- No category
advertisement
LC1x70-E-DA
1x70 W Dimmable DALI LED driver
• Adjustable constant current output: 700 mA (default) - 1400 mA
• DALI control input 1 % - 100 % dimming range
• Low standby power <0.5 W
• Protected up to 4 kV power network fast transients
• Overload, open & short circuit protection
• Suitable for Class I, II or SELV luminaire
• External NTC thermal input
• Auxialiary 12 V ouput for active cooling (not for independent use)
• Current setting resistor input
• Optional strain relief for independent use (LC1x70-SR)
70 W 220-240 VAC 50-60 Hz
Connections
L
N
DA
L
N
Switch-Control
R
AUX, 12 V, ≤ 150 mA
NTC
I fv
= 700 -1400 mA
• Not suitable for load side switching operation.
• Switch-Control is only allowed to use in Class I luminaires and Class II luminaires with plastic casing
Mains Characteristics
Voltage range
DC range
198 - 264 VAC
176 - 280 VDC, starting voltage > 190 VDC
Max mains current at full load 0.33-0.40 A
Frequency
U-OUT max
(abnormal)
Stand-by power
0 / 50 - 60 Hz
120 V
< 0.5 W
Load Output
Output current (I-OUT)
Max output power
Auxiliary output
700 mA (default) - 1400 mA
70 W
12 V, ≤ 150 mA*
* Not alloved to be used in independent use
Efficiency, at full load, typical ≥ 0.91
I-OUT 700 mA
P-out (max) 70 W
U-OUT 30 - 100 V
λ 0.98
η @ max 0.91
1400 mA
70 W
30 - 50 V
0.98
0.88
Operating Conditions and Characteristics
Max.temperature at tc point 70 °C
Ambient temperature range -20…+50 °C *
(* Independent use t a max
= +40 °C)
Storage temperature range -40…+80 °C
Maximum relative humidity no condensation
Life time 50 000h, at TC max
(90 % survival rate)
Conformity & Standards
** with additional extensions
Current setting (p.2)
Resistor R output I fv
10 MΩ 700 mA
3.9 kΩ
0 Ω
1050 mA
1400 mA
Connections and Mechanical Data
Wire size
Wire type
0.5 - 1.5 mm 2 solid core and fine-stranded
Maximum driver to LED wire length 5m (1 m with NTC)
Weight
Thermal sensor input
(+25 g, strain relief LC1x70-SR)
Input for external
NTC
NTC trigger point thermal
8.2 kΩ
General and safety requirements EN 61347-1
Particular safety requirements for d.c. or a.c. supplied electronic controlgear for LED modules, acc. to EN 61347-2-13
Thermal protection class
Mains current harmonics, acc. to
EN 61347, C5e
EN 61000-3-2
Limits for Voltage Fluctuations and Flicker, acc to EN 61000-3-3
Radio Frequency Interference, acc. to EN 55015
Immunity standard, acc. to
Performance requirements, acc to
Digital adressing lighting interface (DALI) **
EN 61547
EN 62384
EN 62386-207
Compliant with relevant EU directives, ENEC, CE & SELV marked
Helvar | Data is subject to change without notice. More information at: www.helvar.com T22 031 1B 16.04.2014.2014 1/2 1
Dimensions
30
With strain relief (LC1x70-SR)
30
171
The LC1x70-E-DA LED driver is suited for either in-built and independent luminaire usage. In order to have safe and reliable LED driver operation, the LED luminaires will need to comply with the relevant standards and regulations (e.g. IEC/EN 60598-1). The LED luminaire shall be designed to adequately protect the LED driver from dust, moisture and pollution. The luminaire manufacturer is responsible for the correct choice and installation of the LED drivers according to the application and product datasheets. Specifications of the LED drivers may never exceed the operating conditions as per the product datasheets.
Wiring considerations Installation & operational considerations
Wire type and cross section
• Please refer to datasheets connections & mechanical data
Wiring insulation
• According to recommendations in EN 60598
Maximum wire lengths
• Please refer to datasheets connections & mechanical data
Wire connections
• Please refer to datasheets connections diagram
Miniature Circuit Breakers (MCB)
• Type-C MCB’s with trip characteristics in according to EN 60898 are recommended.
LED driver earthing
• LED drivers are designed to support different luminaire classifications, like Class I or Class II fittings (no earth required).
Please check the individual LED driver type for its exact safety class rating.
• For Helvar LED drivers to have a reliable operation and EMC performance, the luminaires are expected to have an earth connection.
• When using a SELV-rated LED driver, then the SELV driver output has to be insulated from the luminaire earth connection (ref.
EN60598-1 luminaire standard).
Maximum tc temperature
• Reliable operation and lifetime is only guaranteed if the maximum tc point temperature is not exceeded under the conditions of use.
Strain Relief for independent use
• The LC1x70-E-DA LED driver allow use both inside the luminaire and outside the luminaire, via the LC1x70-SR strain relief. The strain relief provides reliable fastening method for the mains and
LED output wiring.
• Ensure that the LED driver does not exceed temperature higher than specified on the product datasheets.
• The general preferred installation position of LED drivers is to have the top cover facing upwards.
Current setting resistor
The Helvar LC1x70 driver platform features an adjustable constant current output.
• An external resistor can be inserted in to the current setting terminal, allowing the user to adjust the LED driver output current.
• When no external resistor is connected, then the LED drivers will operate at their default lowest current level.
• A standard through-hole resistor can be used for the current setting. To achieve the most accurate output current it is recommended to select a quality low tolerance resistor.
• For the resistor / current value selection, please refer to the enclosed table below.
Auxiliary output for cooling fan
LC1x70-E-DA driver features an auxiliary output for cooling fan
• Auxiliary output is not allowed to be used in inpendent installation
• In-built luminaire use: Check auxiliary maximum loading (cooling fan) by actual luminaire temperature measurements.
Current setting resistor values (Nominal I
out
(±5 % tol.)
R (Ω) 0 1k 1.2K 1.5K 1.8K 2.2K 2.7K 3.3K 3.9K 4.7K 5.6K 6.8K 8.2K 10K 12K 15K 22K 27K 33K 39K 47K 56K 100K 150K 330K 1M
I out
(mA)
1400 1260 1230 1190 1160 1130 1100 1070 1050 1020 980 950 920 890 860 830 800 790 780 770 750 740 720 715 710 700
2 Helvar | Data is subject to change without notice. More information at: www.helvar.com T22 031 1B 16.04.2014 2/2