Digi 24XStream Product manual

Add to my manuals
67 Pages

advertisement

Digi 24XStream Product manual | Manualzz

XStream™ OEM RF Module

Product Manual

v5.x00

For XStream OEM RF Module Part Numbers: X09-001…

X09-009…

X09-019…

X24-009…

X24-019…

Reliable 900 MHz and 2.4 GHz OEM RF Modules by Digi International Inc.

XH9-001…

XH9-009…

XH9-019…

XStream™ OEM RF Module – Product Manual v5.x00

XStream OEM RF Module – Product Manual v5.x00

(Part number 90002209 B)

Revision

B

Date

10/15/14

Description

Minor changes and new part number

© 2014 Digi International Inc. All rights reserved

Digi, Digi International, the Digi logo, and XStream

® are trademarks or registered trademarks of Digi International Inc. in the United States and other countries worldwide. All other trademarks mentioned in this document are the property of their respective owners.

Information in this document is subject to change without notice and does not represent a commitment on the part of

Digi International. Digi provides this document “as is,” without warranty of any kind, expressed or implied, including, but not limited to, the implied warranties of fitness or merchantability for a particular purpose. Digi may make improvements and/or changes in this manual or in the product(s) and/or the program(s) described in this manual at any time.

© 2014 Digi International Inc. ii

XStream™ OEM RF Module – Product Manual v5.x00

Contents

1.

XStream OEM RF Module

1.1.

Features

1.1.1.

Worldwide Acceptance

1.2.

Specifications

1.3.

Mechanical Drawings

1.4.

Pin Signals

1.5.

Electrical Characteristics

1.5.1.

Timing Specifications

2.

RF Module Operation

2.1.

Serial Communications

2.1.1.

UART-Interfaced Data Flow

2.1.2.

Flow Control

2.2.

Modes of Operation

2.2.1.

Idle Mode

2.2.2.

Transmit Mode

2.2.3.

Receive Mode

2.2.4.

Sleep Mode

2.2.5.

Command Mode

3.

RF Module Configuration

3.1.

Hands-on Programming Examples

3.1.1.

AT Command Example

3.1.3.

Binary Command Example

3.2.

Command Reference Table

3.3.

XStream Command Descriptions

4.

RF Communication Modes

4.1.

Addressing

4.1.1.

Address Recognition

4.2.

Basic Communications

4.2.1.

Streaming Mode (Default)

4.2.2.

Repeater Mode

4.3.

Acknowledged Communications

4.3.1.

Acknowledged Mode

4.3.2.

Multi-Streaming Mode

Appendix A: Agency Certifications

FCC Certification

OEM Labeling Requirements

Antenna Usage

FCC-Approved Antennas

© 2014 Digi International Inc.

12

12

14

14

17

10

10

11

12

19

19

19

20

21

22

37

4

8

8

6

6

10

4

5

5

40

44

44

46

38

38

39

39

50

50

51

51

52

IC (Industry Canada) Certification

Appendix B: Development Guide

XStream OEM Development Kit Contents

Interfacing Hardware

Adapters

Antennas

Interfacing Protocols

RS-232 Operation

RS-485 (2-wire) Operation

RS-485 (4-wire) and RS-422 Operation

XCTU Software

Using the XCTU Software

Appendix C: Additional Information

1-Year Warranty

Ordering Information

Contact Digi

iii

53

54

60

60

62

63

65

54

54

58

59

65

66

66

66

67

XStream™ OEM RF Module – Product Manual v5.x00

1. XStream OEM RF Module

The XStream OEM RF Module is a drop-in wireless data solution that transfers a standard asynchronous serial data stream over-the-air between devices. The module was engineered to provide OEMs and integrators with an easy-to-use wireless solution that yields reliable, long range and low cost wireless links.

1.1. Features

Long Range

9XStream (900 MHz) Range:

Indoor/Urban: up to 1500’ (450 m)

Outdoor line-of-sight: up to 7 miles (11 km) w/ 2.1 dBm dipole antenna

Outdoor line-of-sight: up to 20 miles (32 km) w/ high gain antenna

24XStream (2.4 GHz) Range:

Indoor/Urban: up to 600’ (180 m)

Outdoor line-of-sight: up to 3 miles (5 km) w/ 2.1 dBm dipole antenna

Outdoor line-of-sight: up to 10 miles (16 km) w/ high gain antenna

Receiver Sensitivity: -110 dBm (900 MHz),

-105 dBm (2.4 GHz)

Advanced Networking and Security

True peer-to-peer (no “master” required), point- to-point, point-to-multipoint, multidrop

Retries and Acknowledgements

7 hopping channels, each with over 65,000 available network addresses

Easy-to-Use

No configuration required

Advanced configurations supported through standard AT and binary

Commands

5 VDC (± 0.25 V) power supply

Continuous RF data stream up to 19.2 kbps

Portable (small form factor easily designed into a wide range of data radio systems)

Software-selectable serial interfacing rates

MODBUS, CTS, RTS, DTR, DCD (and more) I/O Support

Support for multiple data formats (parity, start and stop bits, etc.)

XII™ Interference Immunity

Power-saving Sleep Modes

FHSS (Frequency Hopping Spread Spectrum)

Fast network synchronization (~ 35 ms)

Streaming, Repeater, Multi-Streaming and

Acknowledged Modes supported

© 2014 Digi International Inc.

4

XStream™ OEM RF Module – Product Manual v5.x00

1.1.1. Worldwide Acceptance

FCC Certified (USA) – Refer to Appendix A for FCC Requirements.

Systems that include XStream Modules automatically inherit Digi Certifications

ISM (Industrial, Scientific and Medical) frequency band

Manufactured under ISO 9001:2000 registered standards

9XStream (900 MHz) OEM RF Modules are approved for use in US, Canada, Australia,

Israel.

1.2. Specifications

Table 101. XStream OEM RF Module Specifications

Specification 9XStream (900 MHz) OEM RF Module 24XStream (2.4 GHz) OEM RF Module

Performance

Indoor/Urban Range

Outdoor line-of-sight Range

Interface Data Rate

Throughput Data Rate

RF Data Rate

Transmit Power Output

Receiver Sensitivity up to 1500’ (450 m)

Up to 7 miles (11 km) w/ dipole antenna

Up to 20 miles (32 km) w/ high-gain antenna

1200 – 57,600 bps

(non-standard baud rates also supported)

9,600 bps

10,000 bps

100 mW (20 dBm)

-110 dBm

19,200 bps

20,000 bps

100 mW (20 dBm)

-107 dBm up to 600’ (180 m)

Up to 3 miles (5 km) w/ dipole antenna

Up to 10 miles (16 km) w/ high-gain antenna

1200 – 57,600 bps

(non-standard baud rates also supported)

9,600 bps

10,000 bps

50 mW (17 dBm)

-105 dBm

19,200 bps

20,000 bps

50 mW (17 dBm)

-102 dBm

Power Requirements

Supply Voltage

Receive Current

Transmit Current

Power Down Current

General

Frequency Range

Spread Spectrum

Network Topology

Channel Capacity

Serial Data Interface

Physical Properties

Module Board Size

Weight

Connector

Operating Temperature

Antenna

Integrated Wire (optional)

Connector (optional)

Impedance

5 VDC (± 0.25 V) regulated

50 mA

140 mA

< 26 µA

5 VDC (± 0.25 V) regulated

80 mA

150 mA

< 26 µA

902-928 MHz 2.4000-2.4835 GHz

Frequency Hopping, Wide band FM modulator

Peer-to-Peer, Point-to-Multipoint, Point-to-Point, Multidrop

7 hop sequences share 25 frequencies

CMOS UART

1.600” x 2.825” x 0.350” (4.06 cm x 7.18 cm x 0.89 cm)

0.8 oz (24 g)

11-pin and 4-pin, 0.1” spaced male Berg-type headers

0 to 70º C (commercial), -40 to 85º C (industrial)

¼ wave monopole, 3” (7.62 cm) length, 1.9 dBi Gain

Reverse-polarity SMA or MMCX

50 ohms unbalanced

Certifications (visit www.digi.com

for complete list)

FCC Part 15.247 OUR9XSTREAM

Industry Canada (IC) 4214A-9XSTREAM

OUR-24XSTREAM

4214A 12008

© 2014 Digi International Inc.

5

XStream™ OEM RF Module – Product Manual v5.x00

1.3. Mechanical Drawings

Figure 101. XStream Module Mechanical Drawings (shown with RPSMA antenna connector option)

1.4. Pin Signals

Figure 102. XStream OEM RF Module Pin Numbers (bottom view, pins protruding)

© 2014 Digi International Inc.

6

XStream™ OEM RF Module – Product Manual v5.x00

Table 102. J1 Pin Signal Descriptions

(Low‐asserted signals distinguished with a horizontal line over signal name.)

Module Pin Signal Name

1

DO2 / /

RS-485 Enable

2

3

4

5

6

7

8

9

10

11

DI3 / SLEEP

DO (data out)

DI (data in)

DI2 / / CMD

DO3 / RX LED

/ PWR

VCC

GND

I/O When Active Function

O* low

(clear-to-send) flow control – When pin is driven low,

UART host is permitted to send serial data to the module.

Refer to the Serial Communications (p9) and CS Command

(p23) sections for more information.

RS-485 Enable – To configure this pin to enable RS-485

(2-wire or 4--wire) communications, refer to the Serial

Communications (p9) and CS Command (p23) sections.

I*

O*

I

I**

I*

O high n/a n/a low low high

By default, DI3 pin is not used. To configure this pin to support

Sleep Modes, refer to the Sleep Mode (p13), SM Command

(p32) and PW Command (p29) sections.

Serial data exiting the module (to the UART host). Refer to the

Serial Communications (p9) section for more information.

Serial data entering the module (from UART host). Refer to the

Serial Communications (p9) section for more information.

(request-to-send) flow control – By default, this pin is not used. To configure this pin to regulate the flow of serial data exiting the module, refer to the Serial Communications (p9) and

RT Command (p31) sections.

CMD –Refer to Binary Commands (p17) and RT Command

(p31) sections to enable binary command programming.

Re-boot module.

Pin is driven high during RF data reception; otherwise, the pin is driven low. Refer to the CD Command (p22) to enable.

O low high

- Pin pulses low during RF transmission.

PWR – Indicates power is on and module is not in Sleep Mode.

I***

I

- low

-

-

Pin can be used as a backup method for entering Command

Mode during power-up. Primary method is with “+++”. Refer to the Command Mode (p16) section for more information.

5 VDC regulated (± 0.25)

Ground

* Module has 10K Ω internal pull‐up resistor

** Module has 10K Ω internal pull‐down resistor

*** Module has 100K Ω internal pull‐up resistor

Note: When integrating the XStream Module with a Host PC Board, all lines that are not used should be left disconnected (floating).

Table 1‐03. J2 Pin Signal Descriptions

Module Pin Signal Name

3

4

1

2 reserved

GND

GND

GND

J2 Pins are used primarily for mechanical stability and may be left disconnected.

© 2014 Digi International Inc.

7

XStream™ OEM RF Module – Product Manual v5.x00

1.5. Electrical Characteristics

Figure 103. System Block Diagram

Basic wireless link between hosts

The data flow sequence is initiated when the first byte of data is received in the DI Buffer of the transmitting module (XStream Module A). As long as XStream Module A is not already receiving

RF data, data in the DI Buffer is packetized, then transmitted over-the-air to XStream Module B-0

1.5.1. Timing Specifications

Figure 104. Timing Specifications (“A” and “B” refer to Figure 103.)

Table 104. AC Characteristics (SY parameter = 0, symbols correspond to Figure 103 and Figure 104.)

Symbol

T

T

T

T

TX

TL

RL

ST

Description

Latency from the time data is transmitted until received

Time that /PWR pin is driven low

Time that RX LED pin is driven high

Channel Initialization Time

19200 baud rate

(32 byte packet)

54.0 ms

8.4 ms

13.6 ms

35.0 ms

19200 timing

(B=number of bytes)

For 0 < B < 64,

T = 41.6 + (0.4 * B) ms

For B > 63,

T = 66.8 ms

For 0 < B < 14,

T = 3.24 + (0.4 * B) ms

For B > 13,

T = 8.48 ms

For 0 < B < 65,

T = 0.79 + (0.408 * B)

For B > 64,

T = 26.9 ms

35.0 ms

9600 baud rate

(32 byte packet)

72.0 ms

16.8 ms

25.6 ms

35.0 ms

9600 timing

(B=number of bytes)

For 0 < B < 40,

T = 46.27 + (0.73 * B) ms

For B >= 39 bytes,

T = 74.80 ms

For 0 < B < 14,

T = 6.50 + (0.8 * B) ms

For B > 13,

T = 16.80 ms

For 0 < B < 37,

T = 1.63 + (0.794 * B)

For B > 36,

T = 30.2 ms

35.0 ms

© 2014 Digi International Inc.

8

XStream™ OEM RF Module – Product Manual v5.x00

Table 105. DC Characteristics (Vcc = 4.75 – 5.25 VDC )

Parameter Condition Symbol

VIL

VIH

VIH2

VOL

VOH

IIL

IIH

IIL2

IIL3

IIH2

Input Low Voltage

Input High Voltage

Input High Voltage

Output Low Voltage

Output High Voltage

Input Leakage

Current I/O Pin

Input Leakage

Current I/O Pin

All input signals

All except pin pin *

IOL = 20 mA,

Vcc = 5V

IOH = -20 mA,

Vcc = 5V

Vcc = 5.5V, pin low

(absolute value)

Vcc = 5.5V, pin high

(absolute value)

, , DO

CONFIG

Min

-0.5

0.6 * Vcc

0.9 * Vcc

4.0

2.0

* Reset pulse must last at least 250 nanoseconds

** VI = the input voltage on the pin

Typical

(Vcc – VI) / 10 **

(Vcc – VI) / 47 **

(Vcc – VI) / 10 **

Max

0.3 * Vcc

Vcc + 0.5

Vcc + 0.5

0.7

0.5

3

3

µA

µA mA mA mA

Units

V

V

V

V

V

© 2014 Digi International Inc.

9

XStream™ OEM RF Module – Product Manual v5.x00

2. RF Module Operation

2.1. Serial Communications

The XStream OEM RF Module interfaces to a host device through a CMOS-level asynchronous serial port. Through its serial port, the module can communicate with any UART voltage compatible device or through a level translator to any RS-232/485/422 device.

2.1.1. UART-Interfaced Data Flow

Devices that have a UART interface can connect directly through the pins of the XStream Module as is shown in the figure below.

Figure 201. System Data Flow Diagram in a UARTinterfaced environment

(Low‐asserted signals distinguished with horizontal line over signal name.)

Serial Data

Data enters the XStream Module through the DI pin (pin 4) as an asynchronous serial signal. The signal should idle high when no data is being transmitted.

The UART performs tasks, such as timing and parity checking, that are needed for data communications. Serial communication consists of two UARTs configured with compatible parameters (baud rate, parity, start bits, stop bits, data bits) to have successful communication.

Each data packet consists of a start bit (low), 8 data bits (least significant bit first) and a stop bit

(high). The following figure illustrates the serial bit pattern of data passing through the module.

Figure 202. UART data packet 0x1F (decimal number “31”) as transmitted through the XStream

Module

Example Data Format is 8‐N‐1 (bits – parity ‐ # of stop bits)

© 2014 Digi International Inc.

10

XStream™ OEM RF Module – Product Manual v5.x00

2.1.2. Flow Control

Figure 203. Internal Data Flow Diagram (The five most commonly‐used pin signals shown.)

DI (Data In) Buffer and Flow Control

When serial data enters the XStream Module through the DI Pin (pin 4), then the data is stored in the DI Buffer until it can be transmitted.

When the RB and RO parameter thresholds are satisfied (refer to Transmit Mode section (p11) and command descriptions for more information), the module attempts to initialize an RF connection. If the module is already receiving RF data, the serial data is stored in the DI Buffer.

The size of the DI Buffer can be determined by issuing the RZ (DI Buffer Size) Command. If the

DI buffer becomes full, hardware or software flow control must be implemented in order to prevent overflow (loss of data between the host and XStream Module).

How to eliminate the need for flow control:

1. Send messages that are smaller than the DI buffer size. The size of the DI buffer varies according to the packet size (PK parameter) and the parity setting (NB parameter) used.

2. Interface at a lower baud rate (BD parameter) than the fixed RF data rate.

Two cases in which the DI Buffer may become full and possibly overflow:

1. If the serial interface data rate is set higher than the RF data rate of the module, the module will receive data from the host faster than it can transmit the data over-the-air.

2. If the module is receiving a continuous stream of RF data or monitoring data on a network, any serial data that arrives on the DI pin is placed in the DI Buffer. The data in the DI buffer will be transmitted over-the-air when the module no longer detects RF data in the network.

Hardware Flow Control ( ). When the DI buffer is 17 bytes away from being full; by default, the module de-asserts (high) to signal to the host device to stop sending data (refer to FT

(Flow Control Threshold) and CS (DO2 Configuration) Commands).

Buffer has 34 bytes of memory available. is re-asserted after the DI

Software Flow Control (XON). XON/XOFF software flow control can be enabled using the FL

(Software Flow Control) Command. This option only works with ASCII data.

DO (Data Out) Buffer and Flow Control

When RF data is received, the data enters the DO buffer and is then sent out the serial port to a host device. Once the DO Buffer reaches capacity, any additional incoming RF data is lost. The size of the DO Buffer can be determined by issuing the RZ (DI Buffer Size) Command, then multiplying the result by 1.5.

Two cases in which the DO Buffer may become full and possibly overflow:

1. If the RF data rate is set higher than the interface data rate of the module, the module will receive data from the transmitting module faster than it can send the data to the host.

