10W Miniature Single Output Power Supply
DN-10 series
Features :
Universal AC input 88 - 264Vac
Installed on DIN rail TS35 / 7.5 or 15
Brown-out protection
Protections: Short circuit / Over load / Over voltage
All using 105°C long life electrolytic capacitors
High operation temperature up to 70°C
True DC OK signal output
Withstand 2G vibration test
High efficiency, long life and high reliability
3 years warranty
UL508 ( Industrial control equipment ) listed
UL1310 Class 2 Power unit / LPS pass
DN-10-12
MODEL
Output
Input
DC Voltage Range
Rated Current
Current Range
Rated Power
Ripple & Noise (max.)
Voltage Adj. Range
Voltage Tolerance
Line Regulation
Load Regulation
Setup, Rise Time
Hold Up Time (Typ.)
Voltage Range
Frequency Range
Efficiency (Typ.)
AC Current (Typ.)
Inrush Current (Typ.)
Leakage Current
Note.2
Note.3
Note.4
Over Load
Protection
Over Voltage
Envi r onment
Safety & EMC
Note.5
Others
Note
Working Temp.
Working Humidity
Storage Temp., Humidity
Temp.Coefficient
Vibration
Safety Standards
Withstand Voltage
Isolation Resistance
EMI Conduction & Radiation
Harmonic Current
EMS Immunity
DC OK signal
Connection
MTBF (MIL-HDBK-217F)
Cooling
Dimension (W*H*D)(mm)
Packing
12V
0.84A
0 ~ 0.84A
10.08W
100 mVp-p
DN-10-15
15V
0.67A
0 ~ 0.67A
10.05W
100 mVp-p
DN-10-24
24V
0.42A
0 ~ 0.42A
10.08W
120 mVp-p
10.8 ~ 13.2V
13.5 ~ 16.5V
21.6 ~ 26.4V
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
<800ms, <100ms/230Vac at full load
> 32 ms / 230VAC
>16ms / 115VAC at full load
88V ~ 264VAC
124 ~ 370VDC
47Hz ~ 63Hz
81%
81%
81%
0.23 A / 115VAC
0.17A / 230VAC
15A / 115VAC
30A / 230VAC
<1mA / 230VAC
> 102 % rated output power
Protection type : constant current limiting, automatically after fault condition is removed
115% ~ 150% rated output voltage
Protection type : latch-off mode
-20°C ~ 70°C (Refer to output load de-rating curve)
20 ~ 90% RH non-condensing
-40 ~ +85°C, 10 ~95% R.H
±0.03%/°C (0 ~ 50°C)
10 ~ 500Hz, 2G 10min./1 cycle, period for 60 min. Each along X,Y,Z axes
UL508, TUV EN60950-1 : 2006+A11, UL1310 NEC class 2 compliant
I/P - O/P:3KVAC (4242 DC) I/P - FG:1.5KVAC (2121 DC) 1 minute
I/P - O/P, I/P - FG, O/P - FG: 100M Ohms / 500VDC
EN55022 : 2006+A1:2007 Class B
EN61000-3-2:2006 Class A, EN61000-3-3:2008
EN61204-3: 2000, EN55024: 1998+A1: 2001+A2: 2003 light industry level, criteria A
Open collector. Max : 40mA
I/P 3 poles, O/P : 3 poles screw DIN terminal
562.7K HRS
Free Air convection
23x90x99
0.13kg ; 48Pcs / 7.44kg
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47 uf parallel
capacitor.
3. Tolerance: includes set up tolerance, line regulation and load regulation.
4. De-rating may be needed under low input voltages. Please check the de-rating curve for more details.
5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be
re-confirmed that it still meets EMC directives
REV. B2
10/10/19
1
10W Miniature Single Output Power Supply
DN-10 series
Mechanical Specification
Unit : mm
35
23
5 5
90
99
5 5
install DIN rail TS35 / 7.5 or TS35 / 15
Application of DC OK Active Signal
(a)5V signal
(b)LED
DC OK
(c)Relay
DC OK
R
5.1V
V-
Model
R
12V
≥1.5KΩ
15V
24V
DC OK
Model
R
Model
R
12V
≥2.4KΩ
12V
≥700Ω
≥2KΩ
15V
≥3KΩ
15V
≥700Ω
≥3.9KΩ
24V
≥4.7KΩ
24V
≥1.2KΩ
R
V-
Relay
RL
V-
Block Diagram
DC OK
DC OK
RECTIFIERS
&
FILTER
EMI
FILTER
I/P
RECTIFIERS
&
FILTER
POWER
SWITCHING
+V
-V
O.C.P
DETECTION
CIRCUIT
O.L.P.
CONTROL
O.V.P.
De-rating Curve
Load V.S Temp.
Load V.S I/P Voltage
Ta=25°C
100
100
90
Load (%)
Load (%)
80
60
80
70
60
40
50
20
-20
40
0
10
20
30
40
50
Ambient Temperature (°C)
60
70
85
100
110
120
264Vac
Input Voltage(Vac)60Hz
REV. B2
10/10/19
2