Description - PN88 Matrix
The PageNet88 is a matrix switching system which allows any one of up to 8 remote paging microphones to page into any combination of up to 8 output zones. The system also allows any one of up to 4 program inputs to be fed to any or all of the 8 output zones. An emergency input is also provided.
The PageNet88 matrix is an attractive, slim-line, 2 RU steel cabinet which may be desk or 19” rack mounted. It includes inputs for each of the 8 remote PageNet88M microphone stations
(line level signal and control) and a line level output to each of the 8 output zones. Also included are inputs for the 4 program sources (CD, tape, tuner etc) with associated level trim pots and an input for an emergency signal such as from an EWIS control panel or priority message system. Included internally are alert and evacuate signal tone generators (defeatable) which may be activated remotely by simple contact closure.
The PageNet88 allows for total control over the operation of each of the 8 output zones. Each of the 8 output zones is equipped with controls for program selection (via 4 interlocking pushbuttons), microphone level, program level, bass, treble and master output level - as we say, total control. Each zone also has an associated push button to allow the zone to be included or excluded from receiving paging announcements. The PageNet88 may be powered via AC mains (240 volts or 110 volts on special order) or DC, 12 - 24 volts.
Description - PN88M Paging Microphone
Each PageNet88M microphone station includes 8 zone select buttons (with associated zone status LEDs), a ‘Zone Page’ button, an ‘All Page’ button, a ‘Clear’ button and a ‘System Busy’ LED. Also included is a gooseneck microphone and microphone sensitivity control. A bass cut switch is located on each PageNet88M to reduce ‘booming’ in high noise areas if required. The PageNet88M is housed in an attractive and heavy duty case and may be desk or wall mounted.
When a page is made, a pre-announce tone (defeatable) will sound in each of the output zones selected. Any program material playing in to the zone(s) selected will be ducked for the duration of the page. Microphone #1 has priority over Microphones
#’s 2-8 while Microphone #2 has priority over Microphones #’s 3-8. While the system is being used (busy), a large red LED will flash on all
PageNet88M microphone stations.
PageNet is available now and is a very cost effective and simple way of solving what can be a frustrating, customised and expensive audio installation problem.
Frequency Response
Total Harmonic Distortion
Signal To Noise Ratio
Input Sensitivity (Program Inputs)
50Hz - 15kHz (± 3dB)
0.1%
-70dB
100mV
Input Impedance (Program Inputs)
Input Connection
22K Ohms
Program Inputs: Dual RCA sockets with trim control;
Zone Mics: Line Level XLRs; Zone Control: 15 pin standard ‘D’ connector
Outputs
Zone Input
Power Sources
Zone Outputs: 600 Ohm line level XLR (1.5V RMS)
100mV
AC: 240V - 50Hz or 110V - 60Hz (special order),
3 pin IEC connector; DC: 12-24V DC
Power Consumption
Dimensions/Weight
Control Cable & Connector Requirements
25 Watts (maximum)
88mm H x 480mm W x 200mm D (Chassis dimensions only). 6kg
Hartland HCE316 or equivalent;
15 pin standard ‘D’ connectors
ARCHITECTURAL AND ENGINEERING SPECIFICATIONS
The Zone Paging System shall consist of an 8 zone matrix switcher and up to 8 zone paging microphones. The switcher shall have facilities to enable up to 4 program inputs to be assigned to any of the
8 outputs via simple front panel push buttons. The switcher shall include program select, program level, mic level and master level controls for each zone. Additionally, any zone shall have the ability to be removed from the paging function via front panel buttons. The switcher shall also include a bell tone and evacuation tone as well as a defeatable pre-announce chime. An emergency input shall be provided on the rear panel.
The zone paging microphones shall have 8 zone buttons, each with a status LED, a zone page button, all page button and a clear button. A busy LED shall be included on each zone microphone. One microphone shall have overall priority, a second shall have secondary priority. All microphones shall have priority over the program sources.
The Zone Paging System shall be an Australian Monitor Installation Series PageNet88.
Engineered and Distributed By AUDIO TELEX COMMUNICATIONS PTY LTD (
ABN 78 001 345 482
), 149 Beaconsfield Street, Silverwater, Sydney, NSW, 2128 Australia
NSW Tel: (02) 9647 1411 Fax: (02) 9648 3698 VIC Tel: (03) 9890 7477 Fax: (03) 9890 7977 QLD Tel: (07) 3852 1312 Fax: (07) 3252 1237 WA Tel: (08) 9228 4222 Fax: (08) 9228 4233
TAS Tel: (03) 6228 6373 Fax: (03) 6278 1063 SA Tel: (08) 8352 4444 Fax: (08) 8352 4488 Export Enquiries: [email protected] Website: www.australianmonitor.com.au
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project