

6

2

5

5

1

7

9860 Johnson Road, Montgomery, TX 77316

936/588-4447

FAX 936/588-4427

CENTER LINE

9

MAINTENANCE INSTRUCTIONS

Check Valve Assembly

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

Place valve plates (2) into the insert (4).

Replace thrust washers (6) in original location.

Install shaft (3) half way into the insert.

Pre-load first spring (5) with 1/2 turn windup. Do not unwind spring. Legs of spring should be horizontal, 180° apart.

Place spring (5) on shaft (3) and release.

Install shaft (3) just far enough to allow installation of second spring (5).

Push shaft (3) completely into insert (4).

Replace shaft plugs (8) in insert (4) with pipe thread sealant and tighten firmly.

Place insert (4) in body (1) with tapped hole in body aligned with drill point in insert.

Replace set screw (7) and tighten.

Ratchet Handle Mounting Procedure

1.

2.

3.

4.

5.

Position the disc in the closed position.

Install the ratchet plate using machine bolts, nuts and lock washers, but do not tighten the fasteners.

Install the drive key in the shaft. Tap the key into place to ensure it is fully seated in the keyway .

Install the handle so that it is parallel with the disc face.

The locking lever must be fully retracted before it will pass through the ratchet plate. Tighten the set screw in the handle against the key.

With the handle installed flush with the ratchet plate, engage the locking lever with the ratchet plate. Using the handle, adjust the position of the ratchet plate until the disc face is parallel with the valve face, then tighten the fasteners securely.

Remote Actuator (Male Drive)

Mounting Procedure

1.

2.

3.

4.

5.

6.

7.

Position the disc in the closed position.

Install the actuator mounting bracket on the valve body with the actuator mounting holes facing up-ward. Fasten the bracket securely in place with the appropriate machine bolts, nuts, and lock washers.

Install the drive key in the keyway of the shaft. Tap the key in place to insure it is fully seated.

Install the drive coupling on the shaft by lining up the proper keyway in the coupling with the key in the shaft.

Rotate the actuator shaft to the full clockwise position.

Align the drive coupling with the actuator shaft and install the actuator on the mounting bracket.

Fasten the actuator to the mounting bracket with the appropriate machine bolts and lock washers. It may be necessary to slightly rotate the actuator shaft to align the mounting holes in the actuator with the mounting bracket.

Adjust the stops in the actuator to position the face of the disc parallel with the face of the valve body in the closed position and perpendicular to the face of the valve body in the open position.

Manual Gear Mounting Procedure

1.

2.

3.

4.

5.

Position the disc in the closed position.

Install the drive key in the shaft. Tap the key into place to ensure it is fully seated.

Rotate the gear shaft to the full clockwise position. Align the keyway in the gearbox bore with the key in the shaft and slide the gearbox onto the shaft.

Fasten the gearbox to the mounting bracket with the appropriate machine bolts and lock washers. It may be necessary to rotate the gear shaft slightly to align the mounting holes in the gear with the plate.

Adjust the stops in the gearbox to position the face of the disc parallel with the face of the valve in the closed position and perpendicular to the face of the valve in the open position.

Remote Actuator (Female Drive)

Mounting Procedure

1.

2.

3.

4.

5.

6.

7.

8.

Position the disc in the closed position.

Install the actuator mounting bracket on the valve body with the actuator mounting holes facing up. Fasten the bracket securely in place with the appropriate machine bolts, nuts, and lock washers.

Install the drive key in the shaft. Tap the key in place to insure it is fully seated.

Install the drive coupling on the shaft by lining up the proper coupling keyway with the key in the shaft.

Install the drive key in the drive coupling. Tap the key in place to insure it is properly seated.

Rotate the actuator to the full clockwise position. Align the keyway in the actuator bore with the key in the drive coupling and slide the actuator on the drive coupling.

Fasten the actuator to the mounting bracket with the appropriate machine bolts and lock washers. It may be necessary to rotate the actuator slightly to align the actuator with the mounting bracket.

Adjust the stops in the actuator to position the face of

!he disc parallel with the face of the valve body in the closed position and perpendicular to the face of the valve body in the open position.

10

CENTER LINE

9860 Johnson Road, Montgomery, TX 77316

936/588-4447

FAX 936/588-4427

MAINTENANCE INSTRUCTIONS

Parts List

9

3

6

4

7

8

5

2

Series 200, 225, 250

Butterfly Valve

Item Description

1

2

Body

Disc

3* Seat

4 Shaft

5* Taper Pin

6 Key

7* O-Ring

8 Bushing

9

10

Bushing

Bushing

*Recommended Spare Parts

2

4

4

3

10

1

1

Series 800

Check Valve

Item Description

8

9

10

6

7

4

5

1 * Valve Body

2 * Liner (Molded to Item 1)

3 Shaft

Shaft Plug (Qty. 2)

Plate (Qty. 2)

Thrust Washer (Qty. 4)

Spring (Qty. 2)

Alignment Body

Set Screw

Plate Travel Stop (14" & larger only)

* Items 1 and 2 Must Be

Ordered Together.

6

5

7

7

6

10

9860 Johnson Road, Montgomery, TX 77316

936/588-4447

FAX 936/588-4427

8

Detail A

9

8

6

11

CENTER LINE

11

Center Line Series 200

Custom

Product

EXAMPLE: 02 AV02135X-D

2" 200 Wafer Series, Epoxy Coated Ductile Iron Body, 200 PSI, DI-ENP Disc, 416 SS Stem, PTFE

Bushings, EPDM liner, No Operator (Bare Stem), Custom

1 2 3 4 5 6 7 8 9

1. Size Code

2"

2½"

3"

4"

5"

6"

8"

10"

12"

14"

16"

18"

20"

24"

30"

36"

42"

05

06

08

10

02

25

03

04

12

14

16

18

20

24

30

36

42

2. Series/Style Code

200 Wafer - 2" - 30" (

200 Lug - 2" - 30" (Standard)

200 Lug - 2" - 30" DES*

200 Flanged (36" - 42")

* DES = Double Dead End Service

4. Pressure Code

200 PSI (2" - 12")

75 PSI Undercut (8 - 30" )

150 PSI (14" - 42")

125 PSI (2" - 12") PTFE liner

6

8

0

3

C

D

A

B

6. Stem/Shaft Code

416 SS

316 SS *

Monel 400

17-4 PH

* Standard with 316 SS disc only

1

4

7

9

7. Bushings Code

Bronze

PTFE

0

3

8. Seat /Liner Code

Buna-N

Abrasion Res. Buna-N

Neoprene (Black)

EPDM

Viton (275 F°) std. phenolic backing

Hypalon

Perx. Crd. Buna-N

PTFE/Buna-N**

Viton (400 F°)

EPDM (FDA)

White Buna-N (FDA)

Potable Water EPDM

White Buna-N

** 2½ & 5" not available

1

D

B

L

P

V

W

7

8

5

6

2

3

3. Body Material Code

Epoxy Coated CI (2" - 12" Standard)

Epoxy Coated DI - A536 (2"-12")

Cast Iron (14" - 30")

Ductile Iron - A536 (14" - 42" Standard)

Ductile Iron - A395 (2" - 30")

1

2

S

V

G

5. Disc Code

DI - ENP (2" - 12")

316 SS

DI - (14" - 42")

Al Brnz. (2" - 42")

Monel 400

2

4

5

6

7

9. Actuator Code

Handle

Gear Operator

No Operator

Lockable/Infinite (2" - 6")

Infinite (8")

Pneumatic Double Acting

Pnue. Spring Return - Fail Close

Pneu. Spring Return - Fail Open

Electric

Gear Operator/Memory Stop

Buried Gear w/2" Sq. Nut

2" Nut Direct to Valve Stem

Chain Wheel

10. Custom Code

Special Features

CE Marked - Non Impact Tested

D

P

PED Certification: Series 200 valve can be supplied with PED Certification from 2" - 24" only

7

8

4

6

X

3

2

5

C

D

9

G

U

12

EXAMPLE: JV52135X

Center Line Series 225

Custom

Product

225 Wafer, Ductile Iron, 285 PSI, DI-ENP, 416 SS, PTFE Bushings, EPDM liner, No Operator, Custom

1 2 3 4 5 6 7 8 9

1. Size Code

2"

2½"

3"

4"

5"

6"

8"

10"

12"

14"

16"

18"

20"

24"

12

14

16

18

20

24

05

06

08

10

02

25

03

04

2. Series/Style Code

225 Wafer (

225 Lug

225 Lug - DES*

225 Lug CL 300 BC (2" - 12" only)

225 Lug CL 300 BC - DES*

* DES = Double Dead End Service

J

K

L

M

N

3. Body Material Code

Epoxy Coated DI - A536 (2" - 12")

Ductile Iron - A536 (14" - 30")

Ductile Iron - A395

V

2

G

4. Pressure Code

200 PSI (2" - 12") DES*

285 PSI (2" - 24")

0

5

150 PSI (14" - 24") DES* 6

* DES Pressure Rating: 2" - 12" 200 CWP

14" - 24" 150 CWP

5. Disc Code

DI - ENP (2" - 12")

316 SS

DI - (14" - 24")

Al Brnz. (2" - 24")

Monel

5

6

2

4

7

6. Stem/Shaft Code

416 SS

316 SS *

Monel 400

17-4 PH

* Standard with 316 SS disc only

7

9

1

4

7. Bushings Code

PTFE (2"-24") 3

8. Seat /Liner Code

Buna-N

Neoprene (Black)

EPDM

Viton (275 F°)

Hypalon

Viton (400 F°)

EPDM (FDA) V

B

5

6

1

3

7

P

9. Actuator Code

Handle

Gear Operator

No Operator

Lockable/Infinite (2" - 6")

