Ambiance Fireplaces INT-200 Installation and Operating manual

Add to My manuals
48 Pages

advertisement

Ambiance Fireplaces INT-200 Installation and Operating manual | Manualzz

INSTALLATION AND OPERATING MANUAL

Intrigue Series

Direct Vent Gas Fireplaces

Models: #INT-100

#INT-200

INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE.

CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE

.

This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or mobile home where not prohibited by local codes.

This appliance is only for use with the type of gas indicated on the rating plate.

This appliance is not convertible for use with other gases, unless a certified kit is used.

WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result, causing property damage, personal injury or loss of life.

— Do not store or use gasoline or other flammable vapors and liquids in the

vicinity of this or any other appliance.

WHAT TO DO IF YOU SMELL GAS:

◙ Do not light any appliance.

◙ Do not touch any electrical switch: do not use any phone in your building.

◙ Immediately call gas supplier from a neighbors phone. Follow the gas

supplier instructions.

◙ If you cannot reach your gas supplier, call the fire department.

— Installation and service must be performed by a qualified installer, service

agency or the gas supplier.

WARNING

HOT GLASS WILL CAUSE BURNS.

DO NOT TOUCH GLASS UNTIL COOLED.

NEVER ALLOW CHILDREN TO TOUCH GLASS.

Report No. 216-S-35-6.5

SEPT 2011 INT-REV-04

TABLE OF CONTENTS

TABLE OF CONTENTS

Table of Contents

SAFETY INFORMATION

Safety Information

COMMONWEALTH OF MASSACHUSETTS INFORMATION

Commonwealth of Massachusetts Information

SPECIFICATIONS

Fireplace Dimensions

Clearances

Components List

Installation Overview

Placement Clearance Requirements

PREPARE THE FIREPLACE

Stand-Off Assembly & Installation

Horizontal Vent Heat Shield Installation

Nailing Flange Assembly & Installation

FRAMING

Wall Enclosure Rough Opening

Minimum Finished Opening Dimensions

Horizontal Terminations

Vertical Terminations

TYPICAL INSTALLATION OPTIONS

Typical Installation Options

MANTEL REQUIREMENTS

Mantel Requirements

GLASS FRAME ASSEMBLY

Glass Frame Assembly Removal

Glass Frame Assembly Installation

GAS LINE CONNECTION

Gas Line Connection

LIGHT KIT COMPONENTS INSTALLATION (INT-200)

Light Kit Components Installation (INT-200)

VENTING

Approved Venting

Horizontal Vent System Clearances

Horizontal Termination Minimum / Maximum

Elbows

Horizontal Venting Illustrations

Vertical Vent System Clearances

Restrictor

Horizontal / Vertical Combination Venting

Vertical Illustrations

1

2

3

10

11

11

11

14

15

15

15

13

13

13

13

16

5

5

4

4

5

12

12

9

9

8

8

6

7

7

VENTING (cont.)

Restrictor Installation

Horizontal & Vertical Combination Venting Illustration

Termination Vent Cap Location

Vent Termination Clearances

LOG SET INSTALLATION

Log Set Installation

CONTROL BOARD

Control Board Removal

Control Board Installation

GRILL SET

Grill Set Installation

Grill Set Removal

OPERATING INSTRUCTIONS

Wiring Schematics

Valve and Pilot Assembly Components

Control Module Components

Remote Control Components

Information and Remote Control Operation

Lighting and Shutdown

Pressure Testing

Error Codes

FINALIZING THE INSTALLATION

Burner Tube Adjustment / Troubleshooting

Restrictor Troubleshooting / Installation after Termination Completion

MAINTENANCE

Maintenance

TROUBLESHOOTING

Troubleshooting

CONVERSION KIT INSTRUCTIONS

Conversion Kit Instructions

#INT-060 OPTIONAL UPGRADE KIT FOR INT-100

#INT-060 Optional Upgrade Kit for INT-100

REPLACEMENT PARTS LIST

Replacement Parts List

WARRANTY

Warranty

39-40

41-42

43-44

16

17

18

19

20

21

22

23

23

24

25

26

27

28-31

32-33

34

35

36

37

38

45

46-47

PAGE 1

SAFETY INFORMATION

This fireplace has been tested to and complies with ANSI Z21.88-2009 / CSA 2.33-2009 “VENTED GAS FIREPLACE HEATERS” and

Testing Method for Measuring Annual Effiency, CSA P.4.1-09 by OMNI-Test Laboratories, Portland, OR. Installation must conform with local building codes or in the absence of local building codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54 - Current Edition, or the Natural

Gas and Propane Installation Code, CSAB149.1

Installation and repair should be done only by a qualified service person. The appliance should be inspected by a qualified service person before use. Annual inspection by a qualified service person is required to maintain warranty.

More frequent cleaning may be required due to excessive lint from carpeting, bedding materials, etc. It is imperative that control compartments, burners and circulation air passageways of the appliance be kept clean.

If this appliance is installed directly on carpeting, tile or other combustible material other than wood flooring, the appliance shall be installed on a metal or wood panel extending the full width and depth of the appliance.

Children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition.

Young children should be carefully supervised when they are in the same room as the appliance. Toddlers, young children and others may be susceptible to accidental contact burns. A physical barrier is recommended if there are at risk individuals in the house. To restrict access to a fireplace or stove, install an adjustable safety gate to keep toddlers, young children and other at risk individuals out of the room and away from hot surfaces.

Clothing or other flammable material should not be placed on or near the appliance.

Adequate accessibility clearances for servicing and proper operation must be maintained.

This appliance must not share or be connected to a chimney flue serving any other appliance.

Keep area around the appliance clear of combustible materials, gasoline and other flammable vapor and liquids.

The flow of combustion and ventilation air must not be obstructed.

Due to high temperatures the appliance should be located out of traffic and away from furniture and draperies.

The glass front or any part removed for servicing the appliance must be replaced prior to operating the appliance.

Work should be done by a qualified service technician.

Clean glass only when cool and only with non-abrasive cleansers.

WARNING: DO NOT OPERATE APPLIANCE WITH THE GLASS/FRAME ASSEMBLY REMOVED, CRACKED

OR BROKEN. REPLACEMENT OF THE GLASS SHOULD ONLY BE PERFORMED BY A LICENSED OR

QUALIFIED SERVICE PERSON.

The glass assembly, Part #INT-057T, shall only be replaced as a complete unit, as supplied by Hussong Mfg. Co., Inc.

DO NOT SUBSTITUTE MATERIALS.

Do not strike or slam glass assembly.

Any safety screen or guard removed for servicing the appliance must be replaced prior to operating the appliance.

Under no circumstances should any solid fuel (wood, coal, paper or cardboard etc.) be used in this appliance.

Keep burner and control compartment clean.

Do not use this fireplace if any part has been under water. Immediately call a qualified service technician to inspect this appliance and to replace any part of the control system and any gas control which has been under water.

PAGE 2

COMMONWEALTH OF MASSACHUSETTS REQUIREMENTS

NOTE: The following requirements reference various Massachusetts and national codes not contained in this manual.

For all sidewall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than (7) feet above finished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall be satisfied:

INSTALLATION OF CARBON MONOXIDE DETECTORS

At time of installation of side wall horizontally vented gas fueled equipment, the installing plumber or gas-fitter shall observe that a hard wired carbon monoxide detector with an alarm and battery back-up is installed on the floor level where the gas equipment is to be installed. In addition, the installing plumber or gas-fitter shall observe that a battery operated or hard wired carbon monoxide detector is installed on each additional level of the dwelling, building or structure served by the side wall horizontal vented gas fueled equipment. It shall be the responsibility of the property owner to secure the services of qualified licensed professionals for the installation of hard wired carbon monoxide detectors.

In the event that the side wall horizontally vented gas fueled equipment is installed in a crawl space or attic, the hard wired carbon monoxide detector with alarm and battery back-up may be installed on the next adjacent floor level.

In the event that the requirements of this subdivision can not be met at the time of completion of installation, the owner shall have a period of thirty (30) days to comply with the above requirements; provided, however, that during said thirty (30) day period, a battery operated carbon monoxide detector with an alarm shall be installed.

APPROVED CARBON MONOXIDE DETECTORS

Each carbon monoxide detector as required in accordance with the above provisions shall comply with NFPA 720 and be ANSI/UL 2034 listed and IAS certified.

SIGNAGE

A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a minimum of eight (8) feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment. The sign shall read, in print no less the one-half inch

(1/2) in size, “GAS VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OBSTRUCTIONS”.

INSPECTION

The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless, upon inspection, the inspector observes carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR 5.08 (2) (a) 1 through 4.

EXEMPTIONS

The following equipment is exempt from 248 CMR 5.08 (2) (a) 1 through 4:The equipment listed in Chapter 10 entitled “Equipment Not Required To Be

Vented” in the most current edition of NFPA 54 as adopted by the Board; and Product Approved side wall horizontally vented gas fueled equipment installed in a room or structure separate from the dwelling, building or structure used in whole or in part for residential purposes.

MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM PROVIDED

When the manufacturer of Product Approved side wall horizontally vented gas equipment provides a venting system design or venting system components with the equipment, the instructions provided by the manufacturer for installation of the equipment and the venting system shall include:

Detailed instructions for the installation of the venting system design or the venting system components; and

A complete parts list for the venting system design or venting system.

MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM NOT PROVIDED

When the manufacturer of Product Approved side wall horizontally vented gas equipment does not provide the parts for venting the flue gases, but identifies

“special venting systems”, the following requirements shall be satisfied by the manufacturer:

The referenced “special venting systems” instructions shall be included with the appliance or equipment installation instructions and;

The “special venting systems” shall be Product Approved by the Board, and the instructions for that system shall include a parts list and detailed installation instructions.

A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment, all venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation.

PAGE 3

DESCRIPTION Height

INCHES

FIREPLACE

DIMENSIONS

MILLIMETERS

34-1/2

876

Width

40-7/8

1038

SPECIFICATIONS

FIREPLACE DIMENSIONS

Back Width Depth Opening

Width

Glass Frame

Height

Stand-off

Height

Front to

Angled Back

30-3/8

772

19

483

35-1/2

902

26-5/8

676

10

254

Front to Vent

Center

(Vert. Term.)

16-1/8

410

Floor to Vent

Center

(Hor. Term.)

32-3/8

848

7-7/8

200

WARNING: Top stand-off bracket must be attached to fireplace. Do not remove. Stand-off brackets are not load bearing.

Non-combustible zone: Stand-offs provide 10” (254mm) minimum clearance to header. Use only non-combustible material

in this area for entire width of fireplace. Do not use wood, sheetrock etc. in this zone. Other clearances apply. All clearances

must be maintained.

10"

254mm

44 1

2

"

1130mm

RIGHT SIDE

33 3

8

"

848mm

4 1

4

"

108mm

8 5

8

"

219mm

16 1

8

"

410mm

34

1

2

"

876mm

FRONT

35

1

2

"

902mm

40

7

8

"

1038mm

30 3

8

"

772mm

26

5

8

"

676mm

19"

483mm

7 7

8

"

200mm

LEFT SIDE

2 1

8

"

54mm

6 1

2

"

165mm

Figure 4a

2 7

8

"

73mm

CLEARANCES

Top of unit face to header (cement board may be used in this area).

10” (254mm)

From unit left & right sides and back 1/2” (13mm)

To flooring

Unit top to ceiling

0” (0mm)

31” (787mm)

Side of unit face to adjacent sidewall

Mantel 9” (229mm) deep from top of fireplace

3” (76mm)

12-1/2” (318mm)

Top of fireplace to 1” (25mm) trim 10” (254mm)

PAGE 4

INT-100 COMPONENTS LIST

PART NUMBER

INT-600-IPI

700-203

INT-135

DESCRIPTION

IPI Control Board Assembly

Manual Gas Shut-off Valve

Burner Assembly

INT-G900

INT-500

600-002

Refractory Set (back and sides)

Log Package

INT-057T Glass Frame Assembly

OCK-A5163L-I-INT-PSE LP Conversion Kit

Double Receptacle Assembly

942-085

500-TRF

INT-208

5” Restrictor Plate

4 pc. Grill Assembly

Remote Control

SPECIFICATIONS

INT-200 COMPONENTS LIST

PART NUMBER

INT-600-IPI

700-203

INT-135

DESCRIPTION

IPI Control Board Assembly

Manual Gas Shut-off Valve

Burner Assembly

INT-G900

INT-500

INT-057T

Refractory Set (back and sides)

Log Package

Glass Frame Assembly

OCK-A5163L-I-INT-PSE LP Conversion Kit

600-002

942-085

500-TRF

INT-208

Double Receptacle Assembly

5” Restrictor Plate

4 pc. Grill Assembly

Remote Control

INT-RLK Light Kit

INT-028 Fan Kit

INSTALLATION OVERVIEW

NOTE: The qualified installer should follow the procedure best suited for the installation.

1. Frame an opening for the fireplace, allowing for vent installation (top or rear) and type of installation (corner or flat wall application).

2. If masonry (optional) is used, prepare foundation for the masonry load. A lintel is required to support the added weight above fireplace.

3. Attach nailing flanges to fireplace.

4. Insert fireplace into framing.

5. Install hearth (if applicable).

6. Complete electrical hook-up. Install any standard or optional electrical components at this time.

7. Complete gas line installation.

8. Complete venting installation.

9. Secure fireplace to flooring through holes in outer box bottom and to framing with nailing flanges. Verify all clearances at this point.

10. Install facing material, mantel or cabinetry, allowing room for optional full face doors, if applicable.

11. Install logs.

12. Install grills and optional decorative doors / faces.

13. Verify proper operation of fireplace and all components.

PLACEMENT CLEARANCE REQUIREMENTS

This fireplace must be installed on a level surface capable of supporting the fireplace and venting.

Fireplace must be placed directly on wood or non-combustible surface (not linoleum or carpet) extending entire depth and width of fireplace.

Due to high surface temperatures, fireplace should be located out of traffic and away from furniture and draperies.

This fireplace may be installed in a bedroom.

Please be aware of the large amount of heat this fireplace will produce when determining a location.

PAGE 5

PREPARE THE FIREPLACE

STAND-OFF ASSEMBLY & INSTALLATION

WARNING: Top stand-off brackets and stand-off heat shields must be attached to fireplace. Do not remove.

These items are not load bearing.

Non-combustible zone: Stand-offs provide 10” (254mm) minimum clearance to header. Use only non-combustible material

in this area for entire width of fireplace. Do not use wood, sheetrock etc. in this zone. Other clearances apply. All clearances

must be maintained.

Top stand-off brackets and stand-off heat shields are attached to fireplace top in a flat state for shipping.

1. Remove and save (4) screws securing stand-off heat shields and stand-off brackets, and (4) screws located under these items.

2. Form stand-off brackets as shown and re-attach to fireplace using screws previously removed.

3. Form stand-off heat shields and attach to stand-off brackets using (8) screws provided in components packet. (Stand-off heat shield flanges face up and to front of fireplace).

STAND-OFF BRACKETS AS SHIPPED

FORM STAND-OFF BY BENDING AT PERFORATIONS

FORMED STAND-OFF

REMOVE SCREWS SECURING STAND-OFF BRACKETS

STAND-OFF BRACKETS

INSTALLED

STAND-OFF HEAT

SHIELDS INSTALLED

ALIGN HOLES IN FORMED STAND-OFFS WITH HOLES IN

FIREPLACE TOP. SECURE WITH (4) SCREWS.

Figure 6a

ALIGN HOLES IN FORMED STAND-OFF HEAT SHIELDS WITH

HOLES IN STAND-OFF BRACKETS. SECURE WITH (8) SCREWS.

PAGE 6

PREPARE THE FIREPLACE

HORIZONTAL VENT HEAT SHIELD INSTALLATION

IMPORTANT: The horizontal vent heat shield must be installed when using a 45-degree elbow to horizontally position the vent system.

EXCEPTION: Corner installations

1. Loosen, but do not remove center three screws at back of fireplace as shown.

2. Bend horizontal heat shield at perforation to a 45° angle. Slide (3) slots on horizontal vent heat shield under loosened screws. Re-tighten screws.

Attach here.

Figure 7a

NAILING FLANGE ASSEMBLY & INSTALLATION

1. Remove (4) nailing flanges from fireplace sides.

2. With the 1/2” (13mm) stand-offs on nailing flanges facing away from fireplace, align nailing flange with holes on outside corners of fireplace. Secure with screws through slots in nailing flanges (additional screws provided in components packet).

3. Bend perforation on nailing flange until parallel with fireplace face. Do not bend toward fireplace face.

4. Position framing stud against 1/2” (13mm) stand-off (located on backside of nailing flange). Secure with nails or screws.

NOTE: Depending on facing material, tabs can be adjusted forward or back up to 1/2” (13mm).

CAUTION: NEVER PERMANENTLY REMOVE THESE ASSEMBLIES FROM FIREPLACE - THEY MUST BE SECURED IN PLACE REGARDLESS OF

FINISH MATERIAL USED.

When installed, nailing flanges provide minimum 1/2” (13mm) clearance from fireplace sides.

FRONT VIEW

1/2” (13mm)

CLEARANCE

STAND-OFF

NAILING FLANGE

AS SHIPPED

NAILING FLANGES

INSTALLED

FRAMING STUD

TOP VIEW

1/2” (13mm)

CLEARANCE

STAND-OFF

FRAMING STUD

Figure 7a NAILING FLANGE

PAGE 7

FRAMING

WALL ENCLOSURE ROUGH OPENING

IMPORTANT: Framing dimensions should allow for wall covering thickness and fireplace facing materials. If using a hearth, adjust

rough opening size as necessary to maintain at least minimum clearance requirements.

IMPORTANT: Non-combustible facing material may be applied over (but not directly to) fireplace face. This will prevent facing material

from falling off due to heat expansion. Do not obstruct the flow of ventilation air.

MINIMUM FINISHED OPENING DIMENSIONS

HORIZONTAL TERMINATION: 44-1/2”(1130mm) High x 41-3/8”(1051mm) Wide x 21-1/2” (546mm) Deep.

1/2” (13mm) clearance at back and sides of fireplace must be maintained.

VERTICAL TERMINATION: 44-1/2”(1130mm) High x 41-3/8”(1051mm) Wide x 21-1/2” (546mm) Deep.

1/2” (13mm) clearance at back and sides of fireplace must be maintained.

NOTE: Provide adequate clearance in front of fireplace to operate lower grill, open and close optional full door face doors, access

components, installation of gas line, fan, etc. See Figure 8b.

WARNING: Provide adequate clearances around air openings into the combustion chamber.

Do not obstruct upper and lower grill openings. Room air enters through lower passage, is heated and exits through upper passage.

Blocking these passages may result is overheating, creating a potentially hazardous situation.

Refer to vent manufacturer installation instructions to determine vent framing dimensions.

OPTIONAL FULL DOOR FACE DIMENSIONS

If installing an optional full door face, please refer below for full face dimensions before applying facing material.

NOTE: Consider height of hearth finish material (stone, brick,

marble etc.) when building fireplace platform. Bottom

of fireplace must be level with finished hearth to allow

for lower grill operation and proper fit of optional

decorative full door faces.

NOTE: 1/2” (13mm) side overlap applies to both sides of face.

Illustrations show True Dimensions. We recommend

1/4” (6mm) clearance on all sides to allow for uneven

finish material.

41-3/4”

(1060mm)

44-1/2”

(1130mm)

41-3/8”

(1051mm

36-5/32”

(918mm)

Hearth

Height

Minimum:

21-1/2”(546mm)

Figure 8a

PAGE 8

Figure 8b

FRAMING

Determine exact position of your fireplace, including hearth height, width, and depth, (if applicable). If possible, place fireplace in such a manner that vent termination will be placed between two studs, eliminating the need for additional framing.

If masonry is to be used (optional), prepare the necessary foundation for the masonry load. When masonry construction is used, a lintel must be used over top of fireplace to support the added weight.

Build hearth to desired size and height. If a hearth extension is desired, combustible material may be used.

NOTE: Consider height of hearth finish material (stone, brick, etc.) when building fireplace platform. Bottom of fireplace must be level

with finished hearth to allow for lower grill operation and proper fit of optional decorative full door faces.

WARNING: Install fireplace on hard metal or wood surface extending the full width and depth of fireplace.

Minimum platform size: 40-7/8” (1038mm) wide x 19” (483mm) deep.

FIRE HAZARD: Do NOT install directly on carpeting, vinyl, or any combustible material other than wood.

IMPORTANT: Vent cap location must be in compliance with guidelines on page #18 of this manual.

HORIZONTAL TERMINATIONS

Follow vent pipe manufacturer‟s installation instructions for horizontal terminations. Include required vent manufacturer‟s wall pass-thru clearances when determining framing dimensions.

MINIMUM HORIZONTAL FRAMING DIMENSIONS

VENT PIPE CENTER (A) FRAMED OPENING TOP (B)

RIGID PIPE 33-3/8” (848mm) Per vent manufacturer requirements

FLEX PIPE 36-7/8” (937mm) Per vent manufacturer requirements

VERTICAL TERMINATIONS

Follow vent pipe manufacturer‟s installation instructions for vertical terminations. A minimum 1” (25mm) clearance on all sides of vertical vent pipe must be maintained.

NOTE: The included Horizontal Vent Heat Shield is not used for

vertical configurations.

Figure 9a

CAUTION: Cold air transfer area. The surrounding fireplace chase must comply with all clearances as outlined in this manual and be constructed in compliance with local building codes. Outside walls should be insulated to prevent cold air from entering room.

CAUTION: Due to high temperatures, this fireplace should be located out of traffic areas and away from furniture and draperies.

PAGE 9

TYPICAL INSTALLATION OPTIONS

IMPORTANT: The horizontal heat shield included with this fireplace must be installed when using a 45-degree elbow directly off top

of unit to horizontally position vent system. EXCEPTION: Corner installations.

NOTE: HORIZONTAL VENT HEAT SHIELD NOT SHOWN FOR CLARITY PURPOSES ONLY.

TYPICAL HORIZONTAL INSTALLATION

Figure 10a

Figure 10b

Figure 10c

1

2

"

13mm 19 "

495mm

41 3

8

"

1051mm

TYPICAL CORNER INSTALLATION

1

2

"

13mm

34 7

8

"

886mm

1

2

"

13mm

49 1

4

"

1251mm

69 3

4

"

1772mm

TYPICAL VERTICAL INSTALLATION

2"

51mm

1"

25mm

21"

533mm

41 3

8

"

1051mm

PAGE 10

MANTEL REQUIREMENTS

WARNING: TOP STAND-OFF BRACKETS MUST BE ASSEMBLED AND ATTACHED TO FIREPLACE. DO NOT REMOVE.

STAND-OFF BRACKETS ARE NOT LOAD BEARING.

NON-COMBUSTIBLE ZONE:

Rigid pipe: 1” (25mm) above elbow for entire width and depth (behind header) of fireplace.

Flexible venting: 1” (25mm) above elbow for entire width and depth (behind header) of fireplace.

NON-COMBUSTIBLE ZONE:

No materials allowed on top of fireplace within shaded area for the entire width and depth of fireplace. This air space must remain open.

13" (330mm)

11" (279mm)

9" (229mm)

16 1

2

"

419mm

14 1

2

"

368mm

12 1

2

"

318mm

10"

254mm

13 1

2

"

343mm

1"

25mm

NON-COMBUSTIBLE MATERIAL ONLY

HORIZONTAL VENT HEAT

SIDE VIEW

Figure 11a

GLASS FRAME ASSEMBLY

CAUTION: TO PREVENT GLASS FRAME ASSEMBLY FROM FALLING FROM FIREPLACE AND BECOMING DAMAGED, FOLLOW THESE

INSTRUCTIONS EXACTLY WHEN REMOVING AND INSTALLING GLASS FRAME ASSEMBLY.

REMOVE GLASS FRAME ASSEMBLY

1. Locate spring-loaded handles securing glass frame assembly at top & bottom of firebox.

2. Pull bottom handles out and down to release glass frame assembly bottom.

3. Pull top handles out and up to release glass frame assembly top.

INSTALL GLASS FRAME ASSEMBLY

1. Making sure wide lip of glass frame assembly is at bottom and narrow lip at top, place assembly onto fireplace front.

2. Pull top handles out and down to secure glass frame assembly top.

3. Pull bottom handles out and up to secure glass frame assembly bottom.

Narrow lip at top of glass frame assembly.

Pull latches out and up to release glass frame assembly top.

Pull latches out and down to attach glass frame assembly top.

Pull latches out and down to release glass frame assembly bottom.

Pull latches out and up to attach glass frame assembly bottom.

Figure 11b

Wide lip at bottom of glass frame assembly.

PAGE 11

GAS LINE CONNECTION

GAS CONVERSION

This fireplace is manufactured for use with Natural Gas. An LP conversion kit, is included with this fireplace. Follow instructions included with conversion kit if converting to LP gas.

ATTENTION: The conversion shall be carried out in accordance with the requirements of US or Canadian authorities having local

jurisdiction and in accordance with the requirements of the ANSI Z223.1 installation code.

CAUTION: Installation of the gas line must only be done by a qualified person in accordance with local building codes, if any.

If not, follow ANSI 223.1.

Commonwealth of Massachusetts: Installation must be done by a licensed plumber or gas fitter.

NOTE: A listed (and Commonwealth of Massachusetts approved) 12” (13mm) T- handle manual shut-off valve and flexible gas

connector (included) are connected to the 1/2” (13mm) control valve inlet. If substituting for these components, please

consult local codes for compliance.

NOTE: This fireplace is equipped with a 3/8”(10mm) x 18” (457mm) long flexible gas connector and manual shut-off valve. The

gas line should be run to the point of connection where the shut-off valve and flexible gas line will connect.

NOTE: The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure

testing of that system at pressures in excess of ½ psi. (3.5 kPa).

NOTE: The appliance must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of the gas line at test pressures equal to or less than ½ psi (3.5 kPa).

NOTE: For high altitude installations, consult the local gas distributor or the authority having jurisdiction for proper rating

methods.

IMPORTANT: The efficiency rating of this appliance is a product of thermal efficiency rating determined under continuous operating

conditions and was determined independently of any installed system.

NATURAL GAS LP GAS

MINIMUM INLET GAS PRESSURE 5” WC (1.25 kPa) (7” WC (1.74 kPa) recommended) 11” WC (2.74 kPa) (recommended)

MAXIMUM INLET GAS PRESSURE 10.5” WC (2.62 kPa)

MANIFOLD PRESSURE (HI) 3.5 (.87 kPa)

MANIFOLD PRESSURE (LO)

ORIFICE SIZE

INPUT BTU/hr. (kW)

MINIMUM INPUT BTU/hr. (kW)

.90 (.22 kPa)

#57 & #37

39,500 (11.58 kW)

18,500 (5.42 kW)

13” WC (3.24 kPa)

10 (2.49 kPa)

2.9 (.72 kPa)

#63 & #51

39,500 (11.58 kW)

18,500 (5.42 kW)

LIGHT KIT COMPONENT INSTALLATION

(INT-200 only)

CAUTION: Disconnect all electrical power from fireplace before performing this task

NOTE: To avoid damage and prolong the life of halogen bulbs, never touch with bare hands. Always use a soft cloth when handling.

1. Install halogen bulbs (included in components packet) into lamp bases.

2. Place amber light filters into light cylinders.

PAGE 12

VENTING

IMPORTANT: Consult the local and national installation codes to assure adequate combustion and ventilation air is available.

IMPORTANT: Flame height and appearance will vary depending upon venting configuration and type of fuel used.

Venting requirements apply to both Natural and LP gas.

Refer to the vent systems manufacturer's installation manual for complete installation instructions.

Installation must conform with the venting requirements and restrictions as outlined in this manual.

Provide a means for visually checking vent connection to fireplace after fireplace is installed.

APPROVED VENTING

Simpson Dura-Vent DV-GS 5” x 8” and 4” x 6-5/8” -with reducer (horizontal and vertical terminations).

Metal Fab Direct Chimney System 5” x 8” (horizontal and vertical terminations).

ICC Direct Chimney Systems 5” x 8” (horizontal and vertical terminations).

Selkirk-Metalbestos Chimney Systems 5” x 8” and 4” x 6-5/8” -with reducer (horizontal and vertical terminations).

BDM 5” x 8” Chimney Systems (horizontal and vertical terminations).

Security 5” x 8” Chimney Systems (horizontal and vertical terminations).

Ameri-Vent 5” x 8” Chimney Systems (horizontal and vertical terminations).

ALL APPROVED VENTING

HORIZONTAL VENT SYSTEM CLEARANCES

TOP BOTTOM

1 inches (25mm) 1 inch (25mm)

SIDES

1 inch (25mm)

ALL APPROVED VENTING

VERTICAL VENT SYSTEM CLEARANCES

TOP

1 inch (25mm)

BOTTOM

1 inch (25mm)

SIDES

1 inch (25mm)

HORIZONTAL TERMINATIONS

MINIMUM: 45° elbow + 6” (152mm) horizontal + termination cap.

MAXIMUM: 45° elbow + 6ft. (1.83m) + termination cap.

HORIZONTAL TERMINATIONS

(with reducer)

NAT GAS MINIMUM: 2ft (610mm) vertical + reducer + 90° elbow + 6” (152mm) horizontal + termination cap.

NAT GAS MAXIMUM: 2ft. (610mm)vertical + reducer + 90° elbow + 12ft. (3.66m) + termination cap.

LP GAS MINIMUM: 2ft. (610mm)vertical + reducer + 90° elbow + 6” (152mm) + termination cap.

LP GAS MAXIMUM: 2ft. (610mm) vertical + reducer + 90° elbow + 2ft. (610mm) + termination cap.

LP GAS MAXIMUM: 3ft. (914mm) vertical + reducer + 90° elbow + 12ft. (3.66m) + termination cap.

IMPORTANT: Wall pass-thru required for all horizontal runs. Refer to vent manufacturer to determine which pass-thru will work best for

your application and wall thickness.

IMPORTANT: The horizontal vent heat shield must be installed when using a 45-degree elbow to horizontally position the vent system.

Exception: corner installations.

ELBOWS

The following statement applies to horizontal, vertical, or a combination of horizontal/vertical elbows:

For each additional 90° elbow used after first elbow, 3ft. (914mm) must be subtracted from maximum allowed venting. For each 45° elbow used, 1-1/2ft. (457mm) must be subtracted from maximum venting allowed.

NOTE: (2) 45° degree elbows may be used in place of (1) 90° elbow.

PAGE 13

VENTING

HORIZONTAL TERMINATIONS

NOTE: Horizontal sections require 1/4” (6mm) rise for every 12” (305mm) of travel.

NOTE: Page 16 has information on restrictor installation in conjunction with venting installation. Page 37 has information on restrictor

recommendations depending on burner flame appearance and instructions on installation after venting is completed.

CAUTION: This gas appliance must not be connected to or joined with any other chimney flue serving another appliance.

IMPORTANT: Wall pass-thru required for all horizontal runs. Refer to vent manufacturer to determine which pass-thru will work best

for your application and wall thickness.

IMPORTANT: The horizontal vent heat shield must be installed when using a 45-degree elbow to horizontally position vent system.

Exception: corner installations.

Horizontal Vent Heat Shield

45° Elbow

Minimum: 6in. (152mm)

Maximum: 6ft. (1.83m)

Termination Cap

Figure 14a

TYPICAL CORNER INSTALLATION

Pipe

90° Elbow

Termination Cap

45° Elbow

Figure 14b

PAGE 14

ALL APPROVED VENTING

VENTING

VERTICAL VENT SYSTEM CLEARANCES

TOP

1 inch (25mm)

BOTTOM

1 inch (25mm)

SIDES

1 inch (25mm)

VERTICAL TERMINATIONS

MINIMUM: 45˚ elbow + 2ft. (610mm) + termination cap.

MAXIMUM: 45˚ elbow + 50ft. (15.2m) + termination cap.

MAXIMUM (if using reducer): 45° elbow + 2ft. (610mm) + reducer + 48ft. (14.63m) + termination cap.

HORIZONTAL & VERTICAL COMBINATION TERMINATIONS

MAXIMUM: 18ft. (5.49m) horizontal + 18ft. (5.49m) vertical + cap. [36ft. (10.98m) total].

MAXIMUM (with reducer): 45° elbow + 2ft. (610mm) + reducer + 16ft. (4.88m) hor. /vert + 18ft. (5.49m) hor / vert + term. cap.

ATTENTION: IF INSTALLING WITH RIGID-TO-FLEX PIPE SYSTEMS:

More than a 30 degree bend constitutes a 45 degree elbow.

More than a 45 degree bend constitutes a 90 degree elbow.

More than a 90 degree bend is not permissible.

IMPORTANT: Wall pass-thru required for all horizontal runs. Refer to vent manufacturer to determine which pass-thru will work best for

your application and wall thickness.

IMPORTANT: The horizontal vent heat shield must be installed when using a 45-degree elbow to horizontally position the vent system.

Exception: corner installations.

ELBOWS

The following statement applies to horizontal, vertical, or a combination of horizontal/vertical elbows:

For each additional 90° elbow used after first elbow, 3ft. (914mm) must be subtracted from maximum allowed venting. For each 45° elbow used, 1-1/2ft. (457mm) must be subtracted from maximum venting allowed.

NOTE: (2) 45° degree elbows may be used in place of (1) 90° elbow.

IMPORTANT: The horizontal vent heat shield must be installed when using a 45-degree elbow to horizontally position the vent system.

Exception: corner installations

RESTRICTOR

We recommend installing a restrictor if using straight vertical terminations. It is important to remember each installation is unique and affected by various factors including venting configuration, altitude and climate. Therefore, after fireplace installation is complete, restrictor modification may be necessary.

A restrictor is included in fireplace components packet.

Please refer to page 16 for installation instructions if installing the restrictor in conjunction with venting.

Page 37 has information on restrictor recommendations depending on burner flame appearance and instructions on installation after venting is completed.

PAGE 15

VENTING

VERTICAL TERMINATIONS

CAUTION: This gas appliance must not be connected to or joined with any other chimney flue serving another appliance.

Termination Cap

Minimum: 2ft. (610mm)

Maximum: 50ft. (15.2m)

45° Elbow

Figure 16a

RESTRICTOR INSTALLATION

TO BE USED AT INSTALLER DISCRETION.

Large Restrictor

Figure 16b

Remove tab (s) to create small restrictor

Bend tabs to approx. 80 degree angles to create tension to hold itself in place when installed.

Slide restrictor into exhaust pipe on top of fireplace with tabs pointing towards you prior to attaching venting.

NOTE: Page 37 has information on restrictor recommendations depending on burner flame appearance and instructions on installation

after venting is completed.

PAGE 16

VENTING

HORIZONTAL / VERTICAL COMBINATION

Figure 17a

(15.2m)

(12.9m)

(6.1m)

2

(ft.) 0

8

6

4

18

16

14

12

10

32

30

28

26

24

22

20

42

40

38

36

34

52

50

48

46

44

0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30

Termination must be within shaded area

HORIZONTAL / VERTICAL COMBINATION:

(5.49m) 18' Vertical

(5.49m) 18' Horizontal

ATTENTION: IF INSTALLING WITH RIGID-TO-FLEX PIPE SYSTEMS:

More than a 30 degree bend constitutes a 45 degree elbow.

More than a 45 degree bend constitutes a 90 degree elbow.

More than a 90 degree elbow is not permissible.

CAUTION: This gas appliance must not be connected to or joined with any other chimney flue serving another appliance.

NOTE: Page 16 has information on restrictor installation in conjunction with venting installation.

Page 37 has information on restrictor recommendations depending on burner flame appearance and instructions on installation after venting is completed.

Horizontal sections require 1/4” (6mm) rise for every 12” (305mm) of travel.

The following statement applies to horizontal, vertical, or a combination of horizontal / vertical elbows:

For each additional elbow used after first elbow, 3ft. (914mm) must be subtracted from maximum venting allowed.

For each 45° elbow used, 1-1/2ft. (457mm) must be subtracted from maximum venting allowed.

(2) 45° degree elbows may be used in place of (1) 90° elbow.

IMPORTANT: Wall pass-thru required for all horizontal runs. Refer to vent manufacturer to determine which pass-thru will work best for

your application and wall thickness.

IMPORTANT: The horizontal vent heat shield must be installed when using a 45-degree elbow to horizontally position the vent system.

Exception: corner installations.

PAGE 17

TERMINATION VENT CAP LOCATION

This gas appliance must not be connected to a chimney serving any other appliance.

1. Terminations against vinyl siding must use a vinyl siding protector. Follow instructions included.

2. DO NOT RECESS TERMINATION KIT INTO OUTSIDE BUILDING MATERIALS - i.e.: brick, stone, siding, etc. If necessary, extend framing so that termination kit will be exposed once building materials are installed.

3. Vent termination must not be located where it will become plugged by snow or other material. The flow of combustion and ventilation air must be not obstructed.

LOCATION CLEARANCES

A. Above grade, veranda, porch, deck, balcony - 12" (305mm).

B. Operable window or door - CANADA: 12" (305mm). US: 9” (229mm).

C. Permanently closed window* - 12" (305mm) (recommended to prevent condensation on window).

D. Ventilated soffit* - 24" (610mm).

E. Unventilated soffit* - 12" (305mm).

F. Outside corner* - 3" (76mm).

G. Inside corner* - 10” (254mm).

H. Meter / Regulator: CANADA: Not to be installed above a gas meter/regulator assembly within 3ft. (914mm) horizontally from the

centerline of the regulator within a height of 15ft. (4.57m). US*.

I. Gas Service regulator vent outlet : CANADA: 3ft. (914mm). US*.

J. Non-mechanical air supply inlet to building or the combustion air inlet to any other appliance. CANADA: 12" (305mm).

US: 9” (229mm).

K. Mechanical air supply inlet. CANADA: 6ft. (1.83m) US: 3ft. (914mm) above if within 10ft. (3.05m) horizontally.

Massachusetts installations: 10ft. (3.05m).

L. Above paved side-walk or paved driveway located on public property - 7ft. (2.13m). US*

NOTE: A vent cannot be located directly above a side-walk or paved driveway that is located between two single family dwellings and

serves both dwellings.

M. Under veranda, porch, deck, or balcony (must be fully opened on a minimum of 2 sides) - 12" (305mm).

N. Between two horizontal terminations - 12" (305mm).

O. Between two vertical terminations - 12" (305mm). Terminations may be same height.

P. Above furnace exhaust or inlet - 12" (305mm).

*Clearance must be in accordance with local installation codes & the requirements of the gas supplier.

Denotes where installation not allowed

PAGE 18

VENTING

(Vertical Cap Requirements)

VENT TERMINATION CLEARANCES

Roof Pitch

Flat to 6/12

Over 6/12 to 7/12

Over 7/12 to 8/12

Over 8/12 to 9/12

Over 9/12 to 10/12

Over 10/12 to 11/12

Over 11/12 to 12/12

Over 12/12 to 14/12

Over 14/12 to 16/12

Over 16/12 to 18/12

Over 18/12 to 20/12

Over 20/12 to 21/12

H (Min.) Ft.

1.0

1.25

1.5

2.0

2.5

3.25

4.0

5.0

6.0

7.0

7.5

8.0

H (Min.) m

0.30

0.38

0.46

0.61

0.76

0.99

1.22

1.52

1.83

2.13

2.27

2.44

CAUTION: This appliance must not be connected to or joined with any chimney flue serving any other appliance.

1ft.*

(305mm)

Figure 19a

* IF VENT IS CLOSER THAN 1ft. (305mm), IT MUST TERMINATE AT

LEAST 2ft. (0.61m) HIGHER THAN ANY PORTION OF A BUILDING

WITHIN 10ft. (3.05m) OF THE VENT.

PAGE 19

#INT-500 LOG SET INSTALLATION

ATTENTION: If converting to LP (propane) gas or installing optional fan / light kit do so now before installing log set.

Follow instructions included with kits.

NOTE: Log numbers are located on the bottom of each log. Refer to following instructions and illustrations for proper placement.

CAUTION: Do not place logs directly over burner port holes.

Improper log placement may affect flame appearance and cause excessive soot to build up on logs and glass.

#1 #4

#2 #3

#4

Figure 20a

Align holes in bottom of logs #1, #2 & #3 with mounting pins on burner cover, setting down into position.

Position #4 logs (2) as shown above. Do not allow logs to block burner ports.

#5

#6 #7 #8

#9 #10

Figure 20b

Install #5 - #10 logs as shown above, aligning with notches in base logs, and in the case of log #7, aligning notch in log with burner grate.

Install #11 - #12 logs as shown below, aligning with notches in lower logs.

#11 #12

Figure 20c

Randomly place “klinkers” in this area. Do not place klinkers directly on burner ports.

Use a steel or stiff bristle brush to distribute Rock Wool Embers onto logs and burner.

PAGE 20

CONTROL BOARD REMOVAL

CAUTION: If burner and/or pilot have been burning, use appropriate protection to avoid burns or damage to personal property before

removing any components.

WARNING: DO NOT OPERATE THIS FIREPLACE WITHOUT SEALING GASKET (LOCATED UNDER CONTROL BOARD) IN PLACE.

IF GASKETING IS DAMAGED, IT MUST BE REPLACED.

1. Use remote to turn fireplace off.

2. Shut off gas supply at manual shut-off valve. Disconnect gas line flex tube from the manual shut-off valve.

3. Unplug all components from electrical outlet, disconnect all wiring harnesses attached to gas valve, disconnect pilot assembly orange and white leads from main control module.

4. INT-200 only: Disconnect light kit communication link (black and white leads) from extension module communication link (red and white leads).

5. Remove upper hood, upper louver, glass assembly, and logs.

6. Remove back burner; secured with screws, (2) at front, (2) at back.

7. INT-200 only: Remove light kit cylinders, amber light filters, and halogen bulbs. Remove screws securing light stands, lay light stands on control board.

8. Remove side refractory panels.

9. Loosen front orifice bracket screws, push orifice backwards far enough to release from venturi.

10. Remove front burner, secured with screws, (2) at front, (2) at back.

11. Remove (8) screws securing control board. Lift board up and out of firebox.

Back

Burner

Front

Burner

Back

Burner

Front

Burner

Light Stands

(INT-200 only)

PAGE 21

Figure 21a

Back Orifice

Orifice Bracket

Front Orifice

Bracket Screws

CONTROL BOARD INSTALLATION

WARNING: DO NOT OPERATE THIS FIREPLACE WITHOUT SEALING GASKET (LOCATED UNDER CONTROL BOARD) IN PLACE.

IF GASKETING IS DAMAGED, IT MUST BE REPLACED.

1. Place control board in firebox, aligning holes in board to holes in firebox bottom. MAKE SURE SEALING GASKET IS IN PLACE ON

FIREBOX BOTTOM!

Secure with screws previously removed.

2. Reinstall front burner. Align front burner orifice with front venturi, pull orifice bracket forward until orifice is seated inside venturi. Tighten orifice bracket screws. Figure 22a. Secure burner with (4) screws previously removed.

3. Reinstall side refractory panels.

4. INT-200 only: Reinstall light kit stands (secure with screws previously removed), halogen bulbs, cylinders and amber light filters.

5. Reinstall back burner assembly, making sure venturi is properly positioned over back burner orifice. Figure 22a. Secure with 4 screws previously removed.

6. Reinstall log set.

7. Reconnect gas line to manual shutoff valve.

8. Reconnect all wiring harnesses to gas valve, reconnect pilot assembly orange and white leads to main control module. Plug all components into electrical outlet.

9. INT-200 only: Reconnect light kit communication link (black and white leads) to extension module communication link (red and white).

(Black to red, white to white).

10. Reinstall glass frame assembly, upper hood and upper louver.

11. Turn gas on.

12. Verify proper log placement, operation of fireplace, and any electrical components.

Light Stands

(INT-200 only)

Back Orifice

Orifice Bracket

Front Orifice

Bracket Screws

Back

Burner

Front

Burner

Front

Back

Proper burner venturi placement over burner orifices (cut-away side view)

Figure 22a Figure 22b

PAGE 22

Back

Burner

Front

Burner

GRILL SET

INSTALLATION

1. Align hooks in upper louver to slots located in fireplace face.

Set down into position.

2. Insert upper hood flange into clips located at top of upper air passage, keeping in mind this is a fairly tight fit.

3. Partially thread (2) screws (included in components packet) into nuts at each end of lower grill. Secure to fireplace by threading screws into corresponding holes in inside flange of lower grill opening. The lower grill can now be opened and closed to access gas valve and controls.

1

2

Slide flange on upper hood into clips at top of upper air passage

REMOVAL

1. Use both hands to pull hood out of upper air passage clips.

2. Lift upper louver up and out of slots.

3. Remove screws securing lower grill at each end to remove from fireplace.

Upper hood clips

3

Thread screws into nuts grill ends and secure to lower grill opening.

Figure 23a

PAGE 23

WIRING SCHEMATICS

IMPORTANT: THIS SYSTEM REQUIRES ELECTRICITY (120 V) AND / OR BATTERIES TO OPERATE. USING BATTERY BACK UP WILL

OPERATE BURNER ONLY. FAN AND LIGHT COMPONENTS WILL NOT FUNCTION ON BATTERY BACK-UP POWER.

Included with INT-200 only

Figure 24a

THIS SYSTEM IS GROUND

TO FIREBOX CHASSIS.

PAGE 24

(WHITE)

(RED)

VALVE & PILOT ASSEMBLY COMPONENTS

PILOT

IGNITER

FLAME SENSOR

PILOT ASSEMBLY

PILOT INTERNAL SOLENOID CONNECTION

OUTLET (MANIFOLD) PRESSURE SCREW

CAP

LOW LIMIT SCREW

VALVE STEP MOTOR

STEP MOTOR WIRE HARNESS

MAIN VALVE INTERNAL SOLENOID CONNECTION

PILOT ADJUSTMENT SCREW

INLET PRESSURE SCREW

Figure 25a

GAS VALVE

PAGE 25

CONTROL MODULE COMPONENTS

LEARN BUTTON

VALVE STEP MOTOR TERMINAL

COMMUNICATION LINK TO

EXTENSION MODULE

AC ADAPTOR CONNECTION

MAIN CONTROL MODULE

CONTINUOUS PILOT ON/OFF SWITCH

REMOTE ON/OFF SWITCH

„S‟ SENSOR PILOT CONNECTION

„I‟ IGNITER PILOT CONNECTION

BACK-UP

BATTERY PACK

NON-OPERATIONAL

AC ADAPTOR

Figure 26a

COMMUNICATION LINK

TO LIGHT KIT

COMMUNICATION LINK

TO CONTROL MODULE

PAGE 26

FAN CORD PLUG-IN

EXTENSION MODULE

#INT-200 only

MANUAL ON / OFF

REMOTE CONTROL INFORMATION

THERMOSTAT MODE ICON

ROOM TEMPERATURE

FAN SPEED

Operational with INT-200

CONTINUOUS PILOT

BATTERY LIFE ICON

SET TEMPERATURE

(visible only in THERMO MODE)

LIGHT LEVEL

Operational with INT-200

CHILD PROOF ICON

FLAME HEIGHT

Figure 27a

PAGE 27

IPI INFORMATION

ELECTRICAL WARNING AND INFORMATION:

Electrical wiring must be installed by a licensed electrician.

Do NOT wire 120V to wall switch.

Uninterrupted or continuous power is required at all times in IPI systems EXCEPT when using battery back-up.

Incorrect wiring will override IPI safety lockout and may cause an explosion.

Disconnect 120V before servicing

A duplex receptacle and box cover are supplied in fireplace components packet to be used when hardwiring to electrical box located under firebox on right side of fireplace. Ensure duplex box cover is installed with flange to top.

ATTENTION: THIS SYSTEM GOES THROUGH A CALIBRATION MODE WHEN SWITCHING FROM ON TO THERMO TO

OFF MODES, CREATING A HUMMING SOUND WHICH IS A NORMAL PART OF OPERATION.

CONTINUOUS PILOT

(FOR VERY COLD CONDITIONS)

The IPI gas control system has the option of a continuous (standing) pilot feature. This allows you to change from a spark-to-pilot system to a standing pilot system during cold weather conditions. By having the pilot on continuously, the firebox will remain warm and a draft is established in the vent, allowing the main burner to turn on with less air-flow disruption.

When continuous pilot mode is activated and fireplace is turned ON, the pilot will spark and light. When fireplace is turned OFF, the pilot will remain lit when main burner has been turned OFF.

This pilot feature can be activated or de-activated by the hand held remote control transmitter. Instructions on following page.

OPERATION USING BATTERY POWER

This fireplace has an optional battery operation if electrical power is lost. Position battery pack with four “AA” size batteries installed

between valve and front of fireplace. This is the coolest location under firebox, ensuring longer battery life.

NOTE: When operating fireplace in this capacity, the only function available is flame modulation.

MATCHING SECURITY CODES

Before matching security codes make sure 120V AC is connected and powered to fireplace, and hand held remote control is installed with (2) AA batteries.

It may be necessary to program main control module to LEARN the security code of the hand held remote control upon initial use, if batteries are replaced, or if a replacement remote control is purchased from your dealer.

1. When matching security codes, be sure slide button on main control module is in REMOTE; the code will not “LEARN” if slide is in OFF.

2. Program main control module to LEARN a new security code by pushing in

LEARN button on main control module for 2 seconds, then releasing. (You should then hear a single „beep‟ letting you know module is ready to learn a new code).

3. Press MODE button on hand held remote control (you should hear four

„beeps‟ in rapid succession in main control module, indicating remote control‟s code has been programmed into the main control module). When an existing main control module is introduced to a new hand held remote control, the new security code will overwrite the old one.

If it ever becomes necessary to clear the memory from the hand held remote control, simply push and hold the LEARN button for 10 seconds (you should hear three long beeps in succession). You may now follow steps outlined above to „RE-LEARN‟ security codes.

PAGE 28

LEARN BUTTON

Figure 28a

SLIDE TO REMOTE POSITION

REMOTE CONTROL OPERATION

INITIAL SET-UP:

Plug Extension Module and AC Adaptor into receptacles.

Install (4) AAA batteries into battery compartment of Backup Battery Pack, making sure batteries are installed in proper direction.

Position between valve and front of stove. A Velcro strip has been attached to help secure in place.

The Hand Held Remote operates on (2) 1.5V AAA batteries. We recommend always using ALKALINE batteries to extend battery life and improve operational performance.

NOTE: This system is sent to you set up for Natural Gas and

temperature units readable in Fahrenheit.

This system allows for gas type conversion and temperature unit conversion by following the setup procedure outlined below.

GAS TYPE CONVERSION:

Press and hold Learn Button on Main Control Module for 20 seconds. A beep will be heard letting you know the procedure has been completed.

If converting from NAT to LP gas: (1) one second long beep

If converting from LP to Nat gas: (3) three second long beep

Continue with gas type conversion by following instructions included with gas conversion kit.

CELSIUS/FAHRENHEIT CONVERSION:

Press UP and DOWN keys simultaneously to choose Celsius or Fahrenheit.

IMPORTANT SAFETY FEATURE:

This system has a maximum room temperature limit of 95° F (35° C) in both manual and thermostat modes. When room temperature is at or above this point the system will shut down and the hand held remote control will read OFF. If you turn the system ON when room temperature is still at or above this temperature, the system will again shutdown after 2 minutes when room temperature is recalculated.

CONTINUOUS PILOT FEATURE:

Activation of this optional feature is accomplished by pressing the

PILOT button once. The continuous pilot icon will appear on the

LCD screen. Pressing PILOT button again will de-activate this feature.

This feature can also be activated via CONTINUOUS PILOT switch on

Main Control Module.

Figure 29a

CHILDPROOF FEATURE:

Activation of this optional feature is accomplished by pushing SET & UP buttons simultaneously for 5 seconds. The childproof icon will appear on the screen. When a transmitter button is pressed the icon will flash on screen, but no signal will be transmitted. Pressing and holding these same two buttons again for more than 5 seconds will de-activate this function.

This feature controls only manual functions of the hand held remote, automatic functions (thermostat mode) will not be effected.

Figure 29b

PAGE 29

REMOTE RECEIVER INFORMATION cont.

MANUAL MODE:

This remote can be manually or thermostatically operated.

Press MODE button for manual ON. The flame icon will appear on the LCD screen. Press MODE button again to put the control into THERMO mode.

Pressing MODE again will turn fireplace OFF.

NOTE: The MODE button operates in a series that will cycle from ON

to THERMO to OFF.

Figure 30a

FAN MODE:

Operational with INT-200

This remote will operate the fan, allowing for (6) different speed levels. When the FAN button is pressed, FAN level setting will flash on the LCD screen.

Press UP or DOWN buttons to select desired fan speed level. If no adjustment is made within 7 seconds, the control will exit function setting mode and

LCD display will return to normal view.

NOTE: Delayed ON/OFF - The fan will not turn on until fireplace

has been burning for 5 minutes and will not turn off for 12

minutes after fireplace has been turned off.

EXCEPTION: If fireplace is turned back on during 12 minute off-delay time

frame, the fan will remain on.

This applies to MANUAL and THERMO modes.

Figure 30b

LIGHT MODE:

Operational with INT-200

This remote will operate the lights, allowing for (6) different light levels.

When LIGHT button is pressed, LIGHT level setting will flash on the LCD screen. Press UP or DOWN buttons to select desired light level. If no adjustment is made within 7 seconds, the control will exit function setting mode and

LCD display will return to normal view.

NOTE: There is a 3 second delay before light level setting is achieved.

NOTE: Light operations are completely independent from flame and fan operations.

Figure 30c

FLAME MODE:

This remote will operate the flame, allowing for (6) different flame height levels. When MAIN FLAME button is pressed, FLAME level setting will flash on the LCD screen. Press UP or DOWN buttons to select desired flame level. If no adjustment is made within 7 seconds, the control will exit function setting mode and LCD display will return to normal view.

NOTE: The fireplace will initially light at the highest level. After 5

seconds the flame will adjust to last chosen level before

fireplace was turned OFF.

This applies to MANUAL and THERMO modes.

Figure 30d

PAGE 30

REMOTE RECEIVER INFORMATION cont.

THERMO (THERMOSTAT) MODE:

This remote feature allows you to thermostatically control the fireplace when hand held remote is set to

THERMO mode.

Set Temperature Range: 45˚F (7˚C) to 90˚F (32˚C).

Set remote to THERMO mode by pressing MODE button. The smaller SET window of numbers appears on the LCD screen. The first SET number will read 45˚F. Press UP button to desired set room temperature.

Within 5 seconds fireplace will operate to that Set Temperature. The FLAME, ON and THERMO icons will appear on the LCD screen. By pressing UP or DOWN buttons a new set temperature may be attained.

SET Temperature will only appear when THERMOSTAT MODE is activated, but is implemented in all MODES with the exception of MANUAL MODE.

NOTE: The flame height can adjust up to (6) different height levels according to amount of heat required. This range however is dictated by the Flame Level setting (see previous page).

When desired temperature is met, the fireplace will shut off until more heat is required.

To exit THERMO mode press the MODE button. This also shuts fireplace OFF.

IMPORTANT: When in THERMO mode the fireplace will not turn on until room temperature falls

below SET TEMPERATURE.

Figure 31a

SYSTEM OPERATION WITHOUT HAND HELD REMOTE:

This system is designed to operate with the hand held remote or a thermostat, but in the unlikely event that it is required to be operated without the hand held remote or a thermostat, follow this simple procedure.

Slide REMOTE /OFF switch on main control module to OFF. The fireplace can now be lit and shut off by use of the ON/OFF rocker switch.

NOTE: When operating fireplace in this capacity, the only function available is burner operation on HI.

REMOTE / OFF

Figure 31b

PAGE 31

LIGHTING AND SHUTDOWN

FOR YOUR SAFETY - READ BEFORE OPERATING

WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT, CAUSING

PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.

1. This appliance is equipped with an ignition device which automatically lights the pilot. DO NOT try to light the pilot by hand.

2. BEFORE LIGHTING, smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS:

Do not try to light any appliance.

Do not touch any electrical switches; do not use the phone in your building.

Immediately call your gas supplier from a neighbor‟s phone. Follow the gas supplier‟s instructions.

If you cannot reach your gas supplier, call the fire department.

3. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and

to replace any part of the control system and any gas control which has been under water.

DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR

ANY OTHER APPLIANCE.

WARNING: CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERATURES

AND SHOULD STAY AWAY TO AVOID BURNS OR CLOTHING IGNITION. YOUNG CHILDREN SHOULD BE

CAREFULLY SUPERVISED WHEN THEY ARE IN THE SAME ROOM AS THE APPLIANCE. CLOTHING OR

OTHER FLAMMABLE MATERIAL MUST NOT BE PLACED ON OR NEAR THE APPLIANCE.

NOTE: A PAINT SMELL WILL OCCUR DURING THE FIRST FEW HOURS OF BURNING. IT IS RECOMMENDED TO

LEAVE THE FAN OFF DURING THIS PERIOD TO HELP SPEED THE PAINT CURING PROCESS.

NOTE: THIS FIREPLACE MAY PRODUCE NOISES OF VARYING DEGREE AS IT HEATS AND COOLS DUE TO METAL

EXPANSION AND CONTRACTION. THIS IS NORMAL AND DOES NOT AFFECT THE PERFORMANCE OR

LONGEVITY OF THE FIREPLACE.

DUE TO HIGH SURFACE TEMPERATURES, KEEP CHILDREN, CLOTHING AND FURNITURE AWAY.

This appliance needs fresh air for safe operation and must be installed so there are provisions for adequate combustion and ventilation air.

PAGE 32

LIGHTING AND SHUTDOWN (cont.)

OPERATING INSTRUCTIONS

STOP! Read safety information on previous page and front

cover of this manual before continuing.

1. Turn off all electric power to the appliance.

ATTENTION: This appliance is equipped with an ignition device

which automatically lights the pilot. DO NOT try

to light the pilot by hand.

2. Press hand held remote MODE button to OFF.

3. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow „WHAT TO

DO IF YOU SMELL GAS‟ below. If you don‟t smell gas, go to next step.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use the phone in your building.

Immediately call your gas supplier from a neighbor‟s phone. Follow the gas supplier‟s instructions.

If you cannot reach your gas supplier, call the fire department.

1

3 5 MINUTES

4

Power OFF

Power ON

2

OFF

5

ON

4. Turn ON all electric power to fireplace.

5. Press hand held remote MODE button to ON.

CAUTION: If fireplace will not operate, follow instructions

TO TURN GAS OFF TO APPLIANCE and call

your service technician or the gas supplier.

NOTE: When fireplace is initially lit, condensation will appear

on the glass; this is normal in all gas fireplaces and will

disappear after several minutes.

Figure 33a

TO TURN GAS OFF TO APPLIANCE

1. Press hand held remote MODE button to OFF.

2. Turn OFF all electric power to appliance if service is to be performed.

3. Open lower grill to access manual shut-off valve located under firebox. Turn manual shut-off valve to OFF.

1

OFF

3

2

Power OFF

PAGE 33

Figure 33b

PRESSURE TESTING

IMPORTANT NOTICE: Pressure check taps for manifold (outgoing) and inlet (incoming) pressure have been incorporated into

the valve. The pressure tap marked OUT measures outgoing pressure and the pressure tap marked IN

measures incoming pressure. Follow instructions below for proper testing procedures. Refer to page 12 for

proper NAT and LP manifold pressures.

NOTE: The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at pressures in excess of ½ psi. (3.5kPa).

NOTE: The appliance must be isolated from the gas supply piping system by closing its individual manual shut-off valve during

any pressure testing of the gas line at test pressures equal to or less than ½ psi (3.5 kPa).

INLET PRESSURE TEST:

1. Loosen inlet (IN) pressure tap screw (counter-clockwise).

2. Attach manometer using a 1/4” I.D. hose.

3. Light fireplace using hand held remote control. Note manometer reading.

4. Turn fireplace off using hand held remote control.

5. Disconnect hose and tighten screw (clockwise). Screw should be snug, do not over tighten.

9. Relight fireplace using hand held remote control. Reattach manometer to inlet pressure tap to verify it is completely sealed.

Manometer should read no pressure.

NOTE: If inlet pressure reading is too high or too low, contact the gas company. Only a qualified gas service technician should adjust

incoming gas pressure.

CAUTION: A LOW PRESSURE READING CAN CAUSE DELAYED IGNITION.

Outlet (Manifold) Pressure Screw

Low Limit Screw

Inlet Pressure Screw

Figure 34a

PAGE 34

ERROR CODES

IGNITION SAFETY: Protection for Ignition System

Error Code: One beep every one second.

Description of Fault: Warns users if pilot is not successfully ignited in 60 seconds.

How to Clear: Press MODE button to OFF then to ON to re-attempt ignition.

What to Check:

Ensure gas supply is turned on.

Ensure black cap leads marked PILOT from module are plugged into PILOT connection on valve body.

Verify lead from igniter on pilot assembly is connected to I terminal on main control module. (Clicking sound will also be heard).

Verify lead from flame sensor on pilot assembly is connected to S terminal on main control module. (Pilot will light but main burner will not. Pilot will extinguish after 60 seconds and error code will alarm).

Verify black ground lead is connected to tab extending from valve bracket.

SENSOR SAFETY: Protection for Flame Sensor

Error Code: Four beeps every one second.

Description of Fault: Warns users pilot flame senor detects a pilot flame already present when ignition sequence is initiated. This fault will

also occur if pilot flame senor on main control module is shorted to ground.

How to Clear: Press MODE button to OFF then to ON to re-attempt ignition.

What to Check:

Check if pilot flame is actually present when valve is turned OFF (if yes, replace valve).

Replace pilot assembly.

Replace module.

THERMAL SAFETY: Overheat Protection

Error Code: Four beeps every two seconds.

Description of Fault: Warns users that module‟s internal temperatures have exceeded 170˚ F (77˚C).

How to Clear: Module‟s internal temperatures must cool to below 160˚F (71˚C) and then press ON button.

What to Check:

Are modules located in an unapproved location. Move to cooler location.

COMMUNICATION SAFETY: Protection for Ignition System

Error Code: One beep every four seconds.

Description of Fault: Warns users the hand held remote and main control module are not communicating properly. This safety feature is

active in both manual and thermo modes. The remote control sends a communication safety signal every 15 minutes.

If the main control module does not receive this signal, it begins a 2-hour countdown. If no communication safety

signal is received at the end of this countdown, the system will enter communication safety shutdown which turns

system OFF and emits the error code.

What to Check:

Verify batteries in hand held remote control are new.

Ensure remote control is located within 20ft. (6m) of main control module.

Ensure remote control is not placed directly on top of or inside a metal enclosure as this can interfere with transmission.

PAGE 35

FINALIZING THE INSTALLATION

FLAME APPEARANCE:

Flame appearance is affected by several factors including altitude, venting configuration and fuel quality. Although the venturi settings have been factory set, adjustments may be necessary for optimal performance and visual aesthetics.

When fireplace is first lit, the flames will be blue. Flames will gradually turn yellowish-orange during first 15 minutes of operation. If flames remain blue, or become dark orange with evidence of sooting (black tips), burner tube venturis may need adjustment.

WARNING: BURNER TUBE ADJUSTABLE VENTURI POSITIONING SHOULD ONLY BE PERFORMED BY A QUALIFIED

PROFESSIONAL SERVICE TECHNICIAN.

FRONT BURNER

BACK BURNER

FACTORY SET BURNER TUBE VENTURI SETTINGS

(ADJUST AS NECESSARY FOR YOUR INSTALLATION)

NATURAL GAS

100% CLOSED

1/8” (3mm) OPEN

LP (PROPANE) GAS

5/8” (16mm) OPEN

5/8” (16mm) OPEN

VENTURI POSITION

Closed too far

Open too far

BURNER TUBE VENTURI ADJUSTMENT GUIDELINES

FLAME COLOR VENTURI ADJUSTMENT

Dark orange flame with black tips Open venturi setting slightly

Blue flames Close venturi setting slightly

NOTE If soot is present, check log positioning before adjusting burner venturi. Logs must not block burner ports.

IMPORTANT: SLIGHT ADJUSTMENTS TO BURNER VENTURI OPENING CREATE DRAMATIC RESULTS. ADJUST AT SLIGHT INCREMENTS

UNTIL DESIRED LOOK IS ACHIEVED. ALWAYS BURN FIREPLACE FOR AT LEAST 15 MINUTES AND ALLOW TIME TO COOL

BEFORE MAKING ANY FURTHER ADJUSTMENTS.

TO ADJUST VENTURIS:

WARNING: To avoid property damage or personal injury, allow fireplace time to cool before making any adjustments.

Remove back burner. Back venturi is located underneath back burner, front venturi is located above control board. Loosen venturi screws, adjust as necessary. Tighten screws. Reinstall all previously removed components, ensuring proper venturi placement over burner orifices.

Front Burner Orifice

Front Burner Venturi

Figure 36a Proper burner venturi placement over burner orifices (cut-away side view)

PAGE 36

Back Burner Venturi

Back Burner Orifice

FINALIZING THE INSTALLATION

RESTRICTOR USAGE:

Turn fireplace on and allow to burn for 15 minutes.

If flames indicate there is excessive draft (flickering, short flames), a restrictor may be necessary.

If flames indicate insufficient draft (lifting or ghosting flames), a previously installed restrictor may need to be modified or removed.

WARNING: TO AVOID PROPERTY DAMAGE OR PERSONAL INJURY, ALLOW FIREPLACE AMPLE TIME TO COOL BEFORE MAKING ANY

ADJUSTMENTS AND / OR INSTALLATIONS.

FLAME APPEARANCE

RESTRICTOR TROUBLESHOOTING

DRAFT PROBLEM RESTRICTOR SOLUTION

Short, flickering

Lifting or ghosting*

Excessive draft - not enough restriction

Insufficient draft - too much restriction

Add restrictor

Remove inner ring (s) on restrictor or remove restrictor

* Improper venting installation may cause flames to lift or “ghost” - a dangerous situation. Inspect flames after installation to ensure proper performance. If determined that venting is correct, and the restrictor has been removed, yet flames are still lifting or ghosting, shut off gas supply to fireplace and call a qualified service technician.

RESTRICTOR INSTALLATION / MODIFICATION (after termination completion) :

If determined that a restrictor is needed or restrictor modification is required after termination is installed, access can be reached through fireplace baffle. Remove logs, back burner, upper refractory clips and refractory.

1. Remove (3) screws securing baffle. Remove baffle to expose venting.

2. Depending on your specific needs, determined by the chart above along with other factors, make necessary modifications.

3. If installation of a restrictor (included in fireplace components packet) is necessary, bend tabs on restrictor to approx. 80 degree angles to create tension when inserted into exhaust pipe on fireplace. Insert restrictor into 5” exhaust pipe with tabs pointing towards you.

4. If modification is necessary, remove restrictor by pulling it down and out of 5” exhaust pipe.

5. Reinstall baffle by resting baffle front above flange along inside top of firebox opening. Tip baffle back against rear firebox wall.

Secure with (3) screws previously removed.

6. Reinstall refractory panels, back burner assembly (ensure venturi is properly positioned over burner orifice), and log set.

7. Attach glass frame assembly and light fireplace. Wait 15 minutes before determining if any further modifications are necessary.

Flange Baffle Remove tab (s) to create small restrictor

5” (122mm) exhaust

Small

Figure 37a

(3) screws securing baffle

Bend tabs to approx. 80 degree angles to create tension to hold itself in place when installed .

PAGE 37

Slide restrictor into exhaust pipe at top of fireplace with tabs pointing towards you.

MAINTENANCE

The appliance is required to be inspected at least once a year by a professional service person.

The compartment below firebox (behind lower grill) must be cleaned at least once a year, more frequent cleaning may be required due to excessive lint from carpeting, bedding materials, or other fibrous materials. Use a vacuum to clean all components at least once a year.

NOTE: INSTALLATION AND REPAIR SHOULD BE DONE ONLY BY QUALIFIED SERVICE PERSON. THE APPLIANCE SHOULD BE

INSPECTED BEFORE USE AND ANNUALLY BY A QUALIFIED SERVICE PERSON. MORE FREQUENT CLEANING MAY BE

REQUIRED DUE TO EXCESSIVE LINT FROM CARPETING, BEDDING MATERIALS, ETC. IT IS IMPERATIVE THAT CONTROL

COMPARTMENTS, BURNERS AND CIRCULATION AIR PASSAGEWAYS OF THE APPLIANCE BE VACUUMED ONCE A YEAR .

CONTROL BOARD SYSTEM

Annual cleaning of burner system is required. Vacuum all components thoroughly.

The burner assemblies may be removed for easier access. Refer to pages 21 in this installation manual for complete instruction on removing & reinstalling burner assemblies.

Visually check for blocked port holes, especially near the pilot. Blocked port holes may cause delayed ignition.

Reinstall burner assemblies following instructions on page 21-22 of this installation manual.

Visually check pilot light and burners when in operation. Flames should be steady, not lifting or floating.

Pilot Assembly

Figure 38a

Burner Orifice Burner Ports

FAN

The fan should be disconnected from electrical current, and cleaned (vacuumed) every six months. The bearings are sealed and require no oiling.

VENT SYSTEM

Annual examination of venting system by a qualified agency is required.

IF VENT-AIR INTAKE SYSTEM IS DISASSEMBLED FOR ANY REASON, RE-INSTALL PER INSTRUCTIONS PROVIDED WITH INITIAL

INSTALLATION.

The flow of combustion and ventilation air must not be obstructed.

GLASS CLEANING & REPLACEMENT

Clean glass only when cool and only with non-abrasive cleansers.

WARNING: DO NOT OPERATE APPLIANCE WITH THE GLASS/FRAME ASSEMBLY REMOVED, CRACKED OR BROKEN. REPLACEMENT OF THE

GLASS SHOULD ONLY BE PERFORMED BY A LICENSED OR QUALIFIED SERVICE PERSON.

Use protective gloves to handle any broken or damaged glass assembly components.

The glass assembly, part #INT-057T, shall only be replaced as a complete unit, as supplied by Hussong Mfg. Co., Inc.

Replacement of glass & frame assembly, part #INT-057T, must only be performed by a licensed or qualified service person.

DO NOT SUBSTITUTE MATERIALS.

Do not strike or slam glass door assembly.

IMPORTANT: ANY SAFETY SCREEN OR GUARD REMOVED FOR SERVICING MUST BE REPLACED PRIOR TO OPERATING THE APPLIANCE.

CAUTION: LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING CONTROLS. WIRING ERRORS CAN CAUSE IMPROPER AND

DANGEROUS OPERATION. VERIFY PROPER OPERATION AFTER SERVICING.

CAUTION: KEEP APPLIANCE AREA CLEAR OF COMBUSTIBLE MATERIALS, SUCH AS GASOLINE AND OTHER FLAMMABLE VAPORS AND LIQUIDS.

PAGE 38

TROUBLESHOOTING

MAIN CONTROL MODULE WILL NOT LEARN TRANSMITTER

Ensure REMOTE/OFF switch on side of main control module is set to REMOTE.

Make sure batteries in both the hand held remote and backup battery pack are installed in the proper direction and are not drained.

Verify hand held remote indicates a signal is being sent. The LCD display should indicate ON or OFF depending on which button is being pressed. The LED indicator should illuminate on wall transmitters and on/off transmitters. Buttons should be pressed and held for

1 to 2 seconds to ensure a complete signal is sent.

Ensure 4-pin lead-set is securely connected from battery pack to main control module‟s AUX connection. If the A/C adapter is used, check that leads from adapter are securely connected to POWER terminals on main control module.

Press and hold LEARN button on main control module for approximately 10 seconds to clear memory (you should hear a series of beeps from the receiver), immediately press either the ON or OFF button on hand held remote (you should hear a series of beeps indicating the transmitter code has been learned).

PILOT WILL NOT LIGHT / STAY LIT

Verify gas supply is turned on.

Verify main control module is receiving signal from hand held remote by listening for a beep from receiver when ON is pressed on hand held remote. If you do not hear a beep, ensure main control module has learned the hand held remote. (See above).

Ensure black lead from pilot assembly igniter is securely connected to terminal labeled “I” and red lead from flame rectification sensor is securely connected terminal labeled “S” on main control module.

Ensure black cap leads marked PILOT from main control module are securely connected to terminals labeled PILOT on valve body.

Ensure black GROUND wire is securely connected to tab located next to ON/OFF toggle switch. A proper ground is essential to spark igniter operation.

Make sure pilot flame is in contact with flame rectification sensor on pilot assembly. This valve is equipped with a pilot flame adjustment screw. If pilot flame is too small it will not contact flame rectification sensor and will not complete the safety circuit.

Check continuity of pilot on valve. Remove wire connector. If there is no continuity on pin terminals, replace valve.

PILOT FLAME ALWAYS ON / WILL NOT EXTINGUISH

Ensure continuous pilot icon is not present in LCD screen. If icon is present, press PILOT button. This will de-activate the continuous pilot feature and the icon will disappear from LCD screen.

PILOT BURNING BUT IGNITER CONTINUES TO SPARK

Check that flame sensor is fully engulfed by pilot flame. If needed, adjust pilot.

Check end-to-end continuity of sensor. If sensor has continuity, replace module.

PAGE 39

TROUBLESHOOTING

MAIN FLAME WILL NOT LIGHT

Verify gas supply is turned on.

Ensure pilot flame will ignite. If not, see pilot flame troubleshooting on previous page.

Make sure white cap leads marked MAIN from module are securely connected to terminals marked MAIN on valve body.

Make certain pilot flame is in contact with flame rectification sensor on pilot assembly. This valve is equipped with a pilot flame adjustment screw. If pilot flame is too small it will not contact flame rectification sensor and will not complete the safety circuit.

Ensure pilot flame is properly located to ignite main flame.

Does hand held remote show CP in the display? If yes, childproof is on. De-activate by pushing PROG/TIME & UP keys at same time for more than 5 seconds.

Check continuity of main burner coil on gas valve. Remove wire connector. If there is no continuity on pin terminals, replace valve.

FLAME HEIGHT ADJUSTMENT NOT WORKING / WORKS BACKWARDS

Ensure “+” (white dotted wire) and “—” (black wire) leads from battery pack or module are securely connected to “+” (white dotted wire) and “—” (black wire) leads from main control module (“+” to “+”, “—” to “—”).

Check functionality with all transmitters to determine if there is an issue with the main control system or an individual transmitter. If the issue is with an individual transmitter, make sure batteries in hand held remote and backup battery pack are installed properly and are not drained.

ROOM TEMP. DISPLAYED ON HANDHELD REMOTE NOT CORRECT

Ensure transmitter was not recently stored in a different location (air-conditioned, heated) from that in which the hand held remote was tested. It may take up to 3 hours for the temperature inside a packaged transmitter, and several minutes for an unpackaged transmitter to equalize with room temperature.

FIREPLACE WILL NOT RESPOND IN “THERMO” MODE

Ensure hand held remote is within 20ft. (6.096m) operational range.

Make sure an ON or OFF command was not last sent from another transmitter. These commands will override thermal commands from the handheld remote control. To return system to THERMO mode, press either ON or OFF on hand held remote, then press

MODE button to put system in THERMO mode. Press and hold SET button to change set temperature.

Verify set temperature on hand held remote is at least 2˚F (1˚C) above or below room temperature. The system will not react to temperatures within 2˚F (1˚C) of set temperature.

PAGE 40

CONVERSION KIT INSTRUCTIONS

#OCK-A3757N-I-INT-PSE NAT GAS CONVERSION KIT / #OCK-A5163L-I-INT-PSE LP GAS CONVERSION KIT

WARNING:

This conversion kit shall be installed by a qualified service agency in accordance with the manufacturers instructions and a l l applicable codes and requirements of the authority having jurisdiction. If the information in these instructions is not followed exactly, a fire, explosio n o r pro ductio n o f ca rbon mo no xide ma y result, ca u sing pro perty da ma g e, pers o na l injury o r lo ss of lif e. The qualified service agency is responsible for proper installation of this kit. The installation is not proper and complete until operation of the converted appliance is checked as specified in the instructions supplied with the kit. Refer to appliance owner‟s manual or product data plate for proper inlet and manifold pressure adjustments and orifice sizing.

Kit includes: (1) Gas Conversion Label (1) Pilot Orifice: NAT #.018 / LP #.012

(2) Burner Orifices: NAT #37 & #57 / LP #51 & #63 (1) Low Limit Screw: NAT #42 / LP #54

(1) Gas Label

CAUTION: THE GAS SUPPLY SHALL BE SHUT OFF PRIOR TO DISCONNECTING THE ELECTRICAL POWER, BEFORE PROCEEDING

WITH THE CONVERSION.

WARNING: SHUT OFF GAS SUPPLY AND ELECTRIC POWER TO FIREPLACE. SHUT OFF GAS SUPPLY BEFORE DISCONNECTING

ELECTRIC POWER.

PREPARE THE FIREPLACE:

1. Remove upper hood, upper louver, glass assembly*.

2. Remove logs*.

3. Remove back burner assembly from fireplace*.

4. Loosen screws securing front orifice bracket, pull orifice backwards out of front venturi.

Lower fitting

Upper fitting

Pilot bracket

REPLACE BURNER ORIFICES:

Remove existing orifice caps and replace with orifice caps included with kit, placing orifice with small hole at the front of fireplace and orifice with large hole at the back. Tighten caps securely.

CONVERT PILOT ASSEMBLY:

1. Remove (2) screws securing pilot assembly to pilot bracket. Place 7/16” wrench on upper fitting and 1/2” wrench onto lower fitting, turn pilot hood nut counter-clockwise to remove pilot hood.

2. Remove pilot orifice located inside lower fitting and replace with one included with kit.

3. Re-attach pilot hood. Tighten with wrenches, making sure pilot hood is positioned as shown in Figure 41c. Final alignment of sensor and hood outlet is critical for proper ignition.

4. Attach pilot assembly to pilot bracket with screws previously removed.

Figure 41a

Pilot orifice:

Remove existing, replace with one included with kit

Figure 41b

Sensor Align

Figure 41c

Hood outlet GAS TYPE CONVERSION:

Press and hold Learn Button on Main Control Module for 20 seconds. A beep will be heard letting you know the procedure has been completed.

If converting from NAT to LP gas: one (1) second long beep

If converting from LP to Nat gas: three (3) second long beep

PRESSURE REGULATOR CAP

CONVERT GAS CONTROL VALVE:

1. Remove cap covering the pressure regulator.

2. Press down on pressure regulator tube and rotate 90˚. The shaft will pop out and point to chosen gas type. Re-attach cap.

3. Remove existing low limit screw (located above valve motor, see page 34).

Replace with one included with kit.

PAGE 41

NAT. SETTING

Figure 41d

L.P. SETTING

CONVERSION KIT INSTRUCTIONS

COMPLETE THE CONVERSION:

1. Adjust burner venturi settings by loosening screws, adjusting caps and retightening screws.

Note: Venturi may need further adjustment, depending on your venting configuration.

CORRECT SETTINGS: NAT. : Front venturi - closed / Back venturi - 1/8” (3mm)

L.P. : Both venturis - 5/8” (16mm) open

2. Pull front orifice bracket forward until orifice is properly seated in front venturi. Tighten screws*. Figure 42a.

3. Re-install back burner assembly into fireplace, checking to ensure burner venturi is properly seated over burner orifices*. Figure 42a.

4. Re-install logs*.

5. Turn on gas and electrical supplies.

6. Light fireplace*. Check for leaks at all connections with a gas leak detector, whether field or factory made, .

7. Test inlet pressure*.

8. Visually check pilot flame. Flame should envelope top of flame sensor and extend onto burner far enough for proper ignition.

To Adjust Pilot: Turn pilot adjustment screw clockwise to decrease or counter-clockwise to increase pilot flame.

9. Turn fireplace off.

10. Affix gas type sticker to existing label.

11. Reinstall glass frame assembly, upper louver and upper hood*.

12. Complete and affix Gas Conversion label behind lower grill.

*REFER TO CORRESPONDING PAGES IN THIS INSTALLATION MANUAL IF NECESSARY.

Front

Back

Figure 42a

Proper burner venturi placement over burner orifices (cut-away side view)

Figure 42b

GAS CONVERSION LABEL (included with conversion kit)

PAGE 42

#INT-060 OPTIONAL UPGRADE KIT FOR INT-100

INSTALLATION OF THIS KIT SHOULD BE DONE ONLY BY A QUALIFIED INSTALLER

WARNING: Disconnect any electrical components from their power source prior to performing this task!

This kit includes: (1) Rear Light Kit (1) Extension / Fan Module Kit

w/ 4-pin wire harness

(1) Fan Kit- (2) 75 CFM

w/ (4) nuts

WARNING: MAKE SURE HOUSEHOLD BREAKER IS SHUT OFF PRIOR TO WORKING ON ANY ELECTRICAL LINES.

WARNING: THIS APPLIANCE IS EQUIPPED WITH A THREE-PRONG (GROUNDING) PLUG FOR PROTECTION AGAINST

SHOCK HAZARD AND SHOULD BE PLUGGED DIRECTLY INTO A PROPERLY GROUNDED THREE-PRONG

RECEPTACLE.

NOTE: This appliance must be electrically grounded and connected in accordance with local codes, or in the absence of local codes, with the

National Electrical Code, ANSI/NFPA 70 Current Edition, or the Canadian electrical Code CSA C22.1.

The following components must be removed from fireplace before installing this kit. Upper grill, upper hood, lower grill, glass frame assembly, log set and back burner assembly. Refer to corresponding pages in this installation manual for assistance if necessary.

NOTE: PLEASE REFER TO WIRING SCHEMATIC ON FOLLOWING PAGE FOR ASSISTANCE.

1. Disconnect all wiring harnesses from gas valve.

2. Remove control module housing assembly from compartment under firebox.

3. Insert fans through right side of lower grill opening, push to back of fireplace. Align mounting slots in fan brackets with mounting studs.

Secure with nuts.

4. Locate extension/fan module kit. Insert one end of 4-pin wiring harness into

4-pin receptacle marked COMM on extension/fan module.

5. Install extension/fan module into housing, making sure power cord is facing the back side. Velcro strips have been attached to help secure in place.

6. Insert other end of 4-pin extension/fan module wiring harness into

4-pin receptacle on main control module marked COMM.

7. Plug fan cord into receptacle on extension / fan module marked FAN.

8. Locate and remove screws at back corners of firebox (2 ea. side). Align light stands over these holes, positioning base flanges towards center of fireplace and light brackets toward outer firebox. Secure with screws previously removed.

9. Locate and remove triangular shaped plate from back left side of control board. Reinstall screws. Install rubber grommet included with light kit into large remaining hole.

10. Feed light stand wires through grommet, pulling under firebox to front left side. Connect white wire on extension/fan module to white wire on light kit, repeating with red/black wires.

11. Silicone around grommet and wires to create an airtight seal.

12. Install halogen bulbs into receptacles. Check that bulbs are working by plugging power cord into outlet. Unplug before continuing.

PAGE 43

Control module housing assembly

4-pin wiring harness

Extension/Fan module

Figure 43a

Light stand mounting holes

Triangular shaped plate

Light stand

#INT-060 OPTIONAL UPGRADE KIT FOR INT-100

13. Install light cylinders (with flared end up) over light stands until resting on light stand tabs.

14. Insert (1) amber colored light filter into each light cylinder.

15. Reinstall back burner assembly, ensuring venturi is properly seated over burner orifice. Refer to instructions on page 22.

16. Reattach all previously removed wiring harnesses to gas valve.

17. Plug extension/fan module and AC adaptor into electrical outlet located under fireplace.

18. Reinstall control module housing assembly into fireplace.

19. Reinstall log set, glass valance, upper hood, upper grill and lower grill, following instructions as outlined in this fireplace installation manual.

20. Restore electrical power to fireplace. Verify proper operation of all components.

Figure 44a

THIS CONTROL SYSTEM IS

GROUND TO FIREBOX CHASSIS

PAGE 44

(WHITE)

(BLACK)

REPLACEMENT PARTS LIST

Replacement parts are available through your local dealer. Contact them for availability and pricing.

CONTROL BOARD SYSTEM AND PARTS

INT-600-IPI

INT-601-IPI

700-400-06

INT IPI Board - Nat Gas

INT IPI Board - LP Gas

Main Control Module

700-404-INT IPI Valve - Natural Gas

700-404-INT-1 IPI Valve - LP Gas

700-201 Pilot Assembly - Natural Gas

700-201-1 Pilot Assembly - LP Gas

700-800

700-500

700-120

700-401

700-750

INT-208

8-PIN Primary Wire Harness: Primary Wire Harness

5-PIN Wire Harness: Main Module to Valve Step Motor

Extension Module (INT-200 only)

4-PIN Wire Harness: Control Module to Extension Module

7.5 Volt Adaptor

IPI Remote Control

700-203

700-213B

700-226F

700-257

700-237

700-263

700-251

Manual Shut-off Valve

18” Flexible Gas Line-Black

Flexible Gas Line-Valve to Burner Connection

Natural Gas Orifice #57 - front burner

Natural Gas Orifice #37 - back burner

LP Gas Orifice #63 - front burner

LP Gas Orifice #51 - back burner

OCK-A3757N-I-INT-PSE Natural Gas Conversion Kit

OCK-A5163L-I-INT-PSE LP Gas Conversion Kit

INT-135

700-342

Burner / Log Grate Assembly

NAT. Low Limit Screw #42

700-354

700-752

LP Low Limit Screw #54

Pilot Igniter (with wire)

700-094-P

700-095-P

700-751

NAT. Gas Pilot Orifice (PSE)

LP Gas Pilot Orifice (PSE)

Battery Back-up with (4) AA Batteries

700-753

700-403

Pilot Flame Sensor (with wire)

Step Motor

TRF-200

TRF-200A

TRF-201

TRF-200L

GRILL REPLACEMENT

Upper Hood

Upper Low Profile Hood (may be used behind full door faces)

Lower Grill

Upper Hood Louver

INT-G900

REFRACTORY PANELS

(4 pc.) Refractory Panel Set

INT-G900LS Left Side Refractory Panel

INT-G900RS Right Side Refractory Panel

INT-G902

INT-900B

Top Refractory Panel

Back Refractory Panel

COMBUSTIBLE MATERIAL BACKER BOARD

MTK-FPS FirePro Standoff

INT-500

INT-1

INT-2

INT-3

INT-4

INT-5

INT-6

INT-7

INT-8

INT-9

INT-10

INT-11

INT-12

900-KLK

900-REMB

LOG SET

Log Set

#1 Log

#2 Log

#3 Log

#4 Log

#5 Log

#6 Log

#7 Log

#8 Log

#9 Log

#10 Log

#11 Log

#12 Log

Klinkers

Rock Wool Embers

INT-005

900-006

INT-057T

GLASS & GLASS GASKET

Replacement Valance

1-1/8” Glass Gasket w/ Adhesive

Valance with 26” x 35” glass

INT-028

INT-RLK

600-676

600-678

FAN ASSEMBLIES (INT-200 only)

Fan Kit (INT-200 only)

LIGHT KIT (INT-200 only)

Light Kit

35W 130V Halogen Bulb

Amber Disk

*Consult your dealer for information on optional accessories available for this fireplace.

This appliance tested & certified by:

OMNI - Test Laboratories, Inc.

13327 NE Airport Way

Portland, Oregon 97230

Models #INT-100 / #INT-200

PAGE 45

Manufactured by:

Hussong Mfg. Co., Inc.

204 Industrial Park Drive

Lakefield, Minnesota 56150

507-662-6641

LIMITED WARRANTY

Effective July 01, 2011

LIMITED 10 YEAR WARRANTY

This Limited 10 Year Warranty will not become effective until the Warranty Registration form has been completed and mailed to Hussong Manufacturing Co., Inc., P.O. Box 577, Lakefield,

MN. 56150. This registration form must be received within 30 day of installation. Failure to do so may result in delayed warranty coverage and submission of proof of purchase will be required.

Hu sson g Manu factu rin g Co ., In c. warran ties to th e original purchaser of this Ambiance Fireplace, that it is free of defects in materials and workmanship at the time of manufacture.

Subject to the following conditions and requirements,

Hussong Manufacturing Co., Inc. extends the following limited warranty under normal use and service, with respect to the Ambiance line of gas burning fireplaces.

YEAR 1: Subject to the conditions and requirements listed below, within the first year from date of purchase, Hussong

Manufacturing Co., Inc. shall, at its discretion, replace or repair any such defect in material or workmanship, at Hussong

Manufacturing Co., Inc.‟s expense, including reasonable labor costs to repair or replace the defective component, if a factory pre-authorization is given for the repair.

YEARS 2-10: Subject to the conditions and requirements listed below, beginning with the first day of the second year and c o n t i n u i n g t h r o u g h t h e t e n t h y e a r , H u s s o n g

Manufacturing Co., Inc., will at its discretion, provide repair or replacement parts at current list prices for any defect in material or workmanship of components, including optional components and accessories (if available). Hussong Manufacturing Co., Inc. shall not be responsible for any installation, labor transportation or other indirect costs.

To make a claim under this warranty, the purchaser must first contact the dealer/installer from whom the fireplace was purchased.

This limited warranty will be void if the fireplace is not installed b y a q u a l i f i e d i n s t a l l e r a n d a c c o r d i n g t o t h e installation instructions. Use of unauthorized components will make this warranty null and void.

This Limited Warranty also is void if the fireplace is not o p er a t ed , a t a l l t i me s , a c c o rd in g to th e o p e r at in g instructions furnished.

This warran ty is limited to defects in material and workmanship. It does not apply to any product that has been s u b j e c t t o n e g l i g e n c e , m i s a p p l i c a t i o n , i m p r o p e r installation. Remote control warranties are covered by the remote control manufacturer and are excluded from this Limited

Warranty.

No p erson is au tho rized to exten d th e time o f th is warranty or accept on Hussong Manufacturing Co., Inc.‟s behalf any additional obligation of liability connected with the unit.

LIMITATION OF LIABILITY

It is expressly agreed and understood that this warranty is

Hussong Manufacturing Co., Inc.‟s sole obligation and purchaser‟s exclusive remedy for defective fireplace equipment.

Hussong Manufacturing C., Inc. shall not be liable for any c o n s e q u e n t i a l , i n c i d e n t a l o f c o n t i n g e n t damages whatsoever. The foregoing warranty is exclusive and in l i e u o f a l l o th e r e x p r e ss e d wa r r a n t i e s. H u s so n g

Manufacturing Co., Inc. shall not be held to implied warranties or merchantability and fitness for a particular purpose. This warranty replaces all previous warranty policies.

Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations on how long an implied warranty lasts, so the above limitations or exclusions may not apply to you. This warranty gives you specific legal rights and you may also have other rights which vary from state to state.

Hussong Manufacturing Co., Inc. reserves the right to make c h a n g e s a t a n y t i m e , w i t h o u t n o t i c e , i s d e s i g n , m a t e r i a l , s p e c i f i c a t i o n s a n d p r i c e s . H u s s o n g

Manufacturing Co., Inc. reserves the right to discontinue models and products.

WARRANTY CONDITIONS AND REQUIREMENTS

1. You are the original purchaser. This warranty is not transferable.

2. Installation of the fireplace is performed by a qualified installer.

3. Installation and operation must comply with installation and operation instructions.

4. Paine and glass gaskets are covered for 30 days from date of purchase.

5. Components (including glass panels) broken, during shipping, careless handling of components, or defects resulting from improper installation, misuse of the fireplace and components are not covered under this warranty.

6. This warranty does not cover any part of the fireplace or any components which have been exposed to or submerged under water.

7. Hussong Manufacturing Co., Inc. must be notified by the dealer the fireplace was purchased from or a qualified installer or service technician of the defect.

8. Annual service of the fireplace as required in the installation manual, is performed by a qualified installer/service technician. (Copies of such service records may be required to claim a warranty).

9. All previous warranty/service has been performed by a qualified installer or service technician. (Copies of such service records may be required to claim a warranty).

PAGE 46

LIFETIME WARRANTY

THIS LIFETIME WARRANTY COVERAGE WILL BE EXTENDED AS DESCRIBED BELOW PROVIDED ALL WARRANTY

CONDITIONS AND REQUIREMENTS ARE MET AS OUTLINED IN THE 10 YEAR LIMITED WARRANTY POLICY.

LIFETIME WARRANTY COVERAGE

LIFETIME WARRANTY IS EXTENDED AS FOLLOWS: Hussong Manufacturing warranties to the original purchaser that the firebox, heat exchanger, fiber logs, burner tube and glass of this Ambiance fireplace will not be defective in material or workmanship under normal use and service for as long as you own this product. If any of these components fail due to defects in material or workmanship under normal use and service, Hussong Manufacturing Co., Inc. will, at its sole discretion, repair or replace the defective components. This LIFETIME WARRANTY does not cover any installation, labor, transportation or other indirect costs arising from defective components.

LIMITATION OF LIABILITY

This Lifetime warranty will be void if the fireplace is not installed by a qualified installer and according to the installation instructions. Use of unauthorized components will make this warranty null and void.

This Lifetime Warranty also is void if the fireplace is not operated, at all times, according to the operating instructions furnished. This warranty is limited to defects in material and workmanship of components specified, It does not apply to any product that has been subject to negligence, misapplication, improper installation. 1

No person is authorized to extend this Lifetime

Warranty or to accept on Hussong Manufacturing

Co., Inc.‟s behalf any additional obligation of liability connected with the unit.

Hussong Manufacturing Co., Inc. may fully discharge all obligations with respect to this Lifetime

Warranty by refunding the wholesale price of the defective component(s).

It is expressly agreed and understood that this

Lifetime Warranty is Hussong Manufacturing Co.,

Inc.‟s sole obligation and original purchaser‟s exclusive remedy for defective fireplace equipment.

Hussong Manufacturing Co., Inc. shall not be liable for any consequential, incidental or contingent damages whatsoever other than those incurred by

Hussong Manufacturing Co., Inc. to repair or replace the defective component. The foregoing warranty is exclusive and in lieu of all other expressed w a r r a n t i e s . H u s s o n g M a n u f a c t u r i n g C o . ,

Inc. shall not be held to implied warranties or merchantability and fitness for a particular purpose.

This lifetime warranty replaces all previous lifetime warranty policies.

Hussong Manufacturing Co., Inc. reserves the right to make changes at any time, without notice, in design, material, specifications and prices. Hussong

Manufacturing Co., Inc. reserves the right to discontinue models and products.

June 2011

CUT ALONG DOTTED LINE

TO ACTIVATE THIS LIFETIME WARRANTY COVERAGE, THIS REGISTRATION CARD MUST BE COMPLETED AND

MAILED WITH YOUR COMPLETED 10 YEAR LIMITED WARRANTY FORM WITHIN 30 DAYS OF INSTALLATION TO:

Hussong Manufacturing Co., Inc.

P.O. Box 577

Lakefield, Minnesota 56150

PURCHASER NAME:

ADDRESS:

TELEPHONE:

INSTALLER NAME:

ADDRESS:

TELEPHONE:

INSTALLATION DATE:

MODEL #:

SERIAL #:

PAGE 47