PLUS 80t with Perfect Heat™
DELUXE UPFLOW/HORIZONTAL
INDUCED-COMBUSTION FURNACE
330JAV
California Approved
Sizes 060 thru 120
Series C & D
With a unique approach to induced-combustion design, a 40-in.
tall cabinet, a 4-pass heat exchanger, an inshot burner system
and its safety features, this furnace is without peer. The Plus 80t
Upflow/Horizontal Furnace achieves an 80 percent Annual Fuel
Utilization Efficiency (AFUE) rating. The benefits of Perfect Heat
operation in reducing sound and improving comfort put it in a
class well ahead of the competition. The Plus 80t has the kind of
overall performance needed in today’s homes. All models are
GAMA efficiency rating certified and certified for use in California
Air Quality Management Districts.
FEATURES
UPFLOW
HORIZONTAL
EFFICIENCY — The Plus 80t Induced-Combustion Gas Furnace provides the efficiency customers want with 80.0 percent
AFUE.
MEDIA FILTER CABINET — Enhanced indoor air quality in your
home is made easier with our media filter cabinet—a standard
accessory on all deluxe upflow furnaces. When installed as a
part of your system, this cabinet allows for easy and convenient
addition of a Bryant high-efficiency air filter.
HOT SURFACE IGNITION — No pilot to waste gas with this
field-proven ignition system.
ALUMINIZED HEAT EXCHANGER — The patented 4-pass
heat exchanger is made of aluminized steel and backed by a
20-year Limited Warranty.
INTELLIGENT CONTROL — The Plus 80t has an intelligent
control that monitors the operation of the furnace. This control
also has a component-test feature that enables the servicing
technician to verify operation of the control; the high and low inducer; the hot surface ignitor; and high-, medium-, and lowspeed blower operation. The control features a 3-amp fuse that
protects the transformer and control. We guarantee the reliability
of the control with a 3-year Limited Warranty.
40-IN. HEIGHT — The Plus 80t cabinet height is only 40 in. This
simplifies installation in alcoves, attics, basements (ideal for low
basement), closets, and utility rooms, especially with a taller
high-efficiency cooling coil.
PREPAINTED CABINET — The Plus 80t uses prepainted sheet
metal for the cabinet. This is the same high-quality finish found
on refrigerators and other appliances today. We ensure its durability by using a galvanized steel substrate to provide superior
rust protection.
PATENTED BLOCKED VENT — Our induced-combustion furnace has a patented blocked vent safeguard. The switch will stop
furnace operation if the vent system becomes blocked or is not
operating properly. An exclusive with the Plus 80t furnace.
EASY INSTALLATION — The Plus 80t has many features that
make installation easier: left or right gas and electrical connections, heating and cooling blower speed selector, matching coil
sizes, accessory low-voltage connections, and many more. Certified for use in California Air Quality Management Districts.
QUIET OPERATION — A soft mount inducer assembly and 2stage slow-opening gas valve reduce sound level. The two
stages of heating capability minimizes furnace and air noise for
total home comfort.
PDS 330J.60.7
28 1⁄2˝
2 1⁄16˝
VENT CONN
5 3⁄ 8˝
12 5⁄16˝
2 11⁄16˝
5 13⁄16˝
5 13⁄16˝
2 3⁄8˝
1 3⁄4-IN. DIA HOLE
GAS ENTRY
HOLE
THERMOSTAT
WIRE ENTRY
7⁄8-IN.
DIA
POWER ENTRY
1 1⁄2-IN. DIA
R.H. GAS ENTRY
7⁄8-IN. DIA
ACCESSORY
1⁄2-IN. DIA THERMOSTAT
WIRE ENTRY
2 3⁄8˝
1⁄2-IN. DIA
13⁄16˝
OUTLET
1˝
5 3⁄8˝
HOLE
POWER ENTRY
7⁄8-IN. DIA
ACCESSORY
19˝
13⁄16˝
1˝
7⁄8-IN. DIA
39 7⁄8˝
2 1⁄16˝
A
D
SIDE INLET (FOR UPFLOW
INSTALLATION ONLY)
SIDE INLET (FOR UPFLOW
INSTALLATION ONLY)
141⁄2˝
TYP 1˝
11⁄4˝
11⁄16˝
24 5⁄16˝
3˝
11⁄16˝
AIR INLET
DIMPLES TO DRILL HOLES FOR HANGER BOLTS:
8 PLACES (FOR HORIZONTAL INSTALLATIONS ONLY)
E
11⁄16˝
5⁄8˝
TYP
1˝
231⁄4˝
SIDE RETURN
DUCT LOCATION
NOTES: 1. Two additional 7⁄8-in. dia holes are located in the top plate.