2. If the host does not allow the module to transmit data out from the DO buffer because of being held off by hardware or software flow control.

Hardware Flow Control ( ). If be sent out the DO Buffer as long as is enabled for flow control (RT Parameter = 2), data will not

(pin 5) is de-asserted

© 2014 Digi International Inc.

11

XStream™ OEM RF Module – Product Manual v5.x00

Software Flow Control (XOFF). XON/XOFF software flow control can be enabled using the FL

(Software Flow Control) Command. This option only works with ASCII data.

2.2. Modes of Operation

XStream OEM RF Modules operate in five modes.

Figure 204. XStream Modes of Operation

The module can only be in one mode at a time.

2.2.1. Idle Mode

When not receiving or transmitting data, the module is in Idle Mode. The module uses the same amount of power in Idle Mode as it does in Receive Mode.

The module shifts into the other modes of operation under the following conditions:

Serial data is received in the DI Buffer (Transmit Mode)

Valid RF data is received through the antenna (Receive Mode)

Command Mode Sequence is issued (Command Mode)

Sleep Mode condition is met (Sleep Mode)

After responding to any of the preceding conditions, the module automatically transitions back into Idle Mode.

2.2.2. Transmit Mode

After the first byte of serial data is received in the DI buffer (from the

UART), the module attempts to shift to Transmit Mode and initiate RF connections with other modules. After transmission is complete, the module returns to Idle Mode.

Note: RF reception must complete before the module is able to enter into Transmit

Mode. RF transmission begins after either of the following criteria is

met:

1. RB bytes have been received in the DI buffer and are pending for RF transmission (refer to

RB (Packetization Threshold) Command, p29).

The RB parameter may be set to any value between 1 and the RF packet size (PK), inclusive.

When RB = 0, the packetization threshold is ignored.

2. At least one character has been received in the DI buffer (pending for RF transmission) and

RO time has been observed on the UART (refer to RO (Packetization Timeout) Command).

The timeout can be disabled by setting RO to zero. In this case, transmission will begin after

RB bytes have been received in the DI buffer.

© 2014 Digi International Inc.

12

XStream™ OEM RF Module – Product Manual v5.x00

After either RB or RO conditions are met, the module then initializes a communications channel. (Channel Initialization is the process of sending an RF initializer that synchronizes receiving modules with the transmitting module. During channel initialization, incoming serial data accumulates in the DI buffer.)

Serial data in the DI buffer is grouped into RF packets (refer to PK (RF Packet Size)); converted to RF data; then transmitted over-the-air until the DI buffer is empty.

RF data, which includes the payload data, follows the RF initializer. The payload includes up to the maximum packet size (PK Command) bytes. As the transmitting module nears the end of the transmission, it inspects the DI buffer to see if more data exists to be transmitted. This could be the case if more than PK bytes were originally pending in the DI buffer or if more bytes arrived from the UART after the transmission began. If more data is pending, the transmitting module assembles a subsequent packet for transmission.

Figure 205. Data Transmission Sequence

RF Data Packet

Figure 206. RF Data Packet

* When streaming multiple RF packets, the RF Initializer is only sent in front of the first packet.

RF Initializer

An RF initializer is sent each time a new connection sequence begins. The RF initializer contains channel information that notifies receiving modules of information such as the hopping pattern used by the transmitting module. The first transmission always sends an RF initializer.

An RF initializer can be of various lengths depending on the amount of time determined to be required to prepare a receiving module. For example, a wake-up initializer is a type of RF initializer used to wake remote modules from Sleep Mode (Refer to the FH, LH, HT and SM

© 2014 Digi International Inc.

13

XStream™ OEM RF Module – Product Manual v5.x00

Commands for more information). The length of the wake-up initializer should be longer than the length of time remote modules are in cyclic sleep.

Header

The header contains network addressing information that filters incoming RF data. The receiving module checks for a matching Hopping Channel (HP parameter), Vendor Identification Number

(ID parameter) and Destination Address (DT parameter). Data that does not pass through all three network filter layers is discarded.

CRC (Cyclic Redundancy Check)

To verify data integrity and provide built-in error checking, a 16-bit CRC (Cyclic Redundancy

Check) is computed for the transmitted data and attached to the end of each RF packet. On the receiving end, the receiving module computes the CRC on all incoming RF data. Received data that has an invalid CRC is discarded. (See Receive Mode section.)

2.2.3. Receive Mode

If the module detects RF data while in Idle Mode, the module transitions into Receive

Mode to receive RF packets. Once a packet is received, the module checks the CRC to ensure that the data was transmitted without error. If the CRC data bits on the incoming packet are invalid, the packet is discarded. If the CRC is valid, the packet proceeds to the DO Buffer.

The module returns to Idle Mode when valid

RF data is no longer detected or after an error is detected in the received RF data.

Figure 207. Data Reception Sequence Æ

* Refer to the Addressing section (p36) of the

RF Communication Modes chapter for more information regarding address recognition.

Note: If serial data exists in the DI buffer while the module is in Receive Mode, the UART data will be transmitted after the module is finished receiving the RF data and has returned to Idle Mode.

2.2.4. Sleep Mode

© 2014 Digi International Inc.

Sleep Modes enable the XStream Module to operate at minimal power consumption when not in use. Three Sleep Mode options are available:

Pin Sleep (Host Controlled)

Serial Port Sleep (Wake on Serial Port activity)

Cyclic Sleep (Wake on RF activity)

For the module to transition into Sleep Mode, the module must have a non-zero SM

(Sleep Mode) Parameter and one of the following must occur:

1. The module is idle (no data transmission or reception) for a user-defined period of time (See

ST (Time before Sleep) Command)

2. DI3 (pin 2) is asserted (only for Pin Sleep option)

14

XStream™ OEM RF Module – Product Manual v5.x00

In Sleep Mode, the module will not transmit or receive data until the module first transitions to Idle Mode. All Sleep Modes are enabled and disabled using SM Command.

Transitions into and out of Sleep Modes are triggered by various mechanisms as shown in the table below.

Table 201. Summary of Sleep Mode Configurations

Sleep Mode

Setting

Pin Sleep

(SM = 1)

Serial Port Sleep

(SM = 2)

Cyclic Sleep

(SM = 3-8)

Transition into

Sleep Mode

Microcontroller can shut down and wake modules by asserting (high) SLEEP (pin 2).

Note: Module will complete transmission / reception before activating Pin Sleep.

Automatic transition to Sleep Mode occurs after a user-defined period of inactivity (no transmitting or receiving of data). The period of activity is defined using the ST

(Time before Sleep) Command.

Automatic transition to Sleep Mode occurs in cycles as defined by the SM (Sleep

Mode) Command.

Note: The cyclic sleep time interval must be shorter than the “Wake-up Initializer Timer”

(set by LH Command).

Transition out of

Sleep Mode

De-assert (low)

SLEEP (pin 2).

When serial byte is received on the DI pin

(pin 4).

After the cyclic sleep time interval elapses.

Note: Module can be forced into Idle Mode if PW (Pin Wake-up)

Command is issued.

Related

Commands

SM

SM, ST

SM, ST, HT,

LH, PW

Typical Power

Consumption

26 µA

1 mA

76 µA when sleeping

For more information about Sleep Modes, refer to the individual commands listed in “Related Commands” column of the table. The SM command is central to all Sleep Mode configurations.

Pin Sleep (SM = 1)

Pin Sleep requires the least amount of power. In order to achieve this state, SLEEP pin must be asserted (high). The module remains in Pin Sleep until the SLEEP pin is de-asserted.

After enabling Pin Sleep Mode, the SLEEP pin controls whether the module is active or in Sleep

Mode. When SLEEP is de-asserted (low), the module is fully operational. When SLEEP is asserted

(high), the module transitions to Sleep Mode and remains in its lowest power-consuming state until the SLEEP pin is de-asserted. SLEEP is only active if the module is setup to operate in this mode; otherwise the pin is ignored.

Once in Pin Sleep Mode, is de-asserted (high), indicating that data should not be sent to the module. The PWR pin is also de-asserted (low) when the module is in Pin Sleep Mode.

Note: The module will complete a transmission or reception before activating Pin Sleep.

Serial Port Sleep (SM = 2)

Serial Port Sleep is a Sleep Mode in which the XStream Module runs in a low power state until serial data is detected on the DI pin.

When Serial Port Sleep is enabled, the module goes into Sleep Mode after a user-defined period of inactivity (no transmitting or receiving of data). This period of time is determined by ST (Time before Sleep) Command. Once a character is received through the DI pin, the module returns to

Idle Mode and is fully operational.

Cyclic Sleep (SM = 3-8)

Cyclic Sleep is the Sleep Mode in which the XStream Module enters into a low-power state and awakens periodically to determine if any transmissions are being sent.

When Cyclic Sleep settings are enabled, the XStream Module goes into Sleep Mode after a user- defined period of inactivity (no transmission or reception on the RF channel). The user-defined period is determined by ST (Time before Sleep) Command.

While the module is in Cyclic Sleep Mode, is de-asserted (high) to indicate that data should not be sent to the module during this time. When the module awakens to listen for data, is asserted and any data received on the DI Pin is transmitted. The PWR pin is also de-asserted

(low) when the module is in Cyclic Sleep Mode.

© 2014 Digi International Inc.

15

XStream™ OEM RF Module – Product Manual v5.x00

The module remains in Sleep Mode for a user-defined period of time ranging from 0.5 seconds to

16 seconds (SM Parameters 3 through 8). After this interval of time, the module returns to Idle

Mode and listens for a valid data packet for 100 ms. If the module does not detect valid data (on any frequency), the module returns to Sleep Mode. If valid data is detected, the module transitions into Receive Mode and receives incoming RF packets. The module then returns to

Sleep Mode after a Period of inactivity that is determined by ST “Time before Sleep” Command.

The module can also be configured to wake from cyclic sleep when SLEEP (pin 2) is de-asserted

(low). To configure a module to operate in this manner, PW (Pin Wake-up) Command must be issued. Once SLEEP is de-asserted, the module is forced into Idle Mode and can begin transmitting or receiving data. It remains active until no data is detected for the period of time specified by the ST Command, at which point it resumes its low-power cyclic state.

Note: The cyclic interval time defined by SM (Sleep Mode) Command must be shorter than the interval time defined by LH (Wake-up Initializer Timer).

For example: If SM=4 (Cyclic 1.0 second sleep), the LH Parameter should equal 0x0B (“1.1” seconds). With these parameters set, there is no risk of the receiving module being asleep for the duration of wake-up initializer transmission. “Cyclic Scanning” explains in further detail the relationship between “Cyclic Sleep” and “Wake-up Initializer Timer”

Cyclic Scanning. Each RF transmission consists of an RF Initializer and payload. The wake-up initializer contains initialization information and all receiving modules must wake during the wake-up initializer portion of data transmission in order to be synchronized with the transmitting module and receive the data.

Figure 208. Correct Configuration (LH > SM)

Length of the wake‐up initializer exceeds the time interval of Cyclic Sleep. The receiver is guaranteed to detect the wake‐up initializer and receive the accompanying payload data.

Figure 209. Incorrect Configuration (LH < SM)

Length of wake‐up initializer is shorter than the time interval of Cyclic Sleep. This configuration is vulnerable to the receiver waking and missing the wake‐up initializer (and therefore also the accompanying payload data).

© 2014 Digi International Inc.

16

XStream™ OEM RF Module – Product Manual v5.x00

2.2.5. Command Mode

To modify or read module parameters, the module must first enter into Command Mode (a state in which incoming characters are interpreted as commands). Two command types are supported:

AT Commands

Binary Commands

AT Commands

To Enter AT Command Mode:

1. Send the 3-character command sequence “+++” and observe guard times before and after the command characters. (Refer to the “Default AT Command Mode Sequence” below.) The

“Terminal” tab (or other serial communications software) of the XCTU Software can be used to enter the sequence.

(OR)

2. Assert (low) the CONFIG pin and either turn the power going to the module off and back on.

(If using a Digi XIB-R Interface Board, the same result can be achieved by keeping the configuration switch pressed while turning off, then on again the power supplying the module assembly (module assembly = module mounted to an interface board))

Default AT Command Mode Sequence (for transitioning to Command Mode):

No characters sent for one second (BT (Guard Time Before) parameter = 0x0A)

Input three plus characters (“+++”) within one second (CC (Command Sequence Character)

Command = 0x2B-0)

No characters sent for one second (AT (Guard Time After) parameter = 0x0A)

To Send AT Commands:

Send AT commands and parameters using the syntax shown below.

Figure 210. Syntax for sending AT Commands

The preceding example would change the module Destination Address to “0x1F”. For modified parameter values to persist in the module registry, changes must be saved to non-volatile memory using WR (Write) Command. Otherwise, parameters are restored to previously saved values after the module is powered off and then on again.

Note: To read the current value of a module parameter, leave the parameter field blank. For example, the following command will return the current destination address: ATDT<CR>

System Response. When a command is sent to the module, the module will parse and execute the command. Upon successful execution of a command, the module returns an “OK” message. If execution of a command results in an error, the module returns an “ERROR” message.

To Exit AT Command Mode:

1. Send ATCN (Exit Command Mode) Command.

(OR)

2. If no valid AT Commands are received within the time specified by CT (Command Mode

Timeout) Command, the Module automatically returns to Idle Mode.

For an example that illustrates programming the module using AT Commands, refer to the

Module Configuration chapter (p18).

© 2014 Digi International Inc.

17

XStream™ OEM RF Module – Product Manual v5.x00

Binary Commands

Sending and receiving parameter values using binary commands is the fastest way to change operating parameters of the module. Binary commands are used most often to sample signal strength (RS parameter) and/or error counts; or to change module addresses and channels for polling systems when a quick response is necessary. Since the sending and receiving of parameter values takes place through the same serial data path as “live” data (received RF payload), interference between the two types of data can be a concern.

Common questions about using binary commands:

What are the implications of asserting CMD while live data is being sent or received?

After sending serial data, is there a minimum time delay before CMD can be asserted?

Is a time delay required after CMD is de-asserted before payload data can be sent?

How does one discern between live data and data received in response to a command?

The CMD pin (pin 5) must be asserted in order to send binary commands to the module. The

CMD pin can be asserted to recognize binary commands anytime during the transmission or reception of data. The status of the CMD signal is only checked at the end of the stop bit as the byte is shifted into the serial port. The application does not allow control over when data is received, except by waiting for dead time between bursts of communication.

CMD (pin 5) must be asserted in order to send binary commands to an XStream Module. CMD can be asserted to recognize commands anytime during transmission or reception of data. A minimum time delay of 100 µs (after the stop bit of the command byte has been sent) must be observed before pin 5 can be de-asserted. The command executes after all parameters associated with the command have been sent. If all parameters are not received within 0.5 seconds, the module aborts the command and returns to Idle Mode. Note: When parameters are sent, they are always two bytes long with the least significant byte sent first.

Commands can be queried for their current value by sending the command logically ORed with the value 0x80 (hexadecimal) with CMD asserted. When the binary value is sent (with no parameters), the current value of the command parameter is sent back through the DO pin.

Figure 211. Binary Command Write then Read

Signal #4 is CMD (pin 5)

Signal #1 is the DIN (pin 4) signal to the radio

Signal #2 is the DOUT (pin 3) signal from the radio

Signal #3 is (pin 1)

In this graph, a value was written to a register and then read out to verify it. While not in the middle of other received data, note that the signal outlines the data response out of the module.

IMPORTANT: For the XStream Module to recognize a binary command, RT (DI2 Configuration)

Command must be issued. If binary programming is not enabled (RT ≠ 1), the module will not recognize that the CMD pin (Pin 5) is asserted and therefore will not recognize the data as binary commands.

© 2014 Digi International Inc.

18

XStream™ OEM RF Module – Product Manual v5.x00

3. RF Module Configuration

3.1. Hands-on Programming Examples

For information about entering and exiting AT and Binary Command Modes, refer to the

Command Mode section (p16).

3.1.1. AT Command Example

To Send AT Commands (Using the Terminal tab of Digi’s XCTU Software)

Example: Both of the following examples change the module’s destination address to 0x1A0D and save the new address to non-volatile memory.

Method 1 (One line per command)

Send AT Command

+++

ATDT <Enter>

ATDT1A0D <Enter>

ATWR <Enter>

ATCN <Enter>

System Response

OK <CR> (Enter into Command Mode) current Destination Address <CR> (Read)

OK <CR> (Change destination address)

OK <CR> (Write to non-volatile memory)

OK <CR> (Exit Command Mode)

Method 2 (Multiple commands on one line)

Send AT Command

+++

ATDT <Enter>

ATDT1A0D,WR,CN <Enter>

System Response

OK <CR> (Enter into Command Mode) current Destination Address <CR> (Read)

OK <CR> (Execute commands)

Digi’s XCTU Software facilitates module programming. To install, double-click the “setup_X-CTU.exe” file that is located at www.digi.com.

Note: In order to use a host PC and the XCTU Software Terminal tab to send data to the module, PC com port settings must match the baud, parity and stop bit parameters stored in the module.

Use the “PC Settings” tab to configure PC com port settings to match module parameter values.

© 2014 Digi International Inc.

19

XStream™ OEM RF Module – Product Manual v5.x00

3.1.3. Binary Command Example

To Send Binary Commands:

Example: Use binary commands to change the XStream Module’s destination address to 0x1A0D and save the new address to non-volatile memory.

1. RT Command must be set to “1” in AT Command Mode to enable binary programming.

2. Assert CMD (Pin 5 is driven high). (Enter Binary Command Mode)

3. Send Bytes (parameter bytes must be 2 bytes long):

00 (Send DT (Destination Address) Command)

0D (Least significant byte of parameter bytes)

1A (Most significant byte of parameter bytes)

08 (Send WR (Write) Command)

4. De-assert CMD (Pin 5 is driven low) (Exit Binary Command Mode)

Note: (pin 1) is de-asserted high when commands are being executed. Hardware flow control must be disabled as will hold off parameter bytes.

© 2014 Digi International Inc.

20

XStream™ OEM RF Module – Product Manual v5.x00

3.2. Command Reference Table

Table 301. XStream Commands (The module expects numerical values in hexadecimal. “d” denotes decimal equivalent.)

AT

Command

AM v4.30*

AT

BD v4.2B*

IU v4.30*

LH

MD v4.30*

MK

MY v4.30*

NB v4.30*

PC v4.22*

PK v4.30*

PW v4.22*

RB v4.30*

RE

RN v4.22*

RO v4.2A*

RP v4.2A*

RR v4.22*

RS v4.22*

Binary

Command AT Command Name

0x3A (58d) Auto-set MY

0x05 (5d) Guard Time After

0x15 (21d)

0x3B (59d) DI2, DI3 Update Timer

0x0C (12d) Wake-up Initializer Timer

0x32 (50d)

0x12 (18d)

RF Mode

Address Mask

0x2A (42d) Source Address

0x23 (35d) Parity

0x1E (30d) Power-up Mode

0x29 (41d) RF Packet Size

0x1D (29d) Pin Wake-up

0x20 (32d) Packetization Threshold

0x0E (14d) Restore Defaults

0x19 (25d)

0x21 (33d)

0x22 (34d)

0x18 (24d)

0x16 (22d)

Delay Slots

0x1C (28d) RSSI

DI2 Configuration

0x2C (44d) DI Buffer Size

SB v4.2B* 0x36 (54d)

SH v4.27C* 0x25 (37d)

0x26 (38d)

0x01 (1d)

0x02 (2d)

0x17 (23d)

0x31 (49d)

Baud Rate

BK v4.30*

BO v4.30*

BT

CB v4.30*

CC

CD v4.2B*

CE v4.30*

CF v4.30*

0x2E (46d)

0x30 (48d)

0x04 (4d)

0x33 (51d)

0x13 (19d)

0x28 (40d)

CL v4.30*

CM v4.30*

CN

CO v4.30*

0x34 (52d)

0x35 (53d)

0x39 (57d)

0x38 (56d)

0x09 (9d)

0x2F (47d)

CS v4.27D* 0x1F (31d)

CT

Serial Break Passing

Serial Break Timeout

Guard Time Before

Connection Duration Timeout

Command Sequence Character

DO3 Configuration

Connection Inactivity Timeout

Connection Failure Count

Last Connection Address

Connection Message

Exit AT Command Mode

E1

ER

FH

FL

DC v4.30*

DR v4.30*

DT

E0

0x06 (6d)

0x37 (55d)

DO3 Timeout

DO2 Configuration

Command Mode Timeout

Disconnect

0x2D (45d) DI3 Configuration

0x00 (0d) Destination Address

0x0A (10d) Echo Off

0x0B (11d) Echo On

0x0F (15d) Receive Error Count

0x0D (13d) Force Wake-up Initializer

0x07 (7d)

FT v4.27B* 0x24 (36d)

GD

HP

HT

0x10 (16d)

0x11 (17d)

0x03 (3d)

Software Flow Control

Flow Control Threshold

Receive Good Count

Hopping Channel

Time before Wake-up Initializer

ID v4.2B*

RT

RZ v4.30*

SL v4.27C*

SM

ST

SY

TO v4.30*

TR v4.22*

TT v4.22*

VR

WR

0x27 (39d) Modem VID

Packetization Timeout

RSSI PWM Timer

Retries

Stop Bits

Serial Number High

Serial Number Low

Sleep Mode

Time before Sleep

Time before Initialization

DO2 Timeout

0x1B (27d) Transmit Error Count

0x1A (26d) Streaming Limit

0x14 (20d)

0x08 (8d)

Firmware Version

Write

Range

-

0x02 – 0xFFFF (x 100 msec)

Standard baud rates: 0 – 6

(custom rates also supported)

-

0 – 4

0 – 0xFFFF

-

-

0 – 0xFFFF

-

0 – 1

0 – 0xFF (bytes)

0 – 0xFFFF

0 – 6

0 – 0xFFFF (x 100 msec)

User-settable: 0x10 - 0x7FFF

Read-only: 0x8000 – 0xFFFF

0 - 0xFFFF (x 100 msec)

0 – 0xFF (x 100 msec)

0 – 4

0 – 0xFFFF

0 – 0xFFFF

0 – 5

0 – 1

0 - 0x100 (bytes)

0 – 1

0 - 0x100 (bytes)

-

0 – 0xFF (slots)

0 – 0xFFFF (x 200 µsec)

0 - 0x7F (x 100 msec)

0 – 0xFF

0x06 – 0x36 (read-only)

0 - 2

(read-only)

0 - 1

0 – 0xFFFF (read-only)

0 – 0xFFFF (read-only)

0 – 8

0 - 0xFFFF (x 1 sec)

0 – 0xFFFF

0 – 0xFFFF (0 = disabled)

0 x 0xFFFF (read-only)

-

Command Category

Networking and Security

Command Mode Options

Serial Interfacing

0 – 1

0 - 0xFFFF (x 1 second)

Serial Interfacing

Serial Interfacing

0 – 0xFFFF (x 100 msec) Command Mode Options

0x01 – 0xFFFF (x 100 msec) Networking and Security

0x20 – 0x7F

0 – 4

0 – 0xFFFF (x 10 msec)

0 – 0xFFFF

(read-only)

0 – 1

-

0 - 0xFFFF (x 1 second)

0 – 4 Serial Interfacing

0x02 – 0xFFFF (x 100 msec) Command Mode Options

0x10 – 0xFFFF (x 100 msec) Sleep (Low Power)

0 – 0xFF (x 100 msec)

Command Mode Options

Serial Interfacing

Networking and Security

Networking and Security

Diagnostics

Networking and Security

Command Mode Options

Serial Interfacing

Networking and Security

Serial Interfacing

Networking and Security

Command Mode Options

Command Mode Options

Diagnostics

Sleep (Low Power)

Serial Interfacing

Serial Interfacing

Diagnostics

Networking and Security

Sleep (Low Power)

Networking and Security

Serial Interfacing

Sleep (Low Power)

Networking and Security

Networking and Security

Networking and Security

Serial Interfacing

Command Mode Options

Serial Interfacing

Sleep (Low Power)

Serial Interfacing

(Special)

Networking and Security

Serial Interfacing

Diagnostics

Networking and Security

Diagnostics

Serial Interfacing

Diagnostics

Serial Interfacing

Diagnostics

Diagnostics

Sleep (Low Power)

Networking and Security

Serial Interfacing

Diagnostics

Networking and Security

Diagnostics

(Special)

# Bytes

Returned

-

2

2

2

1

2

1

1

2

1

-

2

2

2

2

-

1

1

2

1

-

1

1

2

1

2

2

1

1

2

2

1

2

-

1

1

2

-

2

2

1

2

2

1

1

2

2

1

2

2

2

-

1

1

2

-

2

2

-

* Firmware version in which command and parameter options were first supported.

Note: AT Commands issued without a parameter value will return the currently stored parameter.

© 2014 Digi International Inc.

Factory

Default

-

0

0

-

-

0

0

0xC8 (200d)

-

0 varies

0

0

0xFFFF

-

0x0A (10d) factory-set

RF data rate

0

0

0x0A (10d)

0x28 (4d sec)

0x2B (“+”)

0

0x64 (1d sec)

0

-

0

-

0x03

-

0

-

0

-

-

0

0x64 (100d)

0 (disabled)

0x03

0

0xFFFF

-

-

0

-

0

0

-

0

0

0x01

0x0A (10d)

0x01

0

0xFFFF

0xFFFF

0

0

0x40 (64d)

21

XStream™ OEM RF Module – Product Manual v5.x00

3.3. XStream Command Descriptions

Command descriptions in this section are listed alphabetically. Command categories are designated within “< >” symbols that follow each command title. XStream Modules expect parameter numerical values in hexadecimal (designated by the “0x” prefix).

AM (Auto-set MY) Command

<Networking and Security> AM Command is used to automatically set the MY (Source

AT Command: ATAM

Binary Command: 0x3A (58 decimal)

Minimum firmware version required: 4.40

Address) parameter from the factory-set module serial number. The address is formed with bits 29, 28 and 13-0 of the serial number (in that order).

AT (Guard Time After) Command

AT Command: ATAT

Binary Command: 0x05 (5 decimal)

<Command Mode Options> AT Command is used to set the DI time-of-silence that follows the AT command sequence character (CC Command).

By default, AT Command Mode will activate after one second of silence.

Refer to the AT Commands section (p16) to view the default AT Command Mode Sequence.

(x 100 milliseconds)

Number of bytes returned: 2

Default Parameter Value: 0x0A (10 decimal)

CC (Command Sequence Character)

BD (Interface Data Rate) Command

<Serial Interfacing> BD Command allows the user to adjust the UART interface data rate and thus modify the rate at which serial data is sent to the RF module. The new baud rate does not take effect until the CN command is issued. The

RF data rate is unaffected by the BD parameter.

Most applications will require one of the seven standard baud rates; however, non-standard baud rates are also supported.

Note: If the interface data rate is set to exceed the fixed RF data rate of the module, flow control may need to be implemented as described in the Pin Signals (p6), Flow Control

(p10) and CS (DO2 Configuration) sections.

AT Command: ATBD

Binary Command: 0x15 (21 decimal)

Parameter Range (Standard baud rates): 0 – 6

(Non-standard baud rates): 0x7D – 0xFFFF

Parameter

0

1

2

3

4

5

6

Configuration (bps)

1200

2400

4800

9600

19200

38400

57600

Number of bytes returned: 2

Default Parameter Value: Set to equal module’s

factory-set RF data rate.

Related Commands: CN (Exit Command Mode)

Non-standard Interface Data Rates: When parameter values outside the range of standard interface data rates are sent, the closest rate represented by the number is stored in the BD register. For example, a rate of 19200 bps can be set by sending the following command line

"ATBD4B00". Note: When using Digi’s XCTU Software, non-standard interface data rates can only be set and read using the XCTU “Terminal” tab.

When the BD command is sent with a non-standard interface data rate, the UART will adjust to accommodate the requested interface rate. In most cases, the clock resolution will cause the stored BD parameter to vary from the parameter that was sent (refer to the table below).

Reading the BD command (send "ATBD" command without an associated parameter value) will return the value that was actually stored in the BD register.

Table 302. Parameter Sent vs. Parameter Stored

BD Parameter Sent (HEX)

0

4

7

12C

1C200

Interface Data Rate (bps)

1200

19,200

115,200

300

115,200

BD Parameter Stored (HEX)

0

4

7

12B

1B207

© 2014 Digi International Inc.

22

XStream™ OEM RF Module – Product Manual v5.x00

BK (Serial Break Passing) Command

<Serial Interfacing> Pass a serial break condition on the DI pin to the DO pin of another module.

BO (Serial Break Timeout) Command

<Serial Interfacing> DO pin will return to default after no serial break status information is received during the timeout period.

Use with BK parameter = 1.

AT Command: ATBK

Binary Command: 0x2E (46 decimal)

Parameter Range: 0 – 1

Parameter

0

1

Configuration disable enable

Default Parameter Value: 0

Number of bytes returned: 1

Related Commands: BO (Serial Break Timeout)

Minimum Firmware Version Required: 4.30

AT Command: ATBO

Binary Command: 0x30 (48 decimal)

Parameter Range: 0 – 0xFFFF (x 1 second)

Default Parameter Value: 0

Number of bytes returned: 2

Related Commands: BK (Serial Break Passing)

Minimum Firmware Version Required: 4.30

BT (Guard Time Before) Command

<Command Mode Options> BT Command is used to set the DI pin silence time that must precede the command sequence character (CC

Command) of the AT Command Mode Sequence.

Refer to the AT Commands section (p16) to view the default AT Command Mode sequence.

AT Command: ATBT

Binary Command: 0x04 (4 decimal)

Default Parameter Value: 0x0A (10 decimal)

Number of bytes returned: 2

CB (Connection Duration Timeout) Command

<Networking and Security> Set/Read the maximum amount of time an exclusive connection between a base and remote module in a point-to-multipoint network is sustained. The remote module will disconnect when this timeout expires.

CC (Command Sequence Character) Command

<Command Mode Options> CC Command is used to set the ASCII character to be used between

Guard Times of the AT Command Mode Sequence

(BT+ CC + AT). The AT Command Mode

Sequence activates AT Command Mode (from

Idle Mode).

Refer to the AT Commands section (p16) to view the default AT Command Mode sequence.

AT Command: ATCB

Binary Command: 0x33 (51 decimal)

Default Parameter Value: 0x28 (4d seconds)

Number of bytes returned: 2

Related Commands: CE (Connection Inactivity

Timeout), DC (Disconnect), MD (RF Mode)

Minimum Firmware Version Required: 4.30

AT Command: ATCC

Binary Command: 0x13 (19 decimal)

Parameter Range: 0x20 – 0x7F

Default Parameter Value: 0x2B (ASCII “+” sign)

Number of bytes returned: 1

Related Commands: AT (Guard Time After), BT

(Guard Time Before)

© 2014 Digi International Inc.

23

XStream™ OEM RF Module – Product Manual v5.x00

CD (DO3 Configuration) Command

<Serial Interfacing> CD Command is used to redefine the behavior of the DO3 (Data Output

3)/RX LED line.

CE (Connection Inactivity Timeout) Command

<Networking and Security> Set/Read the duration of inactivity that will cause a break in a connection between modules. The base module will disconnect when no payload has been transferred for the time specified by the CE parameter.

AT Command: ATCD

Binary Command: 0x28 (40 decimal)

Parameter Range: 0 – 4

Parameter

0

1

2

3

Configuration

RX LED

Default high

Default low

(reserved)

4

Assert only when packet addressed to module sent

Default Parameter Value: 0

Number of bytes returned: 1

Minimum Firmware Version Required: 4.2B

AT Command: ATCE

Binary Command: 0x34 (52 decimal)

(x 10 milliseconds)

Default Parameter Value: 0x64 (1d second)

Number of bytes returned: 2

Related Commands: CB ( Connection Duration

Timeout), DC (Disconnect), MD (RF Mode)

Minimum Firmware Version Required: 4.30

CF (Connection Failure Count) Command

<Diagnostics> Set/Read the number of times the base module expired retries attempting to send a

Connection Grant Packet. Set to zero to clear the register.

AT Command: ATCF

Binary Command: 0x35 (53 decimal)

Parameter Range: 0 – 0xFFFF

Default Parameter Value: 0

Number of bytes returned: 2

Minimum Firmware Version Required: 4.30

CL (Last Connection Address) Command

<Diagnostics/Networking and Security> Read the address of the remote module that last connected to the base module. A remote module will return its DT (Destination Address) parameter.

AT Command: ATCL

Binary Command: 0x39 (57 decimal)

Parameter Range: 0 – 0xFFFF (read-only)

Number of bytes returned: 2

Minimum Firmware Version Required: 4.30

CM (Connection Message) Command

<Networking and Security> Select whether base sends connect messages to the host when a connection is established. When enabled, a

“CONNECTXXXX” string is sent to the host of the base module. “XXXX” is the MY (Source Address) of the connected remote module.

AT Command: ATCM

Binary Command: 0x38 (56 decimal)

Parameter Range: 0 – 1

Parameter

0

1

Configuration enable disable

Default Parameter Value: 0

Number of bytes returned: 1

Minimum Firmware Version Required: 4.30

© 2014 Digi International Inc.

24

XStream™ OEM RF Module – Product Manual v5.x00

CN (Exit AT Command Mode) Command

<Command Mode Options> CN Command is used to explicitly exit AT Command Mode.

AT Command: ATCN

Binary Command: 0x09 (9 decimal)

CO (DO3 Timeout) Command

<Serial Interfacing> DO3 (Data Output 3) output will return to default after no DI3 (Data Input 3) status information is received during the timeout period.

Use with CD = 1 or 2, DR = 1.

AT Command: ATCO

Binary Command: 0x2F (47 decimal)

Parameter Range: 0 – 0xFFFF (x 1 second)

Default Parameter Value: 3

Number of bytes returned: 2

Related Commands: CD (DO3 Configuration),

DR (DI3 Configuration)

Minimum Firmware Version Required: 4.30

CS (DO2 Configuration) Command

<Serial Interfacing> CS Command is used to select the behavior of the DO2 (Data Output 2) pin signal. This output can provide RS-232 flow control, control the TX enable signal (for RS-485 or RS-422 operations), or set the default level for the I/O line passing function.

By default, DO2 provides RS-232

Send) flow control.

(Clear-to-

CT (Command Mode Timeout) Command

<Command Mode Options> CT Command is used to set the amount of time of inactivity before AT

Command Mode automatically terminates. After a

CT time of inactivity, the module exits AT

Command Mode and returns to Idle Mode. AT

Command Mode can also be exited manually using the CN (Exit AT Command Mode)

Command.

AT Command: ATCS

Binary Command: 0x1F (31 decimal)

Parameter Range: 0 – 4

Parameter

0

1

2

3

4

Default Parameter Value: 0

Configuration

RS-232 flow control

RS-485 TX enable low high

RS-485 TX enable high low

Number of bytes returned: 1

Related Commands: RT (DI2 Configuration),

TO (DO2 Timeout)

Minimum Firmware Version Required: 4.27D

AT Command: ATCT

Binary Command: 0x06 (6 decimal)

Parameter Range: 2 – 0xFFFF

(x 100 milliseconds)

Number of bytes returned: 2

DC (Disconnect) Command

<Networking and Security> DC Command is used (when in Multi-Streaming Mode (MD = 1 or 2)) to explicitly force the disconnection of an active exclusive connection. If MD = 1, the base module will force the disconnection of an exclusive connection. If MD = 2, the remote module will send a “Disconnect Request Packet” to the base module.

AT Command: ATDC

Binary Command: 0x37 (55 decimal)

Related Commands: CB (Connection Duration

Timeout), CE (Connection Inactivity Timeout),

MD (RF Mode)

Minimum Firmware Version Required: 4.30

© 2014 Digi International Inc.

25

XStream™ OEM RF Module – Product Manual v5.x00

DR (DI3 Configuration) Command

<Serial Interfacing> DR Command is used to configure DI3 (pin 2, SLEEP) for I/O line passing

(use with CD = 1 or 2 and CO) or controlling connection status (use with MD = 1 or 2).

AT Command: ATDR

Binary Command: 0x2D (45 decimal)

Parameter Range: 0 – 4

Parameter

0

1

2

Configuration

Disabled

DI3 I/O passing enabled

Connect on low

3

4

Disconnect on high

Connect and Disconnect

Default Parameter Value: 0

Number of bytes returned: 1

Related Commands: CD (DO3 Configuration),

CO (DO3 Timeout), MD (RF Mode)

Minimum Firmware Version Required: 4.30

DT (Destination Address) Command

<Networking and Security> DT Command is used to set the networking address of an

XStream Module. XStream Modules use three filtration layers: Channels (ATHP), Vendor

Identification Number (ATID) and Destination

Addresses (ATDT). DT Command assigns an address to a module that enables it to communicate only with other modules having the

AT Command: ATDT

Binary Command: 0x00

Parameter Range: 0 – 0xFFFF

Default Parameter Value: 0

Number of bytes returned: 2

Related Commands: HP (Hopping Channel), ID

(Module VID), MK (Address Mask) same addresses. All modules that share the same Destination Address can communicate freely with each other.

Modules in the same network with a different Destination Address (than that of the transmitter) will listen to all transmissions to stay synchronized, but will not send any of the data out their serial ports.

E0 (Echo Off) Command

<Command Mode Options> The E0 command turns off character echo in AT Command Mode.

By default, echo is off.

AT Command: ATE0

Binary Command: 0x0A (10 decimal)

E1 (Echo On) Command

<Command Mode Options> E1 Command turns on the echo in AT Command Mode. Each typed character will be echoed back to the terminal when ATE1 is active. E0 is the default.

AT Command: ATE1

Binary Command: 0x0B (11 decimal)

ER (Receive Error Count) Command

<Diagnostics> Set/Read the receive error count.

The error-count records the number of packets

AT Command: ATER

Binary Command: 0x0F (15 decimal) partially received then aborted on reception error. This value returns to 0 after a reset and is

Parameter Range: 0 – 0xFFFF

Default Parameter Value: 0 not non-volatile (value does not persist in the module’s memory after a power-up sequence).

Number of bytes returned: 2

Once the receive error count reaches its

Related Commands: GD (Receive Good Count) maximum value (up to 0xFFFF), it remains at its maximum count value until the maximum count value is explicitly changed or the module is reset.

© 2014 Digi International Inc.

26

XStream™ OEM RF Module – Product Manual v5.x00

FH (Force Wake-up Initializer) Command

<Sleep (Low Power)> FH Command is used to force a Wake-up Initializer to be sent on the next transmission. WR (Write) Command does not need to be issued with FH Command.

AT Command: ATFH

Binary Command: 0x0D (13 decimal)

Use only with cyclic sleep modes active on remote modules.

FL (Software Flow Control) Command

<Serial Interfacing> FL Command is used to configure of module with software flow control.

Hardware flow control is implemented with the

XStream Module as the DO2 pin ( ), which regulates when serial data can be transferred to the module. FL Command is used to allow software flow control. XON character used is

0x11 (17 decimal). XOFF character used is 0x13

(19 decimal).

AT Command: ATFL

Binary Command: 0x07 (7 decimal)

Parameter Range: 0 – 1

Parameter

0

1

Configuration

Disable software flow control

Enable software flow control

Default Parameter Value: 0

Number of bytes returned: 1

FT (Flow Control Threshold) Command

<Serial Interfacing> Set/Read the flow control threshold. When FT bytes have accumulated in the DI buffer, is de-asserted or the XOFF software flow control character is transmitted.

AT Command: ATFT

Binary Command: 0x24 (36 decimal)

Parameter Range: 0 – 0xFF (bytes)

(Maximum value equals the receiving module

DO buffer size minus 0x11 bytes)

Default Parameter Value: Receiving module DO

Buffer size minus 0x11

Number of bytes returned: 2

Minimum Firmware Version Required: 4.27B

GD (Receive Good Count) Command

<Diagnostics> Set/Read the count of good AT Command: ATGD received RF packets. Parameter value is reset to

Binary Command: 0x10 (16 decimal)

0 after every reset and is not non-volatile (value

Parameter Range: 0 – 0xFFFF does not persist in the module’s memory after a

Default Parameter Value: 0 power-up sequence). Once the “Receive Good

Count” reaches its maximum value (up to

0xFFFF), it remains at its maximum count value

Number of bytes returned: 2

Related Commands: ER (Receive Error Count) until the maximum count value is manually changed or the module is reset.

HP (Hopping Channel) Command

<Networking and Security> HP Command is used to set the module hopping channel number.

A channel is one of three layers of addressing available to the module. In order for modules to

AT Command: ATHP

Binary Command: 0x11 (17 decimal)

Parameter Range: 0 – 6 communicate with each other, the modules must have the same channel number since each network uses a different hopping sequence.

Different channels can be used to prevent

Default Parameter Value: 0

Number of bytes returned: 1

Related Commands: DT (Destination Address),

ID (Module VID), MK (Address Mask) modules in one network from listening to transmissions of another.

© 2014 Digi International Inc.

27

XStream™ OEM RF Module – Product Manual v5.x00

HT (Time before Wake-up Initializer) Command

<Sleep (Low Power)> If any modules within range are running in a “Cyclic Sleep” setting, a wake-up initializer must be used by the transmitting module for sleeping modules to remain awake (refer to the LH (“Wake-up

Initializer Timer”) Command). When a receiving module in Cyclic Sleep wakes, it must detect the wake-up initializer in order to remain awake and

AT Command: ATHT

Binary Command: 0x03 (3 decimal)

(x 100 milliseconds)

Default Parameter Value: 0xFFFF (means that

long wake-up initializer will not be sent)

Number of bytes returned: 2

Related Commands: LH (Wake-up Initializer

Timer), SM (Sleep Mode), ST (Time before

Sleep) receive data. The value of HT Parameter tells the transmitter, “After a period of inactivity (no transmitting or receiving) lasting HT amount of time, send a long wake-up initializer”. HT

Parameter should be set to match the inactivity timeout (specified by ST (Time before Sleep)

Command) used by the receiver(s).

From the receiving module perspective, after HT time elapses and the inactivity timeout (ST command) is met, the receiver goes into cyclic sleep. In cyclic sleep, the receiver wakes once per sleep interval to check for a wake-up initializer. When a wake-up initializer is detected, the module will stay awake to receive data. The wake-up initializer must be longer than the cyclic sleep interval to ensure that sleeping modules detect incoming data. When HT time elapses, the transmitter then knows that it needs to send a long Wake-up Initializer for all receivers to be able to remain awake and receive the next transmission. Matching HT to the time specified by ST on the receiving module guarantees that all receivers will detect the next transmission.

ID (Modem VID) Command

<Networking and Security> Set/Read the VID

(Vendor Identification Number). Only modules with matching VIDs can communicate with each other. Modules with non-matching VIDs will not receive unintended data transmission.

AT Command: ATID

Binary Command: 0x27 (39 decimal)

Parameter Range (user-settable):

0x10 - 0x7FFFF

(Factory-set and read-only) :

0x8000 – 0xFFFF

Number of bytes returned: 2

Minimum Firmware Version Required: 4.2B

(previous firmware versions did not support user-settable IDs.)

IU (DI2, DI3 Update Timer) Command

<Serial Interfacing> Set/Read the interval at which the status of DI2, DI3 and Break is transmitted. Additionally, status is transmitted whenever there is a transition. A setting of “0” disables periodic update. DI2 or DI3 passing must be enabled for the update to take place.

AT Command: ATIU

Binary Command: 0x3B (59 decimal)

Parameter Range: 0 - 0xFFFF (x 100 ms)

Default Parameter Value: 0x0A (10 decimal)

Number of bytes returned: 2

Related Commands: BK (Serial Break Passing),

BO (Serial Break Timeout), CO (DO3 Timeout),

DR (Disconnect), RT (DI2 Configuration), TO

(DO2 Timeout)

Minimum Firmware Version Required: 4.30

© 2014 Digi International Inc.

28

XStream™ OEM RF Module – Product Manual v5.x00

LH (Wake-up Initializer Timer) Command

<Sleep (Low Power)> Set/Read the amount of time during which the RF initializer is sent. When receiving modules are put into Cyclic Sleep Mode, they power-down after a period of inactivity

(specified by ST (Time before Sleep) Command) and will periodically awaken and listen for transmitted data. In order for the receiving modules to remain awake, they must detect

~35ms of the wake-up initializer.

AT Command: ATLH

Binary Command: 0x0C (12 decimal)

Default Parameter Value: 1

Number of bytes returned: 1

LH Command must be used whenever a receiver is operating in Cyclic Sleep Mode. This lengthens the Wake-up Initializer to a specific amount of time (in tenths of a second). The Wake-up

Initializer Time must be longer than the cyclic sleep time that is determined by SM (Sleep Mode)

Command. If the wake-up initializer time were less than the Cyclic Sleep interval, the connection would be at risk of missing the wake-up initializer transmission.

Refer to the figures in the Sleep Mode sections (p13) to view correct and incorrect configuration diagrams. The images help visualize the importance that the LH value be greater than the SM cyclic sleep value.

MD (RF Mode) Command

<Networking and Security> The MD command is used to select/read the RF Mode (Peer-to-peer,

Multi-Stream or Repeater Modes) of the module.

Multi-Streaming Mode enables exclusive connections in point-to-multipoint networks.

Refer to the Multi-Streaming Mode section (p43) for more information regarding how these parameter values affect other parameter values.

Repeater Mode enables longer range via an intermediary module. When MD=3, the module will act as a “store and forward” repeater. Any packets not addressed to this node will be repeated. A Repeater End Node (MD=4) handles repeated messages, but will not forward the data over-the-air. Refer to the Repeater Mode section

(p38) for more information.

AT Command: ATMD

Binary Command: 0x32 (50 decimal)

Parameter Range: 0 – 4

Parameter Configuration

0

1

2

3

4

(transparent operation)

Multi-Stream Base

Multi-Stream Remote

Repeater and End Node

End Node

Default Parameter Value: 0

Number of bytes returned: 1

Related Commands: CB (Connection Duration

Timeout), CE (Connection Inactivity Timeout),

CM (Connection Message), DC (Disconnect)

Minimum Firmware Version Required: 4.30

MK (Address Mask) Command

<Networking and Security> MK Command is used to set/read the address mask of the module.

All data packets contain the destination address

(DT Parameter) of the transmitting module.

When an RF data packet is received, the transmitter’s destination address is logically

AT Command: ATMK

Binary Command: 0x12 (18 decimal)

Parameter Range: 0 – 0xFFFF

Default Parameter Value: 0xFFFF

(Destination address (DT parameter) of the transmitting module must exactly match the destination address of the receiving module.)

“ANDed” (bitwise) with the Address Mask of the receiver. The resulting value must match the destination address or the address mask of the receiver for the packet to be received and sent

Number of bytes returned: 2

Related Commands: DT (Destination Address),

HP (Hopping Channel), ID (Module VID), MY

(Source Address) out the module DO serial port. If the “ANDed” value does not match either the destination address or the address mask of the receiver, the packet is discarded. (All “0” values are treated as “irrelevant” values and are ignored.)

Refer to the Addressing Options section (p36) for more information.

© 2014 Digi International Inc.

29

XStream™ OEM RF Module – Product Manual v5.x00

MY (Source Address) Command

<Networking and Security> Set/Read the source address of the module.

Refer to the Addressing section (p36) of the RF

Communication Modes chapter for more information.

AT Command: ATMY

Binary Command: 0x2A (42 decimal)

Parameter Range: 0 – 0xFFFF

Default Parameter Value: 0xFFFF (Disabled – the DT (Destination Address) parameter serves as both source and destination address.)

Number of bytes returned: 2

Related Commands: DT (Destination Address),

HP (Hopping Channel), ID (Modem VID), MK

(Address Mask), AM (Auto-set MY)

Minimum Firmware Version Required: 4.30

NB (Parity) Command

<Serial Interfacing> Select/Read parity settings for UART communications.

PC (Power-up Mode) Command

<Command Mode Options> PC Command allows the module to power-up directly into AT

Command Mode from reset or power-on. If PC

Command is enabled with SM Parameter set to 1,

DI3 (pin 2) can be used to enter the module into

AT Command Mode. When the DI3 pin is de- asserted (low), the module will wake-up in AT

Command Mode. This behavior allows module

DTR emulation.

AT Command: ATNB

Binary Command: 0x23 (35 decimal)

Parameter Range: 0 – 5

Parameter

0

1

2

3

4

5

Configuration

8-bit (no parity or

7-bit (any parity)

8-bit even

8-bit odd

8-bit mark

8-bit space

9-bit

Default Parameter Value: 0

Number of bytes returned: 1

Minimum Firmware Version Required: 4.30

(previous versions did not support the 9 th bit.

AT Command: ATPC

Binary Command: 0x1E (30 decimal)

Parameter Range: 0 – 1

Parameter

0

Configuration

Power-up to Idle Mode

1

Default Parameter Value: 0

Number of bytes returned: 1

Minimum Firmware Version Required: 4.22

PK (RF Packet Size) Command

<Serial Interfacing> Set/Read the maximum size of the RF packets sent out a transmitting module. The maximum packet size can be used along with the RB and RO parameters to implicitly set the channel dwell time.

Changes to this parameter may have a secondary effect on the RB (Packet Control

Characters) parameter. RB must always be less than or equal to PK. If PK is changed to a value

AT Command: ATPK

Binary Command: 0x29 (41 decimal)

Parameter Range: 0 – 0x100 (Bytes)

Default Parameter Value: 0x40 (64 decimal)

Number of bytes returned: 2

Related Commands: RB (Packetization

Threshold), RO (Packetization Timeout)

Minimum Firmware Version Required: 4.30 less than the current value of RB, RB is automatically lowered to be equal to PK.

© 2014 Digi International Inc.

30

XStream™ OEM RF Module – Product Manual v5.x00

PW (Pin Wake-up) Command

<Sleep (Low Power)> Under normal operation, a module in Cyclic Sleep Mode cycles from an active state to a low-power state at regular intervals until data is ready to be received. If the

PW Parameter is set to 1, SLEEP (pin 2) can be used to wake the module from Cyclic Sleep. If the

SLEEP pin is de-asserted (low), the module will be fully operational and will not go into Cyclic

Sleep. Once SLEEP is asserted, the module will remain active for the period of time specified by

ST (Time before Sleep) Command and will return to Cyclic Sleep Mode (if no data is ready to be transmitted). PW Command is only valid if Cyclic

Sleep has been enabled.

AT Command: ATPW

Binary Command: 0x1D (29 decimal)

Parameter Range: 0 – 1

Parameter

0

1

Configuration

Disabled

Enabled

Default Parameter Value: 0

Number of bytes returned: 1

Minimum Firmware Version Required: 4.22

RB (Packetization Threshold) Command

<Serial Interfacing> RF transmission will commence when data is in the DI Buffer and

AT Command: ATRB

Binary Command: 0x20 (32 decimal) either of the following criteria are met: Parameter Range: 0 – 0x100 (bytes)

RO times out on the UART receive lines

(ignored if RO = 0)

(Maximum value equals the current value of PK

Parameter (up to 0x100 HEX (800 decimal))

RB characters have been received by the

UART (ignored if RB = 0)

If PK is lowered below the value of RB; RB is automatically lowered to match PK.

Default Parameter Value: 1

Number of bytes returned: 2

Related Commands: PK (RF Packet Size), RO

(Packetization Timeout)

Minimum Firmware Version Required: 4.30

Note: RB and RO criteria only apply to the first packet of a multi-packet transmission. If data remains in the DI Buffer after the first packet, transmissions will continue in streaming manner until there is no data left in the DI Buffer (UART receive buffer).

RE (Restore Defaults) Command

<Diagnostics> RE Command restores all AT Command: ATRE configurable parameters to factory default Binary Command: 0x0E (14 decimal) settings. However, RE Command will not write the restored values to non-volatile (persistent) memory. Issue the WR (Write) Command after the RE command to save restored parameter values to non-volatile memory.

RN (Delay Slots) Command

<Networking and Security> RN Command is only applicable if retries have been enabled (RR

(Retries) parameter > 0), or if forced delays will be inserted into a transmission (TT (Streaming

AT Command: ATRN

Binary Command: 0x19 (25 decimal)

Parameter Range: 0 – 0xFF (slots)

Default Parameter Value: 0

(no delay slots are inserted)

Limit) parameter > 0). RN Command is used to adjust the time delay that the transmitter inserts before attempting to resend a packet. If the transmitter fails to receive an acknowledgement

Number of bytes returned: 1

Related Commands: RR (Retries), TT

(Streaming Limit) after sending a packet, it will insert a random

Minimum Firmware Version Required: 4.22

number of delay slots (ranging from 0 to (RN minus 1)) before attempting to resend the packet. Each delay slot lasts for a period of 38ms.

If two modules attempted to transmit at the same time, the random time delay after packet failure would allow one of the two modules to transmit the packet successfully, while the other would wait until the channel opens up to begin transmission.

© 2014 Digi International Inc.

31

XStream™ OEM RF Module – Product Manual v5.x00

RO (Packetization Timeout) Command

<Serial Interfacing> Set/Read the time of silence

(no bytes received) after which transmission begins. After a serial byte is received and if no other byte is received before the RO timeout, the transmission will start.

AT Command: ATRO

Binary Command: 0x21 (33 decimal)

Parameter Range: 0 – 0xFFFF (x 200 µs)

Default Parameter Value: 0

Number of bytes returned: 2

Minimum Firmware Version Required: 4.2A

RP (RSSI PWM Timer) Command

<Diagnostics> RP Command is used to enable

PWM (Pulse Width Modulation) output on the

CONFIG pin. The output is calibrated to show the level the received RF signal is above the

AT Command: ATRP

Binary Command: 0x22 (34 decimal)

Parameter Range: 0 - 0x7F

(x 100 milliseconds)

Default Parameter Value: 0 (disabled) sensitivity level of the module. The PWM pulses vary from zero to 95 percent. Zero percent means the received RF signal is at or below the

Number of bytes returned: 1

Minimum Firmware Version Required: 4.2A

published sensitivity level of the module. The following table shows levels above sensitivity and PWM values.

The total period of the PWM output is 8.32 ms. Because there are 40 steps in the PWM output; the minimum step size is 0.208 ms.

Table 3‐03. PWM Chart

dBm above Sensitivity

10

20

30

PWM percentage

(high period / total period)

47.5%

62.5%

77.5%

A non-zero value defines the time that the PWM output will be active with the RSSI value of the last received RF packet. After the set time when no RF packets are received, the PWM output will be set low (0 percent PWM) until another RF packet is received. The PWM output will also be set low at power-up. A parameter value of 0xFF permanently enables the PWM output and it will always reflect the value of the last received RF packet.

PWM output shares the Config input pin. When the module is powered, the Config pin will be an input. During the power-up sequence, the Config pin will be read to determine whether the module is going into AT Command Mode. After this, if RP parameter is a non-zero value, the

Config pin will be configured as an output and set low until the first RF packet is received. With a non-zero RP parameter, the Config pin will be an input for RP ms after power up.

RR (Retries) Command

<Networking> Set/Read the number of retries that can be sent for a given RF packet. Once RR

AT Command: ATRR

Binary Command: 0x18 (24 decimal) command is enabled (set to a non-zero value),

RF packet acknowledgements and retries are

Parameter Range: 0 – 0xFF enabled. After transmitting a packet, the transmitter will wait to receive an

Default Parameter Value: 0 (disabled)

Number of bytes returned: 1 acknowledgement from a receiver. If the

Minimum Firmware Version Required: 4.22

acknowledgement is not received in the period of time specified by the RN (Delay Slots)

Command, the transmitter will transmit the original packet again. The packet will be transmitted repeatedly until an acknowledgement is received or until the packet has been sent RR times.

Note: For retries to work correctly, all modules in the system must have retries enabled.

© 2014 Digi International Inc.

32

XStream™ OEM RF Module – Product Manual v5.x00

RS (RSSI) Command

<Diagnostics> Read the signal level of the last packet received. This reading is useful for determining range characteristics of the modules under various conditions of noise and distance.

Once the command is issued, the module will return a value between 0x06 and 0x36.

(“0x36” represents a very strong signal level and “0x06” indicates a low signal level.)

AT Command: ATRS

Binary Command: 0x1C (28 decimal)

Parameter Range: 0x06 – 0x36 (read-only)

Number of bytes returned: 1

Minimum Firmware Version Required: 4.22

RT (DI2 Configuration) Command

<Serial Interfacing> RT command is used to dictate the behavior of the DI2/ /CMD line. RT

Command must be issued to enable control or binary programming. flow

RZ (DI Buffer Size) Command

<Diagnostics> The RZ command is used to read the size of the DI buffer (UART RX (Receive)).

Note: The DO buffer size can be determined by multiplying the DI buffer size by 1.5.

SB (Stop Bits) Command

<Serial Interfacing> Set/Read the number of stop bits in the RF data packets.

SH (Serial Number High) Command

<Diagnostics> Set/Read the serial number high word of the module.

AT Command: ATRT

Binary Command: 0x16 (22 decimal)

Parameter Range: 0 – 2

Parameter

0

1

2

Configuration disabled

Enable Binary Programming

Enable Flow Control

Default Parameter Value: 0

Number of bytes returned: 1

AT Command: ATRZ

Binary Command: 0x2C (44 decimal)

Parameter Range: Read-only

Number of bytes returned: 2

Minimum Firmware Version Required: 4.30

AT Command: ATSB

Binary Command: 0x36 (54 decimal)

Parameter Range: 0 – 1

Parameter

0

1

Configuration

1 stop bits

2 stop bits

Default Parameter Value: 0

Number of bytes returned: 1

Minimum Firmware Version Required: 4.2B

AT Command: ATSH

Binary Command: 0x25 (37 decimal)

Parameter Range: 0 – 0xFFFF (read-only)

Number of bytes returned: 2

Related Commands: SL (Serial Number Low)

Minimum Firmware Version Required: 4.27C

© 2014 Digi International Inc.

33

XStream™ OEM RF Module – Product Manual v5.x00

SL (Serial Number Low) Command

<Diagnostics> Set/Read the serial number low word of the module.

AT Command: ATSH

Binary Command: 0x26 (38 decimal)

Parameter Range: 0 – 0xFFFF (read-only)

Number of bytes returned: 2

Related Commands: SH (Serial Number High)

Minimum Firmware Version Required: 4.27C

SM (Sleep Mode) Command

<Sleep Mode (Low Power)> Set/Read Sleep Mode

Settings. By default, Sleep Mode is disabled and the module remains continually active.

SM Command allows the module to run in a lower-power state and to be configured in one of eight settings.

Cyclic Sleep settings wake the module after the amount of time designated by SM Command. If the module detects a wake-up initializer during the time it is awake, it will synchronize with the transmitter and start receiving data after the wake-up initializer runs its duration. Otherwise, it returns to Sleep Mode and continues to cycle in and out of inactivity until the Wake-up Initializer is detected. If a Cyclic Sleep setting is chosen, the ST, LH and HT parameters must also be set as described in the “Sleep Mode” section of this manual.

Refer to the Sleep Mode sections for more information.

AT Command: ATSM

Binary Command: 0x01

Parameter Range: 0 – 8

Parameter

0

1

2

3

4

5

6

7

8

Configuration

Disabled

Pin Sleep

Serial Port Sleep

Cyclic 0.5 second sleep

(Module wakes every 0.5 seconds)

Cyclic 1.0 second sleep

Cyclic 2.0 second sleep

Cyclic 4.0 second sleep

Cyclic 8.0 second sleep

Cyclic 16.0 second sleep

Default Parameter Value: 0

Number of bytes returned: 1

Related Commands:

Pin Sleep – PC (Power-up Mode), PW (Pin

Wake-up)

Serial Port Sleep – ST (Time before Sleep)

Cyclic Sleep – ST (Time before Sleep), LH

(Wake-up Initializer Timer), HT (Time Before

Wake-up Initializer), PW (Pin Wake-up)

ST (Time before Sleep) Command

<Sleep Mode (Low Power)> Set/Read the period of time in which the module remains inactive before entering into Sleep Mode. For example: If the ST parameter is set to 0x64 (100 decimal), the module will enter into Sleep mode after 10 seconds of inactivity (no transmitting or receiving). This command can only be used if

Cyclic Sleep or Serial Port Sleep Mode settings have been selected using the SM command.

AT Command: ATST

Binary Command: 0x02

Parameter Range: 0x10 – 0xFFFF

(x 100 milliseconds)

Default Parameter Value: 0x64 (100 decimal)

Number of bytes returned: 2

Related Commands: SM (Sleep Mode), LH

(Wake-up Initializer Timer), HT (Time before

Wake-up Initializer)

© 2014 Digi International Inc.

34

XStream™ OEM RF Module – Product Manual v5.x00

SY (Time before Initialization) Command

<Networking and Security> SY Command keeps a communication channel open as long as module transmits or receives before the active connection expires. It can be used to reduce latency in a query/response sequence and should be set 100 ms longer than the delay between transmissions.

This command allows multiple XStream Modules

AT Command: ATSY

Binary Command: 0x17 (23 decimal)

Parameter Range: 0 – 0xFF

(x 100 milliseconds)

Default Parameter Value: 0 (Disabled - channel

initialization info sent with each RF packet.)

Number of bytes returned: 1 to share a hopping channel for a given amount of time after receiving data. By default, all packets include an RF initializer that contains channel information used to synchronize any listening receivers to the transmitter’s hopping pattern. Once a new module comes within range, it is able to instantly synchronize to the transmitter and start receiving data. If no new modules are introduced into the system, the synchronization information becomes redundant once modules have become synchronized.

SY Command allows the modules to remove this information from the RF Initializer after the initial synchronization. For example, changing the SY Parameter to 0x14 (20 decimal) allows all modules to remain in sync for 2 seconds after the last data packet was received. Synchronization information is not re-sent unless transmission stops for more than 2 seconds. This command allows significant savings in packet transmission time.

Warning: Not recommended for use in an interference-prone environment. Interference can break up the session and the communications channel will not be available again until SY time expires.

With SY set to zero, the channel session is opened and closed with each transmission - resulting in a more robust link with more latency.

TO (DO2 Timeout) Command

<Serial Interfacing>DO2 output will return to default after no DI2 status information is received during the timeout period.

Use with CS = 2 or 4.

AT Command: ATTO

Binary Command: 0x31 (49 decimal)

Parameter Range: 0 – 0xFFFF (x 1 second)

Default Parameter Value: 3

Number of bytes returned: 2

Minimum Firmware Version Required: 4.30

TR (Transmit Error Count) Command

<Diagnostics> Read number of retransmit failures. The number of retransmit errors is incremented each time a packet is not acknowledged within the number of retransmits specified by the RR (Retries) parameter. It therefore counts the number of packets that were not successfully received and have been dropped.

AT Command: ATTR

Binary Command: 0x1B (27 decimal)

Parameter Range: 0 – 0xFFFF

Default Parameter Value: 0

Number of bytes returned: 2

Related Commands: RR (Retries)

Minimum Firmware Version Required: 4.22

The TR parameter is not non-volatile and therefore is reset to zero each time the module is reset.

© 2014 Digi International Inc.

35

XStream™ OEM RF Module – Product Manual v5.x00

TT (Streaming Limit) Command

<Networking and Security> Set/Read the number of bytes that can be sent out before a random delay is issued. TT Command is used to simulate full-duplex behavior.

If a module is sending a continuous stream of RF data, a delay is inserted (transmission is stopped,

AT Command: ATTT

Binary Command: 0x1A (26 decimal)

Parameter Range: 0 – 0xFFFF (bytes)

Default Parameter Value: 0xFFFF (65535d)

Number of bytes returned: 2

Related Commands: RN (Delay Slots)

Minimum Firmware Version Required: 4.22 allowing other modules time to transmit (once it sends number of bytes specified by TT Command). Inserted random delay lasts between 1 and ‘RN

+ 1’ delay slots, where each delay slot lasts 38 ms.

VR (Firmware Version) Command

<Diagnostics> Read the Firmware Version of the module.

AT Command: ATVR

Binary Command: 0x14 (20 decimal)

Parameter Range: 0 – 0xFFFF (read-only)

Number of bytes returned: 2

WR (Write) Command

<(Special)> WR Command writes configurable parameters to the module’s non-volatile memory

AT Command: ATWR

Binary Command: 0x08

(Parameter values remain in the module’s memory until overwritten by future use of WR Command).

If changes are made without writing them to non-volatile memory, the module reverts back to previously saved parameters the next time the module is powered-on.

© 2014 Digi International Inc.

36

XStream™ OEM RF Module – Product Manual v5.x00

4. RF Communication Modes

Network configurations covered in this chapter are described in terms of the following:

Network Topology (Point-to-Point, Point-to-Multipoint or Peer-to-Peer)

RF Communication Type (Basic or Acknowledged)

RF Mode (Streaming, Repeater, Acknowledged or Multi-Streaming)

The following table provides a summary of the network configurations supported.

Table 401. Summary of network configurations supported by the XStream OEM RF Module

Point-to-Point

Definition

Sample Network Profile *

(Broadcast Communications)

Sample Network Profile *

(Acknowledged Communications)

Basic Communication RF Modes

Acknowledged Communication RF Mode

An RF data link between two modules.

Use default values for all modules.

All Modules: ATAM (auto-set MY (Source Address) parameter) **

ATDT FFFF (set Destination Address to 0xFFFF)

Streaming Mode (p37), Repeater Mode (p38)

Acknowledged Mode (p41)

Point-to-Multipoint

Definition RF data links between one base and multiple remotes.

Base: ATMY 0 (set Source Address to 0x00)

ATDT FFFF (set Destination Address to 0xFFFF) Sample Network Profile *

(Basic Communications)

Remotes: ATAM (auto-set MY (Source Address) parameter) **

ATDT 0 (set Destination Address to 0x00)

Base: ATMY 0 (set Source Address to 0x00)

ATDT FFFF (set Destination Address to 0xFFFF)

ATRR 3 (set number of Retries to 3) Sample Network Profile *

(Acknowledged Communications)

Basic Communication RF Modes

Remotes: ATAM (auto-set MY (Source Address) parameter) **

ATDT 0 (set Destination Address to 0x00)

ATRR 3 (set number of Retries to 3)

Streaming Mode (p37), Repeater Mode (p38)

Acknowledged Communication RF Modes Acknowledged Mode (p41), Multi-Streaming Mode (p43)

Peer-to-Peer

Definition

Sample Network Profile *

(Basic Communications)

Modules remain synchronized without use of a master/server. Each module shares the roles of master and slave. Digi’s peer-to-peer architecture features fast synch times (35ms to synchronize modules) and fast cold start times (50ms before transmission).

Use default values for all modules.

Sample Network Profile *

(Acknowledged Communications)

Basic Communication RF Mode

Acknowledged Communication RF Mode

All Modules: ATAM (auto-set MY (Source Address) parameter) **

ATDT FFFF (set Destination Address to 0xFFFF)

ATRR 3 (set number of Retries to 3)

Streaming Mode (p37)

Acknowledged Mode (p41)

* Assume default values for parameters not listed. Profiles do not reflect addressing implementations.

** AM (Auto‐set MY) Command must be issued through a terminal program such as the one incorporated in the XCTU “Terminal” tab.

© 2014 Digi International Inc.

37

XStream™ OEM RF Module – Product Manual v5.x00

4.1. Addressing

Each RF packet contains addressing information that is used to filter incoming RF data. Receiving modules inspect the Hopping Channel (HP parameter), Vendor Identification Number (ID parameter) and Destination Address (DT parameter) contained in each RF packet. Data that does not pass through all three network security layers is discarded.

Figure 401. Filtration layers contained in the RF packet header

4.1.1. Address Recognition

Transmissions can be addressed to a specific module or group of modules using the DT

(Destination Address) and MK (Address Mask) parameters. The transmitting module dictates whether the packet is intended for a specific module (local address) or multiple modules (global address) by comparing the packet’s DT parameter to its own MK parameter.

Figure 402. Local Packets vs. Global Packets (Transmitting Module)

TX_DT = Transmitter Destination Address

TX_MK = Transmitter Address Mask

Note: When TX_DT = 0xFFFF (default), RF packets are global and are received by all modules within range. (Receivers do not send

ACKs.)

A receiving module will only accept a packet if a packet is addressed to it (either as a global or local packet). The RX module makes this determination by inspecting the destination address of the RF packet and comparing it to its own address and mask. The Destination Address of the TX module is logically “ANDed” with the Address Mask of the RX module.

Figure 403. Address Recognition (Receiving Module)

TX_DT = Transmitter Destination Address

RX_DT = Receiver Destination Address

RX_MY = Receiver Source Address

Note: For more information regarding addressing and masks, refer to Application Note “XST-

AN004b” (located on the web at: www.digi.com.)

© 2014 Digi International Inc.

38

XStream™ OEM RF Module – Product Manual v5.x00

4.2. Basic Communications

Basic Communications are accomplished through two sub-types:

Broadcast - By default, XStream Modules communicate through Broadcast communications and within a peer-to-peer network topology. When any module transmits, all other modules within range will receive the data and pass it directly to their host device.

Addressed - If addressing parameters match, received RF data is forwarded to the DO (Data

Out) buffer; otherwise, the RF data is discarded.

When using Basic Communications, any functions such as acknowledgements are handled at the application layer by the OEM/integrator. The Broadcast Modes provide transparent communications, meaning that the RF link simply replaces a wired link.

4.2.1. Streaming Mode (Default)

Characteristics: Highest data throughput

Lowest latency and jitter

Reduced immunity to interference

Transmissions never acknowledged (ACK) by receiving module(s)

Required Parameter Values (TX Module): RR (Retries) = 0

Related Commands: Networking (DT, MK, MY), Serial Interfacing (PK, RB, RO, TT)

Recommended Use: Mode is most appropriate for data systems more sensitive to latency and/or jitter than to occasional packet loss. For example: streaming audio or video.

Streaming Mode Data Flow

Figure 404. Streaming Mode State Diagram (TX Module)

Events and processes in this mode are common to all of the

other RF Modes.

Note: When streaming data, RB and RO parameters are only observed on the first packet.

After transmission begins, the TX event will continue uninterrupted until the DI buffer is empty or the streaming limit

(TT Command) is reached. As with the first packet, the payload of each subsequent packet includes up to the maximum packet size (PK Command).

The streaming limit (TT Command) is specified by the transmitting module as the maximum number of bytes the transmitting module can send in one transmission event. After the TT parameter threshold is reached, the transmitting module will force a random delay of 1 to RN delay slots (exactly 1 delay slot if RN = 0).

Subsequent packets are sent without an RF initializer since receiving modules stay synchronized with the transmitting module for the duration of the transmission event (from preceding packet information). However, due to interference, some receiving modules may lose data (and synchronization to the transmitting module), particularly during long transmission events.

© 2014 Digi International Inc.

39

XStream™ OEM RF Module – Product Manual v5.x00

Once the transmitting module has sent all pending data or has reached the TT limit, the transmission event ends. The transmitting module will not transmit again for exactly RN delay slots if the local (i.e. transmitting module’s) RN parameter is set to a non-zero value. The receiving module(s) will not transmit for a random number of delay slots between 0 and (RN-1) if the local (i.e. receiving module’s) RN parameter is set to a non-zero value. These delays are intended to lessen congestion following long bursts of packets from a single transmitting module, during which several receiving modules may have become ready to transmit.

4.2.2. Repeater Mode

Characteristics: Self-organizing - No route configuration is necessary

Self-healing / Fault-tolerant

Low power consumption and Minimized interference

Network throughput is determined by number of hops, not by number of repeaters. Multiple repeaters within range of source node count as one hop.

Supports “transparent” multi-drop mode or addressed data filtering mode.

Duplicate RF packets are automatically filtered out.

All packets propagate to every node in the network (filtering rules apply).

Broadcast communications - each packet comes out every node exactly once.

Addressed communications - all radios see every packet. Only the module with a matching address will forward it to the DO buffer (UART IN).

Data entering the network on any module is transmitted and forwarded through every repeater module until it reaches the ends of the network.

Each repeater will repeat a packet only once.

Constraints: Requires that each module have a unique MY (Source Address) parameter.

System must introduce just one packet at a time to the network for transmission (256 bytes max).

Each hop (H) decreases network throughput by a factor of 1/(H+1).

Additional repeaters add network redundancy without decreasing throughput.

Required Parameter Values (TX Module): MD = 3 or 4, MY = unique value (can be accomplished by issuing the AM (Auto-set MY) and WR (Write) commands to all modules in the network)

Related Commands: Networking (MD, DT, MY, AM), Serial Interfacing (RN, PK, RO, RB)

Recommended Use: Use in networks where intermediary nodes are needed to relay data to modules that are beyond the transmission range of the base module.

Theory of Operation

OEMs and integrators can extend the effective range and reliability of a data radio system by forwarding traffic through one or more repeaters.

Instead of using routing tables and path discovery to establish dynamic paths through a network, the repeater system uses a sophisticated algorithm to propagate each RF packet through the entire network.

The network supports RF packets up to 256 bytes. The repeater network can operate using broadcast or addressed communications for multi-drop networks and works well in many systems with no special configuration.

When in Repeater Mode, the network repeats each message among all available nodes exactly one time. This mechanism eliminates the need for configuring specific routes. The network is self- organizing and self-healing so that the system is able to receive transmissions in the event of a module going down.

© 2014 Digi International Inc.

40

XStream™ OEM RF Module – Product Manual v5.x00

Figure 405. Sample Repeater Network Topology

Repeater Network Configuration

A network may consist of End Nodes (EN), End/Repeater Nodes (ERN) and a Base Node (BN).

The base node initiates all communications.

The repeater network can be configured to operate using Basic Broadcast or Basic Addressed communications. The addressing capabilities of the modules allow integrators to send a packet as a global packet (DT = 0xFFFF) and shift out of every radio in the network (Basic Broadcast).

Alternatively, the packet can be sent with a specific DT (Destination Address) parameter so that it is only accepted by a specific remote node (Basic Addressed).

Configuration Instruction (Basic Broadcast Communications)

Assign each module a unique MY (source) address. (The AM (Auto-set MY) command will configure a unique source address that is based on module serial number.)

Enable Basic Broadcast Communications (DT = 0xFFFF) or Addressed Broadcast Communications

(ATDT specifies a specific destination)

Configure PK, RO and RB to ensure that RF packet aligns with protocol packet. (ex. PK=0x100,

RB=0x100, RO depends on baud rate).

Configure one or more repeaters in the system (ATMD = 3).

Configure remote nodes as destinations (MD = 4). This will ensure that the remote node waits for the repeater traffic to subside before it transmits a response.

Assign each module a unique MY (source) address. (The AM (Auto-set MY) command will configure a unique source address that is based on module serial number.)

Enable Basic Broadcast Communications (DT = 0xFFFF) or Addressed Broadcast Communications

(ATDT specifies a specific destination)

Configure PK, RO and RB to ensure that RF packet aligns with protocol packet. (ex. PK=0x100,

RB=0x100, RO depends on baud rate).

Configure one or more repeaters in the system (ATMD = 3).

Configure remote nodes as destinations (MD = 4). This will ensure that the remote node waits for the repeater traffic to subside before it transmits a response.

The configuration instructions above reflect configuration for a Basic Broadcast Repeater system.

To configure a Basic Addressed Repeater system, use the DT (Destination Address) parameter to assign unique addresses to each module in the network.

Algorithm details

Packet ID (PID) is composed of transmitting module MY address and packet serial number.

Incoming packets with a PID already found in the PID buffer will be ignored.

Each module maintains a PID buffer 8 deep of previously received packets (managed as

FIFO).

Packets may be shifted out the serial port and/or repeated depending on the DT parameter contained in the RF packet.

© 2014 Digi International Inc.

41

XStream™ OEM RF Module – Product Manual v5.x00

Table 402. DT (Destination Address) parameter truth

table

Address Match

Global

Local

None

Send out serial port?

Yes

Yes

No

Repeat?

Yes

No

Yes

Repeat delay based on RSSI

A transmitted packet may be received by more that one repeater at the same time. In order to reduce the probability that the repeaters will transmit at the same instant, resulting in a collision and possible data loss; an algorithm has been developed that will allow a variable back-off prior to retransmission of the packet by a repeater. The algorithm allows radios that receive the packet with a stronger RF signal (RSSI) to have the first opportunity to retransmit the packet.

The RN (Delay Slots) parameter is used to configure this delay. Set RN=0 (no delays) for small networks with few repeaters or repeaters that are not within range of each other. Set RN=1 for systems with 2 to 5 repeaters that may be within range of each other.

The actual length of the delay is computed by the formula:

Delay (ms) = L * DS

DS = (-41-RSSI)/10*RN)+RandomInt(0,RN)

Where L is the length of the transmitted packet in milliseconds, DS is the number of delay slots to wait, RSSI is the received signal strength in dBm, RN is the value of the RN register and

RandomInt(A,B) is a function that returns a random integer from A to B-0

© 2014 Digi International Inc.

42

XStream™ OEM RF Module – Product Manual v5.x00

Response packet delay

As a packet propagates through the repeater network, if any node receives the data and generates a quick response, the response needs to be delayed so as not to collide with subsequent retransmissions of the original packet. To reduce collisions, both repeater and end node radios in a repeater network will delay transmission of data shifted in the serial port to allow any repeaters within range to complete their retransmissions.

The time for this delay is computed by the formula:

Maximum Delay (ms) = L * DS

DS = ((-41-(-100))/10)*RN)+RN+1

Where L is the length of the transmitted packet in milliseconds, DS is the number of delay slots to wait, RSSI is the received signal strength in dBm, and RN is the value of the RN register.

Use Case - Broadcast Repeater Network

Consider modules R1 through R10 each communicating to a PLC using the ModBus protocol and spaced evenly in a line. All ten nodes are configured as “destinations and repeaters” within the scope of Basic Broadcast Communications (MD=3, AM, DT=0xFFFF, PK=0x100, RO=0x03,

RB=0x100, RN=1). The Base Host (BH) shifts payload that is destined for R10 to R1. R1 initializes RF communication and transmits payload to nodes R2 through R5 which are all within range of R1. Modules R2 through R5 receive the RF packet and retransmit the packet simultaneously. They also send the data out the serial ports, to the PLC's.

Table 403. Commands used to configure repeater functions

AT

Command

AM

DT

MD

MY

RN

WR

Binary

Command

0x3A (58d)

0x00 (0d)

0x3C (60d)

0x2A (42d)

0x19 (25d)

0x08 (8d)

AT Command Name

Auto-set MY

Destination Address

RF Mode

Source Address

Delay Slots

Write

Range

-

0 – 0xFFFF

3 - 4

0 – 0xFFFF

0 – 0xFF (slots)

-

# Bytes

Returned

1

2

-

2

1

-

Factory

Default

0

-

-

0

0

0xFFFF

Bandwidth Considerations

Using broadcast repeaters in a network reduces the overall network data throughput as each repeater must buffer an entire packet before retransmitting it. For example: if the destination is within range of the transmitter and the packet is 32 bytes long, the transmission will take 72ms on a 9600 baud XStream Module (much faster modules are available). If that same packet has to propagate through two repeaters, it will take 72ms to arrive at the first repeater, another 72 ms to get to the second and a final 72ms to get to the destination for a total of 216ms. Taking into account UART transfer times (~1ms/byte at 9600 baud), a server to send a 32 byte query and receive a 32 byte response is ~200ms, allowing for 5 polls per second. With the two repeaters in the path, the same query/response sequence would take about 500ms for 2 polls per second.

To summarize, this system is sending and receiving 64 bytes 5 times per second for a throughput of 320 bytes per second with no repeaters and 128 bytes per second with 2 repeaters. Generally, the network throughput will decrease by a factor of 1/(R+1), with R representing the number of repeaters between the source and destination.

Note that these numbers are absolutely worst case to illustrate how the system would perform in a typical, low bandwidth system. As a counter example the 115kbps 9XTend radio can transfer the same 32 byte packet in 12 ms for a round trip with UART transfer times of ~30ms or 33 polls per second (1066 bytes per second) with no repeaters. With two repeaters the time would be

~100ms round trip time for 10 polls per second or 320 bytes per second network throughput with two repeaters.

© 2014 Digi International Inc.

43

XStream™ OEM RF Module – Product Manual v5.x00

4.3. Acknowledged Communications

4.3.1. Acknowledged Mode

Characteristics: Reliable delivery through positive acknowledgements for each packet

Throughput, latency and jitter vary depending on the quality of the channel and the strength of the signal.

Recommended Use: Acknowledge Mode configuration is appropriate when reliable delivery is required between modules. If messages are smaller than 256 bytes, use RB and RO commands to align RF packets with application packets.

Required Parameter Values (TX Module): RR (Retries) >= 1

Related Commands: Networking (DT, MK, RR), Serial Interfacing (PK, RN, TT, RO, RB)

Table 404. Sample Network Profile

Module

All

Parameter Settings (assume default values for parameters not listed)

ATRR A (set number of Retries to 0x0A)

ATRN 5 (set number of Delay Slots to 5)

Acknowledged Mode Connection Sequence

Figure 406. Acknowledged Mode State Diagram

After sending a packet while in Acknowledged

Mode, the transmitting module listens for an ACK

(acknowledgement). If it receives the ACK, it will either send a subsequent packet (if more transmit data is pending), or will wait for exactly RN random delay slots before allowing another transmission (if no more data is pending for transmission).

© 2014 Digi International Inc.

44

XStream™ OEM RF Module – Product Manual v5.x00

If the transmitting module does not receive the ACK within the allotted time, it will retransmit the packet with a new RF initializer following the ACK slot. There is no delay between the first ACK slot and the first retransmission. Subsequent retransmissions incur a delay of a random number of delay slots, between 0 and RN. If RN is set to 0 on the transmitting module, there are never any back-off delays between retransmissions. Note that during back-off delays, the transmitting module will go into Idle Mode and may receive RF data. This can have the effect of increasing the back-off delay, as the radio cannot return to RF transmit (or retransmit) mode as long as it is receiving RF data.

After receiving and acknowledging a packet, the receiving module will move to the next frequency and listen for either a retransmission or new data for a specific period of time. Even if the transmitting module has indicated that it has no more pending transmit data, it may have not received the previous ACK, and so it may retransmit the packet (potentially with no delay after the ACK slot). In this case, the receiving module will always detect the immediate retransmission, which will hold off the communications channel and thereby reduce collisions. Receiving modules acknowledge each retransmission they receive, but they only pass the first copy of a packet they receive out the UART.

RB and RO parameters are not applied to subsequent packets. This means that once transmission has begun, it will continue uninterrupted until the DI buffer is empty or the streaming limit (TT) has been reached. As with the first packet, the payload of each subsequent packet includes up to the maximum packet size (PK parameter). The transmitting module checks for more pending data near the end of each packet.

The streaming limit (TT parameter) specifies the maximum number of bytes that the transmitting module will send in one transmission event, which may consist of many packets and retries. If the TT parameter is reached, the transmitting module will force a random delay of 1 to RN delay slots (exactly 1 delay slot if RN is zero). Each packet is counted only once toward TT, no matter how many times the packet is retransmitted.

Subsequent packets in acknowledged mode are similar to those in streaming mode, with the addition of an acknowledgement between each packet, and the possibility of retransmissions.

Subsequent packets are sent without an RF initializer, as the receiving modules are already synchronized to the transmitting module from the preceding packet(s) and they remain synchronized for the duration of the transmission event. Each retransmission of a packet includes an RF initializer.

Once the transmitting module has sent all pending data or has reached the TT limit, the acknowledged transmission event is completed. The transmitting module will not transmit again for exactly RN delay slots, if the local RN parameter is set to a nonzero value. The receiving module will not transmit for a random number of delay slots between 0 and (RN-1), if the local

RN parameter is set to a nonzero value. These delays are intended to lessen congestion following long bursts of packets from a single transmitting module, during which several receiving modules may have themselves become ready to transmit.

© 2014 Digi International Inc.

45

XStream™ OEM RF Module – Product Manual v5.x00

4.3.2. Multi-Streaming Mode

Characteristics: Enables exclusive connections (refer to “Operation” section for definition) Supports the passing of large data streams (> 256 bytes) from multiple remote modules to a base module (If a complete data stream from a remote module is less than 256 bytes, data can be sent from several remotes to a base location without enabling this mode and latencies will be much less.)

Transmissions never acknowledged (ACK) by receiving module(s)

Required Parameter Values (TX Module): MD = 1 (Base), MD = 2 (Remote), RN > 0, RR

> 0, MY ≠ 0xFFFF

Recommended Use: Use this mode in point-to-multipoint networks where remote modules initiate communications and require exclusive (uninterrupted) connections to the base module.

Table 405. Sample Network Profile

Module

Base

Remotes

Parameter Settings (assume default values for parameters not listed)

ATMD 1 (configure module as Multi-Stream Base) *

ATMD 2 (configure module as Multi-Stream Remote) *

* When Multi‐Streaming is enabled, the following parameters are consequently modified (if they have not already been modified from their default states): RR, RN, MY, CD, AT and BT. (refer to Table 4‐

06)

Theory of Operation

When in Multi-Streaming Mode, all remote modules can initiate communications with the base module at the same time, but only one remote is granted an exclusive connection.

After an exclusive connection begins, data is transferred exclusively between two modules without interruption from any other modules in the network.

An exclusive connection is a bi-directional connection that can only be established when in

Multi- Streaming Mode. An exclusive connection is immune to other remote modules interrupting the connection and interleaving data (The interleaved data potentially renders the base module unable to discern from which remote module the data was transmitted).

When an exclusive connection is granted to a single remote, the other remotes are notified that the connection exists. The notification causes the remote modules to postpone transmissions until the base module sends notification that the exclusive connection has ended.

Figure 407. Sample Connection Sequence Diagram

CRP = Connection Request Packet

CGP = Connection Grant Packet

DRP = Disconnect Request Packet (not shown in diagram – applicable when remote connection is disconnected using the pin sleep I/O line.

DGP = Disconnect Grant Packet

ACK = Acknowledgement of reception.

Base module = The central transmitting/receiving module in a network of modules that maintains communications with remote modules.

Remote module = A module in a network that sends data to and receives data from a base module.

Payload = Data contained inside the RF

Data of the RF Packet that originates from a host to be transmitted over‐the‐air.

© 2014 Digi International Inc.

46

XStream™ OEM RF Module – Product Manual v5.x00

In the connection sequence above, an exclusive connection is first granted to “Remote m”.

The CGP (Connection Grant Packet) is broadcast to all remote modules in the network to communicate the base in engaged in an exclusive connection. Upon receipt of the CGP notification, remote modules will wait for a DGP (Disconnect Grant Packet) before attempting again to send data to the base module.

Initiating a Connection

Connection Guidelines:

A remote module can only request a connection with the base module.

The base module may hold off or grant a connection request to another module.

A remote module will not try to establish a connection if one already exists.

A connection fails if no response is received after RR (Retries) CRP packets. After a failure, whatever condition was causing a connection to be established is cleared. If the condition was data to be sent, all data in the DI buffer will be flushed. If the condition was DI3 transition, then no connection will be attempted until another correct DI3 transition.

A global connection cannot fail. (Definition is on next page.)

Once in Multi-Streaming Mode (MD > 0), several events can initiate an exclusive connection:

Remote module has payload to transmit. After a remote module receives data from its host, the module will attempt to establish a connection with the base module. The connection is defined by the remote’s DT (Destination Address) parameter. If another remote has a connection with the base, no connection will be established until the connection runs its course. Any remotes requesting a connection will then arbitrate for the next connection. RR

(Retries) and RN (Random back-off) parameters control this arbitration.

Base sets the DT (Destination Address) parameter. When the base module sets the DT

(Destination Address) parameter, an exclusive connection is immediately initiated with the remote module that has a matching DT parameter. After the DT command is sent (If

ATCM=1), the base module indicates a successful connection with a “CONNECT XXXX” string where "XXXX" is the remote's address. An unsuccessful connection is indicated with an

“ERROR” string. If the connection is successful, the module immediately exits AT Command

Mode and data can be sent to and received from the connected remote module. If an error is returned, the module stays in AT Command Mode. If a base is connected to a remote when the DT command is executed, the current connection is disconnected before a new connection is created.

DI3 pin (pin 2, SLEEP) is asserted (set low). Both base and remote modules can create a connection (defined by the current DT (Destination Address) parameter) when the DI3 pin is asserted (driven high). DR (DI3 Configuration) Command is used to establish this mode. If a remote asserts DI3, a connection request will be sent when no connection is active. If the base asserts DI3, a connection will immediately be established with the remote after any connection.

© 2014 Digi International Inc.

47

XStream™ OEM RF Module – Product Manual v5.x00

Initiating a Disconnection

To disconnect, the base module sends a DGP (disconnect grant packet). A remote module can only request a disconnect. The following conditions cause a disconnect:

No over-the-air data sent or received for CE (Connection Inactivity Timeout) time. If no overthe-air data is successfully sent (no acknowledgement received) or received (any good packet) for CE time, the connection will be dropped. Only a base module can detect this condition. Refer to CE Command.

Absolute CB (Connection Duration Timeout). The CB parameter defines an absolute timeout.

A timer is started on the remote units when a connection is established. When the connection has been active for CB time, the base will close the connection. A remote that detects this condition will automatically disconnect (it will not send a DRP (disconnect request packet)). Remotes that monitor a connection between the base and another remote will disregard any connection after the CB time. Refer to CB Command.

DI3 pin (pin 2, SLEEP) is de-asserted (set high). A base or remote module can cause a disconnect by setting the DI3 line high. If no connection is active, the de-assertion is ignored. A remote will request a disconnect if DI3 is de-asserted and the remote is currently connected the base. Refer to DR (DI3 Configuration) Command.

A remote or a base module receives the ATDC (Disconnect) Command.

Configuration

AT Command Mode

AT command mode is used for all commands on base and remote modules. Binary command mode is not available when MD = 1 or 2.

The base is in AT command mode when not engaged in an exclusive connection with a remote.

No AT Command Mode sequence is needed. When a base module is connected to a remote module, the AT Command Mode sequence is used to enter AT command mode. The connection with the remote is maintained. Care should be taken that the CE (Connection Inactivity) timeout does not occur while in AT Command Mode.

The remote must use the AT command sequence to enter AT Command Mode. When a connection exists with a base module, the connection is maintained. Care must be taken that the

CB (Connection Duration) timeout does not occur while in AT Command Mode.

As of firmware version, 4.30, a faster method is available for entering AT Command Mode. If the

BT and AT parameters are set to 0, BT (Guard Time Before) and AT (Guard Time After) times are set to 6 milliseconds.

Beware that this will also mean that AT Command Mode cannot be entered by manually typing the AT command sequence (usually “+++”), because the AT time will occur faster than the characters can be typed.

Auto Configuration

When enabling Multi-Streaming Modes (by setting the MD (RF Mode) parameter to 1 or 2), other parameter values are automatically modified to support the mode. For example, when the MD parameter is changed to 1 or 2, the RR parameter is changed to 0x0A (hex). The modification only occurs if the RR parameter is 0 (its default) before the MD command was executed. If any other value is found for the RR parameter, the RR parameter will not be changed. Auto configuration occurs every time the module is powered-up.

© 2014 Digi International Inc.

48

XStream™ OEM RF Module – Product Manual v5.x00

Table 406. Auto Configurations

Parameter changed

when MD = 1 or 2

RR (Retries)

RN (Delay Slots)

MY (Source Address)

CD (DO3 Configuration)

BT (Guard Time Before)

AT (Guard Time After)

Condition for modification

to take place (default values)

If RR = 0

If RN = 0

If MY = 0xFFFF (and MD = 2)

If CD = 0

If BT = 0x0A

If AT = 0x0A

Resulting Parameter Value

RR = 0x0A (10 decimal)

RN = 5

Unique value based on serial number *

CD = 3

BT = 0

AT = 0

* The system requires that each remote have a unique address. The automatic address is based on the serial number and is not guaranteed unique, although the chances for a duplicate address are 1 in 16,000. No method currently exists for detecting and reassigning duplicate remote addresses.

Global Connection

The base module can connect to all remote modules (to send a broadcast message) by connecting with a DT address of 0xFFFF (hex). There will be no acknowledgements from the remote radios and each packet from the base will be sent RR times. A remote cannot send messages to a base during a global connect.

The CGP and DGP packets will be sent RR times to begin and end the global connection respectively. The connection can be terminated by CE, CB timers, DI3 or ATDC Command as any other connections.

Sleep Modes and Connections

Cyclic sleep can be used with the remote modules to conserve power. ST “Time before Sleep”

Parameter defines how long after a disconnect a remote will stay awake. A module is not allowed to enter sleep mode when it is engaged in a connection. A module will wake as defined by SM parameter and check for an RF message. If a message is detected, the module will stay awake only if the message is a connect message from the base for this module. DI3 (pin 2) wake-up can be used to wake a remote module. Usually the connection on DI3 should also be enabled so that a connection is established on wake-up.

Note: The ST (Time Before Sleep) time must be set long enough to account for the time it could take to make a connection if several remote modules get a connection before a remote’s ST times out.

Pin sleep can also be used with a remote module. A module will not be allowed into pin sleep while a connection is active. Usually the connection on DI3 (DR = 4) should also be enabled so that a connection is established on wakeup. Pin wake-up could also be used to scan for a connection at an interval not defined by the cyclic sleep modes.

I/O Passing and Connections

I/O lines can be passed between a remote and base module by enabling I/O line passing (see the

RT, DR, CD, CO, CS, BK, BO commands). When a connection is not active, the output lines on the base and remote modules will be in their default state. When a connection is established, the base and remote output line will be set to reflect the corresponding input lines.

Monitoring Connections

The DO3 pin (RX LED) can be used to show when a connection is active on both remote and base modules. This is the default condition. This line will be asserted (high) during a connection and de-asserted (low) when there is no connection.

A base module can also be set to send the “CONNECT XXXX” string (where “XXXX” is the connecting module’s MY (Source Address) parameter) anytime a connection is established. Refer to CM (Connection Message) Command.

© 2014 Digi International Inc.

49

XStream™ OEM RF Module – Product Manual v5.x00

Appendix A: Agency Certifications

FCC Certification

The XStream OEM RF Module complies with Part 15 of the FCC rules and regulations. Compliance with the labeling requirements, FCC notices and antenna usage guidelines is required.

To fulfill the FCC Certification requirements, the OEM must comply with the following FCC regulations:

The system integrator must ensure that the text on the external label provided with this device is placed on the outside of the final product (Figure A.1 for 900 MHz operations or

Figure A.2 for 2.4 GHz operations).

The XStream OEM RF Module may be used only with Approved Antennas that have been tested with this module. (Table A-01 or Table A-02)

FCC Notices:

IMPORTANT: The 9XStream (900 MHz) and 24XStream (2.4 GHz) OEM Modules have been certified by the FCC for use with other products without any further certification (as per FCC section 2.1091).

Changes or modifications not expressly approved by Digi could void the user’s authority to operate the equipment.

IMPORTANT: OEMs must test their final product to comply with unintentional radiators (FCC section

15.107 and 15.109) before declaring compliance of their final product to Part 15 of the FCC Rules.

IMPORTANT: The XStream OEM RF Modules have been certified for remote and base radio applications. If the XStream will be used for portable applications, the device must undergo SAR testing.

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

Re-orient or relocate the receiving antenna.

Increase the separation between the equipment and receiver.

Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

Consult the dealer or an experienced radio/TV technician for help.

© 2014 Digi International Inc.

50

XStream™ OEM RF Module – Product Manual v5.x00

OEM Labeling Requirements

Label Warning

WARNING: The Original Equipment Manufacturer (OEM) must ensure that FCC labeling requirements are met. This includes a clearly visible label on the outside of the final product enclosure that displays the contents shown in the figure below.

Figure A01. Required FCC Label for OEM products containing 9XStream (900 MHz) OEM RF Module

Contains FCC ID: OUR9XSTREAM

The enclosed device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference and (2) this device must accept any interference received, including interference that may cause undesired operation.

Figure A02. Required FCC Label for OEM products containing 24XStream (2.4 GHz) OEM RF Module

Contains FCC ID: OUR-24XSTREAM

The enclosed device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference and (2) this device must accept any interference received, including interference that may cause undesired operation.

Antenna Usage

Antenna Warning

WARNING: This device has been tested with Reverse Polarity SMA connectors with the antennas listed in Tables A.1 and A.2 of Appendix A. When integrated in OEM products, fixed antennas require installation preventing end-users from replacing them with nonapproved antennas. Antennas not listed in the tables must be tested to comply with

FCC Section 15.203 (unique antenna connectors) and Section 15.247 (emissions).

RF Exposure

WARNING: This equipment is approved only for mobile and base station transmitting devices, separation distances of (i) 20 centimeters or more for antennas with gains < 6 dBi or

(ii) 2 meters or more for antennas with gains ≥ 6 dBi should be maintained between the antenna of this device and nearby persons during operation. To ensure compliance, operation at distances closer than this is not recommended.

The preceding statement must be included as a CAUTION statement in manuals for OEM products to alert users on FCC RF Exposure compliance.

Digi Modules are pre-FCC approved for use in fixed base station and mobile applications. As long as the antenna is mounted at least 20 cm (8 in) from nearby persons, the application is considered a mobile application. If the antenna will be mounted closer than 20 cm to nearby persons, then the application is considered “portable” and requires an additional test performed on the final product. This test is called the Specific Absorption Rate (SAR) testing and measures the emissions from the module and how they affect the person.

Over 100 additional antennas have been tested and are approved for use with Digi 900

MHz Modules (including “Mag Mount”, “Dome”, “Multi-path” and “Panel” antennas). Because of the large number of approved antennas, Digi requests that you send specific information about an antenna you would like to use with the module and Digi will evaluate whether the antenna is covered under the FCC certification.

© 2014 Digi International Inc.

51

XStream™ OEM RF Module – Product Manual v5.x00

FCC-Approved Antennas

Manufacturer

Digi

Digi

Digi

Digi

Digi

Digi

Digi

Digi

Digi

*

*

*

*

*

*

*

Table A01. Antennas approved for use with 9XStream (900 MHz) OEM RF Modules.

Part Number

*

*

A09-Y8

*

*

A09-Y11 (FCC pending)

A09-F2

A09-F5

A09-F8

*

*

A09-M7

A09-H

A09-HBMM-P5I

A09-QBMM-P5I

*

Type

Yagi

Yagi

Yagi

Yagi

Yagi

Yagi

Omni Direct.

Omni Direct.

Omni Direct.

Omni Direct.

Omni Direct.

Omni Direct.

1/2 wave antenna

1/2 wave antenna

1/4 wave antenna

1/4 wave integrated wire antenna

Gain

6.2 dBi

7.2 dBi

8.2 dBi

9.2 dBi

10.2 dBi

11.2 dBi

2.2 dBi

5.2 dBi

8.2 dBi

9.2 dBi

7.2 dBi

7.2 dBi

2.1 dBi

2.1 dBi

1.9 dBi

1.9 dBi

Application

Fixed/Mobile **

Fixed/Mobile **

Fixed/Mobile **

Fixed/Mobile **

Fixed/Mobile **

Fixed/Mobile **

Fixed **

Fixed **

Fixed **

Fixed **

Fixed **

Fixed **

Fixed/Mobile **

Fixed/Mobile **

Fixed/Mobile **

Fixed/Mobile **

Manufacturer

Digi

Digi

Digi

Digi

Digi

Digi

Digi

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

Table A02. Antennas approved for use with 24XStream (2.4 GHz) OEM RF Modules.

Part Number

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

A24-P8

A24-P13

*

*

*

A24-P19

A24-HABMM-P6I

A24-HBMM-P6I

A24-HABSM

A24-QABMM-P6I

A24-Q1

*

Type

Yagi

Yagi

Yagi

Yagi

Yagi

Yagi

Yagi

Yagi

Yagi

Omni Direct

Omni Direct

Omni Direct

Omni Direct

Omni Direct

Omni Direct

Omni Direct

Omni Direct

Omni Direct

Panel

Panel

Panel

Panel

Panel

Panel

Dipole

Dipole

Dipole

Monopole

Monopole

Monopole

Gain

6 dBi

8.8 dBi

9 dBi

10 dBi

11 dBi

12 dBi

12.5 dBi

13.5 dBi

15 dBi

2.1 dBi

3 dBi

13 dBi

14 dBi

15 dBi

16 dBi

19 dBi

2.1 dBi

2.1 dBi

2.1 dBi

5 dBi

7.2 dBi

8 dBi

9.5 dBi

10 dBi

12 dBi

15 dBi

8.5 dBi

1.9 dBi

1.9 dBi

1.9 dBi

Application

Fixed **

Fixed **

Fixed **

Fixed **

Fixed **

Fixed **

Fixed **

Fixed **

Fixed **

Fixed/Mobile **

Fixed/Mobile **

Fixed/Mobile **

Fixed **

Fixed **

Fixed **

Fixed **

Fixed **

Fixed **

Fixed **

Fixed **

Fixed **

Fixed **

Fixed **

Fixed **

Fixed/Mobile **

Fixed/Mobile **

Fixed/Mobile **

Fixed/Mobile **

Fixed/Mobile **

Fixed/Mobile **

* FCC‐approved antennas not inventoried by Digi – Contact Digi (866) 765‐9885 for information.

** Can be approved for portable applications if integrator gains approval through SAR testing

© 2014 Digi International Inc.

Min. Separation Distance

20 cm

20 cm

20 cm

20 cm

20 cm

1 cm

1 cm

20 cm

20 cm

20 cm

20 cm

20 cm

20 cm

20 cm

20 cm

1 cm

Min. Separation Distance

2 m

2 m

2 m

2 m

2 m

2 m

2 m

2 m

2 m

20 cm

20 cm

2 m

2 m

2 m

2 m

2 m

20 cm

20 cm

20 cm

20 cm

2 m

2 m

2 m

2 m

2 m

2 m

2 m

20 cm

20 cm

20cm

52

XStream™ OEM RF Module – Product Manual v5.x00

IC (Industry Canada) Certification

Labeling requirements for Industry Canada are similar to those of the FCC. A clearly visible label on the outside of the final product enclosure must display the following text:

Contains Model 9XStream Radio (900 MHz), IC: 4214A-9XSTREAM

Contains Model 24XStream Radio (2.4 GHz), IC: 4214A 12008

Integrator is responsible for its product to comply with IC ICES-003 and FCC Part 15, SuB-0 B

- Unintentional Radiators. ICES-003 is the same as FCC Part 15 SuB-0 B and Industry Canada accepts FCC test report or CISPR 22 test report for compliance with ICES-003.

© 2014 Digi International Inc.

53

XStream™ OEM RF Module – Product Manual v5.x00

Appendix B: Development Guide

XStream OEM Development Kit Contents

The Development Kit includes all the hardware and software needed for a robust wireless link:

Table B01. XStream Development Kit Contents

Item

Quick Start Guide

CD

XStream OEM RF Module 1

XStream OEM RF Module 1

1

1

Digi Interface Board

Antenna

2

1

Serial Loopback Adapter 1

NULL Modem Adapter

(male-to-male)

Qty. Description

1

1

Part Number

Familiarizes users with some of the module’s most important functions. MD0016

Contains documentation, software and tools needed for RF operation. MD0030

Long Range OEM RF Module w/ RPSMA Connector

Long Range OEM RF Module w/ attached wire antenna varies varies

Enables communication to RS-232/485/422 devices

900 MHz RPSMA, 6" Half-Wave, dipole, articulating

Connects to the female RS-232 (DB-9) serial connector of the Digi

Interface Board and can be used to configure the module to function as a repeater (for range testing)

Connects to the female RS-232 (DB-9) serial connector of the Digi

Interface Board and can be used to connect the module to another

DCE (female DB9) device

Used to bypass radios to verify serial cabling is functioning properly

XIB-R

A09-HASM-675

JD2D3-CDL-A

JD2D2-CDN-A

JD3D3-CDN-A

NULL Modem Adapter

(female-to-female)

Male DB-9 to

RJ-45 Adapter

Female DB-9 to

RJ-45 Adapter

Power Adapter

RS-232 Cable (6’)

1

1

2

2

Facilitates adapting the DB-9 Connector of the Digi Interface

Board to a CAT5 cable (male DB9 to female RJ45)

Facilitates adapting the DB-9 Connector of the Digi Interface

Board to a CAT5 cable (female DB9 to female RJ45)

JE1D2-CDA-A

JE1D3-CDA-A

Allows Interface Board to be powered by a 110 Volt AC power supply JP4P2-9V10-6F

Connects interface board to devices having an RS-232 serial port JD2D3-CDS-6F

Interfacing Hardware

Digi developed proprietary interface boards to facilitate the connection between XStream

OEM RF Modules and serial devices. Digi has developed an interface board that supports the RS-

232/485/422 protocols (Digi part number: XIB-R).

© 2014 Digi International Inc.

54

XStream™ OEM RF Module – Product Manual v5.x00

The following section illustrates properties of the Digi XIB-R Interface Board. The Digi Interface board provides means for connecting the XStream Module to any node that has an available RS-

232 or RS-485/422 connection. Since the module requires signals to enter at CMOS voltages, one of the main functions of the interface board is to convert signals between CMOS and RS-232 levels.

© 2014 Digi International Inc.

55

XStream™ OEM RF Module – Product Manual v5.x00

Digi RS-232/485 Interface Board

Figure B01. Front

View

B‐01a.

Power

Switch

B‐01b.

LEDs

B‐01c.

Serial Port

B‐0d.

Power

Connector

B-01a. Power Switch

Move the Power Switch to the on (up) position to power the

Interface Board. DIP Switch (B.2a) settings are only read during a power-up sequence.

B-01b. LEDs

The LED indicators visualize diagnostic status information. The module’s status is represented as follows:

Yellow (top LED) = Serial Data Out (to host)

Green (middle) = Serial Data In (from host)

Red (bottom) = Power/TX Indicator (Red light is on when powered, off briefly during RF transmission)

B-01c. Serial Port

Standard female DB-9 (RS-232) DCE connector – This connector can be also used for RS-485 and RS-422 connections.

B-01d. Power Connector

7-18 VDC Power Connector (Center positive, 5.5/2.1mm) – Power can also be supplied through Pin 9 of the DB-9 Serial Port.

Figure B02. Back View

B‐02a.

DIP Switch

B‐02b.

Config Switch

B-02a. DIP Switch

The DIP Switch automatically configures the XStream OEM RF

Module to operate in different modes. Each time the module assembly (interface board + the RF Module) is powered-on, intelligence on the XIB-R interface board programs the module according to the positions of the DIP Switch. (See figure below for DIP Switch settings)

Note: In cases where AT Commands should not be sent each time the module assembly is powered-on, the processor must be disabled by populating J7 on the interface board.

B-02b. Config (Configuration) Switch

The Configuration Switch provides an alternate way to enter “AT

Command Mode”. To enter “AT Command Mode” at the module’s default baud rate, hold the Configuration Switch down while powering on the module using the Power Switch (B-01a).

Figure B03. Digi XIBR (RS232/485) Interface Board DIP Switch Settings

Refer to table in the

Automatic DIP Switch

Configurations section (next page) for more information regarding configurations triggered by the DIP Switch.

© 2014 Digi International Inc.

56

XStream™ OEM RF Module – Product Manual v5.x00

Automatic DIP Switch Configurations

Each time the module assembly (XStream Module mounted to an XIB-R Interface Board) is powered on, intelligence on the Digi Interface Board sends AT Commands that program the module based on positions of the DIP Switch. Automatic configurations that take place during the power-on sequence affect module parameter values as shown below.

To avoid overwriting previously stored custom configurations (due to the automatic configurations that take place each time the module assembly is powered on), it is necessary to disable a processor located on the XIB-R interface board. To disable the processor, populate J7 of the XIB-R Interface Board. By default, J7 jumper is not populated.

Table B02. Module Powerup Options (J7 jumper and Config Switch)

Condition Behavior

If J7 is populated

If Config Switch is pressed

Processor is disabled and AT Commands are not sent to the Module.

Processor is disabled and Module enters into AT Command Mode.

If J7 is NOT populated and Config Switch is NOT pressed

Execute logic as shown in table below.

Table B03. AT Commands Sent as result of DIP Switch Settings (SW = DIP Switch)

Condition Behavior

Restore Default Parameter Values of the Module

If SW1 and SW2 are ON (up)

AT Commands sent: ATRE (Restore Defaults) Command

ATWR (Write) Command

Serial Interfacing Options

If SW1 is ON (up)

If SW1 is OFF (down)

AT Commands sent: ATCS 0 (RS-232 Operation: CTS function for CTS line,

DB-9 pin 8)

ATCD 2 (DO3 - RX LED = low)

AT Commands sent: ATCS 3 (RS-485 or RS-422 Operation)

ATCD 2 (DO3 - RX LED = low)

Parity Options

If SW5 and SW6 are OFF (down) AT Commands sent: ATNB 0 (parity = none)

If SW5 is OFF (down) and SW6 is ON (up) AT Commands sent: ATNB 1 (parity = even)

If SW5 is ON (up) and SW6 is OFF (down) AT Commands sent: ATNB 2 (parity = odd)

If SW5 is ON (up) and SW6 is ON (up) AT Commands sent: ATNB 5 (parity = 9th bit data over-the-air)

Exit AT Command Mode

Always AT Commands sent: ATCN (Exit AT Command Mode)

© 2014 Digi International Inc.

57

XStream™ OEM RF Module – Product Manual v5.x00

Adapters

The XStream Development Kit comes with several adapters that support the following functions:

Performing Range Tests

Testing Cables

Connecting to other RS-232 DCE and DTE devices

Connecting to terminal blocks or RJ-45 (for RS-485/422 devices)

NULL Modem Adapter (male-to-male)

Part Number: JD2D2-CDN-A (Black, DB-9 M-M) The male-to-male NULL modem adapter is used to connect two DCE devices. A DCE device connects with a straight-through cable to the male serial port of a computer (DTE).

Figure B04. Male NULL modem adapter and pinouts

Figure B05. Example of a module assembly (DCE Device) connecting to another DCE device)

NULL Modem Adapter (female-to-female)

Part Number: JD3D3-CDN-A (Gray, DB-9 F-F) The female-to-female NULL modem adapter is used to verify serial cabling is functioning properly. To test cables, insert the female-to-female

NULL modem adapter in place of a pair of module assemblies (XIB-R-R interface board +

XStream Module) and test the connection without radio modules in the connection.

Figure B06. Female NULL modem adapter and pinouts

Serial Loopback Adapter

For use in RS‐485/422 systems: DB‐9 to RJ‐45 adapters are documented on p45.

Part Number: JD2D3-CDL-A (Red, DB-9 M-F) The serial loopback adapter is used for range testing. During a range test, the serial loopback adapter configures the module assembly to function as a repeater by looping serial data back into the radio for retransmission.

Figure B07. Serial loopback adapter and pinouts

© 2014 Digi International Inc.

58

XStream™ OEM RF Module – Product Manual v5.x00

Antennas

(Refer to Appendix A for a list of FCC-Approved Antennas)

Factors that determine wireless link range:

Ambient RF noise (interference)

Line-of-sight obstructions

Transmit power

Receive sensitivity

Antenna configuration

XStream Antenna Connector Options

To comply with the FCC rules and obtain a “modular” certification, it is required that XStream

Modules utilize a “non standard” connector. This is to ensure the modules are used only with approved antennas. The XStream Modules have two connector options:

RPSMA

MMCX

Alternatively, the XStream Module can be order with an attached wire antenna.

RPSMA

The Reverse Polarity SMA (RPSMA) connector uses the same body as a regular SMA connector. In order to be a “non standard” connector, the gender of the center conductor is changed. The female RPSMA actually has a male center conductor.

MMCX

The Micro-Miniature Connector (MMCX) is a good solution for high volume, price-sensitive applications. The small size and snap on connection make it suitable for attaching an external mounted antenna to a module inside an enclosure.

Antenna Cables

RF cables are typically used to connect a radio installed in a cabinet to an antenna mounted externally. As a general rule, it is best to keep the RF cable as short as possible. All cables promote signal loss which is usually measured in dB loss per 100 ft. Digi provides LMR-

195 rated cables. Common cables and dB losses are included in this table:

Table B04. Potential Signal Strength Loss due to Antenna Cable Length

Cable

Type

Loss at 900 MHz per 100’

(loss per 100m)

Loss at 2.4 GHz per 100’

(loss per 100m)

Diameter

RG-58

RG-174

14.5 dB (47.4 dB)

25.9 dB (85.0 dB)

25.3 dB (83.2 dB)

44.4 dB (145.8 dB)

0.20” (4.95 mm)

0.10” (2.54 mm)

RG-316

LMR-195

LMR-240

24.7 dB (81.0 dB)

11.1 dB (36.5 dB)

7.6 dB (24.8 dB)

42.4 dB (139.0 dB)

19.0 dB (62.4 dB)

12.9 dB (42.4 dB)

0.10” (2.59 mm)

0.20” (4.95 mm)

0.24“ (6.10 mm)

LMR-600 2.5 dB (8.2 dB) 4.4 dB (14.5 dB) 0.59” (15.0 mm)

© 2014 Digi International Inc.

59

XStream™ OEM RF Module – Product Manual v5.x00

Interfacing Protocols

The Module Assembly supports the following interfacing protocols:

RS-232

RS-485 (2-wire) Half-Duplex

RS-485 (4-wire) and RS-422

RS-232 Operation

DIP Switch Settings and Serial Port Connections

Figure B08. Figure B09

RS232 DIP Switch Settings Pins used on the female RS232 (DB9)

Serial Connector

DIP Switch settings are read and applied only while powering‐on.

Table B05. RS232 Signals and their implementations on the XStream Module Assembly

(Low‐asserted signals are distinguished by horizontal line over pin name.)

DB-9 Pin

1

2

5

6

3

4

RS-232 Name

DCD

RXD

TXD

DTR

GND

DSR

AT Command Reference*

DO3

DO

DI

DI3

-

DO3

Description

Data-Carrier-Detect

Received Data

Transmitted Data

Data-Terminal-Ready

Ground Signal

Data-Set-Ready

Implementation

Connected to DSR (pin6)

Serial data exiting the Module Assembly

(to host)

Serial data entering into the Module

Assembly (from host)

Can enable POWER-DOWN on the

Module Assembly

Ground

Connected to DCD (pin1)

7 RTS/CMD DI2 Request-to-Send

Provides RTS flow control or enables

“Command Mode” on the Module

8 CTS DO2 Clear-to-Send Provides CTS flow control

9 DI - Ring Indicator

Optional power input that is connected internally to the positive lead of the front power connector

* The AT Command Reference provides as associative tag when using the AT commands to program the

Module. “DI” stands for Data Input and “DO” for Data Output.

© 2014 Digi International Inc. 60

XStream™ OEM RF Module – Product Manual v5.x00

Wiring Diagram: RS-232 DTE Device to a DCE Module Assembly

Figure B10. RS232 DTE (male connector) device wired to an XStream Module Assembly (female

connector)

Wiring Diagram: DCE Module Assembly to an RS-232 DCE Device

Figure B11. XStream Module Assembly (female connector) wired to an RS232 DTE (male connector)

device

Sample Wireless Connection: DTE DCE --------DCE DCE

Figure B12 Typical wireless connection used for serial communications between DTE and DCE devices

© 2014 Digi International Inc. 61

XStream™ OEM RF Module – Product Manual v5.x00

RS-485 (2-wire) Operation

DIP Switch Settings and Serial Port Connections

Figure B13. Figure B14.

RS485 (2wire) HalfDuplex Pins used on the female RS232 (DB9)

DIP Switch Settings Serial Connector

Figure B15

RS485 (2wire) with Termination (optional)

Termination is the 120 Ω resistor between T+ and T-.

DIP Switch settings are read and applied only while powering-on.

Note: Refer to Figure B-022 and Figure B-023 (p45) for RJ-45 connector pin designations used in

RS-485/422 environments.

Table B06. RS485 (2wire halfduplex) Signals and their implementations on the XStream Module

Assembly

Description DB-9 Pin RS-485 Name

2 T/R- (TRA)

5

8

9

1, 3, 4, 6, 7

GND

T/R+ (TRB)

PWR

Negative Data Line

Ground Signal

Positive Data Line

Power

Implementation

Transmit serial data to and from the

XStream Module Assembly

Ground

Optional power input that is connected internally to the front power connector not used

Transmit serial data to and from the

XStream Module Assembly

Wiring Diagram: RS-485 (2-wire) Half-Duplex

Figure B16. XStream Module Assembly in an RS485 (2wire) halfduplex environment

© 2014 Digi International Inc.

62

XStream™ OEM RF Module – Product Manual v5.x00

RS-485 (4-wire) and RS-422 Operation

DIP Switch Settings and Serial Port Connections

Figure B17 Figure B18

RS485 (4wire) and RS422 Pins used on the female RS232 (DB9)

DIP Switch Settings Serial Connector

Figure B19

RS485 (4wire) and RS422 with Termination (optional)

Termination is the 120 Ω resistor between T+ and T-.

DIP Switch settings are read and applied only while powering-on.

Table B07. RS485/422 (4wire) Signals and their implementations with the Module Assembly

DB-9 Pin

RS-485/422

Name

Description Implementation

2

3

5

T- (TA)

R- (RA)

GND

Transmit Negative

Data Line

Receive Negative

Data Line

Signal Ground

Serial data sent from the XStream Module Assembly

Serial data received by the XStream Module Assembly

Ground

7

8

R+ (RB)

T+ (TB)

Receive Positive

Data Line

Transmit Positive

Data Line

Serial data received by the XStream Module Assembly

Serial data sent from the XStream Module Assembly

9

1, 4, 6

PWR Power

Optional power input that is connected internally to the front power connector not used

Wiring Diagram: RS-485 (4-wire) Half-Duplex

Figure B20. XStream Module Assembly in an RS485 (4wire) environment

© 2014 Digi International Inc.

63

XStream™ OEM RF Module – Product Manual v5.x00

Wiring Diagram: RS-422

Figure B21. XStream Module Assembly in an RS485 (4wire) environment

RS-485/422 Connection Guidelines

The RS-485/422 protocol provides a solution for wired communications that can tolerate high noise and push signals over long cable lengths. RS-485/422 signals can communicate as far as

4000 feet (1200 m). RS-232 signals are suitable for cable distances up to 100 feet (30.5 m).

RS-485 offers multi-drop capability in which up to 32 nodes can be connected. The RS-422 protocol is used for point-to-point communications.

Suggestions for integrating the XStream Module with the RS-485/422 protocol:

When using Ethernet twisted pair cabling: Select wires so that T+ and T- are connected to each wire in a twisted pair. Likewise, select wires so that R+ and R- are connected to a twisted pair. (For example, tie the green and white/green wires to T+ and T-.)

For straight-through Ethernet cable (not cross-over cable) – The following wiring pattern works well: Pin3 to T+, Pin4 to R+, Pin5 to R-, Pin6 to T-

Note that the connecting cable only requires 4 wires (even though there are 8 wires).

When using phone cabling (RJ-11) – Pin2 in the cable maps to Pin3 on opposite end of cable and Pin1 maps to Pin4 respectively.

Figure B22 Male (yellow) DB9 to RJ45 Adapters

Figure B23. Female (green) DB9 to RJ45 Adapters

© 2014 Digi International Inc.

64

XStream™ OEM RF Module – Product Manual v5.x00

XCTU Software

Using the XCTU Software

XCTU is Digi-provided software used to interface with and configure XStream OEM RF

Modules. The software application is organized into the following four tabs:

PC Settings tab - Setup PC serial ports to interface with an XStream Module assembly

Range Test tab – Test XStream Module's range and monitor packets sent and received

Terminal tab – Set and read XStream Module parameters using AT Commands

Modem Configuration tab – Set and read XStream Module parameters

Figure B24 XCTU User Interface (PC Settings, Range Test, Terminal and Modem Configuration tabs)

Install XCTU software

Navigate to: www.digi.com/support. Then select “XCTU” under the product list. Select the appropriate driver to install the XCTU software.

Setup

To use the XCTU software, a module assembly (XStream Module mounted to a Digi XIB- R-R

Interface Board) must be connected to the serial port of a PC. The data rate and parity settings of the serial port (“PC Settings” tab) must match those of the module (BD (Baud Rate) and NB

(Parity) Commands).

Serial Communications Software

A terminal program is built into the XCTU Software. Other terminal programs such as

“HyperTerminal” can also be used. When issuing AT Commands through a terminal program interface, use the following syntax:

Figure B‐25 Syntax for sending AT Commands:

Note: To read a parameter value stored in a register, leave the parameter field blank.

The example above issues DT Command to change destination address of the module to “0x1F”.

To save the new value to the module’s non-volatile (long term) memory, issue WR (Write)

Command after modifying parameters

© 2014 Digi International Inc.

65

XStream™ OEM RF Module – Product Manual v5.x00

Appendix C: Additional Information

1-Year Warranty

XStream OEM RF Modules from Digi International Inc. (the ʺProductʺ) are warranted against defects in materials and workmanship under normal use, for a period of 1‐year from the date of purchase. In the event of a product failure due to materials or workmanship, Digi will repair or replace the defective product. For warranty service, return the defective product to Digi, shipping prepaid, for prompt repair or replacement.

The foregoing sets forth the full extent of Digiʹs warranties regarding the Product. Repair or replacement at Digiʹs option is the exclusive remedy. THIS WARRANTY IS GIVEN IN LIEU OF ALL

OTHER WARRANTIES, EXPRESS OR IMPLIED, AND DIGI SPECIFICALLY DISCLAIMS ALL

WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. IN NO

EVENT SHALL DIGI, ITS SUPPLIERS OR LICENSORS BE LIABLE FOR DAMAGES IN EXCESS OF

THE PURCHASE PRICE OF THE PRODUCT, FOR ANY LOSS OF USE, LOSS OF TIME,

INCONVENIENCE, COMMERCIAL LOSS, LOST PROFITS OR SAVINGS, OR OTHER

INCIDENTAL, SPECIAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE OR

INABILITY TO USE THE PRODUCT, TO THE FULL EXTENT SUCH MAY BE DISCLAIMED BY

LAW. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR

CONSEQUENTIAL DAMAGES. THEREFOR, THE FOREGOING EXCLUSIONS MAY NOT APPLY

IN ALL CASES. This warranty provides specific legal rights. Other rights which vary from state to state may also apply.

Ordering Information

Figure C01 Digi OEM RF Module Part Numbers Key

© 2014 Digi International Inc.

66

XStream™ OEM RF Module – Product Manual v5.x00

Contact Digi

If you need assistance, contact technical support:

Documentation: www.digi.com/support/

Technical Support: Phone

Online

(866) 765-9885 toll-free U.S. and Canada

(801) 765-9885 Worldwide

8:00 am – 5:00 pm (U.S. Mountain Time) www.digi.com/support/eservice

© 2014 Digi International Inc.

67

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals