9XTend-PKG-R™ RS-232/485 RF Modem

9XTend-PKG-R RF Modem

Interfacing Protocol

Modem Operation

Modem Configuration

RF Communication Modes

Appendices

Product Manual v1.2.4

For MaxStream part numbers: XT09-PK…-R…

1 Watt Transmit Power, -110 dBm Receiver Sensitivity, 256-bit AES Encryption

355 south, 520 west, suite 180

Lindon, UT 84042

Phone: (801) 765-9885

Fax: (801) 765-9895

9XTend‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v1.2.4 

© 2005 MaxStream, Inc. All rights reserved

No part of the contents of this manual may be transmitted or reproduced  in any form or by any means without the written permission of 

MaxStream, Inc.  

XTend™ and 9XTend‐PKG‐R™ are registered trademarks of   

MaxStream, Inc. 

AES Encryption Source Code 

     

© 2005 Dr. Brian Gladman, Worcester, UK. All rights reserved. 

 

Conditions:                            

‐ Distributions of AES source code include the above copyright notice,  this list of conditions and disclaimer. 

             

‐ Distributions in binary form include the above copyright notice, this  list of conditions and disclaimer in the documentation and/or other  associated materials. 

‐ The copyright holderʹs name is not used to endorse products built  using this software without specific written permission. 

Alternatively, provided that this notice is retained in full, this product  may be distributed under the terms of the GNU General Public License 

(GPL), in which case the provisions of the GPL apply INSTEAD OF  those given above. 

Disclaimer ‐ This AES software is provided ʹas isʹ with no explicit or  implied warranties in respect of its properties, including, but not  limited to, correctness and/or fitness for purpose. 

 

Technical Support:

Phone: (801) 765-9885

Live Chat: www.maxstream.net

E-Mail: [email protected]

   © 2005 MaxStream, Inc. Confidential and Proprietary  ii 

9XTend‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v1.2.4 

Contents 

1. 9XTend-PKG-R™ RF Modem 4

1.1. Features Overview 4

1.1.1. Worldwide Acceptance 4

1.2. Product Overview 5

1.2.1. Specifications 5

1.3. XTend-PKG-R Interface 6

2. Interfacing Protocol 7

2.1. RS-232 Operation 7

2.1.1. DIP Switch Settings & Pin Signals 7

2.1.2. Wiring Diagrams 8

2.2. RS-485 (2-wire) Operation 9

2.2.1. DIP Switch Settings & Pin Signals 9

2.2.2. Wiring Diagram 9

2.3. RS-485 (4-wire) & RS-422 Operation 10

2.3.1. DIP Switch Settings & Pin Signals 10

2.3.2. Wiring Diagrams 10

2.3.3. RS-485/422 Connection Guidelines 11

3. Modem Operation 12

3.1. Serial Communications 12

3.1.1. RS-232 and RS-485/422 Data Flow 12

3.1.2. Host and RF Modem Settings 12

3.1.3. Flow Control 13

3.2. Modes of Operation 14

3.2.1. Idle Mode 14

3.2.2. Transmit Mode 14

3.2.3. Receive Mode 16

3.2.4. Sleep Mode 17

3.2.5. Shutdown 17

3.2.6. Command Mode 18

4. Modem Configuration 20

4.1. Automatic DIP Switch Configurations 20

4.2. Programming Examples 21

4.2.1. AT Commands (Using X-CTU Software) 21

4.2.2. Binary Commands 22

4.3. Command Reference 23

4.4. Command Descriptions 24

5. RF Communication Modes 41

5.1. Addressing Options 41

5.2. Streaming Mode 42

5.2.1. Connection Sequence 42

5.3. Acknowledged Mode 43

5.3.1. Connection Sequence 43

5.4. Multi-Transmit Mode 45

5.4.1. Connection Sequence 45

Appendix A: Agency Certifications 46

FCC Certification 46

Labeling Requirements 46

FCC Notices 46

FCC-Approved Antennas (900 MHz) 48

IC (Industry Canada) Certification 50

Appendix B: Development Guide 51

RS-232 Accessories Kit Contents 51

Adapters 52

Antennas 53

Appendix C: Additional Information 54

1 Year Warranty 54

Ordering Information 54

Contact MaxStream 55

   © 2005 MaxStream, Inc. Confidential and Proprietary  iii 

9XTend‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v1.2.4 

1. 9XTend‐PKG‐R™ RF Modem 

The 900 MHz XTend RF Modem is MaxStream’s longest range drop-in wireless solution. Out-of-box, the RF modem is equipped to sustain long range wireless links between devices. Simply enter serial data into one modem and the data surfaces on the other end of the wireless link.

The modem transfers a standard asynchronous serial data stream between two or more modems. Its built-in RS-232, RS-485 and RS-422 interface allows for rapid integration into existing data systems.

1.1. Features Overview

Long Range at a Low Cost

1 Watt Power Output (1 mW – 1 W, selectable)

Easy-to-Use

No configuration required

Range (@ 9600 bps throughput data rate):

• Indoor/Urban: up to 3000’ (900 m)

Advanced configurations available through AT & binary Commands

• Outdoor line-of-sight:

up to 14 miles (22 km) w/ dipole antenna

External DIP Switch configurations

7 to 28 V power supply

• Outdoor line-of-sight:

up to 40 miles (64 km) w/ high gain antenna

Continuous RF data stream of up to

115.2 kbps

Range (@ 115200 bps throughput data rate):

• Indoor/Urban: up to 1500’ (450 m)

True Peer-to-Peer (no “master” required),

Point-to-Point, Point-to-Multipoint & Multidrop

Transparent Operation – Wireless links replace serial wires

• Outdoor line-of-sight:

up to 7 miles (11 km) w/ dipole antenna

• Outdoor line-of-sight:

up to 20 miles (32 km) w/ high gain antenna

MODBUS, , , &

I/O Support

Receiver Sensitivity: -110 dBm (@ 9600 baud),

–100 dBm (@ 115200 baud)

XII™ Interference Immunity

Advanced Networking & Security

Software-selectable serial interfacing

Power-saving Sleep Modes

Streaming, Acknowledged & Multi-

Send RF Communication Options

Free & Unlimited Technical Support

Retries and Acknowledgements

FHSS (Frequency Hopping Spread Spectrum)

10 hopping channels - each with over 65,000 network addresses available

256-bit AES Encryption (Refer to KY Command [p29] to implement)

1.1.1. Worldwide Acceptance

FCC Approved (USA - Go to Appendix A [p46] for FCC Requirements)

Systems that contain XTend Modems inherit MaxStream’s FCC Certification

IC Approved (Canada)

ISM (Industrial, Scientific & Medical) license-free 902-928 MHz frequency band

Manufactured under ISO 9001:2000 registered standards

   © 2005 MaxStream, Inc. Confidential and Proprietary  4 

9XTend‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v1.2.4 

1.2. Product Overview

The XTend-PKG-R RF Modem comes configured to provide immediate long range wireless links between devices. The RF modem can be configured for additional functionality through the use of

standard AT and binary commands [Refer to the Command Mode [p18] & Modem Configuration

[p20] sections for programming options].

1.2.1. Specifications

Table 1‐01. XTend‐PKG‐R RS‐232/485 RF Modem Specifications 

XTend-PKG-R 900 MHz RF Modem Specifications

Performance

Transmit Power Output

@ 9600 bps Throughput Data Rate

1 mW - 1 W (software selectable)

Indoor/Urban Range

Outdoor

RF line-of-sight Range

Interface Data Rate

(selectable using BD Command)

RF Data Rate

Up to 3000’ (900 m)

Up to 14 miles (22 km) w/ dipole antenna

Up to 40 miles (64 km) w/ high-gain antenna

1200 - 230400 bps

Receiver Sensitivity

10000 bps

-110 dBm

Power Requirements (refer also to Table 1-02 below)

Receive Current 110 mA

16 sec cyclic sleep (SM=8) 20 mA

8 sec cyclic sleep (SM=7) 21 mA

Idle

Currents

4 sec cyclic sleep (SM=6) 24 mA

2 sec cyclic sleep (SM=5) 30 mA

1 sec cyclic sleep (SM=4) 39 mA

Pin Sleep Power Down 17 mA

Serial Port Sleep Power Down

Networking & Security

45 mA

Frequency

RF Transmission

902-928 MHz ISM Band

FHSS (Frequency Hopping Spread Spectrum)

110 mA

19 mA

19 mA

20 mA

22 mA

25 mA

17 mA

45 mA

@ 115200 bps Throughput Data Rate

1 mW - 1 W (software selectable)

Up to 1500’ (450 m)

Up to 7 miles (11 km) w/ dipole antenna

Up to 20 miles (32 km) w/ high-gain antenna

1200 - 230400 bps

125000 bps

-100 dBm

Supported Network Topologies

Channel Capacity

Encryption

Physical Properties

Size

Weight

Serial Connector

Operating Temperature

Antenna

Peer-to-Peer, Point-to-Point, Point-to-Multipoint & Multidrop

10 hop sequences share 50 frequencies

256-bit AES Encryption – Refer to KY Command [p29] to implement

2.750” x 5.500” x 1.125” (6.99cm x 13.97” x 2.86cm)

7.1 oz. (200g)

DB-9

-40 to 85º C (industrial)

Connector

Type

Impedance

RPSMA (Reverse-polarity SMA)

½ wave dipole whip, 6.75” (17.15 cm), 2.1 dBi Gain

50 ohms unbalanced

Certifications (visit www.maxstream.net for complete list)

FCC Part 15.247 OUR-9XTEND

Industry Canada (IC) 4214A-9XTEND

Table 1‐02. XTend RF Modem Specifications – Relative to user‐selected TX Power Output 

Power Requirements (TX currents relative to each TX Power Output option)

Transmit Power Output

Transmit Current @9600 baud

(9 VDC supply voltage, typical)

Transmit Current @115K baud

(9 VDC supply voltage, typical)

1 mW

110 mA

110 mA

10 mW

145 mA

140 mA

100 mW

250 mA

245 mA

500 mW

510 mA

500 mA

1 W

900 mA

800 mA

   © 2005 MaxStream, Inc. Confidential and Proprietary  5 

9XTend‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v1.2.4 

1.3. XTend-PKG-R Interface

Figure 1‐01. Front View 

1‐01c. Serial Port 

1‐01d. RSSI LEDs 

1‐01b. I/O & Power LEDs  

1‐01e. Power Connector* 

1‐01a. Config Switch 

* Note: The XTend RF Modem can accept      voltages as low as 5 (±5%) V. 

Contact MaxStream technical support           

(801) 765‐9885 to implement this option. 

Figure 1‐02. Back View 

1‐02a. DIP Switch 

1‐02b. Antenna Port 

Figure 1‐03. DIP Switch Settings 

1-01a. Config (Configuration) Switch

The Configuration Switch provides an alternate method for entering into Command Mode. To enter Command Mode at the default RF data rate of the RF modem, depress the Config

Switch for two seconds.

1-01b. I/O & Power LEDs

LEDs indicate modem activity as follows:

Yellow (top LED) = Serial Data Out (to host)

Green (middle) = Serial Data In (from host)

Red (bottom) = Power/TX Indicator (Red light is on when powered and pulses off briefly during RF transmission)

1-01c. Serial Port

Standard female DB-9 (RS-232) DCE connector – Connector can be also used for RS-485 and RS-422 connections.

1-01d. RSSI LEDs

RSSI LEDs indicate the amount of fade margin present in an active wireless link. Fade margin is the difference between the incoming signal strength and the modem’s receiver sensitivity.

3 LEDs ON = Very Strong Signal (> 30 dB fade margin)

2 LEDs ON = Strong Signal (> 20 dB fade margin)

1 LED ON = Moderate Signal (> 10 dB fade margin)

0 LED ON = Weak Signal (< 10 dB fade margin)

1-01e. Power Connector *

7-28 VDC Power Connector.

1-02a. DIP Switch

During the power-on sequence, the DIP Switch automatically configures the XTend Modem to operate in different modes.

Each time the RF modem is powered-on, intelligence inside the

XTend RF Modem programs the modem according to the positions of the DIP Switch. [Refer to Figure 1-03 for DIP

Switch settings].

1-02b. Antenna Port

Port is a 50Ω RF signal connector for connecting to an external antenna. The connector type is RPSMA (Reverse Polarity SMA) female. The connector has threads on the outside of a barrel and a male center conductor.

Refer to table in the 

“Automatic DIP Switch 

Configurations” section 

[p20] for information about 

configurations triggered by  the DIP Switch. 

   © 2005 MaxStream, Inc. Confidential and Proprietary  6 

9XTend‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v1.2.4 

2. Interfacing Protocol 

The XTend-PKG-R RF Modem supports the following interfacing protocols:

• RS-232

• RS-485 (2-wire) Half-Duplex

• RS-485 (4-wire) and RS-422

2.1. RS-232 Operation

2.1.1. DIP Switch Settings & Pin Signals

 

 

 

 

 

 

 

Figure 2‐01.   

RS‐232 DIP Switch Settings   

 

     

 

 

 

DIP Switch settings are read and applied  only while powering‐on. 

 

 

 

 

 

 

    

Figure 2‐02. 

Serial Connector 

 

 

 

 

Pins used on the female RS‐232 (DB‐9)   

 

Table 2‐01. RS‐232 Signals and their implementations on the XTend RF Modem 

(Low‐asserted signals are distinguished by horizontal line over pin name.) 

 

DB-9 Pin

RS-232

Name

Pin

Reference

Name*

Description Implementation

 

 

         

2

3

4

7

8

RXD

TXD

DTR

/ CMD

Data-Carrier-Detect

DO Received Data

DI Transmitted Data

GPI2 / SLEEP Data-Terminal-Ready

GPI1 /

CMD

/

GPO1 / /

RS-485 TX EN

Data-Set-Ready

Request-to-Send

Connected to DSR (pin6)

Serial data exiting the RF Modem (to host)

Serial data entering into the RF modem (from host)

Can enable POWER-DOWN on the RF Modem

Ground

Connected to DCD (pin1)

Provides flow control or enables “Command Mode” on the RF Modem

Optional power input that is connected internally to the positive lead of the front power connector

            

  

* The Pin Reference Name provides an associative tag that references commands used to define pin behavior. 

GPI stands for “General Purpose Input” and GPO stands for “General Purpose Output”. For example, the CD 

Command is used to define the behavior of GPIO2 (pin 1).  

   © 2005 MaxStream, Inc. Confidential and Proprietary  7 

9XTend‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v1.2.4 

2.1.2. Wiring Diagrams

RS-232 DTE Device to a DCE RF Modem

Figure 2‐03.   RS‐232 DTE (male connector) device wired to an XTend RF Modem (female connector) 

DCE RF Modem to an RS-232 DCE Device

Figure 2‐04.   XTend RF Modem (female connector) wired to an RS‐232 DTE (male connector) device 

Sample Wireless Connection: DTE Ù DCE DCE Ù DCE

Figure 2‐05.   Typical wireless connection used for serial communications between DTE and DCE devices 

   © 2005 MaxStream, Inc. Confidential and Proprietary  8 

9XTend‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v1.2.4 

2.2. RS-485 (2-wire) Operation

2.2.1. DIP Switch Settings & Pin Signals

 

 

Figure 2‐06.   

RS‐485 (2‐wire) Half‐Duplex   

 

DIP Switch Settings   

 

 

 

 

 

 

Figure 2‐08.       

RS‐485 (2‐wire) with Termination (optional) 

 

 

 

   

Figure 2‐07. 

   

 

 

 

 

 

Pins used on the female RS‐232 (DB‐9)             

Serial Connector 

 

 

 

 

 

Termination is the 120 Ω resistor between T+ and T‐. 

 

DIP Switch settings are read and applied only while powering‐on. 

Note: Refer to Figures 2-15 and 2-16 for RJ-45 connector pin designations used in

            

            

Table 2‐02. RS‐485 (2‐wire half‐duplex) Signals and their implementations on the XTend RF Modem 

DB-9 Pin

2

RS-485 Name

T/R- (TRA)

Description

Negative Data Line

Implementation

Transmit serial data to and from the

XTend RF Modem

8 T/R+ (TRB) Positive Data Line

Ground

Transmit serial data to and from the

XTend RF Modem

9 PWR Power

1, 3, 4, 6, 7

Optional power input that is connected internally to the front power connector not used

2.2.2. Wiring Diagram

RS-485 (2-wire) Half-Duplex

Figure 2‐09.   XTend RF Modem in an RS‐485 (2‐wire) half‐duplex environment 

   © 2005 MaxStream, Inc. Confidential and Proprietary  9 

9XTend‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v1.2.4 

2.3. RS-485 (4-wire) & RS-422 Operation

2.3.1. DIP Switch Settings & Pin Signals

Figure 2.10.   

RS‐485 (4‐wire) and RS‐422   

 

DIP Switch Settings   

 

 

 

 

 

 

Figure 2.12.         

RS‐485 (4‐wire) & RS‐422 with Termination (optional) 

Termination is the 120 Ω resistor between T+ and T‐. 

 

Figure 2.11.       

Pins used on the female RS‐232 (DB‐9)             

Serial Connector 

       

DIP Switch settings are read and applied only while powering‐on. 

Table 2‐03. RS‐485/422 (4‐wire) Signals and their implementations with the XTend‐PKG‐R RF Modem 

DB-9 Pin

RS-485/422

Name

Description Implementation

Transmit Negative

Data Line

Receive Negative

Data Line

Serial data sent from the XTend RF Modem

Serial data received by the XTend RF Modem

Ground

Receive Positive

Data Line

Transmit Positive

Data Line

Serial data received by the XTend RF Modem

Serial data sent from the XTend RF Modem

9 PWR Power

1, 4, 6

Optional power input that is connected internally to the front power connector not used

2.3.2. Wiring Diagrams

RS-485 (4-wire) Half-Duplex

Figure 2‐13.   XTend RF Modem in an RS‐485 (4‐wire) environment 

            

            

   © 2005 MaxStream, Inc. Confidential and Proprietary  10 

9XTend‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v1.2.4 

RS-422

Figure 2‐14.   XTend RF Modem in an RS‐485 (4‐wire) environment 

2.3.3. RS-485/422 Connection Guidelines

The RS-485/422 protocol provides a solution for wired communications that can tolerate high noise and push signals over long cable lengths. RS-485/422 signals can communicate as far as

4000 feet (1200 m). RS-232 signals are suitable for cable distances up to 100 feet (30.5 m).

RS-485 offers multi-drop capability in which up to 32 nodes can be connected. The RS-422 protocol is used for point-to-point communications.

Suggestions for integrating the XTend Modem with the RS-485/422 protocol:

1. When using Ethernet twisted pair cabling: Select wires so that T+ and T- are connected to each wire in a twisted pair. Likewise, select wires so that R+ and R- are connected to a twisted pair. (For example, tie the green and white/green wires to T+ and T-.) works well: Pin3 to T+, Pin4 to R+, Pin5 to R-, Pin6 to T-

3. Note that the connecting cable only requires 4 wires (even though there are 8 wires).

4. When using phone cabling (RJ-11) – Pin2 in the cable maps to Pin3 on opposite end of cable and Pin1 maps to Pin4 respectively.

 

 

 

 

 

 

Figure 2‐15.   Male DB‐9 to RJ‐45 Adapter (yellow) 

 

Figure 2‐16.   Female DB‐9 to RJ‐45 Adapter (green) 

An XTend RF Modem Accessories Kit is available that includes connectors that facilitate RS-485/422 and other serial communications. Refer to the Development Guide in Appendix B for information concerning the connectors and tools included in the kit.

   © 2005 MaxStream, Inc. Confidential and Proprietary  11 

9XTend‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v1.2.4 

3. Modem Operation 

WARNING: When operating at 1 Watt power output, observe a minimum separation distance of 2’ (0.6 m) between modems.

Transmitting in close proximity of other modems can damage modem front ends.

3.1. Serial Communications

3.1.1. RS-232 and RS-485/422 Data Flow

The XTend-PKG-R RF Modem interfaces to a host device through a standard RS-232 (DB-9) connector. Devices that have a standard RS-232 serial port can connect directly through the pins of the XTend RF Modem as shown in the figure below.

Figure 3‐01. System Data Flow in an RS‐232 environment 

3.1.2. Host and RF Modem Settings

Serial communications between a host and an XTend RF Modem are dependent upon having matching baud rate, parity, stop bit & number of data bits settings. Refer to the table below to ensure host serial port settings match those of the XTend RF Modem.

Table 3‐01. Parameter values critical to serial communications between the RF Modem and host 

Parameter Setting

Baud (Serial Data Rate)

Number of Data Bits

Parity

Number of Stop Bits

XTend RF Modem Default Parameter Value

9600 bps

8

None

1

(BR parameter = 3)

(NB parameter = 0)

(NB parameter = 0)

(NB parameter = 0)

Both the XTend RF Modem and host (PC) settings can be viewed and adjusted using MaxStream’s proprietary X-CTU Software. Use the “Terminal” or “Modem Configuration” tabs to configure the

RF Modem settings. Use the “PC Settings” tab to configure host settings. Refer to the Advanced

Programming and X-CTU Software sections for more information.

   © 2005 MaxStream, Inc. Confidential and Proprietary  12 

9XTend‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v1.2.4 

3.1.3. Flow Control

Figure 3‐02. Internal Data Flow Diagram 

DI (Data In) Buffer and Flow Control

When serial data enters the XTend Modem through the DI Pin, the data is stored in the DI Buffer until it can be transmitted.

When the RB and RO parameter thresholds are satisfied (refer to Transmit Mode section [p14] for

more information), the modem attempts to initialize an RF connection. If the modem is already receiving RF data, the serial data is stored in the modem’s DI Buffer. The DI buffer stores at least

2.1 KB. If the DI buffer becomes full, hardware or software flow control must be implemented in order to prevent overflow (loss of data between the host and XTend Modem).

How to eliminate the need for flow control:

1. Send messages that are smaller than the DI buffer size. The size of the DI buffer varies according to the packet size (PK parameter) and the parity setting (NB parameter) used.

2. Interface at a lower baud rate (BD parameter) than the RF data rate (BR parameter).

Two cases in which the DI Buffer may become full and possibly overflow:

1. If the serial interface data rate is set higher than the RF data rate of the modem, the modem will receive data from the host faster than it can transmit the data over-the-air.

2. If the modem is receiving a continuous stream of RF data or if the modem is monitoring data on a network, any serial data that arrives on the DI pin is placed in the DI Buffer. The data in the DI buffer will be transmitted over-the-air when the modem no longer detects RF data in the network.

Hardware Flow Control ( ). When the DI buffer is 17 bytes away from being full; by default, the modem de-asserts (high) to signal to the host device to stop sending data [refer

to FT (Flow Control Threshold, p28) and CS (GPO1 Configuration, p26) Commands.].

asserted after the DI Buffer has 34 bytes of memory available.

is re-

Software Flow Control (XON). XON/XOFF software flow control can be enabled using the FL

(Software Flow Control) Command [p27]. This option only works with ASCII data.

DO (Data Out) Buffer & Flow Control

When RF data is received, the data enters the DO buffer and is sent out the serial port to a host device. Once the DO Buffer reaches capacity, any additional incoming RF data is lost. The DO buffer stores at least 2.1 KB.

Two cases in which the DO Buffer may become full and possibly overflow:

1. If the RF data rate is set higher than the interface data rate of the modem, the modem will receive data from the transmitting modem faster than it can send the data to the host.

2. If the host does not allow the modem to transmit data out from the DO buffer because of being held off by hardware or software flow control.

Hardware Flow Control ( ). If

is enabled for flow control (RT Parameter = 2, p35), data

will not be sent out the DO Buffer as long as is de-asserted.

Software Flow Control (XOFF). XON/XOFF software flow control can be enabled using the FL

(Software Flow Control) Command [p27]. This option only works with ASCII data.

   © 2005 MaxStream, Inc. Confidential and Proprietary  13 

9XTend‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v1.2.4 

3.2. Modes of Operation

XTend RF Modems operate in five modes.

Figure 3‐03. Modes of Operation  

The RF modem can only be in one mode at a time.  

3.2.1. Idle Mode

When not receiving or transmitting data, the modem is in Idle Mode. The modem uses the same amount of power in Idle Mode as it does in Receive Mode.

The modem shifts into the other modes of operation under the following conditions:

• Serial data is received in the DI Buffer (Transmit Mode)

• Valid RF data is received through the antenna (Receive Mode)

• Command Mode Sequence is issued (Command Mode)

• Sleep Mode condition is met (Sleep Mode)

The modem automatically transitions to Idle Mode after responding to these conditions.

3.2.2. Transmit Mode

When the first byte of serial data is received from the host in the DI buffer, the modem attempts to shift to Transmit Mode and initiate an RF connection with other modems. After transmission is finished, the modem returns to Idle Mode.

RF transmission begins after either of the following criteria is met:

1. RB bytes have been received by the host and are pending for RF transmission.

[RB (Packetization Threshold) Command]

2. At least one character has been received by the host and is pending for RF transmission, and

RO character times of silence have been observed on the host.

[RO (Packetization Timeout) Command]

Figure 3‐04. Transmit Mode Data Flow 

The character timeout trigger can be disabled by setting RO to zero.

In this case, transmission will not begin until RB bytes have been received and are pending for RF transmission. The RB parameter may be set to any value between 1 and the RF packet size (PK), inclusive. Note that transition to

Transmit Mode cannot take place during RF reception; the RF reception must complete before the modem can transition into

Transmit Mode.

   © 2005 MaxStream, Inc. Confidential and Proprietary  14 

9XTend‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v1.2.4 

After either of the RB and RO conditions are met, the modem then initializes a communications channel. Serial data in the DI buffer is grouped into RF packets (up to 2048 bytes in each packet

- refer to PK (Maximum RF Packet Size) Command), converted to RF data and then is transmitted over-the-air until the DI buffer is empty.

Channel initialization is the process of sending an RF initializer that synchronizes receiving modems with the transmitting modem. During channel initialization, incoming serial data accumulates in the DI buffer.

RF data, which includes the payload data, follows the RF initializer. The payload includes up to the maximum packet size (PK Command) bytes. As the TX modem nears the end of the transmission, it inspects the DI buffer to see if more data exists to be transmitted. This could be the case if more than PK bytes were originally pending in the DI buffer or if more bytes arrived from the host during transmission. If more data is pending, the transmitting modem instructs all listening modems that a subsequent packet is coming. Receiving modems move to the new frequency and listen for the subsequent packet.

Refer to the RF Communication Options [p41] section for information and state diagrams that

illustrate channel initialization and the sequence of events that follow.

RF Packet

Figure 3‐05. RF Packet Components 

* When streaming multiple RF packets, the RF Initializer is only sent in front of the first packet. 

RF Initializer

An RF initializer is sent each time a new connection sequence begins. The RF initializer contains channel information that notifies receiving modems of information such as the hopping pattern used by the transmitting modem. Channel initialization takes 5 ms at the 115k RF data rate and

54 ms at the 9600 RF data rate. The first transmission always sends an RF initializer.

An RF initializer can be of various lengths depending on the amount of time determined to be required to prepare a receiving modem. For example, a wake-up initializer is a type of RF initializer used to wake remote modems from Sleep Mode (Refer to the FH, LH, HT and SM

Commands for more information). The length of the wake-up initializer should be longer than the length of time remote modems are in cyclic sleep.

Header

The header contains network addressing information that filters incoming RF data. The receiving modem checks for matching a Hopping Channel, VID and Destination Address. Data that does not pass through all three network security layers is discarded.

Figure 3‐06. Network Layers Contained in the Header 

   © 2005 MaxStream, Inc. Confidential and Proprietary  15 

9XTend‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v1.2.4 

CRC (Cyclic Redundancy Check)

To verify data integrity and provide built-in error checking, a 16-bit CRC (Cyclic Redundancy

Check) is computed for the transmitted data and attached to the end of each RF packet before transmission. On the receiving end, the receiving modem computes the CRC on all incoming RF data. Received data that has an invalid CRC is discarded [Refer to the Receive Mode section].

3.2.3. Receive Mode

If a modem detects RF data while in Idle Mode, the modem transitions into Receive Mode to start receiving RF packets. Once a packet is received, it goes through the receiving end of a CRC

(cyclic redundancy check) to ensure that the data was transmitted without error. If the CRC data bits on the incoming packet are invalid, the packet is discarded. If the CRC is valid, the packet is placed the DO Buffer.

Figure 3‐07. Receive Mode Data Flow 

* Refer to the Addressing Options section (under the RF Communication Options chapter) for more information  about address recognition. 

The modem returns to Idle Mode after valid RF data is no longer detected or after an error is detected within the received RF data. If serial data is stored in the DI buffer while the modem is in Receive Mode, the serial data will be transmitted after the modem is finished receiving data and returns to Idle Mode.

   © 2005 MaxStream, Inc. Confidential and Proprietary  16 

9XTend‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v1.2.4 

3.2.4. Sleep Mode

Software Sleep

Sleep Modes enable the XTend Modem to operate at minimal power consumption when not in use. Three Sleep Mode options are available:

• Host Controlled (Pin Sleep)

• Wake on Serial Port activity (Serial Port Sleep)

• Wake on RF activity (Cyclic Sleep)

For the modem to transition into Sleep Mode, SM (Sleep Mode) Parameter must have a non-zero value and one of the following must occur:

1. The modem is idle (no data transmission or reception) for a user-defined period of time [See

ST (Time before Sleep) Command]

[OR]

2. GPI2 pin is asserted [GPI2 is equivalent to DTR (Data-Terminal-Ready) under RS-232

operation. Refer to the RS-232 Operation [p7] section for more information.]

While in Sleep Mode, the modem will not transmit or receive data until the modem first shifts back to Idle Mode. The return to Idle Mode is triggered by the de-assertion of GPI2 or the arrival of a serial byte through the DI pin. Sleep Mode is enabled and disabled using SM Command.

Table 3‐02. Summary of Sleep Mode Configurations 

Sleep Mode

Setting

Pin Sleep

(SM=1)

Serial Port Sleep

(SM=2)

Cyclic Sleep

(SM=4-8)

Transition into

Sleep Mode

Transition out of

Sleep Mode

Host can shut down and wake modems. Assert GPI2

(SLEEP) pin.

Note: The module will complete a transmission or reception before activating

Pin Sleep.

De-Assert GPI2 (SLEEP) pin.

Automatic transition into

Sleep Mode after userdefined period of inactivity

(no transmitting or receiving). Period of inactivity set using ST

Command.

When serial byte is received on the DI pin.

Transitions into and out of Sleep Mode in cycles (userselectable wake-up interval of time set by SM Command).

The Cyclic Sleep interval time must be shorter than “Wakeup Initializer Timer” (set by LH Command).

(Can be forced into Idle Mode using GPI2 (SLEEP) pin if

PW (Pin Wake-up) Command is issued.)

Related

Commands

SM

SM, ST

HT, LH, PW, SM, ST

Power

Consumption

Typically 17 mA

Typically 45 mA

Typically 25 mA

(when sleeping, SM=4 ,

1 sec, @120K baud)

 

For more information about Sleep Modes, refer to the individual commands listed in “Related Commands”  column of the table. SM Command is the best starting point. 

3.2.5. Shutdown

Hardware Sleep

Shutdown Mode offers the lowest power mode available to MaxStream modem users (< 1 µA).

This mode is not supported by the stand-alone XTend RF Modem, but is available through the

OEM RF Module that is mounted inside the stand-alone XTend RF Modem.

Contact MaxStream Technical Support for more information.

   © 2005 MaxStream, Inc. Confidential and Proprietary  17 

9XTend‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v1.2.4 

3.2.6. Command Mode

To set or read modem parameters; the modem must first enter Command Mode (a state in which incoming characters are interpreted as commands). Two command types are available:

• AT Commands

• Binary Commands

For modified parameter values to persist in the modem’s registry, changes must be saved to nonvolatile memory using WR (Write) Command. Otherwise, parameters are reset to previously stored values after the modem is powered off and then on again.

AT Command Mode

To enter AT Command Mode:

1. Send the 3-character command sequence “+++” and observe guard times before and after the command characters. [See “Default AT Command Mode Sequence” below.]

Use the “Terminal” tab (or other serial communications software) of the X-CTU Software to enter the sequence.

[OR]

2. Force entrance into AT Command Mode by keeping the configuration switch [Figure 1-01a,

p6] pressed for two seconds.

Default AT Command Mode Sequence:

• No characters sent for one second [see BT (Guard Time Before) Command]

• Input three plus characters (“+++”) within one second [see CC (Command Sequence

Character) Command.]

• No characters sent for one second [see AT (Guard Time After) Command.]

To Send AT Commands to the RF Modem:

Figure 3‐08. Syntax for sending XTend AT Commands 

NOTE: To read a current parameter value stored in a register, leave the parameter field blank.

The preceding example would change the modem Destination Address “1F”. To store the new value to the modem’s non-volatile (long term) memory, use the WR (Write) Command.

The “Modem Configuration” tab of the X-CTU Software [p22] provides a software user interface

that facilitates the programming of RF modems. A more in depth look at modem programming is

in the Advanced Configuration section [p20].

To Exit Command Mode:

1. If no valid AT Commands are received within the time specified by CT (Command Mode

Timeout) Command, the modem automatically returns to Idle Mode.

[OR]

2. Send ATCN (Exit Command Mode) Command.

For an example on that illustrates programming the modem using AT Commands, refer to the

‘Terminal tab’ section on p21.

   © 2005 MaxStream, Inc. Confidential and Proprietary  18 

9XTend‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v1.2.4 

Binary Command Mode

Sending and receiving parameter values using binary commands is the fastest way to change the operating parameters of the XTend RF Modem. Binary commands are used most often to sample signal strength (DB parameter) and/or error counts; or change modem addresses and channels for polling data systems. Since the sending and receiving of parameter values takes place through the same serial data path as 'live' data (received RF payload), interference between the two data types can be a concern.

Common questions about using binary commands:

• What are the implications of asserting CMD while live data is being sent or received?

• After sending serial data, is there a minimum time delay before CMD can be asserted?

• Is a delay required after CMD is de-asserted before payload data can be sent?

• How does one discern between live data and data received in response to a command?

The CMD pin must be asserted in order to send binary commands to the RF modem. The CMD pin can be asserted to recognize binary commands anytime during the transmission or reception of data. The status of the CMD signal is only checked at the end of the stop bit as the byte is shifted into the serial port. The application does not allow control over when data is received, except by waiting for dead time between bursts of communication.

If the command is sent in the middle of a stream of payload data to be transmitted, the command will essentially be executed in the order it is received. If the radio is continuously receiving data, the radio will wait for a break in the received data before executing the command.

The signal will frame the response coming from the binary command request [Figure 3-09].

A minimum time delay of 100 µs (after the stop bit of the command byte has been sent) must be observed before the CMD pin can be de-asserted. The command executes after all parameters associated with the command have been sent. If all parameters are not received within 0.5 seconds, the modem returns to Idle Mode.

Note: When parameters are sent, they are two bytes long with the least significant byte sent first.

Binary commands that return one parameter byte must be written with two parameter bytes.

Refer to p22 for a binary programming example.

Commands can be queried for their current value by sending the command logically ORed (bitwise) with the value 0x80 (hexadecimal) with CMD asserted. When the binary value is sent (with no parameters), the current value of the command parameter is sent back through the DO pin.

Figure 3‐09. Binary Command Write then Read 

Signal #4 is CMD 

Signal #1 is the DIN signal to the modem 

Signal #2 is the DOUT signal from the modem 

Signal #3 is    

 

 

In this graph, a value was written to a register and then  read out to verify it. While not in the middle of other  received data, note that the  response out of the modem. 

 signal outlines the data 

IMPORTANT: For the XTend Modem to recognize binary commands, the RT (GPI1 Configuration) parameter must be set to one. If binary programming is not enabled (RT != 1), the modem will not recognize the data as binary commands.

   © 2005 MaxStream, Inc. Confidential and Proprietary  19 

9XTend‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v1.2.4 

4. Modem Configuration 

4.1. Automatic DIP Switch Configurations

Each time an RF Modem is powered on, AT commands are sent to the on-board RF module as dictated by the positions of the DIP switches. DIP switch configurations are sent automatically during the power-on sequence and affect modem parameter values as shown in the table below.

Figure 4‐01. DIP Switches   

Table 4‐01. Power‐up Options ‐ Commands sent as result of DIP Switch Settings (SW = DIP Switch) 

Switches Behavior

Switches 1 & 2

(Restore Defaults /

Serial Interfacing)

Switches 5 & 6

(TX/RX Modes)

Condition

If SW1 & SW2 are ON (up)

If SW1 is ON (up)

If SW1 is OFF (down)

If SW5 is ON (up) &

SW6 is OFF (down)

If SW5 & SW6 are

OFF (down)

If SW5 is OFF (down) &

SW6 is ON (up)

If SW5 is ON (up) &

SW6 is ON (up)

Restore Defaults

RS-232 Operation

RS-485/422

Operation

Peer-to-Peer

Multipoint Base

Multipoint Remote

User Defined

Commands Sent During Power-up

ATRE

ATWR

ATCS 0

(Restore Defaults)

(Write defaults to non-volatile memory)

(RS-232, CTS flow control)

ATCS 3 (RS-485 or RS-422 Operation)

ATAM

ATDT FFFF

ATMT 3

(Auto-set MY, MY = unique)

(Destination Address)

(Multi-Transmit option)

ATMY 0

ATDT FFFF

ATMT 3

ATAM

ATDT 0

ATMT 0

ATRR A

(Source Address)

(Destination Address)

(Multi-Transmit option)

(Auto-set MY, MY = unique)

(Destination Address)

(Multi-Transmit option)

(Retries)

Processor is disabled and AT Commands are not sent to the modem (except for CS command as shown below.)

IMPORTANT: To avoid overwriting previously stored custom configurations (due to the automatic configurations that take place each time the RF modem is powered-on), it is necessary to disable a processor located inside the RF modem.

To disable the processor, turn switches 5 and 6 ON (up). When switches 5 and 6 are ON, only the CS command is sent [refer to table below].

Table 4‐02. User Defined Mode (Switches 5 and 6 are ON (up)) 

DIP Switches ON (up)

SW1, SW5 and SW6

SW2, SW5 and SW6

SW5 and SW6 only

Condition

If CS = 0, 1, 2 or 4

If CS = 3

If CS = 2

If CS = 0, 1, 2, 3 or 4

Command Sent During Power-up

CS parameter remains the same

ATCS 0

ATCS 2

ATCS 3

(RS-232 operation,

(GPO1 high)

(RS-485/422 Operation)

flow control)

   © 2005 MaxStream, Inc. Confidential and Proprietary  20 

9XTend‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v1.2.4 

4.2. Programming Examples

For information about entering and exiting AT and Binary Command Modes, refer to the

Command Mode section [p18].

4.2.1. AT Commands (Using X-CTU Software)

MaxStream has provided X-CTU software for programming the modem using an extensive list of

AT Commands. The X-CTU software provides an interface that is divided into four tabs that facilitate the following functions:

• PC Settings tab - Setup PC serial port to interface with an XTend RF Modem

• Range Test tab – Test XTend RF Modem's range in varying environments

• Terminal tab – Configure and read XTend RF Modem parameters using AT Commands

• Modem Configuration tab – Configure and read RF Modem parameters

To install the X-CTU Software:

Double-click the ‘setup_X-CTU.exe’ file that is located on the MaxStream CD and under the

‘Downloads’ section of the following web page: www.maxstream.net/helpdesk/. Then follow the prompts of the installation screens.

PC Settings tab

As stated in the Serial Communications section [p12]; in order to communicate data to the RF

modem through the PC, baud (serial data rate), data bit, parity and stop bit settings on the PC serial port must match those of the RF modem. The ‘PC Settings’ tab provides a software user interface that facilitates the modification of PC serial port setting.

PC Setup

1. Set the DIP Switch to RS-232 mode. Switch 1 is ON (up) and the remaining 5 switches are

OFF (down).

2. Connect the male DB-9 connector of the PC with the female DB-9 connector of the RF modem using an RS-232 cable.

3. Power the RF modem through the power connector.

4. Go to the PC Settings tab and select parameter values from the dropdown lists that match the current parameter values of the RF modem.

Figure 4‐02. Setup for RF Modem Configurations through X‐CTU Software 

Terminal tab

A terminal program has been built into the X-CTU software and is located under the ‘Terminal’ tab. The Terminal tab provides an easy-to-use interface for programming the modem.

Multiple AT Commands. Multiple AT commands can be entered on one line with one carriage return at the end of the line. Each command must be delimited by a comma (spaces in between are optional). The “AT” prefix is only sent before the first command and should not be included with subsequent commands in a line.

System Response. When a command is sent to the modem, the modem will parse and execute the command. Upon successful execution of a command, the modem returns an “OK” message. If execution of a command results in an error, the modem returns an “ERROR” message.

   © 2005 MaxStream, Inc. Confidential and Proprietary  21 

9XTend‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v1.2.4 

EXAMPLE: Restore RF Modem Default Parameters using the Terminal tab:

Note:  Do not send  commands to the  module during flash  programming (when  parameters are being  written to the module  registry).   

Wait for the ʺOKʺ  system response that  follows the ATWR  command before  entering the next  command or use flow  control. 

Example: Both of the following examples restore the XTend Modem’s factory defaults and save the parameters to non-volatile memory.

Method 1 (One line per command)

Issue AT Command

+++

System Response

OK<CR> (Enter into AT Command Mode)

ATCN <Enter> OK<CR> (Exit AT Command Mode)

Method 2 (Multiple commands on one line)

Issue AT Command

+++

ATRE, WR <Enter>

ATCN <Enter>

System Response

OK<CR> (Enter into AT Command Mode)

OK<CR> (Execute multiple commands)

OK (Exit AT Command Mode)

NOTE: Default parameter values of the RF Modem can also be restored by selecting the ‘Restore’ button located on the Modem Configuration tab [refer to the example below].

Modem Configuration tab

The ‘Modem Configuration’ tab of the X-CTU software can be used to activate advanced functions.

EXAMPLE: Read & Restore Default Parameters using the Modem Configuration tab:

The following steps show how to read currently stored modem parameter values; then restore the modem parameters to their factory-default states.

1. Open the X-CTU program (Start --> Programs --> MaxStream --> X-CTU):

2. Under the “PC Settings” tab, select the PC Serial Com Port from the dropdown list that will be used to connect to the RF Modem.

3. Select a "Baud rate" to match the default RF data rate of the RF Modem. Use default values for all other fields.

4. Select the “Modem Configuration” tab.

5 Select the ‘Read’ button to read currently stored parameter values of the modem.

6. Select the ‘Restore’ button to restore factory-default parameter values.

7. Select the ‘Write’ button to save default values to non-volatile memory.

4.2.2. Binary Commands

To Send Binary Commands:

Example: Use binary commands to change the RF modem’s destination address to 0x1A0D and save the new address to non-volatile memory.

1. RT Command must be set to ‘1’ in AT Command Mode to enable binary programming.

2. Assert CMD (Pin is driven high). (Enter Binary Command Mode)

3. Send Bytes [parameter bytes must be 2 bytes long]:

0D

1A

4. De-assert CMD (Pin is driven low).

(Least significant byte)

(Most significant byte)

WR Command)

(Exit Binary Command Mode)

Note: is high when command is being executed. Hardware flow control must be disabled as will hold off parameter bytes.

   © 2005 MaxStream, Inc. Confidential and Proprietary  22 

9XTend‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v1.2.4 

4.3. Command Reference

Table 4‐03. XTend Commands as of firmware v1.2.4 (“d” denotes decimal equivalent) 

AT

Command

Binary

Command

AT Command Name Parameter Range

DB

DT

E0

E1

CF

CN

CS

CT

%V

AM

AT

BD

BR

BT

CC

CD

0x3B (59d)

0x40 (64d)

0x05 (5d)

0x15 (21d)

0x39 (57d)

0x04 (4d)

0x13 (19d)

0x28 (40d)

-

0x09 (9d)

0x1F (31d)

0x06 (6d)

0x36 (54d)

0x00 (0d)

0x0A (10d)

0x0B (11d)

Board Voltage

Auto-set MY

Guard Time After

Baud Rate (Serial Data Rate)

RF Data Rate

Guard Time Before

Command Sequence Character

GPO2 Configuration

Number Base

Exit Command Mode

GPO1 Configuration

Command Mode Timeout

Received Signal Strength

Destination Address

Echo Off

Echo On

0x2CCCA – 0x5BFFA [read-only]

-

2 - (ATST-3) [x 100 msec]

0 - 8

0 - 1

0 – 0xFFFF [x 100 msec]

0x20 - 0x7F

0 - 2

0 - 2

-

0 - 4

2 – 0xFFFF [x 100 ms]

-

-

0x6E to 0x28 [read-only]

0 - 0xFFFF

Diagnostics

Networking & Security

Command Mode Options 2

Serial Interfacing

RF Interfacing

4

-

1

1

Command Mode Options 2

Command Mode Options 1

Serial Interfacing 1

Command Mode Options 1

Command Mode Options -

Serial Interfacing 1

Command Mode Options 2

Diagnostics

Networking & Security

2

2

Command Mode Options -

Command Mode Options -

-

-

0x0A (10d)

3

1

0x0A (10d)

0x2B [“+”] (43d)

2

-

-

-

0

1

-

0

0xC8 (200d)

ER

FH

FL

FS

FT

GD

HP

HT

HV

ID

0x0F (15d)

0x0D (13d)

0x07 (7d)

0x3E (62d)

0x24 (36d)

0x10 (16d)

0x11 (17d)

0x03 (3d)

-

0x27 (39d)

Receive Error Count

Force Wake-up Initializer

Software Flow Control

Forced Sync Time

Flow Control Threshold

Receive Good Count

Hopping Channel

Time before Wake-up Initializer

Hardware Version

Modem VID

KY

LH

0x3C (60d)

0x0C (12d)

AES Encryption Key

Wake-up Initializer Timer

MK 0x12 (18d) Address Mask

MT 0x3D

MY

NB

PK

PL

0x2A (42d)

0x23 (35d)

0x29 (41d)

0x3A (58d)

Source Address

Parity

Maximum RF Packet Size

TX Power Level

0 – 0xFFFF

-

0 - 1

1 – 0xFFFF [x 10 msec]

0 – DI Buffer size (bytes)

0 – 0xFFFF

0 - 9

0 – 0xFFFF [x 100 msec]

0 – 0xFFFF [read-only]

0 - 0x7FFF (user-settable)

0x8000 - 0xFFFF (factory-set)

Diagnostics

Sleep (Low Power)

Serial Interfacing

RF Interfacing

Serial Interfacing

Diagnostics

Networking & Security

Sleep (Low Power)

Diagnostics

Networking & Security

0 – (Any other 64-digit hex valid key) Networking & Security

0 – 0xFF [x 100 msec]

0 - 0xFFFF

– 0xFF

Sleep (Low Power)

Networking & Security

Networking & Security

0 - 0xFFFF

0 - 4

1 – 0x800 [Bytes]

0 - 4

Networking & Security 2

Serial Interfacing

RF Interfacing

RF Interfacing

1

2

2

2

1

2

2

-

2

2

2

1

2

1

1

2

1

0

-

0

0 varies

0

0

0xFFFF (65535d)

-

0x3332 (13106d)

0

1

0xFFFF (65535d)

0

0

0x800 (2048d)

4 [1 Watt]

TR

TT

TX

VL

PW

RB

RC

RE

RM

RN

RO

RP

RR

RT

SB

SH

SL

SM

ST

TP

VR

WA

0x14 (20d)

-

Firmware Version

Active Warning Numbers

WN -

WR 0x08

Warning Data

WS

0x1D (29d)

0x20 (32d)

-

0x0E (14d)

-

0x19 (25d)

0x21 (33d)

0x22 (34d)

0x18 (24d)

0x16 (22d)

0x37 (55d)

0x25 (37d)

0x26 (38d)

0x01 (1d)

0x02 (2d)

0x38 (56d)

0x1B (27d)

0x1A (26d)

0x3F (63d)

-

-

Pin Wake-up

Packetization Threshold

Ambient Power - All Channels

Delay Slots

Packetization Timeout

RSSI PWM Timer

Retries

GPI1 Configuration

Stop Bits

Serial Number High

Serial Number Low

Sleep Mode

Time before Sleep

Board Temperature

Delivery Failure Count

Streaming Limit

Transmit Only

Firmware Version - verbose

Sticky Warning Numbers

0 - 1

1 - Current value of PK

Ambient Power - Single Channel 0 – 0x31 [dBm, read-only]

Restore Defaults -

No parameter – 0x7D0

0 – 0xFF (slots)

0 – 0xFFFF [x UART character time] Serial Interfacing

0 – 0xFF [x 100 msec] Diagnostics

0 – 0xFF

0 - 2

0 - 1

0 – 0xFFFF [read-only]

0 - 2, 4 - 8; 3 reserved

(ATAT+3) – 0x7FFF [x 100 msec]

0 – 0x7F [read-only]

0 – 0xFFFF [read-only]

0 – 0xFFFF [0 = disabled]

0 - 1

Returns string

0 - 0xFFFF [read-only]

Returns string

Returns string

-

Returns string

Sleep (Low Power) 1

Serial Interfacing 2

Diagnostics

(Special)

Diagnostics

Networking & Security

Networking & Security

Serial Interfacing

Serial Interfacing

Diagnostics

Sleep (Low Power)

Sleep (Low Power)

Diagnostics

Diagnostics

Networking & Security

RF Interfacing

Diagnostics

Diagnostics

Diagnostics

Diagnostics

(Special)

Diagnostics

1

-

2

1

2

1

1

1

1

2

1

2

1

2

2

1

-

2

-

-

0x0A (10d)

0

0 varies varies

0

0x64 (100d)

-

0

0

0

-

-

-

-

- -

-

0

-

-

-

0

3

0x20 (32d)

-

(2048d)

Command

Category

# Bytes

Returned

Factory

Default

   © 2005 MaxStream, Inc. Confidential and Proprietary  23 

9XTend‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v1.2.4 

4.4. Command Descriptions

Commands in this section are listed alphabetically. Command categories are designated between the “< >” symbols that follow each command title. By default, XTend RF Modems expect numerical values in hexadecimal since the default value of the CF (Number Base) Parameter is

‘1’. Hexadecimal values are designated by the “0x” prefix and decimal values by the “d” suffix.

%V (Board Voltage) Command

<Diagnostics> %V Command is used to read the current voltage of the XTend Module circuit board.

Sample Output: 5.02 V (when ATCF = 0)

5051F (when ATCF = 1) *

5.02 (when ATCF = 2)

* When CF = 1 (default), a hex integer is shown that is equal to (voltage * 65536d).

AT Command: AT%V

Binary Command: 0x3B (59 decimal)

Parameter Range (read-only):

0x2CCCA – 0x5BFFA

(2.80 – 5.75 decimal)

Number of bytes returned: 4

AM (Auto-set MY) Command

<Networking & Security> AM Command is used to automatically set the MY (Source Address) parameter from the factory-set modem serial

AT Command: ATAM

Binary Command: 0x40 (64 decimal) number. The address is formed with bits 29, 28 and 13-0 of the serial number (in that order).

The value is displayed as a result of this command.

AT (Guard Time After) Command

<Command Mode Options> AT Command is used to set/read the time-of-silence that follows the command sequence character (CC Command). By default, 1 second must elapse before and after the command sequence character.

The default sequence used to enter the RF modem into AT Command Mode is as follows:

AT Command: ATAT

Binary Command: 0x05 (5 decimal)

Parameter Range: 2 – (ATST-3), up to 0x7FFC

[x milliseconds]

Default Parameter Value: 0x0A (10 decimal)

Number of bytes returned: 2

Related Commands: BT (Guard Time Before),

CC (Command Sequence Character)

• No characters sent for 1 second [BT (Guard

Time Before) Command]

• Send three plus characters “+++” [CC (Command Sequence Character) Command]

• No characters sent for 1 second [AT (Guard Time After) Command]

BD (Baud Rate) Command

<Serial Interfacing> BD Command is used to set/read the interface data rate (the rate at which serial data is sent to the modem from a host).

Newly modified serial data rates do not take effect until the modem exits Command Mode [refer to

CN (Exit Command Mode) and CT (Command

Mode Timeout) Commands].

The BR (RF Data Rate) Parameter is not affected by the BD Command.

Note: If the serial data rate is set to exceed the fixed RF data rate of the XTend Modem, flow control may need to be implemented. Refer to the

Flow Control [p13] and CS (GPO1 Configuration)

Command [26] sections for more information.

AT Command: ATBD

Binary Command: 0x15 (21 decimal)

Parameter Range: 0 – 8

Parameter

Value

BAUD (bps)

Configuration

0 1200

1 2400

2 4800

3 9600

4 19200

5 38400

6 57600

7 115200

8 230400

Default Parameter Value: 3

Number of bytes returned: 1

   © 2005 MaxStream, Inc. Confidential and Proprietary  24 

9XTend‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v1.2.4 

BR (RF Data Rate) Command

<RF Interfacing> BR Command is used to set/read the RF data rate (rate that RF data is transmitted over-the-air) of the modem.

BT (Guard Time Before) Command

<Command Mode Options> BT Command is used to set/read the time-of-silence that precedes the command sequence character (CC Command) of the AT Command Mode Sequence.

Refer to the AT Command Mode section [p18] to

view the default AT Command Mode Sequence.

AT Command: ATBR

Binary Command: 0x39 (57 decimal)

Parameter Range: 0 – 1

Parameter

Value

BAUD (bps)

Configuration

0 9600

1 115200

Default Parameter Value: 1

Number of bytes returned: 1

AT Command: ATBT

Binary Command: 0x04 (4 decimal)

Parameter Range: 0 – 0xFFFF

100

Default Parameter Value: 0x0A (10 decimal)

Number of bytes returned: 2

Related Commands: AT (Guard Time After),

CC (Command Sequence Character)

CC (Command Sequence Character) Command

<Command Mode Options> CC Command is used to set/read the ASCII character used between

Guard Times of the AT Command Mode Sequence

(BT+ CC + AT). The AT Command Mode Sequence activates AT Command Mode (from Idle Mode).

[Refer to the BT (Guard Time Before) command to view the sequence used to enter the RF modem into AT Command Mode.

CD (GPO2 Configuration) Command

<Serial Interfacing> CD Command is used to select/read the behavior of the GPO2 line.

AT Command: ATCC

Binary Command: 0x13 (19 decimal)

Parameter Range: 0x20 – 0x7F

Default Parameter Value: 0x2B (ASCII “+” sign)

Number of bytes returned: 1

Related Commands: AT (Guard Time After),

BT (Guard Time Before)

AT Command: ATCD

Binary Command: 0x28 (40 decimal)

Parameter Range: 0 – 2

Parameter

Value

Configuration

Default Parameter Value: 2 high low

Number of bytes returned: 1

CF (Number Base) Command

<Command Mode Options> CF command is used to set/read command formatting setting.

The following commands are always entered and read in hex, no matter the CF setting:

• VR (Firmware Version)

• HV (Hardware Version)

• KY (AES Encryption Key)

AT Command: ATCF

Binary Command: 0x1F (31 decimal)

Parameter Range: 0 – 2

Parameter

Value

Configuration

0

1

Commands utilize default number base; decimal commands may output units

All commands are forced to unsigned, unit-less hex

Commands utilize default

2 number base; no units output

Default Parameter Value: 1

Number of bytes returned: 1

   © 2005 MaxStream, Inc. Confidential and Proprietary  25 

9XTend‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v1.2.4 

CN (Exit Command Mode) Command

<Command Mode Options> CN Command is used to explicitly exit AT Command Mode.

AT Command: ATCN

Binary Command: 0x09 (9 decimal)

CS (GP01 Configuration) Command

<Serial Interfacing> CS Command is used to select the behavior of the GP01 pin. This output can provide RS-232 flow control, control the TX enable signal (for RS-485 or RS-422 operations), or set the default level for the I/O line passing function.

(Clear-toBy default, GP01 provides RS-232

Send) flow control.

AT Command: ATCS

Binary Command: 0x1F (31 decimal)

Parameter Range: 0 – 4

Parameter

Value

Configuration

1 RS-485 TX enable low

2 high

3 RS-485 TX enable high

4 low

Default Parameter Value: 0

Number of bytes returned: 1

Related Commands: RT (GPI1 Configuration),

TO (GP01 Timeout)

CT (Command Mode Timeout) Command

<Command Mode Options> CT Command is used to set the amount of time before AT Command

Mode terminates automatically. After a CT time of inactivity, the modem exits AT Command Mode and returns to Idle Mode. AT Command Mode can also be exited manually by issuing the CN (Exit

AT Command Mode) Command.

AT Command: ATCT

Binary Command: 0x06 (6 decimal)

Parameter Range: 2 – 0xFFFF [x 100 ms]

Default Parameter Value: 0xC8 (200d)

Number of bytes returned: 2

Related Command: CN (Exit Command Mode)

DB (Received Signal Strength) Command

<Diagnostics> DB Command is used to read the receive signal strength (in decibels relative to milliWatts) of the last received packet. This

AT Command: ATDB

Binary Command: 0x36 (54 decimal) parameter is useful in determining range characteristics of XTend Modems under various conditions.

Parameter Range (read-only):

0x6E – 0x28

(-110 to -40 Decimal)

Number of bytes returned: 2

In default mode, this command shows the power level in signed decimal format, with the units

Related Command: CN (Exit Command Mode)

(dBm). If CF is set to 1, the magnitude of the value is presented in unsigned hex. If CF is set to

2, the value is presented in decimal, but without the units.

Sample Output: -88 dBm

58

(when ATCF = 0)

(when ATCF = 1)

(when 2)

NOTE: If the DB register is read before the modem has received an RF packet, the modem will return a value of 0x8000 (which means no packets have yet been received).

   © 2005 MaxStream, Inc. Confidential and Proprietary  26 

9XTend‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v1.2.4 

DT (Destination Address) Command

<Networking & Security> DT Command is used to set/read the networking address of an XTend

Modem. XTend Modems uses three network layers

–Vendor Identification Number (ATID), Channels

(ATHP), and Destination Addresses (ATDT). DT

Command assigns an address to a modem that enables it to communicate only with other

AT Command: ATDT

Binary Command: 0x00

Parameter Range: 0 – 0xFFFF

Default Parameter Value: 0

Number of bytes returned: 2

Related Commands: HP (Hopping Channel),

ID (Modem VID), MK (Address Mask), MY

(Source Address) modems having the same addresses. All modems that share the same DT parameter can communicate freely with each other.

Modems in the same network with a different destination address (than that of the transmitter) will listen to all transmissions to stay synchronized, but will not send any of the data out their serial ports.

E0 (Echo Off) Command

<Command Mode Options> E0 Command turns off character echo in AT Command Mode. By default, echo is off.

AT Command: ATE0

Binary Command: 0x0A (10 decimal)

E1 (Echo On) Command

<Command Mode Options> E1 Command turns on the character echo in AT Command Mode. Each typed character will be echoed back to the terminal when ATE1 is active. E0 is the default.

AT Command: ATE1

Binary Command: 0x0B (11 decimal)

ER (Receive Error Count) Command

<Diagnostics> Set/Read the number of receiveerrors. The error count records the number of packets partially received then aborted on a reception error. This value returns to 0 after a reset and is not non-volatile (Value does not persist in the modem’s memory after a power-up sequence). Once the Receive Error Count reaches

AT Command: ATER

Binary Command: 0x0F (15 decimal)

Parameter Range: 0 – 0xFFFF

Default Parameter Value: 0

Number of bytes returned: 2

Related Commands: GD (Receive Good Count) its maximum value (up to 0xFFFF), it remains at its maximum count value until the maximum count value is explicitly changed or the modem is reset.

The ER parameter is not reset by pin, serial port or cyclic sleep modes.

FH (Force Wake-up Initializer) Command

<Sleep (Low Power)> FH Command is used to force a Wake-up Initializer to be sent on the next transmission. WR (Write) Command does not need to be issued with FH Command.

AT Command: ATFH

Binary Command: 0x0D (13 decimal)

Use only with cyclic sleep modes active on remote modems.

FL (Software Flow Control) Command

<Serial Interfacing> FL Command is used to configure software flow control. Hardware flow control is implemented with the XTend Modem as the GP01 pin ( ), which regulates when serial data can be transferred to the modem.

FL Command can be used to allow software flow control to also be enabled. XON character used is

0x11 (17 decimal). XOFF character used is 0x13

(19 decimal).

AT Command: ATFL

Binary Command: 0x07 (7 decimal)

Parameter Range: 0 – 1

Parameter

Value

Configuration

0

1

Disable software flow control

Enable software flow control

Default Parameter Value: 0

Number of bytes returned: 1

   © 2005 MaxStream, Inc. Confidential and Proprietary  27 

9XTend‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v1.2.4 

FS (Forced Synch Time) Command

<RF Interfacing> FS Command only applies to streaming data. Normally, only the first packet of a continuous stream has the full RF initializer. The modems then remain synchronized for subsequent packets of the stream. This parameter can be used to periodically force an RF initializer during

AT Command: ATFS

Binary Command: 0x3E (62 decimal)

Parameter Range: 0 – 0xFFFF

[x

Default Parameter Value: 0

Number of bytes returned: 2 such streaming. Any break in UART character reception long enough to drain the DI Buffer (UART receive buffer) and cause a pause in RF data transmission will also cause an RF initializer to be inserted on the next transmission.

FT (Flow Control Threshold) Command

<Serial Interfacing> Set/Read the flow control threshold. When FT bytes have accumulated in the DI buffer, is de-asserted or the XOFF software flow control character is transmitted.

AT Command: ATFT

Binary Command: 0x24 (36 decimal)

Parameter Range: 0 – (Receive buffer size minus 0x11 bytes)

Default Parameter Value: DO Buffer size minus 0x11 (decimal 17)

Number of bytes returned: 2

GD (Receive Good Count) Command

<Diagnostics> Set/Read the count of good received RF packets. Parameter value is reset to 0 after every reset and is not non-volatile (Value does not persist in the modem’s memory after a power-up sequence). Once the “Receive Good

Count” reaches its maximum value (up to

AT Command: ATGD

Binary Command: 0x10 (16 decimal)

Parameter Range: 0 – 0xFFFF

Default Parameter Value: 0

Number of bytes returned: 2

Related Commands: ER (Receive Error Count)

0xFFFF), it remains at its maximum count value until the maximum count value is manually changed or the modem is reset.

The GD parameter is not reset by pin, serial port or cyclic sleep modes.

HP (Hopping Channel) Command

<Networking & Security> HP Command is used to set/read the modem’s hopping channel number. A channel is one of three layers of addressing available to the XTend Modem.

In order for modems to communicate with each other, the modems must have the same channel

AT Command: ATHP

Binary Command: 0x11 (17 decimal)

Parameter Range: 0 – 9

Default Parameter Value: 0

Number of bytes returned: 1

Related Commands: ID (Modem VID), DT

(Destination Address), MK (Address Mask) number since each channel uses a different hopping sequence. Different channels can be used to prevent modems in one network from listening to transmissions of another.

   © 2005 MaxStream, Inc. Confidential and Proprietary  28 

9XTend‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v1.2.4 

HT (Time before Wake-up Initializer) Command

<Sleep (Low Power)> Set/read time of inactivity

(no serial or RF data is sent or received) before a wake-up initializer is sent by a TX modem. HT should be set shorter than inactivity timeout [ST

Command] time of any RX modems operating in

Cyclic Sleep (SM=4-8). The wake-up initializer sent by the TX modem instructs all RX modems to remain awake to receive RF data.

AT Command: ATHT

Binary Command: 0x03 (3 decimal)

Parameter Range: 0 – 0xFFFF

[x milliseconds]

Default Parameter Value: 0xFFFF (wake-up initializer will not be sent)

Number of bytes returned: 2

Related Commands: LH (Wake-up Initializer

Timer), SM (Sleep Mode), ST (Time before

Sleep)

From the RX modem perspective: After HT time elapses and the inactivity timeout [ST Command] is met, the RX modem goes into cyclic sleep. In cyclic sleep, the RX modem wakes once per sleep interval [SM Command] to check for a wake-up initializer. When a wake-up initializer is detected, the modem stays awake to receive data. The wake-up initializer must be longer than the cyclic sleep interval to ensure that sleeping modems detect incoming data.

When HT time elapses, the TX modem knows it needs to send a wake-up Initializer for all RX modems to remain awake and receive the next transmission.

HV (Hardware Version) Command

<Diagnostics> HV Command is used to read the hardware version of the modem.

AT Command: ATHV

Parameter Range (read-only): 0 – 0xFFFF

Default Parameter Value: 0x14FF (5375d)

Number of bytes returned: 2

ID (Modem VID) Command

<Networking & Security> ID Command is used to set/read the VID (Vendor Identification Number) of the modem. Modems must have matching VIDs in order to communicate.

AT Command: ATID

Binary Command: 0x27 (39 decimal)

Parameter Range:

0 – 0x7FFF (user-settable)

0x8000 – 0xFFFF (factory-set)

Default Parameter Value: 0x3332 (13106d)

Number of bytes returned: 2

KY (AES Encryption Key) Command

<Networking & Security> KY Command is used to set the 256-bit AES (Advanced Encryption

Standard) key for encryption/decryption of data.

Once set, the key cannot be read out of the modem by any means. The entire payload of the packet is encrypted using the key and the CRC is computed across the ciphertext. When encryption

AT Command: ATKY

Binary Command: 0x3C (60 decimal)

Parameter Range:

0–(any other 64-digit hex valid key)

Default Parameter Value: 0 (disabled)

Number of bytes returned: 2

Number Base: Always Hexadecimal is turned on, each packet carries an additional 16 bytes to convey the random CBC Initialization

Vector (IV) to the receiver(s).

A modem with the wrong key (or no key) will still receive encrypted data, but the resultant data driven out the serial port will be meaningless. Likewise, a modem with a key will still receive unencrypted data sent from a modem without a key, but the output will be meaningless.

Because CBC mode is utilized, repetitive data appears different in different transmissions due to the randomly-generated IV.

   © 2005 MaxStream, Inc. Confidential and Proprietary  29 

9XTend‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v1.2.4 

LH (Wake-up Initializer Timer) Command

<Sleep (Low Power)> LH Command is used to set/read the duration of time for which the wakeup initializer is sent. When receiving modems are put into Cyclic Sleep Mode, they power-down after a period of inactivity [specified by ST (Time before

Sleep) Command] and will periodically awaken and listen for transmitted data. In order for the receiving modems to remain awake, they must detect ~35ms of the wake-up initializer.

AT Command: ATLH

Binary Command: 0x0C (12 decimal)

Parameter Range: 0 – 0xFF

[x

Default Parameter Value: 1

Number of bytes returned: 1

Related Commands: HT (Time before Wakeup Initializer), SM (Sleep Mode), ST (Time before Sleep) milliseconds]

LH Command must be used whenever a receiver is operating in Cyclic Sleep Mode. This lengthens the Wake-up Initializer to a specific amount of time (in tenths of a second). The Wake-up

Initializer Time must be longer than the cyclic sleep time that is determined by SM (Sleep Mode)

Command. If the wake-up initializer time were less than the Cyclic Sleep interval, the connection would be at risk of missing the wake-up initializer transmission.

Refer to Figures 4-03 & 4-04 of the SM Command description to view diagrams of correct and incorrect configurations. The images help visualize the importance that the value of LH be greater than the value of SM.

MK (Address Mask) Command

<Networking & Security> MK Command is used to set/read the “Address Mask”. All data packets contain the Destination Address of the transmitting modem.

When an RF data packet is received, the transmitter’s Destination Address is logically

“ANDed” (bitwise) with the Address Mask of the receiver. The resulting value must match the

Destination Address or the Address Mask of the receiver for the packet to be received and sent

AT Command: ATMK

Binary Command: 0x12 (18 decimal)

Parameter Range: 0 – 0xFFFF

Default Parameter Value: 0xFFFF (65535d)

Destination address (DT parameter) of the transmitting modem must exactly match the destination address of the receiving modem.

Number of bytes returned: 2

Related Commands: DT (Destination

Address), HP (Hopping Channel), ID (Modem

VID), MY (Source Address) out the modem’s DO serial port. If the “ANDed” value does not match either the Destination

Address or the Address Mask of the receiver, the packet is discarded. (All “0” values are treated as “irrelevant” values and are ignored.)

MT (Multi-Transmit) Command

<Networking & Security> MT packets do not request an acknowledgement from receiving modem(s). MT takes precedence over RR, so if both MT and RR are non-zero, then MT+1 packets will be sent, with no ACK requests.

When a receiving modem receives a packet with remaining forced retransmissions, it calculates the length of the packet and inhibits transmission for

AT Command: ATMT

Binary Command: 0x3D (61 decimal)

Parameter Range: 0 – 0xFF

Default Parameter Value: 0 (no forced retransmissions)

Number of bytes returned: 1

Related Commands: Networking (DT, MK,

MY, RN, TT), Serial Interfacing (BR, PK, RB,

RO), RF Interfacing (FS) the amount of time required for all retransmissions. Thereafter, a random number of delay slots are inserted between 0 and RN before transmission is allowed from the receiving modem(s). This prevents all listening modems from transmitting at once upon conclusion of a multiple transmission event (when RN > 0).

Comment: Actual number of forced transmissions is the parameter value plus one. For example, if MT=1, two transmissions of each packet will be sent.

   © 2005 MaxStream, Inc. Confidential and Proprietary  30 

9XTend‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v1.2.4 

MY (Source Address) Command

<Networking & Security> Set/Read the source address of the modem.

NB (Parity) Command

<Serial Interfacing> Select/Read parity settings for UART communications.

AT Command: ATMY

Binary Command: 0x2A (42 decimal)

Parameter Range: 0 – 0xFFFF

Default Parameter Value: 0xFFFF (Disabled,

DT (Destination Address) parameter serves as both source and destination address.)

Number of bytes returned: 2

Related Commands: DT (Destination

Address), HP (Hopping Channel), ID (Modem

VID), MK (Address Mask)

AT Command: ATNB

Binary Command: 0x23 (35 decimal)

Parameter Range: 0 – 4

Parameter

Value

0

Configuration

8-bit (no parity or

7-bit (any parity) even

2 8-bit

3 8-bit

4 8-bit

Default Parameter Value: 0

Number of bytes returned: 1 odd mark

PK (Maximum RF Packet Size) Command

<RF Interfacing> PK Command is used to set/read the maximum size of RF packets. The maximum packet size can be used along with

RB/RO to implicitly set the channel dwell time.

If PK is set above 256 and BR is subsequently changed to 0, then PK will automatically be lowered to 256 and a warning will be raised (see

BR (RF Data Rate) and WN (Warning Data)

Commands for details).

AT Command: ATPK

Binary Command: 0x29 (41 decimal)

Parameter Range: 0 – 0x800 [Bytes]

Default Parameter Value: 0x800*

(2048 decimal)

Number of bytes returned: 2

Related Commands: BR (RF Data Rate) RB

(Packetization Threshold), RO (Packetization

Timeout), WN (Warning Data)

Changes to this parameter may have a secondary effect on the RB (Packet Control Characters)

Parameter. RB must always be less than or equal to PK. If PK is changed to a value less than the current value of RB, RB is automatically lowered to be equal to PK.

* When BR = 0, the maximum PK value is 0x100 (256d). When BR = 1, the maximum PK value is 0x800 (2048d). 

PL (Power Level) Command

<RF Interfacing> PL Command is used to set/read the power level at which the modem transmits.

AT Command: ATPL

Binary Command: 0x3A (58 decimal)

Parameter Range: 0 – 4

Parameter

Value

Configuration

Default Parameter Value: 4

Number of bytes returned: 1 mW

3 500

4 mW mW

1000 mW (1 Watt)

   © 2005 MaxStream, Inc. Confidential and Proprietary  31 

9XTend‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v1.2.4 

PW (Pin Wake-up) Command

<Sleep (Low Power)> Under normal operation, a modem in Cyclic Sleep Mode cycles from an active

AT Command: ATPW

Binary Command: 0x1D (29 decimal) state to a low-power state at regular intervals until data is ready to be received. If the PW

Parameter is set to 1, the SLEEP Pin can be used to awaken the modem from Cyclic Sleep. If the

SLEEP Pin is de-asserted (low), the modem will be fully operational and will not go into Cyclic Sleep.

Once SLEEP is asserted, the modem will remain active for the period of time specified by ST (Time

Parameter Range: 0 – 1

Parameter

Value

Configuration

0 Disabled

1 Enabled

Default Parameter Value: 0

Number of bytes returned: 1

Related Commands: SM (Sleep Mode), ST

(Time before Sleep) before Sleep) Command, and will return to Cyclic

Sleep Mode (if no data is ready to be transmitted). PW Command is only valid if Cyclic Sleep has been enabled.

RB (Packetization Threshold) Command

<Serial Interfacing> RF transmission will commence when data is in the DI Buffer and either of the following criteria are met:

RO character times of silence on the UART receive lines (ignored if RO = 0)

RB characters have been received by the UART

(ignored if RB = 0)

AT Command: ATRB

Binary Command: 0x20 (32 decimal)

Parameter Range: 0 – Current value of PK

Parameter (up to 0x800 Bytes)

Default Parameter Value: 0x800

Number of bytes returned: 2

Related Commands: BR (RF Data Rate), PK (RF

Packet Size), RO (Packetization Timeout)

If PK is lowered below the value of RB, RB is automatically lowered to match PK.

Note: RB and RO criteria only apply to the first packet of a multi-packet transmission. If data remains in the DI Buffer after the first packet, transmissions will continue in streaming manner until there is no data left in the DI Buffer (UART receive buffer).

RC (Ambient Power – Single Channel) Command

<Diagnostics> RC Command is used to examine and report the power level on a given channel.

Sample output: -78 dBm [when CF = 0]

4e [when CF = 1]

-78 [when CF = 2]

AT Command: ATRC

Parameter Range (read-only): 0 – 0x31 [dBm]

Number of bytes returned: 1

Related Commands: RM (Ambient Power – All channels)

RE (Restore Defaults) Command

<Diagnostics> RE Command is used to restore all configurable parameters to factory default settings. However, RE Command will not write the

AT Command: ATRE

Binary Command: 0x0E (14 decimal) default values to non-volatile (persistent) memory. Unless the WR (Write) Command is issued after the RE command, the restored default settings will not be saved in the event of modem reset or power-down.

RM (Ambient Power – All Channels) Command

<Diagnostics> RM Command is used to examine and report the power levels on all channels. If no parameter is given, then the channels will be scanned once. If a parameter is given, the channels will be repeatedly scanned for that

AT Command: ATRM

Parameter Range: no parameter – 0x7D0

(2000d)

Number of bytes returned: 2

Related Commands: RC (Ambient Power –

Single channel) number of seconds (up to 2000d), and the maximum power level seen for each channel is reported (i.e. peak hold).

   © 2005 MaxStream, Inc. Confidential and Proprietary  32 

9XTend‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v1.2.4 

RM Command (continued)

A graphical spectrum analyzer application can be implemented by repeatedly calling ATRM with no arguments and reading the resultant 50 power levels (easiest to do when CF = 1 or 2).

Sample output [when CF = 0]: Ch 0: -100 dBm

Ch 1: -103 dBm

...

Ch 49: -99 dBm

Sample output [when CF = 1]: 64

67

...

63

Sample output [when CF = 2]: -100

-103

-99

RN (Delay Slots) Command

<Networking & Security> RN Command is used to set/read the time delay that the transmitting modem inserts before attempting to resend a packet. If the transmitting modem fails to receive an acknowledgement after sending a packet, it inserts a random number of delay slots (ranging from 0 to (RN minus 1)) before attempting to resend the packet. Each delay slot lasts for a period of 38 ms.

AT Command: ATRN

Binary Command: 0x19 (25 decimal)

Parameter Range: 0 – 0xFF [38 ms slots]

Default Parameter Value: 0 (no delay slots inserted)

Number of bytes returned: 1

Related Commands: RR (Retries), TT

(Streaming Limit)

If two modems attempt to transmit at the same time, the random time delay after packet failure allows only one modem to transmit the packet successfully; while the other modem waits until the channel available for RF transmission.

RN Command is only applicable if retries have been enabled [RR (Retries) Command] or if forced delays will be inserted into a transmission [TT (Streaming Limit) Command].

RO (Packetization Timeout) Command

<Serial Interfacing> RO Command is used to set/read the Packetization Timeout setting. RF transmission commences when data is in the DI buffer and either of the following criteria are met:

RO character times of silence on the UART receive lines (ignored if RO = 0)

AT Command: ATRO

Binary Command: 0x21 (33 decimal)

Parameter Range: 0 – 0xFFFF

[ x UART character times ]

Default Parameter Value: 0x03 (3 decimal)

Number of bytes returned: 2

Related Commands: RB (Packetization

Threshold)

RB characters have been received by the UART

(ignored if (RB = 0)

RB and RO criteria only apply to the first packet of a multi-packet transmission. If data remains in the DI Buffer (UART receive) after the first packet, transmissions will continue in streaming manner until there is no data left in the DI Buffer (UART receive).

   © 2005 MaxStream, Inc. Confidential and Proprietary  33 

9XTend‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v1.2.4 

RO Command (continued)

When RO is the transmission-beginning criteria: The actual time between the reception of the last character from the UART and the beginning of RF transmission will be at least 800 µsec longer than the actual RO time to allow for transmission setup. Additionally, it is subject to 100 - 200

µsec of additional uncertainty, which could be significant for small values of RO at high UART bit rates.

The RO timer calculates the correct UART character time (10, 11, or 12 bits) based on the following criteria:

• 1 start bit

• 8 data bits

• 0 or 1 parity bit (as set by ATNB)

• 1 or 2 stop bits (as set by ATSB)

RP (RSSI PWM Timer) Command

RP Command is used to enable a PWM (“Pulse

Width Modulation”). The pin is calibrated to show the difference between received signal strength and the sensitivity level of the modem. PWM pulses vary from zero to 95 percent. Zero percent means the received RF signal is at or below the

AT Command: ATRP

Binary Command: 0x22 (34 decimal)

Parameter Range: 0 - 0xFF

[x

Default Parameter Value: 0x20 (32 decimal)

Number of bytes returned: 1 published sensitivity level of the modem. The following table shows dB levels above sensitivity and PWM values:

The total time period of the PWM output is 8.32 ms. PWM output consists of 40 steps and therefore the minimum step size is 0.208 ms. dBm above Sensitivity

10 dBm

20 dBm

30 dBm

PWM percentage

(high period / total period)

20%

35%

50%

A non-zero value defines the time that PWM output is active with the RSSI value of the last received RF packet. After the set time when no RF packets are received, PWM output is set low (0 percent PWM) until another RF packet is received. PWM output is also set low at power-up. A parameter value of 0xFF permanently enables PWM output and always reflects the value of the last received RF packet.

Pin 11 of the encased OEM RF module is shared between PWM output and Config input. When the modem is powered, the Config pin is an input. During the power-up sequence, if RP parameter is a non-zero value, the Config pin is configured as an output and set low until the first RF packet is received. With a non-zero RP parameter, the Config pin is an input for RP ms after power up.

RR (Retries) Command

<Networking & Security> RR Command is used to set/read the number of retries that can be sent for a given RF packet. When RR Command is enabled (non-zero value) and when MT Command equals zero, RF packet acknowledgements and retries are enabled.

AT Command: ATRR

Binary Command: 0x18 (24 decimal)

Parameter Range: 0 – 0xFF

Default Parameter Value: 0x0A (10 decimal)

Number of bytes returned: 1

After transmitting a packet, the transmitting modem waits to receive an acknowledgement from a receiving modem. If the acknowledgement is not received in the period of time specified by RN

(Delay Slots) Command, the original packet is transmitted again. The RF packet is transmitted repeatedly until an acknowledgement is received or until the packet is sent RR times.

   © 2005 MaxStream, Inc. Confidential and Proprietary  34 

9XTend‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v1.2.4 

RT (GPI1 Configuration) Command

RT Command is used to set/read the behavior of the GPI1 pin. The pin can be configured to enable binary programming or flow control.

SB (Stop Bits) Command

<Serial Interfacing> SB Command is used to set/read the number of stop bits in the data packets.

SH (Serial Number High) Command

<Diagnostics> SH Command is used to set/read the serial number high word of the modem.

SL (Serial Number Low) Command

<Diagnostics> SL Command is used to set/read the serial number low word of the modem.

AT Command: ATRT

Binary Command: 0x16 (22 decimal)

Parameter Range: 0 – 2

Parameter

Value

Configuration

0 disabled

1

Enable Binary

Default Parameter Value: 0

Programming

Flow Control

Number of bytes returned: 1

AT Command: ATSB

Binary Command: 0x37 (55 decimal)

Parameter Range: 0 – 1

Parameter

Value

0

1

Configuration

1 stop bit

2 stop bits

Default Parameter Value: 0

Number of bytes returned: 1

AT Command: ATSH

Binary Command: 0x25 (37 decimal)

Parameter Range (read-only): 0 – 0xFFFF

Number of bytes returned: 2

Related Commands: SL (Serial Number Low)

AT Command: ATSL

Binary Command: 0x26 (38 decimal)

Parameter Range (read-only): 0 – 0xFFFF

Number of bytes returned: 2

Related Commands: SH (Serial Number High)

   © 2005 MaxStream, Inc. Confidential and Proprietary  35 

9XTend‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v1.2.4 

SM (Sleep Mode) Command

<Sleep Mode (Low Power)> SM Command is used to set/read the modem’s Sleep Mode settings that configure the modem to run in states that require minimal power consumption.

Pin Sleep (SM = 1)

Next to Shutdown Mode, Pin Sleep requires the least amount of power. In order to achieve this state, SLEEP must be asserted (high). The modem remains in Pin Sleep until the SLEEP pin is deasserted.

After enabling Pin Sleep (SM=1), GPI2 controls whether the XTend Modem is active or in Sleep

Mode. When GPI2 is de-asserted (low), the modem is fully operational. When GPI2 is asserted

(high), the modem transitions to Sleep Mode and remains in its lowest power-consuming state until the Sleep pin is de-asserted. GPI2 is only active if the modem is setup to operate in this mode; otherwise the pin is ignored.

Once in Pin Sleep Mode, GP01 ( ) is deasserted (high), indicating that data should not be sent to the modem. PWR is also de-asserted (low) when the modem is in Pin Sleep Mode.

AT Command: ATSM

Binary Command: 0x01

Parameter Range: 0 – 8

Parameter

Value

0 Disabled

1 Pin

2

4

5

6

7

Configuration

Sleep

Serial Port Sleep

3 reserved

Cyclic 1.0 second sleep

(Modem wakes every 1.0 second)

Cyclic 2.0 second sleep

Cyclic 4.0 second sleep

Cyclic 8.0 second sleep

8 Cyclic 16.0 second sleep

Default Parameter Value: 0

Number of bytes returned: 1

Related Commands:

Pin Sleep – PC (Power-up Mode), PW (Pin

Wake-up)

Serial Port Sleep – ST (Time before Sleep)

Cyclic Sleep – ST (Time before Sleep), LH

(Wake-up Initializer Timer), HT (Time Before

Wake-up Initializer), PW (Pin Wake-up)

Note: The module will complete a transmission or reception before activating Pin Sleep.

Serial Port Sleep (SM = 2)

Serial Port Sleep is a Sleep Mode in which the XTend Modem runs in a low power state until serial data is detected on the DI pin.

When Serial Port Sleep is enabled, the modem goes into Sleep Mode after a user-defined period of inactivity (no transmitting or receiving of data). This period of time is determined by ST (Time before Sleep) Command. Once a character is received through the DI pin, the modem returns to

Idle Mode and is fully operational.

Cyclic Sleep (SM = 4-8)

Cyclic Sleep is the Sleep Mode in which the XTend Modem enters into a low-power state and awakens periodically to determine if any transmissions are being sent. Cyclic sleep settings wake the modem after the amount of time designated by the associated SM parameter values. If the modem detects a wake-up initializer during the time it is awake, the modem synchronizes with the transmitting modem and starts receiving data after the wake-up initializer runs its duration.

Otherwise, the modem returns to Sleep Mode and continues to cycle in and out of activity until a wake-up initializer is detected. If a Cyclic Sleep setting is chosen, the ST, LH and HT parameters must also be set as described in the “Sleep Mode” section of this manual.

When Cyclic Sleep settings are enabled, the XTend Modem goes into Sleep Mode after a userdefined period of inactivity (no transmission or reception on the RF channel). The user-defined period is determined by ST (Time before Sleep) Command.

While the modem is in Cyclic Sleep Mode, GP01 ( ) is de-asserted (high) to indicate that data should not be sent to the modem during this time. When the modem awakens to listen for data,

GP01 is asserted and any data received on the DI Pin is transmitted. The PWR pin is also deasserted (low) when the modem is in Cyclic Sleep Mode.

   © 2005 MaxStream, Inc. Confidential and Proprietary  36 

9XTend‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v1.2.4 

SM Command (continued)

The modem remains in Sleep Mode for a user-defined period of time ranging from 0.5 seconds to

16 seconds (SM Parameters 3 through 8). After this interval of time, the modem returns to Idle

Mode and listens for a valid data packet for 100 ms. If the modem does not detect valid data (on any frequency), the modem returns to Sleep Mode. If valid data is detected, the modem transitions into Receive Mode and receives incoming RF packets. The modem then returns to

Sleep Mode after a Period of inactivity that is determined by ST “Time before Sleep” Command.

The modem can also be configured to wake from cyclic sleep when GPI2 (SLEEP) is de-asserted

(low). To configure a modem to operate in this manner, PW (Pin Wake-up) Command must be issued. Once GPI2 is de-asserted, the modem is forced into Idle Mode and can begin transmitting or receiving data. It remains active until no data is detected for the period of time specified by the ST Command, at which point it resumes its low-power cyclic state.

Note: The cyclic interval time defined by SM (Sleep Mode) Command must be shorter than the interval time defined by LH (Wake-up Initializer Timer).

For example: If SM=4 (Cyclic 1.0 second sleep), the LH Parameter should equal 0xB (“1.1” seconds).

With these parameters set, there is no risk of the receiving modem being asleep for the duration of wake-up initializer transmission. “Cyclic Scanning” explains in further detail the relationship between

“Cyclic Sleep” and “Wake-up Initializer Timer”

Cyclic Scanning. Each RF transmission consists of an RF Initializer and payload. The wake-up initializer contains initialization information and all receiving modems must wake during the wake-up initializer portion of data transmission in order to be synchronized with the transmitting modem and receive the data.

 

 

 

 

 

 

 

 

 

Figure 4‐03. Correct Configuration (LH > SM):  

Length of the wake‐up initializer exceeds the time interval of Cyclic Sleep. The receiver is guaranteed to detect  the wake‐up initializer and receive the accompanying payload data. 

 

 

Figure 4‐04. Incorrect Configuration (LH < SM): 

Length of wake‐up initializer is shorter than the time interval of Cyclic Sleep. This configuration is vulnerable  to the receiver waking and missing the wake‐up initializer (and therefore also the accompanying payload data). 

   © 2005 MaxStream, Inc. Confidential and Proprietary  37 

9XTend‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v1.2.4 

ST (Time before Sleep) Command

<Sleep Mode (Low Power)> ST Command is used to set/read the period of time (milliseconds) in which the modem remains inactive before entering Sleep Mode.

For example, if the ST Parameter is set to 0x64

(100 decimal), the modem will enter into Sleep mode after 10 seconds of inactivity (no transmitting or receiving).

AT Command: ATST

Binary Command: 0x02 (2 decimal)

Parameter Range: (ATAT+3) – 0x7FFF

[x

Default Parameter Value: 0x64 (100 decimal)

Number of bytes returned: 2

Related Commands: SM (Sleep Mode), LH

(Wake-up Initializer Timer), HT (Time before

Wake-up Initializer)

This command can only be used if Cyclic Sleep or Serial Port Sleep Mode settings have been selected using SM (Sleep Mode) Command.

TP (Board Temperature) Command

<Diagnostics> TP Command is used to read the current temperature of the board.

Sample Output: 26 C [when ATCF = 0]

1A [when ATCF = 1]

26 [when ATCF = 2]

TX (Transmit Only) Command

<RF Interfacing> TX Command is used to set/read the transmit/receive behaviors of the modem. Setting a modem to TX-only may reduce latency because the transmitting modem will never be "stuck" receiving data from other modems.

AT Command: ATTP

Binary Command: 0x38 (56 decimal)

Parameter Range (read-only): 0– 0x7F

Number of bytes returned: 1

Related Commands: WN (Warning Data)

TR (Transmit Error Count) Command

<Diagnostics> TR Command is used to report the number of retransmit failures. This number is incremented each time a packet is not acknowledged within the number of retransmits specified by RR (Retries) Command. It therefore counts the number of packets that were not successfully received and were subsequently dropped.

AT Command: ATTR

Binary Command: 0x1B (27 decimal)

Parameter Range: 0 – 0xFFFF

Default Parameter Value: 0

Number of bytes returned: 2

Related Commands: RR (Retries)

TR Parameter is not non-volatile and will therefore be reset to zero when the modem is reset.

TT (Streaming Limit) Command

<Networking & Security> TT Command is used to set/read the limit on the number of bytes that can be sent out before a random delay is issued.

If a modem is sending a continuous stream of RF data, a delay is inserted which stops its transmission and allows other modems time to

AT Command: ATTT

Binary Command: 0x1A (26 decimal)

Parameter Range: 0 – 0xFFFF

Default Parameter Value: 0 (disabled)

Number of bytes returned: 2

Related Commands: RN (Delay Slots) transmit (once it sends TT bytes of data). Inserted random delay lasts between 1 & ‘RN + 1’ delay slots, where each delay slot lasts 38 ms.

TT command can be used to simulate full-duplex behavior.

AT Command: ATTX

Binary Command: 0x3F (63 decimal)

Parameter Range: 0 – 1

Parameter

Value

Configuration

1 TX

Default Parameter Value: 0

Number of bytes returned: 1

   © 2005 MaxStream, Inc. Confidential and Proprietary  38 

9XTend‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v1.2.4 

VL (Firmware Version - verbose) Command

<Diagnostics> VL Command is used to read the verbose firmware version of the XTend Modem.

Sample output: Firmware version 1.0, Jan 16

2005 10:46:57

AT Command: ATVL

Parameter Range: Returns string

Number of bytes returned: 2

VR (Firmware Version) Command

<Diagnostics> VR Command is used to read the firmware version of the XTend Modem.

AT Command: ATVR

Binary Command: 0x14 (20 decimal)

Parameter Range (read-only): 0 – 0xFFFF

Number of bytes returned: 2

WA (Active Warning Numbers) Command

<Diagnostics> WA Command reports the warning numbers of all active warnings - one warning number per line. No further information is shown and warning counts are not reset.

AT Command: ATWA

Parameter Range: Returns string – one warning number per line.

Sample Output (indicates warnings 1 and 3 are currently active): 1

3

OK

WN (Active Warning Numbers) Command

<Diagnostics> WN Command is used to report detailed data for all active and sticky warnings.

AT Command: ATWN

Parameter Range: Returns string

• Warning number & description

• Number of occurrences since the last WN or WS command

• Whether the warning is currently active

Warnings which are not currently active, and have not been active since the last WN or WS command, are not displayed. WN Command also resets all non-zero warning counts, except for warnings that are presently active, which are set to 1.

Sample output: Warning 1: Under-voltage

3 occurrences; presently active

Warning 4: Over-temperature

Warning Number Description

1

2

3

4

5

6

7

8

Under-voltage. This is caused if the supply voltage falls below the minimum threshold for the lowest power level (2.8 V). If/when the voltage rises above the threshold, the warning is deactivated. The module will not transmit below this voltage threshold.

Over-voltage. This is caused if the supply voltage exceeds 5.75 V. Transmission is not allowed while this warning is active.

Under-temperature. This is caused if the temperature sensed by the module is less than -40 C. The module does not artificially limit operation while this warning is active, but module functionality is not guaranteed.

Over-temperature. This is caused if the temperature sensed by the module is greater than 105 C. The module does not allow transmission nor reception while this warning is active. The warning is deactivated when the temperature falls to 100 C.

Power reduced. This is caused if the transmit power has to be reduced from the level programmed by PL Command due to insufficient supply voltage.

The 1 W power level requires 4.75 V or higher; 500 mW requires 3.0 V or higher; 100 mW, 10 mW and 1 mW require 2.8 V or higher.

Default calibration data in flash. This is caused if the module-specific power calibration data is either not present or is invalid, or if none of the parameters have been modified from their default values. Power levels may be incorrect.

Default configuration parameters in flash. This is caused if the user-modifiable parameters (i.e. those stored by a 'WR' command) in flash are all the compiled-in default values. This is caused if the user configuration is found to be not present or invalid at power-up and there is no user custom configuration, or if no user-modifiable parameters have been modified from the compiled-in defaults. Note that modification of one or more parameters without the subsequent ATWR to commit the changes to flash will not deactivate this warning, since it reflects the status of the parameters in flash.

Note as well that this warning does not reflect usage of the custom configuration defaults, only usage of the compiled-in defaults.

Default factory configuration parameters in flash. This is caused if the factory parameters in flash are all the default values. This is caused if the factory configuration is found to be not present or invalid at power-up, or if no factory parameters have been modified.

   © 2005 MaxStream, Inc. Confidential and Proprietary  39 

9XTend‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v1.2.4 

WR (Write) Command

<(Special)> WR Command writes configurable parameters to the modem’s non-volatile memory

AT Command: ATWR

Binary Command: 0x08

(Parameter values remain in the modem’s memory until overwritten by future use of WR Command).

If changes are made without writing them to non-volatile memory, the modem reverts back to previously saved parameters the next time the modem is powered-on.

WS (Sticky Warning Numbers) Command

<Diagnostics> WS Command reports the warning numbers of all warnings which have been active since the last use of WS or WN command, including any warnings which are currently active.

No further information is shown.

AT Command: ATWS

Parameter Range (read-only): 1 – 8

Number of bytes returned: 1

This command also resets all non-zero warning counts, except for warnings that are presently active, which are set to 1.

   © 2005 MaxStream, Inc. Confidential and Proprietary  40 

9XTend‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v1.2.4 

5. RF Communication Modes 

The XTend RF Modem can be configured to operate in any of several RF communication modes:

• Streaming

• Acknowledged

• Multi-Transmit

The mode is defined by parameters stored in the transmitting modem [see table below].

Receiving modems automatically adapt to the correct mode on a per-packet basis, based on the contents of each received packet.

Table 5‐01. Mode in Relation to Transmitting Modem Parameter Values 

RF Communication Mode RR Parameter Value MT Parameter Value

Streaming 0 0

0

Multi-Transmit ignored >=1

5.1. Addressing Options

Transmissions can be addressed to a specific modem or group of modems using the DT

(Destination Address) and MK (Address Mask) commands. A receiving modem will only accept a packet if it determines the packet is addressed to it, either as a global or local packet. The receiving modem makes this determination by inspecting the destination address of the packet and comparing it to its own address and address mask [Figure 5-01].

Figure 5‐01. Address Recognition (@ RX Modem) 

The transmitting modem determines whether the packet is intended for a specific node (local address) or multiple nodes (global address) by comparing the packet’s destination address (DT) and its own address mask (MK) [Figure 5-02]. It is assumed that the address masks on the transmitting modem and receiving modem have been programmed to the same value for proper operation in each RF Communication Mode.

Figure 5‐02. Addressing Logic (@ TX Modem) 

   © 2005 MaxStream, Inc. Confidential and Proprietary  41 

9XTend‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v1.2.4 

5.2. Streaming Mode

Lowest latency and jitter

Streaming mode transmissions never acknowledged by receiving modem(s)

Required Parameter Values (TX Modem): RR (Retries) = 0

Related Commands: Networking (DT, MK, MY), Serial Interfacing (PK, RB, RO, TT)

Recommended Use: Mode is most appropriate for data that is more sensitive to latency and/or jitter than it is to occasional packet loss. For example: streaming audio or video.

5.2.1. Connection Sequence

Events up through the

‘ Transmit Packet’ process

a re common to all three

RF Communication

O ptions. Refer to the

T ransmit Mode section

[

p14] for more

information.

Figure 5‐03. Streaming Mode State Diagram 

When streaming data, RB and RO parameters are used only on the first packet. After transmission begins, the TX event will continue uninterrupted u ntil the DI buffer is empty or the streaming limit (TT

Command) is reached. As with the first packet, the payload of each subsequent packet includes up to the maximum packet size (PK Command).

The streaming limit is specified by the transmitting modem as the maximum number of bytes the transmitting modem can send in one transmission event. If the TT parameter is reached, the transmitting modem will force a random delay of 1 to RN delay slots (exactly 1 delay slot if RN=0).

Subsequent packets are sent without an RF initializer since receiving modems stay synchronized with the transmitting modem for the duration of the transmission event (from preceding packet information). However, due to interference, some receiving modems may lose data (and synchronization to the transmitting modem), particularly during long transmission events.

Once the transmitting modem has sent all pending data or has reached the TT limit, the transmission event ends. The transmitting modem will not transmit again for exactly RN delay slots if the local

(i.e. transmitting modem’s) RN parameter is set to a non-zero value. The receiving modem(s) will not transmit for a random number of delay slots between 0 and (RN-1) if the local (i.e. receiving modem’s) RN parameter is set to a non-zero value.

These delays are intended to lessen congestion following long bursts of packets from a single transmitting modem, during which several receiving modems may have become ready to transmit.

   © 2005 MaxStream, Inc. Confidential and Proprietary  42 

9XTend‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v1.2.4 

5.3. Acknowledged Mode

Attributes: Reliable delivery through positive acknowledgements for each packet

Throughput, latency and jitter vary depending on the quality of the channel and the strength of the signal.

Required Parameter Values (TX Modem): RR (Retries) >= 1

Related Commands: Networking (DT, MK, RR), Serial Interfacing (PK, RN, RO, RB, TT)

Recommended Use: Use for applications that require Reliable Delivery. If messages are smaller than 256 bytes, use RB and RO commands to align RF packets to application packets.

5.3.1. Connection Sequence

Events up through the ‘Transmit

P acket’ process are common to a ll three RF Communication

Options. Refer to the Transmit

M

ode section [p14] for more

in formation.

Figure 5‐04. Acknowledged Mode State Diagram 

After sending a packet while in acknowledged mode, the transmitting modem listens for an acknowledgement. If it receives the ACK, it will either move on to sending a subsequent packet (if more transmit data is pending), or will wait for exactly RN random d elay slots before allowing anothe r transmission (if no more data is pending to be transmit ted).

If the transmit ting modem does not receive the ACK within the allotted time, it will retransmit the packet with a new RF initializer following the ACK s lot.

There is no delay between the first ACK slot and the first retransmission. Subsequen t retransmissions incur a delay of a random number of delay slots, between 0 and RN. If RN is set to 0 on the transmitting modem , there are never any back-off delays between retransmission s.

Note that during back-off delays, the transmitting modem will go into Idle Mode and may receive

RF data. This can have the effect of increasing the back-off delay, as the radio cannot return to

RF transmit (or retransmit) mode as long as it is receiving RF data.

After r eceiving and acknowledging a packet, the receiving modem will move to the next frequency and listen for either a retransmission or new data, for a specific period of time.

Even if the transmitting modem has indicated that it has no more pending transmit data, it may have not received the previous ACK, and so may retransmit the packet, possibly with no delay after the

ACK slot. In this case, the receiving modem will always detect the immediate retransmission, which will hold off the communications channel and thereby reduce collisions. Receiving modem s acknowledge each retransmission they receive, but they only pass the first copy of a packet they receive out the UART.

   © 2005 MaxStream, Inc. Confidential and Proprietary  43 

9XTend‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v1.2.4 

RB and RO parameters are not applied to subsequent packets, meaning that once transmission has begun, it will continue uninterrupted until the DI buffer is empty or the streaming limit (TT) has been reached. As with the first packet, the payload of each subsequent packet includes up to the maximum packet size (PK), and the transmitting modem checks for more pending data near the end of each packet.

The streaming limit (TT) specifies the maximum number of bytes that the transmitting modem will send in one transmission event, which may consist of many packets and retries. If the TT parameter is reached, the transmitting modem will force a random delay of 1 to RN delay slots

(exactly 1 delay slot if RN is zero). Each packet is counted only once toward TT, no matter how many times the packet is retransmitted.

Subsequent packets in acknowledged mode are similar to those in streaming mode, with the addition of an acknowledgement between each packet, and the possibility of retransmissions.

Subsequent packets are sent without an RF initializer, as the receiving modems are already synchronized to the transmitting modem from the preceding packet(s) and they remain synchronized for the duration of the transmission event. Each retransmission of a packet includes an RF initializer.

Once the transmitting modem has sent all pending data or has reached the TT limit, the acknowledged transmission event is completed. The transmitting modem will not transmit again for exactly RN delay slots, if the local RN parameter is set to a nonzero value. The receiving modem will not transmit for a random number of delay slots between 0 and (RN-1), if the local

RN parameter is set to a nonzero value. These delays are intended to lessen congestion following long bursts of packets from a single transmitting modem, during which several receiving modems may have themselves become ready to transmit.

   © 2005 MaxStream, Inc. Confidential and Proprietary  44 

9XTend‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v1.2.4 

5.4. Multi-Transmit Mode

Attributes: Reliable Delivery through forced transmission of every RF packet

Every RF packet is sent exactly (MT + 1) times with no delays between packets

Diminished throughput and increased latency

Required Parameter Values (TX Modem): MT (Multi-Transmit) >= 1

Other Related Commands: Networking (DT, MK, MY, RN, TT), Serial Interfacing (BR, PK, RB ,

RO), RF Interfacing (FS)

Recommended Use: Use for applications that require Reliable Delivery without using retries an d acknowledgements.

5.4

.1. Connection Sequence

Events up through the ‘Transmit Packet’ process are common to all three RF

Communication O ptions. Refer to the Transmit

Mode section [p14] for more information.

Figure 5‐05. Multi‐Transmit Mode State Di agram 

In Multi-Transmit mode, each packet is retransmitted MT times, for a total of (MT+1) transmissions. There is no delay between retransmissions, and the transmitting modem will never receive RF data between retransmissions.

Each retransmission includes an RF initializer. A transmission event may include follow-on packets, each of which will be retransmitted MT times. The Forced Sync (FS) parameter is ignored in multiple-transmission mode.

The RB and RO parameters are not applied to follow-on packets, meaning that once transmission has begun, it will continue uninterrupted until the DI buffer is empty or the streaming limit (TT) has been reached. As with the first packet, the payload of each follow-on packet includes up to the maximum packet size (PK) bytes, and the transmitting modem checks for more pending data near the end of each packet. Follow-on packets are not sent until all retransmissions of the previous packet are finished.

The streaming limit (TT) is specified at the transmitting modem as the maximum number of bytes that the transmitting modem can send in one transmission event, which may consist of many packets. If the TT parameter is reached, the transmitting modem will force a random delay of 1 to RN delay slots (exactly 1 delay slot if RN is zero). In

Multi-Transmit mode, each packet is counted only once when tracking the streaming limit (TT), no matter how many times it is retransmitted.

When a receiving modem receives a Multi-Transmit packet, it calculates the amount of time remaining in the Multi-

Transmit event, and inhibits its own transmissions for the duration of the Multi-Transmit event, plus a random number of delay slots between 0 and (RN-1). If the local RN parameter is zero, the delay is only for the calculated duration of the Multi-Transmit event. Thus, a receiving modem need only receive one of the transmissions, and it will keep off the channel until the transmitting modem is done. If follow-on packets are coming, the receiving modems will move to the new frequency and listen for the follow-on packet for a specific period of time.

   © 2005 MaxStream, Inc. Confidential and Proprietary  45 

9XTend‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v1.2.4 

Appendix A:  Agency Certifications 

FCC Certification

The XTend RF Modem complies with Part 15 of the FCC rules and regulations. Compliance with labeling requirements, FCC notices and antenna regulations is required.

Labeling Requirements

In order to inherit MaxStream’s FCC Certification, OEMs and integrators are required to publish the text shown in Figure A-01 on the final product and within the final product operation manual.

Label Warning

WARNING The Original Equipment Manufacturer (OEM) must ensure that FCC labeling requirements are met. This includes a clearly visible label on the outside of the final product enclosure that displays the contents shown in the figure below.

Figure A‐01. Required FCC  Label for OEM products containing the 9XTend (900 MHz) OEM RF Modem 

Contains FCC ID: OUR-9XTEND

The enclosed device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference and (2) this device must accept any interference received, including interference that may cause undesired operation.

FCC Notices

Adherence to the following is required:

IMPORTANT: The XTend RF Modems have been certified by the FCC for use with other products without any further certification (as per FCC section 2.1091). Changes or modifications not expressly approved by MaxStream could void the user’s authority to operate the equipment.

IMPORTANT: OEMs must test their final product to comply with uni ntentional radiators (FCC section

15.107 and 15.109) before declaring compliance of their final product to Part 15 of the FCC Rules.

IMPORTANT: The XTend RF Modems have been certified for fix ed base station and mobile applications. If modems will be used for portable applications, the device must undergo SAR testing.

   © 2005 MaxStream, Inc. Confidential and Proprietary  46 

9XTend‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v1.2.4 

NOTE:

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by tur ning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

• Reorient o r relocate the receiving antenna.

• Increase the separation between the equipment and receiving modem.

• Connect the equipment into an outlet on a circuit different from that to which the receivin modem is connected. g

• Consult the dealer or a n experienced radio/TV technician for help.

Antenna Warning

WARNING: This device has been tested with Reverse Polarity SMA connectors with the antennas listed in Tables A-01 – A-07 of Appendix A. When integrated into OEM products, fixed antennas require installation preventing end-users from replacing them with non-approved antennas. Antennas not listed in the tables must be tested to comply with FCC Section 15.203 (unique antenna connectors) and Section

15.247 (emissions).

Limited Modular Approval

Power output is conducted at the antenna terminal and can be adjusted from 1 mill-watt to 1

Watt at the OEM level. The on-board OEM RF Module is approved for Limited Modular use operating as a mobile transmitting device with respect to section 2.1091 and is limited to OEM installation for Mobile and Fixed applications only. During final installation, end-users are prohibited from access to any programming parameters. Professional installation adjustment is required for s etting module power and antenna gain to meet EIRP compliance for high gain antenna(s).

Final antenna installation and operating configurations of this transmitter including antenna gain and cable loss must not exceed the EIRP of the configuration used for calculating MPE. Grantee

(MaxStream) must coordinate with OEM integrators to ensure the end-users and installers of products operating with the module are provided with operating instructions to sati sfy RF exposure requirements.

The FCC grant is valid only when the device is sold to OEM integrators. The OEM integrators are instructed to ensure the end-user has no manual instructions to remove, adjust or install the device.

   © 2005 MaxStream, Inc. Confidential and Proprietary  47 

9XTend‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v1.2.4 

FCC-Approved Antennas (900 MHz)

Fixed Base Station and Mobile Applications

MaxStream Modems are pre-FCC approved for use in fixed base station and mobile applications.

When the antenna is mounted at least 20 cm (8”) from nearby persons, the application is considered a mobile application.

Portable Applications and SAR Testing

When the antenna is mounted closer than 20 cm to nearby persons, then the application is considered “portable” and requires an additional test be performed on the final product. This test

and measures the emissions from the modem an d how they affect the person.

(T his statement must be included as a CAUTION statement in OEM produc t manuals.)

WARNING: This equipment is approved only for mobile and base station transmitting devices.

Antenna(s) used for this transmitter must be installed to provide a separation distance of at least 30 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter.

NOTE: The separa tion distance indicated in the above is 30 cm, but any distance greater than or equal to 23 cm ca n be used (per MPE evaluation).

To fulfill FCC Cer tification requirem ents:

1. Integrator must ensure required text [Figure A-01] is clearly placed on the outside of the final product.

2. XTend Modem may be used only with Approved Antennas that have been tested with this modem. [Refer to Tables A-01 – A-07]

1 Watt Transmit Power Output or Lower

Table A‐01. Half‐wave antennas (approved when operating at 1 Watt power output or lower.)   

Part Number

A09-HSM-7

A09-HABMM-P6I

A09-HBMM-P6I

A09-HRSM

A09-HASM-7

A09-HG

A09-HATM

A09-H

Type

Straight half -wave

Articulated half-wave w/ 6” pigtail

Straight half-wave w/ 6” pigtail

Right angle half-wave

Articulated half-wave

Glass mounted half-wave

Articulated half-wave

Ha lf-wave dipole

Connector

RPSMA

RPSMA

MMCX

MMCX

MMCX

RPSMA

RPSMA

RPSMA

RPTNC

RPSMA

Gain

3.0 dBi

2.1 dBi

2.1 dBi

2.1 dBi

2.1 dBi

2.1 dBi

2.1 dBi

2.1 dBi

2.1 dBi

2.1 dBi

Application

Fixed / Mobile

Fixed / Mobile

Fixed / Mobile

Fixed / Mobile

Fixed / Mobile

Fixed

Fixed

Fixed

Fixed

Fixed

Table A‐02. Yagi antennas (approved when operating at 1 Watt power output or lower.)   

Part Number Type Connector Gain Required Antenna Cable Loss Application

A09-Y6

A09-Y7

A09-Y8

A09-Y6TM

A09-Y7TM

A09-Y8TM

2 Element Yagi

3 Element Yagi

4 Element Yagi

2 Element Yagi

3 Element Yagi

4 Element Yagi

RPN

RPN

RPN

RPTNC

RPTNC

RPTNC

6.1 dBi

7.1 dBi

8.1 dBi

6.1 dBi

7.1 dBi

8.1 dBi

- 0.1 dB*

- 1.1 dB*

- 2.1 dB*

- 0.1 dB*

- 1.1 dB*

- 2.1 dB*

Fixed / Mobile

Fixed / Mobile

Fixed / Mobile

Fixed / Mobile

Fixed / Mobile

Fixed / Mobile

* FCC regulations stipulate a 36 dBm EIRP power requirement. Users implementing antenna gain greater than 6.0 dB must compensate for the  added gain with cable loss. When operating at 1 W power output, the sum (in dB) of cable loss and antenna gain shall not exceed 6.0 dB.  

   © 2005 MaxStream, Inc. Confidential and Proprietary  48 

9XTend‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v1.2.4 

A09-F5

A09-F6

A09-F7

A09-F8

A09-W7SM

A09-F0TM

A09-F1TM

A09-F2TM

A09-F3TM

A09-F4TM

A09-F5TM

A09-F6TM

A09-F7TM

A09-F8TM

A09-W7TM

Part Number

A09-F0

A09-F1

A09-F2

A09-F3

A09-F4

A09-F5

A09-F6

A09-F7

A09-F8

A09-W7

A09-F0

A09-F1

A09-F2

A09-F3

A09-F4

Table A‐03. Omni ‐directional base station antennas (approved when operating at  1 Watt power output or lower.)   

Type Connector

Fiberglass Base Station RPN

Gain

0

Required Antenna Cable Loss

-

Fiber -

-

Fiber glass Base Station RPN

-

-

-

- 0.1 dB* Fiberglass Base Station

Fiberglass Base Station

Fiberglass Base Station

Wire Base Station

RPN

RPN

RPN

RPN

Fibe rglass Base Station RPSMA

6.1 dBi

7.1 dBi

8.1 dBi

7.1 dBi

- 1.1 dB*

- 2.1 dB*

- 1.1 dB*

-

Fibe

Fibe rglass Base Station

Fiberglass Base Station

Fiberglass Base Station

Fiberglass Base Station

RPSMA 2.1

RPSMA

RPSMA

RPSMA

6.1 dBi

7.1 dBi

8.1 dBi

Wire Base Station RPSMA 7.1 dBi

Fiberglass Base Station RPTNC 0

-

-

-

-

-

- 0.1 dB*

- 1.1 dB*

- 2.1 dB*

Fiber

Fiberglass Base St dBi

Fiberglass Base St dBi

Fiber

Fiberglass

Wire Ba

Base Station

Fiberglass Base Station

Fiber glass Base Station se Station

RPTNC

RPTNC

RPTNC

RPTNC

6.1 dBi

7.1 dBi

8.1 dBi

7.1 dBi

- 1.1 dB*

-

-

-

-

-

-

- 0.1 dB*

- 1.1 dB*

- 2.1 dB*

- 1.1 dB*

Table A‐04. Mag Moun t antennas (approved when operating at 1 Watt powe r output or lower.)   

Part Number

A09-M0SM

A09-M2SM

A09-M3SM

A09-M5SM

A09-M7SM

A09-M8SM

A09-M0TM

A09-M2TM

A09-M3TM

A09-M5TM

A09-M7TM

A09-M8TM

Type

Mag Mount

Mag Mount

Mag Mo unt

Mag M ount

M ag Mount

M ag Mount

M a g Mount

Ma g Mount

Mag M ount

Mag Mount

Mag Mount

Mag M ount

Connector

RPSMA

RPSMA

RPSMA

RPSMA

RPSM

RPSM

RPT

RP

A

A

N C

RPTNC

RPTNC

TNC

RPTNC

RPTNC

Gain

0 dBi

2.1 dBi

3.1 dBi

5.1 dBi

7.1 dBi

8.1 dBi

0 dBi

2.1 dBi

3.1 dBi

5.1 dBi

7.1 dBi

8.1 dBi

Required Antenna Cable Loss

-

-

-

-

-1.1 d B*

-2.1 d B*

-

-

-

-

-1.1 dB*

-2.1 dB*

Table A‐05. Multi‐path antennas (approved when operating at 1 Watt power output or lower.)   

Part Number

A09-DPSM-P12F

A09-D3NF-P12F

A09-D3SM-P12F

A09-D3PNF

A09-D3TM-P12F

A09-D3PTM

A92-D4PNF

A92-D4P

A92-D4PTM

Type omni di rectional permanent mou omni directional w/ omni directional w/ nt w/ 12ft pigtail om ni directional mag netic mount w/ 12ft pi gtail

12ft pigt ail omni direction al permanent m ount

12ft pi gtail omni directional permanent mount

900 MHz / 2.4GHz permanent mount

900 MHz / 2.4GHz permanent mount

900 MHz / 2.4GHz permanent mount

Connector

RPSMA

RPN

RPSMA

RPN

RPTNC

RPTNC

RPN

RPSMA

RPTNC

Gain

3.0 dBi

3.0 dBi

3.0 dBi

3.0 dBi

3.0 dBi

3.0 dBi

2.1 dBi

2.1 dBi

2.1 dBi

Application

Fixed

Fixed

Fixed

Fixed

Fixed

Fixed

Fixed

Fixed

Fixed

Application

Fixed

Fixed

Fixed

Fixed

Fixed

Fixed

Fixed

Fixed

Fixed

Fixed

Fixed

Fixed

Fixed

Fixe d

Fixed

Fixed

Fixed

Fixed

Fixed

Fixed

Fixed

Fixed

Fixed

Fixed

Fixed

Fixed

Fixed

Fixed

Fixed

Fixed

Application

Fixed

Fixed

Fixed

Fixed

Fixed

Fixed

Fixed

Fixed

Fixed

Fixed

Fixed

Fixed

* FCC regulations  stipulate a 36  dBm EIRP  power requir ement. Users  implementing  antenna  gain greater  than 6.0 dB  must compe nsate for the  added gain with  cable  loss. When operat ing at 1 

W power ou tput, the sum 

(in dB) of cab le loss and  antenna gain shall n ot  exceed 6.0 dB.  

   © 2005 MaxStream, Inc. Confidential and Proprietary  49 

9XTend‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v1.2.4 

100 mi lliWatt Transmit Power Output or Low er

Table A‐06. Monopole a ntenn as (approve d whe n operating at 100 mW power output or lowe r.)   

Part Number

A09-QW

A09-QRAMM

A09-QSM-3

A09-QSM-3H

A09-QBMM-P6I

A09-QHSM-2

A09-QHRSM-2

A09-QHRSM-170

A09-QRSM-380

A09-QAPM-520

A09-QSPM-3

A09-QAPM-3

A09-QAPM-3H

5.2”

Type

Quarter-wa ve wire

3 “ Quarter-wave wire

Quarter-wav e straight

Heavy duty quarte r-wave st raight

Quart er-wave w/ 6” pigt ail

2” Stra

2" Right a

1.7" Right

3.8" Right

Articulated

3” Straight sc

3” Articulated s

3” Articulated s ight ngle

angle

angle

Screw mo rew moun crew mou crew mou unt t nt nt

Permanent

MMC X

RPSMA

RPSMA

M MCX

Pe rmanent

Pe rmanent

R PSMA

RPSMA

RPSMA

RPSMA

Permanent

Permanent

Permanent

Pe rmanent

Gain

1.9 dBi

1.9 dBi

1.9 dBi

1.9 dBi

1.9 dBi

1.9 dBi

1.9 dBi

1.9 dBi

2.1 dBi

1.9 dBi

1.9 dBi

1.9 dBi

-1 dBi

-1 dBi

1.9 dBi

A pplica tion

Fi xed / M obile

Fi xed / M obile

Fi xed / M obile

Fi xed / M obile

Fi xed / M obile

Fixed / Mobile

Fi xed / M obile

Fi xed / M obile

Fi xed / M obile

Fi xed / M obile

Fi xed / M obile

Fi xed / M obile

Fi xed / M obile

Fi xed / M obile

Fi xed / M obile

Table A‐07. Yagi  anten nas (app roved wh en ope rating at 100 mW  power o utput or lower.)    

Part Number

A09-Y6

A09-Y7

A09-Y8

A09-Y9

A09-Y10

A09-Y11

A09-Y12

A09-Y13

A09-Y14

A09-Y14

A09-Y15

A09-Y15

A09-Y6TM

A09-Y7TM

A09-Y8TM

A09-Y9TM

A09-Y10TM

A09-Y11TM

A09-Y12TM

A09-Y13TM

A09-Y14TM

A09-Y14TM

A09-Y15TM

A09-Y15TM

Type

2 Elemen t Yagi

3 Elemen t Yagi

4 Elemen t Yagi

4 Elemen t Yagi

5 Elemen t Yagi

6 Elemen t Yagi

7 Elemen t Yagi

9 Elemen t Yagi

10 Eleme nt Yagi

12 Element Yagi

13 Element Yagi

1 5 Elemen t Yagi

2 Elemen t Yagi

3 Elemen t Yagi

4 Elemen t Yagi

4 Elemen t Yagi

5 Elemen t Yagi

6 Elemen t Yagi

7 Elemen t Yagi

9 Elemen t Yagi

10 Eleme nt Yagi

12 Eleme nt Yagi

13 Eleme nt Yagi

15 Element Yagi

RPTNC

RPTNC

RPTNC

R PTNC

R PTNC

R

RPTNC

RPTNC

RPTNC

R

R

RPN

RPN

RPN

RPN

RPN

RPN

RPN

RPN

RPN

RPN

RPN

RPN

PTNC

PTNC

PTNC

RPTNC

Gain

14.1 dBi

14.1 dBi

15.1 dBi

15.1 dBi

6.1 dBi

7.1 dBi

8.1 dBi

9.1 dBi

10.1 dBi

6.1 dBi

7.1 dBi

8.1 dBi

9.1 dBi

10.1 dBi

11.1 dBi

12.1 dBi

13.1 dBi

11.1 dBi

12.1 dBi

13.1 dBi

14.1 dBi

14.1 dBi

15.1 dBi

15.1 dBi

Ap plica tion

Fi xed / Mo bile

Fi xed / Mo bile

Fi xed / Mo bile

Fi xed / Mo bile

Fi xed / Mo bile

Fi xed / Mo bile

Fi xed / Mo bile

Fi xed / Mo bile

Fi xed / Mo bile

Fixed / Mobile

Fixed / Mobile

Fix ed / M obile

Fi xed / Mo bile

Fi xed / Mo bile

Fi xed / Mo bile

Fi xed / Mo bile

Fi xed / Mo bile

Fi xed / Mo bile

Fi xed / Mo bile

Fi xed / Mo bile

Fi xed / Mo bile

Fi xed / Mo bile

Fi xed / Mo bile

Fixed / Mobile

IC (In dustry Canada) Certif ica tion

L a beling requirements for Industry C anada a re si milar to those of the F CC. A clea rly visible label o n the outside of the final p roduct en c losur e mus t displa y the foll owing text:

Contains Model 9XTend R adio, I C: 42 14A-9 XTEND

Integrator is responsible for its produc t to c omply with I C ICES-003 & FCC Part 1 5, Sub. B -

Unintentional Radiators. ICE S-003 is the same as FCC P art 15 Su b. B a nd Indust ry Canada accepts FCC test report or C ISPR 22 t est report fo r comp liance wi th ICE S-003.

   © 2005 MaxStream, Inc. Confidential and Proprietary  50 

9XTend‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v1.2.4 

Appendix  B:   Development Guide  

RS-232 Accessories Kit Contents

Th e accessories l isted below a re included w ith XTend RF M odems that carry t he “RA” suffix o n th e product number . For exam ple: Part num ber “XT09-PK C-RA” includ es the listed accessorie s an d part numbe r “XT09-P KC-R” does not. The a ccessorie are a nd software nee ded for dev eloping long range wireless link s. For test ing the m ode m’s ran ge, M axStream rec ommends t he purchase of one RF Modem w ith the ac cessories and one w ithout .

Ta ble B‐01.   Content s of the  XTend‐PKG‐R Accesso ries Kit 

Item

Quick Start Guide

Qty.

1

Description Part Number

Familiarizes users with some of the modem’s most imp ortant fun ctions.

MD0019 ntation, software and t ools need ed fo r RF M

D0018

XTend-PKG-R™

RS-232/ 485 RF M odem

Antenn a

1

1

Serial Loopback Adapter

NULL Modem Adapter (maleto-mal

NULL Modem Adapter

(fema

Male

Fema

Adapt

Powe

RS-2 e) le-to-female)

DB-9 to RJ-4 le DB-9 to RJ er r Adapter

32 Cable (6’)

-45

1

1

1

5 Adapter 1

1

1

1

Long Range 900 MHz RF Modem with RPSM A Conne ctor X T09-PK G

900 MHz RPSMA , 6" Half-Wave, dipole , articu lating

Connects to the f the MaxStream In configure the mo testing) emale RS-232 (DB-9) serial connect terface Board and ca dem to function as a re n be us peater ed to

(for ran or of ge

A 09-HAS

JD 2D3-C

M-675

DL-A

Connects to the fe the MaxStream In male RS-232 (DB-9) serial connect terface Board and ca n be us or of nnect JD 2D2-C the modem to ano ed to co ther DCE (female DB9) device

DN-A

Used to bypass ra dios to verify serial cabling is functio properly ning JD

3D3-C DN-A

Facilitates adapti

Interface Board t

RJ45) ng the DB-9 Connec o a CAT5 cable (mal tor of the e DB9 to f

MaxStr emale eam

J E1D2-C DA-A

Facilitates adapti

Interface Board t

RJ45) ng the DB-9 Connec o a CAT5 cable (fem tor of the ale DB9 to

MaxStr

fema eam le

Allows Interface B oard to be powered power supply

by a 110 Volt A C

Connects interfac e board to devices serial port having an RS-23 2

JE

JP

JD

1D3-C

4P2-9V

2D3-C

DA-A

10-6F

DS-6F

   © 2005 MaxStream, Inc. Confidential and Proprietary  51 

9XTend‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v1.2.4 

Adapters

The XTend Development Kit comes with several adapters that support the following functions:

• Performing Range Tests

• Testing Cables

• Connecting to other RS-232 DCE and DTE devices

• Connecting to terminal blocks or RJ-45 (for RS-485/422 devices)

NULL Modem Adapter (male-to-male)

Part Number: JD2D2-CDN-A (Black, DB-9 M-M) The male-to-male NULL modem adapter is used to connect two DCE devices. A DCE device c onnects with a straight-through cable to the male serial port of a computer (DTE).

Figure B‐01.   Male NULL modem adapter and pinouts 

Figure B‐02.   Example of a MaxSt ream Radio Modem (DCE Device) connecting to  another DCE device) 

NULL Modem Adapter (fem aleto-female)

Part Number: JD3D3CDN-A ( Gray, DB-9 F-F) The female-to-female NUL L modem adapter is used to verify serial ca bli ng is functioning properly. To test cables, insert th e female-to -female

NULL mod em adapter in place of a pair of RF modems and test the co nnection without radio modems in the co io

Figure B‐03.   Female NULL mode m adapter and pinouts 

Male and female DB‐9 to RJ‐45  adapters are also included in  the accessories kit. Refer to the 

“RS‐485/422 Connection 

Guidelines” section [p11] for 

more info. 

Ser ial Loopback Adapter

Part Number: JD2D3-CDL-A (Red, DB-9 M-F) The serial loopback adapter is used for range testing. During a range test, the serial loopback adapter configures the radio modem to function as a repeater by looping serial data back into the radio for retransmission.

Figure B‐04.   Serial loopback adapter and pinouts 

   © 2005 MaxStream, Inc. Confidential and Proprietary  52 

9XTend‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v1.2.4 

Antennas

[Refer to Appendix A for a list of FCC-Approved Antennas]

Fa r link range:

• Ambient RF nois e (interference)

• Line-of-sight obstructions

• Transmit power

• Receive sensitivity

• Antenna configuration

XTe nd Antenna Connector Options

To comply with the FCC rules and obtain a “modular” certification, it is required that XTend

Modems utilize a “non standard” connector. This is to ensure the modems are used only with approved antennas. The XTend RF Modem accepts RPSMA antennas.

R PSMA

T he Reverse Polarity SMA (RPSMA) connector uses the same body as a re gular SMA connector. In order to be a “non standard” connector, the gender of t he center conductor is changed. The female RPSMA actually has a ma le center conductor.

An tenna Cables

RF cabl es are typically used to connect a radio installed in a cabinet to an antenna moun ted externally . As a general rule, it is best to keep the RF cable as short as possible. All cables p romote signal loss which is usually measured in dB loss per 100 ft. MaxStream provides LMR-

1 95 rated cables. Common cables and dB losses are included in this table:

T able B‐02.   Potential Signal Strength Loss due to Antenna Cable Length 

Cable

Type

RG-58

RG-174

RG-316

LMR-195

LMR-240

LMR-600

Loss at 900 MHz per 100’

(loss per 100m)

14.5 (47.4) dB

25.9 (85.0) dB

24.7 (81.0) dB

11.1 (36.5) dB

7.6 (24.8) dB

2.5 (8.2) dB

Loss at 2.4 GHz per 100’

(loss per 100m)

25.3 (83.2) dB

44.4 (145.84) dB

42.4 (139.0) dB

19.0 (62.4) dB

12.9 (42.4) dB

4.4 (14.5) dB

Diameter

0.195” (4.95 mm)

0.100” (2.54 mm)

0.102” (2.59 mm)

0.195” (4.95 mm)

0.240” (6.10 mm)

0.590” (14.99 mm)

   © 2005 MaxStream, Inc. Confidential and Proprietary  53 

9XTend‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v1.2.4 

Appendix  C:  Add itional Information 

1 Year Warranty

 

XTend RF Modems from MaxStream, Inc. (the ʺProductʺ) are warranted against defects in materials  and workmanship under normal use, for a period of 1‐year from the date of purchase. In the event of  a product  failure due to materials or workmanship, MaxStream will repair or replace the defective  product. F or warranty service, return the defective product to MaxStream, shipping prepaid, for  prompt repair or replacement. 

The foregoing sets forth the full extent of MaxStreamʹs warranties regarding the Pr o duct. Repair or  replacement at MaxStreamʹs option is the exclusive remedy. THIS WARRANTY IS  GIVEN IN LIEU 

OF ALL OTHER WARRANTIES, EXPRESS  OR IMPLIED, AND MAXSTREAM SPECIFICALLY 

DISCLAIMS ALL  WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR 

PURPOSE. IN NO  EVENT SHALL MAXSTREAM, ITS SUPPLIERS OR LICENSORS BE LIABLE FOR 

DAMAGES IN EXCESS OF THE PURCHASE PRICE OF THE PRODUCT, FOR ANY LOSS OF USE, 

LOSS OF TIME, INCONVENIENCE, COMMERCIAL LOSS, LOST PROFITS OR SAVINGS, OR 

OTHER INCIDENTAL, SPECIAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE 

OR INABILITY TO USE THE PRODUCT, TO THE FULL EXTENT SUCH MAY BE DIS CLAIMED BY 

LAW. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION  OF INCIDENTAL OR 

CO NSEQUE NTIA L DAMAGES. THEREFOR, TH E FOREGOING  EXCLUSIONS MA Y NOT APPLY 

IN  ALL CA SES. T his warranty provides specific le gal r ights . Other rights wh ich va ry from  state to  sta te may  also apply. 

Ordering Infor mation

F igure C‐01 .   MaxStream  RF Modem  Part Numbers Key 

   © 2005 MaxStream, Inc. Confidential and Proprietary  54 

9XTend‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v1.2.4 

Contact MaxStream

Free and unlimited technical support is included with every MaxStream Radio Modem sold.

Please use the following resources for additional support:

Documentation:

Technical Support: http://www.maxstream.net/helpdesk/download.php

Phone. (866) 765-9885 toll-free U.S. & