The Theater at Colorado Heights
Theater Manager - Dennis Leach
O: 303-937-4009
C: 720-985-4886
DLeach@CHU.edu
Technical Coordinator – Cullen Munch
O: 303-937-4012
C: 303-570-6241
CMunch@CHU.edu
Director of Sales & Events – Sara J. Sylvester
O: 303-937-4008
C: 303-378-0228
Ssylvester@CHU.edu
BASICS
Seating Capacity:
Orchestra: 633
Stage Floor:
Balcony: 288
No Rake
Total Capacity: 921
Proscenium:
43’6” x 22’0”
Stage:
35’0” Plaster Line to Back Wall
46’8” Centerline to Stage Right Wall
Oak over Concrete
Flat Black
Soft Goods:
Gold Main Curtain, Center traveling, Operated
S.R. - 2’5” From Plaster Line
[4] Legs, Black Velour, 50% Fullness.
8’0” x 25’0” - 20’0” off Center Line
41’8” Centerline to Stage Left Wall
Leg #1 - 8’5” From Plaster Line
54’0” Stage Deck to Grid
Leg #2* - 14’5” From Plaster Line
Leg #3 - 21’5” From Plaster Line
Apron:
60’0” Full Width
Leg #4 - 28’1” From Plaster Line
15’2” Front Center to Plaster Line
*(Leg #2 also a Mid-stage Traveler,
Operated S.L.)
43’7” Width of Pit Lift
11’9” Front Center to Pit Lift Line
Backstage Crossover:
Stage Right Wing:
Stage Left Wing:
Black Scrim:
47’0” X 29’0”
Cyclorama:
Back Wall - Plaster White Bounce
Fly System:
Single Purchase Counterweight Fly System
15’3” x 88’2”
35’9” X 18’0”
35’9” X 10’4”
40 Line Sets
49’6” Maximum Height
Hydraulic Pit Lift:
Contained Within Stage Apron
Maximum Load Capacity (per line set):
Adjustable: Stage Level, House Level,
Approximately 1,000 lbs.
Orchestra Pit and Basement Level
Locking Rail: Stage Left, Stage Level
Maximum Lift Capacity: 22,000 Lbs.
Dressing Rooms:
Main Dressing Room: 59 Mirror Makeup Room
Other Measurements:
Main Lobby: 78’0” x 16’0”
Private Men’s Dressing Room: Bathroom,
Loading Dock: 76’0” X 11’10”
Makeup Room & Prep Area
Bonfils Room: 25’6” x ?
Private Women’s Dressing Room: Bathroom,
Costume Shop: 61’0” X 11’6”
Makeup Room & Prep Area
Stage II: 60’0” x 48’6”
Scenic Painting Frame: 50’6” X 27’0”
Other Available Items: Marley Dance Floor
Stage II Lobby: 68’6” x 16’0”
Flags with Bases (Colorado, America, Japan)
Art Gallery: 76’6” x 23’8”
Steinway Baby Grand Piano (6’)
Dance Studio: 47’0” x 25’6”
Risers (various styles and sizes)
Main Dressing Room: 44’6” x 21’5”
Ballet Barres (various styles and sizes)
Scenic Painting Frame
LITTLE F-10 1500w Follow Spot
Bi-folds for Quick Change Rooms/Partitions
[2] Podiums
Tables & Chairs (Various styles and sizes)
Available Storage Closets
Projector and Laptop
Drafting Table, Gels, Gobos
TV/DVD Player on library cart
Additional Marley Floor Panels for Warm-Up
Areas (condition varies)
[4] Costume Racks
*Possible Rental Cost Associated With Certain Items
SOUND
Sound Control is located balcony level in Booth
Signal Send/Return:
Rapco 24 channel Snake: 2 open Return Lines
[From/To Booth] XXX 24 channel Snake: 4 open Return Lines
Composite Video Cable
Mixer:
Yamaha 2404
VGA Cable
24 channels
Additional 24 channel snake available for stage
2 Auxiliaries
Playback:
TEAC PED 500 CD Player (2 trays)
1/8th” jack for PC/MP3 player
runs
Stage Audio Feed:
Microphone in House Left Cove (Production
Feed to Dressing Room)
Microphone Stage Right Manager Desk (Call
Processing:
EQ: (3) RANE ME30 Graphic EQ
Mic to Dressing Room)
Compression: X
Delay: Time Machine RDS 1000/Yamaha
Comms/Headset:
GC2020R/RANE MPE 28 EQ
Clear Comm CS-200K Station
Comm Locations: Stage Right/Stage
Left/Sound Op/Light Op
House Speaker System:
Can provide up to (2) additional comm packs
(4) Bose 802 Speaker Cluster Centered on
Proscenium
(6) Bose 102 Delay Speakers Mounted Under
Balcony
(2) Yamaha S4115H II Stage Level (L & R)
Microphones:
SM57: 9
EV N/D 257A: 1
SM58: 1
EV N/D 408B: 1
Beta 58: 5
EV N/D 308B: 1
AT-8531: 2
Arista 10-075: 1
*Shure ULX SM58: 2 *Shure ULX LAV: 2
Stage Monitor System: (2-4) EV 1202
Amplifiers:
(3) QSC 1500/(1) EV 7300/(1) Yamaha
P2201/Crest
*Our Shure wireless system has 2 receivers, therefore is capable of 2
mics maximum
LIGHTING
Lighting control is located balcony level
in Booth
Control Board:
ETC Element
Dimmer Rack:
Strand CD-80
INSTRUMENT
SCHEDULE & REP
GROUND PLAN
Channel
Dimmer
Unit Type
Position
Purpose
Channel
Dimmer
Unit Type
Position
Purpose
1
1 Leko
FOH2
Pit Wash
30
44, 49 Leko
SL Side Bar
Wing 3 SL
2
2 Leko
FOH2
Pit Wash
31
46, 48 Leko
SL Side Bar
Wing 4 SL
3
3 Leko
FOH2
Pit Wash
32
69 PAR
3rd Elec.
4
4 Leko
FOH2
Mid Wash
33
72 PAR
3rd Elec.
5
5 Leko
FOH2
Mid Wash
34
Leko
SR Cove
6
6 Leko
FOH2
Mid Wash
35
54 Leko
SR Cove
7
24 Fresnel
1st Elec.
DS Wash
36
Leko
SL Cove
8
23 Fresnel
1st Elec.
DS Wash
37
55 Leko
SL Cove
9
22 Fresnel
1st Elec.
DS Wash
40
42 Leko
FOH2
SR
10
21 Fresnel
1st Elec.
DS Wash
41
8 Leko
FOH2
C
11
95, 90 Fresnel
2nd Elec.
Mid Wash
42
7 Leko
FOH2
SL
12
89, 92 Fresnel
2nd Elec.
Mid Wash
43
20 Leko
1st Elec.
13
94, 93 Fresnel
2nd Elec.
Mid Wash
44
13 Leko
1st Elec.
14
19, 17 Fresnel
3rd Elec.
Mid Wash
45
29 Leko
1st Elec.
15
16, 18 Fresnel
3rd Elec.
Mid Wash
46
91 Leko
2nd Elec.
16
96, 70 Fresnel
3rd Elec.
Mid Wash
47
71 Leko
3rd Elec.
17
14, 87 Fresnel
4th Elec.
US Wash
48
47 Leko
4th Elec.
18
86, 85 Fresnel
4th Elec.
US Wash
50
30, 31 Strip
1st Strip
19
15, 12 Fresnel
4th Elec.
US Wash
51
32, 33 Strip
1st Strip
20
28 PAR
1st Elec.
52
34, 35 Strip
1st Strip
21
27 PAR
1st Elec.
53
36, 37 Strip
2nd Strip
22
26 PAR
1st Elec.
54
38, 39 Strip
2nd Strip
23
25 PAR
1st Elec.
55
40, 41 Strip
2nd Strip
24
73, 74 Leko
SR Side Bar
Wing 1 SR
56
Strip
3rd Strip
25
52, 77 Leko
SR Side Bar
Wing 2 SR
57
Strip
3rd Strip
26
53, 75 Leko
SR Side Bar
Wing 3 SR
58
Strip
3rd Strip
27
51, 76 Leko
SR Side Bar
Wing 4 SR
59
57, 58 CYC Strip
4th Strip
blue
28
45, 50 Leko
SL Side Bar
Wing 1 SL
60
59 CYC Strip
4th Strip
red
29
43, 56 Leko
SL Side Bar
Wing 2 SL
61
60 CYC Strip
4th Strip
green
FLY LINE ASSIGNMENTS
1: Projection Screen
21: OPEN
2: House Border
22: OPEN
3: House Main Drape
23: Strip Lights #3
4: 1st Electric
24: OPEN
5: Strip Lights #1
25: Black Border #3
6: CYSO Work Lights
26: Legs #3
7: OPEN
27: OPEN
8: OPEN
28: OPEN
9: Black Border #1
29: OPEN
10: Legs #1
30: OPEN
11: 2nd Electric
31: 4th Electric
12: OPEN
32: Legs #4
13: OPEN
33: OPEN
14: Strip Lights #2
34: OPEN
15: Black Border #2
35: CYC StripLights
16: Legs #2 (Mid-stage Traveler )
36: SR Side Lights
17: OPEN
37: SL Side Lights
18: 3rd Electric
38: OPEN
19: CYSO Work Lights
39: OPEN
20: OPEN
40: Black Scrim
GENERAL INFORMATION
- Please find a CHU staff member if there is any problem or issue. We are
here to help and take pride in keeping our theater clean, safe and comfortable.
(Bathrooms/Trash/Temperature ect.)
- CHU boasts one of the largest theaters in Colorado. With plenty of space
and ancillary rooms, it can be easy to forget everything included in your rental.
Any of these spaces can be tailored to fit a productions unique demands, you
need only ask.
- There is no food or drink allowed in the auditorium (bottled water OK)
- Parking for your event will be in Lot H. Capacity is 286 vehicles. Handicap
patrons are allowed to park in Lot A for easier lobby access. Any other
parking arrangements need to be cleared with CHU before the event. (please
reference the map provided in this packet)
- Load ins and Load outs must be coordinated with CHU. Please advance load
in & load out times with any companies/vendors/drivers involved in your
production.
- Our loading dock is basement level and we use our orchestra pit as a freight
elevator. Once anything is set up on the apron of the stage(Judges Tables, Set
Pieces, Orchestra) the lift cannot move down again.
- There is no standing room in the auditorium
- There is no smoking within 20 feet of the building. Please ask a CHU staff
member for the nearest designated smoking area
- Wireless internet is available in both the lobby and the auditorium. However,
its signal strength varies. Please let us know in advance if your production
requires constant and consistent internet access.
- You are responsible for your equipment, props, sets and staff.
- There is no running in the theater
- DO NOT tape anything to any wall or surface without first receiving
permission
- DO NOT tamper with air units, doors, light fixtures or posted signs
- There are several areas in the theater that are closed to clients and the public.
These areas are clearly marked with “No Access Permitted” signs.
- Handicap accessible bathrooms are located in the main lobby (Women) and
in the library adjacent to the lobby(Men)
- If you plan to use any of our staff for running crew or stage management,
please let us know in advance so we can properly assign tasks and prepare.
- Only CHU staff is allowed to operate the pit lift, scissor lift, fly system and
elevator unless previously cleared with the Technical Coordinator or Theater
Manager.
THEATER CATWALK
THEATER LAYOUT
CAMPUS MAP