369AAN
Multipoise Oil Furnace
Input Capacities; 70,000 thru 154,000 Btuh
Series D
Product Data
369AAN FEATURES/BENEFITS
Beckett Oil Burner and UTEC Controls
S High quality Beckett oil burner allows safe and
efficient combustion of oil.
S
UTEC ignition control and fan timer board provide
reliable operation and easy connection of thermostat
and accessory wiring.
Casing
S Made of 20--gauge, powder--painted steel for years of
durability and attractiveness.
S
Cabinet features a reversible door, ensuring ease of
service access even in downflow applications.
Insulation and Soundproofing
S Unique silencer baffle, insulated walls and rubber
blower mounts capture most combustion noise and
vibration and make this unit one of the quietest on the
market.
Combustion Products Venting
S Top or side flue outlet.
S Unit may be vented using Type L vent material and a
factory--built metal or masonry chimney.
S
A06623
Unit may also be sidewall vented with an approved
power venter.
Adjustable Blower Speed
S 4--speed blower for precise airflow selection of heating
THE LATEST IN OIL FURNACE
TECHNOLOGY
or cooling operation.
Constant Low--Speed Blower Switch
S Allows continual low--speed air circulation through the
The model 369AAN combines high efficiency and quiet
operation with oil heating technology. The 369AAN is available
in 2 sizes. Each size can be fired at 3 different rates by a simple
nozzle and pump pressure change. Unit 369AAN105 covers
input ranges from 70,000 to 105,000 Btuh. Unit 369AAN120
covers input ranges from 119,000 to 154,000 Btuh. The furnace
design is a multipoise style for upflow, downflow, and horizontal
applications.
The components of the 369AAN are the finest in the industry.
The unit uses a Beckett oil burner with a “clean--cut” oil pump,
UTEC ignition controller, and fan cycle timer.
The 369AAN is a standard part of a quality--built home. This
energy efficient furnace will provide years of quality service to
home builders and homeowners alike.
As with other Bryant furnaces, this model is designed to work as
part of a total home comfort system which includes elements for
cooling, air cleaning, humidification, ventilation, and zoning.
This unit is not approved for use in mobile home installations.
home to
efficiency.
maximize
comfort
while
maintaining
S Air is constantly filtered and stagnant air is avoided.
S This option can be controlled by the homeowner.
Combustion Chamber/Heat Exchanger
S Composed mainly of stainless and aluminized steel, the
unique combination
combustion
chamber/heat
exchanger resists corrosion, overheating, and
deterioration.
S Heat transfer properties make it energy efficient.
S All seams are tightly welded for leak--free operation.
Certifications
S 369AAN unit is CSA certified.
S The efficiency is AHRI efficiency rating certified.
1
UNUSED
3
1
2
3
4
5
X
H
U
M
LEADS
N
S
2
E
A
C
C
O
N
T
C
O
O
L
H
E
A
T
6
7
C
1 2
ON
G
W
R
Y
C
A03172
A97246
369AAN
A96370
COMBUSTION CHAMBER/
HEAT EXCHANGER
CONTROL CENTER
OIL BURNER
Always Ask For
C
US
Use of the AHRI Certified TM Mark indicates a
manufacturer’s participation in the program. For
verification of certification for individual products,
go to www.ahridirectory.org.
2
6
7
8
5
4
3
369AAN
9
2
10
11
1
12
SEE NOTES: 13, 14
Left side, right side, or bottom.
A97244
1. Heavy--duty blower circulates air across the heat exchanger to transfer heat into the home.
2. Stainless steel combustion chamber/primary heat exchanger.
3. Unique silencer system reduces combustion noise.
4. Heat exchanger designed and shaped to efficiently transfer heat from furnace into the home.
5. Fully insulated internal walls to minimize heat loss and reduce sound.
6. Supply--air plenum.
7. High limit control to prevent overtemperature operation.
8. Reversible door provides easy access to burner and controls.
9. High--performance oil burner.
10. Manual switch to allow user control of constant low--speed blower operation.
11. Adjustable electronic fan timer control (inside) has low voltage electrical terminal strip for easy connection of thermostat, cooling
control, electronic air cleaner, and humidifier.
12. Access door to blower.
13. Air filter (field supplied).
14. Return--air plenum.
3
CLEARANCE TO COMBUSTIBLES
UNIT APPLICATION
SIDES
UPFLOW
DOWNFLOW
HORIZONTAL
Furnace
0
2
2
Supply Plenum and Warm--- Air Duct Within 6 Ft
of Furnace
1
2
1
BACK
TOP
Furnace
0
1
0
Furnace Casing or Plenum
2
2
2
Horizontal Warm--- Air Duct Within 6 Ft of
Furnace
2
2
3
BOTTOM
FLUE PIPE
Furnace
0
0*
0*
Horizontally or Below Pipe
4
4
4
Vertically Above Pipe
9
9
9
8
8
24
FRONT
369AAN
*For combustible floor, use approved accessory subbase.
NOTE: Adequate service clearance should be provided over and above these dimensions as required.
PHYSICAL DATA
UNIT SIZE
036105
060120
INPUT (BTUH)
70,000
91,000
105,000
119,000
140,000
HEATING CAPACITY (BTUH)*
57,000
74,000
85,000
97,000
115,000
126,000
0.50 --- 70W
0.55 --- 70B
0.65 --- 70B
0.75 --- 70B
0.85 --- 70B
0.85 --- 70B
0.50
0.65
0.75
0.85
1.00
1.10
80.5
80.5
80.5
80.5
80.5
80.5
DOWNFLOW
80
80
80
80
80
80
HORIZONTAL
80
80
80
80
80
80
OIL PUMP STAGES/PRESSURE
(PSIG)
1/100
1/140
1/130
1/130
1/140
1/170
HEATING TEMP RISE _F
NOZZLE
FIRING RATE (GPH)
AFUE%
UPFLOW
154,000
55--- 85
55--- 85
55--- 85
55--- 85
55--- 85
55--- 85
COOLING CFM @ 0.5---IN. WC
STATIC PRESSURE
1250
1250
1250
1865
1865
1865
HEATING CFM @ 0.2---IN. WC
STATIC PRESSURE
840
1130
1425
1220
1535
1890
Med --- Low
Med --- High
High
Med --- Low
Med --- High
High
RECOMMENDED HEATING
BLOWER SPEED
SHIPPING WEIGHT (LB)
BURNER MODEL (3450 RPM){
235
235
235
260
260
260
BECKETT
AFG--- F3
BECKETT
AFG--- F3
BECKETT
AFG--- F3
BECKETT
AFG--- F3
BECKETT
AFG--- F3
BECKETT
AFG--- F6
* Capacity and AFUE in accordance with U.S. Government DOE test procedures.
{ Beckett AFG---F6 requires field---supplied and replacement burner firing head.
Shaded cells are as factory shipped.
4
PERFORMANCE DATA
036105
060120
DIRECT ---DRIVE MOTOR Hp (PSC)
UNIT SIZE
1/3
3/4
MOTOR FULL LOAD AMPS
6.2
9.5
RPM (Nominal) --- SPEEDS
1075--- 4
1075--- 4
BLOWER WHEEL DIAMETER X WIDTH (In.)
FILTER SIZE (In.) --- (Disposable, Field Supplied)
10 x 10
12 x 10
16 x 24 or 25 x 1
20 x 30 x 1
AIR DELIVERY --CFM (WITH FILTER)
036105
060120
BLOWER
MOTOR HP
1/3 PSC
3/4 PSC
SPEED
EXTERNAL STATIC PRESSURE (In. wc)
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
High
1425
1350
1305
1250
1170
1030
925
805
Med --- High
1130
1045
1000
950
885
820
745
670
Med --- Low
840
810
770
740
685
635
580
500
Low
725
730
740
745
730
715
690
665
High
2080
2040
1965
1865
1700
1575
1475
1335
Med --- High
1890
1860
1770
1675
1550
1450
1330
1215
Med --- Low
1555
1475
1395
1320
1210
1135
1050
940
Low
1220
1165
1080
1000
925
855
780
655
ELECTRICAL DATA
UNIT SIZE
036105
060120
115 --- 60 --- 1
115 --- 60 --- 1
104 --- 132
104 --- 132
12.2
15.7
MINIMUM WIRE SIZE (AWG)
14
12
MAXIMUM WIRE LENGTH (Ft){
26
26
MAXIMUM FUSE SIZE OR CKT BKR (Amps)}
15
20
40va
40va
Heating
40va
40va
Cooling
30va
30va
Standard
Standard
UNIT VOLTS---HERTZ --- PHASE
OPERATING VOLTAGE RANGE (Min---Max)*
MAXIMUM UNIT AMPS
TRANSFORMER (24v)
EXTERNAL CONTROL POWER AVAILABLE
AIR CONDITIONING RELAY
* Permissible limits of the voltage range at which the unit will operate satisfactorily.
{ Length is a measured one way along wire path between unit and service panel for maximum 2% voltage drop.
} Time ---delay fuse type is recommended.
5
369AAN
UNIT SIZE
DIMENSIONS
A
TOP KNOCK-OUT
FOR J DIAM VENT
20″
19″
E
3″
G
KNOCK-OUT BOTH SIDES
FOR J DIAM VENT
19″
369AAN
PULL
VENT CONN
B
C
OIL INLET
(BOTH SIDES)
2″
H
L
F
D
ELECTRICAL
CONNECTIONS
(BOTH SIDES)
.88 DIAM TYP
20″
K
A98037
DIMENSIONS (IN.)
UNIT SIZE
A
B
C
D
E
F
G
H
J
K
L
036105
35
48--- 3/4
31--- 1/4
16--- 5/8
20
22
12
14
5
1--- 1/2
1--- 3/4
060120
39--- 1/2
53
33--- 1/4
18--- 3/4
24
28
12--- 19/32
16
6
1--- 5/8
1--- 1/2
6
Available in programmable and
non ---programmable models,
Bryant thermostats maintain a
constant, comfortable temperature level in the home.
For the ultimate in home comfort, Bryant’s 2, 4, and 8 ---zone
systems allow temperature control of individual “zones” of the
home. This is accomplished
through a series of electronic
dampers and remote room sensors. The 4 ---zone system is
shown.
A94336
ENERGY/HEAT
RECOVERY
VENTILATOR
Bryant’s energy or heat recovery ventilators exhaust
stale indoor air and provide
fresh outdoor air to the home
while minimizing heat loss
and humidity level. Especially useful for today’s tighter
constructed houses.
Energy recovery ventilator is
shown.
A07043
ELECTRONIC OR
MECHANICAL AIR
CLEANER
Cleans the air of smoke, dirt,
and many pollens commonly
found. Saves decorating and
cleaning expenses by keeping
carpets, furniture, and drapes
cleaner.
Electronic air cleaner is
shown.
A91365
HUMIDIFIER
By adding moisture to winter --dry air, Bryant humidifier can
often improve comfort and
keeps woodwork, wallpaper,
and paint in better condition.
Moisturizing household air
also helps to retain normal
body heat and provides comfort at lower temperatures.
ACCESSORIES
KLASB0601DET
KLASB0701DET
KLABV0101DET
KLADC0101DET
KLADC0201DET
FURNACE ACCESSORIES
Downflow Subbase Kit --- Required for combustible floors
Horizontal Subbase Kit --- Required for combustible floors
Blocked Vent Shutoff Kit
Downflow Conversion/Vent Guard --- Required for downflow operation, Model 036105
Downflow Conversion/Vent Guard --- Required for downflow operation, Model 060120
ZONEBB2KIT01--- B
ZONEBB4KIT01--- B
ZONEBB8KIT01--- B
PROGRAMMABLE THERMOSTAT SELECTION
Thermostat, Manual Changeover, 5--- 2 Day Programmable, °F/°C, 1--- Stage Heat/1--- Stage Cool
Thermostat, Manual Changeover, 5--- 2 Day Programmable, °F/°C, 2--- Stage Heat/1--- Stage Cool
Thermostat, Auto Changeover, 5--- 2 Day Programmable, °F/°C, 1--- Stage Heat/1--- Stage Cool
Thermostat, Auto Changeover, 5--- 2 Day Programmable, °F/°C, 3--- Stage Heat/2--- Stage Cool
NON--- PROGRAMMABLE THERMOSTAT SELECTION
Thermostat, Manual Changeover, Non--- Programmable, °F/°C, 1--- Stage Heat/1--- Stage Cool
Thermostat, Manual Changeover, Non--- Programmable, °F/°C, 2--- Stage Heat/1--- Stage Cool
Thermostat, Auto Changeover, Non--- Programmable, °F/°C, 1--- Stage Heat/1--- Stage Cool
Thermostat, Auto Changeover, Non--- Programmable, °F/°C, 3--- Stage Heat/2--- Stage Cool
ZONING CONTROL SELECTION
Comfort Zone II--- B --- 2 Zone Kit/Temperature and Humidity Control
Comfort Zone II--- B --- 4 Zone Kit/Temperature and Humidity Control
Comfort Zone II--- B --- 8 Zone Kit/Temperature and Humidity Control
HUMBBSBP2312
HUMBASBP2312
HUMBBLBP2317
HUMBALBP2317
HUMBBLFP1318
HUMBALFP1318
HRVBBSHA1100
HRVBBSVA1100
HRVBBLHA1150
HRVBBLHA1250
HRVBBSVU1150
HRVBBSVU1200
HRVBBLVU1150
HEALTHY HOME SOLUTIONS
Humidifier --- 12 g./day, 24V Standard, Small Bypass
Humidifier --- 12 g./day, 24V Automatic, Small Bypass
Humidifier --- 17 g./day, 24V Standard, Large Bypass
Humidifier --- 17 g./day, 24V Automatic, Large Bypass
Humidifier --- 18 g./day, 24V Standard, Fan Powered
Humidifier --- 18 g./day, 24V Automatic, Fan Powered
Heat Recovery Ventilator --- Small Horizontal Unit, 100 CFM
Heat Recovery Ventilator --- Small Vertical Unit, 100 CFM
Heat Recovery Ventilator --- Large Horizontal Unit, 150 CFM
Heat Recovery Ventilator --- Large Horizontal Unit, 250 CFM
Heat Recovery Ventilator --- Small Vertical Unit, 150 CFM
Heat Recovery Ventilator --- Small Vertical Unit, 200 CFM
Heat Recovery Ventilator --- Large Vertical Unit, 150 CFM
T1--- PAC01
T1--- PHP01
T2--- PAC01
T2--- PHP01
T1--- NAC01
T1--- NHP01
T2--- NAC01
T2--- NHP01
7
369AAN
A07042
CONTROLS:
THERMOSTATS
AND ZONING
ACCESSORIES (CONT)
HRVBBLVU1200
HRVBBLVU1330
ERVBBLHU1150
ERVBBLHU1200
EZXCABBB1016
EZXCABBB1020
Heat Recovery Ventilator --- Large Vertical Unit, 200 CFM
Heat Recovery Ventilator --- Large Vertical Unit, 330 CFM
Energy Recovery Ventilator --- Large Horizontal Unit, 150 CFM
Energy Recovery Ventilator --- Large Horizontal Unit, 200 CFM
Media Filter Cabinet --- 1600 CFM (Replacement Filter: EXPXXFIL0016)
Media Filter Cabinet --- 2000 CFM (Replacement Filter: EXPXXFIL0020)
369AAN
TYPICAL INSTALLATION
AIR CONDITIONER
OR HEAT PUMP
RETURNAIR DUCT
SUPPLY-AIR DUCT
A/C COIL
CHIMNEY
VENT
PIPE
OIL TANK
BAROMETRIC
DRAFT
DAMPER
OIL FURNACE
AIR FLOW
A98026
EBryant Heating & Cooling Systems 7310 W. Morris St. Indianapolis, IN 46231
Printed in U.S.A.
Edition Date: 10/10
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
8
Catalog No. PDS369A.70.3
Replaces: PDS369A.70.2