40rm007-034, 40rmq008-028 direct-expansion air

40RM-4SB
40RM007-034, 40RMQ008-028
DIRECT-EXPANSION
AIR-HANDLING UNIT
—
PERFORMANCE DATA
—
CERTIFIED DIMENSION PRINTS
—
FAN COIL ACCESSORY DIMENSION PRINTS
© Copyright 2001 Carrier Corporation • Syracuse, New York 13221
Form
40RM-4SB
Replaces 40RM-3SB
Printed in U.S.A.
6-01
Catalog No. 514-025
Date:
Supersedes:
40RM007-034,40RMQ008-016
DIRECT-EXPANSION AIR-HANDLING UNIT
JOB NAME:
LOCATION:
BUYER:
BUYER P.O.#
UNIT NUMBER:
MODEL NUMBER:
40RM/RMQ
Rev:
-4SB
CARRIER#
PERFORMANCE DATA CERTIFIED BY:
DATE:
DESCRIPTION
The 40RM fan coil units are a completely packaged unit offering the ultimate in installation ease and flexibility. Combined with Carrier 38 Series condensing units these fan coils offer system capacities from 6 to 30 tons.
These units may be installed in either the vertical or horizontal configuration with no modifications. Heating
capability is provided by electric heaters, hot water coils, steam coils, or if heat pump application is called for,
Carrier offers the 40RMQ units.
FEATURES
Easy maintenance — removal of a single panel allows access to
virtually all components.
Single blower on 6 to 10 ton units; dual blower on 121/2 to 30 ton
units.
24-volt terminal block for control wiring connection.
Standard one-year warranty.
Cleanable insulation treated with an anti-microbial agent.
Sloped condensate pans.
2-in. filters.
Powerful belt-driven forward curved fans.
Factory-installed fan motor and contactor.
Refrigerant metering device — factory-installed.
PERFORMANCE DATA
Total Cooling Capacity ____________________________ MBtuh
External Static Pressure_____________________________ in. wg
Sensible Cooling Capacity__________________________ MBtuh
RPM _________, BHP ____________
Air Quantity ________________________________________ Cfm
Saturated Suction Temperature __________________________ °F
Entering Air _________________ °F db _________________ °F wb
Total Heating Capacity ____________________________ MBtuh
ELECTRICAL DATA
Power Supply _____________________ Volts, ___________ Phase, __________ Hz
MOCP ______________________________ MCA __________________________
ACCESSORIES
2
(Field Installed)
Subbase for Vertical Applications
Free-Blow Discharge Plenum
Return Air Grille Panel
Overhead Suspension Brackets
Two-Row Hot Water Coil
One-Row Steam Distributing Coil
Economizer
Electric Heat _____________ Volts, ________________ kW
CO2 Sensor
Programmable Thermostat
Condensate Drain Trap
UV-C Germicidal Lamps
3
CUT ALONG DOTTED LINE
CERTIFIED DIMENSION PRINT
CUT ALONG DOTTED LINE
4
CERTIFIED DIMENSION PRINT
5
CUT ALONG DOTTED LINE
CERTIFIED DIMENSION PRINT
CUT ALONG DOTTED LINE
6
CERTIFIED DIMENSION PRINT
7
CUT ALONG DOTTED LINE
CERTIFIED DIMENSION PRINT
CUT ALONG DOTTED LINE
8
CERTIFIED DIMENSION PRINT
9
CUT ALONG DOTTED LINE
CERTIFIED DIMENSION PRINT
CUT ALONG DOTTED LINE
10
CERTIFIED DIMENSION PRINT
11
CUT ALONG DOTTED LINE
CERTIFIED DIMENSION PRINT
CUT ALONG DOTTED LINE
CERTIFIED DIMENSION PRINT
40RM007-034, 40RMQ 008-016 ELECTRIC HEAT ACCESSORY