Data sheet SIK 7TE
Brine-to-water heat pump in a compact design
Order reference: SIK 7TE
Installation location: Indoors
Flow temperature max 58 °C
Casing, powder-coated
Heat pump for heating purposes for indoor installation with WPM 2007 plus
integrated control and control panel that can also be used as a wired remote control
using a wall-mounting kit (special accessory). Integrated brine components enable
the direct connection of the heat source:
- Brine circulating pump (free compression 55,000 Pa)
- Expansion vessel (8 l)
- Safety valve and pressure manometer. Sound-optimised through double
vibration-isolated compressor, insulated metal casing and solid-borne sound
insulation for direct connection to the heating system; economiser for high COPs.
Compact design with optimal DHW preparation and integrated components for easy
connection of an unmixed heating circuit:
- Heat circulating pump (free compression 47,000 Pa)
- Overflow valve
- Safety valve and pressure manometer
- Expansion vessel 24 l (must not be used for bivalent systems).
Integrated flow and return flow sensors; external sensor (standard NTC-2), dirt filter
and large-capacity breather with micro air bubble deposition for sole circuit included
in the scope of supply. Brine circuit manifold must be ordered separately.
The heat pump complies with the valid standards and safety regulations as well as the
Technical Specifications for Electrical Installations (TAB) of the electrical utility companies and
is VDE certified.
Technical data SIK 7TE
Dimplex Brine-to-water heat pump in a compact design (Low temperature)
Order reference
Set-up / Colour
Temperature operating limits for heating water / Brine
Temperature operating limits for brine
Heat output / COP at B0/W50*
Heat output / COP at B0/W35*
Electrical nominal power consumption at B0/W35
Refrigerant R407C
Flow rate (heat source) at ext. pressure differential
Heating water flow rate with an int. pressure
differential of
Dimensions (W x D x H)**
Weight (incl. packing)
Control voltage
Supply voltage
Starting current with soft starter
Fuse
Device connections for heating
Device connections for heat source
SIK 7TE
kW/kW/kW
kg
m³/h / Pa
m³/h / Pa
Indoors / White (similar to RAL 9003)
58 °C / -5 °C
-5 °C to 25 °C
6,70 / 2,90
6,90 / 4,30
1,60
1,50
1.7 / 10000
0.60 / 2500
mm
kg
V
A
A
652 x 688 x 1110
179
230
3/PE~400V, 50 Hz
30
16
1 1/4"
1 1/4"
* The specified values have the following meaning, e.g. B0/W35: heat source temperature 0 °C, heat outlet temperature 35 °C.
** Please note that additional space is required for pipe connections, operation and maintenance.
Glen Dimplex Deutschland GmbH
Dimplex Division
Am Goldenen Feld 18
95326 Kulmbach
Page 1/5
Subject to change and errors!
E-mail: dimplex@dimplex.de
Internet: www.dimplex.de
Internet: 26.07.2007
Phone: +49 (0)9221 709-201
Fax: +49 (0)9221 709-339
System accessories SIK 7TE
Description
Order ref.
Article
number
Sample
item
SIK 7TE
SYL 250
352810
352260
1
1
AP SVT
SVT 200
SVT 300
SVT 400
SWPR 500
AFN 825
WT 733
348900
348910
348920
348930
337500
328610
349010
1
PSP 100E
CTHK 631
CTHK 632
CTHK 633
CTHK 634
CTHK 635
VSH KS
VSW KS
PSW 200
PSW 500
HDLR 450
HCT 300
HL 16SK
HL 26SK
HL 36SK
353360
336180
335910
322140
322150
322160
343110
343120
339830
339210
337450
351210
351780
351790
351800
1
WWSP 229E
WWSP 332
FLH 60
FLHU 70
FLH 25M
SVK 852
SST 25
WWSP 880
WWSP 442E
WWSP 900
PWS 332
UP 60
UP 80
KRRV 003
353380
346610
338060
338070
349430
326660
348430
337880
353370
339220
348620
340300
340310
322070
PKS 14
342460
RBG WPM
FWPM 470
RDS
LDS
LDS USB
339700
337470
353790
353770
353780
RKS WPM
342220
RTK 501
RTK 501 U
343080
350960
TPW WPM
350970
IN 01 WP
341750
Item
Price
Heat pumps
Brine-to-water heat pump in a compact design
Elasticated sound insulation underlay strips
Heat source accessories
Brine circuit manifold connection package
2-way brine circuit manifold
3-way brine circuit manifold
4-way brine circuit manifold
Brine circuit low-pressure switch
Brine circuit antifreeze (20 l)
Plate heat exchanger using water as heat source in case of pollution
1
3
Hydraulic accessories
Built-under buffer tank (100 l) for SI(K) 5-14
2 kW immersion heater for back-up heating
2.9 kW immersion heater for back-up heating
4.5 kW immersion heater for back-up heating
6 kW immersion heater for back-up heating
7.5 kW immersion heater for back-up heating
Compact brine heat pump connection set
Hot water connection set for compact brine heat pump
Floor-mounted buffer tank (200 l)*
Universal buffer tank (500 l)*
Immersion heater pipe assembly*
3 kW radiator
Fan convector for heating/cooling with external thermostat*
Fan convector for heating/cooling with external thermostat*
Fan convector for heating/cooling with external thermostat*
1
1
DHW preparation accessories
Built-under buffer tank (200 l) for SIK 7 - SIK 9*
Hot water cylinder (300 l) with temperature sensor
6 kW flange heater for hot water cylinder
2/2.7/4 kW flange heater for hot water cylinder
Flange heater for hot water cylinder 230 V/2.5 kW
Safety valve combination
Solar station for hot water
Hot water cylinder (400 l) with temperature sensor*
Design hot water cylinder (400 l)*
Hot water cylinder (500 l) with temperature sensor*
Combination cylinder for heating and DHW preparation*
Circulating pump for main heat pump circuit
Circulating pump for main heat pump circuit
Thermostat for heating and domestic hot water
1
1
1
Accessories for passive cooling
Passive cooling station with cooling controller*
Control accessories
Swimming pool / remote fault indicator relay module
Heat pump manager remote control*
Remote diagnostics hardware package
Remote diagnostics hardware package (serial)
Remote diagnostics hardware package (USB)
Control accessories (cooling)
Room climate control system for temperature and humidity
measurement
Heating/cooling on/off room temperature controller*
Heating/cooling on-off room temperature controller in flat switch
mounting frame for flush mounting*
Extended dew point monitoring*
Start-up (no discount available)
Heat pump (heating only) start-up
1
* Other specific accessories available / required
Glen Dimplex Deutschland GmbH
Dimplex Division
Am Goldenen Feld 18
95326 Kulmbach
Page 2/5
Subject to change and errors!
E-mail: dimplex@dimplex.de
Internet: www.dimplex.de
Internet: 26.07.2007
Phone: +49 (0)9221 709-201
Fax: +49 (0)9221 709-339
System accessories SIK 7TE
Notes:
The heat source accessories are designed for ground heat collectors according to the project planning documentation. The free compression must be
checked if the dimensions deviate or if borehole heat exchangers are used. In combination with borehole heat exchangers, passive cooling station and
room climate control station enable silent cooling via panel heating systems.
Important information:
The combination of the components and the quantities indicated represent a non-binding sample system, which needs to be tested and individually
adapted as required. Pump dimensioning must be reviewed according to the pressure loss of the system and the minimum heating water flow rate of
the heat pump.
Glen Dimplex Deutschland GmbH
Dimplex Division
Am Goldenen Feld 18
95326 Kulmbach
Page 3/5
Subject to change and errors!
E-mail: dimplex@dimplex.de
Internet: www.dimplex.de
Internet: 26.07.2007
Phone: +49 (0)9221 709-201
Fax: +49 (0)9221 709-339
Brine-to-water heat pump, Integration Diagram, Heat pump and immersion heater
SELECTED STEPS:
1. Brine-to-water heat pump
2. Compact design for quick and easy installation
3. Heat pump and immersion heater
4. Overflow valve
5. 1 heating circuit for a panel or radiator heating system
6. Without cooling
7. DHW with heat pump and flange heating for thermal disinfection
8. Heat pump manager with external temperature control
Note:
The given hydraulic integration
schematic is a schematic
representation of the key components
and serves as an aid for planning your
customized system. It does not contain
all the required safety devices, the
components needed to maintain
constant pressure, or any other
additional valves which may be
required for maintenance and service
work as stipulated by EN 12828.
The heat pump manager settings and
any external regulation system which
may be connected must be adapted to
the present integration diagram.
Glen Dimplex Deutschland GmbH
Dimplex Division
Am Goldenen Feld 18
95326 Kulmbach
Page 4/5
Subject to change and errors!
E-mail: dimplex@dimplex.de
Internet: www.dimplex.de
Internet: 26.07.2007
Phone: +49 (0)9221 709-201
Fax: +49 (0)9221 709-339
Brine-to-water heat pump, Integration Diagram, Heat pump and immersion heater
Legend:
1.
1.1
1.2
1.3
1.4
1.5
1.6
2.
3.
3.1
4.
5.
6.
7.
8.
9.
10.
13.
Heat Pump
Air-to-water heat pump
Brine-to-water heat pump
Water-to-water heat pump
Reversible air-to-water heat pump
Reversible brine-to-water heat pump
Reversible water-to-water heat pump
Heat pump manager
Buffer tank
Parallel buffer tank
Hot water cylinder
Swimming pool heat exchanger
Passive cooling station with cooling controller N6
Heating and silent or dynamic cooling
Fan convector with 4-wire connection
Cooling circuit only
Heating circuit only
Heat source
Domestic hot water distribution system:
DDV 32
EB KPV
KPV 25
MMB 25
MMH 25
SST 25
VTB 25
WWM 25
Dual differential pressureless manifold (up to 2.5 m³/h)*
Extension module for compact manifold (up to 2.0 m³/h)*
Compact manifold with overflow valve (up to 1.3 m³/h)*
In combination with EB KPV (up to 2.0 m³/h)*
Mixer module, bivalent (up to 2.0 m³/h)*
Mixer module for heating circuit
Solar station for hot water
Manifold bar (up to 2.5 m³/h)*
Hot water module / unmixed heating circuit (up to 2.5 m³/h)*
* Recommended max. heating waterflow
Glen Dimplex Deutschland GmbH
Dimplex Division
Am Goldenen Feld 18
95326 Kulmbach
E9
E10
E10.1
E10.2
E10.3
E10.5
F7
K20
K21
M11
M12
M13
M14
M15
M16
M17
M18
M19
MA
MZ
N1
N2
N3/N4
N6
N12
R1
R2
R3
R4
R5
R9
R11
R13
TC
Y5
Y6
Y7
Y8
Page 5/5
Subject to change and errors!
E-mail: dimplex@dimplex.de
Internet: www.dimplex.de
Flange heater, hot water
2nd heat generator (HG2)
Immersion heater
Oil/gas boiler
Solid fuel boiler
Solar energy system
Safety temperature monitor
Contactor for 2nd heat generator
Contactor for immersion heater hot water
Primary pump for heating operation
Primary pump for cooling operation
Heat circulating pump for main circuit
Heat circulating pump for heating circuit 1
Heat circulating pump for heating circuit 2
Auxiliary circulating pump
Cooling circulating pump
Hot water circulating pump
Swimming pool water circulating pump
Mixer open
Mixer closed
Heating controller
Cooling controller for reversible heat pumps
Room climate control stations
Cooling controller for passive cooling
Solar controller
External wall sensor
Return flow sensor
Hot water sensor
Return flow sensor for cooling water
Temperature sensor for heating circuit 2
Flow sensor (antifreeze)
Flow sensor for cooling water
Sensor for heating circuit 3 / bivalent-renewable
Room temperature controller
Three-way distribution valve
Two-way valve
Three-way mixing valve
Three-way valve (closing time max. 10 sec.)
Internet: 26.07.2007