Home Standby - 7kW - 10kW - 13kW
Air-Cooled Gas Engine Generator Sets
Continuous Standby Power Rating
Model ASPBS1CCA007 - 7kW 60Hz
Model ASPBS1CCA010 - 10kW 60Hz
Model ASPBS1CCA013 - 13kW 60Hz
INCLUDES:
• Automatic Transfer
Switch With Built-In
Emergency Load Center
• Electronic Governor (10kW and 13kW)
• Pre-wired External
Connection Box
• Flexible Fuel Line
• Composite Mounting Pad
• Pre-wired conduits
• Natural Gas or LP Gas Operation
• UL 2200 Listed to U.S. and Canadian Standards
FEATURES
ˆ
ˆ
INNOVATIVE DESIGN & PROTOTYPE TESTING are key components of
CARRIER’S success in “IMPROVING POWER BY DESIGN.” But it
doesn’t stop there. Total commitment to component testing, reliability
testing, environmental testing, destruction and life testing, plus testing
to applicable CSA, NEMA, EGSA, and other standards, allows you to
choose CARRIER with the confidence that these systems will provide
superior performance.
ˆ
SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION.
This state-of-the-art power maximizing regulation system is standard
on all models. It provides optimized FAST RESPONSE to changing
load conditions and MAXIMUM MOTOR STARTING CAPABILITY by
electronically torque-matching the surge loads to the engine.
ˆ
SINGLE SOURCE SERVICE RESPONSE from Carrier’s dealer network
provides parts and service know-how for the entire unit, from the engine
to the smallest electronic component. You are never on your own when
you own a CARRIER SYSTEM.
ˆ
CARRIER TRANSFER SWITCHES. Long life and reliability are
synonymous with CARRIER. One reason for this confidence is that the
CARRIER product line includes its own transfer systems and controls
for total system compatibility.
TEST CRITERIA:
> PROTOTYPE TESTED
> SYSTEM TORSIONAL TESTED
> NEMA MG1-22 EVALUATION
> MOTOR STARTING ABILITY
INSTALLATION
SYSTEM
UNIT
MICROPROCESSOR CONTROL
TRANSFER
SWITCH
GENERATOR
ENGINE
HOME STANDBY SPECIFICATIONS
Home Standby - 7kW - 10kW - 13kW
•Durable OHVI Design
Maximizes engine “breathing” for increased fuel efficiency. Cylinder walls run cooler, reducing
oil consumption. Because heat is the primary cause of engine wear, the OHVI has a significantly
longer life than competitive engines.
•”Spiny-lok” cast iron cylinder walls
Rigid construction and added durability provide long engine life.
•Electronic ignition, spark advance and
compression release
These features combine to assure smooth, quick starting every time.
•Full pressure lubrication system
Superior lubrication to all vital bearings means better performance, less maintenance and significantly
longer engine life.
•Low oil pressure shutdown system
Superior shutdown protection prevents catastrophic engine damage due to low oil.
•High temperature shutdown
Prevents damage due to overheating.
•Revolving field
Allows for smaller, light weight unit that operates 25% more efficiently than a revolving armature generator.
•Skewed stator
Produces a smooth output waveform for compatibility with electronic equipment.
•Displaced phase excitation
Maximizes motor starting capability. Provides more surge capability than brushless generator designs.
•Automatic voltage regulation
Regulates the output voltage to ±2% prevents damaging voltage spikes.
•UL 2200 Listed
For your safety
•Fully Automatic
Transfers your vital electrical loads to the energized source of power.
•Remote Mounting
Mounts near your existing distribution panel for simple, low cost installation.
•UL Listed
For your safety
•Manual/Auto/Off switch
Selects the operating mode.
•Utility voltage sensing
Constantly monitors utility voltage, setpoints 60% dropout, 70% pick-up, of standard voltage.
•Utility interrupt delay
Prevents nuisance start-ups of the engine, set point approximately 10 seconds.
•Engine warm-up
Ensures engine is ready to assume the load, setpoint approximately 10 seconds.
•Engine cool-down
Allows engine to cool prior to shutdown, setpoint approximately 1 minute.
•Seven day exerciser
Operates engine to prevent oil seal drying and damage between power outages.
•Timed Trickle Battery charger
Maintains battery amperage to insure starting.
•Main Line Circuit Breaker
Protects generator from overload.
•Weather protective enclosure
Ensures protection against mother nature. Hinged key locking roof panel for security.
Lift-out front for easy access to all routine maintenance items. Electrostatically applied
textured epoxy paint for added durability.
•Enclosed critical grade muffler
Quiet, critical grade muffler is mounted inside the unit to prevent injuries.
•Small, compact, attractive
Makes for an easy, eye appealing installation.
•Pre-wired External Connection Box
Easy Installation - Virtually all hardware included, plus step-by-step photographed Installation Guide.
•1’ Flexible Fuel Line
•Composite Mounting Pad
•Pre-wired conduits
•UL Listed wire nuts
Home Standby - 7kW - 10kW - 13kW
GENERATOR
Model ASPBS1CCA007 (7kW)
Rated Maximum Continuous Power Capacity (LP)................................... 7,000 Watts*
Rated Maximum Continuous Power Capacity (NG)...................................6,000 Watts*
Rated Voltage................................................................................................120/240
Rated Maximum Continuous Load Current
120 Volts ................................................................................................58.3 LP/50.0 NG
240 Volts ................................................................................................29.2 LP/25.0 NG
Main Line Circuit Breaker ............................................................................. 30 Amp
Phase ................................................................................................................. 1
Number of Rotor Poles ....................................................................................... 2
Rated AC Frequency ........................................................................................60Hz
Power Factor .......................................................................................................1
Battery Requirement (not included) .......................................................... Group 26
12 Volts and
350 Cold-cranking
Amperes Minimum
Unit Weight ................................................................................................ 336 Pounds
Dimensions (L” x W” x H”)....................................................................... 48 x 24 x 28-1/4
Sound output in dB(A) at 23 ft. with generator operating at full load................ 68
ENGINE
Model ASPBS1CCA007 (7kW)
Model ASPBS1CCA010 (10kW) Model ASPBS1CCA013 (13kW)
10,000 Watts*
9,000 Watts*
120/240
13,000 Watts*
13,000 Watts*
120/240
83.3 LP/75.0 NG
41.7 LP/37.5 NG
45 Amp
1
2
60Hz
1
Group 26
12 Volts and
525 Cold-cranking
Amperes Minimum
375 Pounds
48 x 24 x 28-1/4
70.5
108.3 LP/108.3 NG
54.1 LP/54.1 NG
55 Amp
1
2
60Hz
1
Group 26
12 Volts and
525 Cold-cranking
Amperes Minimum
426 Pounds
48 x 24 x 28-1/4
71.5
Model ASPBS1CCA010 (10kW) Model ASPBS1CCA013 (13kW)
Type of Engine........................................................................................
OHVI
OHVI V-TWIN
OHVI V-TWIN
Number of Cylinders........................................................................................... 1
2
2
Rated Horsepower................................................................................. 14.5 @ 3,600 rpm
18 @ 3,600 rpm
30 @ 3,600 rpm
Displacement................................................................................................... 410cc
530cc
992cc
Cylinder Block........................................................................................ Aluminum w/Cast
Aluminum w/Cast
Aluminum w/Cast
Iron Sleeve
Iron Sleeve
Iron Sleeve
Valve Arrangement.................................................................................. Overhead Valve
Overhead Valve
Overhead Valve
Ignition System.................................................................................. Solid-state w/Magneto
Solid-state w/Magneto
Solid-state w/Magneto
Governor System......................................................................................... Mechanical
Electronic
Electronic
Compression Ratio.......................................................................................... 8.6:1
9.5:1
9.5:1
Starter............................................................................................................ 12 Vdc
12 Vdc
12Vdc
Oil Capacity Including Filter..................................................................... Approx. 1.5 Qts
Approx. 1.7 Qts.
Approx. 1.7 Qts.
Operating RPM............................................................................................... 3,600
3,600
3,600
Fuel Consumption
Natural Gas ....................cu.ft./hr.
........................................1/2 Load
66
102
156
........................................Full Load
119
156
220
Liquid Propane................ft3/hr (gal/hr)
........................................1/2 Load
30 (0.82)
46 (1.25)
57 (1.55)
........................................Full Load
54 (1.47)
70 (1.93)
80 (2.18)
Required fuel pressure to generator fuel inlet at all load ranges - 5 to 7 inches of water column for natural gas, 10 to 12 inches of water column for LP gas
CONTROLS
Mode Switch
-Auto ...............................................................................................................................................
Automatic Start on Utility failure
7 day exerciser
-Off ............................................................................................................................................
Stops unit. Power is removed
Control and charger still operate
-Manual/Test (start) ......................................................................................................................
Start with starter control, unit
stays on. If utility fails, transfer
to load takes place.
Engine Start Sequence
Cyclic cranking: 7 sec. on, 7 rest
(90 sec. maximum duration)
Engine Warm-up ..................................................................................................................................................... 10 seconds
Engine Cool-Down ..................................................................................................................................................... 1 minute
Starter Lock-out ........................................................................................................................................ Starter cannot re-engage until
5 sec. after engine has stopped.
2.5 Amp Timed Trickle Battery Charger .................................................................................................................. Standard
Automatic Voltage Regulator w/Overvoltage Protection ............................................................................................ Standard
Automatic Low Oil Pressure Shutdown ..................................................................................................................... Standard
Overspeed Shutdown ............................................................................................................................................ Standard, 72Hz
High Temperature Shutdown ..................................................................................................................................... Standard
Overcrank Protection ................................................................................................................................................. Standard
Safety Fuse ............................................................................................................................................................... Standard
Rating definitions - Standby: Applicable for supplying emergency power for the duration of the utility power outage. No overload capability is available for this rating. (All ratings in accordance with
BS5514, ISO3046 and DIN6271). * Maximum wattage and current are subject to and limited by such factors as fuel Btu content, ambient temperature, altitude, engine power and condition, etc. Maximum
power decreases about 3.5 percent for each 1,000 feet above sea level; and also will decrease about 1 percent for each 12° C (10° F) above 15.5° C (60°F).
Home Standby - 7kW - 10kW - 13kW
TRANSFER SWITCH &
EMERGENCY LOAD CENTER
No. of Poles
Current Rating (amps
Voltage Rating (VAC)
Utility Voltage Monitor (fixed)
-Pick-up
-Dropout
Return to Utility
Exerciser weekly for 12 minutes
UL Listed
Dimensions (H” x W” x D”)
Total of Pre-wired Circuits
No. 15A 120V
No. 20A 120V
No. 20A 240V
No. 30A 240V
No. 40A 240V
Circuit Breaker Protected
Available RMS Symmetrical
Fault Current @ 250 Volts
Model ASPBS1CCA007
(7kW)
2
100
250
Model ASPBS1CCA010
(10kW)
2
100
250
Model ASPBS1CCA010
(13kW)
2
100
250
70%
60%
approx. 13 sec.
Standard
Standard
26.5 x 12.5 x 7
8
5
1
1
-
70%
60%
approx. 13 sec.
Standard
Standard
26.5 x 12.5 x 7
10
3
3
1
1
-
70%
60%
approx. 13 sec.
Standard
Standard
26.5 x 12.5 x 7
12
5
3
1
1
10,000
10,000
10,000
Mechanical Dimensions (in inches)
Current
No. of
Height
Rating
Poles
H1
H2
100 UL Listed
2
26.5
29.25
W2
W1
H1
Terminal Wire Ranges
ATS Rated Amps
Switch Terminal
100A 2-Pole UL
1 x 1/0-12
H2
Width
W1
W2
8.14
12.5
Neutral Lug/Stud
1 x 3/8-16 Stud
Depth
Transfer Switch Features
• Electrically operated,
mechanically-held contacts for
fast, positive connections.
• Rated for all classes of load,
100% equipment rated, both
inductive and resistive.
• 2 pole, 250 VAC contactors.
• 160 millisecond transfer time.
• Dual coil design.
• Main contacts are silver plated
or silver alloy to resist welding
and sticking.
• Nema 1 enclosure is standard
on the 100 amp switch.
7
Ground Lug
1 x 2/0-14
Conduit sizes
vary depending
on model #
CARRIER, INC.
CarrierAC7.10.13kW 9.06
•
7310 WEST MORRIS STREET • INDIANAPOLIS, IN 46231
W E B S I T E : w w w. c a r r i e r. c o m
CATALOG NO. ASPBS07-1SS