SGM304, SGM365, SGM466 - Appliances Connection

SGM304, SGM365, SGM466
Document # PG04-004
Revised 10/01/11 Page 1/5
30”, 36”, 46” Wide,
Classic Drop-in Gas Cooktops
PLANNING
GUIDE
warning
All tolerances ±1/16” (±1.6 mm), unless otherwise noted.
•
Observe all governing codes and ordinances during planning
and installation. Contact your local building department for
further information.
•
This appliance must be installed in accordance with the
accompanying installation instructions.
1 5/8" (4.1 cm)
bottom of base
to cooking surface
30"
(76.2 cm)
4" (10.2 cm)
chassis height
21"
(53.3 cm)
Product dimensions model sgm304
27 5/8" *
(70.2 cm)
19 1/2" *
(49.5 cm)
* including embosses/screws in side of chassis
1 5/8" (4.1 cm)
bottom of base
to cooking surface
36"
(91.4 cm)
4" (10.2 cm)
chassis height
Product dimensions model sgm365
21"
(53.3 cm)
33 1/2" *
(85.1 cm)
19 1/2" *
(49.5 cm)
4" (10.2 cm)
chassis height
* including embosses in side of chassis
46"
(116.8 cm)
1 5/8" (4.1 cm)
bottom of base
to cooking surface
44 5/8" *
(113.3 cm)
21"
(53.3 cm)
19 1/2" *
(49.5 cm)
Product dimensions model sgm466
* including embosses/screws in side of chassis
Specifications subject to change without notice.
www.dacor.com
Phone: (800) 793-0093
4.1
SGM304, SGM365, SGM466
Document # PG04-004
Revised 10/01/11 Page 2/5
30”, 36”, 46” Wide,
Classic Drop-in Gas Cooktops
Electrical Requirements
Gas Supply Requirements
WARNING
To prevent an electric shock hazard, the power supply must meet
the specifications stated below. It is the owner’s responsibility
to make sure that the electrical service meets electrical requirements and that the electrical outlet has been properly installed.
◊
◊
PLANNING
GUIDE
The cooktop is supplied with a factory installed, 40-inch, three-prong,
grounding electrical plug. It is connected to the chassis at the bottom
right rear corner (see Chassis Bottom Diagram below). It must be
connected to a dedicated, grounded three-prong electrical outlet
installed by a licensed electrician.
The electrical installation, including minimum supply wire size and
grounding, must be done in accordance with National Electric Code
ANSI/NFPA 70* and local codes and ordinances. A copy of this
standard may be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, Massachusetts 02269-9101
◊
The correct voltage, frequency and amperage must be supplied to
the electrical outlet according to the product data label located on the
bottom of the chassis. See the Gas and Electrical Requirements table
on this page for reference.
◊
Be certain to locate the electrical outlet so that the power cord may be
easily disconnected if the unit needs service.
◊
Be certain that the cooktop being installed is correct for the gas
service being provided (natural gas or LP gas). Also, if operating
the cooktop at an altitude above 4000 ft. (1219 m) make sure it is
equipped for high altitude operation.
◊
Units equipped for LP operation have “LP” in the model number listed
on the product data label. See the Chassis Bottom Diagram for label
location.
◊
Units equipped for high altitude operation have an “H” at the end of
the model number listed on the product data label.
◊
Check your local building codes for the proper method of installation.
In the absence of local codes, this appliance should be installed in
accordance with the National Fuel Gas Code ANSI Z223.1/NFPA 54.
◊
An external manual shut-off valve must be installed between the gas
inlet and the cooktop for the purpose of turning on or shutting off gas
to the appliance.
◊
The cooktop comes from the factory with a regulator in the shipping
carton. Use only the regulator provided. The regulator must be
installed in the gas line that runs from the cooktop gas inlet to the gas
shut off valve.
◊
Models SGM304 and SGM365 come with a 1/2” regulator. Model
SGM466 comes with a 3/4” regulator, approved for connection to a
1/2” house gas supply.
The cooktop gas connection is located on the bottom of the cootktop in the
back right corner as you face the front of the unit. See the Chassis Bottom
Diagram on this page.
SGM304
SGM365
SGM466
SGM304LP
SGM365LP
SGM466LP
Gas type
Natural
LPG
Manifold
pressure
4” Water column
10” Water column
Min. gas supply
pressure**
5” Water column
11” Water column
Max. gas supply
pressure
1/2 p.s.i.
1/2 p.s.i.
0.25 Amp.
(0.03 kW)
0.25 Amp.
(0.03 kW)
120 Vac,
60 Hz, 15 Amp.
120 Vac,
60 Hz, 15 Amp.
Front of unit
Product data label
Gas inlet Electric cord
Chassis Bottom Diagram
Total connected load
Circuit requirement
Gas and Electrical Requirements*
* The electrical and gas data on this page is for reference only. If the
above data does not agree with the product data label, use the data on the
product data label.
** The gas supply pressure for testing the regulator setting shall be at least
1 inch water column (249 Pa) above the specified manifold pressure.
Specifications subject to change without notice.
www.dacor.com
Phone: (800) 793-0093
4.2
SGM304, SGM365, SGM466
Document # PG04-004
Revised 10/01/11 Page 3/5
30”, 36”, 46” Wide,
Classic Drop-in Gas Cooktops
Cabinet and Countertop Layout
◊
WARNING
•
To reduce the risk of personal injury caused by reaching over
a hot appliance, avoid locating cabinet storage space directly
above the cooktop.
•
Failure to meet or exceed the maximum and minimum
dimensions/clearances stated in these instructions may result
in a fire hazard.
•
Follow the countertop manufacturer’s instructions regarding
the minimum corner radius, use of heat reflective tape,
reinforcement of corners, etc.
◊
◊
Allow a minimum 1/4” (6 mm) clearance between the bottom of the
cooktop chassis and all combustible surfaces, including the upper
edge of a drawer installed below the cooktop.
Cabinet tolerances: +1/16” (+1.6 mm), -0,
unless otherwise stated
Under Cabinet Clearances
(B) Minimum*
SGM304
29” (73.7 cm)
SGM365
35 1/4” (89.5 cm)
SGM466
46” (116.8 cm)
* To allow clearance for hold down brackets
The gas supply piping, gas shut-off valve and the electrical outlet
must be located so they do not interfere with the cooktop when it is
installed. If installing another appliance in the cabinet below, allow for
the routing of gas and electrical service behind it.
The installation must allow for the following:
18" min.1, 3
(45.7 cm)
See cutout
dimensions
A
13" max.3
(33.0 cm)
2
30" min.1,
(76.2 cm)
Model
◊
Combustible overhead
cabinets
Combustible
surface to rear
1/4” (6 mm)
min. clearance
to combustible
surfaces
B
Carefully check the location where the cooktop will be installed. For
best performance, the cooktop should be placed away from drafts that
may be caused by doors, windows and heating and air conditioning
outlets.
This appliance is to be used in conjunction with a suitable vent hood
or approved Dacor raised vent system.
PLANNING
GUIDE
◊
Access to the gas shut-off valve and regulator when the unit is
installed.
◊
Access to the electrical outlet when the cooktop is in place. The 40”
(101.6 cm) power cord must be able to reach the electrical outlet
◊
Access to the underside of the cooktop for service and inspection
purposes
◊
Clearance inside the cabinet to allow for proper hold down bracket
installation.
To allow access to the utilities and cooktop bottom, a fixed shelf should
not be installed below the cooktop. See the following pages for countertop
cutout dimensions.
1 7/8" min.
(4.8 cm)
Raised Vent Compatibility
If installing the cooktop with a raised vent, install only the approved Dacor
model numbers specified below:
7 1/2” (19.1 cm) min. to
combustible side wall,
above counter both sides
1
Measured from cooking surface (top of cooktop grate).
2
If installing with an overhead vent hood, also check hood
specifications for minimum required clearances.
3
Not applicable for cabinets more than a horizontal distance of 6”
(15.2 cm) from edge of cooktop. Allow 7 1/2” (19.1 cm) from edge
of cutout.
Cooktop Models
Approved Raised Vent Models
SGM304
ERV30, PRV30 or RV30
SGM365
ERV36, PRV36 or RV36
SGM466
PRV46 or RV46
Minimum Required Clearances Around the Cooktop
Model
(A) Minimum
(A) Recommended
SGM304
30” (76.2 cm)
36” (91.4 cm)
SGM365
36” (91.4 cm)
42” (106.7 cm)
SGM466
48” (121.9 cm)
54” (137.2 cm)
Specifications subject to change without notice.
www.dacor.com
Phone: (800) 793-0093
4.3
SGM304, SGM365, SGM466
Document # PG04-004
Revised 10/01/11 Page 4/5
30”, 36”, 46” Wide,
Classic Drop-in Gas Cooktops
Cutout Dimensions
PLANNING
GUIDE
Cutout tolerances +1/16” (+1.6 mm), -0, unless otherwise noted
IMPORTANT: Be careful to use the correct cutout diagram (on page 5/5) to determine the countertop dimensions for the installation type. Carefully double
check all dimensions against the table below and the correct diagram before cutting the countertop.
Countertop Dimensions
Cutout
Diagram
(C) Min.
(D)
(E)
(F)
(G)
(H)
SGM304
without raised vent
Figure 1
(Square)
2 7/8”
(7.3 cm)
19 3/4”
(50.2 cm)
27 3/4”
(68.6 cm)
NA
NA
NA
SGM304
with ERV30 or PRV30
Figure 1
(Square)
3/8”
(1.0 cm)
22 1/2” *
(57.2 cm)
27 3/4”
(68.6 cm)
NA
NA
NA
SGM304
with RV30
Figure 1
(Square)
5/8”
(1.6 cm)
22 1/4” *
(56.5 cm)
27 3/4”
(68.6 cm)
NA
NA
NA
SGM365
without raised vent
Figure 1
(Square)
2 7/8”
(7.3 cm)
19 3/4”
(50.2 cm)
33 5/8”
(85.4 cm)
NA
NA
NA
SGM365
with ERV36 or PRV36
Figure 1
(Square)
3/8”
(1.0 cm)
22 1/2” *
(57.2 cm)
33 5/8”
(85.4 cm)
NA
NA
NA
SGM365
with RV36
Figure 1
(Square)
5/8”
(1.6 cm)
22 1/4” *
(56.5 cm)
33 5/8”
(85.4 cm)
NA
NA
NA
SGM466
without raised vent
Figure 1
(Square)
2 7/8”
(7.3 cm)
19 3/4”
(50.2 cm)
44 3/4”
(113.7 cm)
NA
NA
NA
SGM466
with PRV46
Figure 2
(Notched)
3/8”
(1.0 cm)
22 1/2” *
(57.2 cm)
44 3/4”
(113.7 cm)
43 1/2”
(110.5 cm)
5/8”
(1.6 cm)
2 5/8” **
(6.7 cm)
SGM466
with RV46
Figure 2
(Notched)
5/8”
(1.6 cm)
22 1/4” *
(56.5 cm)
44 3/4”
(113.7 cm)
43 1/2”
(110.5 cm)
5/8”
(1.6 cm)
2 5/8” **
(6.7 cm)
Installation Type
* Total cutout depth, accommodates both the cooktop and raised vent
** IMPORTANT: Notch depth is included in total cutout depth (D). DO NOT add notch depth to total cutout depth (D).
3/8” min. (1.0 cm)
flat countertop overhang
required behind cutout
Stiffener
5/8” min. (1.6 cm)
flat countertop overhang
required behind cutout
Countertop
SGM series cooktop
Stiffener
SGM series cooktop
Cabinet face
Cabinet face
5/8” min. (1.6 cm) space
behind raised vent
chassis to clear stiffener
3/8” min. (1.0 cm) space
behind raised vent
chassis to clear stiffener
RV series raised vent:
Check raised vent
dimensions/specifications
to determine proper fit
ERV or PRV series raised
vent: Check raised vent
dimensions/specifications
to determine proper fit
4 5/8” (11.7 cm)
9 7/8” (25.1 cm) with
CABP3 blower installed
Floor
Floor
Side View - sgm Series Cooktop with
ERV OR PRV Series Raised Vent
Specifications subject to change without notice.
Countertop
Side View - sgm Series Cooktop with
RV Series Raised Vent
www.dacor.com
Phone: (800) 793-0093
4.4
SGM304, SGM365, SGM466
Document # PG04-004
Revised 10/01/11 Page 5/5
30”, 36”, 46” Wide,
Classic Drop-in Gas Cooktops
PLANNING
GUIDE
Cutout tolerances +1/16” (+1.6
mm), -0, unless otherwise noted
Rear
wall
Vertical
combustible
surface
4 1/4" (10.8 cm) min.
from mounting surface to
combustibles below
cooktop chassis
C
E
7 1/2" (19.1 cm) min.
to combustible
side wall above
countertop
(both sides)
D
1 7/8" min.
(4.8 cm)
Figure 1 - Square Countertop Cutout Diagram
4 1/4" (10.8 cm) min. from
mounting surface to combustibles
below cooktop chassis
Rear
wall
H
Vertical
combustible
surface
F
G
C
H
E
7 1/2" (19.1 cm) min.
to combustible
side wall above
countertop
(both sides)
D
1 7/8" min.
(4.8 cm)
Figure 2 - Notched Countertop Cutout Diagram
Specifications subject to change without notice.
www.dacor.com
Phone: (800) 793-0093
4.5