Selection Guide
Meter Selection Guide
pH Meter Quick Guide
EUTECH
INSTRUMENTS
Meter Selection Guide
pH Meter Quick Guide
Models
Parameters
pH Range
Accuracy
Cal.
pH Buffer Sets
Points
GLP Memory
Temperature Housing
Page
Communication
Display
Rating
No.
Pocket Testers
PCSTestr 35
PCTestr 35
PTTestr 35
pHTestr 30
pHTestr 20
pHTestr 10
EcoTestr pH 2
pHTestr 10BNC
pH Spear
Handheld Meters
CyberScan PCD 650
CyberScan PC 650
CyberScan PD 650
pH/Conductivity/TDS/
Salinity/ºC/ºF
pH/Conductivity/ºC/ºF
pH/TDS/ºC/ºF
pH/ºC/ºF
pH
pH
pH
pH/ºC/ºF
pH/ºC/ºF
pH/ORP/Ion/
Conductivity/TDS/
Salinity/Resistivity/
Dissolved Oxygen/ºC/ºF
pH/ORP/Ion/
Conductivity/TDS/
Salinity/Resistivity/ºC/ºF
pH/ORP/Ion/Dissolved
Oxygen/ºC/ºF
0.00 to 14.00 pH ±0.01 pH 5
USA, NIST
–
–
Yes
IP67
–
Pg 70
0.0 to 14.0 pH
0.0 to 14.0 pH
-1.00 to 15.00 pH
-1.00 to 15.00 pH
-1.0 to 15.0 pH
0.0 to 14.0 pH
-1.00 to 15.00 pH
-1.00 to 15.00 pH
±0.1 pH
±0.1 pH
±0.01 pH
±0.01 pH
±0.1 pH
±0.1 pH
±0.01 pH
±0.01 pH
USA, NIST
USA, NIST
USA, NIST
USA, NIST
USA, NIST
USA, NIST
USA, NIST
USA, NIST
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
Yes
Yes
Yes
–
–
–
Yes
Yes
IP67
IP67
IP67
IP67
IP67
IP67
IP67
IP67
–
–
–
–
–
–
–
–
Pg 70
Pg 70
Pg 16
Pg 16
Pg 16
Pg 17
Pg 18
Pg 18
-2.000 to
20.000 pH
±0.002 pH 6
USA, NIST, DIN,
PWB, Custom
Yes
500
Yes
IP67
LED RS232C, IrDA Pg 72
-2.000 to
20.000 pH
±0.002 pH 6
USA, NIST, DIN,
PWB, Custom
Yes
500
Yes
IP67
LED RS232C, IrDA Pg 73
Yes
500
Yes
IP67
LED RS232C, IrDA Pg 73
Yes
500
Yes
IP67
LED RS232C, IrDA Pg 22
Yes
500
Yes
IP67
LED RS232C, IrDA Pg 22
Yes
500
Yes
IP67
LED RS232C, IrDA Pg 22
Yes
–
–
–
–
–
–
50
16
100
50
–
–
–
Yes
Yes
Yes
Yes
Yes
Yes
Yes
IP67
IP67
IP54
IP54
IP54
IP54
IP54
–
–
RS232C
–
–
–
–
Internet/intranet,
RS232C, USB,
Pg 79
IrDA, SD card
-2.000 to
20.000 pH
-2.000 to
20.000 pH
-2.000 to
20.000 pH
5
5
3
3
3
3
3
3
±0.002 pH 6
USA, NIST, DIN,
PWB, Custom
USA, NIST, DIN,
PWB, Custom
USA, NIST, DIN,
PWB, Custom
USA, NIST, DIN,
PWB, Custom
USA, NIST, DIN
USA
USA, NIST, DIN, PWB
USA, NIST
USA, NIST, PWB
USA, NIST, PWB
USA, NIST, PWB
CyberScan pH 620
pH/ORP/Ion/ºC/ºF
CyberScan pH 610
pH/ORP/ºC/ºF
CyberScan pH 600
pH/ORP/ºC/ºF
-2.00 to 20.00 pH ±0.01 pH 6
CyberScan pH 310
CyberScan pH 300
CyberScan pH 110
CyberScan pH 11
Ion 6+
pH 6+
pH 5+
Bench Meters
pH/ORP/ºC/ºF
pH/ORP/ºC
pH/ORP/ºC/ºF
pH/ORP/ºC
Ion/pH/ORP/ºC
pH/ORP/ºC
pH/ºC
-2.00 to 16.00 pH
-2.00 to 16.00 pH
-2.00 to 16.00 pH
-2.00 to 16.00 pH
0.00 to 14.00 pH
0.00 to 14.00 pH
0.00 to 14.00 pH
±0.01 pH
±0.01 pH
±0.01 pH
±0.01 pH
±0.01 pH
±0.01 pH
±0.01 pH
-2.000 to
20.00 pH
±0.002 pH 5
USA, NIST, Euro, Custom Yes
1000 per
Yes
parameter
–
-2.000 to
20.00 pH
±0.002 pH 5
USA, NIST, Euro, Custom Yes
1000 per
Yes
parameter
–
-2.000 to
20.00 pH
±0.002 pH 5
USA, NIST, Euro, Custom Yes
1000 per
Yes
parameter
–
-1.999 to
19.999 pH
±0.002 pH 6
USA, NIST, Euro, Custom Yes
500
Yes
–
RS232C
Pg 81
-2.00 to
16.00 pH
±0.01 pH 5
USA, NIST
100
Yes
–
–
Pg 82
pH/ORP/Ion/
Conductivity/TDS/
CyberScan PCD 6500 Salinity/Resistivity/
Dissolved Oxygen/
BOD/OUR/SOUR/ºC/ºF
pH/ORP/Ion/
CyberScan PC 6500 Conductivity/TDS/
Salinity/Resistivity/ºC/ºF
pH/ORP/Conductivity/
CyberScan PC 6000 TDS/Salinity/
Resistivity/ºC/ºF
pH/ORP/Ion/
PC 2700
Conductivity/TDS/
Salinity/Resistivity/ºC/ºF
pH/ORP/Conductivity/
PC 700
TDS/ºC/ºF
±0.002 pH 6
±0.002 pH 6
6
5
6
5
3
3
3
–
Pg 23
Pg 23
Pg 24
Pg 24
Pg 25
Pg 25
Pg 25
Internet/intranet,
RS232C, USB,
Pg 80
IrDA, SD card
Internet/intranet,
RS232C, USB,
Pg 80
IrDA, SD card
Internet/intranet,
RS232C, USB,
Pg 28
IrDA, SD card
Internet/intranet,
RS232C, USB,
Pg 28
IrDA, SD card
CyberScan pH 6500
pH/ORP/Ion/ºC/ºF
-2.000 to
20.000 pH
±0.002 pH 5
USA, NIST, Euro, Custom Yes
1000 per
Yes
parameter
–
CyberScan pH 6000
pH/ORP/ºC/ºF
-2.000 to
20.000 pH
±0.002 pH 5
USA, NIST, Euro, Custom Yes
1000 per
Yes
parameter
–
Ion 2700
pH/ORP/Ion/ºC/ºF
-1.999 to 19.999 pH
6
USA, NIST, DIN, User 1,
User 2, Custom
Yes
500
Yes
–
RS232C
Pg 29
pH 2700
pH/ORP/ºC/ºF
6
USA, NIST, Custom
Yes
500
Yes
–
RS232C
Pg 30
Ion 700
pH/ORP/Ion/ºC/ºF
5
USA, NIST
–
100
Yes
–
–
Pg 31
pH 700
pH/ORP/ºC/ºF
5
USA, NIST
–
100
Yes
–
–
Pg 32
page | 04
±0.002 pH
+ 1 LSD
±0.002 pH
-1.999 to 19.999 pH
+ 1 LSD
±0.01 pH
-2.00 to 16.00 pH
+ 1 LSD
±0.01 pH
-2.00 to 16.00 pH
+ 1 LSD
Conductivity Meter Quick Guide
Models
Parameters
Conductivity Range
Accuracy
Cal. Points GLP Memory
Temperature Housing
Page
Communication
Display
Rating
No.
±1 % full scale
3 auto
3 manual
–
–
Yes
IP67
–
Pg 70
±1 % full scale
2 auto
2 manual
–
–
Yes
IP67
–
Pg 70
±1 % full scale
3 auto
3 manual
–
–
Yes
IP67
–
Pg 38
±1 % full scale
2 auto
2 manual
–
–
Yes
IP67
–
Pg 38
1
–
–
–
IP67
–
Pg 40
1
–
–
–
IP67
–
Pg 40
±1 % full scale
+ 1 LSD
4 auto
5 manual
Yes
500
Yes
IP67
LED RS232C, IrDA Pg 72
±1 % full scale
+ 1 LSD
4 auto
5 manual
Yes
500
Yes
IP67
LED RS232C, IrDA Pg 73
±1 % full scale
+ 1 LSD
4 auto
5 manual
Yes
500
Yes
IP67
LED RS232C, IrDA Pg 73
±1 % full scale
4 auto
5 manual
Yes
500
Yes
IP67
LED RS232C, IrDA Pg 43
±1 % full scale
4 auto
5 manual
Yes
500
Yes
IP67
LED RS232C, IrDA Pg 43
5
4 auto
5 manual
4 auto
5 manual
4 auto
5 manual
Yes
50
Yes
IP67
–
Pg 44
–
100
Yes
IP54
RS232C
Pg 45
–
50
Yes
IP54
–
Pg 45
–
–
Yes
IP54
–
Pg 46
Internet/intranet,
RS232C, USB,
Pg 79
IrDA, SD card
Pocket Testers
PCSTestr 35
PCTestr 35
ECTestr 11+
ECTestr 11
.. to 200.0 µS
200 to 2000 µS
2.00 to 20.00 mS
.. to 2000 µS
pH/Conductivity/ºC/ºF
2.00 to 20.00 mS
.. to 200.0 µS
Conductivity/ºC/ºF
.. to 2000 µS
.. to 20.00 mS
.. to 2000 µS
Conductivity/ºC/ºF
.. to 20.00 mS
pH/Conductivity/TDS/
Salinity/ºC/ºF
EcoTestr EC High
Conductivity
.. to 19.90 mS
EcoTestr EC Low
Handheld Meters
Conductivity
.. to 1990 µS
.. to 2.000 µS
pH/ORP/Ion/
2.000 to 300.0 µS
Conductivity/TDS/
CyberScan PCD 650
300.0 µS to 4.000 mS
Salinity/Resistivity/
4.000 to 40.00 mS
Dissolved Oxygen/ºC/ºF
40.00 to 500.0 mS
.. to 2.000 µS
pH/ORP/Ion/
2.000 to 300.0 µS
CyberScan PC 650
Conductivity/TDS/
300.0 µS to 4.000 mS
Salinity/Resistivity/ºC/ºF 4.000 to 40.00 mS
40.00 to 500.0 mS
.. to 2.000 µS
Conductivity/TDS/
2.000 to 300.0 µS
CyberScan CD 650
Salinity/Resistivity/
300.0 µS to 4.000 mS
Dissolved Oxygen/ºC/ºF 4.000 to 40.00 mS
40.00 to 500.0 mS
.. to 2.000 µS
2.000 to 300.0 µS
Conductivity/TDS/
CyberScan COND 610
300.0 µS to 4.000 mS
Salinity/Resistivity/ºC/ºF
4.000 to 40.00 mS
40.00 to 500.0 mS
.. to 2.000 µS
2.000 to 300.0 µS
CyberScan COND 600 Conductivity/TDS/ºC/ºF 300.0 µS to 4.000 mS
4.000 to 40.00 mS
40.00 to 200.0 mS
CyberScan CON 400 Conductivity/TDS/ºC/ºF .. to 199.9 mS
±1 % full scale
(±2 % above
10 mS)
±1 % full scale
±1 % full scale
CyberScan CON 110
Conductivity/TDS/ºC/ºF .. to 199.9 mS
±1 % full scale
CyberScan CON 11
Conductivity/TDS/ºC
.. to 199.9 mS
±1 % full scale
COND 6+
Conductivity/ºC
.. to 199.9 mS
±1 % full scale
.. to 500 mS
0.5 % full scale
+ LSD
5
Yes
1000 per
Yes
parameter
–
.. to 500 mS
0.5 % full scale
+ LSD
5
Yes
1000 per
Yes
parameter
–
.. to 500 mS
0.5 % full scale
+ LSD
5
Yes
1000 per
Yes
parameter
–
0.050 µS to 500.0 mS
±1 % full scale
5
Yes
500
Yes
–
RS232C
Pg 81
0.0 µS to 200.0 mS
±1 % full scale
5
–
100
Yes
–
–
Pg 82
0.5 % full scale
+ LSD
5
Yes
1000 per
Yes
parameter
–
Internet/intranet,
RS232C, USB,
Pg 50
IrDA, SD card
±1 % full scale
5
Yes
500
Yes
–
RS232C
Pg 51
±1 % full scale
5
–
100
Yes
–
–
Pg 52
Bench Meters
pH/ORP/Ion/Conductivity/
TDS/Salinity/Resistivity/
CyberScan PCD 6500
Dissolved Oxygen/BOD/
OUR/SOUR/ºC/ºF
pH/ORP/Ion/
CyberScan PC 6500 Conductivity/TDS/
Salinity/Resistivity/ºC/ºF
pH/ORP/Conductivity/
CyberScan PC 6000 TDS/ Salinity/Resistivity/
ºC/ºF
pH/ORP/Ion/
PC 2700
Conductivity/TDS/
Salinity/Resistivity/ºC/ºF
pH/ORP/Conductivity/
PC 700
TDS/ºC/ºF
CyberScan CON 6000
Conductivity/TDS/
.. to 500 mS
Salinity/Resistivity/ºC/ºF
CON 2700
Conductivity/TDS/
0.050 µS to 500.0 mS
Salinity/Resistivity/ºC/ºF
Conductivity/TDS/ºC/ºF .. µS to 200.0 mS
CON 700
Internet/intranet,
RS232C, USB,
Pg 80
IrDA, SD card
Internet/intranet,
RS232C, USB,
Pg 80
IrDA, SD card
page | 05
Selection Guide
Meter Selection Guide
Conductivity Meter
Quick Guide
Selection Guide
Meter Selection Guide
Total Dissolved Solids
Meter Quick Guide
Total Dissolved Solids Meter Quick Guide
Models
Parameters
TDS Range
Accuracy
Cal. Points GLP Memory
Temperature Housing
Page
Communication
Display
Rating
No.
±1 % full scale
2 manual
–
–
Yes
IP67
–
Pg 70
±1 % full scale
2
–
–
Yes
IP67
–
Pg 38
±1 % full scale
3
–
–
Yes
IP67
–
Pg 38
Pocket Testers
100 to 1000 ppm
1.00 to 10.00 ppt
.. to 200.0 ppm
.. to 2000 ppm
.. to 10.00 ppt
.. to 2000 ppm
.. to 10.00 ppt
PTTestr 35
pH/TDS/ºC/ºF
TDSTestr 11+
TDS/ºC/ºF
TDSTestr 11
TDS/ºC/ºF
EcoTestr TDS High
TDS
.. to 10.00 ppt
±1 % full scale
(±2 % above
5 ppt)
1
–
–
–
IP67
–
Pg 40
EcoTestr TDS Low
TDS
.. to 1990 ppm
±1 % full scale
1
–
–
–
IP67
–
Pg 40
±1 % full scale
+ 1 LSD
5
Yes
500
Yes
IP67
LED RS232C, IrDA Pg 72
±1 % full scale
+ 1 LSD
5
Yes
500
Yes
IP67
LED RS232C, IrDA Pg 73
±1 % full scale
+ 1 LSD
5
Yes
500
Yes
IP67
LED RS232C, IrDA Pg 73
±1 % full scale
5
Yes
500
Yes
IP67
LED RS232C, IrDA Pg 43
±1 % full scale
5
Yes
500
Yes
IP67
LED RS232C, IrDA Pg 43
±1 % full scale
±1 % full scale
±1 % full scale
±1 % full scale
5
5
5
5
Yes
–
–
–
50
100
50
–
Yes
Yes
Yes
Yes
IP67
IP54
IP54
IP54
–
RS232C
–
–
0.5 % full scale
+ LSD
5
Yes
1000 per
Yes
parameter
–
Internet/intranet,
RS232C, USB,
Pg 79
IrDA, SD card
0.5 % full scale
+ LSD
5
Yes
1000 per
Yes
parameter
–
0.5 % full scale
+ LSD
5
Yes
1000 per
Yes
parameter
–
±1 % full scale
5
Yes
500
Yes
–
RS232
Pg 81
±1 % full scale
5
–
100
Yes
–
–
Pg 82
0.5 % full scale
+ LSD
5
Yes
1000 per
Yes
parameter
–
Internet/intranet,
RS232C, USB,
Pg 50
IrDA, SD card
±1 % full scale
5
–
100
Yes
–
RS232C
Pg 51
±1 % full scale
5
–
50
Yes
–
–
Pg 52
Handheld Meters
.. to 2.000 ppm
pH/ORP/Ion/
2.000 to 300.0 ppm
Conductivity/TDS/
CyberScan PCD 650
300.0 ppm to 4.000 ppt
Salinity/Resistivity/
4.000 to 40.00 ppt
Dissolved Oxygen/ºC/ºF
40.00 to 500.0 ppt
.. to 2.000 ppm
pH/ORP/Ion/
2.000 to 300.0 ppm
CyberScan PC 650
Conductivity/TDS/
300.0 ppm to 4.000 ppt
Salinity/Resistivity/ºC/ºF 4.000 to 40.00 ppt
40.00 to 500.0 ppt
.. to 2.000 ppm
Conductivity/TDS/
2.000 to 300.0 ppm
CyberScan CD 650
Salinity/Resistivity/
300.0 ppm to 4.000 ppt
Dissolved Oxygen/ºC/ºF 4.000 to 40.00 ppt
40.00 to 500.0 ppt
.. to 2.000 ppm
2.000 to 300.0 ppm
Conductivity/TDS/
CyberScan COND 610
300.0 ppm to 4.000 ppt
Salinity/Resistivity/ºC/ºF
4.000 to 40.00 ppt
40.00 to 500.0 ppt
.. to 2.000 ppm
2.000 to 300.0 ppm
CyberScan COND 600 Conductivity/TDS/ºC/ºF 300.0 ppm to 4.000 ppt
4.000 to 40.00 ppt
40.00 to 200.0 ppt
CyberScan CON 400 Conductivity/TDS/ºC/ºF .. to 199.9 ppt *
CyberScan CON 110 Conductivity/TDS/ºC/ºF .. to 199.9 ppt *
CyberScan CON 11
Conductivity/TDS/ºC
.. to 199.9 ppt *
TDS 6+
TDS/ºC
.. to 199.9 ppt *
Bench Meters
pH/ORP/Ion/
Conductivity/TDS/
CyberScan PCD 6500 Salinity/Resistivity/
.. to 500 ppt
Dissolved Oxygen/BOD/
OUR/SOUR/ºC/ºF
pH/ORP/Ion/
CyberScan PC 6500 Conductivity/TDS/
.. to 500 ppt
Salinity/Resistivity/ºC/ºF
pH/ORP/Conductivity/
CyberScan PC 6000 TDS/Salinity/Resistivity/ .. to 500 ppt
ºC/ºF
pH/ORP/Ion/
0.050 ppm to 500 ppt
PC 2700
Conductivity/TDS/
(@ TDS factor 1.00)
Salinity/Resistivity/ºC/ºF
pH/ORP/Conductivity/ .. to 100.0 ppt @ 0.5 fact
PC 700
TDS/Resistivity/ºC/ºF
(200.0 @ 1 factor)
CyberScan CON 6000
Conductivity/TDS/
.. to 500 ppt
Salinity/Resistivity/ºC/ºF
CON 2700
Conductivity/TDS/
0.050 ppm to 500 ppt
Salinity/Resistivity/ºC/ºF (@ TDS factor 1.00)
.. to 100.0 ppt @ 0.5 fact
Conductivity/TDS/ºC/ºF
(200.0 @ 1 factor)
CON 700
* Maximum 199.9 ppt depending on factor setting ** Maximum 500 ppt depending on factor setting
page | 06
Pg 44
Pg 45
Pg 45
Pg 46
Internet/intranet,
RS232C, USB,
Pg 80
IrDA, SD card
Internet/intranet,
RS232C, USB,
Pg 80
IrDA, SD card
Salinity Meter Quick Guide
Models
Parameters
Salinity Range
Accuracy
Cal. Points GLP Memory
Temperature Housing
Page
Communication
Display
Rating
No.
±1 % full scale *
1 (manual
above
1.00 ppt)
Pocket Testers
PCSTestr 35
pH/Conductivity/TDS/
Salinity/ºC/ºF
SaltTestr 11
Salinity/ºC/ºF
0.0 to 99.9 ppm
100 to 999 ppm
1.00 to 10.00 ppt
0.0 to 1.00 %
.. to 10.00 ppt
EcoTestr Salt
Salinity
.. to 10.00 ppt
–
–
Yes
IP67
–
Pg 70
1 (manual) –
–
Yes
IP67
–
Pg 39
1
–
–
–
IP67
–
Pg 40
±1 % full scale
+ 1 LSD
5
Yes
500
Yes
IP67
LED RS232C, IrDA Pg 72
±1 % full scale
+ 1 LSD
5
Yes
500
Yes
IP67
LED RS232C, IrDA Pg 73
±1 % full scale
+ 1 LSD
5
Yes
500
Yes
IP67
LED RS232C, IrDA Pg 73
±1 % full scale
+ 1 LSD
5
Yes
500
Yes
IP67
LED RS232C, IrDA Pg 43
±1 % full scale
1 (manual) –
–
Yes
IP54
–
0.5 % full scale
+ LSD
5
Yes
1000 per
Yes
parameter
–
Internet/l intranet,
RS232C, USB,
Pg 79
IrDA, SD card
0.5 % full scale
+ LSD
5
Yes
1000 per
Yes
parameter
–
Internet/l intranet,
RS232C, USB,
Pg 80
IrDA, SD card
0.5 % full scale
+ LSD
5
Yes
1000 per
Yes
parameter
–
Internet/l intranet,
RS232C, USB,
Pg 80
IrDA, SD card
±1 % full scale
5
Yes
500
Yes
–
RS232
0.5 % full scale
+ LSD
5
Yes
1000 per
Yes
parameter
–
Internet/l intranet,
RS232C, USB,
Pg 50
IrDA, SD card
±1 % full scale
5
Yes
500
–
RS232
±1 % full scale
±1 % full scale
(±2 % above
5 ppt)
Handheld Meters
.. to 0.770 ppm
pH/ORP/Ion/
0.770 to 143.3 ppm
Conductivity/TDS/
CyberScan PCD 650
143.3 ppm to 2.138 ppt
Salinity/Resistivity/
2.183 to 23.64 ppt
Dissolved Oxygen/ºC/ºF
23.64 to 80.00 ppt
.. to 0.770 ppm
pH/ORP/Ion/
0.770 to 143.3 ppm
CyberScan PC 650
Conductivity/TDS/
143.3 ppm to 2.138 ppt
Salinity/Resistivity/ºC/ºF 2.183 to 23.64 ppt
23.64 to 80.00 ppt
.. to 0.770 ppm
Conductivity/TDS/
0.770 to 143.3 ppm
CyberScan CD 650
Salinity/Resistivity/
143.3 ppm to 2.138 ppt
Dissolved Oxygen/ºC/ºF 2.183 to 23.64 ppt
23.64 to 80.00 ppt
.. to 0.770 ppm
0.770 to 143.3 ppm
Conductivity/TDS/
CyberScan COND 610
143.3 ppm to 2.138 ppt
Salinity/Resistivity/ºC/ºF
2.183 to 23.64 ppt
23.64 to 80.00 ppt
1.0 to 50.00 ppt
Salt 6+
Salinity/ºC
0.1 to 5.00 %
Bench Meters
pH/ORP/Ion/
.. to 0.094 ppt
Conductivity/TDS/
0.094 to 1.000 ppt
CyberScan PCD 6500
Salinity/Resistivity/
1.0 to 11.50 ppt
Dissolved Oxygen/ºC/ºF 11.50 to 90.00 ppt
.. to 0.094 ppt
pH/ORP/Ion/
0.094 to 1.000 ppt
CyberScan PC 6500 Conductivity/TDS/
1.0 to 11.50 ppt
Salinity/Resistivity/ºC/ºF
11.50 to 90.00 ppt
.. to 0.094 ppt
pH/ORP/Conductivity/
0.094 to 1.000 ppt
CyberScan PC 6000 TDS/Salinity/Resistivity/
1.0 to 11.50 ppt
ºC/ºF
11.50 to 90.00 ppt
pH/ORP/Ion/
PC 2700
Conductivity/TDS/
0.0 to 80.0 ppt
Salinity/Resistivity/ºC/ºF
.. to 0.094 ppt
Conductivity/TDS/
0.094 to 1.000 ppt
CyberScan CON 6000
Salinity/Resistivity/ºC/ºF 1.0 to 11.50 ppt
11.50 to 90.00 ppt
Conductivity/TDS/
CON 2700
0 to 80.0 ppt
Salinity/Resistivity/ºC/ºF
Yes
Pg 47
Pg 81
Pg 51
* Applicable from 100 ppm to 10.00 ppt / 0.0 to 1.00 %
page | 07
Selection Guide
Meter Selection Guide
Salinity Meter Quick Guide
Selection Guide
Meter Selection Guide
DO Meter Quick Guide
Dissolved Oxygen Meter Quick Guide
Models
Parameters
DO Range
Accuracy
Cal. Points
GLP Memory
Barometric / Salinity Housing
Page
Communication
Compensation
Rating
No.
±2.0 %,
±0.2 mg/L
1 (mg/L)
Yes 500
Yes
IP67
LED RS232C, IrDA Pg 72
±2.0 %,
±0.2 mg/L
1 (mg/L)
Yes 500
Yes
IP67
LED RS232C, IrDA Pg 73
±2.0 %,
±0.2 mg/L
1 (mg/L)
Yes 500
Yes
IP67
LED RS232C, IrDA Pg 73
±2.0 %,
±0.2 mg/L
2 (0 %, 100 %)
Yes 500
1 (mg/L)
Yes
IP67
LED RS232C, IrDA Pg 58
±1.5 %
full scale
±1.5 %
full scale
±1.5 %
full scale
2 (0 %, 100 %)
Yes 50
1 (mg/L)
2 (0 %, 100 %)
–
100
1 (mg/L)
2 (0 %, 100 %)
–
–
1 (mg/L)
Yes
IP67
–
Pg 59
Yes
IP54
RS232C
Pg 60
Yes
IP54
–
Pg 61
–
Internet/intranet,
RS232C, USB, IrDA, Pg 79
SD card
2 (0 %, 100 %)
1000 per
2 (0 mg/L,
Yes
Yes
parameter
8.26 mg/L)
–
Internet/intranet,
RS232C, USB, IrDA, Pg 64
SD card
2
Yes 500
Yes
–
RS232C
Pg 65
2
–
Yes
–
–
Pg 66
Handheld Meters
CyberScan PCD 650
CyberScan PD 650
CyberScan CD 650
CyberScan DO 600
CyberScan DO 300
CyberScan DO 110
DO 6+
pH/ORP/Ion/
0 to 600 %,
Conductivity/TDS/
0.00 to 90.00 mg/L
Salinity/Resistivity/
or ppm
Dissolved Oxygen/ºC/ºF
0 to 600 %,
pH/ORP/Ion/Dissolved
0.00 to 90.00 mg/L
Oxygen/ºC/ºF
or ppm
Conductivity/TDS/
0 to 600 %,
Salinity/Resistivity/
0.00 to 90.00 mg/L
Dissolved Oxygen/ºC/ºF or ppm
0 to 600 %,
Dissolved Oxygen/ºC/ºF 0 to 90 mg/L
or ppm
0 to 199.9 %,
Dissolved Oxygen/ºC/ºF
0 to 19.99 mg/L
0 to 199.9 %,
Dissolved Oxygen/ºC/ºF
0 to 19.99 mg/L
0 to 199.9 %,
Dissolved Oxygen/ºC
0 to 19.99 mg/L
Bench Meters
pH/ORP/Ion/
Conductivity/TDS/
CyberScan PCD 6500 Salinity/Resistivity/
Dissolved Oxygen/
BOD/OUR/SOUR/ºC/ºF
CyberScan DO 6000
DO 2700
DO 700
page | 08
0 to 600 %,
0 to 60 mg/L
0 to 1272 mbar
0 to 600 %,
Dissolved Oxygen/BOD/
0 to 60 mg/L
OUR/SOUR/ºC/ºF
0 to 1272 mbar
Dissolved Oxygen/
0 to 600.0 %,
BOD/ºC/ºF
0.00 to 50.00 mg/L
0 to 199.9 %; 300 %,
Dissolved Oxygen/ºC/ºF
0 to 30 mg/L
0.1 %
2 (0 %, 100 %)
1000 per
0.1 +1 LSD 0.1 2 (0 mg/L,
Yes
Yes
parameter
mbar
8.26 mg/L)
0.1 %
0.1 +1 LSD 0.1
mbar
±0.5 %
full scale
±0.5 %
full scale
100
Multi-Parameter Meter Quick Guide
Models
Parameters
Range
Accuracy
pH
0.00 to 14.00 pH
±0.01 pH
.. to 200.0 µS ; 200 to 2000 µS ;
± 1 % full scale
2.00 to 20.00 mS
0.0 to 99.9 ppm ; 100 to 999 ppm ;
± 1 % full scale
1.00 to 10.00 ppt
Cal. Points GLP Memory
Temperature Housing
Page
Communication
Display
Rating
No.
Pocket Testers
Conductivity
PCSTestr 35
TDS
Temperature
pH
TDS
Temperature
pH
ORP
-2.000 to 20.000 pH
±2000.0 mV
Ion
0.001 to 19900
Temperature
pH
PTTestr 35
3 manual
1 (manual
0.0 to 99.9 ppm ; 100 to 999 ppm ;
± 1 % full scale * above
1.00 to 10.00 ppt ; 0.0 to 1.00 %
1.00 ppt)
0 to 50.0 ºC ; 32 to 122 ºF
0.5 ºC ; 0.9 ºF
–
0.0 to 14.0 pH
±0.01 pH
5 auto
2 auto
.. to 2000 µS ; 2.00 to 20.00 mS
± 1 % full scale
2 manual
0 to 50.0 ºC ; 32 to 122 ºF
0.5 ºC ; 0.9 ºF
–
0.0 to 14.0 pH
±0.01 pH
5 auto
0 to 999 ppm ; 1.00 to 10.00 ppt ± 1 % full scale 2 manual
0 to 50.0 ºC ; 32 to 122 ºF
0.5 ºC ; 0.9 ºF
–
Salinity
PCTestr 35
5 auto
3 auto
3 manual
Conductivity
–
–
Yes
IP67
–
Pg 70
–
–
Yes
IP67
–
Pg 70
–
–
Yes
IP67
–
Pg 70
Yes
500
Yes
IP67
LED RS232C, IrDA Pg 72
Yes
500
Yes
IP67
LED RS232C, IrDA Pg 73
Handheld Meters
CyberScan PCD 650
.. to 2.000 µS ;
2.000 to 300.0 µS ;
Conductivity
300.0 µS to 4.000 mS ;
4.000 to 40.00 mS ;
40.00 to 500.0 mS
.. to 2.000 ppm ; 2.000 to 300.0 ppm ;
300.0 ppm to 4.000 ppt ;
TDS
4.000 to 40.00 ppt ;
40.00 to 500.0 ppt
.. to 0.770 ppm ; 0.770 to 143.3 ppm ;
143.3 ppm to 2.138 ppt ;
Salinity
2.183 to 23.64 ppt ;
23.64 to 80.00 ppt
2.00 to 25.00 Ω ; 25.00 to 250.0 Ω ;
250.0 Ω to 3.333 kΩ ;
Resistivity
3.333 to 500.0 kΩ ;
500.0 kΩ to 20.00 MΩ
0.00 to 90.00 mg/L or ppm ;
Dissolved Oxygen
0 to 600.0 %
Temperature
-10.0 to 110.0 ºC ; 14.0 to 230.0 ºF
pH
-2.000 to 20.000 pH
ORP
±2000.0 mV
Ion
Conductivity
CyberScan PC 650
TDS
Salinity
Resistivity
Temperature
0.001 to 19900
.. to 2.000 µS ;
2.000 to 300.0 µS ;
300.0 µS to 4.000 mS ;
4.000 to 40.00 mS ;
40.00 to 500.0 mS
.. to 2.000 ppm ; 2.000 to 300.0 ppm ;
300.0 ppm to 4.000 ppt ;
4.000 to 40.00 ppt ;
40.00 to 500.0 ppt
.. to 0.770 ppm ; 0.770 to 143.3 ppm ;
143.3 ppm to 2.138 ppt ;
2.183 to 23.64 ppt ;
23.64 to 80.00 ppt
2.00 to 25.00 Ω ; 25.00 to 250.0 Ω ;
250.0 Ω to 3.333 kΩ ;
3.333 to 500.0 kΩ ;
500.0 kΩ to 20.00 MΩ
-10.0 to 110.0 ºC ; 14.0 to 230.0 ºF
* Applicable from 100 ppm to 10.00 ppt / 0.0 to 1.00 %
±0.002 pH
±0.2 mV
0.5 % full scale
(monovalent)
1 % full scale
(divalent)
6
–
8
±1 % full scale + 4 auto
1 LSD
5 manual
±1 % full scale +
5
1 LSD
±1 % full scale +
5
1 LSD
±1 % full scale
±0.2 mg/L
±2.0 %
±0.5 ºC ; ±0.9 ºF
±0.002 pH
±0.2 mV
0.5 % full scale
(monovalent)
1 % full scale
(divalent)
5
1
–
6
–
8
±1 % full scale + 4 auto
1 LSD
5 manual
±1 % full scale +
5
1 LSD
±1 % full scale +
5
1 LSD
±1 % full scale
5
±0.5 ºC ; ±0.9 ºF –
[ Continued on page 10 ]
page | 09
Selection Guide
Meter Selection Guide
Multi-Parameter
Meter Quick Guide
Selection Guide
Meter Selection Guide
Multi-Parameter
Meter Quick Guide
Multi-Parameter Meter Quick Guide
[ Continued from page 09 ]
Models
Parameters
Range
Accuracy
Cal. Points GLP Memory
pH
ORP
-2.000 to 20.000 pH
±2000.0 mV
6
–
Ion
0.001 to 19900
±0.002 pH
±0.2 mV
0.5 % full scale
(monovalent)
1 % full scale
(divalent)
±0.2 mg/L
±2.0 %
±0.5 ºC ;
±0.9 ºF
Temperature Housing
Page
Communication
Display
Rating
No.
Handheld Meters
CyberScan PD 650
0.00 to 90.00 mg/L or ppm
0 to 600.0 %
-10.0 to 110.0 ºC ;
Temperature
14.0 to 230.0 ºF
.. to 2.000 µS
2.000 to 300.0 µS
Conductivity
300.0 µS to 4.000 mS
4.000 to 40.00 mS
40.00 to 500.0 mS
.. to 2.000 ppm
2.000 to 300.0 ppm
TDS
300.0 ppm to 4.000 ppt
4.000 to 40.00 ppt
40.00 to 500.0 ppt
.. to 0.770 ppm
0.770 to 143.3 ppm
Salinity
143.3 ppm to 2.138 ppt
2.183 to 23.64 ppt
23.64 to 80.00 ppt
2.00 to 25.00 Ω
25.00 to 250.0 Ω
Resistivity
250.0 Ω to 3.333 kΩ
3.333 to 500.0 kΩ
500.0 kΩ to 20.00 MΩ
0.00 to 90.00 mg/L or ppm
Dissolved Oxygen
0 to 600.0 %
-10.0 to 110.0 ºC ;
Temperature
14.0 to 230.0 ºF
Dissolved Oxygen
CyberScan CD 650
8
Yes
500
Yes
IP67
LED RS232C, IrDA Pg 73
Yes
500
Yes
IP67
LED RS232C, IrDA Pg 73
Yes
1000 per
Yes
parameter
–
Internet, intranet,
RS232C, USB,
Pg 79
IrDA, SD card
1
–
±1 % full scale + 4 auto
1 LSD
5 manual
±1 % full scale +
5
1 LSD
±1 % full scale +
5
1 LSD
±1 % full scale
±0.2 mg/L
±2.0 %
±0.5 ºC ;
±0.9 ºF
5
1
–
Bench Meters
pH
ORP
Ion
Conductivity
TDS
CyberScan PCD 6500
Salinity
Resistivity
-2.000 to 20.000 pH
±2000.0 mV
1 x 10-7 to 9.99 x 1010 ppm
.. to 200 µS
200.0 µS to 2.000 mS
2.000 to 20.00 mS
20.00 to 500.0 mS
.. to 200 ppm
200.0 to 2000 ppm
2.000 to 20.00 ppt
20.00 to 500.0 ppt
.. to 0.094 ppt
0.094 to 1.000 ppt
1.0 to 11.50 ppt
11.50 to 90.00 ppt
0 to 20.00 kΩ
20.00 to 200.0 kΩ
200.0 kΩ to 2.000 MΩ
2.000 to 100.0 MΩ
±0.002 pH
±0.2 mV
±0.17 n %
5
–
5
0.5 % full scale
+ LSD
5
0.5 % full scale
+ LSD
5
0.5 % full scale
+ LSD
5
0.5 % full scale
+ LSD
5
0 to 600 %
Dissolved Oxygen 0 to 60 mg/L
0 to 1272 mbar
0.1 %
0.1 + 1 LSD
0.1 mbar
Temperature
±0.2 ºC
-5.0 to 105.0 ºC
2(0 %,
100 %)
2(0 mg/L,
8.26 mg/L)
–
[ Continued on page 11 ]
page | 10
Multi-Parameter Meter Quick Guide
[ Continued from page 10 ]
Models
Parameters
Range
Accuracy
Cal. Points GLP Memory
pH
ORP
Ion
±0.002 pH
±0.2 mV
±0.17 n %
5
1
5
0.5 % full scale
+ LSD
5
0.5 % full scale
+ LSD
5
0.5 % full scale
+ LSD
5
0.5 % full scale
+ LSD
5
±0.2 ºC
±0.002 pH
±0.2 mV
1
5
1
0.5 % full scale
+ LSD
5
0.5 % full scale
+ LSD
5
0.5 % full scale
+ LSD
5
0.5 % full scale
+ LSD
5
Temperature
pH
ORP
-2.000 to 20.000 pH
±2000.0 mV
1 x 10-7 to 9.99 x 1010 ppm
.. to 200 µS
200.0 µS to 2.000 mS
2.000 to 20.00 mS
20.00 to 500.0 mS
.. to 200 ppm
200.0 to 2000 ppm
2.000 to 20.00 ppt
20.00 to 500.0 ppt
.. to 0.094 ppt
0.094 to 1.000 ppt
1.0 to 11.50 ppt
11.50 to 90.00 ppt
0 to 20.00 kΩ
20.00 to 200.0 kΩ
200.0 kΩ to 2.000 MΩ
2.000 to 100.0 MΩ
-5.0 to 105.0 ºC
-2.000 to 20.000 pH
±2000.0 mV
.. to 200 µS
200.0 µS to 2.000 mS
2.000 to 20.00 mS
20.00 to 500.0 mS
.. to 200 ppm
200.0 to 2000 ppm
2.000 to 20.00 ppt
20.00 to 500.0 ppt
.. to 0.094 ppt
0.094 to 1.000 ppt
1.0 to 11.50 ppt
11.50 to 90.00 ppt
0 to 20.00 kΩ
20.00 to 200.0 kΩ
200.0 kΩ to 2.000 MΩ
2.000 to 100.0 MΩ
-5.0 to 105.0 ºC
-2.000 to 20.000 pH
±2000.0 mV
Ion
0.001 to 19999
Conductivity
TDS
Salinity
Resistivity
0.050 µS to 500.0 mS
0.050 mg/L to 500.0 g/L
0.0 to 80.0 ppt
2.000 Ω to 20.0 MΩ
0.0 to 100.0 ºC ;
32.0 to 212.0 ºF
Temperature Housing
Page
Communication
Display
Rating
No.
Bench Meters
Conductivity
CyberScan PC 6500
TDS
Salinity
Resistivity
Temperature
pH
ORP
Conductivity
TDS
CyberScan PC 6000
Salinity
Resistivity
PC 2700
Temperature
PC 700
pH
-2.00 to 16.00 pH
ORP
±2000 mV
Conductivity
0.0 µS to 200.0 mS
.. to 100.0 ppt @ 0.5 fact
(200.0 @ 1 factor)
0.0 to 100.0 ºC ;
32.0 to 212.0 ºF
TDS
Temperature
±0.2 ºC
±0.002 pH
0.1 mV
0.5 % full scale
(monovalent)
1 % full scale
(divalent)
±1 % full scale
±1 % full scale
±1 % full scale
±1 % full scale
±0.3 ºC ;
±0.5 ºF
±0.01 pH +
1 LSD
±0.2 mV
(±199.9 mV)
±2 mV (beyond)
±1 % full scale
1
6
1
±1 % full scale
5
±0.5 ºC ;
±0.9 ºF
1
Yes
1000 per
Yes
parameter
–
Internet, intranet,
RS232C, USB,
Pg 80
IrDA, SD card
Yes
1000 per
Yes
parameter
–
Internet, intranet,
RS232C, USB,
Pg 80
IrDA, SD card
Yes
500
Yes
–
RS232
Pg 81
–
100
Yes
–
–
Pg 82
2 to 8
5
5
5
5
1
5
1
5
page | 11
Selection Guide
Meter Selection Guide
Multi-Parameter
Meter Quick Guide
Selection Guide
Meter Selection Guide
Colorimeter Quick Guide
Colorimeter Quick Guide
Parameters
Range
Resolution
Accuracy
Chlorine,
Free and Total
Cyanuric Acid
pH
0 - 1.99 ppm
2.0 - 6.0 ppm
5 - 90 ppm
5.9 - 8.2 pH
0 - 3.79 ppm
3.8 - 11.4 ppm
0 - 1.39 ppm
1.4 - 4.1 ppm
0.01 ppm
0.1 ppm
1 ppm
0.1 pH
0.01 ppm
0.1 ppm
0.01 ppm
0.1 ppm
±0.02 ppm
±0.2 ppm
±4 ppm
±0.1 pH
±0.02 ppm
±0.2 ppm
±0.02 ppm
±0.2 ppm
Chlorine Dioxide
Ozone
Look for these features
in Eutech meters
page | 12
C401
C301
C201
C105
Page
No.
C103
3
3
3
–
–
3
3
–
3
–
–
–
–
–
–
–
–
–
–
3
–
–
–
3
–
Automatic Temperature Compensation
automatically corrects the measured value
based on the temperature of the solution with
the use of a built-in temperature sensor
CE-certified products
Manual Temperature Compensation is an
alternative method for temperature
compensation through the manual input
of sample temperature value
IP67-rated housing offers complete protection
against dust and allows immersion in water
between 15 cm to 1 m
Automatic Calibration frees users from
cumbersome fine adjustment or manual
selection of desired standards in Conductivity
and Dissolved Oxygen calibration routine
IP54-rated housing protects instrument from
dust and water spray from all directions
Auto-Buffer Recognition identifies and ensures
correct pH buffer values are being used
during calibration
Pocket testers, colorimeters and turbidity
meters are covered by Eutech warranty for
2 years
Good Laboratory Practices (GLP) refers to
regulations that are observed to ensure
high quality experimental standards and
reliable data
Handheld meters and bench meters are
covered by an extended warranty for 3 years
RS232C cable output for serial
communication between meters and PC
or other peripheral devices
All Eutech electrodes have 6 months warranty
Infrared communications technology for
wireless data transfer from meter to PC or other
peripheral devices
Automatic Pressure Compensation automatically
corrects dissolved oxygen measurements for
pressure changes from built-in barometric pressure
sensor for most accurate measurements
USB connectivity for output to PC or other
peripheral devices
Pg 89