IntelliComm

®

Communication Center

(For use with the IntelliFlo

®

and IntelliPro

®

pumps)

Installation Guide

IMPORTANT SAFETY INSTRUCTIONS

READ AND FOLLOW ALL INSTRUCTIONS

SAVE THESE INSTRUCTIONS

Technical Support

Contact Pentair Technical Support:

Sanford, North Carolina (8 A.M. to 5 P.M.)

Phone: (800) 831-7133

Fax: (919) 566-8920

Moorpark, California (8 A.M. to 5 P.M.)

Phone: (800) 831-7133 (Ext. 6502)

Fax: (805) 530-0194

Web sites:

visit www.pentairpool.com and www.staritepool.com

© 2008 Pentair Water Pool and Spa, Inc. All rights reserved

1620 Hawkins Ave., Sanford, NC 27330 • (919) 566-8000

10951 West Los Angeles Ave., Moorpark, CA 93021 • (805) 523-2400

IntelliFlo ® , IntelliPro ® , IntelliTouch ® , IntelliComm ® , Sta-Rite ® and the Pentair Water Pool and Spa ® are trademarks and/or registered trademarks of Pentair Water Pool and Spa, Inc. and/or its affiliated companies in the United States and/or other countries. Unless noted, names and brands of others that may be used in this document are not used to indicate an affiliation or endorsement between the proprietors of these names and brands and Pentair Water Pool and Spa, Inc. Those names and brands may be the trademarks or registered trademarks of those parties or others.

P/N 520700 Rev B - September 26 2008

Contents

IMPORTANT SAFETY PRECAUTIONS ............................................................... ii

Installation Steps Summary ..................................................................................... iv

Kit Contents ................................................................................................. iv

Required communication cable ................................................................... iv

Required Tools ............................................................................................. iv

IntelliComm Communication Center ....................................................................... 1

Installing the IntelliComm enclosure ........................................................................ 2

Mounting the IntelliComm enclosure ............................................................ 2

Connecting AC power wires to the IntelliComm ...................................................... 3

IntelliComm system wiring ...................................................................................... 4

IntelliComm electrical specifications ....................................................................... 4

Connecting the IntelliFlo communication cable ....................................................... 5

Connecting to IntelliComm ...................................................................................... 5

Wiring Diagrams ..................................................................................................... 6

4-speeds using IntelliTouch auxiliary relays ................................................. 6

2-speed using an IntelliTouch 2-speed relay ................................................ 7

Connection to Sta-Rite heater to set pump flow or speed when heater is running ................................................................................ 8 i

IntelliComm Communication Center Installation Guide

ii

IMPORTANT SAFETY PRECAUTIONS

He ad

Body pe

Up m

Leg J oin

Leg Joint

Important Notice:

Le g J oin

Leg Joint

This manual provides installation and operation instructions for the product. Consult

Pentair Water with any questions regarding this product.

Attention Installer: This manual contains important information about the installation, operation and safe use of this product. This information should be given to the owner and/or operator of this product after installation or left on or near this product.

Attention User: This manual contains important information that will help you in operating and maintaining this product. Please retain it for future reference.

WARNING

Read and follow all safety warning notices and instructions in this manual before installing this product. Failure to follow safety warnings and instructions can result in severe injury, death, or property damage. Call (800) 831-7133 for additional free copies of these instructions.

Read and Follow all Safety Instructions

This product is designed and manufactured for safe and reliable service when installed, operated and maintained according to the information and installation codes referred to in this manual.

This is a safety alert symbol. When you see this symbol in this manual or on the product, look for one of the following signal words; DANGER, WARNING, CAUTION and NOTICE and comply with the information. Be alert to the potential hazard. Ensure to read and comply with all of the warnings and cautions in this manual.

WARNING

Risk of electrical shock or electrocution!

The IntelliComm communication center must be installed by a licensed or certified electrician or a qualified pool serviceman in accordance with the

National Electrical Code (NEC) and all applicable local codes and ordinances.

Improper installation will create an electrical hazard which could result in death or serious injury to pool users, installers, or others due to electrical shock, and may also cause damage to property.

Always disconnect power to the IntelliComm communication center at the circuit breaker before servicing the pump. Ensure that the disconnected circuit is locked out or properly tagged so that it cannot be switched on while you are working on the pump. Failure to do so could result in serious injury or death to serviceman, pool users or others due to electric shock.

SAVE THESE INSTRUCTIONS

IntelliComm Communication Center Installation Guide

IMPORTANT SAFETY PRECAUTIONS

CAUTION

When using the IntelliComm communication center with the IntelliFlo pump, it is recommended to wire the IntelliComm power center to a ground fault circuitinterrupter (GFCI) to protect the circuit. A green colored terminal (or a wire connector marked “G”, “GR”, “Ground” or “Grounding”) is provided within the terminal compartment in the Power Center transformer enclosure. To reduce risk of electric shock, connect this terminal or connector to the grounding terminal of your electric service or supply panel with a conductor equivalent in size to the circuit conductors supplying this equipment.

WARNING

To reduce the risk of injury, service should only be attempted by a qualified Pool

Service Professional.

WARNING

To reduce the risk of injury, do not permit children to use this product unless they are closely supervised at all times.

CAUTION

The IntelliFlo pump is for use with permanently installed pools and may also be used with hot tubs and spas if so marked. Do not use with storable pools. A permanently installed pool is constructed in or on the ground or in a building such that it cannot be readily disassembled for storage. A storable pool is constructed so that it may be readily disassembled for storage and reassembled to its original integrity.

iii

SAVE THESE INSTRUCTIONS

IntelliComm Communication Center Installation Guide

iv

Installation Steps Summary

The recommended IntelliComm Communication Center installation steps are:

1

Review Important Safety Precautions (page i and ii): Review this important information.

2

Review IntelliComm Overview (page 1): Review the product overview.

3

Installing IntelliComm (page 2 ): Installing the IntelliComm enclosure.

4

Connecting the AC wires to IntelliComm (page 3 ): Connecting AC wires to terminal 1 and 2.

5

Connecting control input wires to IntelliComm (page 4 ): Connecting control input wires to terminals 3 to 10 from source devices such as automation controllers or heaters.

Kit Contents

IntelliComm Communication Center

IntelliComm Installation Guide (this manual)

Required communication cable

50 foot two wire RS-485 communication cable (P/N 350122). Used to communicate to the IntelliFlo pump from IntelliComm (see page 5)

Required Tools

Phillips and flathead screwdrivers (to mount the IntelliComm enclosure)

Electric drill and 1/4" masonry drill bit (to mount the IntelliComm enclosure)

IntelliComm Communication Center Installation Guide

IntelliComm Communication Center

The IntelliComm

®

communication center provides automatic control of IntelliFlo

®

and IntelliPro

®

pumps. The IntelliComm provides four pairs of input terminal connections. These inputs connectors are actuated by either 15 VAC to 240 VAC or

15 VDC to 100 VDC from the source device such as an automation controller, heater, or heat pump. If more than one input is active, the highest program number will be communicated to the pump.

Programming Flow Rates (GPM) for IntelliFlo VF and IntelliPro VF

The IntelliFlo VF and IntelliPro VF pump can be programmed to run at a specific US gallons per minute (GPM), for each external control input.

IntelliFlo VF: 15 - 130 GPM

IntelliPro VF:15 - 130 GPM

Programming Pump Speeds (RPM) for IntelliFlo VS+ SVRS, IntelliFlo VS3050 and IntelliPro VS3050

The IntelliFlo VS+ SVRS, IntelliFlo VS3050 and IntelliPro VS3050 pump can be programmed to run at a specific speed

(RPM), for each external control input.

IntelliFlo VS+ SVRS: 1100 - 3450 RPM

IntelliFlo VS3050: 400 - 3110 RPM

IntelliPro VS3050: 400 - 3450 RPM

1

Ground terminal

Attach incoming

IntelliComm AC power wires to AC terminals

1 and 2

Ground terminal

Attach control input wires to terminals 3 through 10

Attach IntelliFlo communication cable wires to terminals

11 and 12

IntelliComm Communication Center

IntelliComm Communication Center Installation Guide

2

Installing the IntelliComm enclosure

Install the IntelliComm enclosure at the equipment pad at a maximum of 50 feet from the pump. Leave sufficient clearance on all sides of the enclosure. Be sure that the 50 ft. communication cable from the pump can reach the IntelliComm enclosure location. The IntelliComm enclosure can be mounted on a wall or vertical flat surface up to 50 feet away from the cell controller.

CAUTION: The IntelliComm communication center must be installed more than 8 ft. (2.44 m) from the pool edges.

Note: For pump operating instructions, see the pump’s Installation and User’s Guide.

Mounting the IntelliComm enclosure

1. Using a medium flat blade screwdriver, loosen the two plastic screws on the front cover and open the front cover.

2. Mount the enclosure on a flat surface such as a wall or post. Mark each mounting screw hole location.

3. Drill four ¼ inch (6.35 mm) holes. Install anchors if necessary and one screw for each enclosure hole.

4. Position the enclosure in place over the holes and install the four mounting screws into the enclosure screw holes. Tighten the four screws to secure the enclosure.

Mounting screw access hole

Enclosure retaining screw

Enclosure retaining screw

Mounting screw access hole

IntelliComm Communication Center

IntelliComm Communication Center Installation Guide

Connecting AC power wires to IntelliComm

WARNING! IMPORTANT SAFETY PRECAUTIONS. BEFORE STARTING READ THE

FOLLOWING: Read all the safety precautions in this manual before attempting any electrical wiring. Be sure to read and follow all safety Instructions on page ii. Wiring

should only be performed by a qualified professional. When using electrical products,

basic precautions should always be followed, including the following:

• Grounding is required. The unit should be installed by a qualified service person and grounded.

To connect the AC power wires to IntelliComm:

1. Use 12-14 AWG three conductor insulated wire for the main AC power connection. Connect the main AC power wires to the IntelliComm AC terminals number 1 and 2 as shown below.

2.

Grounding: Attach incoming GROUND wire to the ground terminal as shown below. Earth grounding is necessary to ensure personal safety and safety of equipment.

3. Close the front cover and tighten the two cover screws.

3

Ground terminals

Attach incoming AC (100 VAC to 240 VAC 50/60 Hz) wires to AC terminals 1 and 2

IntelliComm Communication Center

IntelliComm Communication Center Installation Guide

4

IntelliComm system wiring

The IntelliComm provides four pairs of input terminals which can be actuated by either 15 to 240 VAC or 15 to 100 VDC from the source device, (automation controller, heater, heat pump etc.). There are four pump external control programs that can be enabled.

Note: The IntelliComm will always be configured to communicate to pump address 1.

IntelliComm system wiring table

T e r m i n a l n u m b e r T e r m i n a l n a m e

1 2 P o w e r s u p p l y

3 4

5 6

7 8

9 1 0

P r o g r a m 1

P r o g r a m 2

P r o g r a m 3

P r o g r a m 4

V o l t a g e

1 0 0 2 4 0 V A C

1 5

1 5 -

2 4 0

1 o r

0 0

V A C

V D C

1 5

1 5 -

2 4 0

1 o r

0 0

V A C

V D C

1 5

1 5 -

2 4 0

1 o r

0 0

V A C

V D C

1 5

1 5 -

2 4 0

1 o r

0 0

V A C

V D C

M a c u x i m u r r e n t m

1 0 0 m A

1 m A *

1 m A *

1 m A *

1 m A *

P h a s e t y p e

1 I n p u t

1 I n p u t

1 I n p u t

1 I n p u t

1 I n p u t

1 1

1 2

R S 4 8 5

+

-

D

D a t a : a t a :

Y e

G r e ll o w e n

5 t o + 5 V D C

5 m A 1 O u t p u t

F r e q u e n c y

5 0 / 6 0 H z

5 0 / 6 0 H z

5 0 / 6 0 H z

5 0 / 6 0 H z

5 0 / 6 0 H z

N / A

G r o u n d

Note: (*) indicates current controlled input, voltage independent.

IntelliComm electrical specifications

Power Requirements: The IntelliComm draws less than 1 amp. Over current protection of the wires connecting the source device, (automation controller, heater, heat pump etc.) to the IntelliComm must be provided at the source. This protection may be provided by a breaker, fuse or class 2-power supply. Example: A source with a 20 AMP supply breaker would require a minimum of 12 AWG wire.

Inputs from remote device: The IntelliComm has four current sensing inputs that are activated by either

15 VAC to 240 VAC or 15 VDC to 100 VDC.

Output to pump: The IntelliComm communicates with the pump via a two wire RS-485 cable.

IntelliComm Communication Center Installation Guide

Connecting the IntelliFlo communication cable

A two-wire optional communication cable (P/N 350122) is required to connect from the pump to IntelliComm. This allows the pump to be controlled by IntelliComm. The cable pinout is shown below.

IntelliFlo communication cable pinout

5

Pin 6 (Green) RS-485 (N)

Note: Pins 1 - 5 are not used.

Pin 7 (Yellow) RS-485 (P)

Connecting to IntelliComm

The following wiring diagrams show how to connect a source device to IntelliComm that will enable the pump programs. If more than one source input is active, the highest program number is given priority to communicate to the pump.

Wiring Diagrams

4-speeds using IntelliTouch

®

auxiliary relays (page 6): This wiring diagram shows how the IntelliComm can be used to control four IntelliFlo or IntelliPro external control programs. The example uses four auxiliary relays in an

IntelliTouch automation controller. Auxiliary relays from other automation controllers would be wired similarly. Wire the IntelliTouch relay contacts as shown. The controller would then be configured so that each auxiliary relay energizes when a certain flow or speed is required.

2-speed using an IntelliTouch 2-Speed relay (page 7): This wiring diagram shows how the IntelliComm, in conjunction with an IntelliFlo or IntelliPro pump, can be used to replace an existing 2-speed application.

• Connection to Sta-Rite ®

heater to set pump flow or speed when heater is running (page 8): This wiring diagram shows how the IntelliComm can be used to command an IntelliFlo or IntelliPro pump to run at a specific speed or flow rate when the heater is running.

IntelliComm Communication Center Installation Guide

6

4-speeds using IntelliTouch auxiliary relays

IntelliComm

PRGM

1

PRGM

2

PRGM

3

PRGM

4

RS485 +

RS485 -

POWER

5

6

7

8

3

4

1

2

9

10

11

12

GND

YEL

GRN

100 to 240 VAC

Power Supply

IntelliTouch Panel

Aux. 1

Relay

115 VAC from circuit breaker

HOT NEUTRAL

Aux. 2

Relay

Aux. 3

Relay

Aux. 4

Relay

230 VAC

Power to

Pump

IntelliFlo

Drive

Low Volt

Comm

Cable

IntelliComm Communication Center Installation Guide

2-speed using an IntelliTouch 2-speed relay

230 VAC

Power to

Pump

IntelliComm

PRGM

1

PRGM

2

PRGM

3

PRGM

4

RS485 +

RS485 -

POWER

10

11

12

7

8

9

4

5

6

1

2

3

GND

YEL

GRN

100 to 240 VAC

Power Supply

Low Volt

Comm

Cable

IntelliFlo

Drive

IntelliTouch Panel

Filter Pump

Relay

115 VAC from circuit breaker

HOT NEUTRAL

2-Speed Relay

7

IntelliComm Communication Center Installation Guide

8

Connection to Sta-Rite heater to set pump flow or speed when heater is running

Starite Heater

IntelliComm

PRGM

1

PRGM

2

PRGM

3

PRGM

4

RS485 +

RS485 -

POWER

1

6

7

8

9

2

3

4

5

10

11

12

GND

YEL

GRN

100 to 240 VAC

Power Supply

IntelliFlo

Drive

Low Volt

Comm

Cable

230 VAC

Power to

Pump

IntelliComm Communication Center Installation Guide

LIMITED WARRANTY

Pentair Water Pool and Spa, Inc. ("Pentair Water") manufactures its products with the highest standards of workmanship, using the best materials available through state of the art process. Pentair Water warrants its products as follows:

Limited Warranty: Pentair Water warrants its products to be free from defects in material and/or workmanship for a period of one (1) year.

Exceptions that could result in denial of a warranty claim:

1. Damage caused by careless handling, improper repackaging, or shipping.

2. Damage due to misapplication, misuse, abuse or failure to operate equipment as specified in the owners manual.

3. Damage caused by failure to install products as specified in the owners manual.

4. Damage due to unauthorized product modifications or alterations, or failure to use Pentair Water original replacement parts.

5. Damage caused by negligence, or failure to properly maintain products as specified in the owners manual.

6. Damage caused by failure to maintain water chemistry in conformity with the standards of the swimming pool industry for any length of time.

7. Damage caused by water scaling, freezing or other conditions causing inadequate water circulation.

8. Accidental damage, fire, acts of God, or other circumstances outside the control of Pentair Water.

• This warranty extends to the original retail owner only, beginning on the date of installation and is not enforceable by any other party. Proof of purchase and/or date of installation will be required to execute a warranty claim. Original owner agrees to repay all shipping charges to Pentair Water Pool and Spa Inc.

• Warranties by others: Some products incorporate components manufactured by other manufacturers. Some of these provide warranties in addition to the warranty provided herein. In all such cases a copy of that warranty will be provided with the product. To the extent protection provided under any such third party warranty exceeds the Limited Warranty provided herein, the Customer will have to look to that manufacturer for the additional warranty protection.

Warranty Obligations of Pentair Water: Should a defect in workmanship and/or material in any item covered by this warranty become evident during the term of the warranty, then upon the consumer following the procedures set forth below, Pentair Water will, at its option, repair or replace such item or part at its own cost and expense.

Pentair Water is not, however, responsible under this warranty for any cost of shipping or transportation of the equipment or parts thereof to or from the Technical Service Department. Also, Pentair Water is not liable for any loss of time, inconvenience, incidental expenses such as telephone calls, labor or material charges incurred in connection with the removal or replacement of the equipment, or any other incidental or consequential damages.

PLEASE NOTE: Some states do not allow the exclusion or limitation of incidental, or consequential damages, so the above limitation or exclusion may not apply to you.

No Other Warranties: TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, PENTAIR WATER DISCLAIMS

ALL OTHER WARRANTIES, WHETHER EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO THE IMPLIED

WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.

Procedure for Obtaining Performance: In order to obtain the benefits of this warranty, the consumer who made the original retail purchase must contact the Pentair Water Technical Service Department upon discovery of the defect, but in no event later than the expiration date of the warranty period provided in this warranty. Upon receipt of this communication, Pentair Water will promptly notify the customer of the address to which the defective item may be shipped. The customer shall then ship the item, freight prepaid, to the address indicated, together with a "RETURN

GOODS AUTHORIZATION" form obtained from Technical Service and a brief description of the problems encountered.

Unauthorized returns will not be accepted. Freight must be prepaid by customer.

Warranties or Representations by Others: No dealer or other person has any authority to make any warranties or representations concerning Pentair Water or its products. Accordingly, Pentair Water is not responsible for any such warranties or representations.

Other Rights: This warranty gives you specific legal rights and you may also have other rights, which vary from state to state. This warranty supersedes all previous publications.

PENTAIR WATER POOL AND SPA, INC.

1620 Hawkins Ave. Sanford, NC 27330 - 10951 W. Los Angeles Ave. Moorpark, CA 93021 - Phone 800-831-7133 - Fax 800-284-4151

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals