- Computers & electronics
- Networking
- Network media converters
- Allied Telesis
- AT-MC103LH
- Installation Guide
advertisement
PN 613-10771-00 Rev F
AT-MC101XL
AT-MC102XL
AT-MC103XL
AT-MC103LH
AT-MC103SC/FSx
AT-MC103ST/FSx
Fast Ethernet Media Converters
Version 3
Installation Guide
Copyright
2003 Allied Telesyn, Inc.
960 Stewart Drive Suite B, Sunnyvale CA 94086 USA
All rights reserved. No part of this publication may be reproduced without prior written permission from Allied Telesyn, Inc.
Ethernet is a registered trademark of Xerox Corporation. All other product names, company names, logos or other designations mentioned herein are trademarks or registered trademarks of their respective owners.
Allied Telesyn, Inc. reserves the right to make changes in specifications and other information contained in this document without prior written notice. The information provided herein is subject to change without notice. In no event shall Allied Telesyn,
Inc. be liable for any incidental, special, indirect, or consequential damages whatsoever, including but not limited to lost profits, arising out of or related to this manual or the information contained herein, even if Allied Telesyn, Inc. has been advised of, known, or should have known, the possibility of such damages.
Electrical Safety and Emission Compliance
Standards: This product meets the following standards.
U.S. Federal Communications Commission
Declaration Of Conformity
Manufacture Name:
Manufacture Address:
Manufacture Telephone:
Declares that the Product:
Model Numbers:
Allied Telesyn, Inc.
960 Stewart Drive, Suite B
Sunnyvale, CA 94086 USA
408-730-0950
Fast Ethernet Media Converters
AT-MC101XL, AT-MC102XL,
AT-MC103XL, AT-MC103LH,
AT-MC103SC/FS3,
AT-MC103ST/FS3,
AT-MC103SC/FS4,
AT-MC103ST/FS4
This product complies with FCC Part 15B, Class B Limits:
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device must not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Radiated Energy
Note: This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with instructions, may cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on; the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and the receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
Changes and modifications not expressly approved by the manufacturer or registrant of this equipment can void your authority to operate this equipment under Federal Communications Commission rules.
Warning: This product requires only Category 3, 4, or 5 shielded twistedpair cable for all 10 Mbps RJ-45 connections, and Category 5 shielded twisted-pair for all 100 Mbps RJ-45 connections to comply with Class B emission limits. If not used with shielded cables, this product may cause radio interference in which case the user may be required to take adequate measures to reduce interference levels.
iii
Electrical Safety and Emission Compliance
Industry Canada
This Class B digital apparatus meets all requirements of the Canadian
Interference-Causing Equipment Regulations.
Cet appareil numérique de la classe B respecte toutes les exigences du
Règlement sur le matériel brouilleur du Canada.
RFI Emission
Immunity
EN55022 Class B
!
1
EN50082-1 1997
!
2
Warning: This product requires shielded cables to comply with emission and immunity standards. If it is used with unshielded cables, the user may be required to take measures to correct the interference problem at their own expense.
!
3
Electrical Safety
Laser
EN60950 (TUV), UL1950, ( c
UL us
)
!
4
EN60825
!
5
Power to the hub must be sourced only from the adapter.
!
10
USA/Canada
Use a UL Listed/CSA Certified AC adapter of DC 12V, 500mA.
Europe - EU
Use TÜV licensed AC adapter of DC 12V, 500mA.
UK
Use a UK Safety Approved AC adapter of DC 12V, minimum 500mA.
Important: Appendix A contains translated safety statements for installing this equipment. When you see the !, go to Appendix A for the translated safety statement in your language.
Wichtig: Anhang A enthält übersetzte Sicherheitshinweise für die
Installation dieses Geräts. Wenn Sie ! sehen, schlagen Sie in Anhang A den
übersetzten Sicherheitshinweis in Ihrer Sprache nach.
Vigtigt: Tillæg A indeholder oversatte sikkerhedsadvarsler, der vedrører installation af dette udstyr. Når De ser symbolet !, skal De slå op i tillæg A og finde de oversatte sikkerhedsadvarsler i Deres eget sprog.
Belangrijk: Appendix A bevat vertaalde veiligheidsopmerkingen voor het installeren van deze apparatuur. Wanneer u de ! ziet, raadpleeg Appendix
A voor vertaalde veiligheidsinstructies in uw taal.
Important: L'annexe A contient les instructions de sécurité relatives à l'installation de cet équipement. Lorsque vous voyez le symbole !, reportezvous à l'annexe A pour consulter la traduction de ces instructions dans votre langue.
Tärkeää: Liite A sisältää tämän laitteen asentamiseen liittyvät käännetyt turvaohjeet. Kun näet !-symbolin, katso käännettyä turvaohjetta liitteestä
A.
Importante: l’Appendice A contiene avvisi di sicurezza tradotti per l’installazione di questa apparecchiatura. Il simbolo !, indica di consultare l’Appendice A per l’avviso di sicurezza nella propria lingua.
Viktig: Tillegg A inneholder oversatt sikkerhetsinformasjon for installering av dette utstyret. Når du ser !, åpner du til Tillegg A for å finne den oversatte sikkerhetsinformasjonen på ønsket språk. iv
AT-MC100 Series Installation Guide
Importante: O Anexo A contém advertências de segurança traduzidas para instalar este equipamento. Quando vir o símbolo !, leia a advertência de segurança traduzida no seu idioma no Anexo A.
Importante: El Apéndice A contiene mensajes de seguridad traducidos para la instalación de este equipo. Cuando vea el símbolo !, vaya al Apéndice A para ver el mensaje de seguridad traducido a su idioma.
Obs! Bilaga A innehåller översatta säkerhetsmeddelanden avseende installationen av denna utrustning. När du ser !, skall du gå till Bilaga A för att läsa det översatta säkerhetsmeddelandet på ditt språk.
v
Table of Contents
Electrical Safety and Emission Compliance............................................iii
Contacting Allied Telesyn Technical Support................................................... x
Link Test/MissingLink Button ................................................................... 4
External AC/DC Power Adapter................................................................. 6
Installing the Media Converter ................................................................... 9
vii
Translated Electrical Safety and Emission Information..................... 23
viii
Welcome to Allied Telesyn
This guide contains instructions on how to install an AT-MC100 Series Fast
Ethernet Media Converter.
Where to Find Web-based Guides
The Allied Telesyn web site at www.alliedtelesyn.com offers you an easy way to access the most recent documentation, software, and technical information for all of our products. For product guides, select “Support &
Services” from our web site.
Document Conventions
This guide uses the following conventions:
Note
Notes provide additional information.
Caution
Cautions indicate that performing or omitting a specific action may result in equipment damage or loss of data.
Warning
Warnings indicate that performing or omitting a specific action may result in bodily injury.
ix
Welcome to Allied Telesyn
Contacting Allied Telesyn Technical Support
You can contact Allied Telesyn technical support online or by telephone or e-mail.
Online Support
You can request technical support online by accessing the Knowledge Base at
http:\\kb.alliedtelesyn.com. You can use the Knowledge Base to submit questions to our technical support staff and review answers to previously asked questions.
Telephone Support
For technical support by telephone, contact Allied Telesyn at one of the following locations:
Americas
United States, Canada, Mexico,
Central America, South America
Tel: 1 (800) 428-4835
Germany
Switzerland, Austria, Eastern Europe
Tel: (+49) 30-435-900-126
Asia
Singapore, Taiwan, Thailand,
Malaysia, Indonesia, Korea,
Philippines, China, India, Hong Kong
Tel: (+65) 3815-612
Italy
Spain, Portugal, Greece, Turkey, Israel
Tel: (+39) 02-41-30-41
Australia
Tel: 1 (800) 000-880
France
Belgium, Luxembourg, The
Netherlands, Middle East, Africa
Tel: (+33) 0-1-60-92-15-25
Japan
Tel: (+81) 3-3443-5640
United Kingdom
Denmark, Norway, Sweden, Finland
Tel: (+0044) 1235-442500
E-mail Support
Latin America, Mexico, Puerto Rico, Caribbean, and Virgin Islands [email protected]
Europe [email protected]
x
AT-MC100 Series Installation Guide
Returning Products
Products for return or repair must first be assigned a Return Materials
Authorization (RMA) number. A product sent to Allied Telesyn without a
RMA number will be returned to the sender at the sender’s expense.
To obtain an RMA number, contact Allied Telesyn’s Technical Support at one of the following locations:
North America
Toll-free: 1-800-762-1664
Fax: 1-425-806-1050
Latin America, the Caribbean,
Virgin Islands
Tel: international code + 425-481-3852
Fax: international code + 425-481-3895
Mexico
Toll-free: 800-424-5012, ext 3852
Fax: international code+425-481-3895
Australia
Toll-free: 1-800-000-880
Fax: +61-2-9438-4966
Europe, Africa, and the Middle
East
Tel: +44-1793-501401
Fax: +44-1793-431099
Puerto Rico
Tel: 1-800-424-5012, ext 3852 or
1-800-424-4284, ext 3852
Asia and South America
Tel: +65-381-5612
Fax: +65-383-3830
New Zealand
Toll-free: 0800-45-5782
Management Software Updates
New releases of management software for our managed products can be downloaded from our web site at www.alliedtelesyn.com or our FTP server at ftp.alliedtelesyn.com. To use the FTP server, enter ‘anonymous’ for the user name and your e-mail address for the password.
For Sales or Corporate Information
You can contact Allied Telesyn for sales or corporate information at the location below:
Allied Telesyn, Inc.
19800 North Creek Parkway, Suite 200
Bothell, WA 98011
Tel: 1 (425) 487-8880
Fax: 1 (425) 489-9191 xi
Welcome to Allied Telesyn
Tell Us What You Think
If you have any comments or suggestions on how we might improve this or other Allied Telesyn documents, please fill out the General Enquiry Form online. This form can be accessed by selecting “Contact Us” from
www.alliedtelesyn.com.
xii
Chapter 1
Overview
The AT-MC100 Series Fast Ethernet Media Converters include the following models:
❑ AT-MC101XL
❑ AT-MC102XL
❑ AT-MC103XL
❑ AT-MC103LH
❑ AT-MC103SC/FS3
❑ AT-MC103ST/FS3
❑ AT-MC103SC/FS4
❑ AT-MC103ST/FS4
The AT-MC100 Series Fast Ethernet Media Converters are designed to extend the distance of your network by interconnecting LAN devices that are physically separated by large distances. Each media converter features a
100Base-TX twisted pair port and a 100Base-FX fiber optic port. The twisted pair port has an RJ-45 connector and a maximum operating distance of 100 meters (328 feet). The fiber optic port has an ST or SC connector and a maximum operating distance of 2 kilometers (1.2 miles) to 100 kilometers (62 miles), depending on the model. These units operate at 100 Mbps and feature half- and full-duplex operation.
The media converters can be installed on a desktop or in an AT-MCR12 chassis. The AT-MC100 Series Media Converters are easy to install and do not
require any software configuration or management. Figure 1 shows an
example of an AT-MC100 Series Media Converter.
CLASS 1
LASER PRODUCT
DO NOT STARE
INTO BEAM
M/L
ON
TX RX
100Base-FX 100Base-TX
LNK
A/N ON MDI
LNK TST
ACT A/N OFF MDI-X
SINGLE MODE
MC103SC/FS3 FAST ETHERNET MEDIA CONVERTER
Figure 1 AT-MC103SC/FS3 Model
FDX
LNK
PWR
ACT M/L ON
1
Overview
Table 1 lists the maximum operating distances for the media converters.
Table 1 Maximum Operating Distances
Model Type of Connector Maximum Operating Distance
100Base-FX
1
100Base-TX 100Base-FX 100Base-TX
AT-MC101XL
AT-MC102XL
AT-MC103XL
AT-MC103LH
AT-MC103SC/FS3
AT-MC103ST/FS3
ST
SC
SC
SC
SC
ST
AT-MC103SC/FS4 SC
AT-MC103ST/FS4 ST
RJ-45
RJ-45
RJ-45
RJ-45
RJ-45
RJ-45
RJ-45
RJ-45
2 km (1.2 mi)
2 km (1.2 mi)
100 m (328 ft)
100 m (328 ft)
15 km (9.3 mi) 100 m (328 ft)
40 km
(24.8 mi)
100 m (328 ft)
100 m (328 ft) 75 km
(46.5 mi)
75 km
(46.5 mi)
100 m (328 ft)
100 km (62 mi)
100 km (62 mi)
100 m (328 ft)
100 m (328 ft)
1. Maximum distance may be less depending on the duplex mode of the end stations and the type of fiber optic cabling used with the port.
2
Key Features
The media converters have the following key features:
❑ LEDs for unit and port status
❑ MDI/MDI-X button
❑ Link Test/MissingLink
button for performing a link test and activates the MissingLink feature which notifies end-nodes of connection failures
❑ 100Base-TX twisted pair port operates in half- or full-duplex mode
❑ 100Base-FX fiber optic port operates in half- or full-duplex mode
❑ External AC/DC power adapter
❑ Standard size for use in an AT-MCR12 chassis
AT-MC100 Series Installation Guide
Status LEDs
Table 2 defines the media converter’s LEDs.
LED
PWR
LNK
ACT
FDX
OFF
M/L ON ON
ON
ON
ON
ON
State Color
Green
Green
Green
Green
Green
OFF
Table 2 Status LEDs
Description
Power is applied to the media converter.
A link has been established on the port.
Data is being received on the port.
The port is operating in full-duplex mode.
The port is operating in half-duplex mode.
The MissingLink feature is activated on the media converter.
The MissingLink feature is disabled and the media converter is operating in the link test mode.
MDI/MDI-X Button
An RJ-45 port on a 100 Mbps Ethernet network device can have one of two possible wiring configurations: MDI or MDI-X. The RJ-45 port on a PC, router or bridge is typically wired as MDI, while the twisted pair port on a switch or hub is usually MDI-X.
To connect two 100 Mbps network devices together that have dissimilar port wiring configurations, such as MDI to MDI-X, you use a straight-through cable. To connect two network devices that have an RJ-45 port with the same wiring configuration, such as MDI to MDI, you use a crossover cable.
The RJ-45 port on the media converter features an MDI/MDI-X button. You can use this button to configure the twisted pair port on the media converter as either MDI or MDI-X. This feature allows you to use a straight-through cable regardless of the type of end-node connected to the port.
Note
After a using the MDI/MDI-X button to change between the two settings, you must reset the media converter by powering OFF then powering ON the unit.
3
Overview
Link Test/MissingLink Button
The Link Test/MissingLink button allows you to perform a link test on the ports on the media converter. This button also allows you to activate the
MissingLink feature on the unit. Both features are describe in the following section.
Note
After using the Link Test/MissingLink button to select between the two settings, you must reset the media converter by powering OFF then powering ON the unit
Link Test.
The link test is a fast and easy way for you to test the connections between the ports on the media converter and the nodes that are connected to the ports. If a network problem occurs, you can perform a link test to determine which port is experiencing a problem, and be able to focus on the port and end-node where the problem resides.
A link test is performed when the button is in the LNK TST (OUT) position.
For instructions on performing a link test, refer to “Troubleshooting” on page
Note
Leaving the media converter in the LNK TST (OUT) position will not interfere with the units ability to pass network traffic. Leaving the unit in this position will ensure that after a network recovery, the media converter will automatically resume passing network traffic.
MissingLink.
The MissingLink feature enables the fiber optic ports on the media converter to pass the “Link” status of their connections to each other.
When the media converter detects a problem with one of the ports, such as the loss of connection to an end-node, the media converter shuts down the connection to the other port, thus notifying the node that the connection has been lost.
For example, if the twisted pair cable to the 100Base-TX port on the media converter were to fail, the media converter would respond by dropping the link on the 100Base-FX fiber optic port. In this way, the media converter notifies the end-node connected to the fiber optic port that the connection on the twisted pair port has been lost. If the failure had started with the fiber optic cabling, the unit would drop the link to the twisted pair port.
4
AT-MC100 Series Installation Guide
The value to this type of network monitoring and fault notification is that some hubs and switches can be configured to take a specific action in the event of the loss of connection on a port. In some cases, the unit can be configured to seek a redundant path to a disconnected node or send out a trap to a network management station, and so alert the network administrator of the problem.
Note
The MissingLink feature is disabled when you perform a link test with the Link Test/MissingLink button. Consequently, to ensure that the
MissingLink feature is activated on the media converter, always set the button to the M/L ON (IN) position during normal network operations.
However, if left in this position and there is a network failure, after recovery you must physically set the unit to LNK TST (OUT) then back to M/L ON (IN) for the media converter to resume passing network traffic.
Auto-negotiation Button
The auto-negotiation button, located on the front panel, disables the autonegotiation feature (IEEE 802.3u) of the media converter. The media converter uses auto-negotiation to determine the duplex mode of the ports.
The duplex mode refers to the manner in which an end-node sends and receives data on the network. An end-node can operate in either half- or fullduplex mode. A node operating in half-duplex can either send or receive data, but not both at the same time. An end-node operating in full-duplex can send and receive data simultaneously. The best network performance is achieved when an end-node can operate in full-duplex mode.
In most configurations, you will want to leave the auto-negotiation button activated so the unit can determine the appropriate duplex mode, based on the capabilities of the end-nodes. For example, the auto-negotiation feature on the media converter should be left activated in situations where both end-nodes are also capable of auto-negotiation, or where both end-nodes have been preset to the same mode or are capable of operating in only one duplex mode, such as half-duplex.
Note
After a configuration change, you must reset the media converter by powering OFF then powering ON the unit
5
Overview
There is one situation where it may be necessary to disable the autonegotiation feature, and that is to prevent a mismatch from occurring between
the duplex modes of the end-nodes. For example, Figure 2 shows two units
that have been connected with a media converter. Unit 1 is a repeater that is capable of operating in half-duplex mode only. Unit 2 is a switch that can operate in either half- or full-duplex mode, and will auto-negotiation the duplex mode.
In attempting to auto-negotiate with Unit 1, the media converter will determine that the unit is capable of half-duplex only and will set the port connected to the unit appropriately. In auto-negotiating with Unit 2, the media converter will determine that the unit can manage full-duplex and will set the port connected to the unit to full-duplex. The result is a mismatch, with one unit operating in half-duplex and the other unit operating in full-duplex. This is referred to as a classic duplex mode mismatch and will result in poor network performance between the end-nodes.
Unit 1
Unit 2
100Base-TX Repeater
CLASS 1
LASER PRODUCT
DO NOT STARE
INTO BEAM
TX RX
100Base-FX
LNK
A/N ON
100Base-TX
MDI
LNK TST
ACT A/N OFF MDI-X
SINGLE MODE
MC103SC/FS3 FAST ETHERNET MEDIA CONVERTER
Media Converter
FDX
LNK
PWR
ACT M/L ON
100Base-TX Switch
Figure 2 Example of a Duplex Mode Mismatch
You can resolve the mismatch in one of two ways:
❑
Manually configure Unit 2, if possible, so that the port connected to the media converter is set to half-duplex.
❑ Disable auto-negotiation on the media converter using the autonegotiation button. With auto-negotiation on the media converter disabled, Unit 2 will assume that the converter is capable of only halfduplex operation, thus eliminating the mismatch in duplex modes between the end-nodes.
External AC/DC Power Adapter
An external AC/DC power adapter is included with the media converter for standalone operation. The power adapter supplies 12V DC to the media converter. Allied Telesyn supplies an approved safety compliant AC power adapter for the 120 and 240V AC versions with an unregulated output of 12V
DC at 1 A. The power required for the media converter is 12V DC, 500 mA.
6
AT-MC100 Series Installation Guide
Network Topologies
The AT-MC100 Series Media Converters can be used in two different types of topologies: standalone and back-to-back. Both topologies are described below.
Standalone Topology
Figure 3 illustrates a standalone topology where two AT-8224XL switches
have been interconnected with an AT-MC102XL media converter.
AT-8224XL
10BASE-T / 10 0BASE-TX
FAST ETHERNET
SWITCH
10BASE-T / 10
0BASE-TX
PORT ACTIVITY
RS-232
TERMINAL POR
STATUS
100 m (328 ft)
AT-MC102XL
M/L ON
LNK TST
TX RX
100Base-FX 100Base-TX
LNK
A/N ON MDI
ACT A/N OFF MDI-X
MC102XL FAST ETHERNET MEDIA CONVERTER
FDX
LNK
PWR
ACT M/L ON
2 km (1.2 mi)
Cable Legend
100 Mbps
100 Mbps (Fiber)
PORT ACTIVITY
RS-232
TERMINAL POR
STATUS
10BASE-T / 10
0BASE-TX
10BASE-T / 10 0BASE-TX
FAST ETHERNET SWITCH
AT-8224XL with an AT-A17
Expansion Module
Figure 3 Standalone Topology
7
Overview
Back-to-Back Topology
Figure 4 illustrates two media converters in a back-to-back configuration.
AT-8224XL
AT-MC103SC/FS3
CLASS 1
LASER PRODUCT
DO NOT STARE
INTO BEAM
M/L
ON
TX RX 100Base-FX 100Base-TX
LNK A/N ON MDI
LNK TST
ACT A/N OFF
SINGLE MODE
MC103SC/FS3 FAST ETHERNET MEDIA CONVERTER
MDI-X
FDX
LNK
PWR
ACT M/L ON
100 m (328 ft)
FAST ETHERNE
T SWITCH
10BASE-T / 10 0BASE-TX
PORT ACTIVIT
RS-232
TERMINAL POR
STATUS
75 km (46.5 mi)
AT-MC103SC/FS3
CLASS 1
LASER PRODUCT
M/L
ON
TX RX
100Base-FX 100Base-TX
A/N ON MDI
LNK
LNK TST ACT A/N OFF
SINGLE MODE
MC103SC/FS3 FAST ETHERNET MEDIA CONVERTER
MDI-X
FDX
LNK
PWR
ACT M/L ON 100 m (328 ft)
AT-8224XL
0BASE-TX
10BASE-T / 10 SWITCH
10BASE-T / 10 0BASE-TX
PORT ACTIVITY
STATUS
Cable Legend
10 Mbps
100 Mbps
100 Mbps (Fiber)
Figure 4 Back-to-Back Topology
8
Chapter 2
Installing the Media Converter
Verifying the Package Contents
Make sure the following items are included in your package. If any item is missing or damaged, contact your Allied Telesyn sales representative for assistance.
❑ One AT-MC100 Series Fast Ethernet Media Converter
❑ Four protective feet (for desktop use only)
❑ An external AC/DC power adapter
❑
This installation guide
❑ Warranty card
Planning the Installation
Be sure to observe the following guidelines when planning the installation of your media converter.
❑ The end-nodes connected to the media converter must operate at 100
Mbps.
❑ The two end-nodes connected to the ports of the media converter must operate with the same duplex mode, either half- or full-duplex. The media converter itself can operate in either mode.
❑
The devices connected to the two ports on the media converter can be a network adapter card, repeater, switch, or router.
❑
Refer to Table 3, Table 4, and Table 5 for the twisted pair and fiber
optic port specifications.
9
Installing the Media Converter
Table 3 100Base-TX Twisted Pair Port Cabling Specifications
Cable Type
Shielded or unshielded Category 5 or better
Maximum Operating Distance
100 m (328 ft)
Table 4 100Base-FX Fiber Optic Port Specifications (Full-duplex)
Model Type of Fiber Optic
Cable
Maximum
Operating
Distance
Maximum Allowable
Loss Budget
AT-MC101XL
AT-MC102XL
AT-MC103XL
50/125 or 62.5/125 micron multimode
50/125 or 62.5/125 micron multimode
9/125 micron single-mode
AT-MC103LH 9/125 micron single-mode
AT-MC103SC/FS3 9/125 micron single-mode
AT-MC103ST/FS3 9/125 micron single-mode
AT-MC103SC/FS4 9/125 micron single-mode
AT-MC103ST/FS4 9/125 micron single-mode
2 km (1.2 mi)
2 km (1.2 mi)
15 km (9.3 mi)
40 km (24.8 mi)
75 km (46.5 mi)
75 km (46.5 mi)
100 km (62 mi)
100 km (62 mi)
2
2
1
1
13 dB at 1310 nm
13 dB at 1310 nm
16 dB at 1310 nm
16 dB at 1310 nm
33 dB at 1310 nm
33 dB at 1310 nm
34 dB at 1550 nm
34 dB at 1550 nm
1. The media converter has a minimum operating distance of 15 km (9.4 mi). This is to prevent blinding or burning out of the optical receiver on the far-end-node.
2. The media converter has a minimum operating distance of 40 km (24.8 mi). This is to prevent blinding or burning out of the optical receiver on the far-end-node.
10
AT-MC100 Series Installation Guide
Table 5 100Base-FX Fiber Optic Port (Half-duplex)
1
Number of Media Converters Connected Devices Maximum Operating
Distance
One Media Converter Inline Switch to Switch
Workstation to Switch
Switch to Class I Repeater
Switch to Class II Repeater
372 m (1,221 ft)
372 m (1,221 ft)
137 m (450 ft)
185 m (607 ft)
Two Media Converters Inline Switch to Switch
Workstation to Switch
332 m (1,089 ft)
332 m (1,089 ft)
Switch to Class I Repeater 97 m (318 ft)
Switch to Class II Repeater 145 m (476 ft)
1. The total distance of all fiber lengths cannot exceed the limits stated in the table. Each media converter used inline within a single collision domain reduces the overall segment length by 40 meters (131 feet).
Reviewing Safety Precautions
Please review the following safety guidelines before installing the media converter.
Warning
Class 1 laser product. !
6
Warning
Do not stare into the laser beam.
!
7
Warning
Lightning Danger: Do not work on equipment or cables during periods of lightening activity. !
8
Caution
Do not block air vents.
!
9
Caution
Power to the hub must be sourced only from the adapter. !
10
Caution
Operating Temperature: This product is designed for a maximum ambient temperature of 40°C. !
11
11
Installing the Media Converter
Caution
All Countries: Install this product in accordance with local and
National Electric Codes. !
12
Installing the Media Converter
The following procedure explains how to install an AT-MC100 Series Media
Converter.
To install the media converter, perform the following procedure:
1.
Remove all equipment from the package and store the packaging material in a safe place.
Note
Do not remove the dust cover from the fiber optic port until you are ready to connect the fiber optic cable. Dust contamination can adversely impact the operating performance of the port on the media converter.
2.
If you are installing the media converter in an AT-MCR12 chassis, refer to the chassis’s installation guide for instructions on how to install the unit,
3.
Place the media converter on a flat, secure surface (such as a desk or table) leaving ample space around the unit for ventilation.
4.
Attach the four protective rubber feet to the bottom of the media
converter. See Figure 5. Do not attach the protective feet if you are
installing the unit in an AT-MCR12 chassis.
PWR
M/L ON
LNK
FDX
T AC
0Base-TX
MDI
MDI-X
10
A/N ON
A/N OFF T AC
LNK
0Base-FX 10
RX
Figure 5 Attaching the Protective Feet
TX
MC102XL FAST ETHERNET MEDIA CONVERTER
LNK TST
M/L ON
12
AT-MC100 Series Installation Guide
5.
Set the Link Test/MissingLink button to LNK TST (OUT) position.
6.
Set the auto-negotiation feature as follows:
❑
If both end-nodes will use auto-negotiation to determine the duplex mode, or if both are pre-set to operate with the same duplex mode, such as half-duplex, set the switch to the A/N ON (IN) position. This is the default setting.
❑ If one end-node is capable of operating at only half-duplex mode while the other node will determine its duplex mode through autonegotiation, set the switch to the A/N OFF (OUT) position.
7.
Plug the AC/DC power adapter into an appropriate AC power outlet and insert the power plug into the DC receptacle located on the back of the
unit. Refer to Figure 6. This step does not apply if you installed the
unit in an AT-MCR12 chassis.
Power Plug
DC Receptacle
12 V D C
AC/DC Power Adapter
DC Polarity Symbols
Back of Media Converter
Figure 6 12 V DC Connector on Rear Panel
8.
Verify that the PWR LED is green. If the LED is OFF, refer to
9.
Remove the dust cover from the fiber optic connector and connect the cable to the fiber optic port. Verify that the media converter’s transmitter port (TX) is connected to the end-node’s receiver port (RX) and that the media converter’s receiver port (RX) is connected to the end-node’s transmitter port (TX).
10. Connect the twisted pair cable to the twisted pair port.
Note
End-nodes connected to the media converter must operate with the same duplex mode, either both full-duplex or both half-duplex.
13
Installing the Media Converter
11. Set the MDI/MDI-X button as follows:
❑
If you are connecting a workstation to the 100Base-TX port, set the
MDI/MDI-X button to the MDI-X (OUT) position. MDI-X is the default position.
❑ If you are connecting a hub or a switch to the 100Base-TX port, set the
MDI/MDI-X switch to the MDI (IN) position.
Note
After a using the MDI/MDI-X button to change between the two settings, you must reset the media converter by powering OFF then powering ON the unit.
12. Power ON the end-nodes.
The media converter is now ready for use.
Warranty Registration
When you finish installing the product, you should register your product by completing the enclosed warranty card and sending it in.
14
Chapter 3
Troubleshooting
Troubleshooting Guidelines
Follow the guidelines below to test and troubleshoot the installation in the event a problem occurs.
If the PWR LED is OFF, do the following:
❑ If the unit is installed on a desktop, check to be sure that the power adapter is securely connected to a power outlet and that the power adapter cable is securely connected to the back of the media converter.
❑ If the unit is installed in an AT-MCR12 chassis, check that the unit is fully seated in the slot.
❑
Verify that the power outlet has power by connecting another device to it.
❑ Try using another power adapter of the same type that came with your media converter.
If the LNK LED for the twisted pair port is OFF, do the following:
❑ Check that the end-node connected to the port is powered ON and is operating properly.
❑
Check that the twisted pair cable is securely connected to the twisted pair port on the media converter and on the remote end-node.
❑ Make sure that the twisted pair cable does not exceed 100 meters (328 feet) and that you are using Category 5 or better.
❑
Verify that both end-nodes connected to the media converter are operating at the same speed. Both must be operating at either 100
Mbps.
❑
Make sure no configuration changes have been made. If so, you must reset the media converter by powering OFF and then powering ON the unit.
15
Troubleshooting
If the LNK LED for the fiber optic port is OFF, do the following:
❑ Verify that then end-node connected to the port is ON and is operating properly.
❑
Check that the fiber optic cable is securely connected to the fiber optic port on the media converter and on the end-node.
❑ Verify that the end-nodes connected to the media converter are operating at the same speed. Both must be operating at 100 Mbps.
❑
Make sure that the cable connected to the media converter’s receiver port (RX) is connected to the end-node’s transmitter port (TX) and that the media converter’s transmitter port (TX) is connected to the endnode’s receiver port (RX).
❑ Make sure no configuration changes have been made. If so, you must reset the media converter by powering OFF then powering ON the unit.
❑ Test the attenuation on the fiber optic cable to ensure that it does not
❑ Verify that you are using the appropriate type of fiber optic cable and that you have not exceeded the maximum operating distance. For
maximum operating distances, refer to Table 1 on page 2. For cable
types, refer to “Fiber Optic Port Specifications” on page 20.
❑
Check that the operating specifications (e.g., wavelength and maximum operating distance) of the fiber optic port on the end-node are compatible with the operating specifications of the fiber optic port
on the media converter. Refer to “Fiber Optic Port Specifications” on page 20 for more information.
If there is a communication problem between the end-nodes connected to the media converter, do the following:
❑
Verify that both end-nodes are operating with the same duplex mode.
If you are still experiencing problems after testing and troubleshooting the
installation, refer to “Contacting Allied Telesyn Technical Support” on page x
or visit our web site at www.alliedtelesyn.com for support information.
16
AT-MC100 Series Installation Guide
Loopback Test
To check hardware reliability of the media converter, perform the following procedure:
1.
Power OFF the media converter by unplugging the power adapter from the wall outlet and from the back of the unit.
2.
Connect the RJ-45 twisted pair port to a 100Base port on the end-node and power ON the end-node.
3.
Set the MDI/MDI-X button as follows:
❑
If you are connecting a workstation to the 100Base port, set the MDI/
MDI-X button to the MDI-X (OUT) position. MDI-X is the default position.
❑
If you are connecting a hub or a switch to the 100Base port, set the
MDI/MDI-X switch to the MDI (IN) position.
4.
Using a tested and good fiber patch cable, attach the matching ends of the fiber cable to the transmit (TX) and receive (RX) connectors of the media converter.
5.
Set the media converter to the LNK TST(OUT) position.
6.
Power ON the media converter.
7.
Verify that the LNK LED on both the twisted pair and fiber optic ports are green.
❑
If the LEDs are green, the unit is working properly and there is a problem elsewhere on the segment.
❑ If the LEDs are OFF, contact Allied Telesyn Technical Support for a
accessing the Knowledge Base at http:\\kb.alliedtelesyn.com.
17
Appendix A
Technical Specifications
Physical
Dimensions:
Weight:
Electrical Rating
Input Supply Voltage:
Maximum Current:
Power Consumption:
W x D x H
10.5 cm x 9.5 cm x 2.5 cm
(4.125 in x 3.75 in x 1.0 in)
0.27 kg (0.60 lbs)
Environmental
Maximum Operating Temperature: 0° C to 40° C (32° F to 104° F)
Maximum Storage Temperature: -20° C to 60° C (-4° F to 140° F)
Operating and Storage Altitude: Up to 3,048 meters (10,000 feet)
Relative Humidity Operating and Storage: 5% to 95% (non-condensing)
12V DC ± 5%
500 mA
6W
19
Technical Specifications
Agency Certifications
EMI/RFI:
Electrical Safety:
Immunity:
FCC Class B, EN55022 Class B,
VCCI Class B
EN60950 (TUV), UL1950 ( c
UL us
),
CE Compliant
EN55024 VCCI Class B
Fiber Optic Port Specifications
Table 6 through Table 9 lists the specifications for the 100Base-FX fiber optic
port.
Table 6 Fiber Optic Transmitter
Model Fiber
Type
1
Fiber
Optic
Diameter
(microns)
Optical
Wavelength
Launch Power (dBm)
2
AT-MC101XL and
AT-MC102XL
AT-MC103XL
AT-MC103LH
AT-MC103SC/FS3 and
AT-MC103ST/FS3
MMF
MMF
SMF
SMF
SMF
50/125
62.5/125
9/125
9/125
9/125
1310 nm
1310 nm
1310 nm
1310 nm
1310 nm
AT-MC103SC/FS4 and
AT-MC103ST/FS4
SMF 9/125 1550 nm
1. MMF = Multimode Fiber / SMF = Single-mode Fiber
2. The launch power is measured at one meter from the transmitter.
-8.0
0.0
0.0
Max.
-14.0
-14.0
0.0
Avg.
Min.
-20.3
-22.5
-16.8
-19.0
-11.5
-15.0
-3.0
-2.0
-5.0
-4.0
-1.5
-3.0
20
AT-MC100 Series Installation Guide
Model
Table 7 Fiber Optic Receiver
Fiber
Type
1
Fiber
Optic
Diameter
(microns)
Optical
Wavelength
Receive Power (dBm)
Min.
Typical Saturation
-31.8
-34.5
-14.0
AT-MC101XL and
AT-MC102XL
AT-MC103XL
AT-MC103LH
AT-MC103SC/FS3 and
AT-MC103ST/FS3
MMF 50/125 or
62.5/125
1310 nm
SMF 9/125
SMF 9/125
SMF 9/125
1310 nm
1310 nm
1310 nm
AT-MC103SC/FS4 and
AT-MC103ST/FS4
SMF 9/125
1. MMF = Multimode Fiber / SMF = Single-mode Fiber
1550 nm
-31.0
-37.0
-31.0
-35.0
-38.0
-37.0
-37.0
-37.0
-8.0
0.0
-3.0
-3.0
Model
AT-MC101XL and
AT-MC102XL
AT-MC103XL
AT-MC103LH
Table 8 Fiber Optic Datalink
Fiber
Type
1
Minimum
Power /
Link
Budget
Average
Signal
Loss
50/125
MMF
62.5/125
MMF
13.00 dB
16.80 dB
9/125 SMF 16.00 dB
18.70 dB 0
22.50 dB
19.50 dB
0
0
9/125 SMF 30.00 dB 35.00 dB
Minimum
Distance
Spec.
2
Maximum
Distance
Spec.
0
2 km
(1.2 mi)
2 km
(1.2 mi)
15 km
(9.4 mi)
40 km
(24.8 mi)
21
Technical Specifications
Table 8 Fiber Optic Datalink (Continued)
Model Fiber
Type
1
Minimum
Power /
Link
Budget
Average
Signal
Loss
Minimum
Distance
Spec.
2
Maximum
Distance
Spec.
AT-MC103SC/FS3 and
AT-MC103ST/FS3
AT-MC103SC/FS4 and
AT-MC103ST/FS4
9/125 SMF
9/125 SMF
33.00 dB
34.00 dB
35.00 dB
35.50 dB
15 km
(9.4 mi)
40 km
(24.8 mi)
75 km
(46.5 mi)
100 km
(62 mi)
1. MMF = Multimode Fiber / SMF = Single-mode Fiber
2. The recommended minimum range is stated in all cases where the maximum transmitter output power exceeds the receivers saturation level. This is to prevent blinding or burning out of the optical receiver on the far-end-node.
Fiber Type
MMF
SMF
1
Table 9 Fiber Optic Loss Specifications (Benchmarks)
Fiber Optic
Diameter
(microns)
50/125
50/125
62.5/125
62.5/125
100/140
9/125
9/125
Optical
Wavelength
850 nm
1310 nm
850 nm
1310 nm
850 nm
1310 nm
1550 nm
1. MMF = Multimode Fiber / SMF = Single-mode Fiber
Typical
Loss
Factor
(dB/km)
3.00
1.00
3.00
1.00
4.00
0.40
0.30
Worst Case
Loss Factor
(dB/km)
3.50
1.50
3.75
1.50
4.00
1.00
0.75
Bandwidt h (Mhzkm)
100
N/A
N/A
400
400
200
500
22
Appendix B
Translated Electrical Safety and Emission
Information
Important: This appendix contains multiple-language translations for the safety statements in this guide.
Wichtig: Dieser Anhang enthält Übersetzungen der in diesem Handbuch enthaltenen Sicherheitshinweise in mehreren Sprachen.
Vigtigt: Dette tillæg indeholder oversættelser i flere sprog af sikkerhedsadvarslerne i denne håndbog.
Belangrijk: Deze appendix bevat vertalingen in meerdere talen van de veiligheidsopmerkingen in deze gids.
Important: Cette annexe contient la traduction en plusieurs langues des instructions de sécurité figurant dans ce guide.
Tärkeää: Tämä liite sisältää tässä oppaassa esiintyvät turvaohjeet usealla kielellä.
Importante: questa appendice contiene traduzioni in più lingue degli avvisi di sicurezza di questa guida.
Viktig: Dette tillegget inneholder oversettelser til flere språk av sikkerhetsinformasjonen i denne veiledningen.
Importante: Este anexo contém traduções em vários idiomas das advertências de segurança neste guia.
Importante: Este apéndice contiene traducciones en múltiples idiomas de los mensajes de seguridad incluidos en esta guía.
Obs! Denna bilaga innehåller flerspråkiga översättningar av säkerhetsmeddelandena i denna handledning.
23
Translated Electrical Safety and Emission Information
Standards: This product meets the following standards.
U.S. Federal Communications Commission
Declaration Of Conformity
Manufacture Name:
Manufacture Address:
Manufacture Telephone:
Allied Telesyn, Inc.
960 Stewart Drive, Suite B
Sunnyvale, CA 94086 USA
408-730-0950
Declares that the Product:
Model Numbers:
Fast Ethernet Media Converters
AT-MC101XL, AT-MC102XL,
AT-MC103XL, AT-MC103LH,
AT-MC103SC/FS3,
AT-MC103ST/FS3
AT-MC103SC/FS4,
AT-MC103ST/FS4
This product complies with FCC Part 15B, Class B Limits:
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device must not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Radiated Energy
Note: This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of FCC Rules.
These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with instructions, may cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on; the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and the receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
Changes and modifications not expressly approved by the manufacturer or registrant of this equipment can void your authority to operate this equipment under Federal Communications Commission rules.
Warning: This product requires only Category 3, 4, or 5 shielded twisted-pair cable for all 10 Mbps RJ-45 connections, and Category 5 shielded twisted-pair for all 100 Mbps RJ-45 connections to comply with
Class B emission limits. If not used with shielded cables, this product may cause radio interference in which case the user may be required to take adequate measures to reduce interference levels.
24
AT-MC100 Series Installation Guide
! 1
! 2
! 3
! 4
! 5
! 6
! 7
! 8
! 9
! 10
! 11
Industry Canada
This Class B digital apparatus meets all requirements of the Canadian
Interference-Causing Equipment Regulations.
Cet appareil numérique de la classe B respecte toutes les exigences du
Règlement sur le matériel brouilleur du Canada.
RFI Emission
Immunity
EN55022 Class B
EN50082-1 1997
Warning: This product requires shielded cables to comply with emission and immunity standards. If it is used with unshielded cables, the user may be required to take measures to correct the interference problem at their own expense.
Electrical Safety
Safety
EN60950 (TUV), UL1950 ( c
UL us
)
Laser
Warning: Class 1 Laser product.
EN60825
Warning: Do not stare into the Laser beam.
At time of installation, the Fiber Optic Lasers comply with FDA Radiation
Performance Standard 21CFR Subchapter J, applicable at date of manufacture. Use of controls or adjustments of performance or procedures other than those specified herein may result in hazardous radiation exposure.
Lightning Danger
Danger: Do not work on equipment or cables during periods of lightning activity.
Do not block air vents
Power to the hub must be sourced only from the adapter.
USA/Canada
Use a UL Listed/CSA Certified AC adapter of DC 12V, 500mA.
Europe - EU
Use TÜV licensed AC adapter of DC 12V, 500mA.
UK
Use a UK Safety Approved AC adapter of DC 12V, minimum 500mA.
Operating Temperature: This product is designed for a maximum ambient temperature of 40 degrees C.
25
Translated Electrical Safety and Emission Information
! 12 All Countries: Install product in accordance with local and National
Electrical Codes.
! 1
! 2
! 3
! 4
! 5
! 6
! 7
! 8
! 9
! 10
! 11
! 12
Normen: Dieses Produkt erfüllt die Anforderungen der nachfolgenden
Normen.
Hochfrequenzstörung EN55022 Klasse B
Störsicherheit EN50082-1 1997
Achtung: Für dieses Produkt sind abgeschirmte Kabel erforderlich, damit den Richtlinien für Emission und Interferenzschutz entsprochen wird. Falls das Produkt mit nicht abgeschirmten Kabeln verwendet wird, können weitergehende Maßnahmen für die Korrektur von Interferenzproblemen auf
Kosten des Benutzers notwendig werden.
Elektrische Sicherheit
Sicherheit
EN60950 (TUV), UL1950 (
Laser EN60825
Warnung: Laserprodukt der Klasse 1.
c
UL us
)
Warnung: Nicht direkt in den Strahl blicken.
Gefahr Durch Blitzschlag
Gefahr: Keine Arbeiten am Gerät oder an den Kabeln während eines
Gewitters ausführen
Entlüftungsöffnungen nicht versperren
Der Buchse darf nur aus dem Adapter Strom zugeführt werden.
Europe - EU
Gebrauchen Sie einen von TÜV zugelassenen Wechselstromadapter für
Gleichstrom 12 V, 500 mA.
Betriebstemperatur: Dieses Produkt wurde für den Betrieb in einer
Umgebungstemperatur von nicht mehr als 40° C entworfen.
Alle Länder: Installation muß örtlichen und nationalen elektrischen
Vorschriften entsprechen.
26
AT-MC100 Series Installation Guide
! 1
! 2
! 3
! 5
! 6
! 7
! 8
! 9
! 10
Standarder: Dette produkt tilfredsstiller de følgende standarder.
Radiofrekvens forstyrrelsesemissionEN55022 Klasse B
! 4
! 11
! 12
Advarsel: Dette produkt skal bruges med afskærmede kabler for at overholde bestemmelserne vedrørende udstråling og støjimmunitet. Hvis det bruges med uafskærmede kabler, kan det blive påkrævet af brugeren at korrigere interferensproblemer for egen regning.
Elektrisk sikkerhed.
EN60950 (TUV), UL1950 ( c
UL us
)
Sikkerhed
Laser EN60825
Advarsel: Laserprodukt av klasse 1.
Advarsel: Stirr ikke på strålen.
Fare Under Uvejr
Fare: Undlad at arbejde på udstyr eller kabler i perioder med lynaktivitet.
Ventilationsåbningerne må ikke blokeres
Strømforsyningen til apparatet må udelukkende tages fra tilpasningstransformatoren.
Europe - EU
Brug kun TÜV godkendt vekselstrømstransformator på 12 V jævnstrøm,
500 mA.
Betjeningstemperatur: Dette apparat er konstrueret til en omgivende temperatur på maksimum 40 grader C.
Alle Lande: Installation af produktet skal ske i overensstemmelse med lokal og national lovgivning for elektriske installationer.
27
Translated Electrical Safety and Emission Information
! 5
! 6
! 7
! 8
! 9
! 10
! 1
! 2
! 3
! 4
! 11
! 12
Eisen: Dit product voldoet aan de volgende eisen.
RFI Emissie EN55022 Klasse B
Immuniteit EN50082-1 1997
Waarschuwing: Om te voldoen aan de emissie- en immuniteitsnormen dient dit apparaat te zijn voorzien van afgeschermde kabels. Als het met niet-afgeschermde kabels wordt gebruikt, kan het zijn dat de gebruiker maatregelen moet treffen om interferentieproblemen voor eigen rekening op te lossen.
Electrische Veiligheid
Veiligheid
EN60950 (TUV), UL1950 (
Laser EN60825
Waarshuwing: Klasse-1 laser produkt.
c
UL us
)
Waarchuwing: Neit in de straal staren.
Gevaar Voor Blikseminslag
Gevaar: Niet aan toestellen of kabels werken bij bliksem.
Ventilatiegaten niet blokkeren
Stroom mag alleen via de adapter naar het apparaat toegevoerd worden.
Europe - EU
Gebruik een door TÜV gekeurde wisselstroomadapter van 12 Volt gelijkstroom, 500 milliampères.
Bedrijfstemperatuur: De omgevingstemperatuur voor dit produkt mag niet meer bedragen dan 40 graden Celsius.
Alle Landen: het toestel installeren overeenkomstig de lokale en nationale elektrische voorschriften.
28
AT-MC100 Series Installation Guide
! 5
! 6
! 7
! 8
! 9
! 10
! 1
! 2
! 3
! 4
! 11
! 12
Normes: ce produit est conforme aux normes de suivantes.
Emission d'interférences radioélectriques
Immunité
EN55022 Classe B
EN50082 - 1 1997
Avertissement: Il faut utiliser des câbles blindés pour ce produit afin de respecter les normes d’émission et d’immunité. Si l’utilisateur choisit d’utiliser des câbles non blindés, il sera peut-être contraint de prendre les mesures nécessaires pour corriger les problèmes d’interférences, ainsi que d’assumer le coût correspondant.
Sécurité Électrique EN60950 (TUV), UL1950 ( c
UL us
)
Sécurité
Laser EN60825
Attention Producit laser di classe 1.
Attention Ne pas fixer le faisceau des yeux.
Danger De Foudre
Danger: Ne pas manier le matériel ou les câbles lors d'activité orageuse.
Ne pas bloquer les fentes d'aération
L'alimentation du concentrateur doit être uniquement fournie par l'adaptateur.
Europe - EU
Utiliser un adaptateur secteur conforme TÜV de 12 V, 500 mA en courant continu.
Température De Fonctionnement: Ce matériel est capable de tolérer une température ambiante maximum de 40 degrés Celsius.
Pour Tous Pays: Installer le matériel conformément aux normes
électriques nationales et locales.
29
Translated Electrical Safety and Emission Information
! 1
! 2
! 3
! 4
! 5
! 6
! 7
! 8
! 9
! 10
! 11
! 12
Standardit: Tämä tuote on seuraavien standardien mukainen.
Radioaaltojen häirintä EN55022 Luokka B
Kestävyys EN50082-1 1997
Varoitus: Tämä tuote vaatii suojattuja kaapeleita toimiakseen emissio- ja häiriönsietostandardien mukaisesti. Jostuotetta käytetään ilman suojattuja kaapeleita, käyttäjä voi joutua korjaamaan häirinnän aiheuttaman ongelman omallakustannuksellaan.
Sähköturvallisuus EN60950 (TUV), UL1950 ( c
UL us
)
Turvallisuus
Laser EN60825
Varoitus: Luokan 1 Lasertuote.
Variotus: Älä katso säteeseen.
Salamaniskuvaara
Engenvaara: Älä työskentele laitteiden tai kaapeleiden kanssa salamoinnin aikana.
Älä tuki ilmareikiä
Tähtipisteeseen (hub) syötettävän virran pitää tulla ainoastaan sovittimesta.
Europe - EU
Käytä TÜV-lisenssillä valmistettua verkkosovitinta, jonka tasajännitteen nimellisarvot ovat DC 12 V, 500 mA (milliampeeria).
Käyttölämpötila: Tämä tuote on suunniteltu ympäröivän ilman maksimilämpötilalle 40° C.
Kaikki Maat: Asenna tuote paikallisten ja kansallisten sähköturvallisuusmääräysten mukaisesti.
30
AT-MC100 Series Installation Guide
! 1
! 2
! 3
! 4
! 5
! 6
! 7
! 8
! 9
! 10
! 11
! 12
Standard: Questo prodotto è conforme ai seguenti standard.
Emissione RFI (interferenza di radiofrequenza)
Immunità
EN55022 Classe B
EN50082-1 1997
Avvertenza: questo prodotto, se utilizzato con cavi schermati, è conforme alle norme sulle emissioni e sull’immunità. In caso di uso senza cavi schermati, l’utente può dover adottare a proprie spese misure correttive contro le interferenze.
Sicurezza Elettrica
Norme Di Sicurezza
EN60950 (TUV), UL1950 ( c
UL us
)
Laser EN60825
Avvertenza: Prodotto laser di Classe 1.
Avertenza: Non fissare il raggio con gli occhi.
Pericolo Di Fulmini
Pericolo: Non lavorare sul dispositivo o sui cavi durante precipitazioni temporalesche.
Non ostruire le prese d'aria
Questo dispositivo deve essere alimentato solo mediante l’adattatore.
Europe - EU
Utilizzare l’adattatore per c.a. da 12 V c.c. e 500 mA conforme alla normativa
TÜV.
Temperatura Di Funzionamento: Questo prodotto è concepito per una temperatura ambientale massima di 40 gradi centigradi.
Tutti I Paesi: installare il prodotto in conformità delle vigenti normative elettriche nazionali.
31
Translated Electrical Safety and Emission Information
! 5
! 6
! 7
! 8
! 9
! 10
! 1
! 2
! 3
! 4
! 11
! 12
Sikkerhetsnormer: Dette produktet tilfredsstiller følgende sikkerhetsnormer.
RFI stråling EN55022 Klasse B
Immunitet EN50082-1 1997
Advarsel: Dette produktet må brukes med vernede kabler for å tilfredsstille emisjons- og fritakelsesstandarder. Dersom produktet brukes med uvernede kabler, må brukeren muligens rette forstyrrelsesproblemene for egen regning.
Elektrisk sikkerhet EN60950 (TUV), UL1950 ( c
UL us
)
Sikkerhet
Laser EN60825
Advarsel: Laserprodukt av klasse 1.
Advarsal: Stirr ikke på strålen.
Fare For Lynnedslag
Fare: Arbeid ikke på utstyr eller kabler i tordenvær.
Blokker ikke luftventilene
All strømtilførsel må komme fra adapteren.
Europe - EU
Benytt TÜV-godkjent AC-adapter på 12V DC, 500mA (millismpere)
Driftstemperatur: Dette produktet er konstruert for bruk i maksimum romtemperatur på 40 grader celsius.
Alle Land: Produktet må installeres i samsvar med de lokale og nasjonale elektriske koder.
32
AT-MC100 Series Installation Guide
! 1
! 2
! 3
! 5
! 6
! 7
! 8
! 4
! 9
! 10
! 11
! 12
Padrões: Este produto atende aos seguintes padrões.
Emissão De Interferência De
Imunidade EN50082-1 1997
Advertência: Este produto requer a utilização de cabos blindados para cumprimento dos standards de limites de emissão e imunidade. Se o produto for utilizado com cabos não blindados, o utilizador poderá necessitar de tomar medidas para correcção de problemas de interferência, por sua própria conta.
Segurança Eléctrica EN60950 (TUV), UL1950 ( c
UL us
)
Segurança
Laser EN60825
Aviso Produto laser de classe 1.
Aviso Não olhe fixamente para o raio.
Perigo De Choque Causado Por Raio
Perigo: Não trabalhe no equipamento ou nos cabos durante períodos suscetíveis a quedas de raio.
Não bloqueie as aberturas de ventilação
Use somente o adaptador fornecido para alimentação elétrica do hub.
Europe - EU
Use um adaptador de corrente alternada com saída DC de 12V e 500mA em conformidade com as especificações da TÜV.
Temperatura De Funcionamento: Este produto foi projetado para uma temperatura ambiente máxima de 40 graus centígrados.
Todos Os Países: Instale o produto de acordo com as normas nacionais e locais para instalações elétricas.
33
Translated Electrical Safety and Emission Information
! 1
! 2
! 3
! 4
! 5
! 6
! 7
! 8
! 9
! 10
! 11
! 12
Estándares: Este producto cumple con los siguientes estándares.
Emisión RFI EN55022 Clase B
Inmunidad EN50082-1 1997
Advertencia: Este producto exige cables protectores para ajustarse a las normas de emisión e inmunidad. Si se utiliza con cables sin protección, el usuario tendrá que correr con los gastos por las medidas a tomar en caso de problemas de interferencias.
Seguridad Eléctrica EN60950 (TUV), UL1950 ( c
UL us
)
Seguridad
Laser EN60825
¡Advertencia! Producto láser Clase 1.
¡Advertencia! No mirat fijamente el haz.
Peligro De Rayos
Eligro: No realice ningun tipo de trabajo o conexion en los equipos o en los cables durantetormentas electricas.
No bloquee las aberturas para ventilacion
La energía para el dispositivo central o "hub" debe provenir únicamente del adaptador.
Europe - EU
Utilizar un adaptador de corriente alterna autorizado TÜV de 12 voltios de corriente continua y 500 miliamperios.
Temperatura Requerida Para La Operación: Este producto está diseñado para una temperatura ambiental máxima de 40 grados C.
Para Todos Los Países: Monte el producto de acuerdo con los Códigos
Eléctricos locales y nacionales.
34
AT-MC100 Series Installation Guide
! 5
! 6
! 7
! 8
! 9
! 10
! 1
! 2
! 3
! 4
! 11
! 12
Standarder: Denna produkt uppfyller följande standarder.
Radiostörning EN55022 Klass B
Immunitet EN50082-1 1997
Varning! Denna produkt kräver skärmade kablar för att uppfylla standardkraven för emission och immunitet. Om den används med oskärmade kablar kan användaren vara tvungen att vidta åtgärder på egen bekostnad för att åtgärda störningsproblemet.
Elsäkerhet EN60950 (TUV), UL1950 ( c
UL us
)
Säkerhet
Laser EN60825
Varning! Laserprodukt av klass 1.
Varning! Laserstrålning när enheten är öppen.
Fara För Blixtnedslag
Fara: arbeta ej på utrustningen eller kablarna vid åskväder.
Blockera inte luftventilerna
Endast anslutningsenheten får vara kraftkälla till centralen.
Europe - EU
Använd en växelströmsanslutningsenhet licensierad av TÜV. Likström 12V,
500mA.
Driftstemperatur: Denna produkt är konstruerad för rumstemperatur ej
överstigande 40 grader Celsius.
Alla Länder: Installera produkten i enlighet med lokala och statliga bestämmelser för elektrisk utrustning.
35
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 3 Electrical Safety and Emission Compliance
- 7 Table of Contents
- 9 Welcome to Allied Telesyn
- 9 Where to Find Web-based Guides
- 9 Document Conventions
- 10 Contacting Allied Telesyn Technical Support
- 10 Online Support
- 10 Telephone Support
- 10 E-mail Support
- 11 Returning Products
- 11 Management Software Updates
- 11 For Sales or Corporate Information
- 12 Tell Us What You Think
- 13 Chapter 1
- 13 Overview
- 14 Key Features
- 15 Status LEDs
- 15 MDI/MDI-X Button
- 16 Link Test/MissingLink Button
- 17 Auto-negotiation Button
- 18 External AC/DC Power Adapter
- 19 Network Topologies
- 19 Standalone Topology
- 20 Back-to-Back Topology
- 21 Chapter 2
- 21 Installing the Media Converter
- 21 Verifying the Package Contents
- 21 Planning the Installation
- 23 Reviewing Safety Precautions
- 24 Installing the Media Converter
- 26 Warranty Registration
- 27 Chapter 3
- 27 Troubleshooting
- 27 Troubleshooting Guidelines
- 29 Loopback Test
- 31 Appendix A
- 31 Technical Specifications
- 31 Physical
- 31 Environmental
- 31 Electrical Rating
- 32 Agency Certifications
- 32 Fiber Optic Port Specifications
- 35 Appendix B
- 35 Translated Electrical Safety and Emission Information