ClearOne - XAP800 - Extron Electronics

IP Link® Device Interface
Communication Sheet
clr1_25_2178_7.pke
Revision: 2/28/2013
This document provides additional assistance with wiring your Extron IP Link enabled product to your device.
Different components may require a different wiring scheme than those listed below.
For complete operating instructions, refer to the user's manual for the specific Extron IP Link enabled product or
the controlled device manufacturer supplied documentation.
Device Specifications:
Device Type:
Manufacturer:
Firmware Version:
Model(s):
Audio Processor
ClearOne
2.5.0
XAP800
Version History:
Driver
Version
Date
IP Link
Compiler
GC
Version
Notes
7
2/15/2013
1.5.1
3.3.2
Modify feedback parsing.
6
01/10/2013
1.5.1
3.3.2
Updated driver to most current A/V conference standards.
5
11/11/2010
1.4.0
3.0.4
Extron Certified. Tested on XAP800. Added input mute, output
mute, process mute, microphone mute, and line mutes and their
status. Updated driver to current standards.
4
6/14/10
1.4.0
3.0.3
Extron Certified. No functionality changes. Revised comm sheet.
3
06/12/07
1.3.11.1
2.2.1
Extron Certified. tested on XAP800. Added Macro Recall, Bus
Gain, Bus Gain Up/Down
2
04/17/06
1.0.9.3
2.1
Extron Certified, tested on XAP800
1
05/20/05
1.0.9.3
1.6
Extron Certified, tested on XAP800
Driver Notes:
 Default Device ID is set to 0.
 For MLC62 control, ClearOne Device ID must be set to 0.
 This driver includes Volume Optimization.
 Flow control must be set to “Off” on the ClearOne XAP800 unit
Page 1 of 4
IP Link® Device Interface
Communication Sheet
clr1_25_2178_7.pke
Control Commands & States:
Device ID
0–7
Fader 1 - 4 Level
-65 to 20 in steps of 1
Input 1-12 Level
-65 to 20 in steps of 1
Input 1-12 Level (Step)
Up
Macro
1 – 255
Master Mute
On
Mic 1-8 (Discrete)
-65 to 20 in steps of 1
Mic 1 - 8 (Step)
Up
Down
Mic 1 - 8 Mute
On
Off
Mute Fader 1 - 4
On
Off
Mute Input 1-12
On
Off
Mute Output 1 – 12
On
Off
Mute Process A - H
On
Off
Output 1 - 12 Level
-65 to 20 in steps of 1
Output 1 – 12 Level (Step)
Up
Preset
1–8
Process A - H Level
-65 to 20 in steps of 1
Process A - H Level (Step)
Up
All
Down
Off
Down
Down
Page 2 of 4
Revision: 2/28/2013
IP Link® Device Interface
Communication Sheet
clr1_25_2178_7.pke
Status Available:
Connection Status
Connected
Disconnected
Fader 1 - 4 Level
-65 to 20 in steps of 1
Input 1-12 Level
-65 to 20 in steps of 1
Master Mute
On
Mic 1-8 (Discrete)
-65 to 20 in steps of 1
Mic 1 - 8 Mute
On
Off
Mute Fader 1 - 4
On
Off
Mute Input 1-12
On
Off
Mute Output 1 - 12
On
Off
Mute Process A - H
On
Off
Output 1 - 12 Level
-65 to 20 in steps of 1
Process A - H Level
-65 to 20 in steps of 1
Off
MLC60 Series Supported Commands:
Input 1 - 12 Level (Step)
Up
Down
Macro
1 – 255
Master Mute
On
Off
Mic 1-8 Mute
On
Off
Mic 1-8 (Step)
Up
Down
Mute Fader 1-4
On
Off
Mute Input 1 – 12
On
Off
Mute Output 1 – 12
On
Off
Mute Process A – H
On
Off
Output 1 - 12 Level (Step)
Up
Down
Preset
1 – 32
Process A - H Level (Step)
Up
Down
Page 3 of 4
Revision: 2/28/2013
clr1_25_2178_7.pke
IP Link® Device Interface
Communication Sheet
Revision: 2/28/2013
Cable and Adapter Requirements:
M/F RS-232 Straight Cable (Extron Electronics P/N 26-433-XX)
Notes for the Device:
Serial communication:
Port Type: RS-232
Baud Rate: 38400
Data Bits: 8
Parity: None
Stop Bits: 1
Flow Control: None
Pin Assignments Diagram:
Note: Captive screw connector may also be used as a serial connection. It may be necessary to short pins 7 and 8