HIGHLY-EFFICIENT 4-WAY MULTIPOISE
FIXED-CAPACITY DIRECT-VENT
DELUXE CONDENSING GAS FURNACE
352MAV
Sizes 060 thru 120
Series A
is made easier with our media filter cabinet—a standard accessory
on all furnaces. When installed as a part of your system, this cabinet
allows for an easy and convenient addition of a Bryant highefficiency air filter.
Two Stage Gas Valve —The 352MAV has a 2-stage gas valve to
vary the amount of gas being used from low-heat to high-heat
stage. The low-stage operation allows longer running periods,
which helps maintain your most comfortable temperature, prevents
drafts, reduces noise, and enhances the air quality of your home.
During the extreme cold, the high-heat levels will run to ensure that
you are still comfortable.
Permanent Split Capacitor (PSC) Blower Motor — The 352MAV
has a PSC blower motor that has several preselected fixed speeds
which can be customized to duct work installation requirements.
The motor has a wide application of use, a basic control scheme,
and is extremely reliable.
Two-Speed Inducer Motor — This motor works with the inducer
fan to optimize combustion efficiency and exhaust the flue gases
out of the house. The motor has two speeds and an incorporated
fan to keep the motor cool while reducing sound.
Adaptive Logic Control Board — This self-adjusting control
board contains a computer chip which automatically calculates the
precise amount of time your furnace should run and at what speed
it should run to obtain the best comfort and energy efficiency. This
control board also includes an extensive troubleshooting and
component test sequence that can monitor your heating system to
ensure that it is operating properly.
Utilizing the extensive resources available to Bryant, a new standard of excellence has been achieved with the model 352MAV
Plus 90tTM 4-Way Multipoise Furnace.
The model 352MAV is a unique 4-way multipoise condensing
furnace with features like no other product in its class. The
352MAV builds on the many Bryant successes in the furnace industry and establishes a new standard for all high-efficiency gas
furnaces.
FEATURES
4-Way Multipoise Design — Allows the model 352MAV to be
installed in an upflow, downflow, or horizontal orientation. Factory
configured for upflow applications with only simple drain connection
changes required for conversion to downflow or horizontal.
Primary Heat Exchanger & Secondary Heat Exchanger — The
primary heat exchanger is corrosion resistant and maintains a
proven track record for long-term reliability and high-efficiency
performance. The secondary heat exchanger is built with a
patented lamination process that bonds a corrosion-proof lining of
polypropylene to a heavy, galvanized steel shell. The unique
secondary clamshell design allows wider spacing between cells for
reduced air resistance through the furnace, reduced load on the
blower motor, and reduced need for cleaning.
Hot Surface Ignitor — This electronic ignition prevents wasted gas
associated with pilot lights.
Soft Motor Mounts — These motor mounts help to absorb shock,
decrease the vibration of the motor, and minimize noise.
Full Cabinet Insulation — This insulation completely surrounds
the internal furnace casing allowing for reduced and dampened
sounds and maintained efficiencies.
Media Filter Cabinet — Enhanced indoor air quality in your home
Form No. PDS 352M.60.1
—2—
11⁄4"
1"
14 1⁄2"
TYP
24 1⁄2"
2-IN. VENT CONN
⁄2-IN. DIA
GAS CONN
1
2-IN. COMBUSTIONAIR CONN
22 ⁄16"
5
26 15⁄16" TYP
23 1⁄4" TYP
SIDE INLET
SIDE INLET
⁄2-IN. DIA THERMOSTAT
ENTRY
22 11⁄16"
1
26 15⁄16"
26 1⁄4"
/16"
11
E
INLET
OUTLET
D
/16"
11
A
17-1/2
17-1/2
17-1/2
21
21
24-1/2
UNIT SIZE
036060
036080
048080
048100
060100
060120
22-7/8
19-3/8
19-3/8
15-7/8
15-7/8
15-7/8
D
DIMENSIONS (In.)
E
23
19-1/2
19-1/2
16
16
16
18 1⁄4"
9
⁄16"
TYP
DIMPLE LOCATORS
FOR HORIZONTAL
HANGING
CONDENSATE
DRAIN LOCATION
(UPFLOW)
30 ⁄2"
1
CONDENSATE DRAIN
TRAP LOCATION
(DOWNFLOW &
HORIZONTAL RIGHT)
OR ALTERNATE
1
⁄2-IN. DIA GAS CONN
13/16"
252
196
193
175
172
163
SHIP. WEIGHT (Lb)
NOTES: Minimum return-air opening at furnace, based on metal
duct. If flex duct is used, see flex duct manufacturer's
recommendation for equivalent diameters:
1. For 800 CFM 16-in. round or 14-1/2 X 12-in. rectangle.
2. For 1200 CFM 20-in. round or 14-1/2 X 19-1/2 in. rectangle.
3. For 1600 CFM 22-in. round or 14-1/2 X 23-1/4 in. rectangle.
4. For airflow requirements above 1800 CFM, see Air Delivery
Table in Product Data literature for specific use of single side
inlets. The use of both side inlets, a combination of 1 side and
the bottom, or the bottom only will ensure adequate return-air
openings for airflow requirements above 1800 CFM.
CONDENSATE
DRAIN LOCATION
(UPFLOW)
9 7⁄16"
TYP
33 1⁄4"
TYP
32 5⁄8"
TYP
30 13⁄16"
29 11⁄16"
TYP
27 5⁄8"
27 9⁄16"
TYP
24 1⁄2"
17 5⁄16"
CONDENSATE
DRAIN TRAP
LOCATION
(ALTERNATE
UPFLOW)
⁄8-IN. DIA
ACCESSORY
POWER ENTRY
7
⁄8-IN. DIA
POWER CONN
7
CONDENSATE DRAIN
TRAP LOCATION
(DOWNFLOW &
HORIZONTAL LEFT)
13/16"
A
AIRFLOW
24 ⁄16"
BOTTOM INLET
3
22 1⁄4" TYP
SIDE INLET
22 11⁄16"
2-IN. VENT CONN
⁄2-IN. DIA
THERMOSTAT ENTRY
1
⁄8-IN. DIA
POWER CONN
7
⁄2-IN. DIA
GAS CONN
1
2-IN. COMBUSTIONAIR CONN
OUTLET
19"
22 5⁄16"
26 1⁄4"
28 1⁄2"
26 15⁄16"
11⁄16"
7⁄16"
1"
A98569
39 7⁄8"
⁄16"
5
⁄8"
5
13⁄16"
INSTALLATION
This forced air furnace is equipped for use with natural gas at altitudes 0 - 10,000 ft (0 - 3,050m).
An accessory kit, supplied by the manufacturer, shall be used to convert to propane gas use or may be required for some natural gas applications.
This furnace is for indoor installation in a building constructed on site. This furnace may be installed in a manufactured (mobile) home when stated on rating plate and using factory
authorized kit.
This furnace may be installed on combustible flooring in alcove or closet at minimum clearance from combustible material.
This appliance requires a special venting system. Refer to the installation instructions for parts list and method of installation. This furnace is for use with schedule-40 PVC, PVCDWV, CPVC, or ABS-DWV pipe, and must not be vented in common with other gas-fired appliances. Construction through which vent/air intake pipes may be installed is maximum 24
inches (600 mm), minimum 3/4 inches (19 mm) thickness (including roofing materials).
LEVEL (0")
TO
1/2" MAX
Furnace must be installed level, or pitched forward within 1/2 inch of level for proper
drainage. Failure will result in equipment or property damage. See Installation
LEVEL (0")
TO
1/2" MAX
Manual for IMPORTANT unit support details on horizontal applications.
UPFLOW OR
DOWNFLOW
FRONT
FRONT
HORIZONTAL
MINIMUM INCHES CLEARANCE TO COMBUSTIBLE CONSTRUCTION
This furnace is approved for UPFLOW, DOWNFLOW and
HORIZONTAL installations.
ALL POSITIONS:
Clearance arrows do
not change with
furnace orientation.
Minimum front clearance for service 30 inches (762mm).
TOP/PLENUM
*
1"
DOWNFLOW POSITIONS:
†† For installation on combustible floors only when installed on special base No. KGASB0201ALL, Coil
††
0"B A
Assembly, Part No. CD5 or CK5, or Coil Casing, Part No. KCAKC.
HORIZONTAL POSITIONS:
CK
Line contact is permissible only between lines formed by intersections of top and two sides of furnace
jacket, and building joists, studs, or framing.
Clearance shown is for air inlet and air outlet ends.
ø 120 size furnaces require 1 inch bottom clearance to combustible materials.
R
FU
§
NA
S
CE
FR
ON
SI
§
RO
0"
RV
IC
E
NT
3"
*30
MIN
BOTTOM
326476-201 REV. B (lit-top)
F
0" §
T
SE
DE
E
ID
Clearance in inches
0"
§ø
Vent clearance to
combustibles 0".
A01049
Non-Programmable Thermostat Selection
TSTATBBNAC01-B
For use with 1-spd. Air Conditioner - deg. F/C, Auto Changeover
TSTATBBNHP01-B*
For use with 1-spd. Air Conditioner - deg. F/C, Auto Changeover
TSTATBBN2S01-B*
For use with 2-spd. Air Conditioner - deg. F/C, Auto Changeover
TSTATBBBAC01-B
For use with 1-spd. Air Conditioner - deg. F/C
TSTATBBPRH01-B**
For multi-use / stage configurations - deg. F/C, Auto Changeover/Temperature and Humidity Control
* Model HP and 2S thermostat must be field converted to air conditioner operation.
**Thermidistat control is versatile and can be configured for multiple use and staging, it must be configured for each specific application.
Programmable Thermostat Selection
TSTATBBPAC01-B
For use with 1-spd. Air Conditioner - deg. F/C, Auto Changeover, 7-Day Programmable
TSTATBBPHP01-B*
For use with 1-spd. Air Conditioner - deg. F/C, Auto Changeover, 7-Day Programmable
TSTATBBP2S01-B*
For use with 2-spd. Air Conditioner - deg. F/C, Auto Changeover, 7-Day Programmable
TSTATBBSAC01
For use with 1-spd. Air Conditioner - deg. F/C, 5-2 Day Programmable
TSTATBBPDF01-B**
For use with multi-stage applications - deg. F/C, Auto Changeover, 7-Day Programmable
TSTATBBPRH01-B***
For multi-use / stage configurations - deg. F/C, Auto Changeover, 7-Day Programmable/Temperature and Humidity Control
* Model HP and 2S thermostat must be field converted to air conditioner operation.
**Dual Fuel thermostat is used with furnace and heat pump application
***Thermidistat control can be configured for multiple use and staging, it must be configured for each specific application.
Zoning Control Selection
ZONEKIT2ZBDP
Zone Perfect Two-Zone kit
ZONEBB2KIT01-B
Zone Perfect Plus 2-Zone kit/Temperature and Humidity Control
ZONEBB4KIT01-B
Zone Perfect Plus 4-Zone kit/Temperature and Humidity Control
ZONEBB8KIT01-B
Zone Perfect Plus 8-Zone kit/Temperature and Humidity Control
—3—
SPECIFICATIONS
UNIT SIZE
RATINGS AND PERFORMANCE
Input Btuh*
Output Capacity† Nonweatherized ICS
(Shaded capacities are
specified on rating plate)
Low
High
AFUE%†
Nonweatherized ICS
Certified Temperature Rise Range °F
Certified External Static Pressure (ESP)
(In. wc)
Airflow CFM‡
Low
High
Upflow
Downflow
Horizontal
Upflow
Downflow
Horizontal
Upflow
Downflow
Horizontal
Low
High
Heating
Cooling
Heating Low
Heating High
Cooling
036060
036080
048080
048100
060100
060120
39,000
60,000
37,000
37,000
37,000
56,000
57,000
56,000
93.0
91.5
92.3
20—50
30—60
0.12
0.5
680
1010
1275
52,000
80,000
49,000
49,000
49,000
75,000
75,000
75,000
93.0
91.5
92.3
30—60
40—70
0.15
0.5
790
1130
1380
52,000
80,000
49,000
49,000
49,000
75,000
75,000
75,000
93.0
91.5
92.3
30—60
30—60
0.15
0.5
775
1190
1565
65,000
100,000
61,000
61,000
61,000
94,000
94,000
94,000
93.0
91.5
92.3
25—55
45—75
0.2
0.5
1175
1315
1570
65,000
100,000
61,000
61,000
61,000
94,000
94,000
94,000
93.0
91.5
92.3
30—60
30—60
0.2
0.5
1205
1795
2035
78,000
120,000
74,000
74,000
73,000
113,000
113,000
112,000
93.0
91.5
92.3
30—60
40—70
0.2
0.5
1215
1770
2075
13.3
17.5
12
33
20
12.9
16.8
12
34
20
ELECTRICAL
Unit Volts—Hertz—Phase
Operating Voltage Range Min-Max**
Maximum Unit Amps
Unit Ampacity††
Minimum Wire Size
Maximum Wire Length (Ft)‡‡
Maximum Fuse Size or Ckt Bkr Amps †††
Transformer (24v)
External Control Power Available
8.4
11.3
14
33
15
8.1
10.8
14
34
15
Heating
Cooling
Air Conditioning Blower Relay
115—60—1
104—127
11.6
11.6
15.3
15.4
12
12
37
37
20
20
40va
19
35
Standard
CONTROLS
Limit Control
Heating Blower Control (Off Delay)
Burners (Monoport)
Gas Connection Size
SPST
Selectable 90, 135, 180, or 225 Seconds
4
4
5
5
1/2-in. NPT
3
6
GAS CONTROLS
2-Stage Redundant Gas Valve
Manufacturer
White-Rodgers
Min Inlet Pressure (In. wc)
4.5 (Natural Gas)
Max Inlet Pressure (In. wc)
13.6 (Natural Gas)
Hot Surface
Ignition Device
BLOWER DATA
Direct-Drive Motor HP (Permanent Split Capacitor)
Motor Full Load Amps
RPM (Nominal)—Speeds
Blower Wheel Diameter x Width (In.)
Filter Size (In.)—Permanent Washable
1/3
5.1
1075—5
10 7
1/3
5.1
1075—5
10 7
(1) 16 25 1
FACTORY-AUTHORIZED AND LISTED DEALER-INSTALLED OPTIONS
Gas Conversion Kit—Natural-to-Propane
Gas Conversion Kit—Propane-to-Natural
1/2
7.4
1075—5
11 8
1/2
7.9
1075—4
11 8
3/4
11
1075—5
11 10
(1) 20 25 1
KGANP2701LPS
KGAPN2201ALL
Twinning Kit—Upflow ONLY
Downflow Base***
Vent Termination Kit (Bracket Only for 2 Pipes)
Concentric Vent Termination Kit (Single Exit)
N/A
KGATW0501HSI
KGASB0201ALL
2-in.—KGAVT0101BRA aaaa3-in.—KGAVT0201BRA
2-in.—KGAVT0501CVT aaaa3-in.—KGAVT0601CVT
Condensate Freeze Protection Kit
KGAHT0101CFP
Electronic/Mechanical Air Cleaner
Model MACA, AIRA, or 902B
Humidifier
Heat/Energy Recovery Ventilator
Vent/Exhaust Pipe External Trap Kit
Model HUM
Model HRV, ERV
KGAET0106ETK
See notes on page 5.
—4—
3/4
11
1075—5
11 10
(1) 24 25 1
COMBUSTION-AIR AND VENT PIPING
MAXIMUM ALLOWABLE PIPE LENGTH (FT)
ALTITUDE
ABOVE SEA
LEVEL (FT)
UNIT SIZE
TERMINATION TYPE
036060
2 Pipe or 2-In. Concentric
036080
048080
2 Pipe or 2-In. Concentric
0 to 2000
2001 to 3000
3001 to 4000
4001 to 5000‡
048100
060100
2 Pipe or 3-In. Concentric
060120
2 Pipe or 3-In. Concentric
036060
2 Pipe or 2-In. Concentric
036080
048080
2 Pipe or 2-In. Concentric
048100
060100
2 Pipe or 3-In. Concentric
060120
2 Pipe or 3-In. Concentric
036060
2 Pipe or 2-In. Concentric
036080
048080
2 Pipe or 2-In. Concentric
048100
060100
2 Pipe or 3-In. Concentric
060120
2 Pipe or 3-In. Concentric
036060
2 Pipe or 2-In. Concentric
036080
048080
2 Pipe or 2-in Concentric
048100
060100
2 Pipe or 3-In. Concentric
060120
2 Pipe or 3-In. Concentric
PIPE DIA
(IN.)*
1-1/2
2
1-1/2
2
2-1/2
2
2-1/2
3
2-1/2 one disk
3†
3† no disk
4† no disk
1-1/2
2
2
2-1/2
2-1/2
3
3
3† no disk
4† no disk
1-1/2
2
2
2-1/2
2-1/2
3
3† no disk
4† no disk
1-1/2
2
2
2-1/2
2-1/2
3
3† no disk
4† no disk
1
20
70
10
55
70
5
40
70
10
45
70
70
17
70
49
70
35
70
14
70
70
16
68
46
70
33
70
65
70
15
64
44
70
31
70
53
70
2
15
70
NA
50
70
NA
30
70
NA
40
70
70
12
67
44
70
26
70
9
70
70
11
63
41
70
24
70
58
70
10
59
39
70
22
70
46
70
NUMBER OF 90° ELBOWS
3
4
10
5
70
70
NA
NA
35
30
70
70
NA
NA
20
20
70
70
NA
NA
35
30
70
70
70
70
7
NA
66
61
30
25
70
70
16
16
70
70
NA
NA
63
56
70
70
6
NA
62
57
28
23
70
70
15
14
70
66
51
44
70
70
5
NA
58
53
26
21
70
70
13
12
67
62
40
33
70
70
5
NA
70
NA
30
70
NA
10
70
NA
25
70
70
NA
61
25
70
6
66
NA
50
70
NA
57
22
70
5
61
38
70
NA
52
20
70
NA
57
26
70
6
NA
70
NA
20
70
NA
NA
70
NA
20
70
70
NA
61
15
70
NA
61
NA
43
70
NA
56
13
70
NA
56
31
70
NA
52
11
70
NA
52
20
70
See notes on page 7.
* Gas input ratings are certified for elevations to 2000 ft. For elevations above 2000 ft, reduce ratings 2% for each 1000 ft above sea level. In Canada, derate
the unit 5% from 2000 to 4500 ft above sea level.
† Capacity and AFUE in accordance with U.S. Government DOE test procedures effective November 10, 1997.
‡ • Airflow shown is with factory-supplied 1-in. washable filter(s).
• For air delivery above 1800 CFM, see Air Delivery table for other options.
• An airflow reduction of up to 7% may occur when using the factory-specified 4 5/16-inch wide, high efficiency media filter.
• For best furnace efficiency when using the 4 5/16-inch wide media filter, adjust the blower speed tap to near the mid-point of the rise range.
** Permissible voltage limits for proper furnace operation.
†† Unit ampacity = 125% of largest component’s full load amps plus 100% of all other potential operating components (EAC, humidifier, etc.).
‡‡ Length shown is measured 1 way along wire path between unit and service panel for maximum 2% voltage drop.
*** Required for installation on combustible floors when no coil box is used, or when any coil box other than a Bryant CD5 or CK5 cased coil is used.
N/A—Not applicable
ICS—Isolated Combustion System
—5—
MAXIMUM ALLOWABLE PIPE LENGTH (FT) Continued
ALTITUDE
ABOVE SEA
LEVEL (FT)
5001 to 6000‡
6001 to 7000‡
7001 to 8000‡
8001 to 9000‡
9001 to
10,000‡
UNIT SIZE
TERMINATION TYPE
036060
2 Pipe or 2-In. Concentric
036080
048080
2 Pipe or 2-In. Concentric
048100
060100
2 Pipe or 3-in Concentric
060120
2 Pipe or 3-In. Concentric
036060
2 Pipe or 2-In. Concentric
036080
048080
2 Pipe or 2-In. Concentric
048100
060100
2 Pipe or 3-In. Concentric
060120
2 Pipe or 3-In. Concentric
036060
2 Pipe or 2-In. Concentric
036080
048080
2 Pipe or 2-In. Concentric
048100
060100
2 Pipe or 3-In. Concentric
060120
2 Pipe or 3-In. Concentric
036060
2 Pipe or 2-In. Concentric
036080
048080
2 Pipe or 2-In. Concentric
048100
060100
2 Pipe or 3-In. Concentric
060120
2 Pipe or 3-In. Concentric
036060
036080
048080
2 Pipe or 2-In. Concentric
048100
060100
060120
2 Pipe or 2-In. Concentric
2 Pipe or 3-In. Concentric
2 Pipe or 3-In. Concentric
PIPE DIA
(IN.)*
1-1/2
2
2
2-1/2
2-1/2
3
3† no disk
4† no disk
1-1/2
2
2
2-1/2
2-1/2
3
3† no disk
4† no disk
1-1/2
2
2
2-1/2
2-1/2
3
3† no disk
4† no disk
1-1/2
2
2
2-1/2
2-1/2
3
3† no disk
4† no disk
2
2
2-1/2
2-1/2
3
4† no disk
1
14
60
41
70
29
70
42
70
13
57
38
70
27
68
31
70
12
53
36
66
25
63
20
61
11
49
33
62
23
59
10
35
45
30
57
21
54
10
2
9
55
36
70
21
67
35
70
8
52
33
70
19
63
24
70
7
48
31
65
17
58
13
56
6
44
28
60
15
54
NA
30
40
25
55
13
49
5
NUMBER OF 90° ELBOWS
3
4
NA
NA
54
49
23
18
70
70
12
11
62
57
29
22
70
70
NA
NA
50
45
21
16
68
67
10
9
58
53
18
11
70
70
NA
NA
46
41
19
14
63
62
8
7
53
48
7
NA
51
46
NA
NA
42
37
17
12
58
56
7
5
49
44
NA
NA
25
20
38
33
14
9
53
51
5
NA
44
39
NA
NA
5
NA
48
17
70
NA
52
15
70
NA
44
15
66
NA
48
NA
67
NA
40
12
60
NA
43
NA
41
NA
35
10
55
NA
39
NA
15
31
7
49
NA
34
NA
6
NA
47
8
70
NA
47
9
70
NA
43
6
64
NA
43
NA
62
NA
38
NA
59
NA
38
NA
36
NA
34
NA
53
NA
34
NA
10
29
NA
47
NA
29
NA
* Disk usage—Unless otherwise specified, use perforated disk assembly (factory-supplied in loose parts bag). If one disk is stated, separate 2 halves of
perforated disk assembly and use shouldered disk half. When using shouldered disk half, install screen side toward inlet box.
† Long radius elbow.
‡ Vent sizing for Canadian installations over 4500 ft (1370m) above sea level are subject to acceptance by the local authorities having jurisdiction.
NA—Not Allowed; pressure switch will not make.
NOTES:
1. Do not use pipe size greater than those specified in table or incomplete combustion, flame disturbance, or flame sense lockout may occur.
2. Size both the combustion-air and vent pipe independently determine the smallest diameter allowed by the chart for each pipe, then use the larger of these
two diameters for both pipes.
3. Assume two 45° elbows equal one 90° elbow. Long radius elbows are desirable and may be required in some cases.
4. Elbows and pipe sections within the furnace casing and at the vent termination should not be included in vent length or elbow count.
5. The minimum pipe length is 5 ft for all applications.
6. Use 3 in. diameter vent termination kit for installations requiring 4 in. diameter pipe
—6—
MAXIMUM ALLOWABLE EXPOSED VENT PIPE LENGTH (FT) WITH AND WITHOUT INSULATION
IN WINTER DESIGN TEMPERATURE AMBIENT*
UNIT SIZE
060
080
100
120
WINTER DESIGN
TEMPERATURE
(°F)
MAX PIPE
DIAMETER
(IN.)
WITHOUT
INSULATION
WITH 3/8-IN. OR
THICKER INSULATION†
20
2
44
70
0
2
21
70
–20
2
20
57
20
2
55
55
0
2
30
55
–20
2
16
55
20
2.5
58
70
70
0
2.5
29
–20
2.5
14
67
20
2.5
40
40
0
2.5
38
40
–20
2.5
21
40
20
3
63
70
70
0
3
30
–20
3
12
70
20
3
70
70
70
0
3
38
–20
3
19
70
20
4
65
70
0
4
26
70
–20
4
5
65
* Pipe length (ft) specified for maximum pipe lengths located in unconditioned spaces. Pipes located in unconditioned space cannot exceed total
allowable pipe length as specified in Table 6.
† Insulation thickness based on R value of 3.5 (ft_ • °F• hr)/(Btu•in.)
—7—
CONDENSATE TRAP
FURNACE
DOOR
BLOWER SHELF
CONDENSATE
TRAP
CONDENSATE
TRAP (INSIDE)
FURNACE
DOOR
FURNACE
SIDE
4 78
FURNACE
SIDE
4
534
534
4
FIELD
DRAIN
CONN
ALTERNATE DRAIN
TUBE LOCATION
26 1 4
26 1 4
11 2
SIDE VIEW
CONDENSATE TRAP
DRAIN TUBE LOCATION
FIELD
DRAIN
CONN
FRONT VIEW
END VIEW
SLOT FOR SCREW
HORIZONTAL
APPLICATION
(OPTIONAL)
FRONT VIEW
HORIZONTAL
APPLICATIONS
DOWNFLOW AND ALTERNATE
EXTERNAL UPFLOW APPLICATIONS
UPFLOW APPLICATIONS
34
1⁄4 OD
COLLECTOR BOX TO
TRAP RELIEF PORT
11 2
1⁄2 OD
INDUCER HOUSING
DRAIN CONNECTION
34
5⁄8 OD
COLLECTOR BOX
DRAIN CONNECTION
71 8
SCREW HOLE FOR
UPFLOW OR DOWNFLOW APPLICATIONS
(OPTIONAL)
13 4
78
WIRE TIE
GUIDES
(WHEN USED)
21 4
FRONT VIEW
1⁄2-IN.
PVC OR CPVC
SIDE VIEW
A93026
ama
CERTIFIED
MEETS DOE RESIDENTIAL
CONSERVATION SERVICES
PROGRAM STANDARDS.
Before purchasing this appliance,
read important energy cost and
efficiency information available
from your retailer.
As an ENERGY STAR®
Partner, Bryant Heating &
Cooling Systems has determined that this product meets
the ENERGY STAR® guidelines for energy efficiency.
REGISTERED QUALITY SYSTEM
These products are engineered and manufactured
under an ISO 9001 registered quality system.
—8—
ACCESSORIES
CONCENTRIC VENT
B IN. DIA PVC
VENT/EXHAUST
F
E
C IN. DIA
13/16
11/2
D
A
B IN. DIA PVC
INTAKE/COMBUSTION AIR
A97110
DIMENSIONS (In.)
PART NO.
A*
B
C
D†
E
F
KGAVT0501CVT
33-3/8
2
3-1/2
16-5/8
6-1/4
5-3/4
KGAVT0601CVT
38-7/8
3
4-1/2
21-1/8
7-3/8
6-1/2
* Dimension A will change accordingly as dimension D is lengthened or shortened.
† Dimension D may be lengthened to 60 in. maximum. Dimension D may also be shortened by
cutting the pipes provided in the kit to 12 in. minimum.
ACCESSORY DOWNFLOW SUBBASE
;;;;
;;;;
LOCATING
TAB
1 1/4″ TYP
PLENUM
OPENING
B
D
1
2
3
A
4
LOCATING
TAB
4
3
2
A88207
A97427
Disassembled
FURNACE
CASING
WIDTH
C
FACTORY-SUPPLIED
FIELD-INSTALLED
INSULATION
1
Assembled
PLENUM OPENING*
FLOOR OPENING
FURNACE IN DOWNFLOW APPLICATION
A
B
C
D
HOLE NO.
FOR WIDTH
ADJUSTMENT
17-1/2
Furnace with or without CD5 or CK5 Coil
Assembly or KCAKC Coil Box
15-1/8
19
16-3/4
20-3/8
3
21
Furnace with or without CD5 or CK5 Coil
Assembly or KCAKC Coil Box
18-5/8
19
20-1/4
20-3/8
2
24-1/2
Furnace with or without CD5 or CK5 Coil
Assembly or KCAKC Coil Box
22-1/8
19
23-3/4
20-3/8
1
* The plenum should be constructed 1/4 in. smaller in width and depth than the plenum dimensions shown above.
—9—
MEDIA FILTER CABINET
25 5/8"
23 5/8"
24 3/8"
Opening with Flanges Bent
23 3/8"
23 1/8"
Opening
B Opening
A
Furnace Side
Duct Side
A00309
23 3/4"
Centerline Screw Slots
5 3/4"
Media/
Filter Cabinet
A
B
16"
17
16"
20"
21
20"
24"
25
24"
A00309
AIR DELIVERY—CFM (With Filter)*
EXTERNAL STATIC PRESSURE (In. wc)
UNIT SIZE
BRYANT
RETURN-AIR
SUPPLY
036060
1 side
or
bottom
036080
1 side
or
bottom
048080
1 side
or
bottom
04810
1 side
or
bottom
bottom
only
060100
both sides or
1 side and bottom
1 side only
bottom
only
060120
both sides or
1 side and bottom
1 side only
* •
•
•
•
SPEED
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
High
Med-High
Med
Med-Low
Low
High
Med-High
Med
Med-Low
Low
High
Med-High
Med
Med-Low
Low
High
Med-High
Med-Low
Low
High
Med-High
Med
Med-Low
Low
High
Med-High
High
Med-High
High
Med-High
Med
Med-Low
Low
High
Med-High
High
Med-High
1490
1190
1015
870
685
1605
1305
1135
990
805
1810
1420
1205
1035
805
1740
1500
1340
1195
2345
2110
1810
1480
1235
2425
2045
2305
2030
2385
2105
1785
1495
1250
2475
2085
2255
1985
1450
1180
1010
860
670
1560
1290
1125
980
780
1755
1385
1175
990
750
1705
1470
1315
1175
2265
2065
1795
1465
1205
2365
2025
2235
1995
2320
2060
1770
1470
1215
2435
2075
2190
1930
1400
1155
995
840
645
1510
1265
1110
965
745
1690
1350
1135
945
705
1660
1445
1300
1165
2195
2010
1770
1440
1180
2300
2000
2170
1950
2245
2005
1740
1450
1190
2385
2055
2115
1890
1345
1120
965
820
620
1450
1225
1080
930
700
1640
1305
1100
910
660
1615
1410
1270
1130
2110
1945
1725
1415
1155
2240
1965
2100
1905
2160
1945
1700
1420
1155
2320
2030
2045
1840
1275
1070
920
780
595
1380
1175
1030
880
660
1565
1260
1060
875
620
1570
1375
1235
1100
2035
1875
1680
1375
1115
2160
1910
2005
1835
2075
1880
1650
1385
1125
2260
1980
1965
1780
1190
1005
875
735
545
1300
1100
965
825
630
1495
1210
1010
840
585
1500
1330
1200
1070
1940
1800
1615
1330
1065
2080
1850
1925
1775
1975
1795
1600
1335
1085
2180
1930
1890
1720
1080
915
800
670
495
1195
995
885
760
575
1410
1145
960
790
540
1425
1280
1140
1030
1850
1710
1545
1260
1015
1980
1785
1825
1685
1870
1710
1525
1280
1040
2095
1865
1800
1645
960
810
715
580
420
1045
895
800
685
495
1330
1090
905
735
490
1355
1210
1095
975
1745
1615
1460
1190
950
1880
1695
1730
1600
1775
1620
1450
1220
985
1995
1785
1710
1560
Airflow shown is with factory supplied 1-in. washable filter.
A filter is required for each return air opening.
An airflow reduction of up to 7% may occur when using the factory-specified 4-5/16-inch wide, high efficiency media filter.
For best furnace efficiency when using the 4 5/16-inch wide media filter, adjust blower speed tap to near the mid-point of the rise range.
—10—
—11—
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE
UNIT MUST BE INSTALLED IN ACCORDANCE
WITH INSTALLATION INSTRUCTIONS
New
© 2001 Bryant Heating & Cooling Systems, 7310 W. Morris St., Indianapolis, IN 46231
—12—
PRINTED IN U.S.A.
Catalog No. 5235-200