PHW Hoods
Revised
02/26/08
10 3/4” (27.3 cm)
30”, 36” Wide
Preference™ Hoods
1/2
PLANNING
GUIDE
All tolerances: +1/16”, -0, (+1.6mm, -0)
unless otherwise stated
11 7/8” (30.2 cm)
8” (203mm)
8” Dia.
203.2 cm)
Chimney Mounting Bracket
26 1/8” (66.4 cm)
Min.*
44” (111.8 cm)
Max.*
25 3/8” * 19 3/4” *
(64.5 cm) (50.2 cm)
REAR OF BLOWER UNIT
5/16”
(0.3 cm)
GLASS
5 3/4”
(14.6 cm)
19 3/4”
(50.2 cm)
30” (76.2 cm) or
36” (91.4 cm)
30”
(76.2 cm)
COOKTOP SURFACE
phw overall dimensions
Side View
General Specifications
ALL MODELS
Blower
600 CFM with electronic speed control
Blower
Speeds
4
Lights
120 Vac, 50 W halogen (1)
Filters
Mesh type, dishwasher safe (2)
Exhaust
Finish
8-inch
WARNING
The minimum installed distance from the rear of blower unit
base to the cooktop surface must be no less than
30” inches (76.2 cm), 26 inches (66.0 cm) for an electric
cooktop. The minimum specified distance may be higher for the
particular range or cooktop in use. Check the manufacturers
specifications for the cooktop or range.
430 stainless steel with tempered
glass hood
Power
Required
120 Vac, 60 Hz, 3.5 Amp
Circuit
Required
120 Vac, 60 Hz, 15 Amp
Web: http://www.Dacor.com
Corporate Phone: 800-793-0093
Specifications are subject to change without notice.
See installation instructions for additional details.
7.9
PHW Hoods
Revised
02/26/08
30”, 36” Wide
Preference™ Hoods
Calculating the Maximum Duct Run Length
2/2
PLANNING
GUIDE
The hood may exhaust through the ceiling on through a rear wall.
The maximum straight duct length for the hood is 50 feet. For each
elbow and transition added to the duct work, a certain number
of feet must be subtracted from the maximum straight length to
compensate for wind resistance. To determine the length the duct
work cannot exceed, subtract all of the equivalent lengths of the
elbows and transitions listed below from 50 feet.
DUCT PIECE
SUBTRACT
90° elbow (8”)
7 feet
45° elbow (8”)
3 feet
3 1/4” x 10” to 8” round
4 feet
Wall cap with damper
30 feet
Roof cap
30 feet
Duct Work Equivalent Lengths
Web: http://www.Dacor.com
Corporate Phone: 800-793-0093
EXAMPLE OF REAR EXHAUST
Specifications are subject to change without notice.
See installation instructions for additional details.
7.10