Pneumatic Double Acting

Pneu. Spring Return - Fail Close

Pneu. Spring Return - Fail Open

Electric

Gear Operator w/Memory Stop

Buried Gear w/2" Sq. Nut

2" Nut Direct to Valve Stem

Chain Wheel

8

9

6

7

X

3

2

5

D

U

G

C

10. Custom Code

Custom Product

CE Marked - Non Impact Tested

D

P

13

Center Line Series 250

Custom

Product

EXAMPLE: 2356135X

250 Wafer, Carbon Steel, 285 PSI, Al. Brnz, 416 SS, PTFE Bushings, EPDM liner, No Operator, Custom

1 2 3 4 5 6 7 8 9

1. Size Code

2"

2½"

3"

4"

5"

6"

8"

10"

12"

14"

16"

18"

20"

24"

12

14

16

18

20

24

05

06

08

10

02

25

03

04

2. Series/Style Code

250 Wafer

250 Lug

250 Lug-DES*

* DES = Double Dead End Service

2

4

6

6. Stem/Shaft Code

416 SS

316 SS *

Monel 400

17-4 PH

* Standard with 316 SS Disc Only

7

9

1

4

7. Bushings Code

PTFE (2"-24") 3

8. Seat /Liner Code

Buna-N

Neoprene (Black)

EPDM

Viton (275 F°)

Hypalon

PTFE/Buna-N

Viton (400 F°)

EPDM (FDA)

1

3

5

6

7

L

P

V

White Buna-N (FDA)

White Buna-N

W

B

3. Body Material Code

Carbon Steel **

316 Stainless Steel

3

4

4. Pressure Code

200 PSI (2" - 12") DES*

285 PSI (2" - 24") STANDARD

150 PSI (14" - 24") DES*

125 PSI (2" - 12") PTFE

6

8

0

5

* DES Pressure Rating: 2" - 12" 200 CWP

14" - 24" 150 CWP

9. Actuator Code

Handle

Gear Operator

No Operator

Lockable/Infinite (2" - 6")

Pneumatic Double Acting

Pneu. Spring Return Fail Close

Pneu. Spring Return Fail Open

Electric

Gear Op w/Memory Stop

Buried Gear w/2"Sq. Nut

2" Nut Direct to Valve Stem

Chain Wheel

8

9

6

7

X

3

2

5

D

U

G

C

5. Disc Code

316 SS

Al Brnz. (2" - 24")

Monel 400

4

6

7

10. Custom Code

Custom Product

CE Marked - Non Impact Tested

CE Marked - Impact Tested

D

P

C

**NOTE: Center Line Series 250 Carbon Steel valves with CE marking are good to 0° F for non-impact tested bodies and -20° F for impact tested carbon steel bodies.

14

Center Line Series 300

Custom

Product

EXAMPLE: 02 5106135X

2" 300 Wafer, Cast Iron, 200 PSI, Al.-Bronze, 416 SS, PTFE Bushings, EPDM Liner, No Operator,

Custom

1 2 3 4 5 6 7 8 9

6. Shaft Code

416 SS

316 SS

1

4

1. Size Code

2"

2½"

3"

4"

5"

6"

8"

10"

12"

05

06

08

10

12

02

25

03

04

2. Series/Style Code

300 Wafer (

300 Lug

5

3

3. Body Material Code

Epoxy Coated CI

Epoxy Coated DI (A536)

Cast Iron

Ductile Iron - A536

Carbon Steel

316 Stainless Steel

1

2

S

V

3

4

4. Pressure Code

200 PSI

125 PSI PTFE

0

8

5. Disc Code

316 SS

Al Brnz. (2" - 48")

4

6

7. Bushings Code

PTFE (2"-12") 3

8. Seat /Liner Code

Buna-N

Neoprene (Black)

EPDM

Viton (275 F°)

Hypalon

Viton (400 F°)

EPDM (FDA)

5

6

1

3

White Buna-N (FDA)

White Buna-N

7

P

V

W

B

9. Actuator Code

Handle

Gear Operator

No Operator

Lockable/Infinite (2" - 6")

Infinite (8")

Double Acting

Fail Close - SR

Fail Open - SR

Electric

Gear Op/Balancing

Chain Wheel

7

8

4

6

X

3

2

5

9

G

U

15

Center Line Series 800

Custom

Product

EXAMPLE: 02 R1654D5X

2" 800 Wafer, Cast Iron, 150 PSI, DI, 316 SS Shaft & Springs, EPDM liner, No Operator

1 2 3 4 5 6 7 8 9

1. Size Code

2"

2½"

3"

4"

5"

6"

8"

10"

12"

14"

16"

18"

20"

05

06

08

10

02

25

03

04

12

14

16

18

20

2. Series/Style Code

800 Wafer (

800 Euro

3. Body Material Code

Epoxy Coated CI

Cast Iron

None

S

1

X

4. Pressure Code

150 PSI (2" - 24") 6

5. Plate Code

316 SS

DI

Al Brnz.

Monel

6

7

4

5

6. Shaft Code

316 SS

Monel 400

4

7

7. Springs Code

316 SS

Monel 400

D

M

8. Seat /Liner Code

Buna-N

Neoprene (Black)

EPDM

Hypalon

Viton - High Temperature

5

7

1

3

0

9. Special Features Code

No Operator

CE Marked - Non Impact Tested

X

P

16

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project