Controls / Functions / International Symbols
TPI offers a
Controls and Functions complete line of…
CO, Combustibles &
Combustion (CEA)
Refrigerant Leak
Detectors
Digital Manometers
Temperature Contact
& IR Instruments
IAQ: Air Flow /
Humidity
Handheld
Oscilloscopes
Digital Multimeters
& Clamp-on Meters
Accessories & Kits
Test Products
International, Inc.
Headquarters:
9615 SW Allen Blvd.
Beaverton, OR 97005
USA
503-520-9197
Fax: 503-520-1225 email: [email protected]
Push Buttons
REC
COMP
REL%
Range
EDIT
Activates back light for LCD (automatically turns off after approx. 70 sec.)
Activates the Min/Max/Ave mode
Activates the Compare mode
Activates the REL% mode
Activates manual ranging
Activates the EDIT mode for Compare and
HOLD
Relative% functions
Activates two-hold data-hold mode
Activates special dual functions on LCD.
(Min/MAx time references)
ON/OFF Turns DMM on and off
Data-H Activates the data hold function
Rotary Switch
- - -
V Selects the DCV function. Select the best range for the voltage to be measured
Selects the ACV function. Select the best
- - -
A
OFF
- - mV
- - -
V range for the voltage to be measured
Selects the DCA function. Select the best range for the current to be measured
Selects the ACA function. Select the best range for current to be measured
Selects resistance, diode, or continuity function
Turns the instrument off
Selects the DC mV function
Selects the DCV function
Selects the ACV function (Push the yellow button to display frequency of measured voltage on lower display a
~
- - DC (DIRECT CURRENT)
Input Jacks
A Red test lead connection for current measurements on the 2 and 10 ACA and
DCA functions mAµA Red test lead connection for current measurement on the mA and A DCA
COM and ACA functions
Black test lead connection for all
V functions
Red test lead connection for all OHM,
DCV, and ACV functions
International Symbols
CAUTION: RISK OF ELECTRICAL SHOCK
AC (ALTERNATION CURRENT)
Rotary Switch cont’d
Ω
- - mA
- - -
A
Hz
Selects the diode test function
Selects resistance function. (Push the yellow button to activate continuity buzzer)
Selects the DC mA function
Selects the DCA function (10A max.)
Selects the ACA function (10A max.)
Selects the AC mA function
Selects the Capacitance function
Selects the Frequency function
_
~
GROUND
DOUBLE INSULATION
EITHER DC OR AC
!
Test Products
International, Ltd.
342 Bronte St. South
Unit 9
Milton, Ontario L9T
5B7
Canada
905-693-8558
Fax: 905-693-0888 email: [email protected]
REFER TO INSTRUCTION MANUAL
Distributed By:
FUSE
DMM
FAQ
1. Is there a way to measure higher current with a TPI
DMM?
TPI DMMs (except the 120 and 126) have the capacity to read up to 10A
AC/DC. Optional adapters are available for all models to increase the current range. Our shunt adapters are available to increase the range up to 1,000A AC/DC.
2. What other adapters are available for TPI DMMs?
Various adapters including carbon monoxide (A771), pressure
(A620/630), and clamp-on low current (A254) are available. Contact
TPI for additional information.
3. Which of the TPI DMMs will measure temperature?
All TPI DMMs can measure temperature by using the optional A301 K-Type thermocouple temperature adapter.
4. Which TPI DMMs can measure DC millivolts?
All TPI DMMs measure millivolts.
Models are available with 1 or 0.1
millivolt resolution.
5. Which TPI DMMs can measure DC microamps?
The TPI 126, 133, 135, 153, 163, 183,
190, 194, 196, and 440 all have this capability.
6. Which TPI DMMs will measure capacitance?
The TPI 135, 183, 190, 192, 194, and
440 all have this capability.
Test Products
International UK Ltd.
Longley House, East Park
Crawley, West Sussex
RH10 6AP England
Tel: +44 (0)1293 561212
Fax: +44 (0)1293813465 [email protected]
To learn about the entire line of TPI products visit:
www.tpi-thevalueleader.com
L TAW DMM -1005
Copyright © 2005 Test Products International, Inc.
7. What is continuity?
Continuity refers to a test performed on wires and circuits to see if a break(open) exhists. If the wire or circuit is continuous, the resistance reading will be at or near zero.
The continuity range on a meter provides audible indication of a continuous circuit, allowing quicker tests without having to take your eyes off the circuit or wire under test.
DMM Selection Guide
Palm Size
100, 120, 122, 126
Full Size
133, 135, 153, 163,
183, 190, 192, 194,
196
True Rms
183, 190, 192, 194,
440
50,000 Count High
Resolution
190, 192, 194, 196
Wave Form Display
440
Process Loop
Calibration
196
100 120 122 126 133 135 153 163 183 190 ~ 196 440
1. Determine the maximum over voltage installation category (CAT I ~ CAT IV) the multimeter will be used in and narrow your choice to those meters meeting the requirement. The Category rating for each meter is listed on page 2 in the specifications table.
2. Narrow your choice by selecting meters with the features required for your intended applications. For example, if your applications require a CAT III meter with true RMS, frequency, and RS232 output capabilities, the TPI 183 or TPI190 would be good choices. See applications listed below.
3. Finally, select a meter with enough range, accuracy, and resolution for the tests you will perform. For example: the TPI 183 and the TPI 190 meet your application needs, but you require precision high-resolution measurements. Then the 50,000 count TPI 190 would be the better choice.
True RMS Plus
Waveform
440
APPLICATIONS
The
Value
Leader
™
See page 3 inside for ranges, specifications, and features.
Application
Thermocouples in furnaces and gas appliances •
Heat anticipator current in thermostats •
Line voltages
Control voltages •
•
Flame safety control current
Heating element resistance
Compressor winding resistance
Contactor and relay coil resistance •
•
•
•
Motor run and start capacitors
Use bar graph to indicate rapid fluctuations
Continuity of wiring
Measure frequency on control and line voltage •
•
•
•
Record minimum and maximum of measurements •
Measure temperature * •
Measure True RMS of distorted or non-linear signals •
Measure line current up to 10 amps •
Test continuity of circuit breakers and fuses
Measure voltage of direct drive DC motors
Measure power supply voltage
Measure power supply current
High resolution, high accuracy
High resolution, high accuracy
•
• Category IV tests
Process loop calibration
Power Quality
Audio
Video
Logic Tests
Waveform Display
•
•
•
•
•
•
•
•
•
•
•
Market
HVACR Electrical Electronic Industrial
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Function
•
•
•
DCmV
ACA
ACV
ACV/DCV
DCuA
Ohms
Ohms
Ohms
•
•
•
•
•
•
•
•
•
CAP
ALL
Ohms
Hz
REC
DCV
ACV/ACA
ACA
Ohms
DCV
ACV/DCV
ACA/DCA
•
•
•
•
ALL
ALL
ACV/DCV mA Out
ACV/ACA
ACV/ACA
ACV
LOGIC
•AC+DCV+A
* Requires either the A301single input or A312 dual input temperature adapters
100 120 122 126 133 135 153 163 183 190 192 194 196 440
* *
TPI DIGITAL MULTIMETER TERMINOLOGY
CATEGORY RATINGS
>> Category I: Usually electronic equipment or equipment where measures have been taken to limit transient over voltages.
>> Category II: Single phase loads like appliance personal computers, television sets, and other household loads. Outlets located more than 30 feet from a CAT III source or more than 60 feet from a CAT IV source.
>> Category III: Distribution level fixed installations like distribution panel devices, short branch and feeder circuits, three phase loads, and single phase commercial lighting.
>> Category IV: Equipment and lines located on the power line side of a service panel or where a low voltage connection is made to utility power batter y operated
CAT I CAT II
three-phase motor/ conveyor
CAT III
underground ser vice
CAT IV
T erminology
>> Agency Approval: Test equipment with the CE or UL mark have passed through tests and are designed with operators safety in mind.
>> Record Mode: Record and display the minimum and maximum readings measured. This feature is useful when looking for trends over a long period of time.
>> Auto Range: Meter automatically selects the appropriate range after the function has been selected.
>> Backlight: Feature allowing the display to be illuminated for easier viewing in low light conditions.
>> Basic DC Accuracy: Important specification affecting the overall accuracy of all functions on a DMM.
>> Resolution: A measurement of how small of a signal a meter can display. This specification must be taken into account with accuracy to determine the overall capability of a DMM.
>> True RMS: Allows accurate measurement of non-sinusoidal AC voltage and current found in many control and switching power supply circuits.
>> Analog Bar Graph: Provides the ability to see rapidly changing signals too fast for the digital display to see.
>> Triple Display Simultaneosly display more than one reading at the same time. This feature is useful when measuring AC volts beacuse the frequency can be displayed at the same time without having to switch ranges
>> Sleep/Auto Off: Automatically powers instrument down after 30 minutes of inactivity to preserve battery life. Meters with sleep mode will still acquire data during this time
>> Data Hold: Freezes the reading on the display. This feature is useful when recording readings on paper or when in hard to see locations.
Triple display meters can hold two readings on the display at the same time.
>> Input Impedance: Total resistance of the meter as measured at the input terminals. Meters with high impedance, 10M Ω or more, cause negligible loading of the circuit under test. This is important because circuit loading can adversely influence the displayed reading and can cause damage to the circuit under test.
>> Record Mode: Record and display the minimum and maximum readings measured. This feature is useful when looking for trends over a long period of time.
>> Relative Mode: Displays measured value as a percentage of the stored value. This feature is useful for component checking.
>> Compare Mode: Compares measured value with stored value. This feature is useful when component matching.
>> Audible Continuity: Audible beep indicating a complete circuit connnection
>> RS-232 Output: Transfer data directly to a PC while performing tests
>> Process Output: Supply 0 ~ 24mADC for testing current loops and current loop devices
>> Waveform Display: The ability to see the actual waveform under test. This feature is useful for determining the quality of the input signal.
>> Duty Cycle: The total “on” time of the device under test. This feature is useful in preventing component overheating
>> Pulse Width: Measurement of the duration of a pulse. This feature is useful when testing pulse width modulation drive motors.
>> Logic Test: Measurement transitions of logic circuits. This feature is useful when testing CMOS and TTL logic circuits.
>> Two Hold System: Meters with this feature can hold two readings on the display at the same time
>> Digits: Total number of digits that can be displayed. For example, a
3½ digit meter can display a maximum of 1,999. A 3¾ digit meter can display a maximum of 3,999. This means the 3¾ digit meter has beter resolution capability.
>> Counts: Total number of display steps a meter has. This is determined by adding one to the maximum display value. For example, a 3½ digit meter can display a maximum of 1,999 and therefore has
2,000 count capability. Both digits and counts must be taken into account when determining resolution. In general, the more counts a meter has the higher the resolution will be.
TPI DIGITAL MULTIMETER SPECIFICATIONS
DMM Model Part Number
100 120 122 126 133 135 153 163 183 190 192 194 196 440
Range Selection
Manual
Auto*/Manual
Display Specifications
2,000 Count
•
•
•
•
•
•
•
•
•
• • • • • • • •
3,260 Count
4,000 Count
4,000 Count w/
Triple Display
4,000 Count w/
• • • •
•
•
•
Waveform Display
50,000 Count
Triple display
• • • •
Analog Bar Graph
Backlight
Basis Features
• •
•
•
•
•
•
•
•
•
• •
AC Volts
DC Volts
AC Amps
DC Amps
Resistance
Diode Test
Audible Continuity
Additional Features
True RMS
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Frequency
Capacitance
Inductance
Data Hold
Two Hold System
Min/Max Record
Relative Mode
Compare Mode
RS-232 Output
Oscilloscope Functions
Duty Cycle
Pulse Width
Logic Test
• • •
•
•
•
• •
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Process Output (0~24mA)
Sleep Mode/Auto Off
Range & Resolution
• • • • • • •
•
• •
Basic DC Accuracy
DC Voltage (maximum)
Input Impedance
Resolution (maximum)
AC Voltage (maximum)
Input Impedance
Resolution (maximum)
DC Amps (maximum)
Resolution (maximum)
AC Amps (maximum)
Resolution (maximum)
Resistance (maximum)
Resolution (maximum)
Frequency (maximum)
Resolution (maximum)
Capacitance (maximum)
Resolution (maximum)
0.5%
600V
10M Ω
1mV
600V
10M Ω
1mV
-
-
-
-
40M Ω
0.1
Ω
-
-
-
-
-
-
-
-
-
-
2K Ω
1 Ω
-
-
0.5%
600V
10M Ω
1mV
600V
10M Ω
100mV
-
-
-
-
-
-
-
-
2K Ω
1 Ω
-
-
0.5%
600V
10M Ω
1mV
600V
10M Ω
1mV
-
-
-
-
0.3%
600V
10M Ω
0.1mV
600V
10M Ω
1mV
400mA
0.1mA
400mA
0.1mA
40M Ω
0.1
Ω
-
-
-
-
-
-
0.5% 0.5% 0.3% 0.5% 0.3% 0.05% 0.05% 0.05% 0.05% 0.05%
1,000V 1,000V 1,000V 1,000V 1,000V 1,000V 1,000V 1,000V 1,000V 1,000V
10M Ω
0.1mV
750V
10M Ω
0.1mV
10M Ω
0.1mV
750V
10M Ω
0.1mV
10M
0.1mV
750V
10M
1mV
Ω
Ω
10M
10M
1mV
Ω
0.1mV
750V
Ω
10M
10M
1mV
Ω
0.1mV
750V
Ω
10M
10M
Ω
0.001mV 0.001mV 0.001mV 0.001mV 0.1mV
750V
Ω
100µV
10M
10M
Ω
750V
Ω
100µV
10M
10M
Ω
750V
Ω
100µV
10M
10M
Ω
750V
10M Ω
1,000V
Ω 1.11MΩ
100µV 1mV
10A
0.1µA
10A
0.1µA
20M Ω
0.1
Ω
-
-
-
-
-
-
10A
0.01µA
10A
0.01µA
40M Ω
0.1
Ω
-
-
20,000µF
0.1µF
-
-
10A
0.1µA
10A
10A
0.1µA
10A
10A
0.1µA
10A
10A
0.01µA
10A
10A
0.01µA
10A
10A
0.01µA
10A
10A
0.01µA
10A
10A
0.1µA
10A
0.1µA 0.1µa 0.1µA 0.01µA 0.01µA 0.01µA 0.01µA 0.1µa
40M Ω 32.6M
Ω 40M Ω
0.1
Ω 0.1
Ω 0.1
Ω
-
50M
0.01
Ω
Ω
50M
0.01
Ω
Ω
50M
0.01
Ω
Ω
200KHz 500KHz 500KHz 500KHz
0.01Hz
0.001Hz
0.001Hz
0.001Hz
50M
0.01
-
-
Ω
Ω
40M
0.1
Ω
Ω
2MHz
0.01Hz
-
-
-
-
-
-
-
-
10,000µF 20,000µF 100µF 20,000µF
0.01µF 0.001µF 0.1nF
0.001µF
-
-
-
500mH
0.01mH
-
-
-
-
-
-
400µF
100pF
-
Inductance (maximum)
Resolution (maximum)
Agency Approval
CE IEC 1010
CULus 3111
CAT III CAT III CAT III CAT III
600V 600V 600V 600V
CAT II
1,000V /
CAT II
1,000V /
CAT II
1,000V /
CAT II
1,000V /
CAT II
1,000V /
CAT II
1,000V /
CAT II
1,000V /
CAT III
1,000V /
CAT II CAT II
1,000V / 1,000V /
• •
*the range selection for the 100 DMM is auto only
•
CAT III CAT III CAT III CAT III CAT III CAT III CAT III CAT IV CAT III CAT III
600V 600V 600V 600V 600V 600V 600V 600V 600V 600V
• • • • • • •
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•