- Home
- Domestic appliances
- Climate control
- Split-system air conditioners
- Samsung
- AJ009JNADCH/AA
- Installation manual
Samsung AJ009JNADCH/AA FJM Series 9 MBH Wall Mount Indoor Mini-Split Single-Zone Installation manual
Add to my manuals
21 Pages
The Samsung AJ009JNADCH/AA air conditioner offers powerful and efficient cooling for rooms up to 90 square meters. With its advanced features, you can enjoy a comfortable and convenient indoor climate all year round. Experience fast cooling and even distribution of air throughout your space, thanks to the unit's 4-way swing and auto-swing functions. Stay in control with the wireless remote and set your desired temperature and fan speed with ease.
advertisement
▼
Scroll to page 2
of 21
Contents Safety precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 Choosing the installation location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 Fixing the installation plate. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 Disassembling/Assembling the Cover panel for indoor unit installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 Connecting the wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 Installing and connecting the assembly pipe of the indoor unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Evacuating the indoor unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Cutting or extending the pipe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Installing and connecting the condensate drain hose to indoor unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Changing drain connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Installing the indoor unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Final check and trial operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 How to extend the power wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Sub PCB installation(optional) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Safety precautions Carefully follow the precautions listed below because they are essential to guarantee the safety of the equipment. t"MXBZTEJTDPOOFDUUIFBJSDPOEJUJPOFSGSPNUIFQPXFSTVQQMZCFGPSFTFSWJDJOHJUPSBDDFTTJOHJUTJOUFSOBMDPNQPOFOUT t7FSJGZUIBUJOTUBMMBUJPOBOEUFTUJOHPQFSBUJPOTBSFQFSGPSNFECZRVBMJGJFEQFSTPOOFM t7FSJGZUIBUUIFBJSDPOEJUJPOFSJTOPUJOTUBMMFEJOBOFBTJMZBDDFTTJCMFBSFB General information X Carefully read the content of this manual before installing the air conditioner and store the manual in a safe place in order to be able to use it as reference after installation. X For maximum safety, installers should always carefully read the following warnings. X 4UPSFUIFPQFSBUJPOBOEJOTUBMMBUJPONBOVBMJOBTBGFMPDBUJPOBOESFNFNCFSUPIBOEJUPWFSUPUIFOFXPXOFSJGUIFBJS conditioner is sold or transferred. X 5IJTNBOVBMFYQMBJOTIPXUPJOTUBMMBOJOEPPSVOJUXJUIBTQMJUTZTUFNXJUIUXP4".46/(VOJUT 5IFVTFPGPUIFSUZQFTPGVOJUTXJUIEJòFSFOUDPOUSPMTZTUFNTNBZEBNBHFUIFVOJUTBOEJOWBMJEBUFUIFXBSSBOUZ The manufacturer shall not be responsible for damages arising from the use of non compliant units. X The manufacturer shall not be responsible for damage originating from unauthorized changes or the improper connection PGFMFDUSJDBOESFRVJSFNFOUTTFUGPSUIJOUIFi0QFSBUJOHMJNJUTwUBCMFJODMVEFEJOUIFNBOVBMTIBMMJNNFEJBUFMZJOWBMJEBUF the warranty. X The air conditioner should be used only for the applications for which it has been designed: the indoor unit is not suitable to be installed in areas used for laundry. X Do not use the units if damaged. If problems occur, switch the unit off and disconnect it from the power supply. X In order to help QSFWFOUFMFDUSJDTIPDLTöSFTPSJOKVSJFTBMXBZTTUPQUIFVOJUEJTBCMFUIFQSPUFDUJPOTXJUDIBOEDPOUBDU 4".46/(TUFDIOJDBMTVQQPSUJGUIFVOJUQSPEVDFTTNPLFJGUIFQPXFSDBCMFJTIPUPSEBNBHFEPSJGUIFVOJUJTWFSZOPJTZ X "MXBZTSFNFNCFSUPJOTQFDUUIFVOJUFMFDUSJDDPOOFDUJPOTSFGSJHFSBOUUVCFTBOEQSPUFDUJPOTSFHVMBSMZ5IFTFPQFSBUJPOT TIPVMECFQFSGPSNFECZRVBMJöFEQFSTPOOFMPOMZ X 5IFVOJUDPOUBJOTNPWJOHQBSUTXIJDITIPVMEBMXBZTCFLFQUPVUPGUIFSFBDIPGDIJMESFO English-2 X POPUBUUFNQUUPSFQBJSNPWFBMUFSPSSFJOTUBMMUIFVOJU*GQFSGPSNFECZVOBVUIPSJ[FEQFSTPOOFMUIFTFPQFSBUJPOTNBZ % DBVTFFMFDUSJDTIPDLTPSöSFT X %POPUQMBDFDPOUBJOFSTXJUIMJRVJETPSPUIFSPCKFDUTPOUIFVOJU X "MMUIFNBUFSJBMTVTFEGPSUIFNBOVGBDUVSFBOEQBDLBHJOHPGUIFBJSDPOEJUJPOFSBSFSFDZDMBCMF X 5IFQBDLJOHNBUFSJBMBOEFYIBVTUCBUUFSJFTPGUIFSFNPUFDPOUSPMMFSPQUJPOBM NVTUCFEJTQPTFEPGJOBDDPSEBODFXJUI current laws. X 5IFBJSDPOEJUJPOFSDPOUBJOTBSFGSJHFSBOUUIBUIBTUPCFEJTQPTFEPGBTTQFDJBMXBTUF"UUIFFOEPGJUTMJGFDZDMFUIFBJS conditioner must be disposed of in authorized centers or returned to the retailer so that it can be disposed of correctly and safely. Installing the unit *.1035"/58IFOJOTUBMMJOHUIFVOJUBMXBZTSFNFNCFSUPDPOOFDUöSTUUIFSFGSJHFSBOUUVCFTUIFOUIFFMFDUSJDBMMJOFT "MXBZTEJTBTTFNCMFUIFFMFDUSJDMJOFTCFGPSFUIFSFGSJHFSBOUUVCFT X 6QPOSFDFJQUJOTQFDUUIFQSPEVDUUPWFSJGZUIBUJUIBTOPUCFFOEBNBHFEEVSJOHUSBOTQPSU *GUIFQSPEVDUBQQFBSTEBNBHFE%0/05*/45"--JUBOEJNNFEJBUFMZSFQPSUUIFEBNBHFUPUIFDBSSJFSPSSFUBJMFSJGUIF JOTUBMMFSPSUIFBVUIPSJ[FEUFDIOJDJBOIBTDPMMFDUFEUIFNBUFSJBMGSPNUIFSFUBJMFS X "GUFSDPNQMFUJOHUIFJOTUBMMBUJPOBMXBZTDBSSZPVUBGVODUJPOBMUFTUBOEQSPWJEFUIFJOTUSVDUJPOTPOIPXUPPQFSBUFUIFBJS conditioner to the user. X %POPUVTFUIFBJSDPOEJUJPOFSJOFOWJSPONFOUTXJUIIB[BSEPVTTVCTUBODFTPSDMPTFUPFRVJQNFOUUIBUSFMFBTFGSFFøBNFTUP BWPJEUIFPDDVSSFODFPGöSFTFYQMPTJPOTPSJOKVSJFT X To help QSFWFOUJOKVSZXIFOBDDJEFOUBMMZUPVDIJOHUIFJOEPPSVOJUGBOJOTUBMMUIFJOEPPSVOJUBUMFBTU̓NBCPWFUIFøPPS X The air conditioner should be used only for the applications for which it has been designed : the indoor unit is not suitable to be installed in areas used for laundry. X Our units must be installed in compliance with the spaces indicated in the installation manual to ensure either accessibility GSPNCPUITJEFTPSBCJMJUZUPQFSGPSNSPVUJOFNBJOUFOBODFBOESFQBJST5IFVOJUTDPNQPOFOUTNVTUCFBDDFTTJCMFBOEUIBU can be disassembled in conditions of complete safety either for people or things. 'PSUIJTSFBTPOXIFSFJUJTOPUPCTFSWFEBTJOEJDBUFEJOUPUIF*OTUBMMBUJPO.BOVBMUIFDPTUOFDFTTBSZUPSFBDIBOESFQBJSUIF VOJUJOTBGFUZBTSFRVJSFECZDVSSFOUSFHVMBUJPOTJOGPSDF XJUITMJOHTUSVDLTTDBòPMEJOHPSBOZPUIFSNFBOTPGFMFWBUJPO XPOUCFDPOTJEFSFEJOXBSSBOUZBOEDIBSHFEUPFOEVTFS Power supply line, fuse or circuit breaker X "MXBZTNBLFTVSFUIBUUIFQPXFSTVQQMZJTDPNQMJBOUXJUIDVSSFOUTBGFUZTUBOEBSET"MXBZTJOTUBMMUIFBJSDPOEJUJPOFSJO compliance with current local safety standards. X "MXBZTWFSJGZUIBUBTVJUBCMFHSPVOEJOHDPOOFDUJPOJTBWBJMBCMF X 7FSJGZUIBUUIFWPMUBHFBOEGSFRVFODZPGUIFQPXFSTVQQMZDPNQMZXJUIUIFTQFDJöDBUJPOTBOEUIBUUIFJOTUBMMFEQPXFSJT sufficient to ensure the operation of any other domestic appliance connected to the same electric lines. X "MXBZTWFSJGZUIBUUIFDVUPòBOEQSPUFDUJPOTXJUDIFTBSFTVJUBCMZEJNFOTJPOFE X 7FSJGZUIBUUIFBJSDPOEJUJPOFSJTDPOOFDUFEUPUIFQPXFSTVQQMZJOBDDPSEBODFXJUIUIFJOTUSVDUJPOTQSPWJEFEJOUIFXJSJOH diagram included in the manual. X "MXBZTWFSJGZUIBUFMFDUSJDDPOOFDUJPOTDBCMFFOUSZTFDUJPOPGMFBETQSPUFDUJPOTy BSFDPNQMJBOUXJUIUIFFMFDUSJD TQFDJöDBUJPOTBOEXJUIUIFJOTUSVDUJPOTQSPWJEFEJOUIFXJSJOHTDIFNF "MXBZTWFSJGZUIBUBMMDPOOFDUJPOTDPNQMZXJUIUIFTUBOEBSETBQQMJDBCMFUPUIFJOTUBMMBUJPOPGBJSDPOEJUJPOFST X 6TF$PQQFS4VQQMZ8JSFT English-3 Choosing the installation location Indoor unit X X X X X X X X X 8IFSFBJSøPXJTOPUCMPDLFE 8IFSFDPPMBJSDBOCFEJTUSJCVUFEUISPVHIPVUUIFSPPN Install the refrigerant piping length and the height difference of both indoor and outdoor units as indicated in the installation diagram. 8BMMUIBUQSFWFOUTWJCSBUJPOBOEJTTUSPOHFOPVHIUPIPMEUIFQSPEVDUXFJHIU Out of the direct sunlight . N PSNPSFBXBZGSPNUIF57PSSBEJPUPQSFWFOUUIFTDSFFOGSPNCFJOHEJTUPSUFEPSOPJTFGSPNCFJOHHFOFSBUFE "TGBSBXBZBTQPTTJCMFGSPNUIFøVPSFTDFOUBOEJODBOEFTDFOUMJHIUTTPUIBUUIFSFNPUFDPOUSPMMFSDBOCFPQFSBUFEXFMM "QMBDFXIFSFUIFBJSöMUFSDBOCFSFQMBDFEFBTJMZ %POhUJOTUBMMEJSFDUMZBCPWFFMFDUSPOJDTFRVJQNFOUBTMFBLJOHXBUFSNBZDBVTFEBNBHFJGOPUTFSWJDFEFH$PNQVUFST57FUD JODINN PSNPSF JODINN or more 8SBQUIFSFGSJHFSBOUQJQFTBOEUIFESBJOIPTF XJUIUIFBCTPSCFOUQBEBOEWJOZMUBQF3FGFSUP QBHFGPSGVSUIFSEFUBJMT JODINN or more You can select the direction of ESBJOJOHMFGUPSSJHIU h-hNBTNBYJNVNQJQFMFOHUIBOE GUN BTNJOJNVNQJQFMFOHUI *UXJMMSFEVDFOPJTFBOEWJCSBUJPO 'H' meters maximum total pipe height h-hNFUFSTNBYJNVNUPUBMQJQF length Model L H AJ02077 AJ02477 GUN GUN GUN GUN .BLFBUMFBTUPOFSPVOE*UXJMMIFMQSFEVDFOPJTFBOEWJCSBUJPO KThe appearance of the unit may be different from the diagram depending on the model. English-4 Accessories The following accessories are supplied with the air conditioner: t 5IFOVNCFSPGFBDIBDDFTTPSZJTJOEJDBUFEJOQBSFOUIFTFT *OTUBMMBUJPO1MBUF *OTUBMMBUJPO1MBUF 7777 GSBNF 7777 GSBNF 3FNPUFDPOUSPMMFS #BUUFSJFTGPS3FNPUF DPOUSPMMFS 6TFST.BOVBM *OTUBMMBUJPO.BOVBM $BQ4DSFXT $BTF4VC1$# Tools required for installation General Tools t7BDVVN1VNQ#BDLXBSEøPXJOHQSFWFOUJPO t5PSRVF8SFODI t1JQF$VUUFS t3FBNFS t4DSFX%SJWFS t4QBOOFS t%SJMM t.BOJGPME(BVHF t1JQF#FOEFS t-8SFODI Tools for test operations t5IFSNPNFUFS t3FTJTUBODF.FUFS t&MFDUSPTDPQF English-5 t4UVE'JOEFS t4QJSJU-FWFM t.FBTVSJOH5BQF 01 INSTALLATION Accessories in the indoor unit case Fixing the installation plate :PVDBOTFMFDUUIFEJSFDUJPOPGUIFESBJOIPTFEFQFOEJOHPOXIFSFZPVXBOUUPJOTUBMMUIFJOEPPSVOJU5IFSFGPSFCFGPSFöYJOH UIFJOTUBMMBUJPOQMBUFUPBXBMMPSBXJOEPXGSBNFZPVNVTUEFUFSNJOFUIFQPTJUJPOPGUIFJODI̓NN IPMFUISPVHIXIJDI the cable, pipe and hose pass to connect the indoor unit to the outdoor unit. 8IFOGBDJOHUIFXBMMUIFQJQFBOEDBCMFDBOCFDPOOFDUFEGSPNUIF t3JHIU" t-FGU# t6OEFSTJEF@SJHIU$ t3FBS@SJHIUPSMFGU% K Direction of pipe B A D D C 1. Disassemble the cover panel as described in page 7~8. 2. Remove the Hanger plate from the indoor unit. 6OTDSFXTDSFXTUIBUöYFTUIF)BOHFSQMBUFUPUIFJOEPPSVOJU 1VTIUIFIPPLTPOUIFCPUUPNQBSUPGUIFJOEPPSVOJU VQUPSFMFBTFUIFJOTUBMMBUJPOQMBUFGSPNUIFIPPLTUIBUIPMETJU 1VMMUIFJOTUBMMBUJPOQMBUFUPSFMFBTFJUDPNQMFUFMZGSPNUIFJOEPPSVOJU Screw 3. Determine the position of the pipe and drain hose hole as seen in the picture and drill the hole with an inner diameter of 2.56inch(65 mm) so that it slants slightly downwards. B D D A 1JQFIPMF<JODINN > A 1JQFIPMF<JODINN > B C C <6OJUJODINN ] Model A B C 7777 7777 D t . BLFTVSFUPESJMMPOMZPOFIPMFBGUFSDIPPTJOH the direction of the pipe. 4. Fix the indoor unit. If you fix the indoor unit on a wall 'JYUIFJOTUBMMBUJPOQMBUFUPUIFXBMMHJWJOHBUUFOUJPOUPUIFXFJHIUPGUIFJOEPPSVOJU t *GZPVNPVOUUIFQMBUFUPBDPODSFUFXBMMVTJOHQMBTUJDBODIPSTNBLFTVSFUIBU HBQTCFUXFFOUIFXBMMBOEUIFQMBUFDSFBUFECZQSPKFDUFEBODIPSJTMFTTUIBO JODI̓NN 1MBTUJD "ODIPS If you fix the indoor unit on a window frame %FUFSNJOFUIFQPTJUJPOTPGUIFXPPEFOVQSJHIUTUPCFBUUBDIFEUPUIFXJOEPXGSBNF "UUBDIUIFXPPEFOVQSJHIUTUPUIFXJOEPXGSBNFHJWJOHBUUFOUJPOUPUIFXFJHIUPGUIFJOEPPSVOJU "UUBDIUIFJOTUBMMBUJPOQMBUFUPUIFXPPEFOVQSJHIUVTJOHUBQQJOHTDSFXT If you fix the indoor unit on a gypsum board 6TFTUVEöOEFSUPöOEPVUMPDBUJPOTPGUIFTUVET 'JYUIFQMBUFIBOHFSPOUXPTUVET English-6 JODI ̓NN 8BMM t 4 FBSDIGPSPUIFSTQPUTJGUIFSFBSFMFTTUIBOUXPTUVETPSUIFEJTUBODFCFUXFFOUIFTUVETBSFEJòFSFOUGSPNUIF plate hanger. t 'JYUIFJOTUBMMBUJPOQMBUFXJUIPVUJODMJOJOHUPPOFTJEF Assembling the hanger screw 6TFTDSFXTUPöYUIFJOEPPSVOJUXJUIIBOHFSQMBUFBTTIPXO in the picture. Screw Disassembling/Assembling the Cover panel for indoor unit installation Please scan this QR code for detail video of indoor unit installation. In order to install the indoor unit, you must disassemble the cover panel first. Please proceed following instructions to disassemble and assemble the cover panel. Hooks (on the cover panel) may get damaged if you apply excessive force as you disassemble and assemble the cover panel. Please follow the following instructions. Removing the screws Cover panel is assembled on the bottom part of the indoor unit (as shown in the illustration) and it is fastened with screws. Remove the Cap screw first and unfasten the screws so that you can disassemble the cover panel. Cap Screw <Remove the Cap screw> Cover Panel <Unfasten the screw> English-7 01 INSTALLATION t .BLFTVSFUIBUBXBMMDBOXJUITUBOEUIFXFJHIUPGUIFQSPEVDU*GZPVJOTUBMMUIFQSPEVDUJOBQMBDFXIFSFJUJTOPU TUSPOHFOPVHIUPXJUITUBOEUIFQSPEVDUXFJHIUUIFVOJUDPVMEGBMMBOEDBVTFJOKVSZ Disassembling/Assembling the Cover panel for indoor unit installation Removing the Cover panel (Before mounting the indoor unit) The bottom panel fits the main body using the side, center, and bottom hooks as shown. Unlock the side hooks first, and then unlock the center and bottom hooks. Check the location of the hooks before removing the cover panel. fLocation of the hooks on the central part Number and location of the hooks Side hooks Center hook Bottom hook Center hooks Bottom hooks fRemoving the hooks on the side ② N For specific Hook location and quantity, please refer to cover panel with indicating arrows based on physical goods. fRemoving the hooks on the central part ① N Caution (fragile) - Gently press the both side of the cover panel inwards (①) and release the hooks on both sides(②). N Caution (fragile) - Use both hands - Release each hook by pushing it up at an angle. Assembling the Cover panel (After mounting the indoor unit) To assemble the Cover panel, proceed in reverse order of disassembling. Use both hands for assembling and be extra careful not to damage the pipes and drain hose. Lock the side, center, and bottom hooks in this sequence. Tighten the bottom panel with the screws, and close the screw holes with their cap. <Lock the side hook> <Lock the bottom hook> <Fasten the screw> <Assemble the Cap screw> English-8 Connecting the wiring If using a multi system, install as described in the installation manual supplied with the outdoor unit. Cable specification Power cable 7777 (NN¤)3/' 7777 (NN¤)3/' Interconnection cable Type GL (NN¤)3/' YNN¤)3/' (NN¤)3/' YNN¤)3/' " " t $ POOFDUUIFQPXFSDBCMFUPUIFBVYJMJBSZDJSDVJUCSFBLFS*GFWFSZQPMFGBJMTUPDPOOFDUUPUIFQPXFS supply, it must be incorporated in a wire with a contact opening of ≥JODINN t 6 TFTIJFMEDBCMF$BUFHPSZMFTTUIBOQ'N GPSOPJTZFOWJSPONFOUBMTJUF t 1PXFSTVQQMZDPSETPGQBSUTPGBQQMJBODFTGPSPVUEPPSVTFTIBMMOPUCFMJHIUFSUIBOQPMZDIMPSPQSFOF TIFBUIFEøFYJCMFDPSE$PEFEFTJHOBUJPO*&$*&$$&/&-&$)3/'*&$*&$ $&/&-&$)3/' Connecting the cable Electrical work 'PSFMFDUSJDBMBOEFBSUIXPSLTDPNQMZXJUIUIFAUFDIOJDBMTUBOEBSETPGFMFDUSJDBMJOTUBMMBUJPOTBOEUIFUIFAXJSJOH SFHVMBUJPOTPGUIF-PDBMXJSJOHSFHVMBUJPOT 5JHIUFOUIFUFSNJOBMCMPDLTDSFXUPVOEFSGUtlb[/tNLHGtDN . 1SFDBVUJPOTXIFODPOOFDUJOHUFSNJOBMCMPDLTPGUIFJOEPPSVOJU X #FGPSFDPOOFDUJOHNBLFTVSFUIFDPOOFDUJOHQBSUPGUIFUFSNJOBMTPDLFUJTGBDJOHVQXBSET 6QTJEFEPXO X The terminal TPDLFUJTEBNBHFE There is no ring UFSNJOBMUPDPWFSUIFXJSF There must be no space between the terminal and the screw when connected. "OZSFNBJOJOHTQBDFNBZCFDPNFBöSFIB[BSEEVFUPPWFSIFBUJOHPGUIFFMFDUSJDBMDPOUBDU 5IFUFSNJOBMTPDLFU is upside down. &JUIFSUIFTDSFXJTOPUGJUUFE properly or there is a space between the screw and the ring terminal. t ' PSUIFUFSNJOBMCMPDLXJSJOHVTFBXJSFXJUIBSJOHUFSNJOBMTPDLFUPOMZ 3FHVMBSXJSFTXJUIPVUBSJOHUFSNJOBMTPDLFUNBZCFDPNFBöSFIB[BSEEVFUPPWFSIFBUJOHPGUIFFMFDUSJDBMDPOUBDUEVSJOH BXJSJOHXPSL K8IFOZPVJOTUBMMUIFVOJUNBLFöSTUSFGSJHFSBOUDPOOFDUJPOTBOEUIFOFMFDUSJDBMDPOOFDUJPOT Connect the air conditioner to grounding system before performing the electrical connection. *GVOJUJTVOJOTUBMMFEöSTUEJTDPOOFDUFMFDUSJDBMDBCMFTUIFOSFGSJHFSBOUDPOOFDUJPOT *GUIFPVUEPPSVOJUJTNPSFUIBOGUN BXBZGSPNUIFJOEPPSVOJUZPVNVTUFYUFOEUIFDBCMF5IFNBYJNVNMFOHUIPGUIF cable is GUN 7777 98.4fUN 7777 1. Extend the assembly cable if necessary. t % POPUDPOOFDUUXPPSNPSFEJòFSFOUDBCMFTUPFYUFOEUIFMFOHUI *UNBZDBVTFöSF English-9 01 INSTALLATION Model Connecting the wiring 2 . Open the cover panel. 3 . Remove the screw securing the connector cover. 4 . Pass the assembly cable through the rear of the indoor unit and connect the assembly cable to terminals. (Refer to the picture below) t &BDIXJSFJTMBCFMFEXJUIUIFDPSSFTQPOEJOHUFSNJOBMOVNCFS 5. 6. 7. 8. 9. Pass the other end of the cable through the 2.56inch(65 mm) hole in the wall. Close the connector cover by tightening the screw carefully. Close the cover panel. Remove the terminal board cover on the side of the outdoor unit. Connect the cables to the terminals as seen in the picture. t & BDIXJSFJTMBCFMFEXJUIUIFDPSSFTQPOEJOHUFSNJOBMOVNCFS Indoor unit L1 L2 F1 F2 L1 L2 F1 F2 Indoor unit .BJO1PXFS Supply cable Outdoor unit 1PXFSDBCMFUP indoor units Outdoor unit F1 F2 F1 F2 L1 L2 L1 L2 L1 L2 1 2 A t "MTPDJSDVMBSUFSNJOBMNVTUCFNBUDIFEXJUITDSFXTJ[FJOUFSNJOBMCMPDL t "GUFSDPOOFDUJOHUIFDBCMFTNBLFTVSFUFSNJOBMOVNCFSTPOUIFJOEPPSPVUEPPSVOJUNBUDIFT t 1MFBTFFOTVSFUIBU1PXFS$PNNVOJDBUJPODBCMFTBSFTFQBSBUFEUIFZNVTUOPUCFJOUIFTBNFDBCMF 10. Connect the grounding conductor to the grounding terminals. 11. Close the terminal board cover by tightening the screw carefully. t *O3VTTJBBOE&VSPQFDPOTVMUXJUIUIFTVQQMZBVUIPSJUZUPEFUFSNJOFUIFTVQQMZTZTUFNJNQFEBODFCFGPSF installation. t $ POOFDUUIFXJSFTöSNMZTPUIBUXJSFTDBOOPUCFQVMMFEPVUFBTJMZ *GUIFZBSFMPPTFJUDPVMEDBVTFCVSOPVUPGUIFXJSFT t $ POOFDUUIFXJSFTBDDPSEJOHUPDPMPSDPEFTSFGFSSJOHUPUIFXJSJOHEJBHSBN t 5IFQPXFSDBCMFBOEUIFJOUFSDPOOFDUJPODBCMFTIPVMECFTFMFDUFEBDDPSEJOHUPUIFTQFDJöDBUJPOJOQBHF English-10 Installing and connecting the assembly pipe of the indoor unit 5IFSFBSFSFGSJHFSBOUQJQFTPGEJòFSFOUEJBNFUFST t5IFTNBMMFSPOFJTGPSUIFMJRVJESFGSJHFSBOU t5IFMBSHFSPOFJTGPSUIFHBTSFGSJHFSBOU "TIPSUQJQFJTBMSFBEZöUUFEUPUIFBJSDPOEJUJPOFS:PVNBZ OFFEUPFYUFOEUIFQJQFVTJOHUIFBTTFNCMZQJQFPQUJPOBM 5IFDPOOFDUJPOQSPDFEVSFGPSUIFSFGSJHFSBOUQJQFWBSJFT according to the exit position of the pipe when facing the wall: t3JHIU" t-FGU# t6OEFSTJEF$ t3FBS B A 1. Cut out the appropriate knock-out piece (A, B, C) on the rear of the indoor unit unless you connect the pipe directly from the rear. 2. Smooth the cut edges. 3. Remove the protection caps of the pipes and connect the assembly pipe to each pipe. Tighten the nuts first with your hands, and then with a torque wrench, applying the following torque: C Torque Outer Diameter øJODI øNN øJODI øNN øJODI NN øJODI øNN t *GZPVXBOUUPTIPSUFOPSFYUFOEUIFQJQFTSFGFSUPQBHF_ 4. Cut off the remaining foam insulation. 5. If necessary, bend the pipe to fit along the bottom of the indoor unit. Then pull it out through the appropriate hole. X 5IFQJQFTIPVMEOPUQSPKFDUGSPNUIFSFBSPGUIFJOEPPSVOJU X 5IFCFOEJOHSBEJVTTIPVMECFJODINN PSNPSF 6. Pass the pipe through the hole in the wall. t 5 JHIUFOUIFøBSFOVUXJUIUPSRVFXSFODIBDDPSEJOHUPTQFDJöFENFUIPE *GUIFøBSFOVUJTPWFSUJHIUFOFEUIFøBSFNBZCSFBLBOEDBVTFSFGSJHFSBOUHBTMFBLBHF t %0/058"--615)&1*1&$0//&$5*0/ "MMSFGSJHFSBOUQJQFDPOOFDUJPONVTUCFFBTZBDDFTTJCMFBOETFSWJDFBCMF English-11 /tN _ _ _ _ fUtMC LHGtDN _ _ _ _ _ _ _ _ 01 INSTALLATION $POOFDUJOEPPSBOEPVUEPPSVOJUTXJUIöFMETVQQMJFEDPQQFSQJQFTCZNFBOTPGøBSFDPOOFDUJPOT6TFJOTVMBUFETFBNMFTT SFGSJHFSBUJPOHSBEFQJQFPOMZ$V%)1UZQFBDDPSEJOHUP*40 EFHSFBTFEBOEEFPYJEJ[FETVJUBCMFGPSPQFSBUJOHQSFTTVSFT PGBUMFBTUL1BBOEGPSCVSTUQSFTTVSFPGBUMFBTUL1B6OEFSOPDJSDVNTUBODFTNVTUTBOJUBSZUZQFDPQQFSQJQFCF used. Evacuating the indoor unit 5IFJOEPPSVOJUJTTVQQMJFEXJUIJOFSUHBTOJUSPHFO #FGPSFJOTUBMMJOHUIFVOJUDIFDLJGOJUSPHFOHBTøPXPVUPGJOEPPSVOJU *GUIJTPOFJTOUUSVF%0/05*/45"--5)&6/*5TJODFMFBLBHFDPVMECFJOTJEFUIFJOEPPSVOJU 1. Unscrew the caps at the end of each pipe. X "MMJOFSUHBTFYIBVTUTGSPNUIFJOEPPSVOJU t 5 PQSFWFOUEJSUPSGPSFJHOTVCTUBODFTGSPNHFUUJOHJOUPUIFQJQFTEVSJOH JOTUBMMBUJPOEP/05SFNPWFUIFDBQTDPNQMFUFMZVOUJMZPVBSFSFBEZUP connect the pipes. t 5 IFSFNBJOJOHBJSJOUIF3FGSJHFSBUJPODZDMFXIJDIDPOUBJOTNPJTUVSF may cause malfunction on the compressor. t "MXBZTDPOUBDUUIFTFSWJDFDFOUFSPSBQSPGFTTJPOBMJOTUBMMBUJPOBHFODZ for product installation. 1JQFT 6OTDSFXUIF caps Cutting or extending the pipe The length of the pipe can be: t&YUFOEFEVQUPTFFUBCMFQBHF t4IPSUFOVQUPTFFQBHF *GZPVOFFEBQJQFMPOHFSUIBOGUNFUFST t :PVNVTUBEESFGSJHFSBOUUPUIFQJQFTPUIFSXJTFUIFJOEPPSVOJUNBZGSFF[F 1. Make sure that you have all the required tools (pipe cutter, reamer, flaring tool and pipe holder). 2. If you want to shorten the pipe, cut it using a pipe cutter, ensuring that the cut edge remains at 90° with the side of the pipe (see below examples of correct and incorrect cut edges). 1JQF cutter Oblique 3PVHI Burr 1JQF 3. To prevent a gas leak, remove all burrs at the cut edge of the pipe using a reamer. t 'BDFUIFQJQFEPXOXIJMFSFNPWJOHUIFCVSSTUPNBLFTVSFUIBUCVSSTEPOPUHFUJOUPUIFQJQF English-12 4. Put a flare nut slightly into the pipe and modify the flare. 90°± 2° 45e ±2e R 0.4~0.8 1JQF Flare Depth (A) Flaring Size (B) øJODI NN JODI NN inch NN øJODI NN JODI NN inch NN øJODI NN JODI NN inch NN øJODI NN JODI NN inch NN 5. Check if you flared the pipe correctly (see examples of incorrectly flared pipes below). Correct Inclined Damaged Surface $SBDLFE 6OFWFO 5IJDLOFTT 6. Align the pipes to connect them easily. Tighten the flare nuts first with your hands, and then with a torque wrench, applying the following torque: Flare nut Indoor outlet pipe Connecting pipe Outer Diameter øJODIøNN øJODIøNN øJODINN øJODIøNN /tN _ _ _ _ Torque fUtMCLHGtDN __ __ __ __ t &YDFTTJWFUPSRVFDBOCFDBVTFPGHBTMFBLBHF*GFYUFOEJOHQJQFCZXFMEJOHCSB[JOHQMFBTFFOTVSFOJUSPHFOJTVTFE EVSJOHXFMEJOHCSB[JOHQSPDFTT5IFKPJOUNVTUCFBDDFTTJCMFBOETFSWJDFBCMF 7. For further details on how to connect to the outdoor unit and evacuate the air, refer to the installation manual supplied with the outdoor unit. t 5JHIUFOUIFøBSFOVUXJUIUPSRVFXSFODIBDDPSEJOHUPTQFDJöFENFUIPE *GUIFøBSFOVUJTPWFSUJHIUFOFEUIFøBSFNBZCSFBLBOEDBVTFSFGSJHFSBOUHBTMFBLBHF English-13 01 INSTALLATION B Outer Diameter (D) Installing and connecting the condensate drain hose to indoor unit 8IFOJOTUBMMJOHUIFESBJOIPTFGPSUIFJOEPPSVOJUDIFDLJGDPOEFOTBUJPOESBJOJOHJTBEFRVBUF 8IFOQBTTJOHUIFESBJOIPTFUISPVHIUIFNN IPMFESJMMFEJOUIFXBMMDIFDLUIFGPMMPXJOHT 8BMM Indoor unit Drain hose 5IFESBJOIPTFNVTU/05 slant upwards. DN less The end of the drain hose NVTU/05CFQMBDFEVOEFS water. The drain hose must not be bent. "GUFSDPNQMFUJOHUIF installation of the drain hose, pour water into UIFESBJOQBOUPDIFDL whether the hose is well drained. Ditch Keep a clearance of at least Do not place the end of the ̓DNCFUXFFOUIFFOEPGUIF drain hose in a hollow. drain hose and the ground. *ODPSSFDUDPOOFDUJPO $PSSFDUDPOOFDUJPO Drain hose 1JQF Drain hose 1JQF t %POUUJFESBJOIPTFUPUIFBTTFNCMZQJQFXIJDINBZMFBEUPXBUFSMFBLBHF Drain hose installation *GOFDFTTBSZDPOOFDUUIFGUN FYUFOTJPOESBJOIPTFUPUIFESBJOIPTF *GZPVVTFUIFFYUFOTJPOESBJOIPTFJOTVMBUFUIFJOTJEFPGUIFFYUFOTJPOESBJOIPTFXJUIBTIJFME 'JUUIFESBJOIPTFJOUPPGESBJOIPTFIPMFTUIFOöYUIFFOEPGUIFESBJOIPTFUJHIUMZXJUIBDMBNQ t *GZPVEPOPUVTFUIFPUIFSESBJOIPTFIPMF CMPDLJUXJUIBSVCCFSTUPQQFS 4. 8IFOFYUFOEJOHUIF%SBJO)PTFIPMEUIFFOEPG%SBJO)PTFBOE&YUFOEFE)PTF SPUBUFBOEJOTFSUUIFESBJOIPTFJOUP&YUFOEFEIPTFGPS_JODI_ NN .BLFTVSFUIFUXPIPTFTBSFöSNMZDPOOFDUFEUIFSFJTOPXBUFSMFBLBHF Drain hose hole $POOFDUUIF%SBJO)PTFBGUFSVTJOH'PBN*OTVMBUJPOUPXSBQUIF&YUFOEFE)PTF5IFO6TFWJOZMUBQFUPXSBQUIF each side of connection by JnchNN English-14 _Jnch _NN Drain hose &YUFOTJPO drain hose 1BTTUIFESBJOIPTFVOEFSUIFSFGSJHFSBOUQJQFLFFQJOHUIFESBJOIPTFUJHIU Shield 1BTTUIFESBJOIPTFUISPVHIUIFIPMFJOUIFXBMM$IFDLJGJUTMBOUT downwards as seen in the picture. 6TJOHOBUVSBMESBJOBHFNFUIPEDIFDLUIFESBJOBHFJTOPSNBM Drain hose Foam Insulation 7JOZM5BQF &YUFOTJPOESBJOIPTF t 5IFIPTFXJMMCFöYFEQFSNBOFOUMZJOUPQPTJUJPOBGUFSöOJTIJOHUIFJOTUBMMBUJPOBOEUIFHBTMFBLUFTU t . BLFTVSFUIFJOTUBMMFEEJSFDUJPOPGUIFESBJOIPTFJTDPSSFDU *OBEFRVBUFJOTUBMMBUJPONBZDBVTFDPOEFOTBUFXBUFSMFBLBHF t *GUIFESBJOIPTFJTSPVUFEJOTJEFUIFSPPNJOTVMBUFUIFIPTFTPUIBUESJQQJOHDPOEFOTBUJPOEPFTOPUEBNBHFUIF GVSOJUVSFPSøPPST t %0/058"--615)&%3"*/)04&$0//&$5*0/ %SBJOIPTFDPOOFDUJPONVTUCFFBTZBDDFTTJCMFBOETFSWJDFBCMF Changing drain connection Change the direction only when it is necessary. Screw hole Screw 1. Detach the rubber cap with the pliers. 2. Detach the drain hose by pulling it and turning to the left. 3. Insert the drain hose by fixing it with the screw into the groove of the drain hose and the outlet of the drain pan. 4. Attach the rubber cap with a screwdriver by turning it to the right until it fixes to the end of the groove. 5. Check for leakage on both side of the drain outlet. 1PVSUIFXBUFSJOEJSFDUJPOPGBSSPX KDirection of the drained water t . BLFTVSFUIFJOEPPSVOJUJTJOVQSJHIUQPTJUJPOXIFOZPVQPVSXBUFSUPDIFDLGPSMFBLBHF .BLFTVSFUIBUUIFXBUFSEPFTOPUPWFSøPXPOUPUIFFMFDUSJDBMQBSU English-15 Drain hose Drain pan outlet 3VCCFSDBQ 01 INSTALLATION Drain hose &YUFOTJPO drain hose JODI JODI NN NN or more or more Installing the indoor unit 1FSGPSNUIFGPMMPXJOHXPSLPOUIFBSFBXIFSFHBTMFBLUFTUXBTEPOFQSJPSZ "GUFSDIFDLJOHGPSHBTMFBLTJOUIFTZTUFNJOTVMBUFUIFQJQFIPTFBOEDBCMFT Then place the indoor unit on the installation plate. Insulation 1. To minimise condensation problems, wrap foam insulation (as shown in the figure) on a part without insulation on the end of the pipes. 2. Wind the pipe, assembly cable and drain hose with vinyl tape. 3. Place the bundle (the pipe, assembly cable and drain hose) in the lower part of the indoor unit carefully so it does not project from the rear of the indoor unit. 4. Hook the indoor unit to the installation plate and move the unit to the right and left until it is securely in place. 1JQFT Installation plate 7JOZMUBQF Connecting wires t . BLFTVSFQJQFEPFTOPUNPWFXIFOZPVJOTUBMMUIFJOEPPSVOJUPO an installation plate. 5. Wrap the rest of the pipe with vinyl tape. 6. Attach the pipe to the wall using clamps (optional). English-16 Drain hose Connecting pipes Final check and trial operation 5PDPNQMFUFUIFJOTUBMMBUJPOQFSGPSNUIFGPMMPXJOHDIFDLTBOEUFTUTUP ensure that the air conditioner operates correctly. 1. Press the Power 01 INSTALLATION Check the followings: t4USFOHUIPGUIFJOTUBMMBUJPOTJUF t5JHIUOFTTPGQJQFDPOOFDUJPOUPEFUFDUHBTMFBL t&MFDUSJDXJSJOHDPOOFDUJPO t)FBUSFTJTUBOUJOTVMBUJPOPGUIFQJQF t%SBJOBHF t(SPVOEJOHDPOOFDUJPO t$PSSFDUPQFSBUJPOGPMMPXUIFTUFQTCFMPX button and check the following: X The indicator on the indoor unit lights up. X 5IFBJSøPXCMBEFPQFOTBOEUIFGBOHFBSTVQGPSPQFSBUJPO 2. Press the Mode button to select Cool or Heat mode. X X In Cool mode, use Temp hr. + or –CVUUPOBOETFUUIFUFNQFSBUVSFBU̓¡$o' In Heat mode, use Temp hr. + or –CVUUPOBOETFUUIFUFNQFSBUVSFBU̓¡$o' t " QQSPYJNBUFMZ_NJOVUFTMBUFSPVUEPPSVOJUXJMMTUBSUUPPQFSBUFBOEUIF $PPMPS8BSNBJSXJMMCMPXPVU t "GUFSNJOVUFTPGTUBUJPOBSZDPOEJUJPODIFDLUIFJOEPPSVOJUBJSUSFBUNFOU $PPMJOHNPEFJOEPPSVOJUDIFDL ­*OMFUBJSUFNQ0VUMFUBJSUFNQ 'SPN̓¡'UP̓¡'JOEJDBUJWFEFMUB5 )FBUJOHNPEFJOEPPSVOJUDIFDL ­0VUMFUBJSUFNQ*OMFUBJSUFNQ 'SPN̓¡'UP¡'JOEJDBUJWFEFMUB5 *OIFBUJOHNPEFUIFJOEPPSGBONPUPSDBOSFNBJOPòUPQSFWFOUDPMEBJSCFJOHCMPXOJO to conditioned space. 3. Press the Air swing button and check the following: X 5IFBJSøPXCMBEFTXPSLQSPQFSMZ 4. Press the Power button to stop the operation. t 8 IFOZPVDPNQMFUFUIFJOTUBMMBUJPOTVDDFTTGVMMZIBOEPWFSUIJTNBOVBMUPUIFVTFSGPSTUPSBHFJOBIBOEZBOETBGF place. English-17 How to extend the power wiring Items to prepare DPNQSFTTPSBOEJOTVMBUJPOUBQFTIPVMECFQSFQBSFECZBOJOTUBMMBUJPOUFDIOJDJBO Tools Spec Crimping pliers $POOFDUJPOTMFFWFNN Insulation tape $POUSBDUJPOUVCFNN .) YJODI YNN )Y0% 8JEUI JODINN YJODI YNN -Y0% Shape 1. As shown in the figure, peel off the shields from the rubber/wire of the power cable. - Peel off 20 mm of the wire shields of the tube installed already. t "GUFSQFFMJOHPòUIFUVCFXJSFZPVNVTUJOTFSUBDPOUSBDUJPOUVCF 6OJUJODINN 1PXFSDBCMFQSPWJEFECZVT 20 0.79(20) 20 0.79(20) 20 0.79(20) 60 2.36(60) 120 4.72(120) 180 7.09(180) 8JSFUVCFQPXFSDBCMF 20 0.79(20) 2. Insert both sides of core wire of the power cable into the connection sleeve. $POOFDUJPOTMFFWF 3. Using a compressor, compress the two points and flip it over and compress another two points in the same location. - The compression dimension should be 8.0. - After compressing it, pull both sides of the wire to make sure it is firmly pressed. Comp. dim. Compress it 4 times JODINN 4. Wrap it with the insulation tape twice and position your contraction tube in the middle of the insulation tape. 5. Apply heat to the contraction tube to contract it. Insulation tape JODINN Contraction tube 6. After tube contraction work is completed, wrap it with the insulation tape to finish. t *ODBTFPGFYUFOEJOHUIFFMFDUSJDXJSFQMFBTF%0/05VTFBSPVOETIBQFEQSFTTJOHTPDLFU *ODPNQMFUFXJSFDPOOFDUJPOTDBODBVTFFMFDUSJDTIPDLPSBöSF English-18 Insulation tape Sub PCB installation(optional) 8JSFESFNPUFDPOUSPMMFSDFOUSBMSFNPUFDPOUSPMMFSFUD 01 INSTALLATION 1. Turn the power off and take off the cover panel of the indoor unit. 2. Attach the Sub PCB to the Case Sub PCB. 3. Assemble the Case Sub PCB to the indoor unit. 1(L) 2(N) F1 F2 $BTF4VC1$# 4VC1$# 4. Find the PCB wire, and connect the wire to the Sub PCB as seen in the picture. 1(L) 2(N) F1 F2 5. Connect the wire(remote controller, central remote controller etc) to the Sub PCB. 1(L) 2(N) F1 F2 6. Assemble the Cover PCB and the front panel. ❋ If the Sub PCB is not installed, arrange the wire for multi system (connection) as shown in the illustration. 1(L) 2(N) Wire for multi system connection t 5 IF4VC1$#JTBUUBDIFEUPCFDPOUSPMMFECZUIFXJSFESFNPUFDPOUSPMMFSBOEDFOUSBMDPOUSPMMFS English-19 F1 F2 AR FSSSBWK Series AR FSSSCUR Series AJ777JNADCH Series Air Conditioner userinstallation & installation manual manual This manual is made with 100% recycled paper. imagine the possibilities Thank you for purchasing this Samsung product. To receive more complete service, please register your product at www.samsung.com/register EN ES FR DB68-04993A-00
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement