Lectranator PP DIGITAL60 Residential : installation and operation manual

Add to my manuals
16 Pages

advertisement

Lectranator PP DIGITAL60 Residential : installation and operation manual | Manualzz

Pool Pilot

Digital 60

by LECTRANATOR SYSTEMS

INC.

Domestic

Chlorine Generating Device

Installation and Operation Manual

MODEL DIG60 REGISTRATION NUMBER 27843 PEST CONTROL PRODUCTS ACT

Maximum Output Equivalent To 0.88 Kg. Of Free Available Chlorine Per Day

One DIG60 Unit Can Treat a Maximum Of 190,000 Litres Of Swimming Pool Water

Controls Bacteria And Algae In Swimming Pool Waters

(For Indoor or Outdoor Use)

RETAIN MANUAL FOR FUTURE REFERENCE

C

NSF50

IMPORTANT

READ THE LABEL AND THIS MANUAL BEFORE INSTALLING & OPERATING

Notice to User: This control product is to be used only in accordance with the directions on this label. It is an offense under the Pest Control Products Act to use a control product under unsafe conditions .

Lectranator Systems Inc., 2770 – 24 Ave. N.E., Calgary, Alberta, T1Y 6V7

(PP DIG60 Residential English F i n a l N o v 2 0 0 4 )

Section 1a

– GENERAL PRODUCT INFORMATION

Pool Pilot

Digital

by

LECTRANATOR SYSTEMS

INC.

Record The Following Information

Installer: _____________________________Date of Installation: __________________________

Control Unit Control Unit

Model Number: DIG60______________ Serial Number: # ____________________________

Cell Cell

Model: # RC-13 Serial Number: # ____________________________

Customer Assistance…

HOTLINE: 1.866.517.7584 or 1.403.291.9845

FAX: 1.403.291.1023

Visit Us On The Internet @

www.lectranator.com

Manufactured for

Lectranator Systems, Inc.

2770 • 24 Avenue N.E.• Calgary, Alberta • Canada T1Y 6V7

Pool Pilot

Digital

by

LECTRANATOR SYSTEMS

INC.

1

Section 1b

– GENERAL PRODUCT INFORMATION

IMPORTANT SAFETY INSTRUCTIONS

READ AND FOLLOW ALL INSTRUCTIONS

INSTALLATION AND EQUIPMENT RELATED

Installation of all Pool Pilot Digital models:

When installing and using your Pool Pilot

Digital

Control Box, basic safety precautions must always be followed, including the following:

1.

Follow all aspects of the local and National Electrical Code(s) when installing your Control Box.

2.

During installation, mount your Control Box to ensure the least amount of direct exposure to rain, garden sprinkler water, direct sunlight or any corrosive environment.

3.

DANGER – Risk of electrical shock. Install Control Box at least 3 m (10 ft.) for 115VAC Units, from the inside wall of the pool or spa u sing non-metallic plumbing. 1.5 m (5 ft.) minimum distance for 230VA C Units.

4.

All field-installed metal components such as rails, ladders, drains or similar hardware within 3 m (10 ft.) of the spa or hot tub shall be bonded to the equipment grounding bus with copper conductors not smaller than 8.4 mm² (No. 8 AWG) in the

U.S.A. and 6.3mm² (No. 6 AWG) in Canada.

5.

WARNING – Maintain water chemistry in accordance with manufacturer’s instructions.

6.

DANGER – To reduce the risk of injury, do not permit children to use this product unless they are closely supervised at all times. Children should not use spas, hot tubs or pools without permanent adult supervision.

Equipment Related

115/230VAC, 50/60 Hz Models (fixed wiring)

1 A wire connector is provided on your Pool Pilot

Digital

to connect a minimum 8.4 mm² (No. 8 AWG) in the U.S.A. and

6.3mm² (No.6 AWG) in Canada solid copper bonding conductor between this unit and any metal equipment, metal enclosures of electrical equipment, metal water pipe or conduit within 1.5 m (5 ft.) of the unit.

2 A bonding terminal is located inside your Pool Pilot

Digital

. To reduce the risk of electrical shock, this terminal must be connected to the grounding means provided in the electrical supply panel with a continuous copper wire equivalent size to the circuit conductors supplying your Pool Pilot

Digital

.

3 A disconnection device from the power source, with a contact separation of at least 3mm (0.12 in.) in all poles, must be incorporated in the fixed wiring for permanently wired units.

4 The input voltage to the Pool Pilot

Digital

must match the 115/230VAC jumper terminals on the Circuit board, marked

“TRANSFORMER PRIMARY”, shown on Page 4.

SAVE THESE INSTRUCTIONS

2

Section 1c

– GENERAL PRODUCT INFORMATION

Table of Contents

Pool Pilot

Digital

by

LECTRANATOR SYSTEMS

INC.

Section 1 GENERAL INFORMATION

1a Product Information and Contact Numbers ........................................................... 1

1b

1c

Important Safety Instructions ................................................................................... 2

Table of Contents ....................................................................................................... 3

Section 2 INSTALLATION

2a

2b

Main Components ...................................................................................................... 4

Control Box Connections ........................................................................................... 5

Electrical Connections

Cell Cord and Tri-Sens or Connections

Remote ORP Connections

Cell and Manifold Installation.................................................................................. 6

Verification of Flow Switch Protection .................................................................... 6

Section 3 OPERATION

3a

3b

3c

Key Features – Display Panel.................................................................................... 7-9

Pool Water Preparation ............................................................................................ 10

Salt Requirement Chart

Start-Up Procedures

Monitoring and Maintenance.................................................................................... 11

Water Chemistry Parameters

Saturation Index

Section 4 SERVICE and MAINTENANCE

4a Control Box and Fuse Locations ............................................................................... 12

4b

Tri-Sensor Assembly .................................................................................................. 12

Cell ............................................................................................................................... 13

Removal and Inspection

Maintenance and Cleaning

Filter Backwashing..................................................................................................... 13

4c Parts Explosion........................................................................................................... 14

Section 5 TROUBLESHOOTING

5a Troubleshooting .......................................................................................................... 15

3

Section 2a –

INSTALLATION

Main Components

Tri-Sensor Assembly

DIG 60 = RC13Cell union

Flow In Flow Out to pool

Control Box

CONTROL BOX

converts incoming

AC power to a Low Voltage DC current, which energizes the Cell(s). Set the

Control Box

on a vertical surface away from excessive exposure to heat and moisture. Use the template to mark and drill the (4) mounting holes and insert the screws, leaving a ¼ in. gap. Hang the control box on the screws and level.

Remove the cover by following the steps on page 12 to access the mounting holes to tighten the screws.

Flow Bypass Manifold Assembly

ELECTROLYTIC CELL TRI-SENSOR ASSEMBLY

receives Low Voltage DC current from ensures that adequate flow, the Power Circuit Board, which initiates 94.5 L/min. (25 US Gallons/min.) the electrolytic process. This process minimum;

salt

, 2.8 – 3.2 gm/l converts ordinary table salt (Sodium

Chloride) to 100% Pure Sodium

Hypochlorite (Chlorine Bleach) or

Bromine (with the addition of Sodium

Bromide), which in turn sanitizes your pool or spa.

See page 10 for salt requirements.

(2800–3200 ppm) ideal range; and

water temperatures

, above

15.6

°

C (60

°

F) are satisfactory to prevent abusive conditions for the cell to operate. See page 12 for instructions to remove and inspect the tri-sensor assembly.

RATINGS:

Input Power: 115 VAC (3.0 AC amps)

230 VAC (1.5 AC amps)

Maximum Output:Equivalent to 0.88 kg (1.92 lbs) of free available chlorine/day

RC-13 Cell@ Power Level 3 (8 amps DC)

50/60 Hz Cell Life Expectancy: A minimum of 15,000 ampere/hours

Output Power: Cell Power 1 (5.0* DC amps) Agency Approvals: NSF, ETL us, ETL c, CE

Cell Power 2 (6.5* DC amps)

Cell Power 3 (8.0* DC amps) Internal Pump Relay is rated for 30-amp max.

*Indicates nominal amperage output. The dual axis controller will slightly vary the amps to optimize the power to the cell.

The cell and tri-sensor are located in a Flow Bypass Manifold Assembly. 3.6 m (12 ft.) of

Cell and Tri-Sensor cords

are provided with the unit. Ensure that the manifold is located within that distance from the control box with enough slack to allow for removal for service or maintenance.

The Digital display provides full information and diagnostic for maintenance and operation of your system. The programmable settings are retained on a microprocessor chip with the clock setting backed-up with a CR-2025 lithium battery.

CAUTION:

It is suggested to locate the cell downstream of all other equipment and on the pool return line only to avoid over-saturation conditions of your spa. For applications other than as recommended, contact the factory.

4

Section 2b

– INSTALLATION

Control Box Connections

Electrical Connections

Autopilot recommends that a licensed electrician or certified electrical contractor perform the electrical connections.

DANGER: ensure that the electrical panel or filter pump circuit breaker is turned OFF before wiring this unit.

Your

Pool Pilot™

Digital

Control Box comes pre-wired from the factory for 230VAC (1.5 amps max draw) and can also operate on 115 VAC, (3.0 amps max draw) at 50/60Hz. 1.8 m (6 ft.) of AC lead wires are provided with the unit and are located on the bottom base plate of the control box along with the Cell, Tri-Sensor and optional ORP Interface connections.

Converting to 115VAC

is accomplished by accessing the circuit board, rewiring, and attaching the included jumper as shown below. Remove the cover (see page 12) to access and ensure that the Jumper Connections on the circuit board marked

“TRANSFORMER PRIMARY” are matched to the LINE IN voltage. Follow all state/local codes for electrical installations.

? An additional jumper is provided with your

Installation Kit for 115VAC.

Location of the

Input Jumper Connections

Power Circuit Board

Transformer

230VAC

TAB 9

TAB 7

TAB 5

TAB 3

TAB 10

TAB 8

TAB 6

TAB 4

TRANSFORMER PRIMARY

115VAC

115VAC

TAB 9

TAB 7

TAB 5

TAB 3

TAB 10

TAB 8

TAB 6

TAB 4

TRANSFORMER PRIMARY

INNER CONTROL PANEL

230 VAC

FACTORY SETTING

115 VAC

WIRING DIAGRAM

Top terminals factory wired – do not disturb.

AC to PCB

AC Line OUT to Filter Pump

AC Line IN for Filter Pump

Ground

Lugs

#1 #2 #3 #4 #5 #6

Pump

Ground

Lug

Relay trigger

Bonding

Lug

Conduit

(to Low Speed) connector

AC

Line In

Plug

6-pin Tri-sensor

Plug connector

(Gr/Yel) (Br) (Bl)

Pool Pilot AC Line IN

Internal Relay

Pump Ground Lug

Load wires out to Single Speed Pump

(or Brown to High Speed)

Pump AC Line IN Pump AC Line OUT

AC LINE IN

(Wiring diagram also located on inside of cover)

:

provided

Pump conduit 2-pin ORP Cell Cord

Plugs Connector Connectors

CONTROL BOX BASE PLATE

For 230 VAC

; Brown (Br) = Line 1, Blue (Bl) = Line 2, Green w/Yellow Tracer (Gr/Yel) = Earth Ground

For 115 VAC

; Brown (Br) = Line, Blue (Bl) = Neutral, Green w/Yellow tracer (Gr/Yel) = Earth Ground

The AC Line IN wiring is pre-set for connection to the

LOAD SIDE

of your time clock, electronic controller switch or relay to work in conjunction with your circulation pump.

For control of your main circulation pump (single or two speed) through the

Pool Pilot

Digital’s

Internal Relay, cut and strip the pre-wired Line In wires, and jump #1 to #3 and #2 to #4 (Gr/Yel can be discarded). Route a new set of Pump AC Line IN wires from the circuit breaker/electrical panel into #3, #4 and Pump Ground Lug. Connect Pump AC Line OUT to #5, #6 and

Pump Ground Lug. This relay is rated for 30-amp max. Ensure that the Line In and Line Out wire sizes are according to electrical guidelines. Follow the menu program, pages 8 & 9, to program the

Digital

to your particular application. Ensure that the

Pool Pilot™

Digital

Control Box is properly bonded to a grounding circuit.

Cell Cord

.

Each Cell Cord contains (2) Banana Plugs that attach to the (2) Banana Jacks on the bottom of the Control Box.

Polarity does not matter. The other end of the cell cord has a three-position plug that connects to the cell in any direction. See page 13 for service instructions.

Tri-Sensor Cord

.

The Tri-Sensor Cord connects to the keyed 6-pin harness on the Control Box Base Plate. The opposite end of the cord connects to the Tri-Sensor Assembly with a locking ring quick connect. Align the grove and keyway on the connector and twist the locking ring to ensure a proper connection. Refer to the instructions on pages 12 & 14 for diagrams and additional instructions.

ORP Connection

.

When an ORP Chemical Controller is interfaced to your

Pool Pilot

™ Digital, the Chemical Controller will remotely control the sanitizer Output. Adjust the output level to 0% and connect the ORP controller to the 2-pin connector on the Control Box Base Plate. When the ORP is activated, the output will indicate ON with the display showing 0%.

WARNING: THE ORP CONNECTIONS ARE DRY CONTACT INPUTS, DO NOT ENERGIZE THESE

INPUTS! DAMAGE TO THE CONTROL BOX WILL OCCUR AND WILL VOID THE WARRANTY.

5

Section 2b

– INSTALLATION

Cell and Manifold Installation

Your Lectranator System is adaptable for use with the 13 blade ( RC-13) cell. The manifold must be located as the last accessory in the

POOL RETURN LINE

only. For special plumbing configurations, please contact your representative for assistance in locating the manifold.

Standard Manifold Assembly:

Bypass flow rate should be set at 94.5 L/min. (25 US Gallons/min.

)

.

Tri sensor

DIG60 = RC13 Cell

union

flow in flow out to pool

For other plumbing configurations, please contact your representative for assistance.

Verification of Flow Switch Protection:

It is important to

ANNUALLY

inspect and verify the safe and proper operation of the Tri-sensor’s Flow Switch protection device. We recommend following this procedure to verify that the flow switch is working as designed, which is to halt power from being sent to the cell in the presence of insufficient flow. A defective Flow Switch could cause serious personal and/or equipment damage. Using either a GOLF BALL or small plastic wrap (saran wrap, food wrap or zip lock bag), block off flow to the upper portion of the manifold by placing the golf ball in the strainer screen union or by wrapping the strainer screen with the plastic wrap and placing it back in the union and tightening. Operating the system on with this blockage should detect a

FLOW obstruction, indicated on the digital display and activating a red flashing CHECK SYSTEM light. Once this protection feature has been verified, remove the plastic wrap or golf ball, replace the strainer screen and resume operation. Turn the output dial to OFF and contact the factory if the flow switch protection is not working properly.

Golf Ball Plastic Wrap

CLEAN UNION

SCREEN

REGULARLY

OR

union

6

Section 3a

– OPERATION

Key Features

The Pool Pilot Digital display will show the

SANITIZER OUTPUT LEVEL

(in percent %) and whether the system is in

BOOST

or

SUPER-BOOST Mode

on the first line of the two line alphanumeric display. The second line will display the current

TIME

in either 12 or 24-hr mode, the

TEMPERATURE

in either Fahrenheit or Celsius, whether the cell is powered or not, shown as ON or OFF and

Polarity Direction

, shown as a “

.

” or blank. Easy touch pads allow for adjusting and programming the unit. A

Check System

visual alarm indicator works in conjunction with the display to advise of any problems. All Menu, Select and Pump functions as well as any “Error messages” will be displayed on both lines of the alphanumeric display.

POOL PILOT

Digital

S a n i t i z e r

100%

12:00P 80F

ON

Check

System

Boost Menu Select Pump

The

SANITIZING OUTPUT LEVEL

is adjustable from 0% (OFF) to 100 % (MAX) by pressing the

Up/Down

Arrows to obtain the desired Sanitizer Output Level. Little adjustment is needed once the initial setting is established.

Note: The Pool Pilot Digital does not test for sanitizer levels nor automatically adjust to maintain a desired sanitizer level. This is done by periodically testing the water and adjusting the output levels up or down, as needed.

The Pool Pilot Digital is des igned with an

AUTOMATIC TEMPERATURE COMPENSATION feature

, which automatically adjusts the output level setting based upon changes in seasonal water temperatures only. This unique feature conveniently compensates for warm (more sanitizer needed) or cold (less sanitizer needed) water conditions.

The

BOOST Button

increases the sanitizer output level to 100% for up to 72 hours, regardless of the initial output level setting. The sanitizing agent is produced, continually; throughout the normal On/Off cycles o f the pump and throughout all power line disturbances until the end of the cycle or when manually discontinued. When Boost is activated with

External

Timer

setting programmed, the time remaining for the boost cycle is held in memory and will start up in Boost mode until expired. With

Pump Program

or

2-Speed Pump

setting programmed, the time clock will be over ridden, producing sanitizer until the end of the boost cycle. The display will indicate the

BOOST Mode

on the second line when the boost

Button is pressed once. Once activated, the system will produce the sanitizing agent for 24 hours. The sanitizing agent can be produced for 72 hours by pressing and holding down the Boost Button for 5-seconds from the Boost-Off position. This is called the

SUPERBOOST Mode

. The display will indicate that the system has successfully entered the Super Boost mode.

To discontinue operation of Boost mode or Super Boost mode, pressed the Boost Button once more. The pool/spa pump must be turned on during the whole boost cycle. Do not let the pump run on a timer during that period.

The

Menu

and

Select Buttons

allows you to view the TEST mode, program the functions and time clocks. See the following pages for description of the menu tree.

* The

PUMP Button

allows you to over ride the pump timer to temporarily turn the pump on or off (depending on its status of operation), or to manually turn the pump off, indicated by the display “OFF FOR MAINTENANCE”. In “OFF FOR

MAINTENANCE” mode, the pump is prevented from restarting by the time clock and is only reactivated only by manually programming it to turn the pump back on. Not applicable with “EXTERNAL TIMER” selection.

The

CHECK SYSTEM

light will flash if there is a problem with the system. The nature of the problem will be indicated by the display through various error messages. See the Troubleshooting section, page 14, for repair solution.

FREEZE PROTECTION

:

this protective feature allows the pump, when programmed for One-Speed Pump, to override the program cycle and run continually (30-minute minimum) when the water temperature falls below 4.4°C (40

°

F). This prevents any damage to the PVC due to water expanding as it freezes.

7

Section 3a

– OPERATION

Key Features – continued

POOL PILOT

Digital

S a n i t i z e r

100%

12:00P 80F

ON

Check

System

Boost Menu Select Pump

The

MENU Button

allows you to enter the programming and monitoring functions

.

Use

UP/DOWN ARROW

and

SELECT

to scroll through the Main menu and Sub-menu:

Main Menu

1.0

Test Pool Pilot

2.0

Owner Options

3.0

Maintenance Menu

4.0

Installer Menu

5.0

Exit Menu Mode

SUB-MENUS

1.0 TEST POOL PILOT

The display will automatically cycle through this program, then return to normal operation. The display shows as follows:

1.1

Salt

in grams per liter (gm/l) or parts per million (PPM)

1.2

Add Salt

indicates the amount of salt needed to add to establish 3.0 gm/l (3000 ppm) based upon pool volume

1.3

Temperature

in Celsius or Fahrenheit.

1.4

Cell Volts

and

Amps

2.0 OWNER OPTIONS

Use

UP/DOWN ARROW

and

SELECT

to scroll through the sub-menu. After completing a step, it displays the next step:

2.1

English

/

Metric

: displays volume in gallons or cubic meters; salt additions in lbs or kg;

Back – Main Menu

(2.0)

2.2

Temperature Units

: displays the water temperature in

Fahrenheit

or

Celsius

;

Back - Main Menu

(2.0)

2.3

12/24-hour Time

: displays the current time in

12-hour Time

or

24-hour Time

units;

Back – Main Menu

(2.0)

2.4

Set Time of Day

: sets the time as follows:

Set Hours

;

Set Minutes

2.5 *

Pump Program 1

: allows you to program the pump on/off cycle through the on-board program

2.6 *

Pump Program 2

: allows you to program a secondary pump on/off cycle through the on-board program

* Only applicable with

Pump Config.

(4.6) selection of

One-Speed Pump

or

Two-Speed Pump

* Pump Program 1 or 2 will show the previous time set. Otherwise,

Not Programmed

will display,

then automatically step to display

-Prog. -Delete SELECT-No Change

Selecting

-Prog

steps to

Pump ON at Set Hours “12”:00 P; Pump ON at Set Mins 12:“00” P

then

Pump OFF at Set Hours “12”:00 P; Pump OFF at Set Mins 12:“00” P

2.7

Back – Main Menu

(returns to MAIN MENU)

8

Section 3a

– OPERATION

Key Features – continued

POOL PILOT

Digital

S a n i t i z e r

100%

12:00P 80F

ON

Check

System

Boost Menu Select Pump

Use

UP/DOWN ARROW

and

SELECT

to scroll through the sub-menu. After completing a step, it displays the next step:

3.1

Test

: same as 1.0 above plus cell

Amp-hrs

– then returns to Main Menu (3.0)

3.2-3.4

Set Time of Day

: same as 2.4 above

3.5

Force Reverse

: allows you to check cell volts and amps in the opposite direction (verifies reversing feature)

3.6

Set Reverse Time

: allows adjustable self-cleaning reverse rate of

2

,

4

,

8

or

16

hrs;

Back – Main Menu

(3.0)

Cell reversal is set on 4-hrs from the factory for ideal cell life. For conditions such as high calcium levels that can cause the cell to scale quicker than the self-cleaning cycle can control, change the setting to “2” hours.

For vinyl liner pools or optimum water chemistry balance according to the Saturation Index, see page 10, changing the

REVERSING cycle to “8” or “16” hours will extend the life of the ce ll.

If the

Reverse Time

is set to the “16” hours setting, check the cell weekly for the first month to ensure no scale develops. If there is scale development, change the setting to “8” hours.

Note

: changing the Reversing Time to “2” hours will affect the cell life. However, operating with scale development on the cell is more damaging to the life of the cell and changing the reversing time is suggested

3.7

Calibrate Salt

: allows you to calibrate the salt display. Contact the factory for calibration solution

3.8

Replace Cell

: Only used when replacing cells. May be used to zero the amp -hour counter. Consult Lectranator

Systems Inc. for details .

3.9

Back – Main Menu

(returns to MAIN MENU)

4.0 INSTALLER MENU

(Hold

Select

for 10 seconds to enter this mode)

Use

UP/DOWN ARROW

and

SELECT

to scroll through the sub-menu. After completing a step, it displays the next step:

4.1

English

/

Metric

: displays volume in gallons or cubic meters; salt additions as lbs or kg;

Back – Main Menu

(4.0)

4.2

Temperature Units

: displays the water temperature in

Fahrenheit

or

Celsius

;

Back - Main Menu

(4.0)

4.3

12/24-hour Time

: displays the current time in

12-hour Time

or

24-hour Time

units;

Back – Main Menu

(4.0)

4.4

Set Pool Volume

: displays the volume of the pool in either

Gallons

or

Cubic Meters

4.5

Set Cell Power

: allows you to set the

Power Level = 1, 2 or 3. Warning: Operating on “1” reduces cell power but extends cell life, “3” increases cell power but reduces cell life. Back – Main Menu

(4.0)

4.6

Set Pump Config

: allows you to select from

External Timer

,

One-Speed Pump

or

Two-Speed Pump

configuration

4.7- 4.9

Set Time of Day

: same as 2.4 – 2.6 above

4.10

Back – Main Menu

(returns to MAIN MENU)

Error Messages:

If the message

“Sanitizer Off”

is shown, the system h alts sanitizer production. This is shown when the unit is at rest or when the salt level is extremely low.

If the message

“Warning!”

is shown, the system will continue to produce sanitizer but at a reduced efficiency. This is associated with a warning message to check the system.

9

Section 3b

– OPERATION

Pool Water Preparation

Salt Requirements

It is important that with typical pools, a salt residual of 2.8 – 3.2 gm/l (2800 to 3200 ppm) be maintained at all times for peak efficiency.

NOTE:

Maintaining high salt levels above recommended range can contribute to corrosion of pool/spa equipment. Salt levels exceeding the recommended concentration can be reduced by diluting the pool/spa with fresh water.

The amount of salt required depends on the size of the pool and the present salt level. Broadcast the salt around the perimeter of the pool. DO NOT add salt directly into any skimmer or gutter device. As the salt is being added, we recommend running the circulation pump continually for 24 hours with the main drain opened. Brushing the salt towards the bottom main drain will assist in the dissolve rate and prevent possible staining with certain types of salt.

We recommend the use of

TABEX LectraClor™ or LectraClor Plus™

blended salt products. These products do not contain

Yellow Prussiate of Soda (YPS) or Iodine which could cause a localized tint to the water or brown staining on the cementitious finish if allowed to rest undissolved on the finish for extended periods of time.

LectraClor Plus™

is blended with the proper amount of stabilizer to maintain a proper level within the recommended range when added according to the salt chart on the box.

Granular Salt, Table Salt, Solar Salt or Water Conditioner Pellets can also be used but will have different dissolve rates. If the salt you use contains Iodine or YPS, constant brushing may help the dissolve rate and minimize staining due to the additives in the salt. Ensure that ANY salt you use contains a minimum purity of 99% Sodium Chloride (NaCl).

NOTE: Do not use Rock Salt due to its high levels of impurities.

TEST YOUR WATER FOR SALT LEVEL FIRST

with the provided salt test strips, and then use the chart below to determine the amount of salt to add.

SALT REQUIREMENT CHART

KILOS (LBS.) OF SALT NEEDED FOR 3000 PPM RESIDUAL

SALT Level

Before Addition

3,780

(1,000)

0 ppm

11.3 (25)

500 ppm

9.5 (21)

9,430

(2,500)

28 (63)

24 (53)

18,900

(5,000)

Pool Volume in Liters (US Gallons)

28,300

(7,000)

37,780

(10,000)

56,700

(15,000)

57 (126) 85 (175) 113 (252) 175 (378)

48 (106) 73 (147) 95 (212) 145 (318)

75,600

(20,000)

227 (504)

191 (424)

113,600

(30,000)

340 (756)

286 (636)

8.6 (19) 22 (48) 43 (96) 66 (133) 86 (192) 130 (288) 173 (384) 259 (576)

750 ppm

1000 ppm

1500 ppm

7.7 (17)

5.9 (13)

19 (43)

15 (33)

39 (86)

30 (66)

54 (119)

41 (91)

77 (172)

59 (132)

116 (258)

89 (198)

155 (344)

119 (264)

232 (516)

178 (396)

3.6 (8) 9.5 (21) 19 (42) 30 (56) 38 (84) 57 (126) 76 (168) 113 (252)

2000 ppm

2250 ppm

2.7 (6) 7 (15) 14 (30) 19 (42) 28 (60) 41 (90) 54 (120) 81 (180)

Note:

The above chart is based on 120 grams of salt added to 1000 Liters of water (1 lb. per 1,000 gallons) to increase your salt residual 120-ppm.

Start Up Procedures

Keep the Output Setting on your Pool Pilot Digital on 0% (OFF) until you get your water clear, blue and properly balanced.

1. After balancing your water chemistry according to the Water Chemistry Parameters shown on page 10, add the proper amount of salt (see Salt Requirement Chart above) and circulate 24-hours prior to starting your Pool Pilot Digital.

2. The following day set your Output Level to 50% and operate normally . Test water as required to conform with local health code. Raise or lower output control setting as needed.

3. Once your Output Level has been established, you will only need to adjust your level according to increased bather usage.

10

Section 3c

– OPERATION

Monitoring and Maintenance

Water Chemistry Parameters

-

VERY IMPORTANT NO TE!

Your Pool Pilot Digital is designed to provide Sanitizer on a daily basis. We recommend the following water chemistry ranges and periodic checks to monitor your systems efficiency. A lways follow local health requirements. Check the expiry date of the test kit as test results may be inaccurate if used after that date.

Daily Checks:

Free Chlorine:

1.0 – 3.0 PPM(pool)

Monthly Checks:

Calcium Hardness:

200 -300 PPM (Pool) 150-200(spa)

Salt Residual:

2800 – 3200 PPM

Or Bromine:

Free Chlorine:

Or Bromine pH:

1.0 – 3.0 PPM(pool)

3.0 – 5.0 PPM(spa)

3.0 – 5.0 PPM(spa)

7.2 – 7.8

Total Alkalinity:

100-120 PPM (Pool & Spa)

Cyanuric Acid:

30 – 100 P P M (Pool & Spa)

Saturation Index:

± 0.3 pH of saturation

Visual Cell Inspection

for wear, scale or debris

CHLORINE/BROMINE REQUIREMENTS:

During Peak Sanitizer Demand (rainy season or heavy bather usage) it may be necessary to increase your sanitizer level by increasing your Output Level setting and/or pump run time. Conversely, during

Low Sanitizer Demand, you can decrease your Output Level to a lower setting. For extremely Heavy Sanitizer Demand or to boost your sanitizer levels quickly, you can

Boost

the system or supplement with a Potassium Monopersulfate based shock.

NOTE: During cold-water conditions, below 15.6°C (60°F) , Sanitizer demand is reduced significantly.

For colder climate regions with freezing temperatures, contact your local pool professional for proper pool winterizing instructions.

CAUTION:

Excessive chlorine levels can cause corrosion damage to stainless steel rails, ladders, heater heat exchangers, light faceplates and other metallic equipment. Avoid over saturation of chlorine levels. The output setting must be sufficiently high to maintain the recommended chlorine residual in the swimming pool/spa water. Provincial and/or municipal regulation must be followed.

pH:

When your pH falls below the accepted range, your Sanitizer is used up very quickly and can be damaging to your equipment. For pH levels higher than the accepted range, your Sanitizer becomes much less effective and will work harder to keep your pool sanitized. Improper pH also contributes to the strong smell, red eyes, dry itchy skin and brittle hair conditions usually associated with “too much Chlorine”.

CALCIUM HARDNESS AND TOTAL ALKALINITY:

Your Pool Pilot Digital provides 100% pure sodium hypochlorite and does not affect the calcium hardness or total alkalinity levels. Maintain and balance only as needed.

CYANURIC ACID (STABILIZER/CONDITIONER):

This chemical goes by either trade name and allows your chlorine residual to last longer by protecting it from the UV degradation of the sun. In outdoor pools/spas with low or no Cyanuric acid, the chlorine being produced will be used up as quickly as it enters the pool. Check and maintain your cyanuric acid levels at the same time as your salt level, as these tend to deplete at the same rate. Regulations may exist regarding the use of cyanuric acid; please consult your local authority.

NOTE: For Bromine or indoor pools, it is not necessary to add stabilizer.

SALT RESIDUAL:

Your Pool Pilot Digital works most efficiently with salt levels between 2.8 – 3.2 gm/l (2800- 3200 ppm).

If it falls below 2.8 gm/l (2800 ppm), determine the salt level and adjust according to the SALT REQUIREMENT. Low salt will cause premature deterioration of the Cell blades. Maintaining high salt levels above recommended range can contribute to corrosion of pool/spa equipment. Salt levels exceeding the recommended concentration can be reduced by diluting the pool/spa with fresh water.

BROMINE RESIDUAL:

Along with the normal Salt level, add 0.45 kg (1 lb) Sodium Bromide (NaBr) per 7500 L (2000 gallons) of water. Your Pool Pilot Digital will now generate Bromine to sanitize your pool. Maintain your bromine level by checking your salt level. Once your salt falls below the recommended range, we suggest you add 0.45 kg ( 1 lb) sodium bromide with every 22.5 kg (50 lbs) of salt added. NOTE: Always use a registered or scheduled source of sodium bromide.

SATURATION INDEX (Si):

a formula used to ensure that your total water chemistry does not fall into a scale forming or corrosive condition. Either condition can cause premature damage to the Cell, equipment and exposed pool/spa surfaces.

Have your water professionally tested periodically according to the Saturation Index or use this chart to determine your water balance.

Si = pH + TF + CF + AF – Constant

Temperature TF Calcium Hardness CF

15.6C 60F

18.9C 66F

24.4C 76F

28.9C 84F

34.4C 94F

39.4C 103F

0.4

0.5

0.6

0.7

0.8

0.9

150

200

250

300

400

600

1.8

1.9

2.0

2.1

2.2

2.4

Total Alkalinity AF

75

100

125

150

200

250

1.9

2.0

2.1

2.2

2.3

2.4

TDS Constant

0 – 1000

1001 - 2000

2001 - 3000

12.1

12.2

12.3

_____

_____

Test your water for pH, Calcium Hardness, Total Alkalinity and TDS levels. Use the equivalent Factor in the Si equation.

Si = +0.3, balanced Si above + 0.3, scaling, staining or cloudy water conditions.

Si below -0.3, corrosive to metals, etches/deteriorates plaster finishes or skin irritating conditions.

DO NOT add pool/spa chemicals directly to the skimmer. This may damage the cell.

11

Section 3c

OPERATION (cont’d)

Additional notes: a) For proper sanitation, spa must be completely drained periodically. The number of days between COMPLETE SPA b) c)

DRAINAGE is equal to the volume of spa water in liters, divided by 10 times the maximum number of daily spa users.

Maximum spa usage temperature is 40°C (104°F). Duration in spa water at 40°C should not exceed 15 minutes. d)

Heavy use of the spa (excessive contamination) may require longer recovery times (A return to a minimum of 3 ppm chlorine/bromine). Recovery time may be reduced by adding a shock compound to the water.

Hot weather, heavy pool usage, and rain may require a higher output to maintain proper sanitizer residual.

Section 4a

–SERVICE and MAINTENANCE

CONTROL BOX

There are very few serviceable parts on the Pool Pilot Digital Control Box except the fuses. For any other problems with the

Control Box, please contact your representative or Authorized Dealer/Service Center.

To remove the Control Box Cover and access the fuses, follow these steps.

DANGER: TURN OFF THE AC POWER FROM THE CIRCUIT BREAKER OR PANEL BEFORE SERVICING

THIS UNIT.

POOL PILOT

Digital

Front of Unit

Control Circuit Board

’Wire Harness Connection

Inner Metal

F3 F2

Top Cover

Inside Top Cover

Cover

F1

Loosen (4) knobs

(you do not need to)

(remove these).

Lift off cover and disconnect Remove (3) screws and wire harness (Control Circuit lift off metal cover. board removes with cover).

Fuse Location and Ratings

F1 Main AC Power Fuse 6 Amps 250 VAC

Access is gained to electrical connections and fuses.

F2 Control Panel Circuit Board Fuse 3 Amps 250 VAC

F3 Cell Fuse 10 Amps 250 VAC

TRI-SENSOR ASSEMBLY

The Tri-sensor assembly tests for Flow, Salt and Water temperatures. A minimum flow rate of 94.5 L/min. (25 US

Gallons/min.) is required to activate the flow switch. As the water flow closes the paddle, a magnet activates a micro switch to verify proper flow. The Salt sensor protects against low salt levels and the temperature sensor protects against cold water temperatures. Both of which can contribute to accelerated cell failure.

Remove the Tri-Sensor as follows (with pump off):

Remove both screws from the side of the Tee Assembly. Firmly grip he Tri-Sensor assembly and twist to loosen the compression o -ring.

With the aid of large Channel-lok® (or similar) pliers, twist back and forth while removing the Tri-Sensor from the tee.

Inspect the thin metalic paddle for erosion and straightness.

Take care not to twist or tweek this paddle, which can cause inaccurate flow readings. Inspect the salt sensor blades for scale and debris and clean if necessary. See page 12 for cleaning instructions. Follow the directions for Manual Cell Cleaning.

Check the tri-sensor assembly for any damage to the plastic housing and replace if needed.

directional arrow screw(s) one on each side

12

Section 4b

–SERVICE and MAINTENANCE

Cell

The Cell is installed with Unions on each end of the cell to allow quick and easy removal. Loosen the unions and remove the cell from the plumb ing.

RC-13

Side View of Cell and Unions

VISUAL CELL INSPECTION:

The titanium Cell blades, seen inside the Cell body, should be straight and clear of any debris between the blades. Your Pool

Pilot Digital is designed to automatically self-clean scale build -up within the Cell. However, imbalanced water chemistry and certain conditions can cause a heavier scale build up that exceeds the self-cleaning capability and would need to be cleaned manually by the method described below.

Periodically inspect both ends of the cell.

A White Flaky or Crusty build-up on the edge or between the blades will prematurely deplete the life of the cell. Immediately clean the cell and determine the cause of scaling. See Troubleshooting Section, page 14.

End View of cell

Looking at the Titanium Blades

MANUAL CELL CLEANING:

With the Cell removed as described above, use a high-pressure hose nozzle to spray off as much loose, soft scale and debris as possible. Any remaining calcium scale can be treated with a mixture of one (1) part Muriatic Acid into four (4) parts water.

Mix the solution in a container high enough to cover the Cell blades. You may also use

TABEX LectraClean™ (

nonfuming/pre-mixed) cell cleaner, per label directions.

Remove the Cell cord and immerse the Cell so that the blades are completely covered in the solution for up to 15 minutes. An effervescences action indicates the calcium is being neutralized and cleaned. Drain the cell, flush with fresh water and re inspect. Repeat the immersion if necessary. Once the cell has been cleaned and rinsed; it may be re -installed in-line. BE

SURE THAT THE CELL “PINS” ARE CLEAN AND DRY BEFORE ATTACHING THE DC CORD FROM THE POWER

SUPPLY.

WARNING: ALWAYS ADD ACID TO WATER, never water to acid.

When replacing the cell, only use replacement cells having a label that clearly states that it is a replacement cell for the chlorine generating device Lectranator Digital Model DIG60, REGISTRATION NUMBER 27843, PEST CONTROL PRODUCTS

ACT.

NEVER USE ANY SHARP OR METALLIC OBJECTS TO REMOVE SCALE. Scraping or scratching the titanium blade’s edge or surface will allow chemical attack of the blade, cause premature failure of the Cell and will void your warranty.

Hacksaw Blades Screwdrivers Forks

FILTER BACKWASHING:

NOTE: The Control Panel Output setting must be set to 0% (OFF) when backwashing the filter.

Knives

13

Section 4c

–SERVICE and MAINTENANCE

Parts Explosion

Manifold Assembly:

(#941)

TRI-SENSOR

CELL w/ UNIONS

Manifold Union w/Strainer:

(#19065)

Union O-Ring (#19014)

Strainer (#19064)

Union Nut

MANIFOLD

UNION w/Strainer MANIFOLD BASE w/Check Valve

Electrolytic Cell:

(Cell Unions and Cord ordered separately)

12 ft. (3.6m) Cell Cord (# 952-1)

Union O-Ring (#19013)

Cell RC-13

Nut Half only (2 pcs) for 2 in. (50 mm) S x S Union Thread Half Only for 2 in. (50 mm) S x S Union

Tri-Sensor Assembly:

(Cord Ordered Separately)

Tri-Sensor

(#909-GO1

.

5)

Directional Flow Indicator

View of locking

Quick connect heads

12 ft. (3.6m) Tri-Sensor Cord (# 956-DIG)

Tri-Sensor O-Ring (#19028)

Temperature Sensor Post

Direction of Water Flow

Salt Sensor Blades

Flow Paddle

14

Section 5a

– TROUBLESHOOTING

TROUBLESHOOTING

PROBLEM CAUSE

1) Insufficient Sanitizer Production.

A)

The test kit reagents or test strips are old or expired.

SOLUTION

A)

Retest with new Reagents or Strips.

B)

The unit is set too low in relation to sanitizer demand.

B)

Increase the Sanitizer % output.

C)

The circulation run time is insufficient.

C)

Increase your pump run time.

D)

The bather load has increased.

D)

Same solution as

(B)

and/or add a Non-Chlorine Shock containing Potassium Monopersulfate to supplement.

E)

The body of water being sanitized leaks.

F)

Low Salt.

E)

Repair the leak and rebalance as needed.

F)

Check the residual salt level and adjust as needed.

G)

H)

“Cell Type” selection not matched to the cell installed.

Sanitizer loss due to intense sunlight

2) Scale Build-up within the Cell.

G)

H)

Follow the INSTA LLER SETUP instructions, see page 8.

Check your stabilizer level and adjust if needed.

A)

The water being sanitized contains high pH, total alkalinity and calcium hardness levels.

A)

Calculate Langelier’s Index to assure balanced water.

Adjust chemicals and clean the Cell. See pages 12 & 13.

(Cell scales within 2 – 3 weeks)

B)

Power Supply not reversing polarity.

(Cell constantly scales within 3 – 5 days)

B)

Contact Representative or Authorized Service Centre.

3) DC Plug and Cell Terminals Burned.

A)

The Cell terminals are wet due to a leaking cell body.

A)

Contact Representative or Authorized Service Centre.

B)

The Cell plug is not securely pushed onto the cell terminals, allowing moisture to seep into the plug.

B)

Ensure the Cell cord plug is pressed completely onto the

Cell terminal. Check the terminals and clean with a dry cloth to remove all dirt and corrosion.

4) Premature Cell Failure (Requires Replacement Cell).

A)

Abnormally high Cell usage due to an insufficient

Stabilizer (Cyanuric acid) level.

A)

Check the stabilizer level and adjust to recommended levels.

B)

Excessive Scale/Debris in the Cell.

B)

See Section 2 above.

C)

“Cell Type” selection not matched to the Cell installed.

C)

Follow the INSTALLER SETUP instructions, see page 8.

5) White Flakes in the Water.

A)

This occurs when excessive calcium hardness is present. Usually due to water chemistry imbalance.

A)

Adjust your water chemistry, visually inspect Cell for scale build-up and clean the cell as described on pages 11 & 13.

6) No Power to the Control Box.

A)

Internal Fuse blown.

B)

Circuit Breaker tripped.

7) SERVICE Light Flashing.

MESSAGED DISPLAYED

“CHECK FLOW”

A)

Tri-Sensor Defective.

A)

B)

Check and replace fuse. See page 11.

Check the power going to the Control Box. Reset the

Circuit Breaker.

A)

Contact Representative or Authorized Service Centre.

B)

Insufficient Flow(Min 94.5 L/min.)(25 US Gallons/min)

B)

Ensure your Filter and Cell are clean of debris.

Check all valves that might divert flow away from the cell.

MESSAGE DISPLAYED

“LOW AMPS – CELL?”

A)

Extremely Low Cell Amperage.

A)

Cell heavily scaled. If cell is already clean, replace cell.

B) Extremely

Low Salt Level.

C)

The Cell Cord is Loose

B)

Salt level below 1,5 gm/l (1500 ppm).

C)

Ensure that the cord is firmly pressed into the cell and the wires properly connected into the banana plugs.

D)

Power Supply has failed.

D)

Contact Representative or Authorized Service Centre.

MESSAGED DISPLAYED

“CHECK/CLEAN CELL” (Sanitizer still producing)

A)

Excessive Cell Voltage

A)

Check cell for calcium or scale build-up.Clean as req’d.

Water Temperature too cold. Raise above 15.6

°

C/60

°

F

MESSAGE DISPLAYED

“LOW SALT - ADD XXX lbs (or kg)”

A)

Salt level Low (below 2,2 gm/l/2200 ppm).

A)

Add the amount of salt shown on the displays

15