Modbus Master/Slave to IEC 60870-5-101

Slave Gateway

5102-MCM3-101S

The MCM-101S modules are the ideal solution for the many applications where Modbus connectivity can be used to integrate an IEC 101 master device into a system. The IEC60870-5-101 Slave gateway is a powerful module designed with Slave support, enabling easy connection to an IEC 101 master device. In combination with the Modbus device support, the module provides a very powerful interface to the many

Modbus devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil

and Gas, Electrical Power and Food Processing.

How to Contact Us: Sales and Support

All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide

Technical Support team directly by phone or email:

Asia Pacific

+603.7724.2080, [email protected]

Languages spoken include: Chinese, Japanese, English

Europe – Middle East – Africa

+33 (0) 5.34.36.87.20, [email protected]

Languages spoken include: French, English

North America

+1.661.716.5100, [email protected]

Languages spoken include: English, Spanish

Latin America (Sales only)

+1.281.298.9109, [email protected]

Languages spoken include: Spanish, English

Brasil

+55-11.5084.5178, [email protected]

Languages spoken include: Portuguese, English

Modbus Master/Slave to

IEC 60870-5-101 Slave Gateway

5102-MCM3-101S

The ProLinx Modbus Master/Slave to IEC60870-5-101 Slave

Gateway creates a powerful connection between devices on a

Modbus network and an IEC 101 master device. This stand-alone

DIN-rail mounted protocol gateway provides one IEC 101 Slave configurable serial port and three Modbus Master or Slave configurable serial ports.

The Modbus protocol driver supports Master and Slave implementations of the protocol. All Modbus serial ports are individually configurable, providing a very powerful and flexible host or device interface solution.

The IEC 60870-5-101 Slave protocol driver supports Slave implementations of the protocol. The serial port is user-configurable, providing a very powerful and flexible host or device interface solution.

Modbus Master/Slave

The Modbus driver provides extensive support for both the Master and the Slave implementations of the protocol. The serial port(s) on the gateway can be individually configured to support the Modbus protocol (Master or Slave, RTU or ASCII, Baud rate, etc.).

General Parameters – Modbus Protocol

Communication parameters

Baud Rate: 110 to 115K baud

Stop Bits: 1 or 2

Data Size: 7 or 8 bits

Parity: None, Even, Odd

RTS Timing delays: 0 to 65535 ms

Error Checking

Floating Point

Function Codes

RTU mode (binary) with CRC-16

ASCII mode with LRC error checking

Floating point data movement supported, including configurable support for Enron implementation

1: Read Output Status

2: Read Input Status

3: Read Multiple Data Registers

4: Read Input Registers

5: Write Single Bit

6: Write Single Data Register

15: Write Multiple Bits

16: Write Multiple Data Register

Modbus Master

Command List

Polling of command list

Up to 100 command per master port, each fully configurable for function, slave address, register to/from addressing and word/bit count.

Configurable polling of command list, including continuous and on change of data, and dynamically user or automatic enabled.

Modbus Slave

Node address 1 to 247 – software selectable

IEC 60870-5-101 Slave

The 101S module acts as an input/output module between the

IEC 60870-5-101 and other protocols and networks, as well as several proprietary interfaces.

General specifications include:

• User-definable module memory usage

• Storage of IEC time used in module is available in the database

• Protocol implementation conforms to the IEC 60870-5-101 specification with fully configurable parameters

• Priority Queues

• Invalid Bit Monitoring

• Supports Balanced and Unbalanced Mode

• Supports CP24 and CP56 time formats for events

• Event generation configurable per point or data type

General Parameters

Communication parameters

Baud Rate: 110 to 19,200 baud

Stop Bits: 1 or 2

Data Size: 5 or 8 bits

Parity: None, Even, Odd

RTS Timing Delays: 0 to 65535 ms

IEC 60870-5-101 Slave

Configurable Parameters Data link address length

Common Address of ASDU length

Inform. Object Address length

Select/Operate Timeout

Event Scan delay

Use Balanced Mode

Short Pulse Time

Long Pulse Time

Time DB Offset

General Specifications

The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.

Hardware Specifications

Specification Description

Power Supply 24 VDC nominal

18 to 36 VDC allowed

Positive, Negative, GND Terminals

2.5 mm screwdriver blade

Current Load 500 mA max@ 24 VDC

Operating Temperature –20 to 50°C (–4 to 122°F)

Storage Temperature

Relative Humidity

–40 to 85°C (–40 to 185°F)

5 to 95% (non-condensing)

Dimensions Standard: 5.20H x 2.07W x 4.52D in.

(13.2cmH x 5.25cmW x 11.48cmD)

Extended: 5.20H x 2.73W x 4.52D in.

(13.2cmH x 6.934cmW x 11.48cmD)

Specification Description

LED Indicators

Configuration Serial Port

Ethernet Port (Ethernet modules only)

Application Serial Ports

Serial Port Isolation

Shipped with Each Unit

Power and Module Status

Application Status

Serial Port Activity LED

Serial Activity and Error LED Status

DB-9M RS-232 only

No hardware handshaking

RJ45 Connector

Link and Activity LED indicators

RS-232/422/485

RS-232 handshaking configurable

RS-422/485 screw termination included

2500V RMS port signal isolation per UL

1577

3000V DC min. port to ground and port to logic power isolation

Mini-DIN to DB-9M serial cables

4 ft RS-232 configuration cable

2.5mm screwdriver

CD (docs and Configuration utility)

RS-422/485 DB-9 to Screw Terminal

Adaptor (1 or 4, depending on ports)

ProSoft Configuration Builder

ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.

Additional Products

ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.

Visit our web site at http://www.prosoft-technology.com for a complete list of products.

Ordering Information

To order this product, please use the following:

5102-MCM3-101S Modbus Master/Slave to IEC 60870-5-101

Slave Gateway

To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com

Distributors:

Place your order by email or fax to:

North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101

Europe [email protected], fax to +33 (0) 5.61.78.40.52

Copyright © ProSoft Technology, Inc. 2000 - 2007. All Rights Reserved.

May 03, 2007

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement