Data Sheet
Model No.:VR152
Document Number: SDS0205
Specifications
Revision:5
Page 1 of 3
:
Model No
Battery Type
For use with
Color
Battery
Nominal Voltage
Cut Off Voltage
Nominal Capacity
Minimum Capacity
Continuous Operation Time*
Temperature Range
:
:
:
:
:
:
:
:
Casing Material
Typical Weight
Charging
:
:
:
Leakage Test
:
Safety
:
Warranty
:
:
:
VR152
Nickel Metal Hydride
Sharp View Cam VL-E78E
Black (B)
3 X NT250AFH
3.6V
3.0V
2500 mAh at 0.2C**
2350 mAh at 0.2C**
Not Applicable
Charge
: 0 ~ 45°C
Discharge : -20 ~ 50°C
Storage : -20 ~ 50°C
ABS
130g
Battery should be charged in an Original
Manufacturer charger.
First Charge Rate
: 0.1C
Subsequent Charge Rate : 0.1C ~ 1C
Leakage test starts after battery is fully discharged. Battery
shall be placed under load. The battery should be monitored
for a period up to two months but not less than ten days.
Each battery is equipped with a thermistor and thermostat
to protect battery from high temperature and/or short circuit
Each cell is also equipped with a safety vent system
in case abuses occur.
Six (6) months limited warranty from date of purchase.
'*'data valid only when the battery pack is on fully charged condition.
**" Battery pack should be firstly charged and discharged for 3 complete cycles as a warm-up. The pack
should then be charged at 0.1C and its capacity be measured by discharging at 0.2C till cut.
"Sharp" is registered trademarks of the Sharp Corporation.
Data Sheet
Document Number: SDS0205
Model No.:VR152
Revision:5
Mechanical Drawing :
Remark: Dimensions showed are for reference only. For detail, please refer to the engineering drawing.
Page 2 of 3
Data Sheet
Document Number: SDS0205
Circuit Diagram :
Model No.:VR152
Revision:5
Page 3 of 3