PLANNING
GUIDE
Opening Dimensions
◊
To avoid tipping during use, the solid soffit must be within 1”
(2.5 cm) maximum above the refrigerator. If the solid soffit
is higher than 1” (2.5 cm) or one is not available, then the
refrigerator must be braced.
If the anti-tip boards are needed, they must be attached to the
rear wall studs 80” to 90” (203 cm to 229 cm) above the floor.
See installation instructions for more information.
NOTE: A clearance of ¹⁄2” (1.3 cm) must be maintained above
the top grille in order for the top grille to be removed.
4"
(10.2 cm)
83¹/2" (212.1 cm) min.
84³/4" (215 cm) max.
to bottom of solid soffit
/2"
(1.3 cm)
1
77"
(196 cm)
◊
A grounded 3 prong electrical outlet should be placed within
4” (10.2 cm) of the right side cabinets or end panel. See
Electrical Requirements for more information.
◊
The water shutoff should be located in the base cabinet on
either side of the refrigerator or some other easily accessible
area. If the water shutoff valve is not in the cabinets, the
plumbing for the water line can come through the floor or
the back wall. See Water Supply Requirements for more
information.
A
Width
(see chart following)
24"
(60.96 cm) min.
See Page 11.15
Model Series
Cutout Width A
EF42, IF42
41½” (105.4 cm) to 41¾” (106.1 cm)
EF48, IF48
47½” (120.7 cm) to 47¾” (121.3 cm)
NOTE: Flooring under refrigerator must be at same level as the
room. Face of cabinetry must be plumb.
Web: http://www.Dacor.com
Corporate Phone: 800-793-0093
Specifications are subject to change without notice.
See installation instructions for additional details.
11.14
EF42DBSS, EF42NBSS, EF48DBSS, EF48NBSS,
IF42DBOL, IF42NBOL, IF48DBOL, IF48NBOL
Revised
04/22/08
42” and 48” Wide
Built-In Refrigerators
2/6
PLANNING
GUIDE
Electrical Requirements
Water Supply Requirements
The electrical circuit must meet all local codes and ordinances.
◊
All installations must meet local plumbing code requirements.
Recommended Grounding Method
◊
The water shutoff should be located in the base cabinet on
either side of the refrigerator or some other easily accessible
area. The right-hand side is recommended. The access hole
through the cabinet must be within ½” (12.7 mm) of the rear
wall.
A 115 Vac, 60 Hz., 15 or 20 Amp fused, grounded electrical supply
is required. It is recommended that a separate circuit serving only
your refrigerator be provided. Use an outlet that cannot be turned
off by a switch. Do not use an extension cord.
IMPORTANT: If this product is connected to a GFCI (Ground Fault
Circuit Interrupter) protected outlet, nuisance tripping of the power
supply may occur, resulting in loss of cooling. Food quality and
flavor may be affected.
NOTE: If the water shut off valve is in the back wall behind the
refrigerator, it must be at an angle so that the tube is not kinked
when the refrigerator is pushed into its final position.
Access hole within 1/2”
(12.7 mm) of floor and rear wall
Possible water
line locations
6"
(15.2 cm)
1"
(2.54 cm)
6"
(15.2 cm)
Water Pressure
A cold water supply with water pressure between 30 and 120 psi
(207 and 827 kPa) is required to operate the water dispenser and
ice maker.
Reverse Osmosis Water Supply
IMPORTANT: The pressure of the water supply coming out of
a reverse osmosis system going to the water inlet valve of the
refrigerator needs to be between 30 and 120 psi (207 and 827
kPa). If a reverse osmosis water filtration system is connected to
your cold water supply, the water pressure to the reverse osmosis
system needs to be a minimum of 40 to 60 psi (276 to 414 kPa).
Web: http://www.Dacor.com
Corporate Phone: 800-793-0093
Specifications are subject to change without notice.
See installation instructions for additional details.
11.15
EF42DBSS, EF42NBSS, EF48DBSS, EF48NBSS,
IF42DBOL, IF42NBOL, IF48DBOL, IF48NBOL
42” and 48” Wide
Built-In Refrigerators
Revised
04/22/08
Door Swing Dimension
The location must permit both doors to open to a minimum of
90°. Allow 4½” (11.4 cm) minimum space between the side of the
refrigerator and a corner wall.
3/6
NOTE: More clearance may be required if you are using overlay
panels, custom handles or extended handles on a IF series
model.
To adjust the door swing, see the installation instructions.
EF42 and IF42 Model Series
EF48 and IF48 Model Series
17¹⁄ 2 "
(44 cm)
19 ³⁄4 "
(50 cm)
429⁄16 "
(108 cm)
38"
(97 cm)
PLANNING
GUIDE
45¹⁄4 "
(115 cm)
40"
(102 cm)
23¹⁄4 "
(59 cm)
26³⁄4 "
(68 cm)
47"
(119 cm)
41"
(104 cm)
90˚
110˚
130˚
50¹⁄2 "
(128 cm)
43¹⁄2 "
(110 cm)
90˚
110˚
130˚
90˚
110˚
130˚
90˚
110˚
130˚
Door Swing 90°
Door Panels and Cabinetry Clearance IF42/IF48 Series Models
The custom door panels and adjacent cabinetry for models
series IF42 and IF48 must be designed so that there is sufficient
clearance for the doors to swing open. If the refrigerator is to be
installed close to the wall, see Door Swing 90°.
Refrigerator to
Cabinetry Clearance
Door Swing 90˚
Actual Size
Refrigerator to
Cabinetry Clearance
Refrigerator
Side Trim
Door Swing 110°
Refrigerator to
Cabinetry Clearance
1"
(2.5 cm)
/"
(1.9 cm)
1
/2"
(1.3 cm)
3 4
Refrigerator
Side Trim
90° Door
Stop Position
11/2"
(3.8 cm)
11/4"
(3.2 cm)
1"
(2.5 cm)
Cabinetry
/ " (6.35 mm)
1 4
Hinge
/ " (1.3 cm)
1 2
Cabinetry
110˚ Door
Stop Position
/ " (1.9 cm)
3 4
1" (2.5 cm)
/4" (6.35 mm)
1
Hinge
/2" (1.3 cm)
1
/4" (1.9 cm)
3
1" (2.5 cm)
1/2"
(1.3 cm)
1 /2 "
(1.3 cm)
3
/4"
(1.9 cm)
3/4"
(1.9 cm)
1"
(2.5 cm)
1"
(2.5 cm)
Door
Ove
11/4"
(3.2 cm)
Spacer Panel
When the doors are closed the refrigerator will extend beyond the face of the adjacent
cabinetry to some degree.
Web: http://www.Dacor.com
Corporate Phone: 800-793-0093
Overlay Panel
l
e
Pan
l
e
Pan
11/2"
(3.8 cm)
Backer Panel
rlay
ker
Bac
r
Doo
NOTE: For IF Series models,
rout the hinge side of the
custom door panels to a radius
that is equal to at least half the
thickness of the panel if a 130°
door swing is desired. See the
installation instructions.
11/4"
(3.2 cm)
11/2"
(3.8 cm)
Spacer Panel
Allow a minimum of 4½” (11.4 cm) of space between the side of the refrigerator and a
corner wall. More clearance may be needed if thicker custom panels or custom handles are
used. Do not overlook baseboards.
Specifications are subject to change without notice.
See installation instructions for additional details.
11.16
EF42DBSS, EF42NBSS, EF48DBSS, EF48NBSS,
IF42DBOL, IF42NBOL, IF48DBOL, IF48NBOL
42” and 48” Wide
Built-In Refrigerators
Revised
04/22/08
Custom Panels
and
Handles - IF42/IF48 Series Models
Install the panels after moving the refrigerator into
place.
The weight of the overlay panels cannot exceed:
The custom panels must have backer panels attached in order
to mount them to the refrigerator. It is most common to work with
three panels, as shown in the graphic below. A decorative overlay
panel, a ¹/8” (3.18 mm) spacer panel or spacer strips and a ¼”
(6.35 mm) backer panel.
50 lbs (23 kg) for the refrigerator door.
30 lbs (13.5 kg) for the freezer door.
10 lbs (4.5 kg) for the top grille.
To minimize panel weight, you may use 2” (5.08 cm) spacer strips
around the perimeter in place of full-sheet solid spacer panels.
The spacer strips must be set in at least 1” (2.54 cm) from the
top, bottom and sides edges of the backer panel. If you use
spacer strips, it is also recommended that you use two 2” (5.08
cm) strips horizontally centered for added support.
Spacer Panel
Spacer Panel
1/8"
(3.18 mm)
NOTE: For the grille and the door panels to be flush, the overlay
door panel should be ¼” (6.35 mm) thicker than the overlay grille
panel.
1" minimum
(2.54 cm)
5/8" to 3/4"
(15.88 to
19.05 mm)
Door/Grille Trim
Offset Dimension
Backer Panel
1/4"
4/6
IMPORTANT:
Custom overlay panels used with models IF42 and IF48 allow you
to blend the exterior of your refrigerator into the overall kitchen
décor, and to use custom handles for additional design flexibility.
Overlay Panel
PLANNING
GUIDE
1/8"
(6.35 mm)
(3.18 mm)
Top Grille
In some cases, your cabinet manufacturer may choose to work
with one panel routed for the different dimensions. Follow these
panel dimension and placement instructions to be sure that the
custom overlay panels will fit properly.
C
7 3/ 8 "
(18.73 cm)
Backer
Bottom
Offset
1" (2.54 cm)
F
81/2"
(21.59 cm)
Freezer Panel for
Dispenser Models
Freezer Panel for
Non-Dispenser Models
Refrigerator Panel for
all Models
A
A
B
23 7⁄16"
(59.53 cm)
4 ¹⁄4 "
(107.95 cm)
Handle-Side
Offset
¹⁄8 " (3.2 mm)
Handle-Side
Offset
¹⁄8 " (3.2 mm)
D
11 ¹⁄8 "
(282.58 cm)
70¹⁄2 "
(179.07 cm)
12 "
(30.48 cm)
47 ³⁄16 "
(119.86 cm)
70¹⁄2 "
(179.07 cm)
71¹⁄16 "
(180.50 cm)
71¹⁄16 "
(180.50 cm)
D
D
E
35”
(88.90 cm)
34 ³⁄8 "
(87.3 cm)
Backer Bottom Offset
¹⁄8 " (3.2 mm)
Backer Bottom Offset
¹⁄8 " (3.2 mm)
Backer Bottom Offset
¹⁄8 " (3.2 mm)
Decorative Overlay Panels
Model
Series
A
IF42
17¹⁄8” (43.50 cm)
IF48
19
5⁄8”
(49.85 cm)
B
Backer Panels
C
23¹⁄8” (58.74 cm) 40½” (102.87 cm)
265⁄8”
(67.63 cm) 46½” (118.11 cm)
Web: http://www.Dacor.com
Corporate Phone: 800-793-0093
Model
Series
D
E
F
IF42
167⁄8” (42.86 cm)
227⁄8” (58.10 cm)
40½” (102.87cm)
IF48
3
19 ⁄8” (49.21 cm)
3
26 ⁄8” (66.99 cm)
46½” (118.11 cm)
Specifications are subject to change without notice.
See installation instructions for additional details.
11.17
EF42DBSS, EF42NBSS, EF48DBSS, EF48NBSS,
IF42DBOL, IF42NBOL, IF48DBOL, IF48NBOL
42” and 48” Wide
Built-In Refrigerators
Revised
04/22/08
5/6
PLANNING
GUIDE
Custom Side Panels - IF42/IF48
Inset Installation Dimensions
Custom side panels may be needed when not enough space is
available to have cabinets on both sides of the refrigerator or
when the refrigerator is placed at the end of a cabinet run. You
may choose an Inset or Recessed Inset panel installation for
models IF42 and IF48.
1. Measure the distance from point A (as shown) to the back wall.
Add ¹⁄32” (0.8 mm) to this measurement to allow the side panel
to fit into the trim.
2. If the panel is more than ³⁄8” (9.5 mm) thick, rout the front edge
to allow the side panel to fit into the trim.
Refrigerator and Side Trim Dimensions
The width and height of a side panel are determined by the type
of installation you are planning.
NOTES:
◊
The dimensions shown are actual product dimensions and
may not reflect the needed installation dimensions.
◊
The side panel should be a minimum of ½” (1.27 cm) thick to
avoid warping.
◊
If the opening depth is 25” (63.5 cm) or more, you may want
to install a support board on rear wall.
Back wall
A
Refrigerator
Overlay
Recessed Inset Installation Dimensions
1. Measure the distance from point A (as shown) to back wall.
⁄2"
(59.69 cm)
23 1
2. Route the front edge of the support board or attach a ³⁄8” (9.5
mm) board to hold the panel in the cabinet side trim.
Back wall
Side Trim
A
³⁄8 "
³⁄16 "
(4.5 mm)
(9.7 mm)
¹⁄16 "
(1.5 mm)
¹⁄8 "
(3.2 mm)
Web: http://www.Dacor.com
Corporate Phone: 800-793-0093
Specifications are subject to change without notice.
See installation instructions for additional details.
11.18
EF42DBSS, EF42NBSS, EF48DBSS, EF48NBSS,
IF42DBOL, IF42NBOL, IF48DBOL, IF48NBOL
Revised
04/22/08
42” and 48” Wide
Built-In Refrigerators
6/6
PLANNING
GUIDE
Custom Side Panels - EF42/EF48
Inset Installation Dimensions
Custom side panels may be needed when not enough space is
available to have cabinets on both sides of the refrigerator or
when the refrigerator is placed at the end of a cabinet run. You
may choose an inset, flush or recessed inset panel installation for
models EF42 and EF48.
1. Measure the distance from point A (as shown) to the back
wall. Add 7⁄32” (5.6 mm) to this measurement to allow the side
panel to fit into the trim.
2. If the panel is more than ¼” (6.35 mm) thick, route the front
edge to allow the side panel to fit into the trim.
Refrigerator and Side Trim Dimensions
The width and height of a side panel are determined by the type
of installation you are planning.
Back wall
NOTES:
◊
The dimensions shown are actual product dimensions and
may not reflect the needed installation dimensions.
◊
The side panel should be a minimum of ½” (1.27 cm) thick to
avoid warping.
◊
If the opening depth is 25” (63.5 cm) or more, you may want
to install a support board on the rear wall.
A
Refrigerator
Flush Installation Dimensions
24¹⁄8 "
(61.3 cm)
1. Measure the distance from point A (as shown) to the back
wall.
23¹¹⁄16"
(60.3 cm)
2. Attach the support board with a screw or adhesive that is
compatible with aluminum and wood.
23½ "
(59.7 cm)
Back wall
Side Trim
¼"
(6.35 mm)
¹¹⁄64"
(4.5 mm)
A
Recessed Inset Installation Dimensions
³⁄16"
(4.7 mm)
1. Measure the distance from point A (as shown) to the back
wall.
⁄32 "
2. Route the front edge of the support board or attach a ¼”
(6.35 mm) board to hold the panel in the cabinet side trim.
7
(5.5 mm)
Back wall
¹³⁄32" (10 mm)
Web: http://www.Dacor.com
Corporate Phone: 800-793-0093
5
⁄8 "
(15.7 mm)
A
Specifications are subject to change without notice.
See installation instructions for additional details.