LT-100 CONE LIGHTING SYSTEM FOR MATRIX FAMILY READERS

PACKAGE CONTENTS
POSITIONING Matrix-1000/2000™
The LT-100 package contains the following items:
LT-100 CONE
LIGHTING SYSTEM
FOR MATRIX FAMILY READERS
LT-100 Cone Lighting System
Matrix-1000/2000™ Mounting bracket
(4) M2.5 screws for bracket mounting to cone
(4) M4 screws for bracket mounting to reader
(4+4) M2.5 locking and flat washers for bracket mounting to reader
Instruction Manual
MOUNTING Matrix-1000/2000™
β=99 mm
α
code surface
B
Focus distance = α + β
DESCRIPTION
The LT-100 Cone Lighting System provides a circular symmetrical light
source designed for the following applications:
with uneven or noisy background surfaces. By using LT-100 these
disturbances are suppressed and the code is highlighted.
A
where dot peening or laser etching codes are directly marked onto
metal surfaces or PCBs and need to be highlighted.
in the presence of highly reflective surfaces (metal, glass, etc.)
causing direct reflections.
MECHANICAL DIMENSIONS
1. Mount the bracket A onto the LT-100 Cone B using the 4 M2.5
screws in the package.
2. Mount the reader onto the lighting cone assembly aligning it to the
correct holes according to the Focus Distance of the model used.
See "Positioning" in the Matrix Reference Manual. Use the 4 M4
screws and washers in the package.
140.0
[5.51]
3. Wire the LT-100 to the CBX according to the Wiring table on the
opposite page.
mm
[inch]
4. Position the Matrix assembly over the code reading area at the
correct Focus Distance for your model, (described in the Matrix
Reference Manual under "Reading Features").
58.1
[2.29]
NOTE
Alternatively, the accessory BK-510 bracket can be
used to mount Matrix-1000/2000™ to the LT-100
Cone. This bracket provides slots to increase
positioning possibilities.
The best results for this illuminator are obtained when α is
approximately 20 mm (0.8"). However other Reading Distances
(described in the Matrix Reference Manual) can be used. You can
maximize the reading performance through VisiSet™.
MOUNTING Matrix 400™
5.
Remove the Lens Cover and loosen the Locking Knobs as
described in the Reference Manual. Swing the bracket D 90°
returning to the reading position.
6.
Position and mount the Matrix assembly over the code reading
area at the correct Focus Distance (or range) for your model,
(described in the Matrix Reference Manual).
7.
Perform the Focusing procedure described in the Reference
Manual.
8.
After Focusing, tighten the Focus and Diaphragm Locking Knobs.
Swing the bracket D 90° as previously shown to replace the Lens
Cover. Swing the bracket D 90° returning to the reading position
and fix the reader assembly (C+D) to the illuminator assembly
(A+B) with the remaining 2 M4 screws from the bag marked
"Screws for Bracket-Bracket-Reader assembling".
The following parts are required for mounting:
LT-100 Cone Lighting System
BK-4990 Matrix 400™ Generic LT Bracket
C
D
POSITIONING Matrix 400™
TECHNICAL FEATURES
Supply Voltage
Power Consumption
Optimal Working Distance
Effective Working Range
Illumination Area
Wavelength
Max. LED Output Power
Typical Irradiance
Operating Temperature
Dimensions (D x H)
Weight
10 to 30 Vdc
1.5 to 0.5 A; 15 W max.
20 mm (0.8")
12.7 - 50 mm (0.5" - 2")
Ø 90 mm @ 20 mm
(Ø 3.5" @ 0.8")
630 nm
0.2 mW to EN60825-1
10 W/m² @ 20 mm
0 – 40 °C
140 x 58 mm (5.5" x 2.3")
(without bracket)
305 g. (without bracket)
COMPLIANCE
A
LED Class
40 mm
Class 1 LED Product to EN 60825-1:(2001)
Power Supply
This product is intended to be connected to a UL Listed Direct Plug-in Power Unit
marked LPS or “Class 2”, rated 10 to 30 V, minimum 1.5 A.
CE Compliance
B
Warning: This is a Class A product. In a domestic environment this product may
cause radio interference in which case the user may be required to take adequate
measures.
code surface
Focus distance = α + β
1.
The BK-4990 bracket comes already partially mounted (D+A) with
2 M4 screws.
2.
Mount the bracket A onto the LT-100 Cone B using the 4 M2.5
screws in the bag marked "Screws for Brackets-LT-100/LT-300
assembling".
3.
Swing the bracket D 90° and mount the reader C onto it through
the mounting holes on the bracket. Use 4 of the M4 screws in the
bag marked "Screws for Bracket-Bracket-Reader assembling".
4.
Wire the LT-100 to the CBX according to the following Wiring table.
FCC Compliance
The best results for this illuminator are obtained when α is
approximately 20 mm (0.8"). However other Reading Distances
(described in the Matrix Reference Manual) can be used. You can
maximize the reading performance through VisiSet™.
Modifications or changes to this equipment without the expressed written approval
of Datalogic could void the authority to use the equipment.
WIRING
This equipment has been tested and found to comply with the limits for a Class A
digital device, pursuant to part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference when the equipment is
operated in a commercial environment. This equipment generates, uses, and can
radiate radio frequency energy and, if not installed and used in accordance with
the instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful
interference in which case the user will be required to correct the interference at
his own expense.
Wire Color
Red
Black
Blue
White
CAUTION
CBX/Matrix Signal
Vdc
GND
O1-, O2-, (O3-)
O1+, O2+, (O3+)
Meaning
10 to 30 Vdc
Ground
Control Signal Control Signal +
The LT-100 control signals must always be
connected to one of the Matrix Digital Output
signals. In VisiSet™, set the relative Output Line
Function parameter to "External Lighting System" and
the Matrix Output x External Lighting System Mode
parameter to "Triggered".
This device complies with PART 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference which
may cause undesired operation.
821000893 (Rev. G)