A.O. Smith 100210123 ProLine® 40 gal Tall 38 MBH Residential Natural Gas Water Heater Specification

Add to My manuals
2 Pages

advertisement

A.O. Smith 100210123 ProLineĀ® 40 gal Tall 38 MBH Residential Natural Gas Water Heater Specification | Manualzz

Residential Gas

Water Heaters

DIRECT VENT

DIRECT VENT DESIGN

• One-pipe, dual-channel closed system draws all make-up air from outside the home, eliminating problems caused by insufficient indoor ventilation and is

FVIR compliant. Horizontal air intake and venting on all models up to 80 inches from outside wall with no electrical power needed.

INTELLIGENT CONTROL LOGIC

The internal microprocessor provides enhanced operating parameters and tighter differentials for precise sensing and faster heating response to optimize performance.

Uses a themopile to generate the power needed to operate the electronic gas control without requiring an external power source.

The electronic gas control incorporates an LED status indicator that monitors system operation and service diagnostics.

GREEN CHOICE® GAS BURNER

• Patented eco-friendly design reduces

NOx emissions up to 33% and complies with low emissions of less than 40 ng/J.

DYNACLEAN™ DIFFUSER DIP TUBE

• Helps reduce lime and sediment buildup and maximizes hot water output. Made from long-lasting PEX cross-linked polymer.

COREGARD™ ANODE ROD

• Our anode rods have a stainless steel core that extends the life of the anode rod allowing superior tank protection far longer than standard anode rods.

PUSH BUTTON PIEZO IGNITOR

• Makes lighting pilot fast and easy with one hand push button spark ignition.

HEAT TRAP NIPPLES

• Factory-installed for faster installation

ENHANCED-FLOW BRASS DRAIN

VALVE

Our residential water heaters have a solid brass, tamper resistant, enhancedflow, ball type, drain valve.

Uses a standard female hose fitting that allows for fast and easy draining during maintenance.

Designed for easy operation, this valve includes an integral screwdriver slot that features a ¼ turn (open/close) radius, which not only permits full straightthrough water flow but also a quick and positive shut off.

CSA CERTIFIED AND ASME RATED T&P

RELIEF VALVE

CODE COMPLIANCE

Meets UBC, CEC and HUD National

Codes.

Meets the thermal efficiency and standby loss requirements of the U.S.

Department of Energy and current edition of ASHRAE/IESNA 90.1

Complies with the Federal Energy

Conservation Standards effective April

16, 2015, in accordance with the Energy

Policy and Conservation Act (EPCA), as amended.

DESIGN-LISTED BY CSA

INTERNATIONAL

• Certified at 300 PSI test pressure and 150 PSI working pressure. Listed according to ANSI Z21.10.1-CSA 4.1 standards governing storage tank-type gas water heaters.

6-YEAR LIMITED TANK AND PARTS

WARRANTY

• For complete information, consult written warranty or go to hotwater.com.

©2015 A. O. Smith Corporation. All rights reserved.

www.hotwater.com | 800-527-1953 Toll-Free USA | A. O. Smith Corporation | 500 Tennessee Waltz Parkway | Ashland City, TN 37015

Page 1 of 2

AOSSRG45702

Residential Gas

Water Heaters

Model

Number

GDV-40

GDV-50

GDVT-50

Gallon

Capacity

40

50

50

First Hour

Rating

Gallon

72

91

92

Energy

Factor

0.63

0.62

0.61

Input BTU

Per Hour

38,000

40,000

47,000

Recovery

9OºF Rise

Gallon Per

Hour

41

43

51

Dual-channel system has 3” vent pipe inside 6” air intake pipe, for the 40 and 50-gallon models.

All models have 2” foam cavity.

Water connection is 3/4” male on 8” center.

*Allow 29” for front to back dimension for gas control and air intake pipe at the rear of the heater.

No option available for top T&P.

A B C

Dimensions in Inches

D E F *G H

Vent

Outlet

Approx.

Shipping

Weight (lbs)

64 49-3/4 22 13-1/4 15-1/4 42-1/2 29 15-1/4 Co-Axial

73

74

59

60

22

22

13-1/4 15-1/4 51-3/4

13-1/4 15-1/4 52-3/4

29

29

15-1/4

15-1/4

Co-Axial

Co-Axial

178

200

215

All models are available in propane (LP) gas (series 301).

All models are certified from sea level to 7,700 ft. elevation.

All models available with side connections. Add “L” to the model number, example GDV-40L

Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement.

IMPORTANT! VENT INSTALLATION AND

TERMINATION REQUIREMENTS

Maximum horizontal vent distance is 80” to the outside of exterior wall.

Maximum vertical vent distance is 72” above heater before 90 degree turn through exterior wall.

Minimum horizontal vent distance is 17” to outside of exterior wall.

Vent pipes may be trimmed (cut) for short vent installations.

The recommended installation height for the vent termination is dimension “A” in the above table. The minimum allowable height (center line of termination opening) is 60 ¾” for the 40-gallon model, 69 ½” for the 50-gallon 40,000 BTU input model, 70 ½” for the

50-gallon model, 47,000 BTU input model.

VENT RESTRICTOR PLATE:

• The vent restrictor plate is required for short horizontal vent runs less than 30” horizontal and for vent runs when the termination’s height is greater than 48” above the heater. The only time the restrictor is not required is for horizontal runs greater than 30” in length with the termination less (lower) than 48” above the heater. See installation instructions for complete details.

OFFSET VENT ARRANGEMENT:

The vent run may have one (1) 90 degree horizontal turn prior to terminating through the exterior wall. See installation instructions for complete details.

Vent termination clearance hole through the exterior wall should be approximately 7” diameter.

Snow accumulation and drifting should be considered when locating the termination.

An optional wire grill vent cap protector is available through the parts department (part number

9006627005).

See the installation manual for complete installation and venting requirements.

A

3/4” MALE NPT

OUTLET & INLET

21º

MINIMUM VENT

17”

MAXIMUM VENT

80”

6” DIA. ON 40 & 50 GAL. MODELS

SIDE TAP AND T&P

FRONT

E

EXTERIOR

WALL

For technical information call 800-527-1953. A. O. Smith Corporation reserves the right to make product changes or improvements without prior notice.