Amana Self Clean Gas Oven ARG7102

Amana Technical InformationGas Range
ARG7102
ARG7302
P1143338N, P1143341N, P1143344N, P1143347N, P1143370N
P1143389N, P1143399N
P1143337N, P1143343N, P1143368N, P1143391N
• Due to possibility of personal injury or property damage, always contact an authorized technician for servicing or
repair of this unit.
• This technical sheet replaces RT2310005 Rev. 5.
• Refer to Service Manual RS2310002 for detailed installation, operating, testing, troubleshooting, and disassembly
instructions.
• Refer to Parts Manuals RP2320042 and RP2310044 for part number information.
!
CAUTION
All safety information must be followed as provided in Service Manual RS2310002.
!
WARNING
To avoid risk of electrical shock, personal injury, or death, disconnect power to oven before servicing, unless
testing requires it.
Models
Power Source
Electrical rating
Amperage
Frequency
Water Column Pressure
Natural
LP/Propane
Surface Burner (BTU Nat./LP)
Two burners
Four burners
Two burners
Oven Burner (BTU Nat./LP)
Bake
Insta-Broil
Oven Interior Dimensions in. (cm)
Height
Width
Depth
Product Exterior Dimensions in. (cm)
Height overall
Width
Depth oven door closed with handle
Clearance oven door
Height of cooktop
Weight lbs. (kg)
Approximately shipping weight
Features
High performance sealed burners
Square wire/cast iron burner grates
Frameless glass door with window
Interior oven light
Two oven racks5 positions
Exclusive Insta-Broil system
Removable full width storage drawer
Self-cleaning porcelain oven
Eaton electronic range controlKRC
January 2001
ARG7102
ARG7302
120 VAC
15 Amp
60 Hz
120 VAC
15 Amp
60 Hz
6 in. W.C.P.
10 in. W.C.P.
6 in. W.C.P.
10 in. W.C.P.
9,700/8,000
9,700/8,000
12,500/10,000
15,500/15,500
14,000/13,000
15,500/15,500
14,000/13,000
16 (41)
23 (58)
17 1/2 (44)
16 (41)
23 (58)
17 1/2 (44)
47 (119)
30 (76)
28 1/4 (72)
20 (51)
36 (91)
47 (119)
30 (76)
28 1/4 (72)
20 (51)
36 (91)
171 (78)
171 (78)
X
Wire grates
X
X
X
X
X
X
X
1
X
Cast iron
X
X
X
X
X
X
X
RT2310005 Rev. 6
Component Testing Procedures
!
WARNING
To avoid risk of electrical shock, personal injury, or death, disconnect power to oven before servicing, unless
testing requires it.
Illustration
31823701
Component
Oven light socket
Test Procedure
Test continuity of receptacle terminals.
Results
Indicates continuity with bulb screwed in.
Measure voltage at oven light.
120 VAC, see wiring diagram for terminal
identification.
If no voltage is present at oven light,
check wiring.
0063997
Rocker switch
Measure voltage at rocker switch to
chassis.
120 VAC, see wiring diagram for terminal
identification.
0314367
Door plunger switch
Remove switch from unit and measure
the following point:
C-NC
Plunger in infinite, Plunger out continuity.
(if so equipped)
NC
C
0304579
Hi temperature
latch switch
NC
NO
COM
31864501
Eaton electronic
range control−KRC
Test for voltage at terminals to chassis
when in bake, broil, or clean mode.
COM to chassis
Only when latch is engaged:
NO to chassis
Measure voltage at terminals:
P3 (L1) and P4 (NEU)
120 VAC
120 VAC
120 VAC should be indicated.
P1
1 12
P6
P5
P4
P3
Relays
Remove leads and measure for
continuity.
1
P2
Drive requirements
Bake
Broil
Clean
Stage 1
Stage 2
Time
0314907
Sensor, Oven
Temperature
31715201−LH
0317068−RH
Hinge
Opening
0308866
Pressure regulator
F2-Oven over temperature
F3-Open oven temperature sensor
F4-Shorted oven temperature sensor
FFF-Control failure
Measure resistance.
Carefully open the hinge fully, and
insert a wooden dowel or screwdriver
bit into opening.
Remove top and bottom screws
securing hinge.
Slide hinge top towards rear of unit
and guide hinge out through frame
opening or storage drawer.
Verify gas pressure (WCP).
If on LP service verify proper gas
supply conversion.
See schematic.
100% bake element
100% broil element
Time controlled 30 minutes 100% broil
100% bake
4 hours with last 30 minutes for cool
Verify voltage to clock.
If no voltage is present, check wiring.
If voltage is present, replace clock.
Approximately 1100 Ω at room
temperature 75°F.
!
CAUTION
Do not place hands in hinge area when
oven door is removed. Hinge can snap
closed and pinch hands or fingers.
6" Natural
10" LP/propane
! WARNING
To avoid risk of fire, always test for leaks
after a gas component repair.
RT2310005 Rev. 6
2
January 2001
Component Testing Procedures
!
WARNING
To avoid risk of electrical shock, personal injury, or death, disconnect power to oven before servicing, unless
testing requires it.
Illustration
31940001−Bake
31939901−Broil
0309159
Component
Norton ignitor
0316220
Gas valve
Test Procedure
Test for voltage at terminals.
Test for the amount of amperage in the
circuit.
(Ignitor may glow but not have
sufficient amperage to open valve).
Disconnect wiring to valve.
Measure resistance on bake circuit.
Measure resistance on broil circuit.
Results
120 VAC
3.2− 3.6 Amps.
Continuity
Continuity
! WARNING
Do not attempt to open valve with
120 VAC.
0306428
Shut off valve
Check to verify gas supply is turned
on.
90° valve
Verify gas is supplied.
H
R
G
AA
31742501−9K
31727701−12K
Orifice adjusted for Natural or LP.
0316538
Spark 90° switch
0316773
Spark ignition
electrode
Top surface burner
0315768−9K
0315767−12K
Test for voltage at terminals.
120 VAC
Disconnect wiring and check for
continuity in LITE position.
Test for resistance of spark lead.
Continuity in LITE position.
Test ignitor to chassis.
No continuity from ignitor to chassis.
Continuity
Verify gas is supplied.
Verify burner cap is positioned
correctly.
0316211
0060691
Bake burner
Check for obstructions in burner ports.
Verify gas is supplied.
Broil burner
Orifice adjusted for Natural or LP.
Check for obstructions or
contamination in ports.
Verify gas is supplied.
Venturi
0315154
L
N
Spark module 4 + 0
A
Proper orifice installed for Natural or
LP.
Check for damage to screen.
Shutter settings:
Nominal
Tol. ±
Test for voltage at terminals L and N.
B
A1
January 2001
Replace if punctured or torn.
.125" 1/8"
.031" 1/32"
120 VAC
See wiring diagram.
B1
3
RT2310005 Rev. 6
Component Specifications
!
WARNING
To avoid risk of electrical shock, personal injury, or death, disconnect power to oven before servicing, unless
testing requires it.
• After burner control panel clears valve stems,
continue to roll panel until free from range. Set
aside.
• Gas valve and orifice hood are visible after burner
control panel is removed.
Converting from Natural Gas to LP Gas

Converting the Insta-Broil
1. Remove or open oven door.
2. Remove screws securing Insta-Broil bracket.
3. Remove burner carefully, avoid damaging the ignitor
to expose burner spud. Remove the #52 natural gas
burner spud using a 5/16 socket wrench. Save #52
spud to reconvert if necessary in the future.
4. Install the #58 LP/propane spud (wired to inlet pipe).
5. Replace Insta-Broil burner and holding screws.
A
B
Converting Oven Burner for Use with LP/Propane
1. Remove storage drawer.
2. Locate and remove 2 screws attaching Z-shaped
cover plate.
• Cover plate located in center, rear of storage
drawer cavity.
• Removing cover plate exposes oven burner orifice
and air shutter.
D
E
C
A—Burner Control Knob
B—Pivot Point
C—Burner Control Panel
4. While facing range front, turn orifice hoods
counterclockwise 1½ to 2 turns or until snug.
• Use ½ inch open end or 90° offset open end
wrench.
• Do not over tighten orifice hoods. If orifice hoods
are over tightened, gas supply can be cut off or
orifice hoods can damage LP pin.
5. Reassemble burner control panel after adjusting air
shutter.
Converting Pressure Regulator for LP/Propane
1. Remove pressure regulator cap using a 7/8 inch
wrench.
2. Reverse pressure regulator cap.
• Cap must show “LP”.
3. Place pressure regulator cap on pressure regulator
and tighten.
A
C
B
A—Air Shutter Screw
B—Orifice Hood
C—Air Shutter
3. Turn orifice hood clockwise until snug.
• Do not over tighten orifice hoods. Orifice hoods can
damage LP pin.
4. Replace cover plate and storage drawer.
Converting Surface Burners for Use with LP/Propane
1. Remove 4 burner control knobs from range.
• Expose 2 screws on burner control panel.
2. Remove 2 screws from burner control panel.
• Panel drops slightly after screws are removed.
3. Grasp bottom of burner control panel, gently lift and
pull out panel until clear of burner valve stems.
RT2310005 Rev. 6
D—Screw
E—Orifice Hood
Adjusting Burner Flame
Properly adjusted burner flames are clean and blue with
a distinct inner cone approximately ½ inch long.
• If burner flame is blowing or noisy, reduce airflow to
burner.
• If burner flame is yellow and does not hold its shape,
increase airflow to burner.
4
January 2001
Wiring Diagram and Schematic
!
WARNING
To avoid risk of electrical shock, personal injury, or death, disconnect power to oven before servicing, unless
testing requires it.
January 2001
5
RT2310005 Rev. 6
Component Specifications
!
WARNING
To avoid risk of electrical shock, personal injury, or death, disconnect power to oven before servicing, unless
testing requires it.
RT2310005 Rev. 6
6
January 2001