DX-D 400
GENERATORS
Generator model
DX-D 400
S calable radiography system
Why Agfa HealthCare?
SHF 345
(CR only)
SHF 545
SHF 645
DX-D 400
SHF 845
Agfa HealthCare is a global leader in the fast growing market of integrated IT and imaging systems, offering
healthcare facilities a seamless flow of information and a 360º view of patient care. The company has a unique,
holistic approach, enabling it to provide in-depth clinical know-how and fully integrated hospital-wide solutions.
These specialized solutions integrate IT and imaging systems for Radiology, Cardiology, Mammography and
Orthopaedics. Agfa HealthCare’s enterprise-wide IT platform integrates all administrative and clinical data within a
healthcare facility and is designed to match the unique needs of specific healthcare professionals.
DX-D 400
Input power
3 Phase 480
Max. power (kW) 32
50
64
80
Max. mA
400
640
640
800
Power output @ 0.1s
640 mA @ 78 kVp
640 mA @ 80 kVp
800 mA @ 80 kVp
500 mA @ 100 kVp
640 mA @ 100 kVp
800 mA @ 100 kVp
confidence. The system is floor-mounted and therefore easy
400 mA @ 125 kVp
500 mA @ 128 kVp
640 mA @ 125 kVp
to install, requiring little space and without an expensive
320 mA @ 150 kVp
400 mA @ 150 kVp
500 mA @ 150 kVp
E7252X, E7254FX,
E7254FX, E7869X
Compatible X-ray All
All
Tubes
The DX-D 400 system is a flexible and affordable solution
designed for patient comfort and to enhance radiographer
www.agfahealthcare.com
ceiling structure. The DX-D 400 has adaptable configurations
which can be tailored to the specific needs of your practice.
High quality precision hardware helps maximize uptime -
E7869X
important in a busy imaging environment. The robust table
Range of radiographic parameters
mA
From 10 mA to 800 mA through the following mA stations: 10, 12.5, 16, 20, 25, 32, 40, 50, 64,
80, 100, 125, 160, 200, 250, 320, 400, 500, 640, 800.(Depending on the Generator model)
mAs
Product of mA x time values from 0.1 mAs to 500 mAs
ms
From 1 to 10000 milliseconds through the following time stations: 1, 2, 3, 4, 5, 6, 8, 10, 12, 16,
20, 25, 32, 40, 50, 64, 80, 100, 125, 160, 200, 250, 320, 400, 500, 640, 800, 1000, 1250, 1600,
2000, 2500, 3200, 4000, 5000. 6400, 8000 and 10000.
with floating table top allows for easy positioning. Safety
features, such as double touch foot switches, are built into
the product.
SCALABLE AND AFFORDABLE FLOOR-MOUNTED
RADIOGRAPHY SYSTEM.
AEC (Automatic mAs: 0.1 mAs to 500 mAs exposure time: Nominal shortest irradiation time = 1 ms
Exposure Control)
• Flexible configurations and options
• Floor-mounted for cost-effective and easy
installation and use
• Solid precision components offer reliability and
help maximum uptime • Can be combined with Agfa HealthCare CR systems
for even greater versatility
X-RAY TUBES
5
Housing
Focal spot
Target angle
Heat capacity (kHU)
Anode speed
Toshiba E7884X
0.6 – 1.2
12°
300
Low
Toshiba E7252X
0.6 – 1.2
12°
300
High/Low
Toshiba E7254FX
0.6 – 1.2
12°
400
High/Low
Toshiba E7869X
0.6 – 1.2
12°
600
High/Low
Agfa and the Agfa rhombus are trademarks of Agfa-Gevaert N.V., Belgium, or its affiliates. MUSICA and DX-D are
trademarks of Agfa HealthCare NV, Belgium or its affiliates. All other trademarks are held by their respective
owners and are used in an editorial fashion with no intention of infringement. The data in this publication are
for illustration purposes only and do not necessarily represent standards or specifications, which must be met
by Agfa HealthCare. All information contained herein is intended for guidance purposes only, and characteristics
of the products and services described in this publication can be changed at any time without notice. Products
and services may not be available for your local area. Please contact your local sales representative at agfa.com
for availability information. Agfa HealthCare diligently strives to provide as accurate information as possible, but
shall not be responsible for any typographical error.
© 2011 Agfa HealthCare Corp.
All rights reserved
Published by
Agfa HealthCare Corp.
10 South Academy Street
Greenville, SC 29601 USA
5SJ8D US 00201108
DX-D 400
Flexible to meet every need
Services & Support
With its configurations and range of options, the DX-D 400
Agfa HealthCare offers service agreement solutions
will fit with many imaging environments. The Analog
tailored to the individual customer’s situation. The service
Manual configuration includes a radiographic floating
agreements are available in Basic, Advantage and PM Only
fixed-height table and an analog tubehead control panel.
levels, making lifecycle costs predictable.
The Analog Manual (D) version offers an elevating floating
table with a maximum weight limit of 350 kg (771 lbs) and a
digital tubehead control panel.
A worldwide team of some 1,000 service professionals is at
your disposal to provide support at all phases of your project.
As an additional service, they can help you customize your
Both configurations can be enhanced with options such as a
examination tree or link RIS protocol codes for an even
wall stand with a tilting bucky, which provides the operator
higher return on investment. Furthermore, this team carries
with versatility for any type of exam.
out tasks that go well beyond maintenance, including value
added services such as super user training, staff training and
software upgrades.
Floor-mounted suspension: ease of installation and
use
Floor-mounted, the DX-D 400 does not require an expensive
ceiling structure and is quick and easy to install. Its compact
size (4 x 2 m) means it fits into even limited spaces. Yet, with
the touch screen control console (with editable APR, ability
to store new edited studies, functional grouping of controls
and indicators and six selectable patient sizes including three
for children), it still offers complete ease of use. This efficient
design adds to its flexibility.
Solid precision hardware
DX-D 400
DX-D 400
technical
• Lateral cassette holder 24 x 30
COLLIMATORS
• Inherent filtration
S P E C I F I C AT I O N S
PATIENT TABLE (ELEVATING and
NON-ELEVATING)
Dimensions
FLOOR MOUNTED TUBESTAND
• Tubestand longitudinal travel
2 m (optional 3 m)
(78.74 in (optional 118.11 in))
• Height
750 mm (29.53 in)
• Table base length
800 mm (31.5 in)
Tubestand dimensions
• Table base width
2200 mm (86.61 in)
• Height
2370 mm (93.31 in)
• Tabletop width
800 mm (31.5 in)
• Length of base
2755 mm (108.46 in)
• Tabletop length
2200 mm (86.61 in)
• Width
1267 mm (49.88 in)
• Tabletop film distance
85 mm (3.35 in)
• Tube arm extension distance 300 mm (11.8 in)
• X-ray absorption
< 1.0 mm Al
• Maximum height of X-ray tube
(0.04 in) equivalent
focal spot (vertical position)
• Tabletop travel longitudinal
1100 mm (43.31 in)
• Tabletop travel transverse
240 mm (9.45 in)
Distances from X-ray tube focal spot facing the wall
• Tabletop material
Carbon fiber
stand bucky
• Max. patient weight
350 kg (771 lbs)
• Minimum height
400 mm (15.75 in)
• Bucky travel along table access 51 cm (20.08 in)
• Maximum height
1900 mm (74.8 in)
• Automatic exposure control
3-field solid state
• Column longitudinal motion
2010 mm (79.13 in)
sensors
• Rotation of column with respect
• Grid
1 m (39.37 in)
PATIENT TABLE (ELEVATING)
900 mm (35.43 in)
transverse axis (rotation may be
• Minimum height
500 mm (19.69 in)
limited by cables)
• Vacudap 2004 (external dose area meter)
200 lx
• Additional filtration 1 mm Al + 0.1 mm Cu
INSTALLATION DATA
1 mm Al + 0.2 mm Cu
• Line voltage
2 mm Al or 1 mm Al
(additional transformer required for 80 kW generator
• Rotation
up to maximum
± 90°
2020 mm (79.53 in)
Automatic line compensation
± 10 %
• Power consumption
105 kVA (Gen 64 kW);
• Height
2235 mm (87.99 in)
• Width
620 mm (24.41 in)
• Depth
345 mm (13.58 in)
3-phase, 480 v 60 Hz
below 480 v)
• Radiographic Table
Dimensions
• Ceiling height
120 kVA (Gen 80 kW)
Single phase 110 V~
60 Hz
2.60 - 2.80 m (102.36 -
110.24 in)
(for normal use)
Height from floor to center of active imaging area
• Minimum height 400 mm (15.75 in)
Ambient conditions (operation)
• Maximum height
1900 mm (74.8 in)
Temperature range
+15° C to +30° C
• Bucky vertical motion
1500 mm (59.06 in)
Storage/Transport temperature
-20° C to +70° C
• Surface plane - film distance 44 mm (1.73 in)
Relative humidity (no condensing) 30 % to 75 %
• Radiation absorption < 0.8 mm Al
Atmospheric pressure
± 180°
• Automatic exposure control
± 150°
700 hPA to 1060 hPa
equivalent
3-field solid state
PRODUCT WEIGHTS
sensors
Patient table: non elevating: 190 kg (418.88 lbs)
• Scatter radiation grid
150/180 cm option
Patient table: elevating: 280 kg (617.29 lbs)
(59.06/70.87 in)
Floor mounted tubestand: 345 kg (760.59 lbs)
Wall stand: 145 kg (319.67 lbs)
Assembly with respect to its
• Maximum height
equivalent
WALL STAND
• Rotation of Tube-Collimator
Vertical travel
• Lateral cassette holder 35 x 43
• Full field light localizer
to its vertical axis (rotation may
be limited by cables)
2 mm aluminum SYSTEM ACCESSORIES
• Compression band
From the robust radiographic table, to the wall stand, to
• Hand grips for table
the tubehead and beyond, the DX-D 400 offers high quality,
• Hands support for wall stand
precision hardware for all its components. By improving
uptime and reliability, productivity is increased and reduced
maintenance equals a lower total cost of ownership (TCO)
and better protection of the hospital or clinic’s investment.
2
3
4
DX-D 400
Flexible to meet every need
Services & Support
With its configurations and range of options, the DX-D 400
Agfa HealthCare offers service agreement solutions
will fit with many imaging environments. The Analog
tailored to the individual customer’s situation. The service
Manual configuration includes a radiographic floating
agreements are available in Basic, Advantage and PM Only
fixed-height table and an analog tubehead control panel.
levels, making lifecycle costs predictable.
The Analog Manual (D) version offers an elevating floating
table with a maximum weight limit of 350 kg (771 lbs) and a
digital tubehead control panel.
A worldwide team of some 1,000 service professionals is at
your disposal to provide support at all phases of your project.
As an additional service, they can help you customize your
Both configurations can be enhanced with options such as a
examination tree or link RIS protocol codes for an even
wall stand with a tilting bucky, which provides the operator
higher return on investment. Furthermore, this team carries
with versatility for any type of exam.
out tasks that go well beyond maintenance, including value
added services such as super user training, staff training and
software upgrades.
Floor-mounted suspension: ease of installation and
use
Floor-mounted, the DX-D 400 does not require an expensive
ceiling structure and is quick and easy to install. Its compact
size (4 x 2 m) means it fits into even limited spaces. Yet, with
the touch screen control console (with editable APR, ability
to store new edited studies, functional grouping of controls
and indicators and six selectable patient sizes including three
for children), it still offers complete ease of use. This efficient
design adds to its flexibility.
Solid precision hardware
DX-D 400
DX-D 400
technical
• Lateral cassette holder 24 x 30
COLLIMATORS
• Inherent filtration
S P E C I F I C AT I O N S
PATIENT TABLE (ELEVATING and
NON-ELEVATING)
Dimensions
FLOOR MOUNTED TUBESTAND
• Tubestand longitudinal travel
2 m (optional 3 m)
(78.74 in (optional 118.11 in))
• Height
750 mm (29.53 in)
• Table base length
800 mm (31.5 in)
Tubestand dimensions
• Table base width
2200 mm (86.61 in)
• Height
2370 mm (93.31 in)
• Tabletop width
800 mm (31.5 in)
• Length of base
2755 mm (108.46 in)
• Tabletop length
2200 mm (86.61 in)
• Width
1267 mm (49.88 in)
• Tabletop film distance
85 mm (3.35 in)
• Tube arm extension distance 300 mm (11.8 in)
• X-ray absorption
< 1.0 mm Al
• Maximum height of X-ray tube
(0.04 in) equivalent
focal spot (vertical position)
• Tabletop travel longitudinal
1100 mm (43.31 in)
• Tabletop travel transverse
240 mm (9.45 in)
Distances from X-ray tube focal spot facing the wall
• Tabletop material
Carbon fiber
stand bucky
• Max. patient weight
350 kg (771 lbs)
• Minimum height
400 mm (15.75 in)
• Bucky travel along table access 51 cm (20.08 in)
• Maximum height
1900 mm (74.8 in)
• Automatic exposure control
3-field solid state
• Column longitudinal motion
2010 mm (79.13 in)
sensors
• Rotation of column with respect
• Grid
1 m (39.37 in)
PATIENT TABLE (ELEVATING)
900 mm (35.43 in)
transverse axis (rotation may be
• Minimum height
500 mm (19.69 in)
limited by cables)
• Vacudap 2004 (external dose area meter)
200 lx
• Additional filtration 1 mm Al + 0.1 mm Cu
INSTALLATION DATA
1 mm Al + 0.2 mm Cu
• Line voltage
2 mm Al or 1 mm Al
(additional transformer required for 80 kW generator
• Rotation
up to maximum
± 90°
2020 mm (79.53 in)
Automatic line compensation
± 10 %
• Power consumption
105 kVA (Gen 64 kW);
• Height
2235 mm (87.99 in)
• Width
620 mm (24.41 in)
• Depth
345 mm (13.58 in)
3-phase, 480 v 60 Hz
below 480 v)
• Radiographic Table
Dimensions
• Ceiling height
120 kVA (Gen 80 kW)
Single phase 110 V~
60 Hz
2.60 - 2.80 m (102.36 -
110.24 in)
(for normal use)
Height from floor to center of active imaging area
• Minimum height 400 mm (15.75 in)
Ambient conditions (operation)
• Maximum height
1900 mm (74.8 in)
Temperature range
+15° C to +30° C
• Bucky vertical motion
1500 mm (59.06 in)
Storage/Transport temperature
-20° C to +70° C
• Surface plane - film distance 44 mm (1.73 in)
Relative humidity (no condensing) 30 % to 75 %
• Radiation absorption < 0.8 mm Al
Atmospheric pressure
± 180°
• Automatic exposure control
± 150°
700 hPA to 1060 hPa
equivalent
3-field solid state
PRODUCT WEIGHTS
sensors
Patient table: non elevating: 190 kg (418.88 lbs)
• Scatter radiation grid
150/180 cm option
Patient table: elevating: 280 kg (617.29 lbs)
(59.06/70.87 in)
Floor mounted tubestand: 345 kg (760.59 lbs)
Wall stand: 145 kg (319.67 lbs)
Assembly with respect to its
• Maximum height
equivalent
WALL STAND
• Rotation of Tube-Collimator
Vertical travel
• Lateral cassette holder 35 x 43
• Full field light localizer
to its vertical axis (rotation may
be limited by cables)
2 mm aluminum SYSTEM ACCESSORIES
• Compression band
From the robust radiographic table, to the wall stand, to
• Hand grips for table
the tubehead and beyond, the DX-D 400 offers high quality,
• Hands support for wall stand
precision hardware for all its components. By improving
uptime and reliability, productivity is increased and reduced
maintenance equals a lower total cost of ownership (TCO)
and better protection of the hospital or clinic’s investment.
2
3
4
DX-D 400
Flexible to meet every need
Services & Support
With its configurations and range of options, the DX-D 400
Agfa HealthCare offers service agreement solutions
will fit with many imaging environments. The Analog
tailored to the individual customer’s situation. The service
Manual configuration includes a radiographic floating
agreements are available in Basic, Advantage and PM Only
fixed-height table and an analog tubehead control panel.
levels, making lifecycle costs predictable.
The Analog Manual (D) version offers an elevating floating
table with a maximum weight limit of 350 kg (771 lbs) and a
digital tubehead control panel.
A worldwide team of some 1,000 service professionals is at
your disposal to provide support at all phases of your project.
As an additional service, they can help you customize your
Both configurations can be enhanced with options such as a
examination tree or link RIS protocol codes for an even
wall stand with a tilting bucky, which provides the operator
higher return on investment. Furthermore, this team carries
with versatility for any type of exam.
out tasks that go well beyond maintenance, including value
added services such as super user training, staff training and
software upgrades.
Floor-mounted suspension: ease of installation and
use
Floor-mounted, the DX-D 400 does not require an expensive
ceiling structure and is quick and easy to install. Its compact
size (4 x 2 m) means it fits into even limited spaces. Yet, with
the touch screen control console (with editable APR, ability
to store new edited studies, functional grouping of controls
and indicators and six selectable patient sizes including three
for children), it still offers complete ease of use. This efficient
design adds to its flexibility.
Solid precision hardware
DX-D 400
DX-D 400
technical
• Lateral cassette holder 24 x 30
COLLIMATORS
• Inherent filtration
S P E C I F I C AT I O N S
PATIENT TABLE (ELEVATING and
NON-ELEVATING)
Dimensions
FLOOR MOUNTED TUBESTAND
• Tubestand longitudinal travel
2 m (optional 3 m)
(78.74 in (optional 118.11 in))
• Height
750 mm (29.53 in)
• Table base length
800 mm (31.5 in)
Tubestand dimensions
• Table base width
2200 mm (86.61 in)
• Height
2370 mm (93.31 in)
• Tabletop width
800 mm (31.5 in)
• Length of base
2755 mm (108.46 in)
• Tabletop length
2200 mm (86.61 in)
• Width
1267 mm (49.88 in)
• Tabletop film distance
85 mm (3.35 in)
• Tube arm extension distance 300 mm (11.8 in)
• X-ray absorption
< 1.0 mm Al
• Maximum height of X-ray tube
(0.04 in) equivalent
focal spot (vertical position)
• Tabletop travel longitudinal
1100 mm (43.31 in)
• Tabletop travel transverse
240 mm (9.45 in)
Distances from X-ray tube focal spot facing the wall
• Tabletop material
Carbon fiber
stand bucky
• Max. patient weight
350 kg (771 lbs)
• Minimum height
400 mm (15.75 in)
• Bucky travel along table access 51 cm (20.08 in)
• Maximum height
1900 mm (74.8 in)
• Automatic exposure control
3-field solid state
• Column longitudinal motion
2010 mm (79.13 in)
sensors
• Rotation of column with respect
• Grid
1 m (39.37 in)
PATIENT TABLE (ELEVATING)
900 mm (35.43 in)
transverse axis (rotation may be
• Minimum height
500 mm (19.69 in)
limited by cables)
• Vacudap 2004 (external dose area meter)
200 lx
• Additional filtration 1 mm Al + 0.1 mm Cu
INSTALLATION DATA
1 mm Al + 0.2 mm Cu
• Line voltage
2 mm Al or 1 mm Al
(additional transformer required for 80 kW generator
• Rotation
up to maximum
± 90°
2020 mm (79.53 in)
Automatic line compensation
± 10 %
• Power consumption
105 kVA (Gen 64 kW);
• Height
2235 mm (87.99 in)
• Width
620 mm (24.41 in)
• Depth
345 mm (13.58 in)
3-phase, 480 v 60 Hz
below 480 v)
• Radiographic Table
Dimensions
• Ceiling height
120 kVA (Gen 80 kW)
Single phase 110 V~
60 Hz
2.60 - 2.80 m (102.36 -
110.24 in)
(for normal use)
Height from floor to center of active imaging area
• Minimum height 400 mm (15.75 in)
Ambient conditions (operation)
• Maximum height
1900 mm (74.8 in)
Temperature range
+15° C to +30° C
• Bucky vertical motion
1500 mm (59.06 in)
Storage/Transport temperature
-20° C to +70° C
• Surface plane - film distance 44 mm (1.73 in)
Relative humidity (no condensing) 30 % to 75 %
• Radiation absorption < 0.8 mm Al
Atmospheric pressure
± 180°
• Automatic exposure control
± 150°
700 hPA to 1060 hPa
equivalent
3-field solid state
PRODUCT WEIGHTS
sensors
Patient table: non elevating: 190 kg (418.88 lbs)
• Scatter radiation grid
150/180 cm option
Patient table: elevating: 280 kg (617.29 lbs)
(59.06/70.87 in)
Floor mounted tubestand: 345 kg (760.59 lbs)
Wall stand: 145 kg (319.67 lbs)
Assembly with respect to its
• Maximum height
equivalent
WALL STAND
• Rotation of Tube-Collimator
Vertical travel
• Lateral cassette holder 35 x 43
• Full field light localizer
to its vertical axis (rotation may
be limited by cables)
2 mm aluminum SYSTEM ACCESSORIES
• Compression band
From the robust radiographic table, to the wall stand, to
• Hand grips for table
the tubehead and beyond, the DX-D 400 offers high quality,
• Hands support for wall stand
precision hardware for all its components. By improving
uptime and reliability, productivity is increased and reduced
maintenance equals a lower total cost of ownership (TCO)
and better protection of the hospital or clinic’s investment.
2
3
4
DX-D 400
GENERATORS
Generator model
DX-D 400
S calable radiography system
Why Agfa HealthCare?
SHF 345
(CR only)
SHF 545
SHF 645
DX-D 400
SHF 845
Agfa HealthCare is a global leader in the fast growing market of integrated IT and imaging systems, offering
healthcare facilities a seamless flow of information and a 360º view of patient care. The company has a unique,
holistic approach, enabling it to provide in-depth clinical know-how and fully integrated hospital-wide solutions.
These specialized solutions integrate IT and imaging systems for Radiology, Cardiology, Mammography and
Orthopaedics. Agfa HealthCare’s enterprise-wide IT platform integrates all administrative and clinical data within a
healthcare facility and is designed to match the unique needs of specific healthcare professionals.
DX-D 400
Input power
3 Phase 480
Max. power (kW) 32
50
64
80
Max. mA
400
640
640
800
Power output @ 0.1s
640 mA @ 78 kVp
640 mA @ 80 kVp
800 mA @ 80 kVp
500 mA @ 100 kVp
640 mA @ 100 kVp
800 mA @ 100 kVp
confidence. The system is floor-mounted and therefore easy
400 mA @ 125 kVp
500 mA @ 128 kVp
640 mA @ 125 kVp
to install, requiring little space and without an expensive
320 mA @ 150 kVp
400 mA @ 150 kVp
500 mA @ 150 kVp
E7252X, E7254FX,
E7254FX, E7869X
Compatible X-ray All
All
Tubes
The DX-D 400 system is a flexible and affordable solution
designed for patient comfort and to enhance radiographer
www.agfahealthcare.com
ceiling structure. The DX-D 400 has adaptable configurations
which can be tailored to the specific needs of your practice.
High quality precision hardware helps maximize uptime -
E7869X
important in a busy imaging environment. The robust table
Range of radiographic parameters
mA
From 10 mA to 800 mA through the following mA stations: 10, 12.5, 16, 20, 25, 32, 40, 50, 64,
80, 100, 125, 160, 200, 250, 320, 400, 500, 640, 800.(Depending on the Generator model)
mAs
Product of mA x time values from 0.1 mAs to 500 mAs
ms
From 1 to 10000 milliseconds through the following time stations: 1, 2, 3, 4, 5, 6, 8, 10, 12, 16,
20, 25, 32, 40, 50, 64, 80, 100, 125, 160, 200, 250, 320, 400, 500, 640, 800, 1000, 1250, 1600,
2000, 2500, 3200, 4000, 5000. 6400, 8000 and 10000.
with floating table top allows for easy positioning. Safety
features, such as double touch foot switches, are built into
the product.
SCALABLE AND AFFORDABLE FLOOR-MOUNTED
RADIOGRAPHY SYSTEM.
AEC (Automatic mAs: 0.1 mAs to 500 mAs exposure time: Nominal shortest irradiation time = 1 ms
Exposure Control)
• Flexible configurations and options
• Floor-mounted for cost-effective and easy
installation and use
• Solid precision components offer reliability and
help maximum uptime • Can be combined with Agfa HealthCare CR systems
for even greater versatility
X-RAY TUBES
5
Housing
Focal spot
Target angle
Heat capacity (kHU)
Anode speed
Toshiba E7884X
0.6 – 1.2
12°
300
Low
Toshiba E7252X
0.6 – 1.2
12°
300
High/Low
Toshiba E7254FX
0.6 – 1.2
12°
400
High/Low
Toshiba E7869X
0.6 – 1.2
12°
600
High/Low
Agfa and the Agfa rhombus are trademarks of Agfa-Gevaert N.V., Belgium, or its affiliates. MUSICA and DX-D are
trademarks of Agfa HealthCare NV, Belgium or its affiliates. All other trademarks are held by their respective
owners and are used in an editorial fashion with no intention of infringement. The data in this publication are
for illustration purposes only and do not necessarily represent standards or specifications, which must be met
by Agfa HealthCare. All information contained herein is intended for guidance purposes only, and characteristics
of the products and services described in this publication can be changed at any time without notice. Products
and services may not be available for your local area. Please contact your local sales representative at agfa.com
for availability information. Agfa HealthCare diligently strives to provide as accurate information as possible, but
shall not be responsible for any typographical error.
© 2011 Agfa HealthCare Corp.
All rights reserved
Published by
Agfa HealthCare Corp.
10 South Academy Street
Greenville, SC 29601 USA
5SJ8D US 00201108
DX-D 400
GENERATORS
Generator model
DX-D 400
S calable radiography system
Why Agfa HealthCare?
SHF 345
(CR only)
SHF 545
SHF 645
DX-D 400
SHF 845
Agfa HealthCare is a global leader in the fast growing market of integrated IT and imaging systems, offering
healthcare facilities a seamless flow of information and a 360º view of patient care. The company has a unique,
holistic approach, enabling it to provide in-depth clinical know-how and fully integrated hospital-wide solutions.
These specialized solutions integrate IT and imaging systems for Radiology, Cardiology, Mammography and
Orthopaedics. Agfa HealthCare’s enterprise-wide IT platform integrates all administrative and clinical data within a
healthcare facility and is designed to match the unique needs of specific healthcare professionals.
DX-D 400
Input power
3 Phase 480
Max. power (kW) 32
50
64
80
Max. mA
400
640
640
800
Power output @ 0.1s
640 mA @ 78 kVp
640 mA @ 80 kVp
800 mA @ 80 kVp
500 mA @ 100 kVp
640 mA @ 100 kVp
800 mA @ 100 kVp
confidence. The system is floor-mounted and therefore easy
400 mA @ 125 kVp
500 mA @ 128 kVp
640 mA @ 125 kVp
to install, requiring little space and without an expensive
320 mA @ 150 kVp
400 mA @ 150 kVp
500 mA @ 150 kVp
E7252X, E7254FX,
E7254FX, E7869X
Compatible X-ray All
All
Tubes
The DX-D 400 system is a flexible and affordable solution
designed for patient comfort and to enhance radiographer
www.agfahealthcare.com
ceiling structure. The DX-D 400 has adaptable configurations
which can be tailored to the specific needs of your practice.
High quality precision hardware helps maximize uptime -
E7869X
important in a busy imaging environment. The robust table
Range of radiographic parameters
mA
From 10 mA to 800 mA through the following mA stations: 10, 12.5, 16, 20, 25, 32, 40, 50, 64,
80, 100, 125, 160, 200, 250, 320, 400, 500, 640, 800.(Depending on the Generator model)
mAs
Product of mA x time values from 0.1 mAs to 500 mAs
ms
From 1 to 10000 milliseconds through the following time stations: 1, 2, 3, 4, 5, 6, 8, 10, 12, 16,
20, 25, 32, 40, 50, 64, 80, 100, 125, 160, 200, 250, 320, 400, 500, 640, 800, 1000, 1250, 1600,
2000, 2500, 3200, 4000, 5000. 6400, 8000 and 10000.
with floating table top allows for easy positioning. Safety
features, such as double touch foot switches, are built into
the product.
SCALABLE AND AFFORDABLE FLOOR-MOUNTED
RADIOGRAPHY SYSTEM.
AEC (Automatic mAs: 0.1 mAs to 500 mAs exposure time: Nominal shortest irradiation time = 1 ms
Exposure Control)
• Flexible configurations and options
• Floor-mounted for cost-effective and easy
installation and use
• Solid precision components offer reliability and
help maximum uptime • Can be combined with Agfa HealthCare CR systems
for even greater versatility
X-RAY TUBES
5
Housing
Focal spot
Target angle
Heat capacity (kHU)
Anode speed
Toshiba E7884X
0.6 – 1.2
12°
300
Low
Toshiba E7252X
0.6 – 1.2
12°
300
High/Low
Toshiba E7254FX
0.6 – 1.2
12°
400
High/Low
Toshiba E7869X
0.6 – 1.2
12°
600
High/Low
Agfa and the Agfa rhombus are trademarks of Agfa-Gevaert N.V., Belgium, or its affiliates. MUSICA and DX-D are
trademarks of Agfa HealthCare NV, Belgium or its affiliates. All other trademarks are held by their respective
owners and are used in an editorial fashion with no intention of infringement. The data in this publication are
for illustration purposes only and do not necessarily represent standards or specifications, which must be met
by Agfa HealthCare. All information contained herein is intended for guidance purposes only, and characteristics
of the products and services described in this publication can be changed at any time without notice. Products
and services may not be available for your local area. Please contact your local sales representative at agfa.com
for availability information. Agfa HealthCare diligently strives to provide as accurate information as possible, but
shall not be responsible for any typographical error.
© 2011 Agfa HealthCare Corp.
All rights reserved
Published by
Agfa HealthCare Corp.
10 South Academy Street
Greenville, SC 29601 USA
5SJ8D US 00201108