technical data
Outdoor Units,
Pair Application
Split
Sky Air
air conditioning systems
RXG-E2V1B
• Outdoor Units • R-410A • RXG-E2V1B
TABLE OF CONTENTS
RXG-E2V1B
1
Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
2
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Nominal Capacity and Nominal Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3
3
4
3
Electrical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
4
Capacity tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Cooling/Heating capacity tables
5
..................................... 7
Dimensional drawing & centre of gravity . . . . . . . . . . . . . . . . . . . . . . . . 9
Dimensional drawing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Centre of gravity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
6
Piping diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
7
Wiring diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Wiring diagram
8
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Sound data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Sound pressure spectrum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
9
13
Operation range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
• Split Sky Air • Outdoor Units
1
• Outdoor Units • R-410A • RXG-E2V1B
1
i n y U k B S 1 r V o A2t o 0E i d 1- l t4G pu-X RS•O
•
Features
Outdoor units for pair application
Outdoor units are fitted with a swing compressor, renowned for its low
noise and high energy efficiency
1
2
• Split Sky Air • Outdoor Units
•
Daikin outdoor units are neat and sturdy and can be mounted easily
on a roof or terrace or simply placed against an outside wall.
• Outdoor Units • R-410A • RXG-E2V1B
2
Specifications
2-1 NOMINAL CAPACITY AND
NOMINAL INPUT
For
combination
indoor units +
outdoor units
Indoor Units
Nominal
Capacity
Cooling
Heating
For
combination
indoor units +
outdoor units
Standard
kW
2.5
3.5
Maximum kW
3.0
3.8
Minimum
kW
1.3
1.4
Standard
kW
3.4
4.2
4.5
5.0
Cooling
4.03
3.30
COP
Heating
4.15
Energy
Labeling
Directive
Cooling
A
Heating
A
Cooling
310
530
FTXG25EV1BS
FTXG35EV1BS
kW
1.3
1.4
Standard
kW
2.5
3.5
3.8
Maximum kW
3.0
Minimum
kW
1.3
1.4
Standard
kW
3.4
4.2
Maximum kW
4.5
5.0
Cooling
4.03
3.30
COP
Heating
4.15
Energy
Labeling
Directive
Cooling
A
Heating
A
EER
Casing
Colour
Dimensions
Unit
Packing
310
530
RXG25E2V1B
RXG35E2V1B
Ivory White
Height
mm
550
550
Width
mm
765
765
285
Depth
mm
285
Height
mm
589
589
Width
mm
882
882
Depth
363
mm
363
kg
32
32
Packed Unit
kg
38
38
mm
805
805
Length
Nr of Rows
Fin Pitch
mm
Nr of Stages
2
2
1.40
1.40
24
Tube type
Fin
Fan
Type
WH fin
Propeller
Quantity
Motor
1
1
Cooling
m³/min
31.30
31.3
Heating
m³/min
28.10
28.1
Quantity
1
Model
Motor
Fan
24
Hi-Xa(7)
Type
Air Flow Rate
(nominal at
230V)
2
3.72
Unit
Dimensions
3
3.72
Minimum
TECHNICAL SPECIFICATIONS
Heat
Exchanger
1.4
1.3
Annual energy consumption kWh
Weight
FTXG35EV1BW
Maximum kW
EER
Heating
2-2
FTXG25EV1BW
kW
Indoor Units
For
combination
indoor units +
outdoor units
RXG35E2V1B
Minimum
Annual energy consumption kWh
Nominal
Capacity
RXG25E2V1B
1
D23A-28
Speed
(nominal)
Cooling
rpm
810
810
Heating
rpm
810
810
Motor
Output
W
35
35
• Split Sky Air • Outdoor Units
3
• Outdoor Units • R-410A • RXG-E2V1B
2
2-2
Specifications
TECHNICAL SPECIFICATIONS
Compressor
RXG25E2V1B
Quantity
Motor
1
Model
1YC23NXD#A
Type
2
Operation
Range
Cooling
Heating
Sound Level
(nominal)
Cooling
Heating
Refrigerant
Hermetically sealed swing compressor
Motor
Output
W
600
600
Min
° CDB
10.0
10.0
Max
° CDB
46.0
46.0
Min
° CWB
-15.0
-15
Max
° CWB
20.0
20
Sound
Power
dBA
61.0
62.0
Sound
Pressure
dBA
46.0
47.0
Sound
Pressure
dBA
47.0
48.0
kg
1.00
Type
R-410A
Charge
1.0
Control
Refrigerant Oil
Motor operated expansion valve
Type
FVC50K
Charged Volume
Piping
connections
l
0.4
0.4
Liquid (OD)
Diameter
(OD)
mm
6.35
6.35
Gas
Diameter
(OD)
mm
9.5
9.5
Drain
Diameter
(OD)
mm
18
18
Piping Length
Maximum m
Additional Refrigerant
Charge
kg/m
Max. internunit level
difference
m
20
20
0.02/>10
15.0
15.0
Heat Insulation
Standard
Accessories
RXG35E2V1B
1
Both liquid and gas pipes
Item
Installation manual
Quantity
1
1
Item
Drain plug
Quantity
1
Notes
1
Nominal cooling capacities are based on : indoor temperature : 27°CDB, 19°CWB, outdoor temperature : 35°CDB,
equivalent refrigerant piping : 7.5m, level difference : 0m.
Nominal heating capacities are based on : indoor temperature : 20°CDB, outdoor temperature : 7°CDB, 6°CWB,
equivalent refrigerant piping : 7.5m, level difference : 0m
Sound levels are measured in an anechoic room
Sound pressure level is a relative value, depending on the distance and acoustic environment. For more details,
please refer tosound level drawings of this chapter.
The sound power level is an absolute value indicating the power which a sound source generates.
2-3
ELECTRICAL SPECIFICATIONS
Power Supply
RXG25E2V1B
Name
Phase
Frequency
Current
Wiring
connections
Hz
1
1
50
50
Voltage
V
230
230
Cooling
Nominal
running current (A)
(RLA)
Heating
(A)
A
3.26
4.76
A
4.36
5.06
Starting current (cooling/
heating)
A
4.5
5.2
Quantity
3
3
For connection Quantity
with indoor
Remark
4
For Power
Supply
Power Supply Intake
4
RXG35E2V1B
V1
4
included earth wiring
Outdoor unit only
• Split Sky Air • Outdoor Units
• Outdoor Units • R-410A • RXG-E2V1B
3
Electrical data
RXG+FTXG-E
Representative unit combination
Indoor unit
Outdoor unit
FTXG25EV1BW
RXG25E2V1B
FTXG25EV1BS
RXG25E2V1B
Hz-volts
50 - 220
50 - 230
50 - 240
50 - 220
50 - 230
50 - 240
Power supply
Voltage range
Comp.
MCA
MFA
RHz
Max. 50Hz 264V
Min. 50Hz 198V
12
15
49
Max. 50Hz 264V
Min. 50Hz 198V
12
15
49
OFM
RLA
3.3
3.2
3.1
3.3
3.2
3.1
W
35
35
IFM
FLA
0.23
0.22
0.21
0.23
0.22
0.21
W
FLA
0.52
0.50
0.48
0.52
0.50
0.48
40
40
3
3D045220B
SYMBOLS
NOTES
MCA
: Min. Circuit Amps (A)
MFA
: Max. Fuse Amps (A)
RLA
: Rated Load Amps (A)
OFM
: Outdoor Fan Motor
IFM
: Indoor Fan Motor
FLA
: Full Load Amps (A)
W
: Fan Motor Rated Output (W)
RHz
: Rated operating frequency(Hz)
• Split Sky Air • Outdoor Units
1
RLA is based on the following conditions:
Indoor temperature 27°CDB/19°CWB
Outdoor temperature 35°CDB
2
Maximum allowable voltage variation between phases is 2%
3
Select wire size based on the larger value of MCA.
4
Instead of fuse, use circuit breaker
5
For more details concerning conditional connections, see
http://extranet.daikineurope.com, select ’’E-Data Books’’.
Finally, click on the document title of your choice.
5
• Outdoor Units • R-410A • RXG-E2V1B
3
Electrical data
RXG+FTXG-E
Representative unit combination
Indoor unit
Outdoor unit
FTXG35EV1BW
RXG35E2V1B
FTXG35EV1BS
RXG35E2V1B
Hz-volts
50 - 220
50 - 230
50 - 240
50 - 220
50 - 230
50 - 240
3
Power supply
Voltage range
Comp.
MCA
MFA
RHz
Max. 50Hz 264V
Min. 50Hz 198V
12
15
80
Max. 50Hz 264V
Min. 50Hz 198V
12
15
80
OFM
RLA
4.9
4.7
4.5
4.9
4.7
4.5
W
35
35
IFM
FLA
0.23
0.22
0.21
0.23
0.22
0.21
W
FLA
0.52
0.50
0.48
0.52
0.50
0.48
40
40
3D045221B
SYMBOLS
6
NOTES
MCA
: Min. Circuit Amps (A)
MFA
: Max. Fuse Amps (A)
RLA
: Rated Load Amps (A)
OFM
: Outdoor Fan Motor
IFM
: Indoor Fan Motor
FLA
: Full Load Amps (A)
W
: Fan Motor Rated Output (W)
RHz
: Rated operating frequency(Hz)
• Split Sky Air • Outdoor Units
1
RLA is based on the following conditions:
Indoor temperature 27°CDB/19°CWB
Outdoor temperature 35°CDB
2
Maximum allowable voltage variation between phases is 2%
3
Select wire size based on the larger value of MCA.
4
Instead of fuse, use circuit breaker
5
For more details concerning conditional connections, see
http://extranet.daikineurope.com, select ’’E-Data Books’’.
Finally, click on the document title of your choice.
• Outdoor Units • R-410A • RXG-E2V1B
4
Capacity tables
4-1
Cooling/Heating capacity tables
3
RXG + FTXG25E
Cooling
Indoor
EWB
(°C)
14.0
16.0
18.0
19.0
22.0
24.0
7.4
0.18
Outdoor temperature (°C)
EDB
(°C)
20
22
25
27
30
32
20
SHC
1.84
1.84
1.93
2.03
1.95
1.90
TC
2.50
2.68
2.79
2.85
3.02
3.14
PI
0.46
0.48
0.48
0.48
0.49
0.49
Heating
Indoor
EDB
(°C)
16.0
18.0
20.0
21.0
22.0
24.0
AFR
BF
50Hz 220-240V
60Hz 220-230V
TC
2.44
2.56
2.68
2.73
2.91
3.02
25
SHC
1.82
1.79
1.88
1.98
1.91
1.86
PI
0.52
0.52
0.53
0.53
0.53
0.54
TC
2.33
2.44
2.56
2.62
2.79
2.90
50Hz 220-240V
60Hz 220-230V
-10
TC
2.27
2.22
2.17
2.15
2.12
2.08
-5
PI
0.70
0.71
0.72
0.72
0.72
0.73
TC
2.65
2.60
2.56
2.53
2.51
2.46
PI
0.74
0.74
0.75
0.75
0.76
0.77
30
SHC
1.76
1.73
1.82
1.93
1.87
1.82
PI
0.57
0.57
0.57
0.57
0.58
0.58
AFR
Outdoor temperature (°CWB)
0
TC
PI
3.03
0.77
2.99
0.78
2.94
0.78
2.92
0.79
2.89
0.79
2.85
0.80
32
SHC
1.74
1.71
1.80
1.91
1.85
1.81
TC
2.28
2.40
2.51
2.57
2.74
2.86
PI
0.59
0.59
0.59
0.59
0.60
0.60
TC
2.21
2.33
2.44
2.50
2.67
2.79
35
SHC
1.70
1.68
1.77
1.88
1.82
1.78
PI
0.61
0.62
0.62
0.62
0.62
0.63
TC
2.10
2.21
2.33
2.38
2.56
2.67
40
SHC
1.64
1.63
1.72
1.83
1.78
1.74
PI
0.66
0.66
0.66
0.67
0.67
0.67
4
7.7
6
10
TC
3.49
3.45
3.40
3.38
3.35
3.31
PI
0.81
0.82
0.83
0.83
0.83
0.84
TC
3.80
3.75
3.71
3.68
3.66
3.61
PI
0.84
0.84
0.85
0.86
0.86
0.87
3D045218B
SYMBOLS
AFR
: Air flow rate
BF
: Bypass factor
EWB
: Entering wet bulb temp.
NOTES
(m3/min)
1
(°CWB)
2
3
TC, PI and SHC must be calculated by interpolation using the figures
in the above tables. (Figures out of the tables should not be used for
calculation.)
4
SHC is based on each EWB and EDB
SHC1 for any indoor dry-bulb temperatures (EDB1) shall be
calculated by the following formula.
SHC*: Correction value of SHC matched with the differential of EDB
and EDB1.
SHC*=0.02 X AFR(m3/min.) X (1-BF) X (EDB1-EDB)
The calculation value of SHC1 = SHC + SHC*
5
Capacities are based on following conditions:
Corresponding refrigerant piping length:
Level difference:
EDB
: Entering dry bulb temp.
(°CDB)
TC
: Total cooling capacity
(kW)
SHC
: Sensible heating capacity
(kW)
PI
: Power input
(kW)
6
• Split Sky Air • Outdoor Units
Ratings shown are net capacities which include a deduction for
indoor fan motor heat
shows nominal (rated) capacities and power input.
7.5 m
0m
Air flow rate (AFR) and Bypass factor (BF) are taburated above.
7
• Outdoor Units • R-410A • RXG-E2V1B
4
Capacity tables
4-1
Cooling/Heating capacity tables
RXG + FTXG35E
Cooling
Indoor
EWB
(°C)
14.0
16.0
18.0
19.0
22.0
24.0
4
7.9
0.18
Outdoor temperature (°C)
EDB
(°C)
20
22
25
27
30
32
20
SHC
1.97
2.23
2.49
2.60
2.49
2.42
TC
2.67
3.39
3.91
3.99
4.23
4.39
PI
0.56
0.72
0.82
0.82
0.83
0.84
Heating
Indoor
EDB
(°C)
16.0
18.0
20.0
21.0
22.0
24.0
AFR
BF
50Hz 220-240V
60Hz 220-230V
TC
2.67
3.39
3.75
3.83
4.07
4.23
25
SHC
1.97
2.23
2.41
2.52
2.42
2.35
PI
0.65
0.83
0.90
0.90
0.91
0.91
TC
2.67
3.39
3.58
3.66
3.90
4.07
50Hz 220-240V
60Hz 220-230V
-10
TC
2.80
2.74
2.68
2.65
2.62
2.57
-5
PI
0.96
0.98
0.99
0.99
1.00
1.01
TC
3.27
3.21
3.16
3.13
3.10
3.04
PI
1.01
1.02
1.03
1.04
1.04
1.05
30
SHC
1.97
2.23
2.34
2.44
2.36
2.29
PI
0.74
0.96
0.98
0.98
0.99
0.99
AFR
Outdoor temperature (°CWB)
0
TC
PI
3.75
1.06
3.69
1.07
3.63
1.08
3.60
1.08
3.57
1.09
3.51
1.10
32
SHC
1.97
2.21
2.31
2.41
2.33
2.27
TC
2.67
3.36
3.52
3.60
3.84
4.00
PI
0.79
1.01
1.01
1.01
1.02
1.02
TC
2.67
3.26
3.42
3.50
3.74
3.90
35
SHC
1.97
2.17
2.26
2.37
2.29
2.23
PI
0.86
1.05
1.06
1.06
1.07
1.07
TC
2.67
3.10
3.26
3.34
3.58
3.74
40
SHC
1.97
2.08
2.18
2.30
2.23
2.17
PI
0.99
1.13
1.14
1.14
1.15
1.15
7.9
6
10
TC
4.32
4.26
4.20
4.17
4.14
4.02
PI
1.11
1.12
1.14
1.14
1.15
1.14
TC
4.70
4.64
4.57
4.43
4.30
4.02
PI
1.15
1.16
1.17
1.14
1.12
1.06
3D034219B
SYMBOLS
AFR
: Air flow rate
BF
: Bypass factor
EWB
: Entering wet bulb temp.
NOTES
(m3/min)
1
(°CWB)
2
(°CDB)
3
TC, PI and SHC must be calculated by interpolation using the figures
in the above tables. (Figures out of the tables should not be used for
calculation.)
4
SHC is based on each EWB and EDB
SHC*: Correction value of SHC matched with the differential of EDB
and EDB1.
SHC*=0.02 X AFR(m3/min.) X (1-BF) X (EDB1-EDB)
The calculation value of SHC1 = SHC + SHC*
5
Capacities are based on following conditions:
Corresponding refrigerant piping length:
Level difference:
EDB
: Entering dry bulb temp.
TC
: Total cooling capacity
(kW)
SHC
: Sensible heating capacity
(kW)
PI
: Power input
(kW)
6
8
• Split Sky Air • Outdoor Units
Ratings shown are net capacities which include a deduction for
indoor fan motor heat
shows nominal (rated) capacities and power input.
7.5 m
0m
Air flow rate (AFR) and Bypass factor (BF) are taburated above.
• Outdoor Units • R-410A • RXG-E2V1B
5
Dimensional drawing & centre of gravity
5-1
Dimensional drawing
unit (mm)
RXG25-35E
Minimum space for air passage
Drain outlet
(I.D. J 15.9 hose for connection)
Wall height on air outlet side = less
than 1200
4 x holes for anchor bolts (M8 or M10)
5
Handle
Brand name label
Terminal strip with earth
terminal
Name plate
Outdoor air thermistor
Liquid stop valve
(J6.4 CuT)
Wiring inlet
Service port
In case of removing
stop valve cover
Gas stop valve
(J9.5 CuT)
3D041800F
• Split Sky Air • Outdoor Units
9
• Outdoor Units • R-410A • RXG-E2V1B
5
Dimensional drawing & centre of gravity
5-2
Centre of gravity
RXG25-35E
5
4D044107F
10
• Split Sky Air • Outdoor Units
• Outdoor Units • R-410A • RXG-E2V1B
6
Piping diagram
RXG25-35E
3
Outdoor unit
Heat exchanger
Outdoor temperature thermistor
6
Heat exchanger thermistor
Motor operated valve
Muffler with
filter
Filter
Muffler with
filter
Propeller fan
Four way valve
on : heating
Field piping
Liquid stop valve
Muffler
Discharge pipe
thermistor
Field piping
Compressor
Accumulator
Muffler
Gas stop valve
Refrigerant flow
Cooling
Heating
3D045139D
• Split Sky Air • Outdoor Units
11
• Outdoor Units • R-410A • RXG-E2V1B
7
Wiring diagram
7-1
Wiring diagram
RXG25-35E
g
Field wiring
Indoor
7
Note
1. Refer to the name plate for the power requirements.
R
C74, C75
C94, C95, C100
DB1, DB2
FU1, FU2, FU3
LC11
LPM1
L
L1
L1R
M1C
M1F
MRCW,
MRM10, MRM20
N
PCB1, PCB2
Q1L
12
Outdoor
In case of cooling
only type
: Protective earth
: Capacitor
: Diode bridge
: Fuse
: Solid state relay
: Intelligent power module
: Live
: Coil
: Reactor
: Compressor motor
: Fan motor
: Magnetic relay
: Neutral
: Printed circuit board
: Overload protector
R1T, R2T, R3T, S10
S11, S20, S30, S40
S70, S80, S90, S91
HC3, HC4, HL3, HN3
SA1
Z1C, Z2C
X1M
V1, V2, V3
Y1E
Y1R
In case of heat pump
type
(outdoor)
(discharge)
(Condenser)
: Thermistor
: Connector
: Surge arrester
: Ferrite core
: Terminal strip
: Varistor
: Electronic expansion valve coil
: Reversing solenoide valve coil
• Split Sky Air • Outdoor Units
3D042576H
• Outdoor Units • R-410A • RXG-E2V1B
8-1
Sound pressure spectrum
3
RXG25E (Cooling)
RXG25E (Heating)
Octave band sound pressure level
Sound data
Octave band sound pressure level
8
approximate
threshold hearing for
continuous noise
approximate
threshold hearing for
continuous noise
3D044103D
Octave band center frequency (Hz)
NOTES
1
2
3D044103D
1
2
3
50/60Hz, 220-240V
RXG35E (Cooling)
RXG35E (Heating)
Octave band sound pressure level
Octave band sound pressure level
approximate
threshold hearing for
continuous noise
approximate
threshold hearing for
continuous noise
Octave band center frequency (Hz)
NOTES
1
2
3
Location of microphone
Measure in anechoic room
Operation noise differs with operation and
ambient conditions.
The operation noise measuring method is in
accordance with JISC9612
Legend
Legend
50/60Hz, 220-240V
3D044104D
Octave band center frequency (Hz)
NOTES
Location of microphone
Measure in anechoic room
Operation noise differs with operation and
ambient conditions.
The operation noise measuring method is in
accordance with JISC9612
3
8
3D044104D
NOTES
Location of microphone
Measure in anechoic room
Operation noise differs with operation and
ambient conditions.
The operation noise measuring method is in
accordance with JISC9612
Octave band center frequency (Hz)
1
2
3
Location of microphone
Measure in anechoic room
Operation noise differs with operation and
ambient conditions.
The operation noise measuring method is in
accordance with JISC9612
Legend
Legend
50/60Hz, 220-240V
50/60Hz, 220-240V
• Split Sky Air • Outdoor Units
13
• Outdoor Units • R-410A • RXG-E2V1B
9
Operation range
RXG25-35E
Cooling
Heating
Indoor temp. (°CWB)
Notes:
The graphs are based on the following conditions:
+ Equivalent piping length
7.5 m
+ Level difference
0m
+ Air flow rate
high
14
• Split Sky Air • Outdoor Units
Continuous operation
Outdoor temp. (°CWB)
Pull-down period
Continuous operation
Outdoor temp. (°CDB)
9
Indoor temp. (°CDB)
3D045140C
Split - Sky Air
ISO14001 assures an effective environmental
management system in order to help protect
human•health•and the environment from the potential
impact of our activities, products and services and to
assist in maintaining and improving the quality of
the•environment.
Daikin units comply with the European
regulations that guarantee the safety of
the product.
Daikin Europe N.V. is approved by LRQA for its Quality
Management System in accordance with the ISO9001
standard. ISO9001 pertains to quality assurance regarding
design, development, manufacturing as well as to services
related to the product.
Daikin Europe N.V. is participating in the
EUROVENT Certification Programme.
Products are as listed in the EUROVENT
Directory of Certified Products.
EEDE06-1/3 • 05/2006
Prepared in Belgium by Lannoo
The present publication is drawn up by way of
information only and does not constitute an offer
binding upon Daikin Europe N.V.. Daikin Europe N.V.
has compiled the content of this publication to the
best of its knowledge. No express or implied warranty
is given for the completeness, accuracy, reliability or
fitness for particular purpose of its content and the
products and services presented therein. Specifications
are subject to change without prior notice. Daikin
Europe N.V. explicitly rejects any liability for any direct
or indirect damage, In the broadest sense, arising from
or related to the use and/or interpretation of this
publication. All content is copyrighted by Daikin
Europe N.V..
Zandvoordestraat 300
B-8400 Ostend - Belgium
www.daikineurope.com
ÉEEDE06-1/3ÇËÍ