Ventilation Technical Data Control box for air handling applications EEDEN15-205 EKEQ • Accessory • EKEQ TABLE OF CONTENTS EKEQ 1 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 2 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 3 3 Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 4 Control systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 5 Combination table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 6 Dimensional drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 7 Wiring diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Wiring Diagrams - Single Phase 8 • Ventilation • EKEQ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 External connection diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 1 • Accessory • EKEQ 1 Wide range of units offers maximum application potential and flexible control options • Both option kits are designed for indoor and outdoor installation and can be wall mounted. • The system provides optimized air conditions such as fresh air and humidity control etc. and can be used in small warehouses, showrooms and offices. • • Control box and expansion valve kit are required for each combination plus an air handling unit Wide offer in control possibilities: control x: room, suction or discharge temperature can be controlled via DDC control (field supplied); control y: control by fixed evaporating temperature; control z: room or suction temperature control via Daikin remote control; remote ON/OFF can be achieved by an optional adapter KRP4A51 t x o a b l y r l i o o st r s tn eQ n cE e oKc •AEVC 1 2 Features • Ventilation • EKEQ • Accessory • EKEQ 2 Specifications 2-1 Technical Specifications EKEQDCB Application Pair Outdoor unit Dimensions Height Packing Casing mm 3 VRV 132 Width mm 400 Depth mm 200 Height mm 215 Width mm 495 Depth mm 310 2 Unit kg 3.6 3.9 3.6 Packed unit kg 4.6 4.9 4.6 Material Carton / EPS / Plastic Colour White grey Material Operation range EKEQMCBA Multi ERQ Unit Packed unit Weight EKEQFCBA Resin Cooling Min. °CDB -10 Max. °CDB 40 On coil temperature Heating Min. °CDB - Cooling Max. °CDB - Standard Accessories : Stopper (closing up); Quantity : 0; Standard Accessories : Wire to wire splice; Quantity : 6; Standard Accessories : Thermistor (R2T/R3T); Quantity : 2; Standard Accessories : Capacity setting adapter; Quantity : 7; Standard Accessories : Insulation sheet; Quantity : 2; Standard Accessories : Rubber sheet; Quantity : 2; Standard Accessories : Installation and operation manual; Quantity : 1; Standard Accessories : Screw nut; Quantity : 8; Standard Accessories : Tie-wraps; Quantity : 6; Standard Accessories : Thermistor (R1T); Quantity : 1; 2-2 Electrical Specifications Power supply EKEQDCB Name EKEQFCBA Phase 1~ Frequency Hz 50 Voltage V 230 Min. % -10 Max. % 10 Voltage range EKEQMCBA V3 • Ventilation • EKEQ 3 • Accessory • EKEQ 2 Specifications 2-2 Electrical Specifications Wiring connections EKEQDCB For power supply For connection with indoor For remote control 2 3 Remark Earth wire included Quantity 2 Remark F1,F2 Quantity Remark P1,P2 (for service) Y1~Y6 Thermistors liquid pipe Quantity 2 Remark R1,R2 Thermistors gas pipe Quantity 2 Remark R3,R4 ON/OFF Error signal Operation signal Capacity steps Fan on/off Defrost signal EKEQMCBA 2 P1,P2 For expansion valve Quantity kit Remark Thermistor air P1,P2 6 Quantity 2 - 2 Remark R5,R6 - R5,R6 Quantity 2 Remark T1,T2 Quantity - 2 - Remark - C1,C2 - Quantity - 2 - Remark - C3,C4 - Quantity - 2 - Remark - C5,C6 - Remark C1,C2 C7,C8 Quantity - 2 - Remark - C9,C10 - Quantity Power supply intake 4 EKEQFCBA Quantity 2 Bottom • Ventilation • EKEQ C1,C2 • Accessory • EKEQ 3 Options 3-1 Options 3 EKEQ Nr. Item 1 Remote control / Wired type 2 3 Wiring adapter for electrical appendices Remote sensor 4 Valve kit EKEQFCBA BRC1D528 (*) BRC1E52A(*) BRC1E52B(*) BRC2E52C(*) BRC3E52C(*) / / EKEXV50 EKEXV63 EKEXV80 EKEXV100 EKEXV125 EKEXV140 EKEXV200 EKEXV250 EKEXV400 EKEXV500 EKEQDCB EKEQMCBA BRC1D528 BRC1E52A BRC1E52B BRC2E52C BRC3E52C KRP4A516 KRCS01-1 EKEXV63 EKEXV80 EKEXV100 EKEXV125 EKEXV140 EKEXV200 EKEXV250 3 EKEXV50 EKEXV63 EKEXV80 EKEXV100 EKEXV125 EKEXV140 EKEXV200 EKEXV250 EKEXV400 EKEXV500 (*) Useful accessory tool for service and installation, but not required for operation CAUTION 1. The control boxes can be connected to the following DIII-NET devices: iTouch Manager II and Modbus Interface DIII. 2. 2QO\XVHWKLVV\VWHPLQFRPELQDWLRQZLWKD¿HOGVXSSOLHGDLUKDQGOLQJXQLW Do not connect this system to other indoor units. 3. Refer to the combination table for the application of the valve kits. 4D090226 • Ventilation • EKEQ 5 • Accessory • EKEQ 4 Control systems 4-1 Control Systems In order to maximize installation flexibility, 4 types of control systems are offered 4 Control w: Off the shelf control of air temperature (discharge temperature, suction temperature, room temperature) via any DDC controller Control x: Precize control of air temperature (discharge temperature, suction temperature, room temperature) requiring a preprogrammed DDC controller (for special applications) Control y: Control of refrigerant (Te/Tc) temperature via Daikin control (no DDC controller needed) Control z: Control of air temperature (suction temperature, room temperature) via Daikin control (no DDC controller needed) Possibility W (Td/Tr control): Possibility X (Td/Tr control): Air temperature control via DDC controller Room temperature is controlled as a function of the air handling unit suction or discharge air (customer selection). The DDC controller is translating the temperature difference between set point and air suction temperature (or air discharge temperature or room temperature) into a proportional 0-10V signal which is transferred to the Daikin control box (EKEQFCBA). Precise air temperature control via DDC controller Room temperature is controlled as a function of the air handling unit suction or discharge air (customer selection). The DDC controller is translating the temperature difference between set point and air suction temperature (or air discharge temperature or room temperature) into a reference voltage (0-10V) which is transferred to the Daikin control box (EKEQFCBA). This reference voltage will be used as the main input value for the compressor This voltage controls the compressor frequency. frequency control. Ts DDC Ts Td Te AHU Daikin control box: EKEQFCBA Tr DDC Room Te Td AHU Daikin control box: EKEQFCBA Tr Room Possibility Y (Te/Tc control): Possibility Z (Ts/Tr control): By fixed evaporating /condensing temperature A fixed target evaporating temperature of between 3°C and 8°C can be set by the customer. In this case, room temperature is only indirectly controlled. The cooling load is determined from the actual evaporating temperature (i.e. load to the heat Control your AHU just like a VRV indoor unit with 100% fresh air (BRC1D52 or BRC1E52A/B - optional) Set point can be fixed via standard Daikin infrared remote control. Remote ON/OFF can be achieved by an optional adapter KRP4A51. No external DDC controller should be connected. The cooling load is exchanger). A Daikin infrared remote control (BRC1D52 or BRC1E52A/B - optional) can be connected for error indication. determined from the air suction temperature and set point on the Daikin controller. ON / OFF KRP4A51 Daikin control box: EKEQFCBA AHU Te Ts Tr Ts Td Daikin control box: EKEQDCB EKEQMCB Room BRC1D52 BRC1E52A/B Room BRC1D52 BRC1E52A/B Tr = Room temperature AHU = Air Handling Unit Te = Evaporating temperature DDC = Digital Display Controller EKEQFCBA Possibility y EKEQDCB EKFQMCBA* * EKEQMCB (for ’multi’ application) 6 Tr Td = Air discharge temperature Possibility w Possibility z Td Ts = Air suction temperature Option kit Possibility x Te AHU • Ventilation • EKEQ Features DDC controller is required temperature control using air suction or air discharge temperature DDC and Microtech controller is required Precise Temperature control using air suction or air discharge temperature Using fixed evaporating temperature, no set point can be set using remote control Using Daikin infrared remote control BRCD or BRCEA/B Temperature control using air suction temperature • Accessory • EKEQ 5 Combination table 5-1 Combination Table 3 EKEQ Outdoor unit System A System B System B ERQ100 1 ERQ125 -phase ERQ140 ERQ125 3 ERQ200 -phase ERQ250 VRV III VRV IV Control box Expansion valve kit Options EKEQDCBV3 EKEQFCBAV3 EKEQMCBAV3 EKEXV50 EKEXV63 EKEXV80 EKEXV100 EKEXV125 EKEXV140 EKEXV200 EKEXV250 EKEXV400 EKEXV500 EKDK04 KWC26B160 KWC26B280 KRC19-26A6 P P P P P P 0 0 P P P P P P P 0 0 P P P P P P 0 0 P P P P P P P 0 0 P P P P P P P 0 0 P P P P P P 0 0 n1 n1 n1 n1 n1 n1 n1 n1 n1 n1 n1 See note 1 1 -> 3 n2 n2 n2 n2 n2 n2 n2 n2 n2 n2 n2 See note 1 5 P (pair application): combination depends on the capacity of the air handling unit n1 (multi application: combination of air handling units and VRV DX indoor units): to determine the quantity, refer to 3D090229. n2 (multi application: multiple air handling units, or the combination of air handling units and VRV DX indoor units): to determine the quantity, refer to 3D090229. NOTES 1. See outdoor unit. The system can only be connected to the following DIII-NET devices: iTouch Manager II and Modbus Interface DIII. 2. Control box EKEQD can only be connected to an ERQ outdoor unit (pair application). 3. Control box EKEQFA can be connected to an ERQ outdoor unit in pair application. Control box EKEQFA can be connected to some types of VRV IV outdoor unit (with a maximum of 3 boxes per outdoor unit). Do not combine EKEQFA control boxes with VRV DX indoor units, RA indoor units, or Hydroboxes. For details, refer to the combination table drawing of the outdoor unit. 4. The control box EKEQMA can only be connected to a VRV outdoor unit in multi application. 5. Depending on the type of air handling unit, an appropriate expansion valve kit EKEXV must be selected using following limitations: SH (superheat) = 5K and SC (subcool) = 3K Cooling Heating Allowed heat exchanger capacity [kW] minimum maximum 50 5.0 6.2 63 6.3 7.8 80 7.9 9.9 100 10.0 12.3 125 12.4 15.4 140 15.5 17.6 200 17.7 24.6 250 24.7 30.8 400 35.4 49.5 500 49.6 61.6 Saturated evaporating temperature: 6°C Air temperature: 27°C DB / 19°C WB Allowed heat exchanger capacity [kW] minimum maximum 50 5.6 7.0 63 7.1 8.8 80 8.9 11.1 100 11.2 13.8 125 13.9 17.3 140 17.4 19.8 200 19.9 27.7 250 27.8 34.7 400 39.8 55.0 500 55.1 69.3 Saturated evaporating temperature: 46°C Air temperature: 20°C DB EKEXV class EKEXV class 3D090631 • Ventilation • EKEQ 7 • Accessory • EKEQ 6 Dimensional drawings 6-1 Dimensional Drawings EKEQDCB 600 or more j 1 4 holes to fix control box j 2 Control box lid j 3 Screw nut for power supply cable j 4 Screw nut for expansion valve cable j 5 Screw nut for thermistor cable (liquid) R2T + (Air) R1T j 6 Screw nut for thermistor cable (gas) R3T j 7 Screw nut for communication cable to outdoor unit j 8 Screw nut for fan cable j 9 Screw nut for remote controller j 10 Screw nut for connection cable to controller 6 Service space (Note 2) 200 or more Service space (Note 2) Notes: 1 2 Installation: Make sure that the control box is installed horizontal, screw nuts position downwards. The option boxes (expansion valve and electrical control box) can be installed inside and outside. Do not install the option boxes in or on the outdoor unit. Do not put the option boxes in direct sunlight. Direct sunlight will increase the temperature inside the option boxes and may reduce its lifetime and influence its operation. Choose a flat and strong mounting surface. Operation temperature of the control box is between -10°C And 40°C Service space: Keep the space in front of the boxes free for future maintenance. 3TW32144-1 EKEQFCB j 1 4 holes to fix control box j 2 Control box lid j 3 Screw nut for power supply cable j 4 Screw nut for expansion valve cable j 5 Screw nut for thermistor cable (liquid) R2T + (gas) R3T j 6 Screw nut for fan j 7 Screw nut for connection cable to controller j 8 Stopper (closing cup) j 9 Screw nut for communication cable to outdoor unit j 10 Screw nut for connection cable to controller 600 or more Service space (Note 2) 200 or more Service space (Note 2) Notes: 1 2 Installation: Make sure that the control box is installed horizontal, screw nuts position downwards. The option boxes (expansion valve and electrical control box) can be installed inside and outside. Do not install the option boxes in or on the outdoor unit. Do not put the option boxes in direct sunlight. Direct sunlight will increase the temperature inside the option boxes and may reduce its lifetime and influence its operation. Choose a flat and strong mounting surface. Operation temperature of the control box is between -10°C And 40°C Service space: Keep the space in front of the boxes free for future maintenance. 3TW32134-1 8 • Ventilation • EKEQ • Accessory • EKEQ 6 Dimensional drawings 6-1 Dimensional Drawings 3 (.(40&% RUPRUH 6 VHUYLFH VSDFH QRWH RUPRUH VHUYLFH VSDFH QRWH 7:$ KROHVWR¿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ÀXHQFHLWVRSHUDWLRQ &KRRVHDÀDWDQGVWURQJPRXQWLQJVXUIDFH 2SHUDWLRQWHPSHUDWXUHRIWKHFRQWUROER[LVEHWZHHQ&DQG& 6HUYLFHVSDFH .HHSWKHVSDFHLQIURQWRIWKHER[HVIUHHIRUIXWXUHPDLQWHQDQFH • Ventilation • EKEQ 9 • Accessory • EKEQ 7 Wiring diagrams 7-1 Wiring Diagrams - Single Phase EKEQDCB 7 A1P A2P F1U F3U HAP K1R K4R Q1DI R7 R1T R2T R3T T1R X1M X3M X1M-R1/R2 X1M-R3/R4 X1M-R5/R6 X1M-Y1∼6 X1M-C1/C2 X1M-P1/P2 X1M-F1/F2 X1M-T1/T2 Y1E : Printed circuit board : Printed circuit board (Option KRP4) : Fuse (250V, F5A) (A1P) : Field fuse : Light emitting diode (service monitor green) : Magnetic relay : Magnetic relay (Fan) AC : Earth leakage breaker : Capacity adaptor : Thermistor (Air) : Thermistor (Liquid) : Thermistor (Gas) : Transformer (220V/21.8V) : Terminal block : Terminal block : Thermistor Liquid : Thermistor Gas : Thermistor Air : Expansion valve : Output: Fan ON/OFF : Communication remote controller : Communication outdoor : Input: ON/OFF : Electronic expansion valve 1 Use copper conductors only. 2 BLK: Black / WHT: White / RED: Red / BLU: Blue / BRN: Brown / GRY: Grey / GRN: Green / ORG: Orange / PINK: Pink / YLW: Yellow : Live : Neutral : Connector : Wire clamp : Protective earth (Screw) Outdoor : Seperate component : Optional accessory : Field wiring Wired remote control Position in switch box 2TW32146-1 EKEQFCB A1P A2P A3P F1U F2U F3U HAP K2R K3R K4R K5R K1R, KAR, KPR Q1DI R5 R6 R2T R3T T1R X1M X2M X3M Y1E X1M-R1/R2 X1M-R3/R4 X1M-Y1∼6 X2M-P1/P2 X2M-C1/C2 X2M-C3/C4 X2M-C5/C6 X1M-C7/C8 X1M-C9/C10 X2M-F1/F2 X2M-T1/T2 Only for 0-10V input : Printed circuit board : Printed circuit board (for voltage conversion) : Printed circuit board (Power supply) : Fuse (250V, F5A) (A1P) : Fuse (250V, T1A) (A3P) : Field fuse : Light emitting diode (service monitor green) : Magnetic relay (error status) AC : Magnetic relay (Operation / Compressor ON/OFF) AC : Magnetic relay (Fan) AC : Magnetic relay (Defrost signal) DC : Magnetic relay : Earth leakage breaker : Resistance (DC 120 OHM) : Capacity adaptor : Thermistor (Liquid) : Thermistor (Gas) : Transformer (220V/21.8V) : Terminal block : Terminal block : Terminal block : Electronic expansion valve : Thermistor Liquid : Thermistor Gas : Expansion valve : Communication remote controller : Output: error status : Output: Operation / Compressor ON/OFF : Input: 0-10V DC capacity control : Output: Fan ON/OFF : Output: Defrost signal : Communication outdoor : Input: ON/OFF 1 Use copper conductors only. 2 BLK: Black / WHT: White / RED: Red / BLU: Blue / BRN: Brown / GRY: Grey / GRN: Green / ORG: Orange / PINK: Pink / YLW: Yellow : Live : Neutral : Connector : Wire clamp : Protective earth (Screw) Outdoor : Seperate component : Optional accessory : Field wiring Wired remote control Position in switch box 2TW32136-1 10 • Ventilation • EKEQ • Accessory • EKEQ 7 Wiring diagrams 7-1 Wiring Diagrams - Single Phase 3 EKEQMCB A1P A2P F1U F3U HAP K1R K4R Q1DI R7 R1T R2T R3T T1R X1M X3M X1M-R1/R2 X1M-R3/R4 X1M-R5/R6 X1M-Y1∼6 X1M-C1/C2 X1M-P1/P2 X1M-F1/F2 X1M-T1/T2 Y1E : Printed circuit board : Printed circuit board (Option KRP4) : Fuse (250V, F5A) (A1P) : Field fuse : Light emitting diode (service monitor green) : Magnetic relay : Magnetic relay (Fan) AC : Earth leakage breaker : Capacity adaptor : Thermistor (Air) : Thermistor (Liquid) : Thermistor (Gas) : Transformer (220V/21.8V) : Terminal block : Terminal block : Thermistor Liquid : Thermistor Gas : Thermistor Air : Expansion valve : Output: Fan ON/OFF : Communication remote controller : Communication outdoor : Input: ON/OFF : Electronic expansion valve 7 1 Use copper conductors only. 2 BLK: Black / WHT: White / RED: Red / BLU: Blue / BRN: Brown / GRY: Grey / GRN: Green / ORG: Orange / PINK: Pink / YLW: Yellow : Live : Neutral : Connector : Wire clamp : Protective earth (Screw) Outdoor : Seperate component : Optional accessory : Field wiring Wired remote control Position in switch box 2TW32156-1 • Ventilation • EKEQ 11 • Accessory • EKEQ 8 External connection diagrams 8-1 External Connection Diagrams EKEQDCB Valve kit Air handling unit Power supply Outdoor unit Main switch Field supplied air handling unit Electronic expansion valve 8 Filter Filter Switch Max. Fuse L1 (Min. 5m) (Max. 50m) Max. Expansion valve connector L (Max. 20m) Transmission line L (Max. 100m) Switch Fuse Air handling unit controller L2 (Max. 5m) 1 2 3 4 5 Thermistor lines (3x) Power line L (Standard 2.5m) (Max. 20m) 6 7 Fan switch Digital output Control box 8 9 10 11 All wiring, components and materials to be produced on the site must comply with the applicable local and national codes. Use copper conductors only. For more details, see wiring diagram. Install a circuit breaker for safety. All field wiring and components must be provided by a licensed electrician. Unit shall be grounded in compliance with the applicable local and national codes Wiring shown are general points-of-connection guides only and are not intended for or to include all details for a specific installation. Be sure to install the switch and the fuse to the power line of each equipment. Install the main switch that can interrupt all power sources in an integrated manner because this system consists of the equipment utilizing the multiple power sources. For detailed control box side connection, see control box manual and wiring diagram. For detailed pipe connections and limitations, see manuals. Remote controller Wiring Refrigerant piping 3TW32149-1 EKEQFCB Outdoor unit Main switch Air handling unit Valve kit Power supply Electronic expansion valve Filter Field supplied air handling unit Filter Max. Switch L2 (Max. 5m) Fuse Max. L1 (Min. 5m) (Max. 50m) Transmission line L (Max. 100m) Switch Fuse Expansion valve connector L (Max. 20m) Power line 1 2 3 4 5 Fan switch Digital output 6 Control box Thermistor lines 7 L (Standard 2.5m) (Max. 20m) 8 9 L (Depend on digital controller) 10 11 Field supplied digital controller All wiring, components and materials to be produced on the site must comply with the applicable local and national codes. Use copper conductors only. For more details, see wiring diagram. Install a circuit breaker for safety. All field wiring and components must be provided by a licensed electrician. The unit shall be grounded in compliance with the applicable local and national codes. Wiring shown are general points-of-connection guides only and are not intended for or to include all details for a specific installation. Be sure to install the switch and the fuse to the power line of each equipment. Install the main switch that can interrupt all power sources in an integrated manner because this system consists of the equipment utilizing the multiple power sources. For detailed control box side connection, see control box manual and wiring diagram. For detailed pipe connections and limitations, see manuals. Wiring Refrigerant piping Digital controller 12 • Ventilation • EKEQ 3TW32139-1 • Accessory • EKEQ 8 External connection diagrams 8-1 External Connection Diagrams 3 EKEQMCB Valve kit Air handling unit Power supply Electronic expansion valve Field supplied air handling unit Main switch Filter 8 Filter Max. (Max. 5m) Switch Fuse Air handling unit controller Liquid pipe Gas pipe Expansion valve Connector L (Max. 20m) Switch Transmission Fuse Thermistor lines (3x) L (Standard 2.5m) (Max. 20m) Fan switch Digital output Power supply Control box Remote controller Notes: 1 2 3 4 5 6 7 8 9 Indoor unit 10 Remote controller 11 12 Indoor unit All wiring, components and materials to be produced on the site must comply with the applicable local and national codes. Use copper conductors only. For more details, see wiring diagram. Install a circuit breaker for safety. All field wiring and components must be provided by a licensed electrician. The unit shall be grounded in compliance with the applicable local and national codes. Wiring shown are general points-of-connection guides only and are not intended for or to include all details for a specific installation. Be sure to install the switch and the fuse to the power line of each equipment. Install the main switch that can interrupt all power sources in an integrated manner because this system consists of the equipment utilizing the multiple power sources. For detailed control box side connection, see control box manual and wiring diagram. For detailed pipe connections and limitations, see manuals. Connection appliance can be standard indoor unit or free choice of air handling unit. Remote controller Wiring Refrigerant piping 3TW32159-1 • Ventilation • EKEQ 13 The present leaflet is drawn up by way of information only and does not constitute an offer binding upon Daikin Europe N.V.. Daikin Europe N.V. has compiled the content of this leaflet to the best of its knowledge. No express or implied warranty is given for the completeness, accuracy, reliability or fitness for particular purpose of its content and the products and services presented therein. Specifications are subject to change without prior notice. Daikin Europe N.V. explicitly rejects any liability for any direct or indirect damage, in the broadest sense, arising from or related to the use and/or interpretation of this leaflet. All content is copyrighted by Daikin Europe N.V. BARCODE Daikin products are distributed by: Naamloze Vennootschap - Zandvoordestraat 300, B-8400 Oostende - Belgium - www.daikin.eu - BE 0412 120 336 - RPR Oostende EEDEN15-205 • 11/14 • Copyright Daikin The present publication supersedes EEDEN14-205 These products are not within the scope of the Eurovent certification program
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project