Majestic STR33 Homeowner's Installation And Operating Manual

Add to my manuals
24 Pages

advertisement

Majestic STR33 Homeowner's Installation And Operating Manual | Manualzz

STR Series

Woodburning Fireplace

Homeowner's Installation and Operating Manual

For Models:

STR33

STR36

STR42

For use in U.S./Canada

Underwriter's Laboratories

Report No. MH7603

���

���������

DO NOT DISCARD THIS MANUAL: Retain for future use.

7412961 12/08 Rev. 19

2

STR Series Woodburning Fireplaces

Safety Information

PLEASE READ THIS MANUAL BEFORE INSTALLING AND USING FIREPLACE.

IMPORTANT: Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible fire hazard and will void the warranty.

Description

The STR Series fireplaces are multi-side solid fuel, woodburning fireplaces. These are radiant models only and include a preinstalled outside air kit.

Precautions

Majestic Fireplaces and component parts have been highly tested and will operate safely when installed in accordance with instructions provided in this manual.

Carefully read and understand all instructions before beginning installation.

If you notice any damage to fireplace or component parts, immediately report damage to your Majestic Fireplaces dealer.

Only use MHSC components or the warranty will be voided and a fire hazard may be created.

MHSC warranty will be voided by and MHSC disclaims any responsibility for the following actions:

Installation by any other than a qualified installer, preferably NFI or WETT (Canada) certified.

Installation of any damaged fireplace or chimney component;

Modification of fireplace, chimney assembly or any component parts thereof; (except for chase flashings as detailed in the Chimney Top installation instructions).

Installation other than as instructed by MHSC; or

Installation and/or use of any component part not manufactured or approved by MHSC in combination or assembly with a Majestic Fireplaces fireplace system, notwithstanding any independent testing laboratory or other third party approval of such component parts or accessory.

Any such action may possibly cause a fire hazard.

Consult local building codes to ensure that you are in compliance before installing the fireplace.

Fireplaces must be vented to the out-of-doors.

Do not obstruct or modify air inlets/outlets in any manner.

Do not install combustible materials on any of the black fireplace surround.

Burn only solid wood fuel or gas logs.

Do not install a solid fuel burning insert or other products not specified for use with this fireplace.

Proposition 65 Warning: Fuels used in gas, woodburning or oil fired appliances, and the products of combustion of such fuels, contain chemicals known to the State of California to cause cancer, birth defects and other reproductive harm.

California Health & Safety Code Sec. 25249.6

WARNING: Check with your electronics manufacturer before installing a television or other electronic device above this fireplace.

Drafts

The fireplace should not be located in areas that create drafts (ie: frequently opened doors and central heating air inlets/outlets) that hamper the normal flow of air into the fire.

Gas Logs

If you plan to install a gas log, the gas line should be installed before framing the fireplace. The gas line must be installed by a certified gas line installer.

STR33 / STR36 / STR42

Listed

UL 127 / ULC-S610

Standard for Factory Built Fireplaces

Table of Contents

Safety Information . . . . . . . . . . . . . . . . . . 2

Specifications and Framing . . . . . . . . . . 3

Parts Identification . . . . . . . . . . . . . . . . . 4

Chimney Requirements . . . . . . . . . . . . . 6

Planning Information . . . . . . . . . . . . . . . . 7

Installation . . . . . . . . . . . . . . . . . . . . . . . 8

Replacement Parts . . . . . . . . . . . . . . . . 20

Accessories . . . . . . . . . . . . . . . . . . . . . 22

7412961

Framing Width

Will be 24" Minus

2 x (Drywall Thickness)

36"

18���"

12"

STR Series Woodburning Fireplaces

STR Series Woodburning Fireplace

F G

24" Total

Unit Width

12"

��

D

E

C

7���"

21"

37"

STR33 STR36 STR42

A 33" 36" 42"

838mm 914mm 1067mm

B 37" 40" 46"

940mm 1016mm 1168mm

C 18���" 20" 23"

470mm 508mm 584mm

D 49���" 49���" 53���"

1267mm 1267mm 1368mm

E 52���" 52���" 56���"

1340mm 1340mm 1442mm

F 11" 11" 13���"

279mm 279mm 343mm

G 8" 8" 11"

203mm 203mm 279mm

J 26���"� � 29 ����"� 35����"

680mm 741mm 894mm

J

14���"

9���"

12"

Outside

Air

Gas Line Access

Fig. 1 STR Series specifications and framing.

A

B

7���"

FP702A

STR SPECS

9/24/98 added note 9/21/99

7412961 3

STR Series Woodburning Fireplaces

STR Series Woodburning Fireplace

Outer Collar

Flue Collar Header Standoffs

Outer

Dome

Gas Line

Access

Outside Air

Access

Metal Safety Strips, shown not in place

(1, 2, or 3 Pieces)

Fig. 3 STR Parts Identification.

Ledge Brackets

Flue Damper Control

(Inside)

Brick liner on

Sides and Hearth

Gas Line Knock-out

(Both Sides)

Air Inlet

Outside Air

Control

Wood Grate

Firebox

Hearth

FP701a

A

B

FP701a

STR Parts ID

FP1545

STR33

STR36

STR42

Front/Back Width Side Width

FP1545

Fig. 3a Hearth dimensions.

A hearth dimensions

1/05 29"

(737 mm)

35"

(889 mm)

B

17¹⁄₈"

(435 mm)

17¹⁄₈"

(435 mm)

17¹⁄₈"

(435 mm)

4 7412961

Chase Installation

Insulation methods shown are optional for cold climate, not a requirement for unit operation.

Batt Insulation

(cut out around firestop)

Firestop

Ceiling Level

Outer Dome

Refer to Figures 21 and 26 for clearance information.

Ledge Brackets

Nailing Flange

Gas Access

(both sides)

Outside Air Cover Plate

Fig. 4 Fireplace and chase parts identification.

7412961

STR Series Woodburning Fireplaces

Termination Cap

Storm Collar

Pan Flashing

Draftstop

Finish Wall

Surround

Screen

Grate

Firebox

Outside Air

Control

FP704

STR (from FP528)

7/28/98 FP704

5

STR Series Woodburning Fireplaces

Chimney Requirements - Offset Installations

CHIMNEY FLUE EXIT

OFFSET

RISE

CHIMNEY

SECTION

ELBOW

B

RETURN

ELBOW

A G

G

D

E

6 FT.

RISE

OFFSET

ELBOW

C

OFFSET

H

RETURN

ELBOW

B

30˚

ELBOW

H

HEARTH

FLOOR

Example 1 Example 2

Notes: G + H cannot exceed 20 feet.

Air Space Clearances:

SK8 (2-wall) = 1¹⁄₂" , and 11CF (2-wall) = 2"

Illustration Key

The following safety rules apply to offset installations (letters correspond with illustration above):

A. Height of the chimney is measured from the hearth to the chimney exit.

Maximum:

Minimum:

STR Series

90'0"

Without Elbows

With 2 Elbows*

With 4 Elbows*

15'6"

17'6"

21' 0"

B. Do not use more than 4 elbows per chimney.

Attach the straps of the return (top) elbow to a structural framing member.

The offset (first) elbow of any pair does not have straps.

Example 3

FP720

FP720

(45˚ in Canada) from the vertical plane in any installation*.

D. The maximum length of the angled run of the total chimney system is 20 feet. (G plus H cannot exceed 20 feet.)

E. A chimney support (Models TCS8A or

11CS) is required every 6 feet of angled run of chimney. Chimney supports are required for every 30 feet and 60 feet (SK8

& CF11 pipe) of vertical chimney height above the hearth.

Determine the offset distance of your chimney arrangement from the centerline of the fireplace to the centerline of the chimney where it is to pass through the first ceiling.

NOTE: This offset distance may not be your full offset distance. See Examples 2 and 3.

* In Canada, two (2) SK845 are allowed.

Fig. 5 Chimney system requirements.

6

FP282

IWF282

MBUF

Offset

5/26/96

1' 1¹⁄₂' 3' 4'

0 0 0 0 0 3" 11"

1 0 0 0 0 8¹⁄₄" 20"

0 1 0 0 0 11¹⁄₄" 25¹⁄₄"

2 0 0 0 0 13¹⁄₂" 29¹⁄₄"

1 1 0 0 0 16¹⁄₂" 34¹⁄₄"

0 0 1 0 0 20¹⁄₄" 40³⁄₄"

2 1 0 0 0 21³⁄₄" 43¹⁄₂"

0 0 0 1 0 26¹⁄₄" 51¹⁄₄"

0 1 1 0 0 28¹⁄₂" 55¹⁄₄"

1 0 0 1 0 31¹⁄₂" 60¹⁄₄”

0 1 0 1 0 34¹⁄₂" 65¹⁄₂"

0 0 2 0 0 37¹⁄₂" 70³⁄₄"

1 1 0 1 1 41¹⁄₂" 77³⁄₄"

0 0 1 1 1 45" 83³⁄₄"

0 1 2 0 1 47¹⁄₄" 87¹⁄₂"

0 0 0 2 1 51" 94"

0 1 1 1 1 53¹⁄₄" 98"

0 0 3 0 1 56¹⁄₄" 103¹⁄₄"

0 1 0 2 1 59¹⁄₄" 108¹⁄₂"

0 0 2 1 1 62¹⁄₄" 113¹⁄₂"

0 1 3 0 1 64¹⁄₂" 117¹⁄₂"

0 0 1 2 1 68¹⁄₄" 124"

0 1 2 1 1 70¹⁄₂" 128"

0 0 0 3 1 74¹⁄₄" 134¹⁄₂"

0 1 1 2 2 78" 140³⁄₄"

0 0 3 1 2 81" 146"

0 1 0 3 2 84" 151¹⁄₄"

0 0 2 2 2 87" 156¹⁄₂"

0 1 3 1 2 89¹⁄₄" 160¹⁄₄"

0 0 1 3 2 93" 166³⁄₄"

0 1 2 2 2 95¹⁄₄" 170³⁄₄"

0 0 0 4 2 99¹⁄₄" 177³⁄₄"

0 1 1 3 2 101¹⁄₄" 181³⁄₄"

0 0 3 2 2 104¹⁄₄" 186¹⁄₄"

0 1 0 4 2 107¹⁄₄" 191¹⁄₂"

0 0 2 3 2 110¹⁄₄" 196³⁄₄"

0 1 3 2 3 114" 203¹⁄₄"

0 0 1 4 3 117³⁄₄" 209³⁄₄"

0 1 2 3 3 120" 213¹⁄₂"

0 0 0 5 3 123³⁄₄" 220"

7412961

STR Series Woodburning Fireplaces

Planning Information

Preplanning an installation is very important to ensure safety and to save time and money. An installer must predetermine where a fireplace will be set and how the chimney system will be run.

NOTE: STR33/36 models use MHSC SK8 (2-wall) chimney systems. STR42 Fireplace uses only model

11CF chimney system.

Mounting the Fireplace

A fireplace may only be mounted on the following surfaces:

1. A flat combustible surface.

2. A raised wooden platform.

3. A concrete block or other solid object placed beneath each of the four (4) corners of the fireplace.

The fireplace must be spaced 1/2" (13 mm) from a combustible back wall and 1/2" (13 mm) from a combustible side wall or support. (Page 14, Fig. 20)

Planning the Chimney Run

Determine how the chimney will be run, length of run and chimney components required to complete the job. (Fig. 6) Never install a chimney below minimum heights.

The Ten Foot Rule

Major U.S. building codes specify a minimum chimney height above the roof top. The “Ten Foot Rule” is a fire safety rule and not a draft rule. To ensure proper draft, it is recommended that you always meet or exceed the

“Ten Foot Rule,” especially when installing a termination on a high pitch roof. (Fig. 7)

The key points of the "Ten Foot Rule" are:

1. If the horizontal distance from the chimney to the peak of the roof is 10' (3m) or less, the top of the chimney must be at least 2' (610mm) above the peak of the roof, but never less than 3' (914mm) in height above the highest point where it passes through the roof.

2. If a horizontal distance from the chimney to the peak of the roof is more than 10' (3m), a chimney height reference point is established on the surface of the roof a distance of 10' (3m) from the chimney in a horizontal plane. The top of the chimney must be at least 2' (610mm) above the reference point, but never less than 3' (914mm) in height above the highest point where it passes through the roof.

0 To 10'

LT

L1

L1

MODEL SK &

MODEL 11 CF

2 WALL CHIMNEY

SK81 / 11CF1

SK818 / 11CF18

SK83 / 11CF3

SK84 / 11CF4

TOTAL

LENGTH

(LT)

����� "

����� "

����� "

����� "

INSTALLED

LENGTH

(L1)

����� "

����� "

����� "

����� "

FP705

Fig. 6 Installed lengths of chimney sections.

In planning a chimney system, it is important to know:

1. The height of a chimney is measured from the hearth to the exit point on the termination.

2. A chimney cannot be offset more than 30° from a vertical plane.

3. A chimney may run straight up or it may be necessary to offset it to avoid obstructions.

4. The maximum length of an angled run (total chimney system) is 20' (6m).

5. No more than 2 offsets (4 total 30˚ elbows in U.S./or

2 total 45° elbows in Canada) per fireplace may be used.

6. A guy wire stabilizer is required for chimneys extending more than 6' (1.8m) above a roof line.

2' Min.

3'

Min.

Reference

Point

0 To 10'

2' Min.

Fig. 7 Ten Foot Rule illustration.

AC246

4/1/96

AC246

7412961 7

8

STR Series Woodburning Fireplaces

Chimney Supports

The chimney system is supported by the fireplace for vertical chimney heights less than 20' (6 m) above the hearth. Chimney supports are required if the vertical height exceeds 20' (6 m). Locate chimney supports at ceiling holes or other structural framing at 20' (6m) heights. Spacing between chimney supports must not exceed 20' (6 m). Use Chimney Support Model SKCS8 for SK8 chimney, and Model 11CS for 11CF chimney.

(NOTE: the chimney support can not be mounted

directly to the fireplace.) Support provided by elbow straps fulfills the support requirement only if they are spaced as previously described. (A chimney support is

2¹⁄₂" (64 mm) long when installed.)

Angled chimney runs require a support every 6' (1.8 m) in addition to the elbow straps. Chimney supports are used for this function. (Fig. 9)

Chase Installation

A chase is a vertical box-like structure which encloses the fireplace and/or chimney. Chases are typically built on the outside of the house with fireplace opening cut into the outer wall of a room. (Page 5, Fig. 4)

If you need help in determining fireplace location or how the chimney system should be run, contact your Majestic dealer for assistance.

Installation

Insulating Fireplace Enclosure for Cold

Climates

If you live in a cold climate, it is not required but

highly recommended that you insulate fireplace enclosure to eliminate cold air penetration as much as possible.

Insulate base of fireplace with a non-combustible insulation rated for a minimum of 300°F. Insulating is very important for outside wall installations over a concrete slab. If fireplace is installed on a platform, insulation should be placed on top of the platform

before fireplace is set. (Fig. 9)

When a fireplace is installed in a chase or on a outside wall, enclosure should be treated like any outside wall in a home. Insulation should be installed on the inside wall as well as the outside wall(s). In a chase, it is also a good idea to install a firestop at the first ceiling level above the fireplace and enclose the chase with sheeting material. Insulation may then be installed above sheeting material to assure the space around the fireplace is totally protected.

(Fig. 4)

When installing the chimney, DO NOT caulk between outer pipe and firestop. It is vital that some air be allowed to flow through this very thin gap.

CAUTION: WHEN INSTALLING A FIREPLACE

IN AN INSULATED ENCLOSURE, BE SURE ALL

REQUIRED AIR SPACES ARE MAINTAINED. (Page

14, Fig. 20)

Chimney Support Strap

SKCS8

FP284

Fig. 8 Chimney support installation

IWF284

MBUF

5/25/96

7412961

Framing

Framing can be constructed before or after the fireplace is set in place, however, most installers build the frame before setting the fireplace.

Frame fireplace with 2 x 4 lumber or heavier materials. Refer to framing dimensions in Figures 1, 2, 3 or 4 for basic fireplace specifications. Headers and support studs must be turned on end as illustrated on Page 5,

Figure 4.

NOTE: Framing should be positioned to accommodate wall covering and fireplace facing material. Maintain

1/2" (13 mm) air space between the outer dome and any combustible framing materials that may be supported by the ledge brackets. Refer to Figures 20 and 26 for details.

Hard, Flat

Surface

Insulation

Plateform

Fig. 9 Insulating between platform and fireplace.

FP706

STR/CVR

6/1/98

FP706

STR Series Woodburning Fireplaces

Chimney Set-up

Since you have already preplanned the chimney run, you should know exactly how the installation is to be accomplished — how much pipe is required, the number of elbows, if any, and type of termination to be used.

CAUTION: REPORT TO YOUR DEALERS ANY

PARTS DAMAGED IN SHIPMENT, SPECIFICALLY

CHECK THE END CONNECTION OF CHIMNEY SEC-

TIONS AND ELBOWS.

NOTE: STR33/36 models use MHSC SK8 (2-wall) chimney systems. STR Fireplaces use only model 11CF chimney system.

Straight-Up Chimney Installation

To locate the centerline of the flue put the fireplace in final position and place a plumb bob from the ceiling to the center of the fireplace flue collar. Mark this spot on the ceiling. Draw a line through that mark to either side of the firebox and indicate dimension X to locate the side wall framing. (Fig. 10) Be sure to observe clearance requirements for side and parallel combustible walls as noted in Page 16, Figure 23.

Offset Installation

In order to clear an obstruction, it may be necessary to offset chimney from vertical. This is accomplished by using MHSC elbows. Use the 30° Offset Elbow table on

Page 6 to determine proper offset and parts required.

Each offset requires two (2) elbows. The second elbow is equipped with support straps. It is very important to install the second elbow in each offset as close to the ceiling or support as possible so that the elbow straps can be secured to framing members to help support the weight of the chimney.

Determine offset distance of your chimney arrangement from centerline of fireplace to centerline of chimney where it is to pass through ceiling.

Locate center point of the chimney on ceiling as though a straight up chimney arrangement is to be used.

Measure your offset dimension from the chimney center point on the ceiling.

7412961 9

STR Series Woodburning Fireplaces

Actual Centerpoint

Chimney

Centerline

X

Side of STR

Plumb Line

Plumb Bob

Imaginary

Centerpoint

Model X =

STR33 19" (483 mm)

STR36 20¹⁄₂" (521 mm)

STR42 23¹⁄₂" (597 mm)

Framing the Ceiling Hole

Frame the ceiling chimney hole as shown in Figure

12. It is good practice to use framing lumber that is the same size as the ceiling joists; this is a requirement at attic level.

The following table gives firestop spacer model numbers:

Size of Chimney

8" Flue

"SK" Series

11" CF 2-Wall

Angle of Chimney at Ceiling

Vertical

SKFS2A

14¹⁄₂" x 14¹⁄₂"

(368 x 368 mm)

FS2A

17¹⁄₂" x 17¹⁄₂"

(445 x 445 mm)

30°

SKFS6A

14¹⁄₂" x 25¹⁄₂"

(368 x 648 mm)

FS6A

17⁷⁄₈" x 29⁵⁄₈"

(454 x 753 mm)

Fig. 11 Ceiling chimney hole sizes necessary for installing firestop spacer.

The inside dimension of the frame must be the same as the hole size selected from Figure 12 in order to provide the required air space (1¹/₂" (38 mm)with SK8,

2" (51 mm) with Model 11CF) between the outside diameter of the chimney and the edges of the framed ceiling hole.

Fig. 10 Locate centerline of chimney with plumb line.

FP707

Ceiling Chimney Hole/

Possible Obstructions

The size of the hole in ceiling will vary with the angle at which the chimney passes through ceiling.

Drive a nail up through ceiling at marked chimney center point. Go to floor above and see where hole will be possible obstructions are located...i.e. wiring, plumbing etc... If necessary, re-position chimney and/or fireplace to avoid obstructions.

Cutting the Hole

Cover fireplace collar opening and cut proper sized chimney hole in chimney. The SK8 pipe allows you to run pipe through a typical 16” on center joist without cutting joists.

Existing

Ceiling

Joists

New Framing

Members

A/B A/B

Chimney Hole

A "SK8" Series framing = 14���" X 14���" (368 x 368mm)

B 11CF framing = 17���" X 17���" (445 x 445mm)

FP551A

Fig. 12 Typical frame for ceiling chimney hole.

FP551A

BR/BC

9/23/98

10 7412961

STR Series Woodburning Fireplaces

Positioning, Safety Strips,

Securing the Fireplace

Slide fireplace into position.

Lift the fireplace front slightly and slide the metal safety strips under front bottom edge about 1¹⁄₂" (38mm), allowing the remainder to extend in front of firebox.

Overlap strips at least 1/2" (13 mm) to provide a positive joint. (Flat safety strips are packed with fireplace.) (Fig. 13)

Safety strips are used to ensure that any combustible materials in front of the fireplace are protected even though a noncombustible hearth extension is required.

If fireplace is to be elevated above the floor, a “Z” shaped metal safety strip must be fabricated and used to protect combustible surfaces in front of the fireplace.

This “Z” shaped safety strip is not provided but must be fabricated of metal with each horizontal leg at least 1¹⁄₂"

(38mm) wide and equal in length to the metals strips provided with the fireplace.

NOTE: Safety strips are not required over non-combustible floors where all supports at the base of the fireplace are noncombustible.

Eight (8) nailing flanges are supplied with the fireplace

(found on the fireplace hearth). To level the box and secure it firmly in place, remove the nailing flanges from the hearth and install at the sides of the fireplace as shown in Figure 14.

Outside Air Kit

An outside air kit damper is installed in all STR Series

Fireplaces. If desired, or if local codes mandate the use of an air kit, then an AK-MST is required to complete the installation (from air kit to the outdoors). If the outside air kit is to be used, the AK-MST Air Termination Kit

MUST be installed BEFORE the fireplace is enclosed.

Refer to the AK-MST instructions for field installation.

The outside air kit control is located in the lower left hand side of the fireplace behind the screen panel. (Fig.

15) To operate, simply lift up to close or push down to open .

Model STR

Fig. 14 Fasten fireplace in position.

FP709

7/28/98

STR/CVR

Metal Safety

Strips

(1, 2 or 3 pieces)

FP708

����

"

(38mm)

���

" (13mm)

Min. Overlap

Fig. 13 Safety strip installation.

Fire-

Place

Plat-

Form

"Z"

Safety

Strip

(not supplied)

Hearth Ext.

WF708

STR/CVR

5/29/98

Standoffs

Side-Nailing

Flanges

FP709

7412961

CLOSED

OPEN

Fig. 15 Outside air operation.

WF 710

OUTSIDE AIR LEVER

WOOD FIREPLACES

5/28/98

FP710

11

STR Series Woodburning Fireplaces

Installing the Chimney System

Start by attaching the first chimney section to the collar on top of the fireplace.

Install the pipe as pictured in Figure 16. When you get a good lock, you will hear the pipe clearly snap together. Once sections are snap-locked in place, it is extremely difficult to get them apart. Make sure the pipe is firmly snapped and locked together as each pipe section is mounted.

When installing elbows, only outer pipe will snap- lock. Middle pipes simply slide into position. Be sure to always attach straps on upper elbow to a structural framing member. (Fig. 17)

Continue installing the pipe as required until pipe is installed up through the ceiling. At this point, you must install a firestop spacer. Refer to Figure 18 for appropriate spacer orientation.

Pipe Section

UP

Pipe Rim

Pipe

Rim

Hem

Lance

FP711

Fig. 16 Install pipe, listening for the snap-lock to fasten.

Installing the Firestop Spacer in the Ceiling Hole

Elbow Strap

Support Structure

A firestop spacer is used to keep pipe spaced properly and required for safety.

Nail the firestop spacer (at each corner) to the framing members of the ceiling hole. NOTE: A firestop spacer is not required at the roof.

Hole sizes listed in Figure 12 for angled firestop spacers provide minimum required air space to chimney pipe for ceiling thickness up to 8" (203 mm). When combined thickness of ceiling material, ceiling joists and flooring material exceeds 8" (203mm), adjustments must be made in framing to assure that minimum air spaces to chimney are maintained.

Proper Firestop Spacer Installation

Angled Strap

WF711

5/28/98

Elbow Strap

(must be tight)

Ceiling

Hole Framing

Angle Firestop

FP270/271

Chimney Support

Strap

(must be tight)

FP270/271

Fig. 17 Attach straps to a structural framing member.

Figure 18 shows different installation procedures for both an area that is an attic and an area that is not an attic.

If the area above the ceiling is not an attic, position the firestop spacer with the flange on the ceiling side and the angled portion extending up into the hole.

Attic Installation

If the area above the ceiling is an attic, position the firestop spacer with the flange on the top of the framed hole and the angled portion extending down into the hole.

Fig. 18 Installing firestop spacer.

Nails (4)

Firestop

Spacer

Joist

NOTE: If the attic insulation shield is used, the firestop is not required in the attic installation.

Ceiling Installation

Joist

Firestop

Spacer

Nails (4)

FP593

12 7412961

SR/C

11/20/97

Firestop spacers are not available for nor are they required on vertical walls.

DO NOT put any sealant around the area where the outer pipe slides through the firestop spacer. If you seal this area, it may cause a fire hazard.

Canadian Requirements for Insulation Shield

In Canada, an attic insulation shield is required to prevent attic insulation from contacting the chimney section. NOTE: If the attic insulation shield is used, the firestop is not required in the attic installation. Framing dimensions for the chimney hole should measure 14¹⁄₂" x 14¹⁄₂" (368 x 368 mm)(SK8). (An attic shield MUST be installed on top of attic joists (above the floor level).

(Fig. 19)

NOTE: In the U.S., it is a good idea, although not always required, to install an attic insulation shield where blown-in insulation is planned to be used in the attic.

Install the attic insulation shield with the flanges on its base extending down into the framing hole. Nail each corner of attic insulation shield to the framing members of the ceiling hole using 8d nails. Attic shields are not required at the roof.

Attic Insulation Shield

Nails

(4 required)

Attic Joist

Base

Flanges

Ceiling

FP263

Fig. 19 Attic shield installlation (Canadian requirement).

Continue Installing Pipe to Complete Run

Continue attaching pipe sections to complete system to next level always being careful that the pipe is firmly snapped locked in place before proceeding to next pipe section.

Chimney Supports

If chimney supports are required, they are installed the same as elbows. Nail chimney support straps to adjacent structural framing, as shown on Figure 8, Page

8. Bend straps as necessary and make sure they are secure so they will support the weight of the chimney.

A chimney support is 2¹⁄₂" (64 mm) long when installed.

7412961

STR Series Woodburning Fireplaces

Consider this dimension when determining how many straight chimney sections are needed.

NOTE: Chimney supports are generally used in long runs in a chase installation. A chimney support can- not be mounted directly to the fireplace.

Additional Ceilings

If you encounter additional ceilings, repeat same steps required for first ceiling installation. Refer to firestop illustration on Page 12, Figure 18.

Penetrating the Roof

Run pipe to roofline. Since chimney system must be vented to the out-of-doors, you must use an approved termination.

If a chase is used, refer to the installation manual provided with the termination cap.

Locate Chimney Centerpoint on Roof

Use same procedure detailed in locating centerpoint of the flue system.

Drive a nail up through roof at the centerpoint. This will determine center point on outside of the roof.

Cut and Frame Roof Hole

Size of roof hole varies with the type of chimney termination installed. Refer to installation instructions provided with the chimney termination to find correct size of roof hole.

NOTE: The air space dimensions in this manual that pertain to model 11CF chimney pipe have been changed from 2" to 1" (51 - 25 mm) clearance for first joist space only. This change only applies to Majestic

Fireplaces models STR42 fireplaces. Because of framing concerns these models, and only these models, have been tested and approved at the reduced clearance. In all other cases the minimum air space referred to on the UL label on the 11CF pipe must be maintained. A special firestop is shipped with these units that will maintain the 1" (25 mm) clearance at the first joist. The chimney hole size for this firestop will be 15¹⁄₂"

(394 mm). Refer to Figure 18 for ceiling joist installation instructions.

There must be an air space (1¹⁄₂" (38 mm) with SK8 and

1" (25 mm) with 11CF) between outermost portion of chimney sections and any adjacent combustible surfaces. (Fig. 20) (Combustible surfaces include burnable materials such as: ceiling members, joists, flooring, combustible insulation and roof structures.)

WARNING: DO NOT PACK REQUIRED AIR SPACES

WITH INSULATION OR OTHER MATERIALS.

13

STR Series Woodburning Fireplaces

Mark an outline of the roof hole around the center of the point nail. NOTE: Hole dimensions given in the chimney top installation instructions are horizontal dimensions; therefore, the hole size must be marked on the roof accordingly.

Cover the opening of the installed chimney so debris cannot get into the system.

Cut and frame the hole. It is good practice to use framing lumber that is the same size as the rafters. Install the frame securely because the chimney top and flashing anchored to the frame must be able to withstand heavy winds.

Install Remainder of Chimney Sections

Since you have already preplanned the height of your termination according to the Ten Foot Rule, continue to install pipe to the predetermined height.

Check the chimney top installation instructions for details on how high above the roof top the chimney sections (all pipes) should extend.

Installing Top Housing or Termination

Follow the installation instructions provided with the chimney termination you have selected.

Installing Chimney In a Chase

Refer to Page 5, Figure 4 for an illustration of a typical chase installation.

CAUTION: Treatment of firestop spacers and construction of chase may vary with type of building. These instructions are not a substitute for local building codes.

You must check your local building codes to determine specific requirements for your city or state. NOTE:

Other building materials may be required in addition to

Firestop Spacers.

Finishing

CAUTION: All joints between the finished wall and the fireplace surround (top/sides) must be sealed with noncombustible material to prevent cold air leakage into the room. Only noncombustible material may be applied to the facing of the fireplace surround. (Black painted area) (Fig. 20)

Finish Wall

Finish the wall with material of your choice. Do not install a combustible mantel shelf less than 12"

(305 mm) above the front opening. Do not install a mantel face plate less than 6" (159 mm) from

top of fireplace opening. (Fig. 21) If a combustible material is used below a flat mantel shelf, consult your local building codes for minimum clearance from top of fireplace opening to bottom of mantel shelf.

Air Space Clearances

Combustible framing material MUST NOT penetrate AIR SPACE (shaded areas).

1���" (38mm)

������

������

�����������

����

��� " (13mm) air space

to sides

Front View

Wall

Shield

Standoff

����

� OUTER

DOME air space to sides

Side View

Firestop

��� " (13mm)

Air Space to Sides

Only noncombustible material may be applied as facing to the black fireplace surround.

0" Clearance to Floor

Hearth

Extension

FP717

Fig. 20 Minimum clearances to combustibles.

NOTE: No side wall protection is required for fireplaces installed at 45° to two (2) side walls (corner installation).

Adjacent combustible side walls that are within 16"

(406 mm) (STR33/36) and 20" (508 mm) (STR42) of fireplace opening must be protected with MHSC Wall

Shield Model SP40 or a specifically built wall shield described in Figure 20 & 24.

Often a decorative surround or vertical portion of the mantel is desired. If this is constructed of any combustible material, it must be within the safe zone indicated in Figure 24.

14 7412961

STR Series Woodburning Fireplaces

Mantel Clearance -

No Noncombustible Facing Material

Combustible

Mantel and Trim

12"

(305mm)

Min.

12"

(305mm)

Max.

1/2"

*

Mantel Clearance - with Noncombustible Facing Material

Fireplace

Front

Finished Wall

Standoff

2 x 4 Stud

Noncombustible Material

Header

Ledge Bracket

Combustible

Mantel and Trim

12"

(305mm)

Max.

12"

(305mm)

Min.

1/2"

6“

(159mm)

Min.

Fireplace Opening

Finished Wall

Standoff

2 x 4 Stud

Noncombustible Material

Header

Ledge Bracket

Noncombustible Facing Material

Fireplace

Front

Fireplace Opening

* Minimum width from top of surround to bottom of screen rail

Fireplace

Front

��� "

2 x 4 Stud

Finished Wall

Must be sealed with

noncombustible material

FP721

Fig. 21 Fireplace surround flush with finished wall.

STR/CVR

6/4/98 Face Plate

*

1���"

Ref.

* *

*12" (305 mm) from top of fireplace opening.

** 6" (159 mm) from top of fireplace opening.

(Noncombustible material must separate the black face surround of the fireplace and any combustible mantel material)

Fig. 22 Combustible mantel clearances.

7412961

Combustible materials are permitted within a shaded area shown in Figure 23, titled

Minimum Wall Clearances.

MA81 rev. 8/5/97

MA81

15

STR Series Woodburning Fireplaces

Side Wall Protection

All joints (top, bottom and sides) where wall or decorative facing material meets fireplace surround must be completely sealed with a noncombustible material.

(Figs. 20 and 24)

The special wall shield design described in Figure 20 is an alternate method of adding protection to side walls and can be used in place of the SP40 with the same wall clearances specified for the SP40. Rt must =1.85 minimum.

Examples of wall shield insulation:

1. Manville - CERAFORM 126, K=.27,

1/2 inches thick

2. MHSC - EH2416, K = .458,

1 inch thick required.

Minimum Dimensions to Side Walls

(for on-site construction)

Model

Parallel Side Wall to Movable Doors

Perpendicular

Side Wall to Firebox Opening

Air Space to Sides or Back of Unit

C

A

B

STR33

44"

STR36

44"

STR42

44"

(1118 mm) (1118 mm) (1118 mm)

16" 16" 20"

(406 mm) (406 mm) (508 mm)

1/2" 1/2" 1/2"

(13 mm) (13 mm) (13 mm)

C

Perpendicular Side Wall

B

C D

A

Parallel Side Wall

A

Fig. 23 Minimum firebox dimensions from combustible materials.

FP723

16

FP723

STR/CVR Side Wall clearances

6/21/98

7412961

B

C

STR Series Woodburning Fireplaces

Minimum Wall Clearances

Minimum Hearth Extension Dimensions

(for On-Site Construction)

WITH

Noncombustible

Surround Facing

4" BRICK

(Example material)

WITHOUT

Noncombustible

Surround Facing

Shaded area starts

1/2" away from edge of unit

4"

H

G G

E

F**

E

J

Side

Wall

Firebox

Opening D

C** A - Min. clearance to combustible perpendicular wall

B - Min. clearance to combustible perpendicular wall when using noncombustible wall shield*

Side

Wall

May install noncombustible decorative covering

OR .018" min. sheet metal

Seal cracks between the fireplace and hearth extension with noncombustible material

Fireplace

Hearth

STR33/36

STR42

Combustible material permitted within shaded area.

EH2416 insulation (minimum R Value = 1.09) between

decorative noncombustible rigid covering and combustible wall.

Minimum height and width is 40" x 40".

4" MIN.

Combustible

Floor

Minimum

Insulation

Value "R"

Safety strips must overlap

��� " minimum

A

16"

B

12"

C D E

48° 41° 18"

F

14"

G

8"

H

16"

J

48"

K

24"

(406 mm) (305 mm)

20" 12" 42° 35°

(457 mm) (356 mm) (203 mm) (406 mm) (1219 mm) (610 mm)

18" 14' 12" 20" 61¹⁄₂" 24"

(508 mm) (305 mm) (457 mm) (356 mm) (305 mm) (508 mm) (1562 mm) (610 mm)

FP714

Hearth Installation

A hearth extension is required to protect a combustible floor in front of the fireplace. Refer to Figure 24 for minimum dimensions and mounting detail.

Note: Hearth Extension must not cover the air inlet opening of a fireplace.

The hearth extension described in Figure 24 must be a durable noncombustible material with a minimum (total)

Rt value of 1.09; refer to Figure 25 for examples. The overall height (above a combustible floor), depth and width must be as indicated, with the extension centered to the fireplace opening.

The top of the insulation material must be covered with a noncombustible decorative covering or a piece of

.018” minimum sheet metal, to protect hearth extension material. (Fig. 24)

Secure the hearth extension to the floor to prevent shifting, using trim molding or other similar means at three (3) outer edges. Seal crack between the fireplace hearth and hearth extension with a noncombustible material. (Figs. 24 and 26)

7412961

STALLED IN ACCORDANCE WITH FIGURES 24 AND

25.

Alternate noncombustible materials may be used providing the (total) thermal resistance (Rt value) of the alternate material employed is greater than or equal to

R = 1.09. Thermal resistance (R) or thermal conductivity

(K), may be obtained from manufacturer of the material.

Factors are related by the formula K = 1/R.

T = given thickness

R = thermal resistance for a given thickness (T)

K = thermal conductivity

Noncombustible material with a lower R value may be used, provided thickness of material is sufficiently greater to maintain an equivalent (total) thermal resistance (Rt).

17

STR Series Woodburning Fireplaces

Example of Determining Hearth Extension

Equivalents

To determine the thickness required for any new material:

NEW K of new material (per inch) thickness required = X of listed thickness K of listed material (per inch) material

Example for Common Brick

T (new) = 5.0 / 0.458 x 0.50 in. = 5.46 in. (new required thickness).

COMMON MATERIALS AND FACTORS

MATERIAL K* R

MINIMUM

THICKNESS

EH2416

(MHSC)

0.458

1.09 0.50 in.**

Common Brick 5.0

0.10 5.46 in.**

R Value is for 1/2 inch.

* Units of K = BTU/SQ FT/HR/˚F/IN

** Thickness of Listed Material

Fig. 25 Hearth extension material factors.

FP533AD

Wall Covering

Noncombustible

FP533ADD

Addendum

6/1/99 djt

8/4/99 changed .2 to .1

/�"

Outer Dome surround and wall materials with noncombustible material.

Noncombustible

Covering

Do not notch at standoffs.

between

Outer Dome combustible materials

Side View between fireplace and hearth extension with noncombustible material.

Must be overlapped

���

" minimum.

FP719

Fig. 26 Finish wall treatments and gap sealing.

5/28/98

18

Seal Cracks Between Fireplace and Hearth

Extension with Noncombustible Material

Noncombustible

Material 7¹⁄₂"

Max. Thickness

Combustible

Floor

Lower Surround

Noncombustible

Material

1/4" Min. Thickness

Fireplace

Hearth

Safety Strips

Must be Overlapped 1/2" Min.

FP1170

Minimum Insulation

Value R-0.94

Fig. 27 Hearth extension dimensions.

Recessed Installation - STR33/36 Only

Noncombustible

Material

(if desired)

Minimum

36” (914 mm)

������

������������

A

��������������

Insulation with Minimum

R Value of 2.75

6”

(152 mm)

Minimum

Minimum

33”

(838 mm)

Maximum

10”

(254 mm)

2”

(51 mm)

Hearth Extension

2”

(51 mm)

A

Minimum .030 Thick Stainless Steel Plate

Insulation with Minimum R

Value of 2.75

Minimum .030

Thick Stainless

Steel Plate

Maximum

14”

(356 mm)

Hearth

Extension

FP1608

View A

NOTE: If noncombustible material is not used between the stainless steel plate and fireplace opening, the steel must be attached to the front of the unit a minimum of four (4) places on each piece with sheet metal screws no longer than 1/2".

������

������������������� combustible framing material.

����

7412961

Installing Line for Gas Logs

Majestic Fireplaces are designed to accept a 1/2"

(13 mm) gas line for installation of an approved gas appliance. (MHSC manufactures a wide variety of gas logs for use in Majestic fireplaces.)

Be sure to have the appliance installed in accordance with building codes.

Gas connection may enter from either left or right side of the fireplace.

Locate appropriate gas line in the outer casing of fireplace and remove insulation from gas line tube. (Fig. 29)

From inside the fireplace, locate the knockout on the firebrick -- be sure you are on the appropriate or "gas line" side of the fireplace. Using a flat bladed screwdriver or small chisel and hammer, carefully tap around the knockout until it loosens and falls out.

Install 1/2" (13 mm) certified gas pipe through opening.

After gas pipe installation is complete, use insulation that was removed from gas line tube to repack space around the pipe. Material should be inserted from outside of the fireplace and packed tightly to totally seal between the pipe and tube.

NOTE: Gas pipe should not come in contact with any wood structures until it has reached a point at least 1" (25 mm) away from fireplace side.

Note: Local codes may require removal of flue damper when installing any type of gas appliance in a fireplace.

NOTE: When installing an ANSI Z21.11.2 ventless appliance, the finishing material used for the mantel must be rated at 250°F or greater.

BTU input of a gas appliance installed in fireplace should be rated less than 100,000 BTU/Hr.

Gas pipe installation is intended for connection to a decorative gas appliance only when (1.) incorporating an automatic shutoff device and (2.) complying with the

Standard for Decorative Gas Appliances for Installation in Vented Fireplaces (ANSI Z21.60) or CSA draft requirements for Gas-Fired Log Lighters for Woodburning

Fireplaces (Draft No. 4, August 1993).

Decorative gas appliance should be installed in accordance with the National Fuel Gas Code, ANSI Z223.1/

NFPA 54 (latest edition).

Hole in

Outer

Casing

Gas Line

Tube

Hole in

Outer Casing

STR Series Woodburning Fireplaces

Fireplace Top View

1"

Supply Line

Repack Insulation

Ceramic

Knockout

(Both Sides on STR)

FP716

Fig. 29 Gas line access.

CAUTION: WHEN USING DECORATIVE

GAS APPLIANCE, FLUE DAMPER MUST

BE SET IN FULLY OPEN POSITION. IF YOU

HAVE GLASS DOORS ON THE FIREPLACE,

THEY MUST ALSO BE FULLY OPENED.

WARNING: DO NOT OPERATE AN

UNVENTED GAS LOG SET IN THIS FIRE-

PLACE WITH THE CHIMNEY REMOVED.

WARNING: WHEN INSTALLING AN

UNVENTED GAS LOG SET, THE MHSC

MODEL AH3244BK OR AH3244PB 4" AD-

JUSTABLE HOOD MUST BE USED.

If installing an unvented gas log set, refer to statement below:

Only unvented gas log sets which have been found to comply with the Standard for Unvented Room Heaters, ANSI Z21.11.2, are to be installed in this fireplace.

7412961 19

STR Series Woodburning Fireplaces

1, 2, 3

4 d

5 b

7 c

8 a

6

9

11

10

12

961

MHSC reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice.

STR33/36/42 SERIES

Ref. Description

1. Flue Damper

2. Damper Handle

961

STR parts

5/16/00 djt

3. Damper Handle Push Nut

4. Screen Rod Assembly (two per fireplace)

5. Screen Assembly (four per fireplace)

6. Screen Pulls (four per fireplace)

7a. Firebrick - Hearth

7b. Firebrick - Side Ashlip (two per fireplace)

7c. Firebrick - Side (two per fireplace)

7d. Side Filler (four per fireplace)

8. Top Brick Retainers (four per fireplace)

9. Cable Clips (eight per fireplace)

10. Nailing Flange (eight per fireplace)

11. Basket Grate

12. O.S.A. Assy.

STR33

RP102

7548170

7512903

3049122

7554338

5584139

3100103

3100102

3079147

3079148

3079130

7512135

5069164

2056100

20003212

STR36

RP102

7548170

7512903

3030126

7554338

5584139

3102103

3102102

9079147

3079148

3079130

7512135

5069164

2056100

20003212

STR42

RP161

7548169

7512903

3032112

7554340

5584139

3101105

3101103

3079147

3079148

3079130

7512135

5069164

2058100

20003212

20 7412961

STR Series Woodburning Fireplaces

Accessories

The following accessories for this appliance are available from your local Majestic Fireplaces distributor. Should you need additional information beyond what your distributor can furnish, contact: MHSC, 149 Cleveland Drive, Paris, KY

40361, Attn: Technical Services.

CAUTION: This fireplace and chimney assembly is a highly engineered system, and, as such, must be operated only with MHSC approved components. If you use an unapproved component to make any modifications, you may create a possible fire hazard and will void the MHSC warranty. In addition, such action may void the coverage provided by the owner’s insurance.

Accessory

Gl ass Door

Polished Brass finish 33GDKDP - STR33

36GDKDP - STR36

42GDKDP - STR42

Outside Air Termination Completes connection from air kit to out-of-doors

Pewter finish

Hearth Extension Insulation Provides hearth extension floor protection

Basket Grate

Hearth Patch Compound

Description

Bi-Fold door set Brushed Brass finish

Black finish

Holds firewood in firebox

Patch cracks in hearth

AK-MST

EH2416

RBG36ST (33" & 36" models)

RBG42ST (42" models)

HPC-1

Model Number

36GDKBB - STR36

42GDKBB - STR42

36GDKBK - STR36

42GDKBK - STR42

36GDKS - STR36

42GDKS - STR42

Contact your Majestic Fireplaces distributor or dealer for finishing

Marble and Mantels, available in a wide selection of styles.

7412961 21

STR Series Woodburning Fireplaces

Chimney Components

U.S.

Component Description Model Number

Round Top Termination Round termination to be used with SK8 chimney system. (Flashing not included.)

RLTSK8

Round Top Termination Round termination to be used with 11CF chimney RLTCF11 system. (Flashing not included.)

Long Round Top

Termination

Round top to be used with a chase installation utilizing SK8 chimneysystem.

RLTSK8L

RLTCF11L Long Round Top

Termination

Round top to be used with a chase installation utilizing 11CF chimney system.

Knock-down Shroud - Black pyramid knock-down shroud used for

Pyramid chase installations with any RLT round top termination. Gives appearance of a pyramid cap.

Knock-down Shroud - Black square knock-down shroud used for

Square chase installations with any RLT round top termination. Gives appearance of a square cap.

PKDSBL

Square Termination Top housing with simulated brick pattern.

(Red, Tan or Black) Proper adapter must be used. Includes flashing.

SKDSBL

Adaptor required

T20B

Adapter

Housing Extensions

Flashing

Required adapters for T20B top housing. CF8CA (SK8)

8CA (11CF)

Extends Square Termination on steep pitched roofs. 202036

Metal finishing required around Contemporary

Square Termination Top housing of simulated brick pattern

Termination to prevent rain leakage. available in red, tan or white. Appropriate adapter required. Flashing included.

8-6-12 with 8" flue:

0-6/12 pitch

8-12-12 with 8" flue:

6/12-12/12 pitch

T20B

SK8

Chimney Sections

Pipe used to build 8" SK8 flue systems.

11CF Chimney Sections Pipe used to build 11" (11CF) flue systems.

Chimney Elbows Elbow used to create an offset in a chimney system. Only 30˚ elbows available.

Packaged 2 per carton (offset and return).

SK81 (1' Long)

SK818 (1¹⁄₂' Long)

SK83 (3' Long)

SK84 (4' Long)

11CF1 (1' Long)

11CF18 (1¹⁄₂' Long)

11CF3 (3' Long)

11CF4 (4' Long)

SK830 / 2 (SK8)

11CF30 / 2 (11CF)

22 7412961

STR Series Woodburning Fireplaces

U.S. Chimney Components,

cont'd.

Component

Firestop

Chimney Support

Attic Insulation Shield

Description Model Number

Required at each floor level of chimney SKFS2A — SK8 installation. (Plus attic on multi-story installation.) (8" straight flue)

SKFS6A — SK8

(8" 30˚ inclined flue)

FS2A (Model 11CF)

(straight flue)

FS6A (Model 11CF)

(30˚ inclined flue)

Used to support chimney for each of: 20' vertical SKCS8 - SK8 height and 6' of angled chimney run. 11CS - 11CF

Used to prevent insulation from coming in contact AIS-SK - SK8 with the chimney system. FS2100-HT - 11CF

Canada

Component

Attic Insulation Shield

Attic Insulation Shield

SK8 Chimney Sections

45˚ Chimney Elbows

Description Model Number

Used to prevent insulation from coming in contact with the chimney system.

AIS-SK - SK8

Used to prevent insulation from coming in contact FS2100-HT with the chimney system. For use with CF11 pipe.

Used to build chimney systems exposed above roof.

SK818CAN (1¹⁄₂') SK8

SK84CAN (4') SK8

Provides 45˚ offset and return. FOR CANADIAN

INSTALLATIONS ONLY. For use with

SK8 chimney only. (Maximum use of 2, or 1pair.)

SK845/2

7412961 23

LIMITED WARRANTY

Factory-Build Fireplace and Components

(Except Blowers)

What is Covered and For How Long

Five-Year Coverage: For five years from the date this fireplace and components are first purchased for use, MHSC will, at its option, repair or replace any defective part of this fireplace or components, or refund to you a sum not to exceed the factory retail price in effect at the time of purchase.

Ten-Year Coverage: From the sixth through the tenth year following the date this fireplace or accessory is first purchased for use, MHSC will make available to you, at our factory, a free replacement for any defective part in this fireplace or accessory.

Twenty-Five-Year Availability of Replacement Parts: From the eleventh through the twenty-fifth year following the date this fireplace or accessory is first purchased for use, MHSC will make available at our factory replacement parts for this fireplace or accessory, which you may purchase for the list price current at the time your purchase order is received.

What is Not Covered

• This limited warranty does not cover:

• Transportation or shipping cost.

• The cost of a service call to diagnose trouble.

• Painted surfaces.

• Damage or defect caused by improper installation, accident, misuse, abuse or alteration.

• Poor ventilation of smoke or gases caused by air-conditioning and heating systems, exhaust fans, or pressure differentials produced by wind.

• Broken glass components.

• Cracks in ceramic and castable parts that do not affect safe operation.

• We do not warrant this fireplace to be in compliance with your local building code. Building codes vary greatly throughout the country, and you should determine whether your local building code contains restrictions on the use of this fireplace before you purchase it.

• Blowers or fans, which are warranted separately.

• Heat loss due to the passage of heat or air through or around the fireplace.

Also, under our five year coverage, we do not pay the cost of removal and replacement of any portion of the structure in which the fireplace is situated, made necessary by the repair, removal or re-installation of the fireplace.

And under our twenty-five year warranty of availability of replacement parts, we only promise to maintain a supply of replacement parts at our factory for you to purchase.

Limitations and Exclusions

1. No one has authority to add to or vary this limited warranty, or to create for MHSC any other obligations of liability in connection with this fireplace and accessory.

2. MHSC shall not be liable for incidental, consequential, special or contingent damages you might suffer as a result of its breach of this written warranty or any implied warranty. Some states do not allow the exclusion of limitation of incidental or consequential damages, so the above limitations may not apply to you.

3. This warranty applies only to a fireplace sold and used in the United States.

IF WARRANTY SERVICE IS NEEDED...

1. Contact your supplier. Make sure you have your warranty, your sales receipt and the model/serial number of your

MHSC product.

2. DO NOT ATTEMPT TO DO ANY SERVICE WORK YOURSELF.