PowerLite Pro G5550

IP Link® Device Interface
Communication Sheet
epsn_1_4762_2.pke
Revision: 8/4/2011
This document provides additional assistance with wiring your Extron IP Link enabled product to your device.
Different components may require a different wiring scheme than those listed below.
For complete operating instructions, refer to the user's manual for the specific Extron IP Link enabled product or
the controlled device manufacturer supplied documentation.
Device Specifications:
Device Type:
Manufacturer:
Firmware Version:
Model(s):
Video Projector
Epson
N/A
EB-G5950NL, Powerlite Pro G5950NL, EB-C520XH, PowerLite Pro G5550
Version History:
Driver
Version
Date
IP Link
Compiler
GC
Version
Notes
2
8/1/2011
1.4.0
3.2.0
Extron Certified. Added models EB-C520XH, PowerLite Pro
G5550.
1
12/14/2010
1.4.0
3.0.4
Initial version.
Driver Notes:
Page 1 of 5
IP Link® Device Interface
Communication Sheet
epsn_1_4762_2.pke
Revision: 8/4/2011
Control Commands & States:
Aspect Ratio
16:9
Auto
Normal
4:3
Native
Auto Image
Execute
AV Mute
On
Off
Closed Caption
CC1-CC4
TEXT1-TEXT2
Freeze
On
Off
Input
Computer1 RGB
Computer1 (YPbPr)
Computer2 RGB
Computer2 (YPbPr)
HDMI
Video 1
Video 2
S-Video
BNC (RGB)
BNC (Component)
USB
LAN
Lamp Mode
Normal Mode
Eco Mode
Power Control
On
Off
Volume (Discrete)
0 to 20 in steps of 1
Volume (Step)
Up
Down
Page 2 of 5
Off
IP Link® Device Interface
Communication Sheet
epsn_1_4762_2.pke
Revision: 8/4/2011
Status Available:
16:9
Auto
Normal
4:3
AV Mute
On
Off
Closed Caption
CC1-CC4
TEXT1-TEXT2
Connection Status
Connected
Disconnected
Device Status
Normal
Status Unavailable
Fan Error
Internal temperature is
abnormally high
Lamp Burnt-out
Lamp Cover Error
Lamp Error
Filter Error
EDL Capacitor
Disconnected
Auto Iris Error
Subsystem Error
Low Air Flow Error
Air Flow Error
Power Supply Error
Shutter Error
Cooling System Error
Pump Error
Freeze
On
Off
Input
Computer1 RGB
Computer1 (YPbPr)
Computer2 RGB
Computer2 (YPbPr)
HDMI
Video 1
Video 2
S-Video
BNC (RGB)
BNC (Component)
USB
LAN
Lamp Mode
Normal Mode
Eco Mode
Lamp Usage
Hours
Power Status
On
Off
Cooling Down
Status Unavailable
Aspect Ratio
Volume (Discrete)
0 to 20 in steps of 1
Page 3 of 5
Native
Off
Warming Up
IP Link® Device Interface
Communication Sheet
epsn_1_4762_2.pke
Revision: 8/4/2011
MLC62 Supported Commands:
Aspect Ratio
16:9
Auto
Normal
4:3
Native
Auto Image
Execute
AV Mute
On
Off
Closed Caption
CC1-CC4
TEXT1-TEXT2
Freeze
On
Off
Input
Computer1 RGB
Computer1 (YPbPr)
Computer2 RGB
Computer2 (YPbPr)
HDMI
Video 1
Video 2
S-Video
BNC (RGB)
BNC (Component)
USB
LAN
Lamp Mode
Normal Mode
Eco Mode
Power Control
On
Off
Volume (Discrete)
0 to 20 in steps of 1
Volume (Step)
Up
Down
Page 4 of 5
Off
epsn_1_4762_2.pke
IP Link® Device Interface
Communication Sheet
Cable and Adapter Requirements:
F/F RS-232 Null Modem Serial Cable
Notes for the Device:
Serial communication:
Port Type: RS-232
Baud Rate: 9600
Data Bits: 8
Parity: None
Stop Bits: 1
Flow Control: None
Pin Assignments Diagram:
Note: Captive screw connector may also be used as a serial connection.
General Notes:
Page 5 of 5
Revision: 8/4/2011