Downdraft Vent
E36DD75ESS
36" DOWNDRAFT VENT
FEATURES
Nominal Width
Installation Type
Controls
Air Discharge
Air Delivery (CFM)
Intake Area
Blower Type (Remote)*
Fan Speeds
Dishwasher-Safe Stainless Steel Filters
Exhaust Duct
Duct Required
36"
In-Cabinet
Electronic
Down
1600
10"
External
Infinite Speed
Yes
External
3-1/4" x 10"
SPECIFICATIONS
Product Dimensions –
Height (Including 10" Rise)
Width
Depth
Voltage Rating
Connected Load (kW Rating) @ 120 Volts‡
Amps @ 120 Volts
Motor Power Cord Location
Shipping Weight (Approx.)
40"
36"
9-27/32"
120V /60 Hz /15A or 20A
1.0
8.0
Bottom Right
55 Lbs.
‡ For
use on adequately wired 120V, dedicated circuit having 2-wire service with a separate
ground wire. Appliance must be grounded for safe operation.
* Remote Exhaust Blower (PN# 5304444802) included with vent — shipped in separate box.
NOTE: Always consult local and national electric codes. Check local building codes for
installation requirements, as they may vary per locale. Refer to Product Installation Guide
for detailed installation instructions on the web at electroluxicon.ca.
Slim Style
Specifications subject to change.
Designed to work in perfect harmony
with your 36" gas or electric cooktop.
Infinite-Speed Blower Control
The ultraquiet blower allows you to dial
in the precise airflow needed.
10"-High Intake
When activated, the downdraft vent rises 10"
to capture even the most stubborn cooking
odors. Can be vented through wall or roof.
Cleans Your Air Quietly
The strong, powerful performance of this
1600 CFM system matches your cooktop’s
output and aromas vanish into thin air.
Blower is included with the downdraft vent.
electroluxicon.ca
Downdraft Vent
E36DD75ESS
Studwall
Wallboard
3
/4" max.
backsplash
thickness
1
/4" min.
2 1/8"
Cooktop/
Range
3"
1 15/16"
9
/32"
2 13/16"
Vent unit
Motor cover
36" Downdraft Vent Specifications
• Installing a Downdraft Vent in combination with any gas cooking surface will
• Voltage Rating – 120V / 60 Hz / 15 or 20 Amps
• Connected Load (kW Rating) @ 120 Volts = 1.0 kW (For use on adequately
wired 120V, dedicated circuit having 2-wire service with a separate ground
wire. Appliance must be grounded for safe operation.)
affect optimum burner efficiency.
• Downdraft Vents can NOT be used in combination with any cooktop backsplash.
• Downdraft Vent model E36DD75ESS is approved to be used in combination
with Electrolux ICON® Drop-In Cooktop models E36EC65ESS, E36EC70FSS,
E36IC75FSS, E36IC80ISS, E36GC70FSS, E36GC65ESS; and Electrolux ICON®
Slide-In Cooktop models E36EC75DSS, E36EC75ESS, E36EC75HSS,
E36GC75DSS, E36GC75ESS, E36GC75GSS, E36GC76EPS and E36GC76GPS.
(For detailed countertop preparation, refer to Drop-In and Slide-In
Cooktop / Downdraft Vent Countertop Preparation pages on web.)
• Amps @ 120 Volts = 8.0 Amps
• Do not use same circuit as cooktop.
• Always consult local and national electric codes. Check local building codes
for installation requirements, as they may vary per locale.
• Vent must be installed in vertical orientation only.
• Proper combination installation of Electrolux ICON® Downdraft Vent model
• Vent unit outside of building only.
E36DD75ESS and approved 36" Gas Slide-In Cooktop will require cooktop
power cord to be relocated to underside of unit. (For details, refer to 30" & 36"
Gas Slide-In Cooktop Power Cord Relocation Instructions on web.)
• Exhaust Duct Required – 3-1/4" x 10" (3-1/4" x 10" to round transition
duct will be needed)
• Do not use flexible duct. Round duct instead of rectangular duct recommended,
especially when elbows are required.
Remote Exhaust Blower
• 1,600 CFM remote exhaust blower (PN # 5304444802) included
• When multiple elbows are necessary, ensure a minimum of 24" of
with vent – shipped in separate box.
straight duct between any two elbows.
• Thermal breaks such as short section of nonmetallic duct, should be used
• Installation Options – roof or exterior wall mount for against-wall vent
installation and under-floor mount for island vent installation.
in areas of extreme cold.
• For most efficient airflow exhaust, use a straight run or as few elbows as possible.
• Cold weather installations should have additional backdraft damper installed.
Note: For planning purposes only. Refer to Product Installation Guide
on the web at electroluxicon.ca for detailed instructions.
Electrolux Major Appliances, N.A.
CANADA
•
5855 Terry Fox Way • Mississauga, ON L5V 3E4 • 1-800-265-8352 • electroluxicon.ca
E36DD75ESS 01/12
© 2012 Electrolux Major Appliances, NA
High standards of quality at Electrolux Major Appliances, NA mean we are
constantly working to improve our products. We reserve the right to change
specifications or discontinue models without notice.