IP Link® De vice Interface
Communication Sheet
dukn_16_4091_1.pke
Revision: 3/2/2010
This document provides additional assistance with wiring your Extron IP Link enabled product to your device.
Different components may require a different wiring scheme than those listed below.
For complete operating instructions, refer to the user's manual for the specific Extron IP Link enabled product or
the controlled device manufacturer supplied documentation.
Device Specifications:
Device Type:
Manufacturer:
Firmware Version:
Model(s):
Document Camera
Dukane
N/A
DVP505A
Version History:
Driver
Version
Date
1
3/1/2010
IP Link
Compiler
GC
Version
1.4.0
3.0.2
Notes
Initial version.
Driver Notes:
Driver is unidirectional.
Page 1 of 3
IP Link® De vice Interface
Communication Sheet
dukn_16_4091_1.pke
Revision: 3/2/2010
Control Commands & States:
Auto Focus
Execute
Flip
On
Off
Focus
Near
Far
Freeze
On
Off
Gamma
Photo
T ext
Image
Normal
Gray
Input
Display
VGA
Lamp
On
Off
Backlight
Lens
Normal
Macro
Microscope
Powe r Control
On
Off
Zoom
T ele
Wide
Inverted
Status Available: N/A
MLC62 Supported Commands:
Auto Focus
Execute
Flip
On
Off
Focus
Near
Far
Freeze
On
Off
Gamma
Photo
T ext
Image
Normal
Gray
Input
Display
VGA
Lamp
On
Off
Backlight
Lens
Normal
Macro
Microscope
Powe r Control
On
Off
Zoom
T ele
Wide
Page 2 of 3
Inverted
dukn_16_4091_1.pke
IP Link® De vice Interface
Communication Sheet
Revision: 3/2/2010
Cable and Adapter Requirements:
M/F RS-232 straight serial cable (Extron Electronics P/N 26-433-XX)
Notes for the Device:
Serial communication:
Port Type : RS-232
Baud Rate: 9600
Data Bits: 8
Parity: None
Stop Bits: 1
Flow Control: None
Pin Assignments Diagram:
Note: Captive screw connector may also be used as a serial connection.
General Notes: