6 CONDUCTOR CABLE (SUPPLIED)
TO PREVENT RISK
FROM ELECTRIC SHOCK,
DE-ENERGIZE THIS
UNIT AND DISCONNECT
TELEPHONE LINES
BEFORE SERVICING.
WARNING
NOTES:
1. SWITCHED 12V, AUXILIARY 12V, CONSOLE, AND OUTPUTS 1-8 ARE INCLUDED IN THE TOTAL DEVICE LOAD, WHICH CANNOT EXCEED 1 AMP.
GREEN
YELLOW
SWITCHED
12 VDC
1A Max.
(See NOTE 1)
RED
EARTH
GROUND
BLACK
2. OUTPUTS LABELED "INT" AND "EXT" CANNOT EXCEED 1 AMP, SPLIT BETWEEN THE TWO OUTPUTS.
OUTPUT OUTPUT
OUTPUT OUTPUT OUTPUT OUTPUT OUTPUT OUTPUT OUTPUT
100 mA Max. (See NOTE 1)
1 Amp Max.
(See NOTE 2)
AUXILIARY 12 VDC
1A Max.
(See NOTE 1)
11A02-2
6' KEYPAD
CABLE (Supplied)
CONNECT CABLE
TO CONTROLLER,
PLUG MODULAR
END INTO
RJ31X JACK
ALL CIRCUITS EXCEPT FOR THE BATTERY
ARE POWER-LIMITED (CLASS II)
GREEN
44A07-1
TRANSFORMER
CABLE (Supplied)
BLACK / RED
CONTROL
S ECURITY
BUTTONS
ALL
TEMP
STATUS
EVENTS
MESSAGE
SETUP
KEYPAD(S)
POL
FI RE
L
A UX
ME NU
YELLOW
CANCEL
ZONE
INPUT
ZONE
INPUT
ZONE
INPUT
ZONE
INPUT
ZONE
INPUT
ZONE
INPUT
ZONE
INPUT
ZONE
INPUT
ZONES 1-16 ARE CONFIGURABLE FOR AUXILIARY OR TEMPERATURE.
ZONE
INPUT
ZONE
INPUT
ZONE
INPUT
ZONE
INPUT
ZONE
INPUT
ZONE
INPUT
ONLY ZONES 9-16 MAY BE CONFIGURED AS ENERGY SAVER ZONES.
ONLY ZONE 16 MAY BE USED FOR HAI REMOTE CONTROL THERMOSTATS.
BLACK WIRE TO RED WIRE TO +
POWER CELL PC5-12
OR EQUIVALENT
ZONE
INPUT
HAI REMOTE
CONTROL
THERMOSTAT(S)
POWER TRANSFORMER
Status
REVERE
MODEL RT-R2440SL/M
OR EQUIVALENT
<Program
UPB™
Powerline Interface Module
24 VAC
40 VA
44A07-1
TRANSFORMER
CABLE (Supplied)
BATTERY
12V 5AH
PLANNING
Before you start, the Lumina system should be planned as follows:
• Thoroughly review Appendix A “Understanding HLC” for an overview of an HLC system.
• Complete the worksheet(s) in Appendix B “HLC Planner” to plan the lighting scheme for each room.
• Give consideration to where the controller will go. Remember that it needs a duplex receptacle not controlled by a switch,
preferably on its own circuit, within 5 feet of the controller.
Page 1
INSTALLATION
1) Install HLC Switches and Controllers
Install the HLC Dimmers and Switches, 6-Button Room Controllers, and 8-Button House Controllers according to the instructions
that came with each device.
2) Install the HLC Phase Coupler
Install the supplied HLC Phase Coupler (P/N: 39A00-1) according to the instructions that came with the unit.
3) Mount the Lumina Enclosure
Mount the Lumina enclosure securely to the wall in the selected location using screws and wall anchors, as appropriate.
4) Ground the Lumina Controller
GROUND THE LUMINA CONTROLLER’S "EARTH GND" TERMINAL TO A COLD WATER PIPE OR TO A 4-FOOT
GROUND ROD TO PRESERVE ITS BUILT-IN TRANSIENT PROTECTION. USE 14 GAUGE WIRE. TRANSIENT
PROTECTION WILL NOT WORK IF THE CONTROLLER IS NOT PROPERLY GROUNDED.
COLD WATER PIPE
OR GROUND ROD
GOUNDING METHOD MUST BE IN
ACCORDANCE WITH THE NATIONAL
ELECTRIC CODE, ANSI/NFPA 70.
5) Connect the Powerline Interface Module (PIM) to the Lumina
Locate the supplied PIM (P/N: 36A00-1). Plug the PIM into a 120 VAC outlet. Plug one end of the supplied 6-conductor
modular cable into the connector marked “J3” (SERIAL 3) on the Lumina controller and plug the other end into the modular
connector on the PIM as shown.
6 CONDUCTOR
Status
<Program
UPB™
Powerline Interface Module
Page 2
6) Install the Lumina Keypad
a)
Connect the supplied keypad (P/N: 33A00-19) using the supplied 6’ Keypad Cable (P/N: 11A02-2) as follows:
11A02-2 Cable
RED
BLACK
YELLOW or WHITE
GREEN
Lumina Controller
CONSOLE 12V
CONSOLE GND
CONSOLE A
CONSOLE B
b) Remove the keypad from the back plate by gently prying the unit open with a screwdriver.
c)
Mount the back plate to the wall. Mounting holes are designed to fit on a single or double gang box, or directly to the wall.
d) Plug the cable into the connector on the keypad Printed Circuit Board (J1) as shown.
GREEN
BLACK
YELLOW OR WHITE
Snap the console face on to the back plate. Remove protective film from the LCD lens.
RED
e)
SUPPLIED 6' KEYPAD CABLE
P/N: 11A02-2
KEYPAD PC BOARD
(MOUNTED TO KEYPAD FACE)
BACK PLATE
BLACK
RED
GREEN
YELLOW OR WHITE
J1
SUPPLIED 6' KEYPAD CABLE
P/N: 11A02-2
(PLUGS INTO J1)
Page 3
7) Connect the Power Transformer
a)
Connect the supplied 24V, 40VA Power Transformer using the supplied Power Cable (P/N: 44A07-1).
b) Plug the Power Transformer into a 120 VAC outlet.
- The “AC ON” LED (D25) should illuminate.
- Within one minute, the “STATUS” LED (D24) should begin blinking at a rate of 1 blink per second.
POWER TRANSFORMER
REVERE
MODEL RT-R2440SL/M
OR EQUIVALENT
24 VAC
40 VA
44A07-1
TRANSFORMER
CABLE (Supplied)
8) Connect the Battery
Unplug the Power Transformer to shut down the controller. Connect the black battery wire to the – (negative) battery terminal of
the supplied battery. Connect the red battery wire to the + (positive) battery terminal. The controller should not start.
a)
Plug in the Power Transformer. The system should
start.
b) Unplug the Power Transformer. The system should
continue to run on the battery (the “STATUS” LED will
continue to flash).
c)
Plug the Power Transformer back in and secure it to the
outlet.
BLACK WIRE TO RED WIRE TO +
POWER CELL PC5-12
OR EQUIVALENT
Page 4
BATTERY
12V 5AH
BASIC OPERATION AND CONFIGURATION
The Lumina keypad is designed with everything that is necessary for you to operate and configure the Lumina lighting and automation
system. Once the controller is powered up, the following is displayed on the Lumina keypad:
--:--
HOME
SYSTEM OK
Display Menus
The system has been designed to be easy to operate. Whenever you press a key on the keypad, the top line of the display will indicate
what you are doing. To the right of that is your selection or current setting. The bottom line will show a menu of your next options.
To the lower right corner of the display is the direction arrow(s). Where possible, the up (↑), down (↓), and two-headed (¦) arrow
characters are shown on the keypad display to indicate which arrow keys may be pressed at that time.
Main Menu
The main menu is entered from the top-level display by pressing the ' # ' key. This menu displays all of the functions that you can
perform from the keypad. It is not necessary to display the main menu before selecting a function if the number for the desired menu
item is known.
Error Beeps
If you press a key that is invalid for the function that you are doing, the keypad will beep 3 times, indicating that it is not a valid
option. Look at the bottom line of the display to see what keys you can press next.
Trouble Beeps
The Lumina controller constantly checks the entire system for proper operation. If trouble is found, the trouble is displayed on the
bottom line and the keypad will beep at the rate of two beeps per second to alert you to the trouble.
To silence the beeper, press the ' * ' key.
Confirmation Beep
When you have successfully completed a function, such as entering a program or changing a setup item, the keypad will beep once.
Cancel
If you wish to cancel a selection or return to the top-level display, press the ' * ' key. You may have to press it more than once,
depending on how far into the function (menu) you are. Each time you cancel out of an operation, the keypad will beep once to
indicate that you have canceled.
The ' * ' key is also used if you make a mistake while entering a number. For example, if you enter a 2 when you meant to enter a 3,
press the ' * ' key to start over.
Page 5
SETUP
The Setup menu is used to configure the system and to give text descriptions to all of the HLC lighting devices. To enter the Setup
menu, from the top-level display or from the main menu, press the 9 (SETUP) key on the numeric keypad.
Upon entry to the Setup mode, you will first be prompted to enter a valid code:
SET UP
ENTER CODE:
Use the default code to enter the Setup mode (the default code is 1 1 1 1):
SET UP
1=CODES 2=TIME
3=PROG ↓
4=DIAL 5=AREA
7=NAMES 8=VOICE
6=MISC
↑
Set the Time and Date
To set up time and date, from the Setup menu, press the 2 (TIME) key. You will be prompted to enter the new time and date.
AM/PM must be specified for the time if that format is being used, otherwise the entered time should be 13:00-23:59.
TIME:
HHMM ↑=AM ↓=PM
DAYLIGHT SAVINGS TIME?
0=NO 1=YES
If Daylight Savings Time is currently being observed (between spring and fall), set this item to "Yes". If Daylight Savings Time is not
currently being observed (between fall and spring) or is not observed in your geographic location, set this item to "No". This item is
used to correctly calculate the times for sunrise and sunset. Once the time is set, the Lumina controller will automatically adjust the
"time of day" each time daylight savings time begins and ends.
Next you are prompted to enter the date. If the current date is February 8, 2006, enter it as “0 2 0 8 0 6”.
ENTER DATE:
MMDDYY
Assign a Name to HLC Lighting Devices
Before naming HLC Dimmers, Switches, and 6-Button Room Controllers, you should have thoroughly reviewed Appendix A
“Understanding HLC” and have completed the worksheet(s) in Appendix B “HLC Planner”.
You should assign a name to the following HLC devices:
¾
¾
Name the Room Controllers that resides on the 1st unit in each Room (i.e. Unit 1, 9, 17, 25, etc.)
Name all of the Lighting Loads (Dimmers and Switches) in each Room
You should not assign a name to the following HLC devices:
∅ Do not name Room Controllers that reside between the 2nd and 7th unit in a Room
∅ Do not name House Controllers that reside on the 8th unit in a Room
Page 6
You should assign a name to each HLC lighting device (as described above) before you configure it. Lumina has a list of names for
you to select from. To name the HLC devices, from the Setup menu, press the 7 (NAMES) key:
UNIT 1:
00-95
#=LIST ↓
Press the ' # ' key to display a list of names that are stored in the controller. Each name in the list is displayed on the bottom line of the
display.
UNIT 1:
Basement
↓
When using the list of names, the following should be observed:
¾
¾
¾
¾
The first item in the list is blank. This is used to delete an existing name for the respective Unit Number.
The list is in alphabetical order.
If the Unit Number is the 1st unit in a Room (i.e. Unit 1, 9, 17, 25, etc.), the list will start with Room names.
In the Unit Number is between the 2nd and 8th unit in a Room, the list will start with Lighting Load names.
Use the up arrow (↑) and down arrow (↓) keys to scroll through the list of available names for the device. When appropriate name
appears, press the ' # ' key to select that name for the device. The name now appears next to the Unit designation:
UNIT 1:
00-95
Living Room
#=LIST ↓
Once the name is selected for the specified Unit, press the down arrow key to name the next unit.
Delete a Unit Name
If you remove a device, move a device to a different location, or program a device into an incorrect location, you should delete the
existing name for the respective Unit Number.
To delete an existing name, from the Setup menu, press the 7 (NAMES) key. Use the up arrow (↑) and down arrow (↓) keys to scroll
through the list of existing names. When the Unit Number or name appears that you wish to delete, press the ' # ' key:
UNIT 7:
00-95
Table Lamp
#=LIST ↓
Press the ' # ' key to display a list of names that are stored in the controller. The first name is actually blank:
UNIT 7:
Table Lamp
↓
Simply press the ' # ' key to delete the name.
UNIT 7:
00-95
#=LIST ↓
Page 7
CONFIGURING HLC DEVICES
Before configuring HLC Dimmers and Switches, 6-Button Room Controllers, and 8-Button House Controllers, you should have
thoroughly reviewed Appendix A “Understanding HLC” and have completed the worksheet(s) in Appendix B “HLC Planner”.
When configuring HLC devices using the Lumina keypad, you can configure the device by selecting the name of the device from the
list of named units, or by entering the Unit Number of the device followed by the ' # ' key.
Note: The following steps will guide you through configuring all named devices first. Then, it will guide you through configuring
unnamed devices.
Using the worksheet(s) in Appendix B, configure each device as follows:
STEP 1
On the Lumina keypad, from the top-level display, press 6 (STATUS), and then press 1 (CTRL). The first named unit is displayed:
Living Room
STATUS: OFF
STEP 2
Configuring Room Controllers
If the named unit is a Room Controller, go to the specified HAI UPB™ 6-Button Room Controller and put it in Setup mode as
follows:
Room Controller Setup
Step
1
2
Operation
Press and hold the “ON” and “OFF” pushbuttons simultaneously for at least 3 seconds.
All of the LED indicators will blink to indicate that the HAI UPB™ 6-Button Room Controller is in Setup Mode.
Note: The HAI 6-Button Room Controller will automatically exit Setup mode after 5 minutes. To manually exit Setup
mode, press and hold the “ON” and “OFF” pushbuttons simultaneously for at least 3 seconds.
Back at the Lumina keypad, press ' # # '. The display shows:
CONFIGURE Living Room
STARTING
Page 8
The display will provide you with step-by-step configuration status. When complete, the display shows:
CONFIGURE Living Room
COMPLETED
Once completed, press the ' * ' key to return to the Status display.
STEP 3
Press the down arrow to display the next named device.
Configuring Lighting Loads
If the named unit that is displayed is a Lighting Load (i.e. Dimmer or Switch), go to the specified HAI UPB™ Wall Dimmer or Switch
and put it in Setup mode as follows:
Lighting Load Setup
Step
1
2
Operation
Tap the rocker switch quickly 5 times.
The HAI UPB™ Wall Dimmer or Switch will flash the lighting load one time and blink its LED blue to indicate that it is
in Setup Mode.
Note: The switch will automatically exit Setup mode after 5 minutes. To manually exit Setup mode, tap the switch
quickly 2 times.
Back at the Lumina keypad, press ' # # '. The display shows:
CONFIGURE -Cans
STARTING
The display will provide you with step-by-step configuration status. When complete, the display shows:
CONFIGURE -Cans
COMPLETED
Once completed, press the ' * ' key to return to the Status display.
Page 9
STEP 4
Press the down arrow to display the next named device.
Using the worksheet(s) as a guide, configure all named units as described in Step 2 and Step 3.
STEP 5
Configure Unnamed Room Controllers
Room Controllers that reside between the 2nd and 7th unit in a Room should be unnamed. To configure a Room Controller between
the 2nd and 7th unit in a Room, enter its Unit Number followed by the ' # ' key.
Put the Room Controller into Setup mode as descried under “Room Controller Setup” in Step 2.
Back at the Lumina keypad, press ' # # '. The display shows:
CONFIGURE UNIT 2
STARTING
The display will provide you with step-by-step configuration status. When complete, the display shows:
CONFIGURE UNIT 2
COMPLETED
Once completed, press the ' * ' key to return to the Status display. Repeat Step 5 for each unnamed Room Controller.
STEP 6
Configure Unnamed House Controllers
House Controllers that reside on the 8th unit in a Room should be unnamed. To configure a House Controller on the 8th unit in a
Room, enter its Unit Number followed by the ' # ' key.
Go to the specified HAI UPB™ 8-Button House Controller and put it in Setup mode as follows:
House Controller Setup
Step
1
2
Operation
Press and hold the “1” and “8” pushbuttons simultaneously for at least 3 seconds.
All of the LED indicators will blink to indicate that the HAI UPB™ 8-Button House Controller is in Setup Mode.
Note: The HAI 8-Button House Controller will automatically exit Setup mode after 5 minutes. To manually exit Setup
mode, press and hold the “1” and “8” pushbuttons simultaneously for at least 3 seconds.
Page 10
Back at the Lumina keypad, press ' # # '. The display shows:
CONFIGURE UNIT 8
STARTING
The display will provide you with step-by-step configuration status. When complete, the display shows:
CONFIGURE UNIT 8
COMPLETED
Once completed, press the ' * ' key to return to the Status display. Repeat Step 6 for each unnamed House Controller.
Configuring Lighting Scenes in a Room
Each HLC device in a room can store up to four different preset lighting scenes (Scenes A-D) and one “On” Scene (preset lighting
levels for each device when the room is turned on).
To set a lighting scene using a Room Controller:
Each lighting scene can also be set or easily changed using the pushbuttons on the HAI UPB™ 6-Button Room Controller, as follows:
1) Press the desired pushbutton on the HAI UPB™ 6-Button Room Controller to activate the current scene (preset lighting
level) in each of the HLC devices.
2) Adjust all of the HLC devices in the room to the desired lighting levels. The desired lighting levels may be set manually at
the switch by pressing the top of the paddle to brighten the light or the bottom of the paddle to dim the light.
Page 11
3) Press the pushbutton on the HAI UPB™ 6-Button Room Controller five (5) times quickly.
4) Each UPB™ Wall Switch Dimmer will flash its lighting load one time to indicate that the new level has been configured.
Whenever the scene command is transmitted, by pressing the Scene Button (A-D) on the Room Controller, each HLC device in the
specified room will brighten or fade to its preset level for the selected scene.
To set a lighting scene using the Lumina keypad:
1) Adjust all of the HLC devices in the room to the desired lighting levels. The desired lighting levels may be set manually at
the switch by pressing the top of the paddle to brighten the light or the bottom of the paddle to dim the light.
2) After the desired lighting levels are set, from the top-level display or from the main menu, press the 1 (CTRL) key on the
Lumina keypad.
3) Lumina will display the first named unit in that list. Use the down arrow key to scroll through the list. Press the ' # ' key to
select the desired room.
4) Press the 6 (SET) key followed by 1 (On Scene) or 2-5 (Scene A-D) to save the new “light levels” for each device in the
selected room.
Living Room SET
1=ON 2-5=A-D
Whenever the scene command is transmitted each HLC device in the specified room will brighten or fade to its preset level for the
selected scene.
Page 12
UNIT 9
UNIT 1
UNIT 17
ROOM 3
A1
UNIT 49
ROOM 7
OR
HLC LOAD OR
HOUSE
CONTROLLER
UNIT 64
OR
HLC LOAD OR
HOUSE
CONTROLLER
UNIT 56
OR
HLC LOAD OR
HOUSE
CONTROLLER
UNIT 48
OR
HLC LOAD OR
HOUSE
CONTROLLER
UNIT 40
OR
HLC LOAD OR
HOUSE
CONTROLLER
UNIT 32
OR
HLC LOAD OR
HOUSE
CONTROLLER
UNIT 24
HLC LOAD OR
HOUSE
CONTROLLER
UNIT 16
HLC LOAD OR
HOUSE
CONTROLLER
UNIT 8
HLC LOADS
ROOM 8
UNITS 58-63
OR
HLC LOADS
ROOM 7
UNITS 50-55
UNIT 57
ROOM 8
OR
HLC LOADS
ROOM 6
UNITS 42-47
UNIT 41
ROOM 6
HLC LOADS
ROOM 5
UNITS 34-39
UNIT 33
ROOM 5
HLC LOADS
ROOM 2
UNITS 9-15
HLC LOADS
ROOM 4
UNITS 26-31
UNIT 25
ROOM 4
HLC LOADS
ROOM 1
UNITS 2-7
HLC LOADS
ROOM 3
UNITS 18-23
ROOM 2
ROOM 1
AVAILABLE UNITS:
8, 16, 24, 32, 40, 48, 56, and 64
HOUSE CONTROLLER
(CONTROLS UP TO 8 ROOMS)
APPENDIX A – UNDERSTANDING HLC
APPENDIX A – UNDERSTANDING HLC
HLC OVERVIEW
HAI Lighting Control (HLC) combines HAI UPB™ Wall Switches, Dimmers, and Modules, HAI UPB™ Room Controllers, and HAI
UPB™ House Controllers to create lighting scenes that set the proper mood and ambiance for various activities throughout a home.
HLC format is a defined structure for configuring, programming, and operating all the HLC lighting devices in a home.
Room Controllers control up to 7 lighting loads in a room. House Controllers control up to 8 Rooms of HLC lighting.
HAI manufactured UPB™ devices (collectively referred to as HLC devices) are configured using the Lumina keypad.
About Rooms
Each “room” of HLC lighting consists of 8 consecutive unit numbers, starting at Unit 1 (i.e. Room 1 = Units 1-8, Room 2 = Units 916, Room 3 = Units 17-24, etc.). Each room can consist of a maximum of 8 HLC devices, configured as follows:
¾
¾
¾
Up to 7 HAI UPB™ Wall Switches, Dimmers, and/or Modules (for controlling up to 7 lighting loads in a room or area)
1 or more Room Controllers (set a scene in a room, turn the room on and off, and dim and brighten the room)
1 House Controller (for controlling up to 8 rooms of HLC lighting)
The first unit number in each room (i.e. 1, 9, 17, 25, etc.) is reserved for controlling the room; this is where the Room Controller will
reside. The name for this unit should reflect the room name (e.g. Living Room, Kitchen, Great Room, Theater, etc.). HLC Wall
Switches, Dimmers, or Modules cannot be programmed to these unit numbers. If one or more Room Controllers are used, the first
Room Controller should be set to the first unit number in the group (i.e. Unit 1 – Room 1); additional Room Controllers can be used
by setting each to any other unused unit number in the group between the 2nd and 7th unit number (i.e. Unit 2-7 – Room 1).
ROOM 1
UNIT 1
LIVING ROOM
ROOM CONTROLLER
ROOM 1
ROOM 1
ROOM 1
UNIT 6
UNIT 7
ROOM 8
ROOM 1
ROOM 1
ROOM 1
ROOM 1
ROOM 1
UNIT 1
UNIT 2
UNIT 3
UNIT 4
UNIT 5
1ST LIVING ROOM
ROOM CONTROLLER
LIGHTING LOADS IN
LIVING ROOM
ROOM 1
ROOM 1
ROOM 1
UNIT 6
UNIT 7
ROOM 8
ROOM 1
ROOM 1
ROOM 1
UNIT 3
UNIT 4
UNIT 5
ROOM 1
UNIT 2
2ND LIVING ROOM
ROOM CONTROLLER
LIGHTING LOADS IN
LIVING ROOM
About Room Controllers
The HAI UPB™ 6-Button Room Controller allows for lighting control of a room where HAI UPB™ Wall Switches, Dimmers, and
Modules have been installed. From a Room Controller the room can be turned off (all loads in the group are turned off), turned on (all
loads in the group are turned on), brightened (all loads are brightened from their current level), dimmed (all loads are dimmed from
their current level), or set to one of 4 lighting scenes (A-D).
Room Controller LED Indicators
When the room is turned on, the LED indicator behind the “On” button is illuminated and all others are turned off. When the room is
turned off, the LED indicator behind the “Off” button is illuminated and all others are turned off. When the room is brightened, the
LED indicator behind the “On” is illuminated and all others are turned off. When the room is dimmed, the LED indicator that is
currently illuminated stays on. When the room is set to a lighting scene (A-D), the LED indicator behind the respective scene letter is
illuminated and all others are turned off.
A2
APPENDIX A – UNDERSTANDING HLC
The Lumina controller keeps track of the exact status of each unit even when a lighting scene is initiated by the Room Controller.
Room Controllers also keep track of when individual switches in a room are turned on and off. When all of the lighting loads in a
room are turned off, the “Off” indicator is illuminated. If any of the lighting loads in a room are turned on at an HAI UPB™ Wall
Switch or Dimmer, the “On” indicator will illuminate and the “Off” indicator is turned off. Likewise, if the “On” indicator or one of
the scene indicators is illuminated, and then all of the lighting loads are turned off at HAI UPB™ Wall Switches, the “Off” indicator
will illuminate and any others are turned off.
About House Controllers
Each HAI UPB™ 8-Button House Controller allows for controlling all 8 rooms
of lighting where HAI UPB™ Wall Switches, Dimmers, and Modules have been
installed.
Each button on the House Controller is used to toggle all of the lights in the
respective room on and off. When the room is turned on, the LED indicator
behind the respective button is illuminated and all of the lights in the room are
turned on. When the room is turned off, the LED indicator behind the respective
button is turned off and all of the lights in the room are turned off. If a lighting
load in the respective room is turned on, the LED indicator behind the button is
illuminated. When all lighting loads in the respective room are turned off, the
LED indicator behind the button is turned off.
Each House Controller controls 8 consecutive rooms (i.e. Room 1-8, Room 9-16,
Room 17-24, and Room 25-31). To configure a House Controller to control a
group of 8 rooms, it must be set to the last unit number in one of the respective
rooms. For example, a House Controller set to Unit 8, 16, 24, 32, 40, 48, 56, or
64 can be used to control Rooms 1-8. This allows you to have up to 8 House
Controllers throughout the house that control Rooms 1-8.
UNIT 8
ROOM 1
UNIT 1
LIVING ROOM
ROOM CONTROLLER
ROOM 1
ROOM 1
ROOM 1
UNIT 5
UNIT 6
ROOM 7
ROOM 1
ROOM 1
ROOM 1
UNIT 2
UNIT 3
UNIT 4
LIGHTING LOADS IN
LIVING ROOM
HOUSE CONTROLLER
(CONTROLS UP TO 8 ROOMS)
AVAILABLE UNITS:
8, 16, 24, 32, 40, 48, 56, and 64
ROOM 1
ROOM 2
ROOM 3
ROOM 4
ROOM 5
ROOM 6
ROOM 7
ROOM 8
UNIT 1
UNIT 9
UNIT 17
UNIT 25
UNIT 33
UNIT 41
UNIT 49
UNIT 57
When used with Lumina Pro, House Controllers for Rooms 9-16, 17-24, and 25-31 are configured in a similar manner. For example:
•
•
•
Unit 72, 80, 88, 96, 104, 112, 120, and 128 can be used to control Rooms 9-16.
Unit 136, 144, 152, 160, 168, 176, 784, and 192 can be used to control Rooms 17-24.
Unit 200, 208, 216, 224, 232, 240, and 248 can be used to control Rooms 25-31.
A3
APPENDIX B – HLC PLANNER
It is very important to plan each Room by filling in the worksheets for each Room.
When filling in the worksheet, put a check in the box under “HLC Device Type” for each unit in the room, then:
You should assign a name to the following HLC devices:
¾
¾
Room Controllers that resides on the 1st unit in each Room (i.e. Unit 1, 9, 17, 25, etc.)
Lighting Loads (Dimmers and Switches) in each Room
You should not assign a name to the following HLC devices:
∅ Room Controllers that reside between the 2nd and 7th unit in a Room
∅ House Controllers that reside on the 8th unit in a Room
Lumina can have up to 8 Rooms and Lumina Pro can have up to 31 Rooms.
In this example, Room 1 is the Living Room. The Living Room consists of 2 Room Controllers (one at each entry into the Living
Room), 5 Lighting Loads, and 1 House Controller (which controls up to 8 Rooms).
ROOM 1: Living Room
Unit
1st
2nd
3rd
4th
5th
6th
7th
8th
Unit Number
Unit
Unit
Unit
Unit
Unit
Unit
Unit
Unit
1
2
3
4
5
6
7
8
HLC Device Type
;
…
;
;
;
;
;
…
Room Controller
Lighting Load
Lighting Load
Lighting Load
Lighting Load
Lighting Load
Lighting Load
Lighting Load
;
…
…
…
…
…
;
Room Controller
Room Controller
Room Controller
Room Controller
Room Controller
Room Controller
House Controller
Name
Living Room
-Cans
-Chandelier
-Sconce
-Spot Lights
-Table Lamp
Room 2 is the Kitchen. The Kitchen consists of 1 Room Controller and 7 Lighting Loads.
ROOM 2: Kitchen
Unit
1st
2nd
3rd
4th
5th
6th
7th
8th
Unit Number
Unit
Unit
Unit
Unit
Unit
Unit
Unit
Unit
1
2
3
4
5
6
7
8
HLC Device Type
;
;
;
;
;
;
;
;
Room Controller
Lighting Load
Lighting Load
Lighting Load
Lighting Load
Lighting Load
Lighting Load
Lighting Load
…
…
…
…
…
…
…
Room Controller
Room Controller
Room Controller
Room Controller
Room Controller
Room Controller
House Controller
B1
Name
Kitchen
-Breakfast
-Cans
-Cabinets
-Sink
-Island
-Ovrhd Lghts (Overhead Lights)
-Perm Lights (Perimeter Lights)
APPENDIX B – HLC PLANNER WORKSHEET
ROOM 1:
Unit
1st
2nd
3rd
4th
5th
6th
7th
8th
Unit Number
Unit
Unit
Unit
Unit
Unit
Unit
Unit
Unit
1
2
3
4
5
6
7
8
HLC Device Type
…
…
…
…
…
…
…
…
Room Controller
Lighting Load
Lighting Load
Lighting Load
Lighting Load
Lighting Load
Lighting Load
Lighting Load
…
…
…
…
…
…
…
Name
Room Controller
Room Controller
Room Controller
Room Controller
Room Controller
Room Controller
House Controller
ROOM 2:
Unit
Unit Number
1st
2nd
3rd
4th
5th
6th
7th
8th
Unit 9
Unit 10
Unit 11
Unit 12
Unit 13
Unit 14
Unit 15
Unit 16
HLC Device Type
…
…
…
…
…
…
…
…
Room Controller
Lighting Load
Lighting Load
Lighting Load
Lighting Load
Lighting Load
Lighting Load
Lighting Load
…
…
…
…
…
…
…
Name
Room Controller
Room Controller
Room Controller
Room Controller
Room Controller
Room Controller
House Controller
ROOM 3:
Unit
1st
2nd
3rd
4th
5th
6th
7th
8th
Unit Number
Unit
Unit
Unit
Unit
Unit
Unit
Unit
Unit
17
18
19
20
21
22
23
24
HLC Device Type
…
…
…
…
…
…
…
…
Room Controller
Lighting Load
Lighting Load
Lighting Load
Lighting Load
Lighting Load
Lighting Load
Lighting Load
…
…
…
…
…
…
…
…
Room Controller
Lighting Load
Lighting Load
Lighting Load
Lighting Load
Lighting Load
Lighting Load
Lighting Load
…
…
…
…
…
…
…
Name
Room Controller
Room Controller
Room Controller
Room Controller
Room Controller
Room Controller
House Controller
ROOM 4:
Unit
1st
2nd
3rd
4th
5th
6th
7th
8th
Unit Number
Unit
Unit
Unit
Unit
Unit
Unit
Unit
Unit
25
26
27
28
29
30
31
32
HLC Device Type
…
…
…
…
…
…
…
Room Controller
Room Controller
Room Controller
Room Controller
Room Controller
Room Controller
House Controller
B2
Name
APPENDIX B – HLC PLANNER WORKSHEET
ROOM 5:
Unit
1st
2nd
3rd
4th
5th
6th
7th
8th
Unit Number
Unit
Unit
Unit
Unit
Unit
Unit
Unit
Unit
33
34
35
36
37
38
39
40
HLC Device Type
…
…
…
…
…
…
…
…
Room Controller
Lighting Load
Lighting Load
Lighting Load
Lighting Load
Lighting Load
Lighting Load
Lighting Load
…
…
…
…
…
…
…
Name
Room Controller
Room Controller
Room Controller
Room Controller
Room Controller
Room Controller
House Controller
ROOM 6:
Unit
1st
2nd
3rd
4th
5th
6th
7th
8th
Unit Number
Unit
Unit
Unit
Unit
Unit
Unit
Unit
Unit
41
42
43
44
45
46
47
48
HLC Device Type
…
…
…
…
…
…
…
…
Room Controller
Lighting Load
Lighting Load
Lighting Load
Lighting Load
Lighting Load
Lighting Load
Lighting Load
…
…
…
…
…
…
…
Name
Room Controller
Room Controller
Room Controller
Room Controller
Room Controller
Room Controller
House Controller
ROOM 7:
Unit
1st
2nd
3rd
4th
5th
6th
7th
8th
Unit Number
Unit
Unit
Unit
Unit
Unit
Unit
Unit
Unit
49
50
51
52
53
54
55
56
HLC Device Type
…
…
…
…
…
…
…
…
Room Controller
Lighting Load
Lighting Load
Lighting Load
Lighting Load
Lighting Load
Lighting Load
Lighting Load
…
…
…
…
…
…
…
…
Room Controller
Lighting Load
Lighting Load
Lighting Load
Lighting Load
Lighting Load
Lighting Load
Lighting Load
…
…
…
…
…
…
…
Name
Room Controller
Room Controller
Room Controller
Room Controller
Room Controller
Room Controller
House Controller
ROOM 8:
Unit
1st
2nd
3rd
4th
5th
6th
7th
8th
Unit Number
Unit
Unit
Unit
Unit
Unit
Unit
Unit
Unit
57
58
59
60
61
62
63
64
HLC Device Type
…
…
…
…
…
…
…
Room Controller
Room Controller
Room Controller
Room Controller
Room Controller
Room Controller
House Controller
B3
Name
APPENDIX B – HLC PLANNER WORKSHEET
ROOM 9:
Unit
1st
2nd
3rd
4th
5th
6th
7th
8th
Unit Number
Unit
Unit
Unit
Unit
Unit
Unit
Unit
Unit
65
66
67
68
69
70
71
72
HLC Device Type
…
…
…
…
…
…
…
…
Room Controller
Lighting Load
Lighting Load
Lighting Load
Lighting Load
Lighting Load
Lighting Load
Lighting Load
…
…
…
…
…
…
…
Name
Room Controller
Room Controller
Room Controller
Room Controller
Room Controller
Room Controller
House Controller
ROOM 10:
Unit
1st
2nd
3rd
4th
5th
6th
7th
8th
Unit Number
Unit
Unit
Unit
Unit
Unit
Unit
Unit
Unit
73
74
75
76
77
78
79
80
HLC Device Type
…
…
…
…
…
…
…
…
Room Controller
Lighting Load
Lighting Load
Lighting Load
Lighting Load
Lighting Load
Lighting Load
Lighting Load
…
…
…
…
…
…
…
Name
Room Controller
Room Controller
Room Controller
Room Controller
Room Controller
Room Controller
House Controller
ROOM 11:
Unit
1st
2nd
3rd
4th
5th
6th
7th
8th
Unit Number
Unit
Unit
Unit
Unit
Unit
Unit
Unit
Unit
81
82
83
84
85
86
87
88
HLC Device Type
…
…
…
…
…
…
…
…
Room Controller
Lighting Load
Lighting Load
Lighting Load
Lighting Load
Lighting Load
Lighting Load
Lighting Load
…
…
…
…
…
…
…
…
Room Controller
Lighting Load
Lighting Load
Lighting Load
Lighting Load
Lighting Load
Lighting Load
Lighting Load
…
…
…
…
…
…
…
Name
Room Controller
Room Controller
Room Controller
Room Controller
Room Controller
Room Controller
House Controller
ROOM 12:
Unit
1st
2nd
3rd
4th
5th
6th
7th
8th
Unit Number
Unit
Unit
Unit
Unit
Unit
Unit
Unit
Unit
89
90
91
92
93
94
95
96
HLC Device Type
…
…
…
…
…
…
…
Room Controller
Room Controller
Room Controller
Room Controller
Room Controller
Room Controller
House Controller
B4
Name
APPENDIX B – HLC PLANNER WORKSHEET
ROOM 13:
Unit
Unit Number
1st
2nd
3rd
4th
5th
6th
7th
8th
Unit 97
Unit 98
Unit 99
Unit 100
Unit 101
Unit 102
Unit 103
Unit 104
HLC Device Type
…
…
…
…
…
…
…
…
Room Controller
Lighting Load
Lighting Load
Lighting Load
Lighting Load
Lighting Load
Lighting Load
Lighting Load
…
…
…
…
…
…
…
Name
Room Controller
Room Controller
Room Controller
Room Controller
Room Controller
Room Controller
House Controller
ROOM 14:
Unit
1st
2nd
3rd
4th
5th
6th
7th
8th
Unit Number
Unit
Unit
Unit
Unit
Unit
Unit
Unit
Unit
105
106
107
108
109
110
111
112
HLC Device Type
…
…
…
…
…
…
…
…
Room Controller
Lighting Load
Lighting Load
Lighting Load
Lighting Load
Lighting Load
Lighting Load
Lighting Load
…
…
…
…
…
…
…
Name
Room Controller
Room Controller
Room Controller
Room Controller
Room Controller
Room Controller
House Controller
ROOM 15:
Unit
1st
2nd
3rd
4th
5th
6th
7th
8th
Unit Number
Unit
Unit
Unit
Unit
Unit
Unit
Unit
Unit
113
114
115
116
117
118
119
120
HLC Device Type
…
…
…
…
…
…
…
…
Room Controller
Lighting Load
Lighting Load
Lighting Load
Lighting Load
Lighting Load
Lighting Load
Lighting Load
…
…
…
…
…
…
…
…
Room Controller
Lighting Load
Lighting Load
Lighting Load
Lighting Load
Lighting Load
Lighting Load
Lighting Load
…
…
…
…
…
…
…
Name
Room Controller
Room Controller
Room Controller
Room Controller
Room Controller
Room Controller
House Controller
ROOM 16:
Unit
1st
2nd
3rd
4th
5th
6th
7th
8th
Unit Number
Unit
Unit
Unit
Unit
Unit
Unit
Unit
Unit
121
122
123
124
125
126
127
128
HLC Device Type
…
…
…
…
…
…
…
Room Controller
Room Controller
Room Controller
Room Controller
Room Controller
Room Controller
House Controller
B5
Name
APPENDIX B – HLC PLANNER WORKSHEET
ROOM 17:
Unit
1st
2nd
3rd
4th
5th
6th
7th
8th
Unit Number
Unit
Unit
Unit
Unit
Unit
Unit
Unit
Unit
129
130
131
132
133
134
135
136
HLC Device Type
…
…
…
…
…
…
…
…
Room Controller
Lighting Load
Lighting Load
Lighting Load
Lighting Load
Lighting Load
Lighting Load
Lighting Load
…
…
…
…
…
…
…
Name
Room Controller
Room Controller
Room Controller
Room Controller
Room Controller
Room Controller
House Controller
ROOM 18:
Unit
1st
2nd
3rd
4th
5th
6th
7th
8th
Unit Number
Unit
Unit
Unit
Unit
Unit
Unit
Unit
Unit
137
138
139
140
141
142
143
144
HLC Device Type
…
…
…
…
…
…
…
…
Room Controller
Lighting Load
Lighting Load
Lighting Load
Lighting Load
Lighting Load
Lighting Load
Lighting Load
…
…
…
…
…
…
…
Name
Room Controller
Room Controller
Room Controller
Room Controller
Room Controller
Room Controller
House Controller
ROOM 19:
Unit
1st
2nd
3rd
4th
5th
6th
7th
8th
Unit Number
Unit
Unit
Unit
Unit
Unit
Unit
Unit
Unit
145
146
147
148
149
150
151
152
HLC Device Type
…
…
…
…
…
…
…
…
Room Controller
Lighting Load
Lighting Load
Lighting Load
Lighting Load
Lighting Load
Lighting Load
Lighting Load
…
…
…
…
…
…
…
…
Room Controller
Lighting Load
Lighting Load
Lighting Load
Lighting Load
Lighting Load
Lighting Load
Lighting Load
…
…
…
…
…
…
…
Name
Room Controller
Room Controller
Room Controller
Room Controller
Room Controller
Room Controller
House Controller
ROOM 20:
Unit
1st
2nd
3rd
4th
5th
6th
7th
8th
Unit Number
Unit
Unit
Unit
Unit
Unit
Unit
Unit
Unit
153
154
155
156
157
158
159
160
HLC Device Type
…
…
…
…
…
…
…
Room Controller
Room Controller
Room Controller
Room Controller
Room Controller
Room Controller
House Controller
B6
Name
APPENDIX B – HLC PLANNER WORKSHEET
ROOM 21:
Unit
1st
2nd
3rd
4th
5th
6th
7th
8th
Unit Number
Unit
Unit
Unit
Unit
Unit
Unit
Unit
Unit
161
162
163
164
165
