Agilent Technologies
TOYO Corporation
Solutions Partner Catalog
- EMC Measurements -
Solutions
Table of Contents
About TOYO .........................................................................................................................................................3
EMI Measurement System ................................................................................................................................4
TEM-wave Large-bandwidth Transmission Line System G-CELL ...............................................................6
GTEM CELL System ............................................................................................................................................8
Common Mode Noise Measurement System TS1000 ................................................................................10
Radiated/Conducted Immunity Test System ...............................................................................................12
Oscilloscope for Immunity Pulse Waveform Observation..........................................................................14
SVSWR Measurement System .......................................................................................................................15
Solutions
2
About TOYO Corporation
TOYO Corporation, as an expert in measurement technology, has been
proactively breathing fresh life into the sunrise industry such as energy
and environment, along with its mainstream business including
electromagnetic interference measurement and communication
measurement. Striving for a name trusted in the market innovation
technology, not only a measurement technology provider, we, at TOYO,
redouble our efforts to expand the laboratories, impart technical
knowledge, improve the training facilities and enrich technical training for
employees.
In recent years, TOYO has been delivering carefully needs-matched
solutions to each customer through self-developed system products and
will be committed to promptly catering to the demand for technological
innovation with a reinforced development group.
“Measurement” technology constitutes
the mainstay of all businesses -
this is what TOYO believes.
Technology Interface Center
3
EMI Measurement System
- CISPR-approved system EMI measurement system best suited to customer needs
Overview
The electronics industry moves toward the digitalization
and mobilization of equipment with higher density
packaging, making the determination of noise source
and EMC control more challenging.
There are increasing demands to expand upper limited
frequency, adhere to frequently-revised standards, and
acquire and store data on more complex noise to the
greatest extent possible.
TOYO’s 30 years of technical expertise has trickled down
to its automatic systems based on impressive records of
supplying hundreds of systems to various businesses
from public test laboratories through commercial EMC
test houses.
TOYO’s time-proven systems offer the user a wide choice
of options, from full compliance fully-automatic
measurement to preliminary simplified measurement.
Measurement
room
Spectrum analyzer/
EMI test receiver
RF se
Preamplifier
[max. 1 GHz]
Optical fiber cable
Mast/ Table controller
Basic measurement functions
• Capable of acquiring spectrum and QP detector measurement
with a single click.
• Endowed with functions effective for manual measurements.
• Capable of exporting data.
System controller
Auto measurement software
Clamp controller
Software
EP7 Series (3D display with a detailed noise analysis function)
• EP7/RE type: Radiated noise weighting and measurement
software
• EP7/CE type: Terminal noise weighting and measurement
software
EP5 Series (With a standard noise analysis function)
• EP5/RE type: Radiated noise measurement software
• EP5/CE type: Terminal noise measurement software
• EP5/RFP type: Noise power measurement software
• EP5/RSE type: Radiated spurious emission measurement
software
Applicable standards
Consumer product standards
• CISPR
• EN
• FCC
• VCCI
Automotive standards
• 2004/104/EC
• SAE
• CISPR25
• JASO
Preamplifier
[1-8 GHz]
RF cable
GPIB cable
Optical fiber cable
USB cable
CISPR-compliant EMI test receiver with an integrated preselector
Wireless Application standards
• TS51.010-1, TS34.121 (3GPP)
• Cellular phones (GSM, WCDMA)
• EN300 328, EN301 893 (ETSI)
N9038A MXE EMI receiver
Frequency: 20 Hz – 8.4/26.5 GHz
4
EMI Measurement System TS9949 Series
High-frequency light converter E18000 – E6000
Converting from coaxial cables to optical fiber
Radio anechoic
room
E18000 – E6000 converters are designed to
transmit RF signals captured by an antenna in
the form of light energy. Fiber-optic transmission
offers low loss and excellent noise tolerance as
compared with coaxial cables, realizing a high
sensitivity radiant emission measurement
system.
Radiated noise measurement setup
Biconical antenna
[30 MHz-300 MHz]
elector
Antenna mast
Log periodic antenna
[300 MHz-1 GHz]
(Biconilog antenna)
[30 MHz-1 GHz]
Horn antenna
[1 GHz-6 GHz]
Features
• Frequency range Model E18000: 1 G-18 GHz
Model E6000: 30 M-6 GHz
• Capable of highly-sensitive measurement by
low-loss transmission
• Ideally suited for switching the EMI
measurement transmission line with excess
of 1 GHz.
• Long transmission distance: Min. 100 meters
EUT
HAP antenna
[6-18 or 40 GHz]
EUT table
Turntable
Terminal noise measurement setup
Radio anechoic room
LISN
ISN
Direct-coupled
E18000
head part
High-frequency antenna
Noise power measurements setup
(Auxiliary clamp)
Measurement room
Absorbing clamp
Optical fiber cable
RF cable
Clamp travel gear
EMI test receiver
Shield room or radio anechoic room
Pre-compliance spectrum analyzer X Series
N9030A PXA signal analyzer
Frequency: 3 Hz – Max. 50 GHz
FCC standard (1-40 GHz)-compatible model
N9020A MXA signal analyzer
Frequency: 20 Hz – Max. 26.5 GHz
CISPR standard (Min. 1 GHz)-compatible model
5
TEM-wave Large-bandwidth Transmission
Line System G-CELL
Designed for EMI measurement and analysis and assessment of radiated
immunity test
Overview
TOYO’s G-CELL is a cubic cell upgraded from TEM
CELL, enabling easy radiated EMI measurement and
immunity test of EUTs in the transmission line
installed on the floor.
User-friendly G-CELL is favorable for immunity
control and preliminary measurements before
authentication tests in a radio anechoic room and
open site.
Features
• Capable of easy EMI measurement with the spectrum
analyzer.
• Enables radiated immunity test assuring consistency.
• Large opening design allowing easy EUT installation.
• Customizable power/signal line filters
Applications
• Radiant emission measurement
• Radiant immunity test
Software
• EP5/ME type: Simplified EMI measurement software
• IM5/RS type: Radiated immunity test software
Specifications
• Frequency range: 10 k-1 GHz (2 GHz)
• Max. input power: 150 W (Type N connector)
• Dimensions: 70×70×70 cm (protrusion excluded)
• Applicable EUT size: 40×40×40 cm
• Shielding performance: Min. 70 dB
G-CELL
6
Connection diagram for radiant emission measurement
G-CELL
310N preamplifier
N9010A EXA signal analyzer
(recommended)
Standard components
Model
Equipment
G-CELL
TEM-wave large-bandwidth transmission line system
EP5/ME
Simplified EMI measurement software
N9010A EXA
Signal analyzer (9 k-3 GHz)
310N
Preamplifier
50  termination
Computer, a set of cables (RF, GPIB)
Connection diagram for radiated immunity test
Electric field sensor
N5181A MXG signal generator
(recommended)
RF power amplifier
G-CELL
Standard components
Model
Equipment
G-CELL
TEM-wave large-bandwidth transmission line system
IM5/RS
Radiated immunity test software
N5181A
Signal generator (100 k-3 GHz)
power amplifier
Electric field sensor
50  termination
Computer, a set of cables (RF, GPIB)
7
GTEM CELL
Excellent for analysis and assessment of EMI and immunity control
Overview
Our GTEM CELL is apt for EMC applications,
antenna/ magnetic field probe and cellular phone
tests in tandem with an upgrade frequency band
from TEM (Transverse Electro Magnetic) CELL. The
extended frequency band also lends itself to part
sorting and measurements.
Features
• Stable shielded environment for EMI measurement and
immunity test
• Compliant with the IEC/EN61000-4-20 and FCC ANSI C63.4
standards.
• Designed for broad spectrum (DC-20 GHz).
• Offers a rich lode of GTEM CELL models (septum height
ranging from 250 mm to 2000 mm)
• Outstanding VSWR over the entire frequency band
• Customizable power/signal line filters
GTEM CELL
Applications
• Radiant emission measurement
• Radiant immunity test
Software
• EP5/ME type: Simplified EMI measurement software
• IM5/RS type: Radiated immunity test software
Specifications
GTEM250
GTEM500
GTEM750
GTEM1000
Septum height (mm)
250
500
750
1000
Dimensions (m)
1.25×0.65×0.45
2.95×1.48×1.61
3.95×2.02×1.95
4.95×2.54×2.30
Dimensions of test product (m)
0.15×0.15×0.08
0.30×0.30×0.15
0.45×0.45×0.22
0.60×0.60×0.30
Max. input power (w)
50 W
100 W
200 W
1000 W
GTEM1250
GTEM1500
GTEM1750
GTEM2000
Septum height (mm)
1250
1500
1750
2000
Dimensions (m)
5.95×3.06×2.52
6.95×3.58×2.55
7.95×4.10×2.90
8.95×4.62×3.24
Dimensions of test product (m)
0.70×0.70×0.38
0.85×0.85×0.45
1.00×1.00×0.50
1.15×1.15×0.60
Max. input power (w)
1000 W
1000 W
1000 W
1000 W
8
Connection diagram for radiant emission measurement
GTEM CELL
310N preamplifier
N9010A EXA signal analyzer
(recommended)
Standard components
Model
Equipment
GTEM CELL
EP5/ME
Simplified EMI measurement software
N9010A EXA
Signal analyzer (9 k-3 GHz)
310N
Preamplifier
Computer, a set of cables (RF, GPIB)
Connection diagram for radiated immunity test
Electric field sensor
GTEM CELL
N5181A MXG signal generator
(recommended)
RF power amplifier
Standard components
Model
Equipment
GTEM CELL
IM5/RS
Radiated immunity test software
N5181A
Signal generator (100 k-3 GHz)
Power amplifier
Electric field sensor
Computer, a set of cables (RF, GPIB)
9
Common Mode Noise Measurement
System TS1000
Easy noise suppression achieved in
common mode noise measurement
Overview
TOYO’s savvy has made it possible to attain the
accuracy of common mode noise measurement
closest to that of spurious noise measurement in a
radio anechoic room, using the Workbench Faraday
Cage (IEC61967-5), an EMC performance
assessment method of a semiconductor. Sporting
reproducibility superior to conventional
measurements in a radio anechoic room, our TS1000
is effective in EMI control during the product
development stage.
Inside of FC-1000
Features
• Unsusceptible to radiated noise, delivering high data
reproducibility.
• Capable of measurements in a low-noise floor level.
• Speedy, fuss-free measurements as compared with noise
measurements in a radio anechoic room
• Allows common mode noise measurements in any office
environments.
Applications
• Radiant emission measurement
EP6/FC Faraday gauge measurement software
FC-1000 Main Specifications
• Mmeasuring frequency range: 30-1000MHz
• Max. outer dimensions: 950mm (L) ×780mm (w) ×220mm (H)
• Weight: 29.2kg
• I/O voltage range: -48-48VDC
• I/O current range: 0-2ADC
• Number of power input terminals: 6 systems
• Number of signal I/O terminals: 3 systems
Standard components
* No AC input and output enabled
Model
Equipment
FC-1000
Faraday cage
EP6/FC
Faraday cage measurement software
N9010A EXA
Signal analyzer (9 k-3.6 GHz)
310N
Preamplifier
Computer, a set of cables (RF, GPIB)
Connection diagram
RF
FC-1000 system
RF
GPIB
N9010A EXA signal analyzer
310N preamplifier
10
PC
11
Radiated/Conducted Immunity Test System
- Compliant with international and company standards Immunity test system best suited to customer needs
Overview
TOYO offers a valuable test system to assess
electromagnetic interference in electronic
equipment. Installed with Radiated Immunity Test
Software IM5, our immunity test system
automatically controls the signal generator, power
amplifier system, electric field sensor, power meter
and antenna mast. It also supports outputting and
saving of test results.
Measurement
room
Measuring instrument rack
Signal generator
Power sensor
F1
Power meter
F2
F3
R1 R2
R23
Directional coupler
F1
R1
F2
R2
Basic measurement functions
• Electric field uniformity measurement
• System linearity testing
• Electric field reference measurement/ Electric field check
• Immunity test
• Display of measured results
• Report generation
RF selector
F3
R3
(Selector controller)
(Signal generator)
Software
• IM5/RS type: Radiated immunity test software
• IM5/CS type: Conducted immunity test software
• VI5/RS type: Vehicle radiated immunity test software
RF amplifier
[150kHz-230MHz]
Spectrum analyzer
Directional couple
Power meter
System controller
Applicable standards
Radiated immunity automatic test software
Conducted immunity automatic test softwar
Consumer product standards
• IEC61000-4-3,6
• CISPR24
• EN
Optical GPIB converter
Optical fiber cable
RF cable
Optical USB converter
GPIB cable
Optical fiber cable
Automotive standards
• 2004/104/EC
• ISO11452-1/2
• SAE
• JASO
• GM/Ford standards (radar pulse)
• Standards in other auto manufacturers
USB cable
Recommended signal generator
MIL standards
Standards for medical devices
N5181A/ N5183A
MXG signal generator
12
er
re
Immunity Measurement System TS5000/6000 Series
RF power amplifier TA series (10 kW/5 kW)
RF power amplifier TA series is a solid state (semiconductor device)-laden high power amplifier,
delivering output linearity and stability as fundamental performance. TA series is designed for high
reliability and quality.
Radio anechoic
room
Radiated immunity test setup
Log periodic antenna
[80MHz-1GHz]
EUT
Features
• 10 kW of high power output (7 kW@1 dB comp.)
• Easy maintainability through RF unit
replacement
• Equipped with the internal data storage
function which is capable of easy cause
analysis of a malfunction.
Antenna mast
Stacked log periodic antenna
[1GHz-6GHz]
EUT table
(Horn antenna)
[1GHz-2.5GHz]
Electric field sensor
Specifications
(Horn antenna)
[2.5GHz-6GHz]
Model
Sensor mast
Frequency
10 kW
6 k-10 kW
TA0112-5K
5 kW
4 k-5 kW
10 k-50 MHz
50 M-200 MHz
Conducted immunity test setup
Attenuator
Termination
To power
supply
150 :/50 :
Conversion adapter
EUT
CDN
To monitoring spectrum analyzer
Shield room or radio anechoic room
TA0112-10k
Recommended power meters
P Series Power Meter
N1912A
EPM Series Power Meter
N1914A
13
Output
TA0112-10K 10 k-100 MHz
100 M-225 MHz
Oscilloscope for Immunity Pulse
Waveform Observation
Software-controlled instantaneous waveform check
Overview
The IEC-defined immunity standards provides for a
pulse shape check in calibration and daily
inspection. ESD waveforms which have the quick
leading edge of sporadic pulse especially require
the utilization of a wide band oscilloscope.
Features
• Designed to meet a sample speed and frequency band
• Software-controlled automatic waveform measurement and
report generation
TESEQ Model NSG437
Discharge voltage 200 V-30 kV (IEC61000-4-2-compatible)
Applications
• Waveform calibration and daily inspection
Standard components
Model
Equipment
MSO9000 Series
Oscilloscope
MD103
ESD waveform observation target
(IEC61000-4-2)
CAS3025
EFT/ burst observation attenuator
(IEC61000-4-4)
MD200
Surge waveform observation probe
(IEC61000-4-5)
MD300
Surge waveform observation probe
(IEC61000-4-5)
Recommended oscilloscope
MSO9000 Series oscilloscope
ESD oscilloscope waveform
14
SVSWR Measurement System
Network analyzer delivering high-speed SVSWR measurement!!
Overview
With 1-6 GHz radiant emission measurement
defined by EN55022 and VCCI standards as of
October 1, 2011, a radio anechoic room and test site
for EMC must meet all the requirements of NSA
regulation (max. 1 GHz) and SVSWR regulation
(min. 1 GHz).
This system is useful to dramatically accelerate test
site measurement.
Receiving antenna
Radio wave absorber
Transmitting antenna
Transmitting antenna positioner
Network analyzer
Features
• Equipped with the network analyzer and positioner that offer
enhanced speed.
• Strong lineup of antennas
PCI–GPIB
Site SVSWR measurement software
Computer for measurement
SVSWR measurement system
Applications
• Radio anechoic room measurement (min. 1 GHz)
Transmitting antenna
Standard components
Model
Equipment
PP700
Antenna positioner, software
E5071C
ENA network analyzer
3183
Transmitting antenna (1 G-18 GHz)
R1– R6
Receiving antenna
C1– C6
F1– F6
Test
volume
d
Computer, a set of cables (RF, GPIB)
L1– L6
Measurement position
Recommended network analyzer
E5071C ENA network analyzer
ETS Lindgren 3183 (1-18 GHz)
15
About Agilent Technologies
Agilent Technologies is the world's largest company that designs
and manufactures measurement instruments and equipment
while focusing on communication, electronics, life science and
chemical analysis markets. Operating in over 100 countries,
Agilent has expanded availability with a staff of 18,700 worldwide
and sales stood at around $6.6 billion (¥500 billion) in October
2011.
Company History Timeline
1939
1943
1951
1960
1963
1964
1970
1973
1974
1982
1983
1992
1999
2009
Hewlett-Packard Company (HP) founded in Silicon
Valley, California, by Bill Hewlett and Dave Packard
Audio oscillator invented and ordered to be used in the
production of the Disney movie “Fantasia”
Signal generators developed. HP enters the microwave
field.
Frequency counter developed.
Sampling oscilloscope developed.
Incorporated enterprise “Yokogawa Hewlett-Packard”
formed in Japan.
Cesium-beam atomic clock developed.
Microwave network analyzer developed.
Logic analyzer developed.
The electronics industry adopts the HP-IB (GPIB)
interface as an international standard.
HP receives Deming Prize (Quality Control Award) in
Japan.
Semiconductor parametric test system introduced in
Japan.
Optical spectrum analyzer developed.
HP announces strategic realignment to demerge the
Computer Division and Measurement Division, and the
measurement company launches operations as Agilent
Technologies. Initial public stock raises $2.1 billion and
breaks records as the largest IPO in Silicon Valley
history.
Agilent Technologies celebrates 10th anniversary and
70th anniversary of HP foundation.
Contact Agilent
Americas
United States
Tel: (800) 829 4444
Canada
Tel: (877) 894 4414
Latin America
Brazil
Tel: (11) 4197 3500
Mexico
Tel: 01800 5064 800
Asia Pacific
Australia
Tel: 1 800 629 485
China
Tel: 800 810 0189
Hong Kong
Tel: 800 938 693
India
Tel: 1 800 112 929
Japan
Tel: 0120 (421) 345
Korea
Tel: 080 769 0800
Malaysia
Tel: 1 800 888 848
Singapore
Tel: 1 800 375 8100
Taiwan
Tel: 0800 047 866
Other Asia Pacific Countries
Tel: (65) 375 8100
Europe & Middle East
Belgium
Tel: 32 (0) 2 404 93 40
Denmark
Tel: 45 70 13 15 15
Finland
Tel: 358 (0) 10 855 2100
Audio Oscillator (1939)
In 1939 HP was formed in this small
garage. The iconic garage is designated
as California State Historical Building
#976 for the “cradle of Silicon Valley”.
Brazil, Canada, Mexico, Puerto Rico, United States, Australia, China, Hong Kong, India, Korea, Malaysia, Singapore,
Thailand, Taiwan, Austria, Belgium, Switzerland, Germany, Denmark, Spain, Finland, France, United Kingdom,
Ireland, Israel, Italy, Netherlands, Russia, Sweden, Japan
Japan headquarters (Hachioji Office)
France
Tel: 0825 010 700*
* 0.125 Euro/minute
Germany
Tel: 49 (0) 7031 464 6333
Ireland
Tel: 1890 924 204
Israel
Tel: 972 3 9288 504/544
Italy
Tel: 39 02 92 60 8484
Netherlands
Tel: 31 (0) 20 547 2111
Spain
Tel: 34 (91) 631 3300
Sweden
Tel: 0200 88 22 55
United Kingdom
Tel: 44 (0) 131 452 0200
For Other Unlisted Countries:
www.agilent.com/find/contactus
Headquarters in Santa Clara,
CA, United States
Contents in this catalog are subject to change without notice.
Please inquire about details when placing an order.
©Agilent Technologies. Inc. 2012
Published in Japan, April 26, 2012
5990-9819EN
0000-08DEP