Residential Gas
Water Heaters
DIRECT VENT
DIRECT VENT DESIGN
• One-pipe, dual-channel closed system draws all make-up air from outside the home, eliminating problems caused by insufficient indoor ventilation and is
FVIR compliant. Horizontal air intake and venting on all models up to 80 inches from outside wall with no electrical power needed.
INTELLIGENT CONTROL LOGIC
•
•
•
The internal microprocessor provides enhanced operating parameters and tighter differentials for precise sensing and faster heating response to optimize performance.
Uses a themopile to generate the power needed to operate the electronic gas control without requiring an external power source.
The electronic gas control incorporates an LED status indicator that monitors system operation and service diagnostics.
GREEN CHOICE® GAS BURNER
• Patented eco-friendly design reduces
NOx emissions up to 33% and complies with low emissions of less than 40 ng/J.
DYNACLEAN™ DIFFUSER DIP TUBE
• Helps reduce lime and sediment buildup and maximizes hot water output. Made from long-lasting PEX cross-linked polymer.
COREGARD™ ANODE ROD
• Our anode rods have a stainless steel core that extends the life of the anode rod allowing superior tank protection far longer than standard anode rods.
PUSH BUTTON PIEZO IGNITOR
• Makes lighting pilot fast and easy with one hand push button spark ignition.
HEAT TRAP NIPPLES
• Factory-installed for faster installation
ENHANCED-FLOW BRASS DRAIN
VALVE
•
•
•
Our residential water heaters have a solid brass, tamper resistant, enhancedflow, ball type, drain valve.
Uses a standard female hose fitting that allows for fast and easy draining during maintenance.
Designed for easy operation, this valve includes an integral screwdriver slot that features a ¼ turn (open/close) radius, which not only permits full straightthrough water flow but also a quick and positive shut off.
CSA CERTIFIED AND ASME RATED T&P
RELIEF VALVE
CODE COMPLIANCE
•
•
•
Meets UBC, CEC and HUD National
Codes.
Meets the thermal efficiency and standby loss requirements of the U.S.
Department of Energy and current edition of ASHRAE/IESNA 90.1
Complies with the Federal Energy
Conservation Standards effective April
16, 2015, in accordance with the Energy
Policy and Conservation Act (EPCA), as amended.
DESIGN-LISTED BY CSA
INTERNATIONAL
• Certified at 300 PSI test pressure and 150 PSI working pressure. Listed according to ANSI Z21.10.1-CSA 4.1 standards governing storage tank-type gas water heaters.
6-YEAR LIMITED TANK AND PARTS
WARRANTY
• For complete information, consult written warranty or go to hotwater.com.
©2015 A. O. Smith Corporation. All rights reserved.
www.hotwater.com | 800-527-1953 Toll-Free USA | A. O. Smith Corporation | 500 Tennessee Waltz Parkway | Ashland City, TN 37015
Page 1 of 2
AOSSRG45702
Residential Gas
Water Heaters
Model
Number
GDV-40
GDV-50
GDVT-50
Gallon
Capacity
40
50
50
First Hour
Rating
Gallon
72
91
92
Energy
Factor
0.63
0.62
0.61
Input BTU
Per Hour
38,000
40,000
47,000
Recovery
9OºF Rise
Gallon Per
Hour
41
43
51
Dual-channel system has 3” vent pipe inside 6” air intake pipe, for the 40 and 50-gallon models.
All models have 2” foam cavity.
Water connection is 3/4” male on 8” center.
*Allow 29” for front to back dimension for gas control and air intake pipe at the rear of the heater.
No option available for top T&P.
A B C
Dimensions in Inches
D E F *G H
Vent
Outlet
Approx.
Shipping
Weight (lbs)
64 49-3/4 22 13-1/4 15-1/4 42-1/2 29 15-1/4 Co-Axial
73
74
59
60
22
22
13-1/4 15-1/4 51-3/4
13-1/4 15-1/4 52-3/4
29
29
15-1/4
15-1/4
Co-Axial
Co-Axial
178
200
215
All models are available in propane (LP) gas (series 301).
All models are certified from sea level to 7,700 ft. elevation.
All models available with side connections. Add “L” to the model number, example GDV-40L
Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement.
IMPORTANT! VENT INSTALLATION AND
TERMINATION REQUIREMENTS
•
•
•
•
•
Maximum horizontal vent distance is 80” to the outside of exterior wall.
Maximum vertical vent distance is 72” above heater before 90 degree turn through exterior wall.
Minimum horizontal vent distance is 17” to outside of exterior wall.
Vent pipes may be trimmed (cut) for short vent installations.
The recommended installation height for the vent termination is dimension “A” in the above table. The minimum allowable height (center line of termination opening) is 60 ¾” for the 40-gallon model, 69 ½” for the 50-gallon 40,000 BTU input model, 70 ½” for the
50-gallon model, 47,000 BTU input model.
VENT RESTRICTOR PLATE:
• The vent restrictor plate is required for short horizontal vent runs less than 30” horizontal and for vent runs when the termination’s height is greater than 48” above the heater. The only time the restrictor is not required is for horizontal runs greater than 30” in length with the termination less (lower) than 48” above the heater. See installation instructions for complete details.
OFFSET VENT ARRANGEMENT:
•
•
•
•
•
The vent run may have one (1) 90 degree horizontal turn prior to terminating through the exterior wall. See installation instructions for complete details.
Vent termination clearance hole through the exterior wall should be approximately 7” diameter.
Snow accumulation and drifting should be considered when locating the termination.
An optional wire grill vent cap protector is available through the parts department (part number
9006627005).
See the installation manual for complete installation and venting requirements.
A
3/4” MALE NPT
OUTLET & INLET
21º
MINIMUM VENT
17”
MAXIMUM VENT
80”
6” DIA. ON 40 & 50 GAL. MODELS
SIDE TAP AND T&P
FRONT
E
EXTERIOR
WALL
For technical information call 800-527-1953. A. O. Smith Corporation reserves the right to make product changes or improvements without prior notice.