166
167
168
HLC Device Type
…
…
…
…
…
…
…
…
Room Controller
Lighting Load
Lighting Load
Lighting Load
Lighting Load
Lighting Load
Lighting Load
Lighting Load
…
…
…
…
…
…
…
Name
Room Controller
Room Controller
Room Controller
Room Controller
Room Controller
Room Controller
House Controller
ROOM 22:
Unit
1st
2nd
3rd
4th
5th
6th
7th
8th
Unit Number
Unit
Unit
Unit
Unit
Unit
Unit
Unit
Unit
169
170
171
172
173
174
175
176
HLC Device Type
…
…
…
…
…
…
…
…
Room Controller
Lighting Load
Lighting Load
Lighting Load
Lighting Load
Lighting Load
Lighting Load
Lighting Load
…
…
…
…
…
…
…
Name
Room Controller
Room Controller
Room Controller
Room Controller
Room Controller
Room Controller
House Controller
ROOM 23:
Unit
1st
2nd
3rd
4th
5th
6th
7th
8th
Unit Number
Unit
Unit
Unit
Unit
Unit
Unit
Unit
Unit
177
178
179
180
181
182
183
184
HLC Device Type
…
…
…
…
…
…
…
…
Room Controller
Lighting Load
Lighting Load
Lighting Load
Lighting Load
Lighting Load
Lighting Load
Lighting Load
…
…
…
…
…
…
…
…
Room Controller
Lighting Load
Lighting Load
Lighting Load
Lighting Load
Lighting Load
Lighting Load
Lighting Load
…
…
…
…
…
…
…
Name
Room Controller
Room Controller
Room Controller
Room Controller
Room Controller
Room Controller
House Controller
ROOM 24:
Unit
1st
2nd
3rd
4th
5th
6th
7th
8th
Unit Number
Unit
Unit
Unit
Unit
Unit
Unit
Unit
Unit
185
186
187
188
189
190
191
192
HLC Device Type
…
…
…
…
…
…
…
Room Controller
Room Controller
Room Controller
Room Controller
Room Controller
Room Controller
House Controller
B7
Name
APPENDIX B – HLC PLANNER WORKSHEET
ROOM 25:
Unit
1st
2nd
3rd
4th
5th
6th
7th
8th
Unit Number
Unit
Unit
Unit
Unit
Unit
Unit
Unit
Unit
193
194
195
196
197
198
199
200
HLC Device Type
…
…
…
…
…
…
…
…
Room Controller
Lighting Load
Lighting Load
Lighting Load
Lighting Load
Lighting Load
Lighting Load
Lighting Load
…
…
…
…
…
…
…
Name
Room Controller
Room Controller
Room Controller
Room Controller
Room Controller
Room Controller
House Controller
ROOM 26:
Unit
1st
2nd
3rd
4th
5th
6th
7th
8th
Unit Number
Unit
Unit
Unit
Unit
Unit
Unit
Unit
Unit
201
202
203
204
205
206
207
208
HLC Device Type
…
…
…
…
…
…
…
…
Room Controller
Lighting Load
Lighting Load
Lighting Load
Lighting Load
Lighting Load
Lighting Load
Lighting Load
…
…
…
…
…
…
…
Name
Room Controller
Room Controller
Room Controller
Room Controller
Room Controller
Room Controller
House Controller
ROOM 27:
Unit
1st
2nd
3rd
4th
5th
6th
7th
8th
Unit Number
Unit
Unit
Unit
Unit
Unit
Unit
Unit
Unit
209
210
211
212
213
214
215
216
HLC Device Type
…
…
…
…
…
…
…
…
Room Controller
Lighting Load
Lighting Load
Lighting Load
Lighting Load
Lighting Load
Lighting Load
Lighting Load
…
…
…
…
…
…
…
…
Room Controller
Lighting Load
Lighting Load
Lighting Load
Lighting Load
Lighting Load
Lighting Load
Lighting Load
…
…
…
…
…
…
…
Name
Room Controller
Room Controller
Room Controller
Room Controller
Room Controller
Room Controller
House Controller
ROOM 28:
Unit
1st
2nd
3rd
4th
5th
6th
7th
8th
Unit Number
Unit
Unit
Unit
Unit
Unit
Unit
Unit
Unit
217
218
219
220
221
222
223
224
HLC Device Type
…
…
…
…
…
…
…
Room Controller
Room Controller
Room Controller
Room Controller
Room Controller
Room Controller
House Controller
B8
Name
APPENDIX B – HLC PLANNER WORKSHEET
ROOM 29:
Unit
1st
2nd
3rd
4th
5th
6th
7th
8th
Unit Number
Unit
Unit
Unit
Unit
Unit
Unit
Unit
Unit
225
226
227
228
229
230
231
232
HLC Device Type
…
…
…
…
…
…
…
…
Room Controller
Lighting Load
Lighting Load
Lighting Load
Lighting Load
Lighting Load
Lighting Load
Lighting Load
…
…
…
…
…
…
…
Name
Room Controller
Room Controller
Room Controller
Room Controller
Room Controller
Room Controller
House Controller
ROOM 30:
Unit
1st
2nd
3rd
4th
5th
6th
7th
8th
Unit Number
Unit
Unit
Unit
Unit
Unit
Unit
Unit
Unit
233
234
235
236
237
238
239
240
HLC Device Type
…
…
…
…
…
…
…
…
Room Controller
Lighting Load
Lighting Load
Lighting Load
Lighting Load
Lighting Load
Lighting Load
Lighting Load
…
…
…
…
…
…
…
Name
Room Controller
Room Controller
Room Controller
Room Controller
Room Controller
Room Controller
House Controller
ROOM 31:
Unit
1st
2nd
3rd
4th
5th
6th
7th
8th
Unit Number
Unit
Unit
Unit
Unit
Unit
Unit
Unit
Unit
241
242
243
244
245
246
247
248
HLC Device Type
…
…
…
…
…
…
…
…
Room Controller
Lighting Load
Lighting Load
Lighting Load
Lighting Load
Lighting Load
Lighting Load
Lighting Load
…
…
…
…
…
…
…
Room Controller
Room Controller
Room Controller
Room Controller
Room Controller
Room Controller
House Controller
B9
Name