XStream™ OEM RF Module
Product Manual
v5.x00
For XStream OEM RF Module Part Numbers: X09-001…
X09-009…
X09-019…
X24-009…
X24-019…
Reliable 900 MHz and 2.4 GHz OEM RF Modules by Digi International Inc.
XH9-001…
XH9-009…
XH9-019…
XStream™ OEM RF Module – Product Manual v5.x00
XStream OEM RF Module – Product Manual v5.x00
(Part number 90002209 B)
Revision
B
Date
10/15/14
Description
Minor changes and new part number
© 2014 Digi International Inc. All rights reserved
Digi, Digi International, the Digi logo, and XStream
® are trademarks or registered trademarks of Digi International Inc. in the United States and other countries worldwide. All other trademarks mentioned in this document are the property of their respective owners.
Information in this document is subject to change without notice and does not represent a commitment on the part of
Digi International. Digi provides this document “as is,” without warranty of any kind, expressed or implied, including, but not limited to, the implied warranties of fitness or merchantability for a particular purpose. Digi may make improvements and/or changes in this manual or in the product(s) and/or the program(s) described in this manual at any time.
© 2014 Digi International Inc. ii
XStream™ OEM RF Module – Product Manual v5.x00
Contents
1.
XStream OEM RF Module
1.1.
Features
1.1.1.
Worldwide Acceptance
1.2.
Specifications
1.3.
Mechanical Drawings
1.4.
Pin Signals
1.5.
Electrical Characteristics
1.5.1.
Timing Specifications
2.
RF Module Operation
2.1.
Serial Communications
2.1.1.
UART-Interfaced Data Flow
2.1.2.
Flow Control
2.2.
Modes of Operation
2.2.1.
Idle Mode
2.2.2.
Transmit Mode
2.2.3.
Receive Mode
2.2.4.
Sleep Mode
2.2.5.
Command Mode
3.
RF Module Configuration
3.1.
Hands-on Programming Examples
3.1.1.
AT Command Example
3.1.3.
Binary Command Example
3.2.
Command Reference Table
3.3.
XStream Command Descriptions
4.
RF Communication Modes
4.1.
Addressing
4.1.1.
Address Recognition
4.2.
Basic Communications
4.2.1.
Streaming Mode (Default)
4.2.2.
Repeater Mode
4.3.
Acknowledged Communications
4.3.1.
Acknowledged Mode
4.3.2.
Multi-Streaming Mode
Appendix A: Agency Certifications
FCC Certification
OEM Labeling Requirements
Antenna Usage
FCC-Approved Antennas
© 2014 Digi International Inc.
12
12
14
14
17
10
10
11
12
19
19
19
20
21
22
37
4
8
8
6
6
10
4
5
5
40
44
44
46
38
38
39
39
50
50
51
51
52
IC (Industry Canada) Certification
Appendix B: Development Guide
XStream OEM Development Kit Contents
Interfacing Hardware
Adapters
Antennas
Interfacing Protocols
RS-232 Operation
RS-485 (2-wire) Operation
RS-485 (4-wire) and RS-422 Operation
XCTU Software
Using the XCTU Software
Appendix C: Additional Information
1-Year Warranty
Ordering Information
Contact Digi
iii
53
54
60
60
62
63
65
54
54
58
59
65
66
66
66
67
XStream™ OEM RF Module – Product Manual v5.x00
1. XStream OEM RF Module
The XStream OEM RF Module is a drop-in wireless data solution that transfers a standard asynchronous serial data stream over-the-air between devices. The module was engineered to provide OEMs and integrators with an easy-to-use wireless solution that yields reliable, long range and low cost wireless links.
1.1. Features
Long Range
9XStream (900 MHz) Range:
•
Indoor/Urban: up to 1500’ (450 m)
•
Outdoor line-of-sight: up to 7 miles (11 km) w/ 2.1 dBm dipole antenna
•
Outdoor line-of-sight: up to 20 miles (32 km) w/ high gain antenna
24XStream (2.4 GHz) Range:
•
Indoor/Urban: up to 600’ (180 m)
•
Outdoor line-of-sight: up to 3 miles (5 km) w/ 2.1 dBm dipole antenna
•
Outdoor line-of-sight: up to 10 miles (16 km) w/ high gain antenna
Receiver Sensitivity: -110 dBm (900 MHz),
-105 dBm (2.4 GHz)
Advanced Networking and Security
True peer-to-peer (no “master” required), point- to-point, point-to-multipoint, multidrop
Retries and Acknowledgements
7 hopping channels, each with over 65,000 available network addresses
Easy-to-Use
No configuration required
Advanced configurations supported through standard AT and binary
Commands
5 VDC (± 0.25 V) power supply
Continuous RF data stream up to 19.2 kbps
Portable (small form factor easily designed into a wide range of data radio systems)
Software-selectable serial interfacing rates
MODBUS, CTS, RTS, DTR, DCD (and more) I/O Support
Support for multiple data formats (parity, start and stop bits, etc.)
XII™ Interference Immunity
Power-saving Sleep Modes
FHSS (Frequency Hopping Spread Spectrum)
Fast network synchronization (~ 35 ms)
Streaming, Repeater, Multi-Streaming and
Acknowledged Modes supported
© 2014 Digi International Inc.
4
XStream™ OEM RF Module – Product Manual v5.x00
1.1.1. Worldwide Acceptance
FCC Certified (USA) – Refer to Appendix A for FCC Requirements.
Systems that include XStream Modules automatically inherit Digi Certifications
ISM (Industrial, Scientific and Medical) frequency band
Manufactured under ISO 9001:2000 registered standards
9XStream (900 MHz) OEM RF Modules are approved for use in US, Canada, Australia,
Israel.
1.2. Specifications
Table 1‐01. XStream OEM RF Module Specifications
Specification 9XStream (900 MHz) OEM RF Module 24XStream (2.4 GHz) OEM RF Module
Performance
Indoor/Urban Range
Outdoor line-of-sight Range
Interface Data Rate
Throughput Data Rate
RF Data Rate
Transmit Power Output
Receiver Sensitivity up to 1500’ (450 m)
Up to 7 miles (11 km) w/ dipole antenna
Up to 20 miles (32 km) w/ high-gain antenna
1200 – 57,600 bps
(non-standard baud rates also supported)
9,600 bps
10,000 bps
100 mW (20 dBm)
-110 dBm
19,200 bps
20,000 bps
100 mW (20 dBm)
-107 dBm up to 600’ (180 m)
Up to 3 miles (5 km) w/ dipole antenna
Up to 10 miles (16 km) w/ high-gain antenna
1200 – 57,600 bps
(non-standard baud rates also supported)
9,600 bps
10,000 bps
50 mW (17 dBm)
-105 dBm
19,200 bps
20,000 bps
50 mW (17 dBm)
-102 dBm
Power Requirements
Supply Voltage
Receive Current
Transmit Current
Power Down Current
General
Frequency Range
Spread Spectrum
Network Topology
Channel Capacity
Serial Data Interface
Physical Properties
Module Board Size
Weight
Connector
Operating Temperature
Antenna
Integrated Wire (optional)
Connector (optional)
Impedance
5 VDC (± 0.25 V) regulated
50 mA
140 mA
< 26 µA
5 VDC (± 0.25 V) regulated
80 mA
150 mA
< 26 µA
902-928 MHz 2.4000-2.4835 GHz
Frequency Hopping, Wide band FM modulator
Peer-to-Peer, Point-to-Multipoint, Point-to-Point, Multidrop
7 hop sequences share 25 frequencies
CMOS UART
1.600” x 2.825” x 0.350” (4.06 cm x 7.18 cm x 0.89 cm)
0.8 oz (24 g)
11-pin and 4-pin, 0.1” spaced male Berg-type headers
0 to 70º C (commercial), -40 to 85º C (industrial)
¼ wave monopole, 3” (7.62 cm) length, 1.9 dBi Gain
Reverse-polarity SMA or MMCX
50 ohms unbalanced
Certifications (visit www.digi.com
for complete list)
FCC Part 15.247 OUR9XSTREAM
Industry Canada (IC) 4214A-9XSTREAM
OUR-24XSTREAM
4214A 12008
© 2014 Digi International Inc.
5
XStream™ OEM RF Module – Product Manual v5.x00
1.3. Mechanical Drawings
Figure 1‐01. XStream Module Mechanical Drawings (shown with RPSMA antenna connector option)
1.4. Pin Signals
Figure 1‐02. XStream OEM RF Module Pin Numbers (bottom view, pins protruding)
© 2014 Digi International Inc.
6
XStream™ OEM RF Module – Product Manual v5.x00
Table 1‐02. J1 Pin Signal Descriptions
(Low‐asserted signals distinguished with a horizontal line over signal name.)
Module Pin Signal Name
1
DO2 / /
RS-485 Enable
2
3
4
5
6
7
8
9
10
11
DI3 / SLEEP
DO (data out)
DI (data in)
DI2 / / CMD
DO3 / RX LED
/ PWR
VCC
GND
I/O When Active Function
O* low
(clear-to-send) flow control – When pin is driven low,
UART host is permitted to send serial data to the module.
Refer to the Serial Communications (p9) and CS Command
(p23) sections for more information.
RS-485 Enable – To configure this pin to enable RS-485
(2-wire or 4--wire) communications, refer to the Serial
Communications (p9) and CS Command (p23) sections.
I*
O*
I
I**
I*
O high n/a n/a low low high
By default, DI3 pin is not used. To configure this pin to support
Sleep Modes, refer to the Sleep Mode (p13), SM Command
(p32) and PW Command (p29) sections.
Serial data exiting the module (to the UART host). Refer to the
Serial Communications (p9) section for more information.
Serial data entering the module (from UART host). Refer to the
Serial Communications (p9) section for more information.
(request-to-send) flow control – By default, this pin is not used. To configure this pin to regulate the flow of serial data exiting the module, refer to the Serial Communications (p9) and
RT Command (p31) sections.
CMD –Refer to Binary Commands (p17) and RT Command
(p31) sections to enable binary command programming.
Re-boot module.
Pin is driven high during RF data reception; otherwise, the pin is driven low. Refer to the CD Command (p22) to enable.
O low high
- Pin pulses low during RF transmission.
PWR – Indicates power is on and module is not in Sleep Mode.
I***
I
- low
-
-
Pin can be used as a backup method for entering Command
Mode during power-up. Primary method is with “+++”. Refer to the Command Mode (p16) section for more information.
5 VDC regulated (± 0.25)
Ground
* Module has 10K Ω internal pull‐up resistor
** Module has 10K Ω internal pull‐down resistor
*** Module has 100K Ω internal pull‐up resistor
Note: When integrating the XStream Module with a Host PC Board, all lines that are not used should be left disconnected (floating).
Table 1‐03. J2 Pin Signal Descriptions
Module Pin Signal Name
3
4
1
2 reserved
GND
GND
GND
J2 Pins are used primarily for mechanical stability and may be left disconnected.
© 2014 Digi International Inc.
7
XStream™ OEM RF Module – Product Manual v5.x00
1.5. Electrical Characteristics
Figure 1‐03. System Block Diagram
Basic wireless link between hosts
The data flow sequence is initiated when the first byte of data is received in the DI Buffer of the transmitting module (XStream Module A). As long as XStream Module A is not already receiving
RF data, data in the DI Buffer is packetized, then transmitted over-the-air to XStream Module B-0
1.5.1. Timing Specifications
Figure 1‐04. Timing Specifications (“A” and “B” refer to Figure 1‐03.)
Table 1‐04. AC Characteristics (SY parameter = 0, symbols correspond to Figure 1‐03 and Figure 1‐04.)
Symbol
T
T
T
T
TX
TL
RL
ST
Description
Latency from the time data is transmitted until received
Time that /PWR pin is driven low
Time that RX LED pin is driven high
Channel Initialization Time
19200 baud rate
(32 byte packet)
54.0 ms
8.4 ms
13.6 ms
35.0 ms
19200 timing
(B=number of bytes)
For 0 < B < 64,
T = 41.6 + (0.4 * B) ms
For B > 63,
T = 66.8 ms
For 0 < B < 14,
T = 3.24 + (0.4 * B) ms
For B > 13,
T = 8.48 ms
For 0 < B < 65,
T = 0.79 + (0.408 * B)
For B > 64,
T = 26.9 ms
35.0 ms
9600 baud rate
(32 byte packet)
72.0 ms
16.8 ms
25.6 ms
35.0 ms
9600 timing
(B=number of bytes)
For 0 < B < 40,
T = 46.27 + (0.73 * B) ms
For B >= 39 bytes,
T = 74.80 ms
For 0 < B < 14,
T = 6.50 + (0.8 * B) ms
For B > 13,
T = 16.80 ms
For 0 < B < 37,
T = 1.63 + (0.794 * B)
For B > 36,
T = 30.2 ms
35.0 ms
© 2014 Digi International Inc.
8
XStream™ OEM RF Module – Product Manual v5.x00
Table 1‐05. DC Characteristics (Vcc = 4.75 – 5.25 VDC )
Parameter Condition Symbol
VIL
VIH
VIH2
VOL
VOH
IIL
IIH
IIL2
IIL3
IIH2
Input Low Voltage
Input High Voltage
Input High Voltage
Output Low Voltage
Output High Voltage
Input Leakage
Current I/O Pin
Input Leakage
Current I/O Pin
All input signals
All except pin pin *
IOL = 20 mA,
Vcc = 5V
IOH = -20 mA,
Vcc = 5V
Vcc = 5.5V, pin low
(absolute value)
Vcc = 5.5V, pin high
(absolute value)
, , DO
CONFIG
Min
-0.5
0.6 * Vcc
0.9 * Vcc
4.0
2.0
* Reset pulse must last at least 250 nanoseconds
** VI = the input voltage on the pin
Typical
(Vcc – VI) / 10 **
(Vcc – VI) / 47 **
(Vcc – VI) / 10 **
Max
0.3 * Vcc
Vcc + 0.5
Vcc + 0.5
0.7
0.5
3
3
µA
µA mA mA mA
Units
V
V
V
V
V
© 2014 Digi International Inc.
9
XStream™ OEM RF Module – Product Manual v5.x00
2. RF Module Operation
2.1. Serial Communications
The XStream OEM RF Module interfaces to a host device through a CMOS-level asynchronous serial port. Through its serial port, the module can communicate with any UART voltage compatible device or through a level translator to any RS-232/485/422 device.
2.1.1. UART-Interfaced Data Flow
Devices that have a UART interface can connect directly through the pins of the XStream Module as is shown in the figure below.
Figure 2‐01. System Data Flow Diagram in a UART‐interfaced environment
(Low‐asserted signals distinguished with horizontal line over signal name.)
Serial Data
Data enters the XStream Module through the DI pin (pin 4) as an asynchronous serial signal. The signal should idle high when no data is being transmitted.
The UART performs tasks, such as timing and parity checking, that are needed for data communications. Serial communication consists of two UARTs configured with compatible parameters (baud rate, parity, start bits, stop bits, data bits) to have successful communication.
Each data packet consists of a start bit (low), 8 data bits (least significant bit first) and a stop bit
(high). The following figure illustrates the serial bit pattern of data passing through the module.
Figure 2‐02. UART data packet 0x1F (decimal number “31”) as transmitted through the XStream
Module
Example Data Format is 8‐N‐1 (bits – parity ‐ # of stop bits)
© 2014 Digi International Inc.
10
XStream™ OEM RF Module – Product Manual v5.x00
2.1.2. Flow Control
Figure 2‐03. Internal Data Flow Diagram (The five most commonly‐used pin signals shown.)
DI (Data In) Buffer and Flow Control
When serial data enters the XStream Module through the DI Pin (pin 4), then the data is stored in the DI Buffer until it can be transmitted.
When the RB and RO parameter thresholds are satisfied (refer to Transmit Mode section (p11) and command descriptions for more information), the module attempts to initialize an RF connection. If the module is already receiving RF data, the serial data is stored in the DI Buffer.
The size of the DI Buffer can be determined by issuing the RZ (DI Buffer Size) Command. If the
DI buffer becomes full, hardware or software flow control must be implemented in order to prevent overflow (loss of data between the host and XStream Module).
How to eliminate the need for flow control:
1. Send messages that are smaller than the DI buffer size. The size of the DI buffer varies according to the packet size (PK parameter) and the parity setting (NB parameter) used.
2. Interface at a lower baud rate (BD parameter) than the fixed RF data rate.
Two cases in which the DI Buffer may become full and possibly overflow:
1. If the serial interface data rate is set higher than the RF data rate of the module, the module will receive data from the host faster than it can transmit the data over-the-air.
2. If the module is receiving a continuous stream of RF data or monitoring data on a network, any serial data that arrives on the DI pin is placed in the DI Buffer. The data in the DI buffer will be transmitted over-the-air when the module no longer detects RF data in the network.
Hardware Flow Control ( ). When the DI buffer is 17 bytes away from being full; by default, the module de-asserts (high) to signal to the host device to stop sending data (refer to FT
(Flow Control Threshold) and CS (DO2 Configuration) Commands).
Buffer has 34 bytes of memory available. is re-asserted after the DI
Software Flow Control (XON). XON/XOFF software flow control can be enabled using the FL
(Software Flow Control) Command. This option only works with ASCII data.
DO (Data Out) Buffer and Flow Control
When RF data is received, the data enters the DO buffer and is then sent out the serial port to a host device. Once the DO Buffer reaches capacity, any additional incoming RF data is lost. The size of the DO Buffer can be determined by issuing the RZ (DI Buffer Size) Command, then multiplying the result by 1.5.
Two cases in which the DO Buffer may become full and possibly overflow:
1. If the RF data rate is set higher than the interface data rate of the module, the module will receive data from the transmitting module faster than it can send the data to the host.
2. If the host does not allow the module to transmit data out from the DO buffer because of being held off by hardware or software flow control.
Hardware Flow Control ( ). If be sent out the DO Buffer as long as is enabled for flow control (RT Parameter = 2), data will not
(pin 5) is de-asserted
© 2014 Digi International Inc.
11
XStream™ OEM RF Module – Product Manual v5.x00
Software Flow Control (XOFF). XON/XOFF software flow control can be enabled using the FL
(Software Flow Control) Command. This option only works with ASCII data.
2.2. Modes of Operation
XStream OEM RF Modules operate in five modes.
Figure 2‐04. XStream Modes of Operation
The module can only be in one mode at a time.
2.2.1. Idle Mode
When not receiving or transmitting data, the module is in Idle Mode. The module uses the same amount of power in Idle Mode as it does in Receive Mode.
The module shifts into the other modes of operation under the following conditions:
•
Serial data is received in the DI Buffer (Transmit Mode)
•
Valid RF data is received through the antenna (Receive Mode)
•
Command Mode Sequence is issued (Command Mode)
•
Sleep Mode condition is met (Sleep Mode)
After responding to any of the preceding conditions, the module automatically transitions back into Idle Mode.
2.2.2. Transmit Mode
After the first byte of serial data is received in the DI buffer (from the
UART), the module attempts to shift to Transmit Mode and initiate RF connections with other modules. After transmission is complete, the module returns to Idle Mode.
Note: RF reception must complete before the module is able to enter into Transmit
Mode. RF transmission begins after either of the following criteria is
met:
1. RB bytes have been received in the DI buffer and are pending for RF transmission (refer to
RB (Packetization Threshold) Command, p29).
The RB parameter may be set to any value between 1 and the RF packet size (PK), inclusive.
When RB = 0, the packetization threshold is ignored.
2. At least one character has been received in the DI buffer (pending for RF transmission) and
RO time has been observed on the UART (refer to RO (Packetization Timeout) Command).
The timeout can be disabled by setting RO to zero. In this case, transmission will begin after
RB bytes have been received in the DI buffer.
© 2014 Digi International Inc.
12
XStream™ OEM RF Module – Product Manual v5.x00
After either RB or RO conditions are met, the module then initializes a communications channel. (Channel Initialization is the process of sending an RF initializer that synchronizes receiving modules with the transmitting module. During channel initialization, incoming serial data accumulates in the DI buffer.)
Serial data in the DI buffer is grouped into RF packets (refer to PK (RF Packet Size)); converted to RF data; then transmitted over-the-air until the DI buffer is empty.
RF data, which includes the payload data, follows the RF initializer. The payload includes up to the maximum packet size (PK Command) bytes. As the transmitting module nears the end of the transmission, it inspects the DI buffer to see if more data exists to be transmitted. This could be the case if more than PK bytes were originally pending in the DI buffer or if more bytes arrived from the UART after the transmission began. If more data is pending, the transmitting module assembles a subsequent packet for transmission.
Figure 2‐05. Data Transmission Sequence
RF Data Packet
Figure 2‐06. RF Data Packet
* When streaming multiple RF packets, the RF Initializer is only sent in front of the first packet.
RF Initializer
An RF initializer is sent each time a new connection sequence begins. The RF initializer contains channel information that notifies receiving modules of information such as the hopping pattern used by the transmitting module. The first transmission always sends an RF initializer.
An RF initializer can be of various lengths depending on the amount of time determined to be required to prepare a receiving module. For example, a wake-up initializer is a type of RF initializer used to wake remote modules from Sleep Mode (Refer to the FH, LH, HT and SM
© 2014 Digi International Inc.
13
XStream™ OEM RF Module – Product Manual v5.x00
Commands for more information). The length of the wake-up initializer should be longer than the length of time remote modules are in cyclic sleep.
Header
The header contains network addressing information that filters incoming RF data. The receiving module checks for a matching Hopping Channel (HP parameter), Vendor Identification Number
(ID parameter) and Destination Address (DT parameter). Data that does not pass through all three network filter layers is discarded.
CRC (Cyclic Redundancy Check)
To verify data integrity and provide built-in error checking, a 16-bit CRC (Cyclic Redundancy
Check) is computed for the transmitted data and attached to the end of each RF packet. On the receiving end, the receiving module computes the CRC on all incoming RF data. Received data that has an invalid CRC is discarded. (See Receive Mode section.)
2.2.3. Receive Mode
If the module detects RF data while in Idle Mode, the module transitions into Receive
Mode to receive RF packets. Once a packet is received, the module checks the CRC to ensure that the data was transmitted without error. If the CRC data bits on the incoming packet are invalid, the packet is discarded. If the CRC is valid, the packet proceeds to the DO Buffer.
The module returns to Idle Mode when valid
RF data is no longer detected or after an error is detected in the received RF data.
Figure 2‐07. Data Reception Sequence Æ
* Refer to the Addressing section (p36) of the
RF Communication Modes chapter for more information regarding address recognition.
Note: If serial data exists in the DI buffer while the module is in Receive Mode, the UART data will be transmitted after the module is finished receiving the RF data and has returned to Idle Mode.
2.2.4. Sleep Mode
© 2014 Digi International Inc.
Sleep Modes enable the XStream Module to operate at minimal power consumption when not in use. Three Sleep Mode options are available:
•
Pin Sleep (Host Controlled)
•
Serial Port Sleep (Wake on Serial Port activity)
•
Cyclic Sleep (Wake on RF activity)
For the module to transition into Sleep Mode, the module must have a non-zero SM
(Sleep Mode) Parameter and one of the following must occur:
1. The module is idle (no data transmission or reception) for a user-defined period of time (See
ST (Time before Sleep) Command)
2. DI3 (pin 2) is asserted (only for Pin Sleep option)
14
XStream™ OEM RF Module – Product Manual v5.x00
In Sleep Mode, the module will not transmit or receive data until the module first transitions to Idle Mode. All Sleep Modes are enabled and disabled using SM Command.
Transitions into and out of Sleep Modes are triggered by various mechanisms as shown in the table below.
Table 2‐01. Summary of Sleep Mode Configurations
Sleep Mode
Setting
Pin Sleep
(SM = 1)
Serial Port Sleep
(SM = 2)
Cyclic Sleep
(SM = 3-8)
Transition into
Sleep Mode
Microcontroller can shut down and wake modules by asserting (high) SLEEP (pin 2).
Note: Module will complete transmission / reception before activating Pin Sleep.
Automatic transition to Sleep Mode occurs after a user-defined period of inactivity (no transmitting or receiving of data). The period of activity is defined using the ST
(Time before Sleep) Command.
Automatic transition to Sleep Mode occurs in cycles as defined by the SM (Sleep
Mode) Command.
Note: The cyclic sleep time interval must be shorter than the “Wake-up Initializer Timer”
(set by LH Command).
Transition out of
Sleep Mode
De-assert (low)
SLEEP (pin 2).
When serial byte is received on the DI pin
(pin 4).
After the cyclic sleep time interval elapses.
Note: Module can be forced into Idle Mode if PW (Pin Wake-up)
Command is issued.
Related
Commands
SM
SM, ST
SM, ST, HT,
LH, PW
Typical Power
Consumption
26 µA
1 mA
76 µA when sleeping
For more information about Sleep Modes, refer to the individual commands listed in “Related Commands” column of the table. The SM command is central to all Sleep Mode configurations.
Pin Sleep (SM = 1)
Pin Sleep requires the least amount of power. In order to achieve this state, SLEEP pin must be asserted (high). The module remains in Pin Sleep until the SLEEP pin is de-asserted.
After enabling Pin Sleep Mode, the SLEEP pin controls whether the module is active or in Sleep
Mode. When SLEEP is de-asserted (low), the module is fully operational. When SLEEP is asserted
(high), the module transitions to Sleep Mode and remains in its lowest power-consuming state until the SLEEP pin is de-asserted. SLEEP is only active if the module is setup to operate in this mode; otherwise the pin is ignored.
Once in Pin Sleep Mode, is de-asserted (high), indicating that data should not be sent to the module. The PWR pin is also de-asserted (low) when the module is in Pin Sleep Mode.
Note: The module will complete a transmission or reception before activating Pin Sleep.
Serial Port Sleep (SM = 2)
Serial Port Sleep is a Sleep Mode in which the XStream Module runs in a low power state until serial data is detected on the DI pin.
When Serial Port Sleep is enabled, the module goes into Sleep Mode after a user-defined period of inactivity (no transmitting or receiving of data). This period of time is determined by ST (Time before Sleep) Command. Once a character is received through the DI pin, the module returns to
Idle Mode and is fully operational.
Cyclic Sleep (SM = 3-8)
Cyclic Sleep is the Sleep Mode in which the XStream Module enters into a low-power state and awakens periodically to determine if any transmissions are being sent.
When Cyclic Sleep settings are enabled, the XStream Module goes into Sleep Mode after a user- defined period of inactivity (no transmission or reception on the RF channel). The user-defined period is determined by ST (Time before Sleep) Command.
While the module is in Cyclic Sleep Mode, is de-asserted (high) to indicate that data should not be sent to the module during this time. When the module awakens to listen for data, is asserted and any data received on the DI Pin is transmitted. The PWR pin is also de-asserted
(low) when the module is in Cyclic Sleep Mode.
© 2014 Digi International Inc.
15
XStream™ OEM RF Module – Product Manual v5.x00
The module remains in Sleep Mode for a user-defined period of time ranging from 0.5 seconds to
16 seconds (SM Parameters 3 through 8). After this interval of time, the module returns to Idle
Mode and listens for a valid data packet for 100 ms. If the module does not detect valid data (on any frequency), the module returns to Sleep Mode. If valid data is detected, the module transitions into Receive Mode and receives incoming RF packets. The module then returns to
Sleep Mode after a Period of inactivity that is determined by ST “Time before Sleep” Command.
The module can also be configured to wake from cyclic sleep when SLEEP (pin 2) is de-asserted
(low). To configure a module to operate in this manner, PW (Pin Wake-up) Command must be issued. Once SLEEP is de-asserted, the module is forced into Idle Mode and can begin transmitting or receiving data. It remains active until no data is detected for the period of time specified by the ST Command, at which point it resumes its low-power cyclic state.
Note: The cyclic interval time defined by SM (Sleep Mode) Command must be shorter than the interval time defined by LH (Wake-up Initializer Timer).
For example: If SM=4 (Cyclic 1.0 second sleep), the LH Parameter should equal 0x0B (“1.1” seconds). With these parameters set, there is no risk of the receiving module being asleep for the duration of wake-up initializer transmission. “Cyclic Scanning” explains in further detail the relationship between “Cyclic Sleep” and “Wake-up Initializer Timer”
Cyclic Scanning. Each RF transmission consists of an RF Initializer and payload. The wake-up initializer contains initialization information and all receiving modules must wake during the wake-up initializer portion of data transmission in order to be synchronized with the transmitting module and receive the data.
Figure 2‐08. Correct Configuration (LH > SM)
Length of the wake‐up initializer exceeds the time interval of Cyclic Sleep. The receiver is guaranteed to detect the wake‐up initializer and receive the accompanying payload data.
Figure 2‐09. Incorrect Configuration (LH < SM)
Length of wake‐up initializer is shorter than the time interval of Cyclic Sleep. This configuration is vulnerable to the receiver waking and missing the wake‐up initializer (and therefore also the accompanying payload data).
© 2014 Digi International Inc.
16
XStream™ OEM RF Module – Product Manual v5.x00
2.2.5. Command Mode
To modify or read module parameters, the module must first enter into Command Mode (a state in which incoming characters are interpreted as commands). Two command types are supported:
•
AT Commands
•
Binary Commands
AT Commands
To Enter AT Command Mode:
1. Send the 3-character command sequence “+++” and observe guard times before and after the command characters. (Refer to the “Default AT Command Mode Sequence” below.) The
“Terminal” tab (or other serial communications software) of the XCTU Software can be used to enter the sequence.
(OR)
2. Assert (low) the CONFIG pin and either turn the power going to the module off and back on.
(If using a Digi XIB-R Interface Board, the same result can be achieved by keeping the configuration switch pressed while turning off, then on again the power supplying the module assembly (module assembly = module mounted to an interface board))
Default AT Command Mode Sequence (for transitioning to Command Mode):
•
No characters sent for one second (BT (Guard Time Before) parameter = 0x0A)
•
Input three plus characters (“+++”) within one second (CC (Command Sequence Character)
Command = 0x2B-0)
•
No characters sent for one second (AT (Guard Time After) parameter = 0x0A)
To Send AT Commands:
Send AT commands and parameters using the syntax shown below.
Figure 2‐10. Syntax for sending AT Commands
The preceding example would change the module Destination Address to “0x1F”. For modified parameter values to persist in the module registry, changes must be saved to non-volatile memory using WR (Write) Command. Otherwise, parameters are restored to previously saved values after the module is powered off and then on again.
Note: To read the current value of a module parameter, leave the parameter field blank. For example, the following command will return the current destination address: ATDT<CR>
System Response. When a command is sent to the module, the module will parse and execute the command. Upon successful execution of a command, the module returns an “OK” message. If execution of a command results in an error, the module returns an “ERROR” message.
To Exit AT Command Mode:
1. Send ATCN (Exit Command Mode) Command.
(OR)
2. If no valid AT Commands are received within the time specified by CT (Command Mode
Timeout) Command, the Module automatically returns to Idle Mode.
For an example that illustrates programming the module using AT Commands, refer to the
Module Configuration chapter (p18).
© 2014 Digi International Inc.
17
XStream™ OEM RF Module – Product Manual v5.x00
Binary Commands
Sending and receiving parameter values using binary commands is the fastest way to change operating parameters of the module. Binary commands are used most often to sample signal strength (RS parameter) and/or error counts; or to change module addresses and channels for polling systems when a quick response is necessary. Since the sending and receiving of parameter values takes place through the same serial data path as “live” data (received RF payload), interference between the two types of data can be a concern.
Common questions about using binary commands:
What are the implications of asserting CMD while live data is being sent or received?
After sending serial data, is there a minimum time delay before CMD can be asserted?
Is a time delay required after CMD is de-asserted before payload data can be sent?
How does one discern between live data and data received in response to a command?
The CMD pin (pin 5) must be asserted in order to send binary commands to the module. The
CMD pin can be asserted to recognize binary commands anytime during the transmission or reception of data. The status of the CMD signal is only checked at the end of the stop bit as the byte is shifted into the serial port. The application does not allow control over when data is received, except by waiting for dead time between bursts of communication.
CMD (pin 5) must be asserted in order to send binary commands to an XStream Module. CMD can be asserted to recognize commands anytime during transmission or reception of data. A minimum time delay of 100 µs (after the stop bit of the command byte has been sent) must be observed before pin 5 can be de-asserted. The command executes after all parameters associated with the command have been sent. If all parameters are not received within 0.5 seconds, the module aborts the command and returns to Idle Mode. Note: When parameters are sent, they are always two bytes long with the least significant byte sent first.
Commands can be queried for their current value by sending the command logically ORed with the value 0x80 (hexadecimal) with CMD asserted. When the binary value is sent (with no parameters), the current value of the command parameter is sent back through the DO pin.
Figure 2‐11. Binary Command Write then Read
Signal #4 is CMD (pin 5)
Signal #1 is the DIN (pin 4) signal to the radio
Signal #2 is the DOUT (pin 3) signal from the radio
Signal #3 is (pin 1)
In this graph, a value was written to a register and then read out to verify it. While not in the middle of other received data, note that the signal outlines the data response out of the module.
IMPORTANT: For the XStream Module to recognize a binary command, RT (DI2 Configuration)
Command must be issued. If binary programming is not enabled (RT ≠ 1), the module will not recognize that the CMD pin (Pin 5) is asserted and therefore will not recognize the data as binary commands.
© 2014 Digi International Inc.
18
XStream™ OEM RF Module – Product Manual v5.x00
3. RF Module Configuration
3.1. Hands-on Programming Examples
For information about entering and exiting AT and Binary Command Modes, refer to the
Command Mode section (p16).
3.1.1. AT Command Example
To Send AT Commands (Using the Terminal tab of Digi’s XCTU Software)
Example: Both of the following examples change the module’s destination address to 0x1A0D and save the new address to non-volatile memory.
Method 1 (One line per command)
Send AT Command
+++
ATDT <Enter>
ATDT1A0D <Enter>
ATWR <Enter>
ATCN <Enter>
System Response
OK <CR> (Enter into Command Mode) current Destination Address <CR> (Read)
OK <CR> (Change destination address)
OK <CR> (Write to non-volatile memory)
OK <CR> (Exit Command Mode)
Method 2 (Multiple commands on one line)
Send AT Command
+++
ATDT <Enter>
ATDT1A0D,WR,CN <Enter>
System Response
OK <CR> (Enter into Command Mode) current Destination Address <CR> (Read)
OK <CR> (Execute commands)
Digi’s XCTU Software facilitates module programming. To install, double-click the “setup_X-CTU.exe” file that is located at www.digi.com.
Note: In order to use a host PC and the XCTU Software Terminal tab to send data to the module, PC com port settings must match the baud, parity and stop bit parameters stored in the module.
Use the “PC Settings” tab to configure PC com port settings to match module parameter values.
© 2014 Digi International Inc.
19
XStream™ OEM RF Module – Product Manual v5.x00
3.1.3. Binary Command Example
To Send Binary Commands:
Example: Use binary commands to change the XStream Module’s destination address to 0x1A0D and save the new address to non-volatile memory.
1. RT Command must be set to “1” in AT Command Mode to enable binary programming.
2. Assert CMD (Pin 5 is driven high). (Enter Binary Command Mode)
3. Send Bytes (parameter bytes must be 2 bytes long):
00 (Send DT (Destination Address) Command)
0D (Least significant byte of parameter bytes)
1A (Most significant byte of parameter bytes)
08 (Send WR (Write) Command)
4. De-assert CMD (Pin 5 is driven low) (Exit Binary Command Mode)
Note: (pin 1) is de-asserted high when commands are being executed. Hardware flow control must be disabled as will hold off parameter bytes.
© 2014 Digi International Inc.
20
XStream™ OEM RF Module – Product Manual v5.x00
3.2. Command Reference Table
Table 3‐01. XStream Commands (The module expects numerical values in hexadecimal. “d” denotes decimal equivalent.)
AT
Command
AM v4.30*
AT
BD v4.2B*
IU v4.30*
LH
MD v4.30*
MK
MY v4.30*
NB v4.30*
PC v4.22*
PK v4.30*
PW v4.22*
RB v4.30*
RE
RN v4.22*
RO v4.2A*
RP v4.2A*
RR v4.22*
RS v4.22*
Binary
Command AT Command Name
0x3A (58d) Auto-set MY
0x05 (5d) Guard Time After
0x15 (21d)
0x3B (59d) DI2, DI3 Update Timer
0x0C (12d) Wake-up Initializer Timer
0x32 (50d)
0x12 (18d)
RF Mode
Address Mask
0x2A (42d) Source Address
0x23 (35d) Parity
0x1E (30d) Power-up Mode
0x29 (41d) RF Packet Size
0x1D (29d) Pin Wake-up
0x20 (32d) Packetization Threshold
0x0E (14d) Restore Defaults
0x19 (25d)
0x21 (33d)
0x22 (34d)
0x18 (24d)
0x16 (22d)
Delay Slots
0x1C (28d) RSSI
DI2 Configuration
0x2C (44d) DI Buffer Size
SB v4.2B* 0x36 (54d)
SH v4.27C* 0x25 (37d)
0x26 (38d)
0x01 (1d)
0x02 (2d)
0x17 (23d)
0x31 (49d)
Baud Rate
BK v4.30*
BO v4.30*
BT
CB v4.30*
CC
CD v4.2B*
CE v4.30*
CF v4.30*
0x2E (46d)
0x30 (48d)
0x04 (4d)
0x33 (51d)
0x13 (19d)
0x28 (40d)
CL v4.30*
CM v4.30*
CN
CO v4.30*
0x34 (52d)
0x35 (53d)
0x39 (57d)
0x38 (56d)
0x09 (9d)
0x2F (47d)
CS v4.27D* 0x1F (31d)
CT
Serial Break Passing
Serial Break Timeout
Guard Time Before
Connection Duration Timeout
Command Sequence Character
DO3 Configuration
Connection Inactivity Timeout
Connection Failure Count
Last Connection Address
Connection Message
Exit AT Command Mode
E1
ER
FH
FL
DC v4.30*
DR v4.30*
DT
E0
0x06 (6d)
0x37 (55d)
DO3 Timeout
DO2 Configuration
Command Mode Timeout
Disconnect
0x2D (45d) DI3 Configuration
0x00 (0d) Destination Address
0x0A (10d) Echo Off
0x0B (11d) Echo On
0x0F (15d) Receive Error Count
0x0D (13d) Force Wake-up Initializer
0x07 (7d)
FT v4.27B* 0x24 (36d)
GD
HP
HT
0x10 (16d)
0x11 (17d)
0x03 (3d)
Software Flow Control
Flow Control Threshold
Receive Good Count
Hopping Channel
Time before Wake-up Initializer
ID v4.2B*
RT
RZ v4.30*
SL v4.27C*
SM
ST
SY
TO v4.30*
TR v4.22*
TT v4.22*
VR
WR
0x27 (39d) Modem VID
Packetization Timeout
RSSI PWM Timer
Retries
Stop Bits
Serial Number High
Serial Number Low
Sleep Mode
Time before Sleep
Time before Initialization
DO2 Timeout
0x1B (27d) Transmit Error Count
0x1A (26d) Streaming Limit
0x14 (20d)
0x08 (8d)
Firmware Version
Write
Range
-
0x02 – 0xFFFF (x 100 msec)
Standard baud rates: 0 – 6
(custom rates also supported)
-
0 – 4
0 – 0xFFFF
-
-
0 – 0xFFFF
-
0 – 1
0 – 0xFF (bytes)
0 – 0xFFFF
0 – 6
0 – 0xFFFF (x 100 msec)
User-settable: 0x10 - 0x7FFF
Read-only: 0x8000 – 0xFFFF
0 - 0xFFFF (x 100 msec)
0 – 0xFF (x 100 msec)
0 – 4
0 – 0xFFFF
0 – 0xFFFF
0 – 5
0 – 1
0 - 0x100 (bytes)
0 – 1
0 - 0x100 (bytes)
-
0 – 0xFF (slots)
0 – 0xFFFF (x 200 µsec)
0 - 0x7F (x 100 msec)
0 – 0xFF
0x06 – 0x36 (read-only)
0 - 2
(read-only)
0 - 1
0 – 0xFFFF (read-only)
0 – 0xFFFF (read-only)
0 – 8
0 - 0xFFFF (x 1 sec)
0 – 0xFFFF
0 – 0xFFFF (0 = disabled)
0 x 0xFFFF (read-only)
-
Command Category
Networking and Security
Command Mode Options
Serial Interfacing
0 – 1
0 - 0xFFFF (x 1 second)
Serial Interfacing
Serial Interfacing
0 – 0xFFFF (x 100 msec) Command Mode Options
0x01 – 0xFFFF (x 100 msec) Networking and Security
0x20 – 0x7F
0 – 4
0 – 0xFFFF (x 10 msec)
0 – 0xFFFF
(read-only)
0 – 1
-
0 - 0xFFFF (x 1 second)
0 – 4 Serial Interfacing
0x02 – 0xFFFF (x 100 msec) Command Mode Options
0x10 – 0xFFFF (x 100 msec) Sleep (Low Power)
0 – 0xFF (x 100 msec)
Command Mode Options
Serial Interfacing
Networking and Security
Networking and Security
Diagnostics
Networking and Security
Command Mode Options
Serial Interfacing
Networking and Security
Serial Interfacing
Networking and Security
Command Mode Options
Command Mode Options
Diagnostics
Sleep (Low Power)
Serial Interfacing
Serial Interfacing
Diagnostics
Networking and Security
Sleep (Low Power)
Networking and Security
Serial Interfacing
Sleep (Low Power)
Networking and Security
Networking and Security
Networking and Security
Serial Interfacing
Command Mode Options
Serial Interfacing
Sleep (Low Power)
Serial Interfacing
(Special)
Networking and Security
Serial Interfacing
Diagnostics
Networking and Security
Diagnostics
Serial Interfacing
Diagnostics
Serial Interfacing
Diagnostics
Diagnostics
Sleep (Low Power)
Networking and Security
Serial Interfacing
Diagnostics
Networking and Security
Diagnostics
(Special)
# Bytes
Returned
-
2
2
2
1
2
1
1
2
1
-
2
2
2
2
-
1
1
2
1
-
1
1
2
1
2
2
1
1
2
2
1
2
-
1
1
2
-
2
2
1
2
2
1
1
2
2
1
2
2
2
-
1
1
2
-
2
2
-
* Firmware version in which command and parameter options were first supported.
Note: AT Commands issued without a parameter value will return the currently stored parameter.
© 2014 Digi International Inc.
Factory
Default
-
0
0
-
-
0
0
0xC8 (200d)
-
0 varies
0
0
0xFFFF
-
0x0A (10d) factory-set
RF data rate
0
0
0x0A (10d)
0x28 (4d sec)
0x2B (“+”)
0
0x64 (1d sec)
0
-
0
-
0x03
-
0
-
0
-
-
0
0x64 (100d)
0 (disabled)
0x03
0
0xFFFF
-
-
0
-
0
0
-
0
0
0x01
0x0A (10d)
0x01
0
0xFFFF
0xFFFF
0
0
0x40 (64d)
21
XStream™ OEM RF Module – Product Manual v5.x00
3.3. XStream Command Descriptions
Command descriptions in this section are listed alphabetically. Command categories are designated within “< >” symbols that follow each command title. XStream Modules expect parameter numerical values in hexadecimal (designated by the “0x” prefix).
AM (Auto-set MY) Command
<Networking and Security> AM Command is used to automatically set the MY (Source
AT Command: ATAM
Binary Command: 0x3A (58 decimal)
Minimum firmware version required: 4.40
Address) parameter from the factory-set module serial number. The address is formed with bits 29, 28 and 13-0 of the serial number (in that order).
AT (Guard Time After) Command
AT Command: ATAT
Binary Command: 0x05 (5 decimal)
<Command Mode Options> AT Command is used to set the DI time-of-silence that follows the AT command sequence character (CC Command).
By default, AT Command Mode will activate after one second of silence.
Refer to the AT Commands section (p16) to view the default AT Command Mode Sequence.
(x 100 milliseconds)
Number of bytes returned: 2
Default Parameter Value: 0x0A (10 decimal)
CC (Command Sequence Character)
BD (Interface Data Rate) Command
<Serial Interfacing> BD Command allows the user to adjust the UART interface data rate and thus modify the rate at which serial data is sent to the RF module. The new baud rate does not take effect until the CN command is issued. The
RF data rate is unaffected by the BD parameter.
Most applications will require one of the seven standard baud rates; however, non-standard baud rates are also supported.
Note: If the interface data rate is set to exceed the fixed RF data rate of the module, flow control may need to be implemented as described in the Pin Signals (p6), Flow Control
(p10) and CS (DO2 Configuration) sections.
AT Command: ATBD
Binary Command: 0x15 (21 decimal)
Parameter Range (Standard baud rates): 0 – 6
(Non-standard baud rates): 0x7D – 0xFFFF
Parameter
0
1
2
3
4
5
6
Configuration (bps)
1200
2400
4800
9600
19200
38400
57600
Number of bytes returned: 2
Default Parameter Value: Set to equal module’s
factory-set RF data rate.
Related Commands: CN (Exit Command Mode)
Non-standard Interface Data Rates: When parameter values outside the range of standard interface data rates are sent, the closest rate represented by the number is stored in the BD register. For example, a rate of 19200 bps can be set by sending the following command line
"ATBD4B00". Note: When using Digi’s XCTU Software, non-standard interface data rates can only be set and read using the XCTU “Terminal” tab.
When the BD command is sent with a non-standard interface data rate, the UART will adjust to accommodate the requested interface rate. In most cases, the clock resolution will cause the stored BD parameter to vary from the parameter that was sent (refer to the table below).
Reading the BD command (send "ATBD" command without an associated parameter value) will return the value that was actually stored in the BD register.
Table 3‐02. Parameter Sent vs. Parameter Stored
BD Parameter Sent (HEX)
0
4
7
12C
1C200
Interface Data Rate (bps)
1200
19,200
115,200
300
115,200
BD Parameter Stored (HEX)
0
4
7
12B
1B207
© 2014 Digi International Inc.
22
XStream™ OEM RF Module – Product Manual v5.x00
BK (Serial Break Passing) Command
<Serial Interfacing> Pass a serial break condition on the DI pin to the DO pin of another module.
BO (Serial Break Timeout) Command
<Serial Interfacing> DO pin will return to default after no serial break status information is received during the timeout period.
Use with BK parameter = 1.
AT Command: ATBK
Binary Command: 0x2E (46 decimal)
Parameter Range: 0 – 1
Parameter
0
1
Configuration disable enable
Default Parameter Value: 0
Number of bytes returned: 1
Related Commands: BO (Serial Break Timeout)
Minimum Firmware Version Required: 4.30
AT Command: ATBO
Binary Command: 0x30 (48 decimal)
Parameter Range: 0 – 0xFFFF (x 1 second)
Default Parameter Value: 0
Number of bytes returned: 2
Related Commands: BK (Serial Break Passing)
Minimum Firmware Version Required: 4.30
BT (Guard Time Before) Command
<Command Mode Options> BT Command is used to set the DI pin silence time that must precede the command sequence character (CC
Command) of the AT Command Mode Sequence.
Refer to the AT Commands section (p16) to view the default AT Command Mode sequence.
AT Command: ATBT
Binary Command: 0x04 (4 decimal)
Default Parameter Value: 0x0A (10 decimal)
Number of bytes returned: 2
CB (Connection Duration Timeout) Command
<Networking and Security> Set/Read the maximum amount of time an exclusive connection between a base and remote module in a point-to-multipoint network is sustained. The remote module will disconnect when this timeout expires.
CC (Command Sequence Character) Command
<Command Mode Options> CC Command is used to set the ASCII character to be used between
Guard Times of the AT Command Mode Sequence
(BT+ CC + AT). The AT Command Mode
Sequence activates AT Command Mode (from
Idle Mode).
Refer to the AT Commands section (p16) to view the default AT Command Mode sequence.
AT Command: ATCB
Binary Command: 0x33 (51 decimal)
Default Parameter Value: 0x28 (4d seconds)
Number of bytes returned: 2
Related Commands: CE (Connection Inactivity
Timeout), DC (Disconnect), MD (RF Mode)
Minimum Firmware Version Required: 4.30
AT Command: ATCC
Binary Command: 0x13 (19 decimal)
Parameter Range: 0x20 – 0x7F
Default Parameter Value: 0x2B (ASCII “+” sign)
Number of bytes returned: 1
Related Commands: AT (Guard Time After), BT
(Guard Time Before)
© 2014 Digi International Inc.
23
XStream™ OEM RF Module – Product Manual v5.x00
CD (DO3 Configuration) Command
<Serial Interfacing> CD Command is used to redefine the behavior of the DO3 (Data Output
3)/RX LED line.
CE (Connection Inactivity Timeout) Command
<Networking and Security> Set/Read the duration of inactivity that will cause a break in a connection between modules. The base module will disconnect when no payload has been transferred for the time specified by the CE parameter.
AT Command: ATCD
Binary Command: 0x28 (40 decimal)
Parameter Range: 0 – 4
Parameter
0
1
2
3
Configuration
RX LED
Default high
Default low
(reserved)
4
Assert only when packet addressed to module sent
Default Parameter Value: 0
Number of bytes returned: 1
Minimum Firmware Version Required: 4.2B
AT Command: ATCE
Binary Command: 0x34 (52 decimal)
(x 10 milliseconds)
Default Parameter Value: 0x64 (1d second)
Number of bytes returned: 2
Related Commands: CB ( Connection Duration
Timeout), DC (Disconnect), MD (RF Mode)
Minimum Firmware Version Required: 4.30
CF (Connection Failure Count) Command
<Diagnostics> Set/Read the number of times the base module expired retries attempting to send a
Connection Grant Packet. Set to zero to clear the register.
AT Command: ATCF
Binary Command: 0x35 (53 decimal)
Parameter Range: 0 – 0xFFFF
Default Parameter Value: 0
Number of bytes returned: 2
Minimum Firmware Version Required: 4.30
CL (Last Connection Address) Command
<Diagnostics/Networking and Security> Read the address of the remote module that last connected to the base module. A remote module will return its DT (Destination Address) parameter.
AT Command: ATCL
Binary Command: 0x39 (57 decimal)
Parameter Range: 0 – 0xFFFF (read-only)
Number of bytes returned: 2
Minimum Firmware Version Required: 4.30
CM (Connection Message) Command
<Networking and Security> Select whether base sends connect messages to the host when a connection is established. When enabled, a
“CONNECTXXXX” string is sent to the host of the base module. “XXXX” is the MY (Source Address) of the connected remote module.
AT Command: ATCM
Binary Command: 0x38 (56 decimal)
Parameter Range: 0 – 1
Parameter
0
1
Configuration enable disable
Default Parameter Value: 0
Number of bytes returned: 1
Minimum Firmware Version Required: 4.30
© 2014 Digi International Inc.
24
XStream™ OEM RF Module – Product Manual v5.x00
CN (Exit AT Command Mode) Command
<Command Mode Options> CN Command is used to explicitly exit AT Command Mode.
AT Command: ATCN
Binary Command: 0x09 (9 decimal)
CO (DO3 Timeout) Command
<Serial Interfacing> DO3 (Data Output 3) output will return to default after no DI3 (Data Input 3) status information is received during the timeout period.
Use with CD = 1 or 2, DR = 1.
AT Command: ATCO
Binary Command: 0x2F (47 decimal)
Parameter Range: 0 – 0xFFFF (x 1 second)
Default Parameter Value: 3
Number of bytes returned: 2
Related Commands: CD (DO3 Configuration),
DR (DI3 Configuration)
Minimum Firmware Version Required: 4.30
CS (DO2 Configuration) Command
<Serial Interfacing> CS Command is used to select the behavior of the DO2 (Data Output 2) pin signal. This output can provide RS-232 flow control, control the TX enable signal (for RS-485 or RS-422 operations), or set the default level for the I/O line passing function.
By default, DO2 provides RS-232
Send) flow control.
(Clear-to-
CT (Command Mode Timeout) Command
<Command Mode Options> CT Command is used to set the amount of time of inactivity before AT
Command Mode automatically terminates. After a
CT time of inactivity, the module exits AT
Command Mode and returns to Idle Mode. AT
Command Mode can also be exited manually using the CN (Exit AT Command Mode)
Command.
AT Command: ATCS
Binary Command: 0x1F (31 decimal)
Parameter Range: 0 – 4
Parameter
0
1
2
3
4
Default Parameter Value: 0
Configuration
RS-232 flow control
RS-485 TX enable low high
RS-485 TX enable high low
Number of bytes returned: 1
Related Commands: RT (DI2 Configuration),
TO (DO2 Timeout)
Minimum Firmware Version Required: 4.27D
AT Command: ATCT
Binary Command: 0x06 (6 decimal)
Parameter Range: 2 – 0xFFFF
(x 100 milliseconds)
Number of bytes returned: 2
DC (Disconnect) Command
<Networking and Security> DC Command is used (when in Multi-Streaming Mode (MD = 1 or 2)) to explicitly force the disconnection of an active exclusive connection. If MD = 1, the base module will force the disconnection of an exclusive connection. If MD = 2, the remote module will send a “Disconnect Request Packet” to the base module.
AT Command: ATDC
Binary Command: 0x37 (55 decimal)
Related Commands: CB (Connection Duration
Timeout), CE (Connection Inactivity Timeout),
MD (RF Mode)
Minimum Firmware Version Required: 4.30
© 2014 Digi International Inc.
25
XStream™ OEM RF Module – Product Manual v5.x00
DR (DI3 Configuration) Command
<Serial Interfacing> DR Command is used to configure DI3 (pin 2, SLEEP) for I/O line passing
(use with CD = 1 or 2 and CO) or controlling connection status (use with MD = 1 or 2).
AT Command: ATDR
Binary Command: 0x2D (45 decimal)
Parameter Range: 0 – 4
Parameter
0
1
2
Configuration
Disabled
DI3 I/O passing enabled
Connect on low
3
4
Disconnect on high
Connect and Disconnect
Default Parameter Value: 0
Number of bytes returned: 1
Related Commands: CD (DO3 Configuration),
CO (DO3 Timeout), MD (RF Mode)
Minimum Firmware Version Required: 4.30
DT (Destination Address) Command
<Networking and Security> DT Command is used to set the networking address of an
XStream Module. XStream Modules use three filtration layers: Channels (ATHP), Vendor
Identification Number (ATID) and Destination
Addresses (ATDT). DT Command assigns an address to a module that enables it to communicate only with other modules having the
AT Command: ATDT
Binary Command: 0x00
Parameter Range: 0 – 0xFFFF
Default Parameter Value: 0
Number of bytes returned: 2
Related Commands: HP (Hopping Channel), ID
(Module VID), MK (Address Mask) same addresses. All modules that share the same Destination Address can communicate freely with each other.
Modules in the same network with a different Destination Address (than that of the transmitter) will listen to all transmissions to stay synchronized, but will not send any of the data out their serial ports.
E0 (Echo Off) Command
<Command Mode Options> The E0 command turns off character echo in AT Command Mode.
By default, echo is off.
AT Command: ATE0
Binary Command: 0x0A (10 decimal)
E1 (Echo On) Command
<Command Mode Options> E1 Command turns on the echo in AT Command Mode. Each typed character will be echoed back to the terminal when ATE1 is active. E0 is the default.
AT Command: ATE1
Binary Command: 0x0B (11 decimal)
ER (Receive Error Count) Command
<Diagnostics> Set/Read the receive error count.
The error-count records the number of packets
AT Command: ATER
Binary Command: 0x0F (15 decimal) partially received then aborted on reception error. This value returns to 0 after a reset and is
Parameter Range: 0 – 0xFFFF
Default Parameter Value: 0 not non-volatile (value does not persist in the module’s memory after a power-up sequence).
Number of bytes returned: 2
Once the receive error count reaches its
Related Commands: GD (Receive Good Count) maximum value (up to 0xFFFF), it remains at its maximum count value until the maximum count value is explicitly changed or the module is reset.
© 2014 Digi International Inc.
26
XStream™ OEM RF Module – Product Manual v5.x00
FH (Force Wake-up Initializer) Command
<Sleep (Low Power)> FH Command is used to force a Wake-up Initializer to be sent on the next transmission. WR (Write) Command does not need to be issued with FH Command.
AT Command: ATFH
Binary Command: 0x0D (13 decimal)
Use only with cyclic sleep modes active on remote modules.
FL (Software Flow Control) Command
<Serial Interfacing> FL Command is used to configure of module with software flow control.
Hardware flow control is implemented with the
XStream Module as the DO2 pin ( ), which regulates when serial data can be transferred to the module. FL Command is used to allow software flow control. XON character used is
0x11 (17 decimal). XOFF character used is 0x13
(19 decimal).
AT Command: ATFL
Binary Command: 0x07 (7 decimal)
Parameter Range: 0 – 1
Parameter
0
1
Configuration
Disable software flow control
Enable software flow control
Default Parameter Value: 0
Number of bytes returned: 1
FT (Flow Control Threshold) Command
<Serial Interfacing> Set/Read the flow control threshold. When FT bytes have accumulated in the DI buffer, is de-asserted or the XOFF software flow control character is transmitted.
AT Command: ATFT
Binary Command: 0x24 (36 decimal)
Parameter Range: 0 – 0xFF (bytes)
(Maximum value equals the receiving module
DO buffer size minus 0x11 bytes)
Default Parameter Value: Receiving module DO
Buffer size minus 0x11
Number of bytes returned: 2
Minimum Firmware Version Required: 4.27B
GD (Receive Good Count) Command
<Diagnostics> Set/Read the count of good AT Command: ATGD received RF packets. Parameter value is reset to
Binary Command: 0x10 (16 decimal)
0 after every reset and is not non-volatile (value
Parameter Range: 0 – 0xFFFF does not persist in the module’s memory after a
Default Parameter Value: 0 power-up sequence). Once the “Receive Good
Count” reaches its maximum value (up to
0xFFFF), it remains at its maximum count value
Number of bytes returned: 2
Related Commands: ER (Receive Error Count) until the maximum count value is manually changed or the module is reset.
HP (Hopping Channel) Command
<Networking and Security> HP Command is used to set the module hopping channel number.
A channel is one of three layers of addressing available to the module. In order for modules to
AT Command: ATHP
Binary Command: 0x11 (17 decimal)
Parameter Range: 0 – 6 communicate with each other, the modules must have the same channel number since each network uses a different hopping sequence.
Different channels can be used to prevent
Default Parameter Value: 0
Number of bytes returned: 1
Related Commands: DT (Destination Address),
ID (Module VID), MK (Address Mask) modules in one network from listening to transmissions of another.
© 2014 Digi International Inc.
27
XStream™ OEM RF Module – Product Manual v5.x00
HT (Time before Wake-up Initializer) Command
<Sleep (Low Power)> If any modules within range are running in a “Cyclic Sleep” setting, a wake-up initializer must be used by the transmitting module for sleeping modules to remain awake (refer to the LH (“Wake-up
Initializer Timer”) Command). When a receiving module in Cyclic Sleep wakes, it must detect the wake-up initializer in order to remain awake and
AT Command: ATHT
Binary Command: 0x03 (3 decimal)
(x 100 milliseconds)
Default Parameter Value: 0xFFFF (means that
long wake-up initializer will not be sent)
Number of bytes returned: 2
Related Commands: LH (Wake-up Initializer
Timer), SM (Sleep Mode), ST (Time before
Sleep) receive data. The value of HT Parameter tells the transmitter, “After a period of inactivity (no transmitting or receiving) lasting HT amount of time, send a long wake-up initializer”. HT
Parameter should be set to match the inactivity timeout (specified by ST (Time before Sleep)
Command) used by the receiver(s).
From the receiving module perspective, after HT time elapses and the inactivity timeout (ST command) is met, the receiver goes into cyclic sleep. In cyclic sleep, the receiver wakes once per sleep interval to check for a wake-up initializer. When a wake-up initializer is detected, the module will stay awake to receive data. The wake-up initializer must be longer than the cyclic sleep interval to ensure that sleeping modules detect incoming data. When HT time elapses, the transmitter then knows that it needs to send a long Wake-up Initializer for all receivers to be able to remain awake and receive the next transmission. Matching HT to the time specified by ST on the receiving module guarantees that all receivers will detect the next transmission.
ID (Modem VID) Command
<Networking and Security> Set/Read the VID
(Vendor Identification Number). Only modules with matching VIDs can communicate with each other. Modules with non-matching VIDs will not receive unintended data transmission.
AT Command: ATID
Binary Command: 0x27 (39 decimal)
Parameter Range (user-settable):
0x10 - 0x7FFFF
(Factory-set and read-only) :
0x8000 – 0xFFFF
Number of bytes returned: 2
Minimum Firmware Version Required: 4.2B
(previous firmware versions did not support user-settable IDs.)
IU (DI2, DI3 Update Timer) Command
<Serial Interfacing> Set/Read the interval at which the status of DI2, DI3 and Break is transmitted. Additionally, status is transmitted whenever there is a transition. A setting of “0” disables periodic update. DI2 or DI3 passing must be enabled for the update to take place.
AT Command: ATIU
Binary Command: 0x3B (59 decimal)
Parameter Range: 0 - 0xFFFF (x 100 ms)
Default Parameter Value: 0x0A (10 decimal)
Number of bytes returned: 2
Related Commands: BK (Serial Break Passing),
BO (Serial Break Timeout), CO (DO3 Timeout),
DR (Disconnect), RT (DI2 Configuration), TO
(DO2 Timeout)
Minimum Firmware Version Required: 4.30
© 2014 Digi International Inc.
28
XStream™ OEM RF Module – Product Manual v5.x00
LH (Wake-up Initializer Timer) Command
<Sleep (Low Power)> Set/Read the amount of time during which the RF initializer is sent. When receiving modules are put into Cyclic Sleep Mode, they power-down after a period of inactivity
(specified by ST (Time before Sleep) Command) and will periodically awaken and listen for transmitted data. In order for the receiving modules to remain awake, they must detect
~35ms of the wake-up initializer.
AT Command: ATLH
Binary Command: 0x0C (12 decimal)
Default Parameter Value: 1
Number of bytes returned: 1
LH Command must be used whenever a receiver is operating in Cyclic Sleep Mode. This lengthens the Wake-up Initializer to a specific amount of time (in tenths of a second). The Wake-up
Initializer Time must be longer than the cyclic sleep time that is determined by SM (Sleep Mode)
Command. If the wake-up initializer time were less than the Cyclic Sleep interval, the connection would be at risk of missing the wake-up initializer transmission.
Refer to the figures in the Sleep Mode sections (p13) to view correct and incorrect configuration diagrams. The images help visualize the importance that the LH value be greater than the SM cyclic sleep value.
MD (RF Mode) Command
<Networking and Security> The MD command is used to select/read the RF Mode (Peer-to-peer,
Multi-Stream or Repeater Modes) of the module.
Multi-Streaming Mode enables exclusive connections in point-to-multipoint networks.
Refer to the Multi-Streaming Mode section (p43) for more information regarding how these parameter values affect other parameter values.
Repeater Mode enables longer range via an intermediary module. When MD=3, the module will act as a “store and forward” repeater. Any packets not addressed to this node will be repeated. A Repeater End Node (MD=4) handles repeated messages, but will not forward the data over-the-air. Refer to the Repeater Mode section
(p38) for more information.
AT Command: ATMD
Binary Command: 0x32 (50 decimal)
Parameter Range: 0 – 4
Parameter Configuration
0
1
2
3
4
(transparent operation)
Multi-Stream Base
Multi-Stream Remote
Repeater and End Node
End Node
Default Parameter Value: 0
Number of bytes returned: 1
Related Commands: CB (Connection Duration
Timeout), CE (Connection Inactivity Timeout),
CM (Connection Message), DC (Disconnect)
Minimum Firmware Version Required: 4.30
MK (Address Mask) Command
<Networking and Security> MK Command is used to set/read the address mask of the module.
All data packets contain the destination address
(DT Parameter) of the transmitting module.
When an RF data packet is received, the transmitter’s destination address is logically
AT Command: ATMK
Binary Command: 0x12 (18 decimal)
Parameter Range: 0 – 0xFFFF
Default Parameter Value: 0xFFFF
(Destination address (DT parameter) of the transmitting module must exactly match the destination address of the receiving module.)
“ANDed” (bitwise) with the Address Mask of the receiver. The resulting value must match the destination address or the address mask of the receiver for the packet to be received and sent
Number of bytes returned: 2
Related Commands: DT (Destination Address),
HP (Hopping Channel), ID (Module VID), MY
(Source Address) out the module DO serial port. If the “ANDed” value does not match either the destination address or the address mask of the receiver, the packet is discarded. (All “0” values are treated as “irrelevant” values and are ignored.)
Refer to the Addressing Options section (p36) for more information.
© 2014 Digi International Inc.
29
XStream™ OEM RF Module – Product Manual v5.x00
MY (Source Address) Command
<Networking and Security> Set/Read the source address of the module.
Refer to the Addressing section (p36) of the RF
Communication Modes chapter for more information.
AT Command: ATMY
Binary Command: 0x2A (42 decimal)
Parameter Range: 0 – 0xFFFF
Default Parameter Value: 0xFFFF (Disabled – the DT (Destination Address) parameter serves as both source and destination address.)
Number of bytes returned: 2
Related Commands: DT (Destination Address),
HP (Hopping Channel), ID (Modem VID), MK
(Address Mask), AM (Auto-set MY)
Minimum Firmware Version Required: 4.30
NB (Parity) Command
<Serial Interfacing> Select/Read parity settings for UART communications.
PC (Power-up Mode) Command
<Command Mode Options> PC Command allows the module to power-up directly into AT
Command Mode from reset or power-on. If PC
Command is enabled with SM Parameter set to 1,
DI3 (pin 2) can be used to enter the module into
AT Command Mode. When the DI3 pin is de- asserted (low), the module will wake-up in AT
Command Mode. This behavior allows module
DTR emulation.
AT Command: ATNB
Binary Command: 0x23 (35 decimal)
Parameter Range: 0 – 5
Parameter
0
1
2
3
4
5
Configuration
8-bit (no parity or
7-bit (any parity)
8-bit even
8-bit odd
8-bit mark
8-bit space
9-bit
Default Parameter Value: 0
Number of bytes returned: 1
Minimum Firmware Version Required: 4.30
(previous versions did not support the 9 th bit.
AT Command: ATPC
Binary Command: 0x1E (30 decimal)
Parameter Range: 0 – 1
Parameter
0
Configuration
Power-up to Idle Mode
1
Default Parameter Value: 0
Number of bytes returned: 1
Minimum Firmware Version Required: 4.22
PK (RF Packet Size) Command
<Serial Interfacing> Set/Read the maximum size of the RF packets sent out a transmitting module. The maximum packet size can be used along with the RB and RO parameters to implicitly set the channel dwell time.
Changes to this parameter may have a secondary effect on the RB (Packet Control
Characters) parameter. RB must always be less than or equal to PK. If PK is changed to a value
AT Command: ATPK
Binary Command: 0x29 (41 decimal)
Parameter Range: 0 – 0x100 (Bytes)
Default Parameter Value: 0x40 (64 decimal)
Number of bytes returned: 2
Related Commands: RB (Packetization
Threshold), RO (Packetization Timeout)
Minimum Firmware Version Required: 4.30 less than the current value of RB, RB is automatically lowered to be equal to PK.
© 2014 Digi International Inc.
30
XStream™ OEM RF Module – Product Manual v5.x00
PW (Pin Wake-up) Command
<Sleep (Low Power)> Under normal operation, a module in Cyclic Sleep Mode cycles from an active state to a low-power state at regular intervals until data is ready to be received. If the
PW Parameter is set to 1, SLEEP (pin 2) can be used to wake the module from Cyclic Sleep. If the
SLEEP pin is de-asserted (low), the module will be fully operational and will not go into Cyclic
Sleep. Once SLEEP is asserted, the module will remain active for the period of time specified by
ST (Time before Sleep) Command and will return to Cyclic Sleep Mode (if no data is ready to be transmitted). PW Command is only valid if Cyclic
Sleep has been enabled.
AT Command: ATPW
Binary Command: 0x1D (29 decimal)
Parameter Range: 0 – 1
Parameter
0
1
Configuration
Disabled
Enabled
Default Parameter Value: 0
Number of bytes returned: 1
Minimum Firmware Version Required: 4.22
RB (Packetization Threshold) Command
<Serial Interfacing> RF transmission will commence when data is in the DI Buffer and
AT Command: ATRB
Binary Command: 0x20 (32 decimal) either of the following criteria are met: Parameter Range: 0 – 0x100 (bytes)
•
RO times out on the UART receive lines
(ignored if RO = 0)
(Maximum value equals the current value of PK
Parameter (up to 0x100 HEX (800 decimal))
•
RB characters have been received by the
UART (ignored if RB = 0)
If PK is lowered below the value of RB; RB is automatically lowered to match PK.
Default Parameter Value: 1
Number of bytes returned: 2
Related Commands: PK (RF Packet Size), RO
(Packetization Timeout)
Minimum Firmware Version Required: 4.30
Note: RB and RO criteria only apply to the first packet of a multi-packet transmission. If data remains in the DI Buffer after the first packet, transmissions will continue in streaming manner until there is no data left in the DI Buffer (UART receive buffer).
RE (Restore Defaults) Command
<Diagnostics> RE Command restores all AT Command: ATRE configurable parameters to factory default Binary Command: 0x0E (14 decimal) settings. However, RE Command will not write the restored values to non-volatile (persistent) memory. Issue the WR (Write) Command after the RE command to save restored parameter values to non-volatile memory.
RN (Delay Slots) Command
<Networking and Security> RN Command is only applicable if retries have been enabled (RR
(Retries) parameter > 0), or if forced delays will be inserted into a transmission (TT (Streaming
AT Command: ATRN
Binary Command: 0x19 (25 decimal)
Parameter Range: 0 – 0xFF (slots)
Default Parameter Value: 0
(no delay slots are inserted)
Limit) parameter > 0). RN Command is used to adjust the time delay that the transmitter inserts before attempting to resend a packet. If the transmitter fails to receive an acknowledgement
Number of bytes returned: 1
Related Commands: RR (Retries), TT
(Streaming Limit) after sending a packet, it will insert a random
Minimum Firmware Version Required: 4.22
number of delay slots (ranging from 0 to (RN minus 1)) before attempting to resend the packet. Each delay slot lasts for a period of 38ms.
If two modules attempted to transmit at the same time, the random time delay after packet failure would allow one of the two modules to transmit the packet successfully, while the other would wait until the channel opens up to begin transmission.
© 2014 Digi International Inc.
31
XStream™ OEM RF Module – Product Manual v5.x00
RO (Packetization Timeout) Command
<Serial Interfacing> Set/Read the time of silence
(no bytes received) after which transmission begins. After a serial byte is received and if no other byte is received before the RO timeout, the transmission will start.
AT Command: ATRO
Binary Command: 0x21 (33 decimal)
Parameter Range: 0 – 0xFFFF (x 200 µs)
Default Parameter Value: 0
Number of bytes returned: 2
Minimum Firmware Version Required: 4.2A
RP (RSSI PWM Timer) Command
<Diagnostics> RP Command is used to enable
PWM (Pulse Width Modulation) output on the
CONFIG pin. The output is calibrated to show the level the received RF signal is above the
AT Command: ATRP
Binary Command: 0x22 (34 decimal)
Parameter Range: 0 - 0x7F
(x 100 milliseconds)
Default Parameter Value: 0 (disabled) sensitivity level of the module. The PWM pulses vary from zero to 95 percent. Zero percent means the received RF signal is at or below the
Number of bytes returned: 1
Minimum Firmware Version Required: 4.2A
published sensitivity level of the module. The following table shows levels above sensitivity and PWM values.
The total period of the PWM output is 8.32 ms. Because there are 40 steps in the PWM output; the minimum step size is 0.208 ms.
Table 3‐03. PWM Chart
dBm above Sensitivity
10
20
30
PWM percentage
(high period / total period)
47.5%
62.5%
77.5%
A non-zero value defines the time that the PWM output will be active with the RSSI value of the last received RF packet. After the set time when no RF packets are received, the PWM output will be set low (0 percent PWM) until another RF packet is received. The PWM output will also be set low at power-up. A parameter value of 0xFF permanently enables the PWM output and it will always reflect the value of the last received RF packet.
PWM output shares the Config input pin. When the module is powered, the Config pin will be an input. During the power-up sequence, the Config pin will be read to determine whether the module is going into AT Command Mode. After this, if RP parameter is a non-zero value, the
Config pin will be configured as an output and set low until the first RF packet is received. With a non-zero RP parameter, the Config pin will be an input for RP ms after power up.
RR (Retries) Command
<Networking> Set/Read the number of retries that can be sent for a given RF packet. Once RR
AT Command: ATRR
Binary Command: 0x18 (24 decimal) command is enabled (set to a non-zero value),
RF packet acknowledgements and retries are
Parameter Range: 0 – 0xFF enabled. After transmitting a packet, the transmitter will wait to receive an
Default Parameter Value: 0 (disabled)
Number of bytes returned: 1 acknowledgement from a receiver. If the
Minimum Firmware Version Required: 4.22
acknowledgement is not received in the period of time specified by the RN (Delay Slots)
Command, the transmitter will transmit the original packet again. The packet will be transmitted repeatedly until an acknowledgement is received or until the packet has been sent RR times.
Note: For retries to work correctly, all modules in the system must have retries enabled.
© 2014 Digi International Inc.
32
XStream™ OEM RF Module – Product Manual v5.x00
RS (RSSI) Command
<Diagnostics> Read the signal level of the last packet received. This reading is useful for determining range characteristics of the modules under various conditions of noise and distance.
Once the command is issued, the module will return a value between 0x06 and 0x36.
(“0x36” represents a very strong signal level and “0x06” indicates a low signal level.)
AT Command: ATRS
Binary Command: 0x1C (28 decimal)
Parameter Range: 0x06 – 0x36 (read-only)
Number of bytes returned: 1
Minimum Firmware Version Required: 4.22
RT (DI2 Configuration) Command
<Serial Interfacing> RT command is used to dictate the behavior of the DI2/ /CMD line. RT
Command must be issued to enable control or binary programming. flow
RZ (DI Buffer Size) Command
<Diagnostics> The RZ command is used to read the size of the DI buffer (UART RX (Receive)).
Note: The DO buffer size can be determined by multiplying the DI buffer size by 1.5.
SB (Stop Bits) Command
<Serial Interfacing> Set/Read the number of stop bits in the RF data packets.
SH (Serial Number High) Command
<Diagnostics> Set/Read the serial number high word of the module.
AT Command: ATRT
Binary Command: 0x16 (22 decimal)
Parameter Range: 0 – 2
Parameter
0
1
2
Configuration disabled
Enable Binary Programming
Enable Flow Control
Default Parameter Value: 0
Number of bytes returned: 1
AT Command: ATRZ
Binary Command: 0x2C (44 decimal)
Parameter Range: Read-only
Number of bytes returned: 2
Minimum Firmware Version Required: 4.30
AT Command: ATSB
Binary Command: 0x36 (54 decimal)
Parameter Range: 0 – 1
Parameter
0
1
Configuration
1 stop bits
2 stop bits
Default Parameter Value: 0
Number of bytes returned: 1
Minimum Firmware Version Required: 4.2B
AT Command: ATSH
Binary Command: 0x25 (37 decimal)
Parameter Range: 0 – 0xFFFF (read-only)
Number of bytes returned: 2
Related Commands: SL (Serial Number Low)
Minimum Firmware Version Required: 4.27C
© 2014 Digi International Inc.
33
XStream™ OEM RF Module – Product Manual v5.x00
SL (Serial Number Low) Command
<Diagnostics> Set/Read the serial number low word of the module.
AT Command: ATSH
Binary Command: 0x26 (38 decimal)
Parameter Range: 0 – 0xFFFF (read-only)
Number of bytes returned: 2
Related Commands: SH (Serial Number High)
Minimum Firmware Version Required: 4.27C
SM (Sleep Mode) Command
<Sleep Mode (Low Power)> Set/Read Sleep Mode
Settings. By default, Sleep Mode is disabled and the module remains continually active.
SM Command allows the module to run in a lower-power state and to be configured in one of eight settings.
Cyclic Sleep settings wake the module after the amount of time designated by SM Command. If the module detects a wake-up initializer during the time it is awake, it will synchronize with the transmitter and start receiving data after the wake-up initializer runs its duration. Otherwise, it returns to Sleep Mode and continues to cycle in and out of inactivity until the Wake-up Initializer is detected. If a Cyclic Sleep setting is chosen, the ST, LH and HT parameters must also be set as described in the “Sleep Mode” section of this manual.
Refer to the Sleep Mode sections for more information.
AT Command: ATSM
Binary Command: 0x01
Parameter Range: 0 – 8
Parameter
0
1
2
3
4
5
6
7
8
Configuration
Disabled
Pin Sleep
Serial Port Sleep
Cyclic 0.5 second sleep
(Module wakes every 0.5 seconds)
Cyclic 1.0 second sleep
Cyclic 2.0 second sleep
Cyclic 4.0 second sleep
Cyclic 8.0 second sleep
Cyclic 16.0 second sleep
Default Parameter Value: 0
Number of bytes returned: 1
Related Commands:
Pin Sleep – PC (Power-up Mode), PW (Pin
Wake-up)
Serial Port Sleep – ST (Time before Sleep)
Cyclic Sleep – ST (Time before Sleep), LH
(Wake-up Initializer Timer), HT (Time Before
Wake-up Initializer), PW (Pin Wake-up)
ST (Time before Sleep) Command
<Sleep Mode (Low Power)> Set/Read the period of time in which the module remains inactive before entering into Sleep Mode. For example: If the ST parameter is set to 0x64 (100 decimal), the module will enter into Sleep mode after 10 seconds of inactivity (no transmitting or receiving). This command can only be used if
Cyclic Sleep or Serial Port Sleep Mode settings have been selected using the SM command.
AT Command: ATST
Binary Command: 0x02
Parameter Range: 0x10 – 0xFFFF
(x 100 milliseconds)
Default Parameter Value: 0x64 (100 decimal)
Number of bytes returned: 2
Related Commands: SM (Sleep Mode), LH
(Wake-up Initializer Timer), HT (Time before
Wake-up Initializer)
© 2014 Digi International Inc.
34
XStream™ OEM RF Module – Product Manual v5.x00
SY (Time before Initialization) Command
<Networking and Security> SY Command keeps a communication channel open as long as module transmits or receives before the active connection expires. It can be used to reduce latency in a query/response sequence and should be set 100 ms longer than the delay between transmissions.
This command allows multiple XStream Modules
AT Command: ATSY
Binary Command: 0x17 (23 decimal)
Parameter Range: 0 – 0xFF
(x 100 milliseconds)
Default Parameter Value: 0 (Disabled - channel
initialization info sent with each RF packet.)
Number of bytes returned: 1 to share a hopping channel for a given amount of time after receiving data. By default, all packets include an RF initializer that contains channel information used to synchronize any listening receivers to the transmitter’s hopping pattern. Once a new module comes within range, it is able to instantly synchronize to the transmitter and start receiving data. If no new modules are introduced into the system, the synchronization information becomes redundant once modules have become synchronized.
SY Command allows the modules to remove this information from the RF Initializer after the initial synchronization. For example, changing the SY Parameter to 0x14 (20 decimal) allows all modules to remain in sync for 2 seconds after the last data packet was received. Synchronization information is not re-sent unless transmission stops for more than 2 seconds. This command allows significant savings in packet transmission time.
Warning: Not recommended for use in an interference-prone environment. Interference can break up the session and the communications channel will not be available again until SY time expires.
With SY set to zero, the channel session is opened and closed with each transmission - resulting in a more robust link with more latency.
TO (DO2 Timeout) Command
<Serial Interfacing>DO2 output will return to default after no DI2 status information is received during the timeout period.
Use with CS = 2 or 4.
AT Command: ATTO
Binary Command: 0x31 (49 decimal)
Parameter Range: 0 – 0xFFFF (x 1 second)
Default Parameter Value: 3
Number of bytes returned: 2
Minimum Firmware Version Required: 4.30
TR (Transmit Error Count) Command
<Diagnostics> Read number of retransmit failures. The number of retransmit errors is incremented each time a packet is not acknowledged within the number of retransmits specified by the RR (Retries) parameter. It therefore counts the number of packets that were not successfully received and have been dropped.
AT Command: ATTR
Binary Command: 0x1B (27 decimal)
Parameter Range: 0 – 0xFFFF
Default Parameter Value: 0
Number of bytes returned: 2
Related Commands: RR (Retries)
Minimum Firmware Version Required: 4.22
The TR parameter is not non-volatile and therefore is reset to zero each time the module is reset.
© 2014 Digi International Inc.
35
XStream™ OEM RF Module – Product Manual v5.x00
TT (Streaming Limit) Command
<Networking and Security> Set/Read the number of bytes that can be sent out before a random delay is issued. TT Command is used to simulate full-duplex behavior.
If a module is sending a continuous stream of RF data, a delay is inserted (transmission is stopped,
AT Command: ATTT
Binary Command: 0x1A (26 decimal)
Parameter Range: 0 – 0xFFFF (bytes)
Default Parameter Value: 0xFFFF (65535d)
Number of bytes returned: 2
Related Commands: RN (Delay Slots)
Minimum Firmware Version Required: 4.22 allowing other modules time to transmit (once it sends number of bytes specified by TT Command). Inserted random delay lasts between 1 and ‘RN
+ 1’ delay slots, where each delay slot lasts 38 ms.
VR (Firmware Version) Command
<Diagnostics> Read the Firmware Version of the module.
AT Command: ATVR
Binary Command: 0x14 (20 decimal)
Parameter Range: 0 – 0xFFFF (read-only)
Number of bytes returned: 2
WR (Write) Command
<(Special)> WR Command writes configurable parameters to the module’s non-volatile memory
AT Command: ATWR
Binary Command: 0x08
(Parameter values remain in the module’s memory until overwritten by future use of WR Command).
If changes are made without writing them to non-volatile memory, the module reverts back to previously saved parameters the next time the module is powered-on.
© 2014 Digi International Inc.
36
XStream™ OEM RF Module – Product Manual v5.x00
4. RF Communication Modes
Network configurations covered in this chapter are described in terms of the following:
•
Network Topology (Point-to-Point, Point-to-Multipoint or Peer-to-Peer)
•
RF Communication Type (Basic or Acknowledged)
•
RF Mode (Streaming, Repeater, Acknowledged or Multi-Streaming)
The following table provides a summary of the network configurations supported.
Table 4‐01. Summary of network configurations supported by the XStream OEM RF Module
Point-to-Point
Definition
Sample Network Profile *
(Broadcast Communications)
Sample Network Profile *
(Acknowledged Communications)
Basic Communication RF Modes
Acknowledged Communication RF Mode
An RF data link between two modules.
Use default values for all modules.
All Modules: ATAM (auto-set MY (Source Address) parameter) **
ATDT FFFF (set Destination Address to 0xFFFF)
Streaming Mode (p37), Repeater Mode (p38)
Acknowledged Mode (p41)
Point-to-Multipoint
Definition RF data links between one base and multiple remotes.
Base: ATMY 0 (set Source Address to 0x00)
ATDT FFFF (set Destination Address to 0xFFFF) Sample Network Profile *
(Basic Communications)
Remotes: ATAM (auto-set MY (Source Address) parameter) **
ATDT 0 (set Destination Address to 0x00)
Base: ATMY 0 (set Source Address to 0x00)
ATDT FFFF (set Destination Address to 0xFFFF)
ATRR 3 (set number of Retries to 3) Sample Network Profile *
(Acknowledged Communications)
Basic Communication RF Modes
Remotes: ATAM (auto-set MY (Source Address) parameter) **
ATDT 0 (set Destination Address to 0x00)
ATRR 3 (set number of Retries to 3)
Streaming Mode (p37), Repeater Mode (p38)
Acknowledged Communication RF Modes Acknowledged Mode (p41), Multi-Streaming Mode (p43)
Peer-to-Peer
Definition
Sample Network Profile *
(Basic Communications)
Modules remain synchronized without use of a master/server. Each module shares the roles of master and slave. Digi’s peer-to-peer architecture features fast synch times (35ms to synchronize modules) and fast cold start times (50ms before transmission).
Use default values for all modules.
Sample Network Profile *
(Acknowledged Communications)
Basic Communication RF Mode
Acknowledged Communication RF Mode
All Modules: ATAM (auto-set MY (Source Address) parameter) **
ATDT FFFF (set Destination Address to 0xFFFF)
ATRR 3 (set number of Retries to 3)
Streaming Mode (p37)
Acknowledged Mode (p41)
* Assume default values for parameters not listed. Profiles do not reflect addressing implementations.
** AM (Auto‐set MY) Command must be issued through a terminal program such as the one incorporated in the XCTU “Terminal” tab.
© 2014 Digi International Inc.
37
XStream™ OEM RF Module – Product Manual v5.x00
4.1. Addressing
Each RF packet contains addressing information that is used to filter incoming RF data. Receiving modules inspect the Hopping Channel (HP parameter), Vendor Identification Number (ID parameter) and Destination Address (DT parameter) contained in each RF packet. Data that does not pass through all three network security layers is discarded.
Figure 4‐01. Filtration layers contained in the RF packet header
4.1.1. Address Recognition
Transmissions can be addressed to a specific module or group of modules using the DT
(Destination Address) and MK (Address Mask) parameters. The transmitting module dictates whether the packet is intended for a specific module (local address) or multiple modules (global address) by comparing the packet’s DT parameter to its own MK parameter.
Figure 4‐02. Local Packets vs. Global Packets (Transmitting Module)
TX_DT = Transmitter Destination Address
TX_MK = Transmitter Address Mask
Note: When TX_DT = 0xFFFF (default), RF packets are global and are received by all modules within range. (Receivers do not send
ACKs.)
A receiving module will only accept a packet if a packet is addressed to it (either as a global or local packet). The RX module makes this determination by inspecting the destination address of the RF packet and comparing it to its own address and mask. The Destination Address of the TX module is logically “ANDed” with the Address Mask of the RX module.
Figure 4‐03. Address Recognition (Receiving Module)
TX_DT = Transmitter Destination Address
RX_DT = Receiver Destination Address
RX_MY = Receiver Source Address
Note: For more information regarding addressing and masks, refer to Application Note “XST-
AN004b” (located on the web at: www.digi.com.)
© 2014 Digi International Inc.
38
XStream™ OEM RF Module – Product Manual v5.x00
4.2. Basic Communications
Basic Communications are accomplished through two sub-types:
•
Broadcast - By default, XStream Modules communicate through Broadcast communications and within a peer-to-peer network topology. When any module transmits, all other modules within range will receive the data and pass it directly to their host device.
•
Addressed - If addressing parameters match, received RF data is forwarded to the DO (Data
Out) buffer; otherwise, the RF data is discarded.
When using Basic Communications, any functions such as acknowledgements are handled at the application layer by the OEM/integrator. The Broadcast Modes provide transparent communications, meaning that the RF link simply replaces a wired link.
4.2.1. Streaming Mode (Default)
Characteristics: Highest data throughput
Lowest latency and jitter
Reduced immunity to interference
Transmissions never acknowledged (ACK) by receiving module(s)
Required Parameter Values (TX Module): RR (Retries) = 0
Related Commands: Networking (DT, MK, MY), Serial Interfacing (PK, RB, RO, TT)
Recommended Use: Mode is most appropriate for data systems more sensitive to latency and/or jitter than to occasional packet loss. For example: streaming audio or video.
Streaming Mode Data Flow
Figure 4‐04. Streaming Mode State Diagram (TX Module)
Events and processes in this mode are common to all of the
other RF Modes.
Note: When streaming data, RB and RO parameters are only observed on the first packet.
After transmission begins, the TX event will continue uninterrupted until the DI buffer is empty or the streaming limit
(TT Command) is reached. As with the first packet, the payload of each subsequent packet includes up to the maximum packet size (PK Command).
The streaming limit (TT Command) is specified by the transmitting module as the maximum number of bytes the transmitting module can send in one transmission event. After the TT parameter threshold is reached, the transmitting module will force a random delay of 1 to RN delay slots (exactly 1 delay slot if RN = 0).
Subsequent packets are sent without an RF initializer since receiving modules stay synchronized with the transmitting module for the duration of the transmission event (from preceding packet information). However, due to interference, some receiving modules may lose data (and synchronization to the transmitting module), particularly during long transmission events.
© 2014 Digi International Inc.
39
XStream™ OEM RF Module – Product Manual v5.x00
Once the transmitting module has sent all pending data or has reached the TT limit, the transmission event ends. The transmitting module will not transmit again for exactly RN delay slots if the local (i.e. transmitting module’s) RN parameter is set to a non-zero value. The receiving module(s) will not transmit for a random number of delay slots between 0 and (RN-1) if the local (i.e. receiving module’s) RN parameter is set to a non-zero value. These delays are intended to lessen congestion following long bursts of packets from a single transmitting module, during which several receiving modules may have become ready to transmit.
4.2.2. Repeater Mode
Characteristics: Self-organizing - No route configuration is necessary
Self-healing / Fault-tolerant
Low power consumption and Minimized interference
Network throughput is determined by number of hops, not by number of repeaters. Multiple repeaters within range of source node count as one hop.
Supports “transparent” multi-drop mode or addressed data filtering mode.
Duplicate RF packets are automatically filtered out.
All packets propagate to every node in the network (filtering rules apply).
Broadcast communications - each packet comes out every node exactly once.
Addressed communications - all radios see every packet. Only the module with a matching address will forward it to the DO buffer (UART IN).
Data entering the network on any module is transmitted and forwarded through every repeater module until it reaches the ends of the network.
Each repeater will repeat a packet only once.
Constraints: Requires that each module have a unique MY (Source Address) parameter.
System must introduce just one packet at a time to the network for transmission (256 bytes max).
Each hop (H) decreases network throughput by a factor of 1/(H+1).
Additional repeaters add network redundancy without decreasing throughput.
Required Parameter Values (TX Module): MD = 3 or 4, MY = unique value (can be accomplished by issuing the AM (Auto-set MY) and WR (Write) commands to all modules in the network)
Related Commands: Networking (MD, DT, MY, AM), Serial Interfacing (RN, PK, RO, RB)
Recommended Use: Use in networks where intermediary nodes are needed to relay data to modules that are beyond the transmission range of the base module.
Theory of Operation
OEMs and integrators can extend the effective range and reliability of a data radio system by forwarding traffic through one or more repeaters.
Instead of using routing tables and path discovery to establish dynamic paths through a network, the repeater system uses a sophisticated algorithm to propagate each RF packet through the entire network.
The network supports RF packets up to 256 bytes. The repeater network can operate using broadcast or addressed communications for multi-drop networks and works well in many systems with no special configuration.
When in Repeater Mode, the network repeats each message among all available nodes exactly one time. This mechanism eliminates the need for configuring specific routes. The network is self- organizing and self-healing so that the system is able to receive transmissions in the event of a module going down.
© 2014 Digi International Inc.
40
XStream™ OEM RF Module – Product Manual v5.x00
Figure 4‐05. Sample Repeater Network Topology
Repeater Network Configuration
A network may consist of End Nodes (EN), End/Repeater Nodes (ERN) and a Base Node (BN).
The base node initiates all communications.
The repeater network can be configured to operate using Basic Broadcast or Basic Addressed communications. The addressing capabilities of the modules allow integrators to send a packet as a global packet (DT = 0xFFFF) and shift out of every radio in the network (Basic Broadcast).
Alternatively, the packet can be sent with a specific DT (Destination Address) parameter so that it is only accepted by a specific remote node (Basic Addressed).
Configuration Instruction (Basic Broadcast Communications)
Assign each module a unique MY (source) address. (The AM (Auto-set MY) command will configure a unique source address that is based on module serial number.)
Enable Basic Broadcast Communications (DT = 0xFFFF) or Addressed Broadcast Communications
(ATDT specifies a specific destination)
Configure PK, RO and RB to ensure that RF packet aligns with protocol packet. (ex. PK=0x100,
RB=0x100, RO depends on baud rate).
Configure one or more repeaters in the system (ATMD = 3).
Configure remote nodes as destinations (MD = 4). This will ensure that the remote node waits for the repeater traffic to subside before it transmits a response.
Assign each module a unique MY (source) address. (The AM (Auto-set MY) command will configure a unique source address that is based on module serial number.)
Enable Basic Broadcast Communications (DT = 0xFFFF) or Addressed Broadcast Communications
(ATDT specifies a specific destination)
Configure PK, RO and RB to ensure that RF packet aligns with protocol packet. (ex. PK=0x100,
RB=0x100, RO depends on baud rate).
Configure one or more repeaters in the system (ATMD = 3).
Configure remote nodes as destinations (MD = 4). This will ensure that the remote node waits for the repeater traffic to subside before it transmits a response.
The configuration instructions above reflect configuration for a Basic Broadcast Repeater system.
To configure a Basic Addressed Repeater system, use the DT (Destination Address) parameter to assign unique addresses to each module in the network.
Algorithm details
•
Packet ID (PID) is composed of transmitting module MY address and packet serial number.
•
Incoming packets with a PID already found in the PID buffer will be ignored.
•
Each module maintains a PID buffer 8 deep of previously received packets (managed as
FIFO).
Packets may be shifted out the serial port and/or repeated depending on the DT parameter contained in the RF packet.
© 2014 Digi International Inc.
41
XStream™ OEM RF Module – Product Manual v5.x00
Table 4‐02. DT (Destination Address) parameter truth
table
Address Match
Global
Local
None
Send out serial port?
Yes
Yes
No
Repeat?
Yes
No
Yes
Repeat delay based on RSSI
A transmitted packet may be received by more that one repeater at the same time. In order to reduce the probability that the repeaters will transmit at the same instant, resulting in a collision and possible data loss; an algorithm has been developed that will allow a variable back-off prior to retransmission of the packet by a repeater. The algorithm allows radios that receive the packet with a stronger RF signal (RSSI) to have the first opportunity to retransmit the packet.
The RN (Delay Slots) parameter is used to configure this delay. Set RN=0 (no delays) for small networks with few repeaters or repeaters that are not within range of each other. Set RN=1 for systems with 2 to 5 repeaters that may be within range of each other.
The actual length of the delay is computed by the formula:
Delay (ms) = L * DS
DS = (-41-RSSI)/10*RN)+RandomInt(0,RN)
Where L is the length of the transmitted packet in milliseconds, DS is the number of delay slots to wait, RSSI is the received signal strength in dBm, RN is the value of the RN register and
RandomInt(A,B) is a function that returns a random integer from A to B-0
© 2014 Digi International Inc.
42
XStream™ OEM RF Module – Product Manual v5.x00
Response packet delay
As a packet propagates through the repeater network, if any node receives the data and generates a quick response, the response needs to be delayed so as not to collide with subsequent retransmissions of the original packet. To reduce collisions, both repeater and end node radios in a repeater network will delay transmission of data shifted in the serial port to allow any repeaters within range to complete their retransmissions.
The time for this delay is computed by the formula:
Maximum Delay (ms) = L * DS
DS = ((-41-(-100))/10)*RN)+RN+1
Where L is the length of the transmitted packet in milliseconds, DS is the number of delay slots to wait, RSSI is the received signal strength in dBm, and RN is the value of the RN register.
Use Case - Broadcast Repeater Network
Consider modules R1 through R10 each communicating to a PLC using the ModBus protocol and spaced evenly in a line. All ten nodes are configured as “destinations and repeaters” within the scope of Basic Broadcast Communications (MD=3, AM, DT=0xFFFF, PK=0x100, RO=0x03,
RB=0x100, RN=1). The Base Host (BH) shifts payload that is destined for R10 to R1. R1 initializes RF communication and transmits payload to nodes R2 through R5 which are all within range of R1. Modules R2 through R5 receive the RF packet and retransmit the packet simultaneously. They also send the data out the serial ports, to the PLC's.
Table 4‐03. Commands used to configure repeater functions
AT
Command
AM
DT
MD
MY
RN
WR
Binary
Command
0x3A (58d)
0x00 (0d)
0x3C (60d)
0x2A (42d)
0x19 (25d)
0x08 (8d)
AT Command Name
Auto-set MY
Destination Address
RF Mode
Source Address
Delay Slots
Write
Range
-
0 – 0xFFFF
3 - 4
0 – 0xFFFF
0 – 0xFF (slots)
-
# Bytes
Returned
1
2
-
2
1
-
Factory
Default
0
-
-
0
0
0xFFFF
Bandwidth Considerations
Using broadcast repeaters in a network reduces the overall network data throughput as each repeater must buffer an entire packet before retransmitting it. For example: if the destination is within range of the transmitter and the packet is 32 bytes long, the transmission will take 72ms on a 9600 baud XStream Module (much faster modules are available). If that same packet has to propagate through two repeaters, it will take 72ms to arrive at the first repeater, another 72 ms to get to the second and a final 72ms to get to the destination for a total of 216ms. Taking into account UART transfer times (~1ms/byte at 9600 baud), a server to send a 32 byte query and receive a 32 byte response is ~200ms, allowing for 5 polls per second. With the two repeaters in the path, the same query/response sequence would take about 500ms for 2 polls per second.
To summarize, this system is sending and receiving 64 bytes 5 times per second for a throughput of 320 bytes per second with no repeaters and 128 bytes per second with 2 repeaters. Generally, the network throughput will decrease by a factor of 1/(R+1), with R representing the number of repeaters between the source and destination.
Note that these numbers are absolutely worst case to illustrate how the system would perform in a typical, low bandwidth system. As a counter example the 115kbps 9XTend radio can transfer the same 32 byte packet in 12 ms for a round trip with UART transfer times of ~30ms or 33 polls per second (1066 bytes per second) with no repeaters. With two repeaters the time would be
~100ms round trip time for 10 polls per second or 320 bytes per second network throughput with two repeaters.
© 2014 Digi International Inc.
43
XStream™ OEM RF Module – Product Manual v5.x00
4.3. Acknowledged Communications
4.3.1. Acknowledged Mode
Characteristics: Reliable delivery through positive acknowledgements for each packet
Throughput, latency and jitter vary depending on the quality of the channel and the strength of the signal.
Recommended Use: Acknowledge Mode configuration is appropriate when reliable delivery is required between modules. If messages are smaller than 256 bytes, use RB and RO commands to align RF packets with application packets.
Required Parameter Values (TX Module): RR (Retries) >= 1
Related Commands: Networking (DT, MK, RR), Serial Interfacing (PK, RN, TT, RO, RB)
Table 4‐04. Sample Network Profile
Module
All
Parameter Settings (assume default values for parameters not listed)
ATRR A (set number of Retries to 0x0A)
ATRN 5 (set number of Delay Slots to 5)
Acknowledged Mode Connection Sequence
Figure 4‐06. Acknowledged Mode State Diagram
After sending a packet while in Acknowledged
Mode, the transmitting module listens for an ACK
(acknowledgement). If it receives the ACK, it will either send a subsequent packet (if more transmit data is pending), or will wait for exactly RN random delay slots before allowing another transmission (if no more data is pending for transmission).
© 2014 Digi International Inc.
44
XStream™ OEM RF Module – Product Manual v5.x00
If the transmitting module does not receive the ACK within the allotted time, it will retransmit the packet with a new RF initializer following the ACK slot. There is no delay between the first ACK slot and the first retransmission. Subsequent retransmissions incur a delay of a random number of delay slots, between 0 and RN. If RN is set to 0 on the transmitting module, there are never any back-off delays between retransmissions. Note that during back-off delays, the transmitting module will go into Idle Mode and may receive RF data. This can have the effect of increasing the back-off delay, as the radio cannot return to RF transmit (or retransmit) mode as long as it is receiving RF data.
After receiving and acknowledging a packet, the receiving module will move to the next frequency and listen for either a retransmission or new data for a specific period of time. Even if the transmitting module has indicated that it has no more pending transmit data, it may have not received the previous ACK, and so it may retransmit the packet (potentially with no delay after the ACK slot). In this case, the receiving module will always detect the immediate retransmission, which will hold off the communications channel and thereby reduce collisions. Receiving modules acknowledge each retransmission they receive, but they only pass the first copy of a packet they receive out the UART.
RB and RO parameters are not applied to subsequent packets. This means that once transmission has begun, it will continue uninterrupted until the DI buffer is empty or the streaming limit (TT) has been reached. As with the first packet, the payload of each subsequent packet includes up to the maximum packet size (PK parameter). The transmitting module checks for more pending data near the end of each packet.
The streaming limit (TT parameter) specifies the maximum number of bytes that the transmitting module will send in one transmission event, which may consist of many packets and retries. If the TT parameter is reached, the transmitting module will force a random delay of 1 to RN delay slots (exactly 1 delay slot if RN is zero). Each packet is counted only once toward TT, no matter how many times the packet is retransmitted.
Subsequent packets in acknowledged mode are similar to those in streaming mode, with the addition of an acknowledgement between each packet, and the possibility of retransmissions.
Subsequent packets are sent without an RF initializer, as the receiving modules are already synchronized to the transmitting module from the preceding packet(s) and they remain synchronized for the duration of the transmission event. Each retransmission of a packet includes an RF initializer.
Once the transmitting module has sent all pending data or has reached the TT limit, the acknowledged transmission event is completed. The transmitting module will not transmit again for exactly RN delay slots, if the local RN parameter is set to a nonzero value. The receiving module will not transmit for a random number of delay slots between 0 and (RN-1), if the local
RN parameter is set to a nonzero value. These delays are intended to lessen congestion following long bursts of packets from a single transmitting module, during which several receiving modules may have themselves become ready to transmit.
© 2014 Digi International Inc.
45
XStream™ OEM RF Module – Product Manual v5.x00
4.3.2. Multi-Streaming Mode
Characteristics: Enables exclusive connections (refer to “Operation” section for definition) Supports the passing of large data streams (> 256 bytes) from multiple remote modules to a base module (If a complete data stream from a remote module is less than 256 bytes, data can be sent from several remotes to a base location without enabling this mode and latencies will be much less.)
Transmissions never acknowledged (ACK) by receiving module(s)
Required Parameter Values (TX Module): MD = 1 (Base), MD = 2 (Remote), RN > 0, RR
> 0, MY ≠ 0xFFFF
Recommended Use: Use this mode in point-to-multipoint networks where remote modules initiate communications and require exclusive (uninterrupted) connections to the base module.
Table 4‐05. Sample Network Profile
Module
Base
Remotes
Parameter Settings (assume default values for parameters not listed)
ATMD 1 (configure module as Multi-Stream Base) *
ATMD 2 (configure module as Multi-Stream Remote) *
* When Multi‐Streaming is enabled, the following parameters are consequently modified (if they have not already been modified from their default states): RR, RN, MY, CD, AT and BT. (refer to Table 4‐
06)
Theory of Operation
When in Multi-Streaming Mode, all remote modules can initiate communications with the base module at the same time, but only one remote is granted an exclusive connection.
After an exclusive connection begins, data is transferred exclusively between two modules without interruption from any other modules in the network.
An exclusive connection is a bi-directional connection that can only be established when in
Multi- Streaming Mode. An exclusive connection is immune to other remote modules interrupting the connection and interleaving data (The interleaved data potentially renders the base module unable to discern from which remote module the data was transmitted).
When an exclusive connection is granted to a single remote, the other remotes are notified that the connection exists. The notification causes the remote modules to postpone transmissions until the base module sends notification that the exclusive connection has ended.
Figure 4‐07. Sample Connection Sequence Diagram
CRP = Connection Request Packet
CGP = Connection Grant Packet
DRP = Disconnect Request Packet (not shown in diagram – applicable when remote connection is disconnected using the pin sleep I/O line.
DGP = Disconnect Grant Packet
ACK = Acknowledgement of reception.
Base module = The central transmitting/receiving module in a network of modules that maintains communications with remote modules.
Remote module = A module in a network that sends data to and receives data from a base module.
Payload = Data contained inside the RF
Data of the RF Packet that originates from a host to be transmitted over‐the‐air.
© 2014 Digi International Inc.
46
XStream™ OEM RF Module – Product Manual v5.x00
In the connection sequence above, an exclusive connection is first granted to “Remote m”.
The CGP (Connection Grant Packet) is broadcast to all remote modules in the network to communicate the base in engaged in an exclusive connection. Upon receipt of the CGP notification, remote modules will wait for a DGP (Disconnect Grant Packet) before attempting again to send data to the base module.
Initiating a Connection
Connection Guidelines:
•
A remote module can only request a connection with the base module.
•
The base module may hold off or grant a connection request to another module.
•
A remote module will not try to establish a connection if one already exists.
•
A connection fails if no response is received after RR (Retries) CRP packets. After a failure, whatever condition was causing a connection to be established is cleared. If the condition was data to be sent, all data in the DI buffer will be flushed. If the condition was DI3 transition, then no connection will be attempted until another correct DI3 transition.
•
A global connection cannot fail. (Definition is on next page.)
Once in Multi-Streaming Mode (MD > 0), several events can initiate an exclusive connection:
Remote module has payload to transmit. After a remote module receives data from its host, the module will attempt to establish a connection with the base module. The connection is defined by the remote’s DT (Destination Address) parameter. If another remote has a connection with the base, no connection will be established until the connection runs its course. Any remotes requesting a connection will then arbitrate for the next connection. RR
(Retries) and RN (Random back-off) parameters control this arbitration.
Base sets the DT (Destination Address) parameter. When the base module sets the DT
(Destination Address) parameter, an exclusive connection is immediately initiated with the remote module that has a matching DT parameter. After the DT command is sent (If
ATCM=1), the base module indicates a successful connection with a “CONNECT XXXX” string where "XXXX" is the remote's address. An unsuccessful connection is indicated with an
“ERROR” string. If the connection is successful, the module immediately exits AT Command
Mode and data can be sent to and received from the connected remote module. If an error is returned, the module stays in AT Command Mode. If a base is connected to a remote when the DT command is executed, the current connection is disconnected before a new connection is created.
DI3 pin (pin 2, SLEEP) is asserted (set low). Both base and remote modules can create a connection (defined by the current DT (Destination Address) parameter) when the DI3 pin is asserted (driven high). DR (DI3 Configuration) Command is used to establish this mode. If a remote asserts DI3, a connection request will be sent when no connection is active. If the base asserts DI3, a connection will immediately be established with the remote after any connection.
© 2014 Digi International Inc.
47
XStream™ OEM RF Module – Product Manual v5.x00
Initiating a Disconnection
To disconnect, the base module sends a DGP (disconnect grant packet). A remote module can only request a disconnect. The following conditions cause a disconnect:
No over-the-air data sent or received for CE (Connection Inactivity Timeout) time. If no overthe-air data is successfully sent (no acknowledgement received) or received (any good packet) for CE time, the connection will be dropped. Only a base module can detect this condition. Refer to CE Command.
Absolute CB (Connection Duration Timeout). The CB parameter defines an absolute timeout.
A timer is started on the remote units when a connection is established. When the connection has been active for CB time, the base will close the connection. A remote that detects this condition will automatically disconnect (it will not send a DRP (disconnect request packet)). Remotes that monitor a connection between the base and another remote will disregard any connection after the CB time. Refer to CB Command.
DI3 pin (pin 2, SLEEP) is de-asserted (set high). A base or remote module can cause a disconnect by setting the DI3 line high. If no connection is active, the de-assertion is ignored. A remote will request a disconnect if DI3 is de-asserted and the remote is currently connected the base. Refer to DR (DI3 Configuration) Command.
A remote or a base module receives the ATDC (Disconnect) Command.
Configuration
AT Command Mode
AT command mode is used for all commands on base and remote modules. Binary command mode is not available when MD = 1 or 2.
The base is in AT command mode when not engaged in an exclusive connection with a remote.
No AT Command Mode sequence is needed. When a base module is connected to a remote module, the AT Command Mode sequence is used to enter AT command mode. The connection with the remote is maintained. Care should be taken that the CE (Connection Inactivity) timeout does not occur while in AT Command Mode.
The remote must use the AT command sequence to enter AT Command Mode. When a connection exists with a base module, the connection is maintained. Care must be taken that the
CB (Connection Duration) timeout does not occur while in AT Command Mode.
As of firmware version, 4.30, a faster method is available for entering AT Command Mode. If the
BT and AT parameters are set to 0, BT (Guard Time Before) and AT (Guard Time After) times are set to 6 milliseconds.
Beware that this will also mean that AT Command Mode cannot be entered by manually typing the AT command sequence (usually “+++”), because the AT time will occur faster than the characters can be typed.
Auto Configuration
When enabling Multi-Streaming Modes (by setting the MD (RF Mode) parameter to 1 or 2), other parameter values are automatically modified to support the mode. For example, when the MD parameter is changed to 1 or 2, the RR parameter is changed to 0x0A (hex). The modification only occurs if the RR parameter is 0 (its default) before the MD command was executed. If any other value is found for the RR parameter, the RR parameter will not be changed. Auto configuration occurs every time the module is powered-up.
© 2014 Digi International Inc.
48
XStream™ OEM RF Module – Product Manual v5.x00
Table 4‐06. Auto Configurations
Parameter changed
when MD = 1 or 2
RR (Retries)
RN (Delay Slots)
MY (Source Address)
CD (DO3 Configuration)
BT (Guard Time Before)
AT (Guard Time After)
Condition for modification
to take place (default values)
If RR = 0
If RN = 0
If MY = 0xFFFF (and MD = 2)
If CD = 0
If BT = 0x0A
If AT = 0x0A
Resulting Parameter Value
RR = 0x0A (10 decimal)
RN = 5
Unique value based on serial number *
CD = 3
BT = 0
AT = 0
* The system requires that each remote have a unique address. The automatic address is based on the serial number and is not guaranteed unique, although the chances for a duplicate address are 1 in 16,000. No method currently exists for detecting and reassigning duplicate remote addresses.
Global Connection
The base module can connect to all remote modules (to send a broadcast message) by connecting with a DT address of 0xFFFF (hex). There will be no acknowledgements from the remote radios and each packet from the base will be sent RR times. A remote cannot send messages to a base during a global connect.
The CGP and DGP packets will be sent RR times to begin and end the global connection respectively. The connection can be terminated by CE, CB timers, DI3 or ATDC Command as any other connections.
Sleep Modes and Connections
Cyclic sleep can be used with the remote modules to conserve power. ST “Time before Sleep”
Parameter defines how long after a disconnect a remote will stay awake. A module is not allowed to enter sleep mode when it is engaged in a connection. A module will wake as defined by SM parameter and check for an RF message. If a message is detected, the module will stay awake only if the message is a connect message from the base for this module. DI3 (pin 2) wake-up can be used to wake a remote module. Usually the connection on DI3 should also be enabled so that a connection is established on wake-up.
Note: The ST (Time Before Sleep) time must be set long enough to account for the time it could take to make a connection if several remote modules get a connection before a remote’s ST times out.
Pin sleep can also be used with a remote module. A module will not be allowed into pin sleep while a connection is active. Usually the connection on DI3 (DR = 4) should also be enabled so that a connection is established on wakeup. Pin wake-up could also be used to scan for a connection at an interval not defined by the cyclic sleep modes.
I/O Passing and Connections
I/O lines can be passed between a remote and base module by enabling I/O line passing (see the
RT, DR, CD, CO, CS, BK, BO commands). When a connection is not active, the output lines on the base and remote modules will be in their default state. When a connection is established, the base and remote output line will be set to reflect the corresponding input lines.
Monitoring Connections
The DO3 pin (RX LED) can be used to show when a connection is active on both remote and base modules. This is the default condition. This line will be asserted (high) during a connection and de-asserted (low) when there is no connection.
A base module can also be set to send the “CONNECT XXXX” string (where “XXXX” is the connecting module’s MY (Source Address) parameter) anytime a connection is established. Refer to CM (Connection Message) Command.
© 2014 Digi International Inc.
49
XStream™ OEM RF Module – Product Manual v5.x00
Appendix A: Agency Certifications
FCC Certification
The XStream OEM RF Module complies with Part 15 of the FCC rules and regulations. Compliance with the labeling requirements, FCC notices and antenna usage guidelines is required.
To fulfill the FCC Certification requirements, the OEM must comply with the following FCC regulations:
The system integrator must ensure that the text on the external label provided with this device is placed on the outside of the final product (Figure A.1 for 900 MHz operations or
Figure A.2 for 2.4 GHz operations).
The XStream OEM RF Module may be used only with Approved Antennas that have been tested with this module. (Table A-01 or Table A-02)
FCC Notices:
IMPORTANT: The 9XStream (900 MHz) and 24XStream (2.4 GHz) OEM Modules have been certified by the FCC for use with other products without any further certification (as per FCC section 2.1091).
Changes or modifications not expressly approved by Digi could void the user’s authority to operate the equipment.
IMPORTANT: OEMs must test their final product to comply with unintentional radiators (FCC section
15.107 and 15.109) before declaring compliance of their final product to Part 15 of the FCC Rules.
IMPORTANT: The XStream OEM RF Modules have been certified for remote and base radio applications. If the XStream will be used for portable applications, the device must undergo SAR testing.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
•
Re-orient or relocate the receiving antenna.
•
Increase the separation between the equipment and receiver.
•
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
•
Consult the dealer or an experienced radio/TV technician for help.
© 2014 Digi International Inc.
50
XStream™ OEM RF Module – Product Manual v5.x00
OEM Labeling Requirements
Label Warning
WARNING: The Original Equipment Manufacturer (OEM) must ensure that FCC labeling requirements are met. This includes a clearly visible label on the outside of the final product enclosure that displays the contents shown in the figure below.
Figure A‐01. Required FCC Label for OEM products containing 9XStream (900 MHz) OEM RF Module
Contains FCC ID: OUR9XSTREAM
The enclosed device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference and (2) this device must accept any interference received, including interference that may cause undesired operation.
Figure A‐02. Required FCC Label for OEM products containing 24XStream (2.4 GHz) OEM RF Module
Contains FCC ID: OUR-24XSTREAM
The enclosed device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference and (2) this device must accept any interference received, including interference that may cause undesired operation.
Antenna Usage
Antenna Warning
WARNING: This device has been tested with Reverse Polarity SMA connectors with the antennas listed in Tables A.1 and A.2 of Appendix A. When integrated in OEM products, fixed antennas require installation preventing end-users from replacing them with nonapproved antennas. Antennas not listed in the tables must be tested to comply with
FCC Section 15.203 (unique antenna connectors) and Section 15.247 (emissions).
RF Exposure
WARNING: This equipment is approved only for mobile and base station transmitting devices, separation distances of (i) 20 centimeters or more for antennas with gains < 6 dBi or
(ii) 2 meters or more for antennas with gains ≥ 6 dBi should be maintained between the antenna of this device and nearby persons during operation. To ensure compliance, operation at distances closer than this is not recommended.
The preceding statement must be included as a CAUTION statement in manuals for OEM products to alert users on FCC RF Exposure compliance.
Digi Modules are pre-FCC approved for use in fixed base station and mobile applications. As long as the antenna is mounted at least 20 cm (8 in) from nearby persons, the application is considered a mobile application. If the antenna will be mounted closer than 20 cm to nearby persons, then the application is considered “portable” and requires an additional test performed on the final product. This test is called the Specific Absorption Rate (SAR) testing and measures the emissions from the module and how they affect the person.
Over 100 additional antennas have been tested and are approved for use with Digi 900
MHz Modules (including “Mag Mount”, “Dome”, “Multi-path” and “Panel” antennas). Because of the large number of approved antennas, Digi requests that you send specific information about an antenna you would like to use with the module and Digi will evaluate whether the antenna is covered under the FCC certification.
© 2014 Digi International Inc.
51
XStream™ OEM RF Module – Product Manual v5.x00
FCC-Approved Antennas
Manufacturer
Digi
Digi
Digi
Digi
Digi
Digi
Digi
Digi
Digi
*
*
*
*
*
*
*
Table A‐01. Antennas approved for use with 9XStream (900 MHz) OEM RF Modules.
Part Number
*
*
A09-Y8
*
*
A09-Y11 (FCC pending)
A09-F2
A09-F5
A09-F8
*
*
A09-M7
A09-H
A09-HBMM-P5I
A09-QBMM-P5I
*
Type
Yagi
Yagi
Yagi
Yagi
Yagi
Yagi
Omni Direct.
Omni Direct.
Omni Direct.
Omni Direct.
Omni Direct.
Omni Direct.
1/2 wave antenna
1/2 wave antenna
1/4 wave antenna
1/4 wave integrated wire antenna
Gain
6.2 dBi
7.2 dBi
8.2 dBi
9.2 dBi
10.2 dBi
11.2 dBi
2.2 dBi
5.2 dBi
8.2 dBi
9.2 dBi
7.2 dBi
7.2 dBi
2.1 dBi
2.1 dBi
1.9 dBi
1.9 dBi
Application
Fixed/Mobile **
Fixed/Mobile **
Fixed/Mobile **
Fixed/Mobile **
Fixed/Mobile **
Fixed/Mobile **
Fixed **
Fixed **
Fixed **
Fixed **
Fixed **
Fixed **
Fixed/Mobile **
Fixed/Mobile **
Fixed/Mobile **
Fixed/Mobile **
Manufacturer
Digi
Digi
Digi
Digi
Digi
Digi
Digi
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
Table A‐02. Antennas approved for use with 24XStream (2.4 GHz) OEM RF Modules.
Part Number
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
A24-P8
A24-P13
*
*
*
A24-P19
A24-HABMM-P6I
A24-HBMM-P6I
A24-HABSM
A24-QABMM-P6I
A24-Q1
*
Type
Yagi
Yagi
Yagi
Yagi
Yagi
Yagi
Yagi
Yagi
Yagi
Omni Direct
Omni Direct
Omni Direct
Omni Direct
Omni Direct
Omni Direct
Omni Direct
Omni Direct
Omni Direct
Panel
Panel
Panel
Panel
Panel
Panel
Dipole
Dipole
Dipole
Monopole
Monopole
Monopole
Gain
6 dBi
8.8 dBi
9 dBi
10 dBi
11 dBi
12 dBi
12.5 dBi
13.5 dBi
15 dBi
2.1 dBi
3 dBi
13 dBi
14 dBi
15 dBi
16 dBi
19 dBi
2.1 dBi
2.1 dBi
2.1 dBi
5 dBi
7.2 dBi
8 dBi
9.5 dBi
10 dBi
12 dBi
15 dBi
8.5 dBi
1.9 dBi
1.9 dBi
1.9 dBi
Application
Fixed **
Fixed **
Fixed **
Fixed **
Fixed **
Fixed **
Fixed **
Fixed **
Fixed **
Fixed/Mobile **
Fixed/Mobile **
Fixed/Mobile **
Fixed **
Fixed **
Fixed **
Fixed **
Fixed **
Fixed **
Fixed **
Fixed **
Fixed **
Fixed **
Fixed **
Fixed **
Fixed/Mobile **
Fixed/Mobile **
Fixed/Mobile **
Fixed/Mobile **
Fixed/Mobile **
Fixed/Mobile **
* FCC‐approved antennas not inventoried by Digi – Contact Digi (866) 765‐9885 for information.
** Can be approved for portable applications if integrator gains approval through SAR testing
© 2014 Digi International Inc.
Min. Separation Distance
20 cm
20 cm
20 cm
20 cm
20 cm
1 cm
1 cm
20 cm
20 cm
20 cm
20 cm
20 cm
20 cm
20 cm
20 cm
1 cm
Min. Separation Distance
2 m
2 m
2 m
2 m
2 m
2 m
2 m
2 m
2 m
20 cm
20 cm
2 m
2 m
2 m
2 m
2 m
20 cm
20 cm
20 cm
20 cm
2 m
2 m
2 m
2 m
2 m
2 m
2 m
20 cm
20 cm
20cm
52
XStream™ OEM RF Module – Product Manual v5.x00
IC (Industry Canada) Certification
Labeling requirements for Industry Canada are similar to those of the FCC. A clearly visible label on the outside of the final product enclosure must display the following text:
Contains Model 9XStream Radio (900 MHz), IC: 4214A-9XSTREAM
Contains Model 24XStream Radio (2.4 GHz), IC: 4214A 12008
Integrator is responsible for its product to comply with IC ICES-003 and FCC Part 15, SuB-0 B
- Unintentional Radiators. ICES-003 is the same as FCC Part 15 SuB-0 B and Industry Canada accepts FCC test report or CISPR 22 test report for compliance with ICES-003.
© 2014 Digi International Inc.
53
XStream™ OEM RF Module – Product Manual v5.x00
Appendix B: Development Guide
XStream OEM Development Kit Contents
The Development Kit includes all the hardware and software needed for a robust wireless link:
Table B‐01. XStream Development Kit Contents
Item
Quick Start Guide
CD
XStream OEM RF Module 1
XStream OEM RF Module 1
1
1
Digi Interface Board
Antenna
2
1
Serial Loopback Adapter 1
NULL Modem Adapter
(male-to-male)
Qty. Description
1
1
Part Number
Familiarizes users with some of the module’s most important functions. MD0016
Contains documentation, software and tools needed for RF operation. MD0030
Long Range OEM RF Module w/ RPSMA Connector
Long Range OEM RF Module w/ attached wire antenna varies varies
Enables communication to RS-232/485/422 devices
900 MHz RPSMA, 6" Half-Wave, dipole, articulating
Connects to the female RS-232 (DB-9) serial connector of the Digi
Interface Board and can be used to configure the module to function as a repeater (for range testing)
Connects to the female RS-232 (DB-9) serial connector of the Digi
Interface Board and can be used to connect the module to another
DCE (female DB9) device
Used to bypass radios to verify serial cabling is functioning properly
XIB-R
A09-HASM-675
JD2D3-CDL-A
JD2D2-CDN-A
JD3D3-CDN-A
NULL Modem Adapter
(female-to-female)
Male DB-9 to
RJ-45 Adapter
Female DB-9 to
RJ-45 Adapter
Power Adapter
RS-232 Cable (6’)
1
1
2
2
Facilitates adapting the DB-9 Connector of the Digi Interface
Board to a CAT5 cable (male DB9 to female RJ45)
Facilitates adapting the DB-9 Connector of the Digi Interface
Board to a CAT5 cable (female DB9 to female RJ45)
JE1D2-CDA-A
JE1D3-CDA-A
Allows Interface Board to be powered by a 110 Volt AC power supply JP4P2-9V10-6F
Connects interface board to devices having an RS-232 serial port JD2D3-CDS-6F
Interfacing Hardware
Digi developed proprietary interface boards to facilitate the connection between XStream
OEM RF Modules and serial devices. Digi has developed an interface board that supports the RS-
232/485/422 protocols (Digi part number: XIB-R).
© 2014 Digi International Inc.
54
XStream™ OEM RF Module – Product Manual v5.x00
The following section illustrates properties of the Digi XIB-R Interface Board. The Digi Interface board provides means for connecting the XStream Module to any node that has an available RS-
232 or RS-485/422 connection. Since the module requires signals to enter at CMOS voltages, one of the main functions of the interface board is to convert signals between CMOS and RS-232 levels.
© 2014 Digi International Inc.
55
XStream™ OEM RF Module – Product Manual v5.x00
Digi RS-232/485 Interface Board
Figure B‐01. Front
View
B‐01a.
Power
Switch
B‐01b.
LEDs
B‐01c.
Serial Port
B‐0d.
Power
Connector
B-01a. Power Switch
Move the Power Switch to the on (up) position to power the
Interface Board. DIP Switch (B.2a) settings are only read during a power-up sequence.
B-01b. LEDs
The LED indicators visualize diagnostic status information. The module’s status is represented as follows:
Yellow (top LED) = Serial Data Out (to host)
Green (middle) = Serial Data In (from host)
Red (bottom) = Power/TX Indicator (Red light is on when powered, off briefly during RF transmission)
B-01c. Serial Port
Standard female DB-9 (RS-232) DCE connector – This connector can be also used for RS-485 and RS-422 connections.
B-01d. Power Connector
7-18 VDC Power Connector (Center positive, 5.5/2.1mm) – Power can also be supplied through Pin 9 of the DB-9 Serial Port.
Figure B‐02. Back View
B‐02a.
DIP Switch
B‐02b.
Config Switch
B-02a. DIP Switch
The DIP Switch automatically configures the XStream OEM RF
Module to operate in different modes. Each time the module assembly (interface board + the RF Module) is powered-on, intelligence on the XIB-R interface board programs the module according to the positions of the DIP Switch. (See figure below for DIP Switch settings)
Note: In cases where AT Commands should not be sent each time the module assembly is powered-on, the processor must be disabled by populating J7 on the interface board.
B-02b. Config (Configuration) Switch
The Configuration Switch provides an alternate way to enter “AT
Command Mode”. To enter “AT Command Mode” at the module’s default baud rate, hold the Configuration Switch down while powering on the module using the Power Switch (B-01a).
Figure B‐03. Digi XIB‐R (RS‐232/485) Interface Board DIP Switch Settings
Refer to table in the
Automatic DIP Switch
Configurations section (next page) for more information regarding configurations triggered by the DIP Switch.
© 2014 Digi International Inc.
56
XStream™ OEM RF Module – Product Manual v5.x00
Automatic DIP Switch Configurations
Each time the module assembly (XStream Module mounted to an XIB-R Interface Board) is powered on, intelligence on the Digi Interface Board sends AT Commands that program the module based on positions of the DIP Switch. Automatic configurations that take place during the power-on sequence affect module parameter values as shown below.
To avoid overwriting previously stored custom configurations (due to the automatic configurations that take place each time the module assembly is powered on), it is necessary to disable a processor located on the XIB-R interface board. To disable the processor, populate J7 of the XIB-R Interface Board. By default, J7 jumper is not populated.
Table B‐02. Module Power‐up Options (J7 jumper and Config Switch)
Condition Behavior
If J7 is populated
If Config Switch is pressed
Processor is disabled and AT Commands are not sent to the Module.
Processor is disabled and Module enters into AT Command Mode.
If J7 is NOT populated and Config Switch is NOT pressed
Execute logic as shown in table below.
Table B‐03. AT Commands Sent as result of DIP Switch Settings (SW = DIP Switch)
Condition Behavior
Restore Default Parameter Values of the Module
If SW1 and SW2 are ON (up)
AT Commands sent: ATRE (Restore Defaults) Command
ATWR (Write) Command
Serial Interfacing Options
If SW1 is ON (up)
If SW1 is OFF (down)
AT Commands sent: ATCS 0 (RS-232 Operation: CTS function for CTS line,
DB-9 pin 8)
ATCD 2 (DO3 - RX LED = low)
AT Commands sent: ATCS 3 (RS-485 or RS-422 Operation)
ATCD 2 (DO3 - RX LED = low)
Parity Options
If SW5 and SW6 are OFF (down) AT Commands sent: ATNB 0 (parity = none)
If SW5 is OFF (down) and SW6 is ON (up) AT Commands sent: ATNB 1 (parity = even)
If SW5 is ON (up) and SW6 is OFF (down) AT Commands sent: ATNB 2 (parity = odd)
If SW5 is ON (up) and SW6 is ON (up) AT Commands sent: ATNB 5 (parity = 9th bit data over-the-air)
Exit AT Command Mode
Always AT Commands sent: ATCN (Exit AT Command Mode)
© 2014 Digi International Inc.
57
XStream™ OEM RF Module – Product Manual v5.x00
Adapters
The XStream Development Kit comes with several adapters that support the following functions:
•
Performing Range Tests
•
Testing Cables
•
Connecting to other RS-232 DCE and DTE devices
•
Connecting to terminal blocks or RJ-45 (for RS-485/422 devices)
NULL Modem Adapter (male-to-male)
Part Number: JD2D2-CDN-A (Black, DB-9 M-M) The male-to-male NULL modem adapter is used to connect two DCE devices. A DCE device connects with a straight-through cable to the male serial port of a computer (DTE).
Figure B‐04. Male NULL modem adapter and pinouts
Figure B‐05. Example of a module assembly (DCE Device) connecting to another DCE device)
NULL Modem Adapter (female-to-female)
Part Number: JD3D3-CDN-A (Gray, DB-9 F-F) The female-to-female NULL modem adapter is used to verify serial cabling is functioning properly. To test cables, insert the female-to-female
NULL modem adapter in place of a pair of module assemblies (XIB-R-R interface board +
XStream Module) and test the connection without radio modules in the connection.
Figure B‐06. Female NULL modem adapter and pinouts
Serial Loopback Adapter
For use in RS‐485/422 systems: DB‐9 to RJ‐45 adapters are documented on p45.
Part Number: JD2D3-CDL-A (Red, DB-9 M-F) The serial loopback adapter is used for range testing. During a range test, the serial loopback adapter configures the module assembly to function as a repeater by looping serial data back into the radio for retransmission.
Figure B‐07. Serial loopback adapter and pinouts
© 2014 Digi International Inc.
58
XStream™ OEM RF Module – Product Manual v5.x00
Antennas
(Refer to Appendix A for a list of FCC-Approved Antennas)
Factors that determine wireless link range:
•
Ambient RF noise (interference)
•
Line-of-sight obstructions
•
Transmit power
•
Receive sensitivity
•
Antenna configuration
XStream Antenna Connector Options
To comply with the FCC rules and obtain a “modular” certification, it is required that XStream
Modules utilize a “non standard” connector. This is to ensure the modules are used only with approved antennas. The XStream Modules have two connector options:
•
RPSMA
•
MMCX
Alternatively, the XStream Module can be order with an attached wire antenna.
RPSMA
The Reverse Polarity SMA (RPSMA) connector uses the same body as a regular SMA connector. In order to be a “non standard” connector, the gender of the center conductor is changed. The female RPSMA actually has a male center conductor.
MMCX
The Micro-Miniature Connector (MMCX) is a good solution for high volume, price-sensitive applications. The small size and snap on connection make it suitable for attaching an external mounted antenna to a module inside an enclosure.
Antenna Cables
RF cables are typically used to connect a radio installed in a cabinet to an antenna mounted externally. As a general rule, it is best to keep the RF cable as short as possible. All cables promote signal loss which is usually measured in dB loss per 100 ft. Digi provides LMR-
195 rated cables. Common cables and dB losses are included in this table:
Table B‐04. Potential Signal Strength Loss due to Antenna Cable Length
Cable
Type
Loss at 900 MHz per 100’
(loss per 100m)
Loss at 2.4 GHz per 100’
(loss per 100m)
Diameter
RG-58
RG-174
14.5 dB (47.4 dB)
25.9 dB (85.0 dB)
25.3 dB (83.2 dB)
44.4 dB (145.8 dB)
0.20” (4.95 mm)
0.10” (2.54 mm)
RG-316
LMR-195
LMR-240
24.7 dB (81.0 dB)
11.1 dB (36.5 dB)
7.6 dB (24.8 dB)
42.4 dB (139.0 dB)
19.0 dB (62.4 dB)
12.9 dB (42.4 dB)
0.10” (2.59 mm)
0.20” (4.95 mm)
0.24“ (6.10 mm)
LMR-600 2.5 dB (8.2 dB) 4.4 dB (14.5 dB) 0.59” (15.0 mm)
© 2014 Digi International Inc.
59
XStream™ OEM RF Module – Product Manual v5.x00
Interfacing Protocols
The Module Assembly supports the following interfacing protocols:
•
RS-232
•
RS-485 (2-wire) Half-Duplex
•
RS-485 (4-wire) and RS-422
RS-232 Operation
DIP Switch Settings and Serial Port Connections
Figure B‐08. Figure B‐09
RS‐232 DIP Switch Settings Pins used on the female RS‐232 (DB‐9)
Serial Connector
DIP Switch settings are read and applied only while powering‐on.
Table B‐05. RS‐232 Signals and their implementations on the XStream Module Assembly
(Low‐asserted signals are distinguished by horizontal line over pin name.)
DB-9 Pin
1
2
5
6
3
4
RS-232 Name
DCD
RXD
TXD
DTR
GND
DSR
AT Command Reference*
DO3
DO
DI
DI3
-
DO3
Description
Data-Carrier-Detect
Received Data
Transmitted Data
Data-Terminal-Ready
Ground Signal
Data-Set-Ready
Implementation
Connected to DSR (pin6)
Serial data exiting the Module Assembly
(to host)
Serial data entering into the Module
Assembly (from host)
Can enable POWER-DOWN on the
Module Assembly
Ground
Connected to DCD (pin1)
7 RTS/CMD DI2 Request-to-Send
Provides RTS flow control or enables
“Command Mode” on the Module
8 CTS DO2 Clear-to-Send Provides CTS flow control
9 DI - Ring Indicator
Optional power input that is connected internally to the positive lead of the front power connector
* The AT Command Reference provides as associative tag when using the AT commands to program the
Module. “DI” stands for Data Input and “DO” for Data Output.
© 2014 Digi International Inc. 60
XStream™ OEM RF Module – Product Manual v5.x00
Wiring Diagram: RS-232 DTE Device to a DCE Module Assembly
Figure B‐10. RS‐232 DTE (male connector) device wired to an XStream Module Assembly (female
connector)
Wiring Diagram: DCE Module Assembly to an RS-232 DCE Device
Figure B‐11. XStream Module Assembly (female connector) wired to an RS‐232 DTE (male connector)
device
Sample Wireless Connection: DTE DCE -------- DCE DCE
Figure B‐12 Typical wireless connection used for serial communications between DTE and DCE devices
© 2014 Digi International Inc. 61
XStream™ OEM RF Module – Product Manual v5.x00
RS-485 (2-wire) Operation
DIP Switch Settings and Serial Port Connections
Figure B‐13. Figure B‐14.
RS‐485 (2‐wire) Half‐Duplex Pins used on the female RS‐232 (DB‐9)
DIP Switch Settings Serial Connector
Figure B‐15
RS‐485 (2‐wire) with Termination (optional)
Termination is the 120 Ω resistor between T+ and T-.
DIP Switch settings are read and applied only while powering-on.
Note: Refer to Figure B-022 and Figure B-023 (p45) for RJ-45 connector pin designations used in
RS-485/422 environments.
Table B‐06. RS‐485 (2‐wire half‐duplex) Signals and their implementations on the XStream Module
Assembly
Description DB-9 Pin RS-485 Name
2 T/R- (TRA)
5
8
9
1, 3, 4, 6, 7
GND
T/R+ (TRB)
PWR
Negative Data Line
Ground Signal
Positive Data Line
Power
Implementation
Transmit serial data to and from the
XStream Module Assembly
Ground
Optional power input that is connected internally to the front power connector not used
Transmit serial data to and from the
XStream Module Assembly
Wiring Diagram: RS-485 (2-wire) Half-Duplex
Figure B‐16. XStream Module Assembly in an RS‐485 (2‐wire) half‐duplex environment
© 2014 Digi International Inc.
62
XStream™ OEM RF Module – Product Manual v5.x00
RS-485 (4-wire) and RS-422 Operation
DIP Switch Settings and Serial Port Connections
Figure B‐17 Figure B‐18
RS‐485 (4‐wire) and RS‐422 Pins used on the female RS‐232 (DB‐9)
DIP Switch Settings Serial Connector
Figure B‐19
RS‐485 (4‐wire) and RS‐422 with Termination (optional)
Termination is the 120 Ω resistor between T+ and T-.
DIP Switch settings are read and applied only while powering-on.
Table B‐07. RS‐485/422 (4‐wire) Signals and their implementations with the Module Assembly
DB-9 Pin
RS-485/422
Name
Description Implementation
2
3
5
T- (TA)
R- (RA)
GND
Transmit Negative
Data Line
Receive Negative
Data Line
Signal Ground
Serial data sent from the XStream Module Assembly
Serial data received by the XStream Module Assembly
Ground
7
8
R+ (RB)
T+ (TB)
Receive Positive
Data Line
Transmit Positive
Data Line
Serial data received by the XStream Module Assembly
Serial data sent from the XStream Module Assembly
9
1, 4, 6
PWR Power
Optional power input that is connected internally to the front power connector not used
Wiring Diagram: RS-485 (4-wire) Half-Duplex
Figure B‐20. XStream Module Assembly in an RS‐485 (4‐wire) environment
© 2014 Digi International Inc.
63
XStream™ OEM RF Module – Product Manual v5.x00
Wiring Diagram: RS-422
Figure B‐21. XStream Module Assembly in an RS‐485 (4‐wire) environment
RS-485/422 Connection Guidelines
The RS-485/422 protocol provides a solution for wired communications that can tolerate high noise and push signals over long cable lengths. RS-485/422 signals can communicate as far as
4000 feet (1200 m). RS-232 signals are suitable for cable distances up to 100 feet (30.5 m).
RS-485 offers multi-drop capability in which up to 32 nodes can be connected. The RS-422 protocol is used for point-to-point communications.
Suggestions for integrating the XStream Module with the RS-485/422 protocol:
When using Ethernet twisted pair cabling: Select wires so that T+ and T- are connected to each wire in a twisted pair. Likewise, select wires so that R+ and R- are connected to a twisted pair. (For example, tie the green and white/green wires to T+ and T-.)
For straight-through Ethernet cable (not cross-over cable) – The following wiring pattern works well: Pin3 to T+, Pin4 to R+, Pin5 to R-, Pin6 to T-
Note that the connecting cable only requires 4 wires (even though there are 8 wires).
When using phone cabling (RJ-11) – Pin2 in the cable maps to Pin3 on opposite end of cable and Pin1 maps to Pin4 respectively.
Figure B‐22 Male (yellow) DB‐9 to RJ‐45 Adapters
Figure B‐23. Female (green) DB‐9 to RJ‐45 Adapters
© 2014 Digi International Inc.
64
XStream™ OEM RF Module – Product Manual v5.x00
XCTU Software
Using the XCTU Software
XCTU is Digi-provided software used to interface with and configure XStream OEM RF
Modules. The software application is organized into the following four tabs:
•
PC Settings tab - Setup PC serial ports to interface with an XStream Module assembly
•
Range Test tab – Test XStream Module's range and monitor packets sent and received
•
Terminal tab – Set and read XStream Module parameters using AT Commands
•
Modem Configuration tab – Set and read XStream Module parameters
Figure B‐24 X‐CTU User Interface (PC Settings, Range Test, Terminal and Modem Configuration tabs)
Install XCTU software
Navigate to: www.digi.com/support. Then select “XCTU” under the product list. Select the appropriate driver to install the XCTU software.
Setup
To use the XCTU software, a module assembly (XStream Module mounted to a Digi XIB- R-R
Interface Board) must be connected to the serial port of a PC. The data rate and parity settings of the serial port (“PC Settings” tab) must match those of the module (BD (Baud Rate) and NB
(Parity) Commands).
Serial Communications Software
A terminal program is built into the XCTU Software. Other terminal programs such as
“HyperTerminal” can also be used. When issuing AT Commands through a terminal program interface, use the following syntax:
Figure B‐25 Syntax for sending AT Commands:
Note: To read a parameter value stored in a register, leave the parameter field blank.
The example above issues DT Command to change destination address of the module to “0x1F”.
To save the new value to the module’s non-volatile (long term) memory, issue WR (Write)
Command after modifying parameters
© 2014 Digi International Inc.
65
XStream™ OEM RF Module – Product Manual v5.x00
Appendix C: Additional Information
1-Year Warranty
XStream OEM RF Modules from Digi International Inc. (the ʺProductʺ) are warranted against defects in materials and workmanship under normal use, for a period of 1‐year from the date of purchase. In the event of a product failure due to materials or workmanship, Digi will repair or replace the defective product. For warranty service, return the defective product to Digi, shipping prepaid, for prompt repair or replacement.
The foregoing sets forth the full extent of Digiʹs warranties regarding the Product. Repair or replacement at Digiʹs option is the exclusive remedy. THIS WARRANTY IS GIVEN IN LIEU OF ALL
OTHER WARRANTIES, EXPRESS OR IMPLIED, AND DIGI SPECIFICALLY DISCLAIMS ALL
WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. IN NO
EVENT SHALL DIGI, ITS SUPPLIERS OR LICENSORS BE LIABLE FOR DAMAGES IN EXCESS OF
THE PURCHASE PRICE OF THE PRODUCT, FOR ANY LOSS OF USE, LOSS OF TIME,
INCONVENIENCE, COMMERCIAL LOSS, LOST PROFITS OR SAVINGS, OR OTHER
INCIDENTAL, SPECIAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE OR
INABILITY TO USE THE PRODUCT, TO THE FULL EXTENT SUCH MAY BE DISCLAIMED BY
LAW. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR
CONSEQUENTIAL DAMAGES. THEREFOR, THE FOREGOING EXCLUSIONS MAY NOT APPLY
IN ALL CASES. This warranty provides specific legal rights. Other rights which vary from state to state may also apply.
Ordering Information
Figure C‐01 Digi OEM RF Module Part Numbers Key
© 2014 Digi International Inc.
66
XStream™ OEM RF Module – Product Manual v5.x00
Contact Digi
If you need assistance, contact technical support:
Documentation: www.digi.com/support/
Technical Support: Phone
Online
(866) 765-9885 toll-free U.S. and Canada
(801) 765-9885 Worldwide
8:00 am – 5:00 pm (U.S. Mountain Time) www.digi.com/support/eservice
© 2014 Digi International Inc.
67
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 11 DI (Data In) Buffer and Flow Control
- 11 DO (Data Out) Buffer and Flow Control
- 13 RF Data Packet
- 17 AT Commands
- 40 Theory of Operation
- 41 Repeater Network Configuration
- 43 Use Case - Broadcast Repeater Network
- 44 Acknowledged Mode Connection Sequence
- 46 Theory of Operation
- 48 Configuration
- 49 Global Connection
- 49 Sleep Modes and Connections
- 49 I/O Passing and Connections
- 49 Monitoring Connections
- 51 Label Warning
- 58 NULL Modem Adapter (male-to-male)
- 58 NULL Modem Adapter (female-to-female)
- 58 Serial Loopback Adapter
- 59 Antenna Cables
- 60 Table B‐05. RS‐232 Signals and their implementations on the XStream Module Assembly