367AAN
Low---Boy Oil Furnace
Input Capacities: 70,000 thru 154,000 BTUH
Series E
Product Data
367AAN FEATURES/BENEFITS
Beckett Oil Burner and UTEC Controls
S
S
High quality Beckett oil burner with “clean--cut” pump allows
safe and efficient combustion of oil.
UTEC ignition control and fan timer board provide reliable
operation and easy connection of thermostat and accessory
wiring.
Casing
S
S
Made of 18--gauge painted steel for years of durability.
Cabinet features an insulated enclosure for the burner and
controls.
Insulation and Soundproofing
S
Unique sound trap along with insulated walls efficiently
captures most combustion and vibration noise to make this unit
one of the quietest on the market.
Combustion Products Venting
A06624
THE LATEST IN OIL FURNACE
TECHNOLOGY
The model 367AAN combines high efficiency and quiet operation
with oil heating technology. The 367AAN is available in 2 sizes.
Each size can be fired at 3 different rates by a simple nozzle and
pump pressure change. Unit 367AAN105 covers input ranges from
70,000 to 105,000 BTUH. Unit 367AAN120 covers input ranges
from 119,000 to 154,000 BTUH. The furnace design is a low--boy
style for upflow applications, where overhead space is limited.
The components of the 367AAN are the finest in the industry. The
unit uses a Beckett oil burner with a UTEC ignition controller,
“clean--cut” oil pump and fan cycler timer.
The 367AAN is a standard part of a quality--built home. This high
efficiency furnace will provide years of quality service to home
builders and homeowners alike.
As with other Bryant furnaces, this model is designed to work as
part of a total home comfort system which includes elements for
cooling, air cleaning, humidification, ventilation, and zoning.
This unit is not approved for use in mobile home installations.
S
S
S
Rear flue outlet.
Unit may be vented using Type L vent material and a
factory--built metal or masonry chimney.
Unit may also be sidewall vented with an approved power
venter.
Adjustable Blower Speed
S
4--speed blower for precise airflow selection of heating or
cooling operation.
Constant Low--Speed Blower Switch
S
S
S
Allows continual low--speed air circulation through the home
to maximize comfort while maintaining efficiency.
Air is constantly filtered and stagnant air is avoided.
This option can be controlled by the homeowner.
Combustion Chamber/Heat Exchanger
S
S
S
Composed mainly of stainless and aluminized steel, the unique
combination combustion chamber/heat exchanger resists
corrosion, overheating, and deterioration.
Heat transfer properties make it highly efficient.
All seams are tightly welded for leak--free operation.
Certifications
S
S
367AAN unit is CSA certified.
The efficiency is AHRI efficiency rating certified.
UNUSED
3
1
2
3
4
5
X
H
U
M
LEADS
N
S
2
E
A
C
C
O
N
T
C
O
O
L
H
E
A
T
6
7
C
367AAN
W
R
Y
COMBUSTION CHAMBER/
HEAT EXCHANGER
ON
1 2
G
C
A96369
A03172
A96370
CONTROL CENTER
OIL BURNER
Always Ask For
C
US
Use of the AHRI Certified TM Mark indicates a
manufacturer’s participation in the program. For
verification of certification for individual products,
go to www.ahridirectory.org.
2
;;;
;;;
;;;;
;;
;;
;;
4
3
8
;;
;;
;;
9
10
11
12
X
C
HUM
5
4
3
2
N
1
7
6
3
COOL
UNUSED
S
LEADS
HEAT
CONT
2
EAC
1
2
1
7
ON
2
6
C
Y
R
W
G
367AAN
5
13
14
A96281
1. Heavy--duty blower circulates air across the heat exchanger to transfer heat into the home.
2. Access door to air filters and blower.
3. Air filters
4. Unique silencer system controls combustion noise.
5. Return--air plenum
6. Stainless steel combustion chamber
7. Heat exchanger designed and shaped to efficiently transfer heat from furnace into the home.
8. Supply--air plenum
9. Fully insulated internal walls to minimize heat loss.
10. High limit control to prevent overtemperature.
11. Manual switch to allow user control of constant low--speed blower operation.
12. Adjustable electronic fan timer control (inside) has low voltage electrical terminal strip for easy connection of thermostat, cooling
control, electronic air cleaner, and humidifier.
13. Aesthetic removable cover. Hides and protects burner and controls.
14. High--performance oil burner
3
PHYSICAL DATA
21 1/4″
20"
20"
20"
VENT
CONN
10"
3"
E
367AAN
D
B
C
A
A98009
DIMENSIONS (IN.)
UNIT
SIZE
Width
036105
060120
21--- 1/4
21--- 1/4
UNIT DIMENSIONS
Depth
A
53--- 3/4
60--- 3/16
Height
B
31--- 1/2
34--- 3/4
FLUE HEIGHT
RETURN
OPENING
SUPPLY
OPENING
C
26--- 1/2
28--- 3/8
D
20
22
E
20
24
4
VENT
CONNECTION
5
6
UNIT SIZE
INPUT (BTUH)*
HEATING CAPACITY
NOZZLE
PRESSURE (PSIG)
FIRING RATE (GPH)
AFUE%
OIL PUMP STAGES
HEATING TEMP RISE _F
COOLING CFM @ 0.5--- IN. WC STATIC PRESSURE
HEATING CFM @ 0.2--- IN. WC STATIC PRESSURE
RECOMMENDED HEATING BLOWER SPEED
BURNER MODEL (3450 RPM){
70,000
57,000
0.50 --- 70W
100
0.50
80.5
1
55--- 85
1250
840
Med --- Low
BECKETT
AFG--- F3
036105
91,000
74,000
0.55 --- 70B
140
0.65
80.5
1
55--- 85
1250
1130
Med --- High
BECKETT
AFG--- F3
105,000
85,000
0.65 --- 70B
130
0.75
80.5
1
55--- 85
1250
1425
High
BECKETT
AFG--- F3
119,000
97,000
0.75 --- 70B
130
0.85
80.0
1
55--- 85
1865
1555
Med --- Low
BECKETT
AFG--- F3
060120
140,000
115,000
0.85 --- 70B
140
1.00
80.0
1
55--- 85
1865
1890
Med --- Low
BECKETT
AFG--- F3
154,000
126,000
0.85 --- 70B
170
1.10
80.0
1
55--- 85
1865
2080
High
BECKETT
AFG--- F6
* Capacity and AFUE in accordance with U.S. Government DOE test procedures.
{ Beckett AFG---F6 requires field supplied and replacement burner firing head.
--- Shaded cells are as Factory Shipped.
UNIT SIZE
DIRECT--- DRIVE MOTOR Hp (PSC)
036105
060120
1/3
3/4
MOTOR FULL LOAD AMPS
6.2
9.5
RPM (Nominal) --- SPEEDS
1075--- 4
1075--- 4
10 x 8
12 x 10
BLOWER WHEEL DIAMETER X WIDTH (In.)
SHIPPING WEIGHT (LB)
FILTER SIZE (In.) --- (Disposable)
235
260
(2) 12 x 20 x 1
(2) 16 x 20 x 1
AIR DELIVERY - CFM (WITH FILTERS)
UNIT SIZE
BLOWER
MOTOR HP
036105
060120
1/3 PSC
3/4 PSC
SPEED
EXTERNAL STATIC PRESSURE (in wc)
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
High
1425
1350
1305
1250
1170
1030
925
805
Med --- High
1130
1045
1000
950
885
820
745
670
Med --- Low
840
810
770
740
685
635
580
500
Low
725
730
740
745
730
715
690
665
High
2080
2040
1965
1865
1700
1575
1475
1335
Med --- High
1890
1860
1770
1675
1550
1450
1330
1215
Med --- Low
1555
1475
1395
1320
1210
1135
1050
940
Low
1220
1165
1080
1000
925
855
780
655
ELECTRICAL DATA
UNIT SIZE
036105
060120
115 --- 60 --- 1
115 --- 60 --- 1
104 --- 132
104 --- 132
12.2
15.7
MINIMUM WIRE SIZE (AWG)
14
12
MAXIMUM WIRE LENGTH (Ft){
26
26
MAXIMUM FUSE SIZE OR CKT BKR (Amps)}
15
20
40va
40va
Heating
40va
40va
Cooling
30va
30va
Standard
Standard
UNIT VOLTS--- HERTZ --- PHASE
OPERATING VOLTAGE RANGE (Min--- Max)*
MAXIMUM UNIT AMPS
TRANSFORMER (24v)
EXTERNAL CONTROL POWER AVAILABLE
AIR CONDITIONING RELAY
* Permissible limits of the voltage range at which the unit will operate satisfactorily.
{ Length is a measured one way along wire path between unit and service panel for maximum 2% voltage drop.
} Time ---delay fuse type is recommended.
5
367AAN
SPECIFICATIONS
CLEARANCE TO COMBUSTIBLES
UNIT APPLICATION
SIDES
FLUE PIPE
1
Supply Plenum and Warm--- Air Duct Within 6 Ft of Furnace
1
Service Clearance
19
BACK
TOP
LOW---BOY
Furnace
Furnace Casing or Plenum
2
Horizontal Warm--- Air Duct Within 6 Ft of Furnace
2
Horizontally or Below Pipe
4
Vertically Above Pipe
9
FRONT
8
BOTTOM*
0
367AAN
*Floor may be combustible.
NOTE: Adequate service clearance should be provided over and above these dimensions as required.
6
ACCESSORIES
Available in programmable and
non ---programmable models,
Bryant thermostats maintain a
constant, comfortable temperature level in the home.
For the ultimate in home comfort, Bryant’s 2, 4, and 8 ---zone
systems allow temperature control of individual “zones” of the
home. This is accomplished
through a series of electronic
dampers and remote room sensors. The 4 ---zone system is
shown.
A94336
ENERGY/HEAT
RECOVERY
VENTILATOR
Bryant’s energy or heat recovery ventilators exhaust
stale indoor air and provide
fresh outdoor air to the home
while minimizing heat loss
and humidity level. Especially useful for today’s tighter
constructed houses.
Energy recovery ventilator is
shown.
A07043
ELECTRONIC OR
MECHANICAL AIR
CLEANER
Cleans the air of smoke, dirt,
and many pollens commonly
found. Saves decorating and
cleaning expenses by keeping
carpets, furniture, and drapes
cleaner.
Electronic air cleaner is
shown.
A91365
HUMIDIFIER
By adding moisture to winter --dry air, Bryant humidifier can
often improve comfort and
keeps woodwork, wallpaper,
and paint in better condition.
Moisturizing household air
also helps to retain normal
body heat and provides comfort at lower temperatures.
KLABV0201DET
FURNACE ACCESSORIES
Blocked Vent Shutoff Kit
T1--- PAC01
T1--- PHP01
T2--- PAC01
T2--- PHP01
PROGRAMMABLE THERMOSTAT SELECTION
Thermostat, Manual Changeover, 5--- 2 Day Programmable, °F/°C, 1--- Stage Heat/1--- Stage Cool
Thermostat, Manual Changeover, 5--- 2 Day Programmable, °F/°C, 2--- Stage Heat/1--- Stage Cool
Thermostat, Auto Changeover, 5--- 2 Day Programmable, °F/°C, 1--- Stage Heat/1--- Stage Cool
Thermostat, Auto Changeover, 5--- 2 Day Programmable, °F/°C, 3--- Stage Heat/2--- Stage Cool
T1--- NAC01
T1--- NHP01
T2--- NAC01
T2--- NHP01
NON--- PROGRAMMABLE THERMOSTAT SELECTION
Thermostat, Manual Changeover, Non--- Programmable, °F/°C, 1--- Stage Heat/1--- Stage Cool
Thermostat, Manual Changeover, Non--- Programmable, °F/°C, 2--- Stage Heat/1--- Stage Cool
Thermostat, Auto Changeover, Non--- Programmable, °F/°C, 1--- Stage Heat/1--- Stage Cool
Thermostat, Auto Changeover, Non--- Programmable, °F/°C, 3--- Stage Heat/2--- Stage Cool
ZONEBB2KIT01--- B
ZONEBB4KIT01--- B
ZONEBB8KIT01--- B
ZONING CONTROL SELECTION
Comfort Zone II--- B --- 2 Zone Kit/Temperature and Humidity Control
Comfort Zone II--- B --- 4 Zone Kit/Temperature and Humidity Control
Comfort Zone II--- B --- 8 Zone Kit/Temperature and Humidity Control
HUMBBSBP2312
HUMBASBP2312
HUMBBLBP2317
HUMBALBP2317
HUMBBLFP1318
HUMBALFP1318
HRVBBSHA1100
HRVBBSVA1100
HRVBBLHA1150
HRVBBLHA1250
HRVBBSVU1150
HRVBBSVU1200
HRVBBLVU1150
HRVBBLVU1200
HRVBBLVU1330
HEALTHY HOME SOLUTIONS
Humidifier --- 12 g./day, 24V Standard, Small Bypass
Humidifier --- 12 g./day, 24V Automatic, Small Bypass
Humidifier --- 17 g./day, 24V Standard, Large Bypass
Humidifier --- 17 g./day, 24V Automatic, Large Bypass
Humidifier --- 18 g./day, 24V Standard, Fan Powered
Humidifier --- 18 g./day, 24V Automatic, Fan Powered
Heat Recovery Ventilator --- Small Horizontal Unit, 100 CFM
Heat Recovery Ventilator --- Small Vertical Unit, 100 CFM
Heat Recovery Ventilator --- Large Horizontal Unit, 150 CFM
Heat Recovery Ventilator --- Large Horizontal Unit, 250 CFM
Heat Recovery Ventilator --- Small Vertical Unit, 150 CFM
Heat Recovery Ventilator --- Small Vertical Unit, 200 CFM
Heat Recovery Ventilator --- Large Vertical Unit, 150 CFM
Heat Recovery Ventilator --- Large Vertical Unit, 200 CFM
Heat Recovery Ventilator --- Large Vertical Unit, 330 CFM
7
367AAN
A07042
CONTROLS:
THERMOSTATS
AND ZONING
ACCESSORIES (CONT)
ERVBBLHU1150
ERVBBLHU1200
EZXCABBB1016
EZXCABBB1020
Energy Recovery Ventilator --- Large Horizontal Unit, 150 CFM
Energy Recovery Ventilator --- Large Horizontal Unit, 200 CFM
Media Filter Cabinet --- 1600 CFM (Replacement Filter: EXPXXFIL0016)
Media Filter Cabinet --- 2000 CFM (Replacement Filter: EXPXXFIL0020)
367AAN
TYPICAL INSTALLATION
AIR CONDITIONER
OR HEAT PUMP
RETURN-AIR
DUCT
SUPPLY-AIR DUCT
CHIMNEY
OIL TANK
A/C COIL
LOW-BOY OIL
FURNACE
FLUE
PIPE
AIR FLOW
A98010
E2010 Bryant Heating & Cooling Systems 7310 W. Morris St. Indianapolis, IN 46231
Printed in U.S.A.
Edition Date: 10/10
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
8
Catalog No: PDS367A.70.3
Replaces: PDS367A.70.2