2. Minimum return-air openings at furnace, based on metal duct. If flex duct is used,
see flex duct manufacturer's recommendations for equivalent diameters.
AIRFLOW
a. For 800 CFM–16-in. round or 141⁄2 x 12-in. rectangle.
b. For 1200 CFM–20-in. round or 141⁄2 x 191⁄2-in. rectangle.
c. For 1600 CFM–22-in. round or 141⁄2 x 231⁄4-in. rectangle.
d. For airflow requirements above 1800 CFM, see Air Delivery table in Product Data literature for specific
use of single side inlets. The use of both side inlets, a combination of 1 side and the bottom, or the
bottom only will ensure adequate return air openings for airflow requirements above 1800 CFM.
A00358
DIMENSIONS (In.)
E
VENT
CONN (Dia)*
SHIPPING
WEIGHT
(Lb)
MEDIA CABINET
SUPPLIED
12-9/16
12-11/16
4
134
16''
19-3/8
19-1/2
4
154
20''
21
19-3/8
19-1/2
4
166
20''
060100
24-1/2
22-7/8
23
4
184
24''
060120
24-1/2
22-7/8
23
5†
194
24''
UNIT
SIZE
A
D
036060
14-3/16
048080
21
048100
* Refer to the furnace Installation Instructions for proper venting procedures.
† Oval collar
—2—
MINIMUM INCHES CLEARANCE TO COMBUSTIBLE CONSTRUCTION
This furnace is approved for UPFLOW and HORIZONTAL
installations.
Clearance arrows
do not change with
furnace orientation.
An accessory kit, supplied by the manufacturer, shall
be used to convert to propane gas use or may be
required for some natural gas applications.
This furnace is for indoor installation in a building
constructed on site.
0"
BA
This furnace may be installed on combustible flooring
in alcove or closet at minimum clearance from
combustible material.
FU
S
(362mm) may be 0 inches.
For Type B-1 vent 3 inches.
E
ID
*#
T
ON
FR
FR
ON
* 1" #
T
RV
IC
E
30"
##
MIN
BOTTO
Ø
Clearance in inches.
Vent Clearance to combustibles:
For Single Wall vents 6 inches.
For Type B-1 vent 1 inch.
322291-101 REV. J
Ø 18 inches front clearance required for alcove.
# # For single wall vent 6 inches.
E
†
*
Indicates supply or return sides when furnace is in
the horizontal position. Line contact only permissible
between lines formed by intersections of the Top
and two Sides of the furnace jacket, and building
joists, studs or framing.
AC
1"
#
†
RN
DE
SI T È
CÔ
SE
# For horizontal furnaces wider than 14.25 inches
For upflow furnaces bottom clearance may be
0 inches.
1"
CK
M
This furnace may be used with a Type B-1 Vent and
may be vented in common with other gas-fired
appliances.
1"
TOP / PLENUM
This forced air furnace is equipped for use with natural
gas at altitudes 0-5,500 ft. (0-1,675 m) above sea
level. The high-altitude conversion kit MUST be
installed above 5,500 ft (1,675 m). See the furnace
installation instructions for high altitude gas input
derating requirements.
A00298
CONTROLS—THERMOSTATS AND ZONING
THERMOSTAT—NON-PROGRAMMABLE
Auto Changeover, °F/°C, 1-Stage Heat/1-Stage Cool —TSTATBBNAC01-B
Auto Changeover, °F/°C, 2-Stage Heat/1-Stage Cool —TSTATBBNHP01-B
Auto Changeover, °F/°C, 2-Stage Heat/2-Stage Cool —TSTATBBN2S01-B
in AC Mode, 3-Stage Heat/2-Stage Cool in HP Mode
Air Conditioner, 1-Stage Heat/1-Stage Cool. Manual Changeover, °F/°C —TSTATBBBAC01
Heat Pump, 2-Stage Heat/1-Stage Cool. Manual Changeover, °F/°C —TSTATBBBHP01*
THERMOSTAT—PROGRAMMABLE
Auto Changeover, 7-Day Programmable, °F/°C, 1-Stage Heat/1-Stage Cool —TSTATBBPAC01-B
Auto Changeover, 7-Day Programmable, °F/°C, 2-Stage Heat/1-Stage Cool —TSTATBBPHP01-B
Auto Changeover, 7-Day Programmable, °F/°C, —TSTATBBP2S01-B
2-Stage Heat/2-Stage Cool in AC Mode, 3-Stage Heat/2-Stage Cool in HP Mode
Dual Fuel Thermostat. Includes Outdoor Air Temperature Sensor —TSTATBBPDF01-B*
Thermidistat™ Control — Non-Programmable/Programmable —TSTATBBPRH01-B*
Thermostat with Humidity Control (For use in Dual Fuel, AC, HP, and 2S applications.
Includes Outdoor Air Temperature Sensor.)
ZONING—2-ZONE
ZONEBB2KIT01, ZONEKIT2ZBDP
ZONING—4-ZONE
ZONEBB4KIT01
ZONING—8-ZONE
ZONEBB8KIT01
* Do not use in zoning heat pump applications.
—3—
SPECIFICATIONS
UNIT SIZE
036060
048080
048100
060100
060120
RATINGS AND PERFORMANCE
Gas Input (Btuh)*
High Stage
60,000
80,000
100,000
100,000
117,000
Low Stage
39,000
52,000
65,000
65,000
78,000
Output Capacity (Btuh)†
High Stage
48,000
65,000
81,000
81,000
95,000
Nonweatherized ICS
Low Stage
31,000
42,000
53,000
53,000
63,000
80.0
80.0
80.0
80.0
80.0
25—55
30—60
40—70
25—55
40—70
AFUE%†
Nonweatherized ICS
Certified Temperature Rise
High Stage
Range (°F)
Low Stage
15—45
15—45
20—50
15—45
25—55
Heat/Cool
0.12/0.50
0.15/0.50
0.20/0.50
0.20/0.50
0.20/0.50
Heating High/Low
1170/1000
1445/1260
1410/1265
1800/1460
1775/1500
1195
1740
1575
2250
2025
Certified External Static Pressure
Airflow CFM‡
Cooling
ELECTRICAL
Unit Volts— Hertz— Phase
115—60—1
Operating Voltage Range
104—127
Maximum Unit Amps
Maximum Wire Length (Measured 1 Way)
Ft
10.6
13.4
13.2
17.7
18.2
34
27
28
32
31
Minimum Wire Size
14
14
12
12
Maximum Fuse or Ckt Bkr Size‡‡
15
15
20
20
Transformer (24v)
40va
External Control
Heating
19va
Power Available
Cooling
35va
Air Conditioning Blower Relay
Standard
CONTROLS
Limit Control
SPST (Auto-Reset)
Heating Blower Control
Solid-State Time Operation
Inducer
2-Speed
Burners (Monoport)
3
4
5
Gas Connection Size
6
1/2-in. NPT
GAS CONTROLS
2-Stage Redundant Gas Valve
White-Rodgers
Min Inlet Pressure (In. wc)
4.5 (Natural Gas)
Max Inlet Pressure (In. wc)
13.6 (Natural Gas)
Ignition Device
Hot Surface
BLOWER DATA
Direct-Drive Motor HP (PSC)
1/3
1/2
1/2
3/4
3/4
Motor Full Load Amps
5.1
7.4
7.9
11.0
11.1
1075—4
1075—5
1075—4
1075—5
1075—4
10 x 6
10 x 8
10 x 8
11 x 10
11 x 10
(1) 16 x 25 x 1
(1) 20 x 25 x 1
(1) 20x 25 x 1
(1) 24 x 25 x 1
(1) 24 x 25 x 1
RPM (Nominal)—Speeds
Blower Wheel Diameter x Width (In.)
Filter Size (In.)—Permanent Washable (Supplied)
FACTORY-AUTHORIZED DEALER-INSTALLED ACCESSORIES
Twinning Kit
N/A
KGATW0301HSI
High-Altitude Pressure Switch Kit**
KGAHA5501PSW
Gas Conversion Kit—Natural-to-Propane††
KGANP26012SP
Gas Conversion Kit—Propane-to-Natural††
KGAPN21012SP
Bryant Media Filter (2 pack)
FILBBFTC0016
FILBBFTC0020
FILBBFTC0024
* Gas input ratings are certified for elevations to 2000 ft. For elevations above 2000 ft, reduce ratings 4 percent for each 1000 ft above sea level. Refer to
National Fuel Gas Code Table F4 or furnace Installation Instructions. In Canada, derate the unit 10 percent for elevations 2000 ft to 4500 ft above sea level.
† Capacity in accordance with U.S. Government DOE test procedures.
‡ • Airflow shown is for bottom only return-air supply with factory-supplied 1-in. washable filter(s).
• For air delivery above 1800 CFM, see Air Delivery table for other options.
• An airflow reduction of up to 7% may occur when using the factory-specified 4 5/16-inch wide, high efficiency media filter. See filter media product data
for exact pressure drop data.
• For best furnace efficiency when using the 4 5/16-inch wide media filter, adjust the blower speed tap to near the mid-point of the rise range.
** 5500 ft and higher above sea level.
†† Factory-authorized and field installed. Gas conversion kits are C.S.A. (A.G.A. and C.G.A.) approved.
‡‡ Time-delay type is recommended.
ICS—Isolated Combustion System
N/A—Not Applicable
—4—
AIR DELIVERY— CFM (With Filter)*
UNIT
SIZE
036060
048080
048100
RETURN-AIR
SUPPLY
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
High
1430
1380
1325
1265
1195
1125
1045
945
Med-High
1170
1150
1135
1105
1055
995
925
845
Med
1000
1000
990
970
935
885
835
750
Med-Low
865
870
855
840
815
780
720
655
Low
685
690
680
665
645
610
570
500
High
2010
1950
1875
1810
1740
1660
1550
1455
Med-High
1675
1660
1625
1600
1545
1490
1395
1295
Med
1445
1430
1415
1400
1370
1325
1265
1170
Med-Low
1260
1260
1260
1250
1210
1180
1115
1030
Low
950
985
985
970
950
915
845
740
High
1880
1815
1745
1690
1575
1500
1400
1265
Bottom
Med-High
1660
1615
1570
1505
1435
1355
1260
1170
or 1 Side
Med-Low
1455
1410
1375
1350
1290
1235
1145
985
Low
1265
1265
1240
1210
1180
1110
995
855
High
2485
2480
2405
2330
2250
2155
2025
1905
Med-High
2165
2135
2105
2055
1995
1915
1830
1735
Med
1785
1800
1785
1760
1725
1665
1600
1490
Med-Low
1465
1460
1470
1460
1425
1385
1330
1255
Low
1220
1215
1210
1195
1180
1150
1095
1020
Both Sides or
High
—
2465
2420
2355
2265
2165
2065
1940
1 Side and Bottom
Med-High
2145
2145
2135
2090
2025
1955
1870
1780
High
2410
2345
2275
2185
2095
1995
1875
1760
Med-High
2140
2100
2050
1985
1920
1835
1740
1635
Bottom
or 1 Side
Bottom
or 1 Side
Bottom
Only
060100
1 Side Only
060120
EXTERNAL STATIC PRESSURE (IN. WC)
SPEED
High
—
2260
2185
2085
2025
1935
1835
1730
Bottom
Med-High
2110
2070
2015
1960
1885
1810
1715
1620
Only
Med-Low
1790
1775
1755
1720
1670
1610
1535
1455
Low
1495
1500
1515
1485
1450
1400
1345
1270
Both Sides or
High
2425
2360
2275
2195
2095
2010
1890
1775
1 Side and Bottom
Med-High
2055
2035
1995
1945
1880
1810
1735
1640
High
2245
2175
2070
1980
1900
1805
1695
1575
Med-High
2050
1985
1925
1850
1765
1690
1585
1480
1 Side Only
* Side return to be used for upflow applications only. A filter is required for each return-air supply opening.
— Indicates unstable operating conditions.
Airflow shown is with factory supplied 1-in. washable filter(s). An airflow reduction of up to 7% may occur when using the 4 5/16-inch wide, high-efficiency
media filter. For best furnace efficiency when using the 4 5/16-inch wide media filter, adjust the blower speed tap to near the mid-point of the rise range.
—5—
MEDIA FILTER CABINET
25 5/8"
23 5/8"
24 3/8"
Opening with Flanges Bent
23 3/8"
23 1/8"
Opening
B Opening
A
Furnace Side
Duct Side
23 3/4"
Centerline Screw Slots
5 3/4"
Media/
Filter Cabinet
A
B
16"
17
16"
20"
21
20"
24"
25
24"
A00309
ama
CERTIFIED
MEETS DOE RESIDENTIAL
CONSERVATION SERVICES
PROGRAM STANDARDS.
REGISTERED
QUALITY SYSTEM
Before purchasing this appliance,
read important energy cost and
efficiency information available
from your retailer.
—6—
—7—
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE
UNIT MUST BE INSTALLED IN ACCORDANCE
WITH INSTALLATION INSTRUCTIONS
Cancels: PDS 330J.60.6
© 1999 Bryant Heating & Cooling Systems, 7310 W. Morris St.
Indpls., IN 46231
—8—
PRINTED IN U.S.A.
Catalog No. 5233-009
10-00