Agilent N6700 MPS Low-Profile Modular Power System Models: N6700B, N6710B, N6731B-36B, N6741B-46B, N6751A, N6752A, N6761A, N6762A Product Overview New! Higher voltage and higher current models • Ideal for ATE systems in R&D, Design Validation, and Manufacturing • Small size: up to 4 outputs in 1U of rack space • Flexible, modular system: Can mix and match power levels and performance levels to optimize investment • Performance modules for critical test requirements • Value modules for basic DC power requirements • Fast command processing times to improve throughput • Connect via GPIB, LAN, or USB Agilent Technologies If you are using Agilent Multiple-Output System DC Power Supplies Now The N6730 and N6740 Families: Basic Modules when you just need a simple power supply Models Not all applications require high performance power supplies. When your budget is tight, and when speed and accuracy are a low consideration, the Agilent N6700 LowProfile MPS supports basic DC power modules that provide an economical solution. The N6730 and N6740 families give you clean, reliable DC power without advanced features. 6621A, 6622A, 6623A, 6624A, 6625A, 6626A, 6627A, 6628A, 6629A If you would like to take advantage of the size and speed of the N6700, and need assistance in converting from Agilent 662x to the N6700, please refer to “Application Note 1467– How to use the Agilent N67xxA Modular Power System to replace an Agilent 662xA”. Look for literature part number 5989-0466EN at www.agilent.com/find/N6700 The Agilent N6730 family of 50 W DC Power Modules and the N6740 family of 100 W DC Power Modules provide the following: • Fully programmable Constant Voltage/Constant Current DC Source • Remote sensing for accurate control of output voltage when voltage drops in the leads are present • Built-in measurements of voltage and current • Protection (over-voltage over-current, and overtemperature) against damage to your DUT or to the power module 11 • Performance (programming accuracy, measurement accuracy, noise) suitable for most common DC power applications • Built-in optional output disconnect relays, which break both the power and the sense leads, to simplify system wiring Use the N6730/40 in Place of Fixed-output DC Power Supplies Many ATE systems have complex fixtures that contain indicator lights, relays or active circuits (like sensors, triggers, amplifiers) to facilitate testing of the DUT. These circuits need DC power, too. One solution for powering these ATE system resources would be to purchase a fixedoutput DC source. However, there are considerations when integrating a fixed output DC source into an ATE system. The table below illustrates these points and how it may be easier, faster, and more economical to purchase an N6730/40 programmable DC Power Module in place of a fixed-output DC Power Supply. All the benefits of the N6700 MPS at a low price While the N6730/40 are economical solutions to basic DC power requirements, they are also part of the N6700 MPS. Therefore, while saving, you still have the benefits of: Factor Consideration When Using a Fixed-Output DC Power Supply Solution Using N6730/40 DC Power Modules in N6700 MPS Control the output You may want some limited control over this DC source (on/off). The N6730/40 is fully controllable over LAN, USB, GPIB Monitor the output You may want to be able to monitor the voltage or current to ensure proper operation, which would require wiring to a system DMM. The N6730/40 has built-in measurements of voltage and current, eliminating the need for wiring to a system DMM. Mounting the power supply You will need to mount the power supply in the ATE system. Finding a safe location can be a challenge. Some system designers will build a “drawer” or “tray” for holding power supplies. However, this adds extra design time, fabrication costs, installation costs, and occupies rack space. The N6730/40 are compact modules integrated into a 1U rack mountable mainframe. There is no need to design or build any custom mounting hardware. Safety You may want to provide a safety interlock to this DC source. This would require control (on/off) and a means to detect the interlock condition. The N6730/40 have hardware inputs for remote on/off that can be directly connected to a safety interlock system. • Small size (true 1U) • Mix-and-match with other N6700 DC Power Modules when you need performance along with basic DC outputs • Connectivity via LAN, USB, and GPIB • Fast command processing time of less than 1 ms • Remote control over internet via standard web browser • Friendly front panel • Optional output disconnect relays 12 Performance Specifications Unless otherwise noted, specifications are warranted over the ambient temperature range of 0 to 55°C, and derated above 40°C. N6751A / N6752A N6761A / N6762A 50 V 5 A / 10 A 50 W / 100 W 50 V 1.5 A / 3 A 50 W / 100 W CV peak-to-peak 1 CV rms 6 mV 1 mV 6 mV 1 mV Voltage Current 2 mV 2 mA 0.5 mV 30 µA Voltage Current 1 mV 1 mA 1 mV 30 µA Voltage high range Voltage low range (≤ 5.5 V) Current high range Current low range (≤ 100 mA, @ 0 - 7 V) NOTE 2 (≤ 100 mA, @ 0 - 50 V) 0.06% + 19 mV N/A 0.1% + 20 mA N/A N/A 0.016% + 6 mV 0.015% + 1.5 mV 0.04% + 200 µA 0.04% + 15 µA 0.04% + 55 µA Voltage high range Voltage low range (≤ 5.5 V) Current high range Current low range (≤ 100 mA, @ 0 - 7 V) NOTE 2 (≤ 100 mA, @ 0 - 50 V) 0.05% + 20 mV N/A 0.1% + 4 mA N/A N/A 0.016% + 6 mV 0.016% + 1.5 mV 0.03% + 200 µA 0.03% + 15 µA NOTE 3 0.03% + 55 µA Voltage settling band Time ± 75 mV < 100 µs DC Output Ratings Voltage Current Power Output Ripple and Noise (PARD) (from 20 Hz – 20 MHz) Load Effect (Regulation) (for any output load change, with a maximum load-lead drop of 1 V per lead) Source Effect (Regulation) Programming Accuracy (at 23°C ±5°C after 30 minute warm-up. Applies from min. to max. programming range) Measurement Accuracy (at 23°C ±5°C) Load Transient Recovery Time (time to recover to within the settling band following a load change) • from 60% to 100% and from 100% to 60% of full load for models N6751A & N6761A • from 50% to 100% and from 100% to 50% of full load for models N6752A & N6762A. 1 For typical values, refer to Supplemental Characteristics. 2 Requires a 3 minute wait if you have entered the 0- 7 V range from a voltage greater than 7 V.. 3 Applies when measuring 4006 data points (SENSe:SWEep:POINts = 4096). 13 ± 75 mV < 150 µs Performance Specifications (Continued) Unless otherwise noted, specifications are warranted over the ambient temperature range of 0 to 55°C, and derated above 40°C. N6731B/ N6741B N6732B/ N6742B N6733B/ N6743B N6734B/ N6744B N6735B/ N6745B N6736B/ N6746B 5V 10 A / 20 A 50 W / 100 W 8V 6.25 A / 12.5 A 50 W / 100 W 20 V 2.5 A / 5 A 50 W / 100 W 35 V 1.5 A / 3 A 50 W / 100 W 60 V 0.8 A / 1.6 A 50 W / 100 W 100 V 0.5 A / 1A 50 W / 100 W 10 mV / 11 mV 2 mV 12 mV 2 mV 14 mV 3 mV 15 mV 5 mV 25 mV 9 mV 30 mV 18 mV Voltage Current 4 mV 2 mA 4 mV 2 mA 4 mV 2 mA 5 mV 2 mA 5 mV 2 mA 5 mV 2 mA Voltage Current 1 mV 1 mA 2 mV 1 mA 2 mV 1 mA 4 mV 1 mA 6 mV 1 mA 10 mV 1 mA Voltage Current 0.1% + 19 mV 0.15% + 20 mA 0.1% + 19 mV 0.15% + 20 mA 0.1% + 20 mV 0.15% + 20 mA 0.1% + 35 mV 0.15% + 20 mA 0.1% + 60 mV 0.15% + 20 mA 0.1% + 100 mV 0.15% + 10 mA Voltage Current 0.1% + 20 mV 0.15% + 20 mA 0.1% + 20 mV 0.15% + 10 mA 0.1% + 20 mV 0.15% + 5 mA 0.1% + 35 mV 0.15% + 4 mA 0.1% + 60 mV 0.15% + 4 mA 0.1% + 100 mV 0.15% + 2 mA ± 200 mV / 300 mV 200 µs ± 200 mV / 300 mV ± 400 mV / 500 mV ± 500 mV / 1000 mV 200 µs 200 µs 200 µs DC Output Ratings Voltage Current Power Output Ripple and Noise (PARD) (from 20 Hz – 20 MHz) CV peak-to-peak CV rms Load Effect (Regulation) 1 Source Effect (Regulation) Programming Accuracy 2 (at 23°C ±5°C after a 30 minute warm-up) Measurement Accuracy (at 23°C ±5°C) Load Transient Recovery Time (time to recover to within the settling band following a load change from 50% to 100% and from 100% to 50% of full load.) Voltage settling band Time ± 80 mV / 100 mV 200 µs ± 80 mV / 100 mV 200 µs 1 With an output change from no load to full load, up tp a maximum load-lead drop of 1 V per lead. 2 Applies from minimum to maximum programming range. (see Supplemental Characteristics) 14 Supplemental Characteristics Supplemental characteristics are not warranted but are descriptions of performance determined either by design or type testing. All characteristics are typical unless otherwise noted. N6751A / N6752A N6761A / N6762A Voltage high range Voltage low range (≤ 5.5 V) Current high range Current low range (≤ 0.1 A) 20 mV – 51 V N/A 10 mA – 5.1 A/10 mA – 10.2 A N/A 15 mV – 51 V 12 mV – 5.5 V 1 mA – 1.53 A/1 mA – 3.06 A 0.1 mA – 0.1 A Voltage high range Voltage low range (≤ 5.5 V) Current high range Current low range (≤ 0.1 A) 3.5 mV N/A 3.25 mA N/A 880 µV 90 µV 60 µA 2 µA Voltage high range Voltage low range (≤ 5.5 V) Current high range Current low range (≤ 0.1 A) 1.8 mV N/A 410 µA N/A 440 µV 44 µV 30 µA 1 µA Voltage high range Voltage low range (≤ 5.5 V) Current high range Current low range (≤ 0.1 A) 18 ppm + 160 µV N/A 100 ppm + 45 µA N/A 18 ppm + 140 µV 40 ppm + 70 µV 33 ppm + 10 µA 60 ppm + 1.5 µA Voltage high range Voltage low range (≤ 5.5 V) Current high range Current low range (≤ 0.1 A) 25 ppm + 35 µV N/A 60 ppm + 3 µA N/A 23 ppm + 40 µV 30 ppm + 40 µV 40 ppm + 0.3 µA 50 ppm + 0.3 µA Voltage, from no load to full load Current, from no load to full load 1 mV 1 mA 0.5 mV 5 µA Output Ripple and Noise (PARD) Typical CV peak-to-peak CC rms 4 mV 2 mA 4 mV 2 mA 500 µA < 2 mA 500 µA < 2 mA Programming Ranges Programming Resolution Measurement Resolution Programming Temperature Coefficient per °C Measurement Temperature Coefficient per °C Load Cross Regulation Common Mode Noise (from either output to chassis) rms (20 Hz - 20 MHz) peak-to-peak (20 Hz - 20 MHz) Over-voltage Protection Accuracy Response Time 0.25% + 250 mV 0.25% + 250 mV 50 µs from ocurence of 0V condition to start of output shutdown Down-programming Capability1 Continuous power Peak current 7W 7A 1 Modules can discharge a 1000 µF capacitor from 50 V to 0 V at a rate of 4 times/second. 15 7W 3A Supplemental Characteristics (Continued) Supplemental characteristics are not warranted but are descriptions of performance determined either by design or type testing. All characteristics are typical unless otherwise noted. N6751A / N6752A N6761A / N6762A 0.2 ms 1.5 ms 0.6 ms 2.2 ms 0.5 ms 4 ms 0.9 ms 4 ms 0.3 ms 1.3 ms 0.3 ms 1.3 ms 0.45 ms 1.4 ms 0.45 ms 1.4 ms 2.1 ms 11 ms 4.5 ms 23 ms Up-programming Time with full resistive load: (time from 10% to 90% of total voltage excursion) Voltage setting from 0 V to 10 V Voltage setting from 0 V to 50 V Up-programming Settling Time with full resistive load: (time from start of voltge change to within 50 mV of final value)) Voltage setting from 0 V to 10 V Voltage setting from 0 V to 50 V Down-programming Time with no load: (time from start of voltage change to output voltage < 0.5 V) Voltage setting from 10 V to 0 V Voltage setting from 50 V to 0 V Down-programming Settling Time with no load: (time from start of voltage change to output voltage within 50 mV of final value) Voltage setting from 10 V to 0 V Voltage setting from 50 V to 0 V Down-programming Time with 1000 µF load: (time from start of voltage change to output voltage < 0.5 V) Voltage setting from 10 V to 0 V Voltage setting from 50 V to 0 V 16 Supplemental Characteristics (Continued) Supplemental characteristics are not warranted but are descriptions of performance determined either by design or type testing. All characteristics are typical unless otherwise noted. N6731B/ N6741B N6732B/ N6742B N6733B/ N6743B N6734B/ N6744B N6735B/ N6745B N6736B/ N6746B Voltage 15 mV – 5.1 V 15 mV – 8 .16 V 30 mV – 20.4 V 40 mV – 35.7 V 70 mV – 61 V 100 mV – 102 V Current 60 mA – 10.2 A/ 60 mA – 20.4 A 40 mA – 6.375 A/ 40 mA – 12.75 A 10 mA – 2.55 A/ 10 mA – 5.1 A 5 mA – 1.53 A/ 5 mA – 3.06 A 2.5 mA – 0.85 A/ 2.5 mA – 1.7 A 1.5 mA – 0.51 A/ 1.5 mA – 1.02 A Voltage Current 3.5 mV 7 mA 4 mV 4 mA 7 mV 3 mA 10 mV 2 mA 18 mV 1 mA 28 mV 0.5 mA Voltage Current 3 mV 10 mA 4 mV 7 mA 10 mV 3 mA 18 mV 2 mA 30 mV 1 mA 33 mV 0.5 mA CC rms 8 mA 4 mA 2 mA 2 mA 2 mA 2 mA 1 mA < 10 mA 1 mA < 10 mA 1 mA < 10 mA 1 mA < 10 mA 1 mA < 10 mA 1 mA < 10 mA 0.25% + 300 mV 0.25% + 300 mV Programming Ranges Programming Resolution Measurement Resolution Output Ripple and Noise (PARD) Common Mode Noise (from either output to chassis) rms (20 Hz – 20 MHz) peak-to-peak (20Hz - 20MHz) Over-voltage Protection Accuracy (without relay option) Response Time 0.25% + 250 mV 0.25% + 250 mV 0.25% + 250 mV 0.25% + 250 mV 50 µs from occurence of 0V condition to start of output shutdown Maximum Up-programming and Down-programming Time with full resistive load: (time from 10% to 90% of total voltage excursion) Voltage setting from 0 V to full scale and full scale to 0 V 20 ms 20 ms 20 ms 20 ms 20 ms 20 ms 100 ms 100 ms 100 ms 100 ms 100 ms Maximum Up-programming and Down-programming Settling Time with full resistive load: (time from start of voltage change until voltage settles within 0.1% of the full-scale voltage of its final value) Voltage setting from 0 V to full scale and full scale to 0 V 100 ms Remote Sense Capability: Outputs can maintain specifications with up to a 1-volt drop per load lead. Series and Parallel Operation: Similarly rated outputs can be operated directly in parallel or can be connected for straight series operation. Auto-series and auto-parallel operation is not available. 17 Supplemental Characteristics (Continued) Supplemental characteristics are not warranted but are descriptions of performance determined either by design or type testing. All characteristics are typical unless otherwise noted. N6700B MPS Mainframe Output Response Characteristics Command processing time Protection Response Characteristics Inhibit Input 5 µs (from receipt of inhibit to start of shutdown) Fault on coupled outputs < 10 µs (from receipt of fault to start of shutdown) Maximum voltage ratings +16.5 VDC/-5 VDC between pins (pin 4 is internally connected to chassis ground). Pins 1 and 2 as FLT output Maximum low-level output voltage = 0.5 V @ 4 mA Maximum low-level sink current = 4 mA Typical high-level leakage current = 0.14 mA @ 16.5 VDC Pins 1 thru 8 as digital/trigger outputs (pin 4 = common) Maximum low-level output voltage = 0.5 V @ 4 mA; 1 V @ 50 mA; 1.75 V @ 100 mA Maximum low-level sink current = 100 mA Typical high-level leakage current = 0.12 mA @ 16.5 VDC Pins 1 thru 8 as digital/trigger inputs and pin 3 as INH input (pin 4 = common) Maximum low-level input voltage = 0.8 V Minimum high-level input voltage = 2 V Typical low-level current = 2 mA @ 0 V (internal 2.2k pull-up) Typical high-level leakage current = 0.12 mA @ 16.5 VDC Digital Control Characteristics ≤ 1 ms from receipt of command to start of the output change Interface Capabilities GPIB SCPI - 1993, IEEE 488.2 compliant interface USB 2.0 Requires Agilent I/O Library version M.01.01.04 10/100 LAN Requires Agilent I/O Library version L.01.01 Web server Built-in Web server - requires Internet Explorer 5+ or Netscape 4.x Environmental Conditions 1Category Operating environment Indoor use, installation category II1, pollution degree 2 Temperature range 0˚C to 55˚C (output derated above 40˚C) Relative humidity Up to 95% Altitude Up to 2000 meters Storage temperature -30˚C to 70˚C II for AC input. 18 Supplemental Characteristics (Continued) Supplemental characteristics are not warranted but are descriptions of performance determined either by design or type testing. All characteristics are typical unless otherwise noted. N6700B MPS Mainframe Regulatory Compliance EMC Complies with the European EMC directive 89/336/EEC for Class A test and measurement products. Complies with the Australian standard and carries the C-Tick mark. This ISM device complies with Canadian ICES-001. Cet appareil ISM est conforme à la norme NMB-001 du Canada. Electrostatic discharges greater than 1 kV near the I/O connectors may cause the unit to reset and require operator intervention. Acoustic Noise Declaration Safety Complies with the European Low Voltage Directive 73/23/EEC and carries the CE-marking. This product also complies with the US and Canadian safety standards for test and measurement products. This statement is provided to comply with the requirements of the German Sound Emission Directive, from 18 January 1991. Sound Pressure Lp < 70 dB(A), At Operator Position, Normal Operation, According to EN 27779 (Type Test). Schalldruckpegel Lp <70 dB(A) Am Arbeitsplatz, Normaler Betrieb, Nach EN 27779 (Typprüfung). * * * * * * Isolation No output terminal may be more than 240 VDC from any other terminal or chassis ground. AC Input Nominal Input Ratings 100 VAC – 240 VAC; 50/60/400 Hz Input Range 86 VAC – 264 VAC Power Consumption 1000 VA typical; 1100 VA maximum (with power factor correction) Fuse Internal fuse (not customer accessible) Mainframe Dimensions Height: 44.45 mm; 1.75 in. Width: 432.5 mm; 17.03 in. Depth: 596.9 mm; 23.5 in. With 4 installed modules Net: 12.78 kg; 28 lbs. Mainframe Weight 19 Agilent N67xxA Option Characteristics Output Relay Option Mechanical relays that break conduction path on + output, - output, + sense, - sense. Relays sequenced to ensure no loss of control when sense lines are opened. Autoranging Characteristic Voltage Autoranging 50 W Output 50 V 50 W Curve 10 V High Speed Test Extensions List mode • Number of steps = 1 to 512 • Dwell time = 1 µs to 262 seconds • Maximum list repetitions = 256, or infinite 0 1A 5A Current Voltage Autoranging 100 W Output High Speed Test Extensions Digitizer • Measurement points = 1 to 4096 • Sample rate = 0.000025 Hz to 50 kHz 50 V 100 W Curve 12 V 8.5 V 0 2A 8.33 A 10 A Current Voltage Precision Outputs 50 V 33 V 0 20 1 A 1.5 A – 50 W output 2 A 3 A – 100 W output Current Right Side Outline Diagram 571.5 mm 22.5" Top of Unit 549.7 mm 21.64" 25.4 mm 1.00" 432.5 mm 17.03" 44.45 mm 1.75" 482.6 mm 19.00" Agilent Technologies = Airflow 425.45 mm 16.75" 21 Ordering Information The N6700 Modular Power System is available 2 ways: (1) You can order an N6700B mainframe and various modules as separate products. (See steps below.) Each item will arrive in a separate box such that you can assemble the system yourself when you need to. Mainframe N6700B Low-Profile Modular Power System Mainframe Holds 1 to 4 modules. Available options to N6700B N6700B-908 Rack Mount Kit Required for rack mounting. Standard rack mount hardware will not work. This N6700 Rack Mount Kit is also orderable separately as product N6709A N6700B-FLR Filler Panel Kit Required when you have < 4 modules in an N6700B. Each filler panel kit contains 3 filler panels. This N6700 Filler Panel Kit is also orderable separately as product N6708A N6700B-0L1 Standard Documentation Kit N6700B-0L2 Additional copy of Standard Documentation Kit N6700B-0B0 Delete Standard Documentation Kit N6700B-900 Power Cord, United Kingdom, P/N 8120-1351 N6700B-901 Power Cord, Australia, P/N 8120-1369 N6700B-902 Power Cord, Europe, P/N 8120-1689 N6700B-903 Power Cord, USA, Canada, P/N 8120-4383 Step 1: Order the N6700B mainframe and appropriate documentation and line cord options. N6700B-904 Power Cord, USA, Canada, P/N 8120-0698 N6700B-906 Power Cord, Switzerland, P/N 8120-2104 N6700B-912 Power Cord, Denmark, P/N 8120-2956 Step 2: Order 1 to 4 modules (see next page). N6700B-917 Power Cord, South Africa, India, P/N 8120-4211 N6700B-918 Power Cord, Japan, P/N 8120-4753 N6700B-919 Power Cord, Israel, P/N 8120-6800 N6700B-920 Power Cord, Argentina, P/N 8120-6869 N6700B-921 Power Cord, Chile, P/N 8120-6980 N6700B-922 Power Cord, China, P/N 8120-8376 N6700B-927 Power Cord, Thailand, P/N 8120-8871 (2) You can order an N6710B, which is a build-to-order system that is shipped as a fully tested and assembled multiple-output power supply. (See pages 24 and 25 for N6710B ordering information.) When ordering the N6700 MPS as a mainframe and modules, follow these steps: Step 3. For proper N6700B operation, you must fill any empty module slots with filler panels. When ordering less than 4 modules per mainframe, you MUST order an N6700B-FLR Filler Panel Kit. Each kit contains 3 filler panels. Step 4: If you will be rack mounting the N6700B, you MUST order N6700B-908 Rack Mount Kit. 22 Ordering Information Modules Order 1 to 4 modules to be installed into each N6700B mainframe. (To order modules as part of N6710B, see page 25.) You can individually specify each option for each module. For example, you can order the one module with Option 761 Output Disconnect Relays, while the remaining modules have no relay option. As your needs change and you want to change configuration or add more modules to existing N6700A or N6700B mainframes, use this ordering information to order the required modules. Modules N6730 50 W DC Power Modules N6731B 5 V, 10 A, 50 W DC Power Module N6732B 8 V, 6.25 A, 50 W DC Power Module N6733B 20 V, 2.5 A, 50 W DC Power Module N6734B 35 V, 1.5 A, 50 W DC Power Module N6735B 60 V, 0.8 A, 50 W DC Power Module N6736B 100 V, 0.5 A, 50 W DC Power Module Available options to N673xB modules N673xB–761 Output Disconnect Relays N673xB-UK6 Commercial calibration with test results data N673xB-1A7 ISO 17025 Cal certificate N6740 100 W DC Power Modules N6741B 5 V, 20 A, 100 W DC Power Module N6742B 8 V, 12.5 A, 100 W DC Power Module N6743B 20 V, 5 A, 100 W DC Power Module N6744B 35 V, 3 A, 100 W DC Power Module N6745B 60 V, 1.6 A, 100 W DC Power Module N6746B 100 V, 1 A, 100 W DC Power Module Available options to N674xB modules N674xB–761 Output Disconnect Relays N674xB-UK6 Commercial calibration with test results data N674xB-1A7 ISO 17025 Cal certificate N6750 High-Performance, Autoranging DC Power Modules N6751A N6752A Available options to N675xA modules N675xA–761 50 V, 5 A, 50 W High-Performance Autoranging DC Power Module 50 V, 10 A, 100 W High-Performance Autoranging DC Power Module Output Disconnect Relays N675xA–054 High-Speed Test Extensions N675xA-UK6 Commercial calibration with test results data N675xA-1A7 ISO 17025 Cal certificate N6760 Precision DC Power Modules N6761A N6762A Available options to N676xA modules N676xA–761 50 V, 5 A, 50 W Precision DC Power Module 50 V, 10 A, 100 W Precision DC Power Module Output Disconnect Relays <standard> High-Speed Test Extensions are included on all N676xA modules N676xA-UK6 Commercial calibration with test results data N676xA-1A7 ISO 17025 Cal certificate 23 Ordering Information N6710B Systems To purchase an N6710 Modular Power System, order an N6710B. The N6710B is a build-to-order system that is shipped as a fully tested and assembled multiple-output power supply. Each N6710B consists of 1 N6700B mainframe plus optionally 1 to 4 modules. To specify which modules you want installed in the N6710B, modules are ordered as options to the N6710B. If you order less than 4 modules, the empty slots will be automatically filled with blank filler panels. You must order at least 1 module. N6710B System Build-to-Order Modular Power System (Consists of 1 N6700B mainframe) Available options to N6710B N6710B-908 Rack Mount Kit Required for rack mounting. Standard rack mount hardware will not work. This N6700 Rack Mount Kit is also orderable separately as product N6709A N6710B-0L1 Standard Documentation Kit N6710B-0L2 Additional copy of Standard Documentation Kit N6710B-0B0 Delete Standard Documentation Kit N6710B-900 Power Cord, United Kingdom, P/N 8120-1351 N6710B-901 Power Cord, Australia, P/N 8120-1369 N6710B-902 Power Cord, Europe, P/N 8120-1689 N6710B-903 Power Cord, USA, Canada, P/N 8120-4383 N6710B-904 Power Cord, USA, Canada, P/N 8120-0698 N6710B-906 Power Cord, Switzerland, P/N 8120-2104 N6710B-912 Power Cord, Denmark, P/N 8120-2956 N6710B-917 Power Cord, South Africa, India, P/N 8120-4211 N6710B-918 Power Cord, Japan, P/N 8120-4753 N6710B-919 Power Cord, Israel, P/N 8120-6800 N6710B-920 Power Cord, Argentina, P/N 8120-6869 N6710B-921 Power Cord, Chile, P/N 8120-6980 N6710B-922 Power Cord, China, P/N 8120-8376 N6710B-927 Power Cord, Thailand, P/N 8120-8871 24 Ordering Information Modules as options to N6710B To order a module as an option to an N6710B, specify its model number, followed by “–ATO”. For example, to order an N6731B as an option to the N6710B, you would specify “N6731B –ATO” as the option. (To order modules as separate products, see page 23.) Module options for N6710B System You can individually specify each option for each module. For example, you can order the first module with Option 761 Output Disconnect Relays, while the remaining modules have no relay option. N673xB-ATO-UK6 Commercial calibration with test results data N673xB-ATO-1A7 ISO 17025 Cal certificate N6730 50 W DC Power Modules N6731B–ATO 5 V, 10 A, 50 W DC Power Module N6732B–ATO 8 V, 6.25 A, 50 W DC Power Module N6733B–ATO 20 V, 2.5 A, 50 W DC Power Module N6734B–ATO 35 V, 1.5 A, 50 W DC Power Module N6735B–ATO 60 V, 0.8 A, 50 W DC Power Module N6736B–ATO 100 V, 0.5 A, 50 W DC Power Module Available options to N673xB modules N673xB–ATO–761 N6740 100 W DC Power Modules N6741B–ATO Output Disconnect Relays 5 V, 20 A, 100 W DC Power Module N6742B–ATO 8 V, 12.5 A, 100 W DC Power Module N6743B–ATO 20 V, 5 A, 100 W DC Power Module N6744B–ATO 35 V, 3 A, 100 W DC Power Module N6745B–ATO 60 V, 1.6 A, 100 W DC Power Module N6746B–ATO 100 V, 1 A, 100 W DC Power Module Available options to N674xB modules N674xB–ATO–761 Output Disconnect Relays N674xB-ATO-UK6 Commercial calibration with test results data N674xB-ATO-1A7 ISO 17025 Cal certificate N6750 High-Performance, Autoranging DC Power Modules N6751A–ATO N6752A–ATO Available options to N675xA modules N675xA–ATO–761 50 V, 5 A, 50 W High-Performance Autoranging DC Power Module 50 V, 10 A, 100 W High-Performance Autoranging DC Power Module Output Disconnect Relays N675xA–ATO–054 High-Speed Test Extensions N675xA-ATO-UK6 Commercial calibration with test results data N675xA-ATO-1A7 ISO 17025 Cal certificate N6760 Precision DC Power Modules N6761A–ATO N6762A–ATO Available options to N676xA modules N676xA–ATO–761 50 V, 5 A, 50 W Precision DC Power Module 50 V, 10 A, 100 W Precision DC Power Module Output Disconnect Relays <standard> High-Speed Test Extensions are included on all N676xA modules N676xA-ATO-UK6 Commercial calibration with test results data N676xA-ATO-1A7 ISO 17025 Cal certificate 25 Compatibility and Upgrade Information You have with firmware and with modules If you want to … … here is what you need to do N6710A or N6700A Any version starting with A (example: A.00.00) Any combination of modules with model number N673xA, N674xA, N675xA or N676xA Add more modules with model numbers N673xA, N674xA, N675xA, or N676xA Capability available with your current version of hardware and firmware; No upgrade required. Add more modules with model numbers N673xB or N674xB Install firmware version B.00.00 or greater available at www.agilent.com/find/n6700 Add or change modules to mixand-match any combination of modules with model numbers N673xA, N673xB, N674xA, N674xB, N675xA, and N676xA Install firmware version B.00.00 or greater available at www.agilent.com/find/n6700 Add virtual channel capability for paralleling Install firmware version B.00.00 or greater available at www.agilent.com/find/n6700 Add programmable voltage slew capability Install firmware version B.00.00 or greater available at www.agilent.com/find/n6700 Add or change modules to mix-and-match any combination of modules with model numbers N673xA, N673xB, N674xA, N674xB, N675xA, and N676xA Capability available with your current version of hardware and firmware; No upgrade required. Add virtual channel capability for paralleling Capability available with your current version of hardware and firmware; No upgrade required. Add programmable voltage slew capability Capability available with your current version of hardware and firmware; No upgrade required. Add or change modules to mix-and-match any combination of modules with model numbers N673xA, N673xB, N674xA, N674xB, N675xA, and N676xA Capability available with your current version of hardware and firmware; No upgrade required. Add virtual channel capability for paralleling Capability available with your current version of hardware and firmware; No upgrade required. Add programmable voltage slew capability Capability available with your current version of hardware and firmware; No upgrade required. N6700A or N6710A N6700B or N6710B B.00.00 or greater B.00.00 or greater Any combination of modules with model number N673xA, N673xB, N674xA, N674xB, N675xA, or N676xA Any combination of modules with model number N673xA, N673xB, N674xA, N674xB, N675xA, or N676xA 26 Compatibility and Upgrade Information (Continued) You have with firmware and with modules If you want to … … here is what you need to do N6721A thru N6729A Any version starting with A (example: A.00.00) Any combination of modules with model number N675xA or N676xA Add more modules with model numbers N675xA or N676xA Capability available with your current version of hardware and firmware; No upgrade required. Add more modules with model numbers N673xA or N674xA (see note 1 below) Capability available with your current version of hardware and firmware; No upgrade required. Add more modules with model numbers N673xB or N674xB (see note 1 below) Install firmware version B.00.00 or greater available at www.agilent.com/find/n6700 Add or change modules to mix-and-match any combination of modules with model numbers N673xA, N673xB, N674xA, N674xB, N675xA, and N676xA (see note 1 below) Install firmware version B.00.00 or greater available at www.agilent.com/find/n6700 Add virtual channel capability for paralleling (see note 2 below) Install firmware version B.00.00 or greater available at www.agilent.com/find/n6700 Add programmable voltage slew capability (see note 2 below) Install firmware version B.00.00 or greater available at www.agilent.com/find/n6700 Notes: 1 If you add modules with model #’s N673xA, N673xB, N674xA, or N674xB, you will not be able to access the Agilent 662x command set compatibility of your N672xA for any installed modules. Only SCPI commands will be accepted. 2 These features are not available in the Agilent 662x command set. You must use SCPI commands to access these new programmable features. Compatibility with older models If you previously purchased an Agilent 662xA or N672xA, and you want to make another purchase, use the table at right to find the equivalent configuration of N6700B Low-Profile Modular Power System Mainframe and DC Power Modules. Older Agilent Model A version model number Equivalent configuration with latest N6700 series models 6621A N6721A N6700B + 2 x N6752A 6622A N6722A N6700B + 2 x N6752A 6623A N6723A N6700B + 2 x N6751A 1 x N6752A 6624A N6724A N6700B + 4 x N6751A 6625A N6725A N6700B + 1 x N6761A 1 x N6762A 6626A N6726A N6700B + 2 x N6761A 2 x N6762A 6627A N6727A N6700B + 4 x N6751A 6628A N6728A N6700B + 2 x N6762A 6629A N6729A N6700B + 4 x N6762A 27 Agilent Technologies’ Test and Measurement Support, Services, and Assistance Agilent Technologies aims to maximize the value you receive, while minimizing your risk and problems. We strive to ensure that you get the test and measurement capabilities you paid for and obtain the support you need. Our extensive support resources and services can help you choose the right Agilent products for your applications and apply them successfully. Every instrument and system we sell has a global warranty. Support is available for at least five years beyond the production life of the product. Two concepts underlie Agilent’s overall support policy: “Our Promise” and “Your Advantage.” Our Promise Our Promise means your Agilent test and measurement equipment will meet its advertised performance and functionality. When you are choosing new equipment, we will help you with product information, including realistic performance specifications and practical recommendations from experienced test engineers. When you use Agilent equipment, we can verify that it works properly, help with product operation, and provide basic measurement assistance for the use of specified capabilities, while your instrument is under warranty or technical support contract. Many self-help tools are available on Agilent’s web site. Your Advantage Your Advantage means that Agilent offers a wide range of additional expert test and measurement services, which you can purchase according to your unique technical and business needs. Solve problems efficiently and gain a competitive edge by contracting with us for calibration, extra-cost upgrades, out-of-warranty repairs, and on-site education and training, as well as design, system integration, project management, and other professional engineering services. Experienced Agilent engineers and technicians worldwide can help you maximize your productivity, optimize the return on investment of your Agilent instruments and systems, and obtain dependable measurement accuracy for the life of those products. Agilent Email Updates By internet, phone, or fax, get assistance with all your test & measurement needs Online assistance: www.agilent.com/find/assist Phone or Fax United States: (tel) 1 800 829 4444 Canada: (tel) 1 877 894 4414 (fax) (905) 282 6495 China: (tel) 800 810 0189 (fax) 800 820 2816 Europe: (tel) (31 20) 547 2323 (fax) (31 20) 547 2390 Japan: (tel) (81) 426 56 7832 (fax) (81) 426 56 7840 Korea: (tel) (82 2) 2004 5004 (fax) (82 2) 2004 5115 Latin America: (tel) (305) 269 7500 (fax) (305) 269 7599 www.agilent.com/find/emailupdates Get the latest information on the products and applications you select. Taiwan: (tel) 0800 047 866 (fax) 0800 286 331 Agilent Direct Other Asia Pacific Countries: (tel) (65) 6375 8100 (fax) (65) 6836 0252 Email: tm_asia@agilent.com www.agilent.com/find/agilentdirect Quickly choose and use your test equipment solutions with confidence. Agilent T&M Software and Connectivity Agilent’s Test and Measurement software and connectivity products, solutions and developer network allows you to take time out of connecting your instruments to your computer with tools based on PC standards, so you can focus on your tasks, not on your connections. Visit www.agilent.com/find/connectivity for more information. Product specifications and descriptions in this document subject to change without notice. For latest and complete specifications, refer to the N6700 User’s Guide, Agilent part number 5969-2908. The web contains the most up-to-date version of the User’s Guide. Go to http://www.agilent.com/find/N6700. © Agilent Technologies, Inc. 2004 Printed in the USA August 5, 2004 5989-1411EN Agilent Technologies