13+SEER Environmentally Friendly 3 Speed Control Sleep Function

2007
www.comfortstarusa.com
13+SEER
Environmentally Friendly
3 Speed Control
Sleep Function
Easy Installation
Who we are
Our manufacturing facilities
maintain the highest quality
and reliability standards with
ISO9001 and ISO 14001.
All our products are
or
certified.
NOM-003-SCFI-2000
NOM-024-SCFI-1996
We provide solutions at
a great value.
Our ductless system is simple,
reliable and affordable.
Name you can trust…
We care about the environment
IAQ Indoor Air Quality
Standard active carbon electrostatic
fiber filter in all our mini-splits
• Traps small dust particles
• Smoke
•Pet dander
•Eliminates odors
All for your well being…
New environmentally friendly R410A
refrigerant in all heat pump units
• Reduces fossil fuel consumption and limits air pollution
•Prevents ozone layer depletion
Why use ComfortStar Plus Ductless System?
More than a 30% increase in energy efficiency in comparison to the 10 SEER unit, therefore reducing your utility bill and increasing savings.
SEER value up to 14.0 in cooling only units and 16.0 in heat pump units, this represents up to a 23% above the 2006 “13 SEER” efficiency mandate.
Environmentally friendly, reducing fossil fuel consumption and limiting air pollution. Heat pump units use environmentally friendly R410A refrigerant designed to prevent the depletion of the ozone layer.
High efficiency compressor and coil, increases the unit size by only 3 inches from the 10 SEER units. Heat pump units use Inverter Technology to achieve even higher efficiency in the smaller sizes.
Ductless systems provide less than 5% cooling loss which occurs in insulated refrigerant lines versus typical 40% loss through ducted systems.
www.comfortstarusa.com
Single zone comfort for residential and light commercial applications: schools, nursing homes, apartments, computer and telephone rooms.
Great for renovating or remodeling older homes.
Quieter than a window unit, mini-splits are comprised of an indoor and an outdoor unit, which keeps noisy compressors and motors outdoors.
Unlike window units, views will not be obstructed.
Burglar free. Intruders cannot climb in through openings. The indoor unit is connected to the outdoor unit through a small 3 inch opening on the wall.
Looks beautiful on the wall with the comfort of a remote control.
Same power source from indoor unit to outdoor unit.
Easy Installation
1.
2.
3.
Mount indoor and outdoor units.
Connect the refrigerant lines.
Make a few electrical connections.
Indoor Unit
Drain
Line
Outdoor Unit
Electric Line
Refrigerant Lines
www.comfortstarusa.com
NOM-003-SCFI-2000
NOM-024-SCFI-1996
NOM-003NOM-024-
Durability
The main cause for corrosion in air conditioning
equipment is due to the reaction of two metals:
Copper and Aluminum.
ComfortStar Plus 13 SEER has Gold Fin Protection
Gold Fin consists of two protective layers:
an anti-corrosive coating and a waterproof membrane
that prevents humidity. These ensure the durability of the
equipment and maximizes energy efficiency.
What is a Heat Pump?
A Heat Pump System can provide both cooling and heating to your home within one
system. During the heating season, heat pump moves heat from the cool outdoor into
your warm house; during the cooling season, heat pump moves heat from your cool
house into the warm outdoors. Heat pumps offer an energy-efficient alternative to a
furnace, because they move heat rather than generate heat. Our ComfortStar Plus Series
Heat Pumps can provide up to 3.1 times the amount of heat compared to a same size
electric heater.
Because our Heat Pump units use the latest INVERTER compressors all our units exceed
industry standards.
What is Inverter Technology?
At the heart of ComfortStar Plus Series Heat Pump system is the innovative inverter
technology. The Inverter Controlled Compressor operates by changing the frequency from
60Hz to a varying range (20Hz to 125 Hz). The inverter will control the compressor to
modulate on a high frequency and rapidly reach desired temperature. When the desired
temperature has been achieved, the inverter will control the compressor to run on a lower
frequency to maintain precise temperature and consume less energy.
TER
R
E
V
IN
ComfortStar Plus 13+SEER
www.comfortstarusa.com
Optimum Comfort
Inverter Controlled Compressor maintains precise control of room temperature and
creates a more comfortable environment. In conventional ON/OFF compressors, the
compressor turns OFF once the set temperature is reached, and turns back ON after
the temperature rises.
The time it takes for the unit
to switch on and off causes
the room temperature
to greatly fluctuate. With
the Inverter Controlled
Compressor, the power
reduces once the desired
temperature has been
reached, but continues
operating at a reduced state
to maintain a stable room
temperature with minimal
fluctuation.
Conventional
Inverter
1C
2C
Efficient Energy Use
With low-frequency operation,
the system reduces the energy
waste and provides the best
efficiency.
Máx. 44%
Less expensive electricity bills
Conventional
Inverter
Standard Features in all ComfortStar Plus
Active carbon electrostatic
fiber filter:
Auto restart and memory
function:
High Efficiency:
Golden fin:
Swing function:
24-hour timer:
A power failure will not cause any setting to be lost, thus eliminating the need
for re-programming.
With a high efficiency compressor and the most optimized heat exchange
system, the unit achieves higher efficiency and contributes to further energy
savings.
Coated with anti corrosion golden layer on the coils to improve hydrophilic
performance.
Allows the louver of the indoor unit to enhance the air distribution throughout
the room.
Allows the unit to start and stop as desired.
Sleep Function:
Adjusts the temperature while sleeping to make the room more comfortable.
3 Speed control:
Will change the fan speed to 3 different settings to accommodate your needs.
Dry mode:
Auto mode:
Error indicating light:
Overload Protection:
Anti-freezing Protection:
Low ambient control:
10
Electrostatic fiber filter traps small dust particles, smoke and pet dander to
prevent allergies. Active carbon filter eliminates odors.
Helps to control humidity levels when cooling may not be needed.
The system starts in high fan speed and automatically adjusts downward as
room reaches set temperatures.
Allows you to identify the problems within the system quickly and accurately.
Internal overload protector ensures compressor is running safely.
Pre-programmed control logic keeps coils from freezing.
By installing a head pressure control (not supplied), the unit can work down to
zero degrees.
ComfortStar Plus Series has it all…
www.comfortstarusa.com
R22 - Cooling Unit Specifications
MODEL
Feature
Power Supply
Rated Cooling
Capacity
CCH09CA-13 CCH012CA-13 CCH012CD-13 CCH018CD-13
Btu/h
SEER
for Cooling
Refrigerant/Charge
(Ounce)
Rated Current A
LRA of Compressor
Air Circulation
Noise Level
Indoor Unit
Fan Type
Fan Speed
(RPM)
Fan Motor
Output (W)
Outdoor Unit
Fan Type
Fan Speed (RPM)
Fan Motor
Output (W)
Compresor Type
Other
Filter
24 Hours Timer
Auto Restart
3 Speed Control
Auto Swing Louver
Suitable Area
(Sq.Ft.)
Outdoor IP Class
Lineset
Body Dimension
(Inches)
Cooling
Gas
Liquid
Indoor
Outdoor
NOM-003-SCFI-2000
NOM-024-SCFI-1996
Cooling Only
Cooling Only
Cooling
Cooling
115/1/60
115/1/60
230/1/60
230/1/60
9900
11700
11200
18500
14.1
13.6
14.1
13.5
R22/35
R22/46
R22/44
R22/67
7.7
8.9
4.2
6.4
49
53
26
39
427
388
492
706
51
51
51
51
Cross Flow Fan
Cross Flow Fan
Cross Flow Fan
Cross Flow Fan
1550/1450
/1350
1550/1450
/1350
1550/1450
/1350
1410/1310
/1260
20
20
20
35
Axial Fan
Axial Fan
Axial Fan
Axial Fan
885
885
900
780
48
48
48
60
Rotary
Rotary
Rotary
Rotary
Active Carbon
Active Carbon
Active Carbon
Active Carbon
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
330-495
390-585
400-600
600-900
IP24
IP24
IP24
IP24
1/2”
1/4”
35.71 x 11.4
x 7.68
1/2”
1/4”
35.71 x 11.42
x 7.68
1/2”
1/4”
35.71 x 11.42
x 7.68
5/8”
3/8”
46.38 x 12.84
x 8.94
33.38 x 21.27
x 12.6
33.38 x 21.27
x 12.6
33.38 x 21.27
x 12.6
37.0 x 33.07
x 16.22
NOM-003-SCFI-2000
NOM-024-SCFI-1996
11
R410A - Cooling & Heating Unit Specifications
MODEL
Feature
Power Supply
Rated Cooling
Capacity
Rated Heating
Capacity
CHH09CA-13 CHH012CA-13 CHH012CD-13 CHH018CD-13 CCH024CD-13
Heat Pump
Heat Pump
Heat Pump
Heat Pump
Heat Pump
115/1/60
115/1/60
230/1/60
230/1/60
230/1/60
Btu/h
10400
13900
13200
18400
23200
Btu/h
12800
14000
15900
20000
24500
16
16
15
13.2
14
8
7.7
7.7
7.7
8.4
R410A/42
R410A/44
R410A/44
R410A/62
R410A/84
6.4
8
9.5
11
7
7.2
5.98
8.23
9.8
9.95
33
33
33
27
40
450
500
500
900
1050
51
51
51
51
55
Cross Flow Fan
Cross Flow Fan
Cross Flow Fan
Cross Flow Fan
Cross Flow Fan
1200/1060
/860
1350/1200
/1100
1250/1100
/1050
1350/1300
/1250
1400/1300
/1250
14
20
20
21
35
Axial Fan
Axial Fan
Axial Fan
Axial Fan
Axial Fan
830
830
830
780/620
840/740
30
30
30
60
68
Inverter
Inverter
Inverter
Inverter
Inverter
Active Carbon
Active Carbon
Active Carbon
Active Carbon
Active Carbon
SEER
for Cooling
HSPF for Heating
Refrigerant/
Charge (Ounce)
Rated Current A
Cooling
Heating
LRA of Compressor
Air Circulation
Noise Level
Indoor Unit
Fan Type
Fan Speed
(RPM)
Fan Motor
Output (W)
Outdoor Unit
Fan Type
Fan Speed (RPM)
Fan Motor
Output (W)
Compresor Type
Other
Filter
24 Hours Timer
Auto Restart
3 Speed Control
Auto Swing Louver
Suitable Area
(Sq.Ft.)
Outdoor IP Class
Line Set
Body Dimension
(Inches)
12
Gas
Liquid
Indoor
Outdoor
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
346-520
463-695
440-660
613-920
773-1160
IP24
IP24
IP24
IP24
IP24
1/2”
1/4”
32.67 x 11.22
x 7.44
33.38 x 21.27
x 12.6
1/2”
1/4”
32.67 x 11.22
x 7.44
33.38 x 21.27
x 12.66
1/2”
1/4”
32.67 x 11.22
x 7.44
33.38 x 21.27
x 12.66
5/8”
3/8”
40.15 x 12.2
x 8.94
37.4 x 26.93
x 13.39
5/8”
3/8”
46.38 x 12.83 x
8.94
37.4 x 33.07 x
16.22
NOM-003-SCFI-2000
NOM-024-SCFI-1996
www.comfortstarusa.com
Remote control specifications
Remote control for Heat Pump
Turns unit ON/OFF.
Select desired modes
from Auto, Cool, Dry,
Fan and Heat.
3-Speed indoor fan;
Auto mode allows the
unit to cool quickly.
Room temperature
can be adjusted with
the interval of 1ºF.
Redirects air flow
automatically with up
and down motion.
To prevent excessive
cooling during sleep,
when the sleep function
is set, the room
temperature setting
will automatically rise
2ºF every hour. When
the temperature has
increased a total of 4ºF,
the unit will remain at
this setting.
Local time setting
and display.
Allows you to
program the
remote controller;
the system will
automatically turn
ON/OFF at the
desired time.
Actual size
13
Remote control specifications
Remote control for Cooling only
Redirects air flow
automatically with up
and down motion.
3-Speed control to
change fan speed.
Room temperature
can be adjusted from
61ºF to 86ºF.
Select desired
modes from Auto,
Cool, Dry and Fan.
Turns system ON/OFF.
Actual size
Outside View
14
www.comfortstarusa.com
Remote control specifications
Remote control for Cooling only
To prevent excessive
cooling during sleep,
when the sleep
function is set, the
room temperature
setting will increase
automatically 2ºF
every hour. When the
set temperature has
been increased a total
of 4ºF, the unit will
maintain this setting.
24 hour timer
allows you to
set the desired
time for unit to
automatically turn
OFF within a range
of 0.5h to 24h with
intervals of 0.5h.
24 hour timer
allows you to
set the desired
time for unit to
automatically turn
ON within a range
of 0.5h to 24h with
intervals of 0.5h.
Actual size
Inside View
15
Trademarks:
ComfortStar logo is a registered
brand of Eair, LLC/
Copyright © 2006 Eair, LLC
TY
N
WARRA
Heat Pump Disclaimer:
Heat Pump applications may
not be suitable for all climates.
Please consult installation
manual.
5compressor
Years
Certifications:
NOM-003-SCFI-2000
NOM-024-SCFI-1996
ComfortStar®
12201 N.W. 107th Ave.
Medley, FL 33178
Toll Free: 1-866-591-9898
Fax: 305-500-9896
www.comfortstarusa.com
NOM-003-SCFI-2000
NOM-024-SCFI-1996
1 Year
parts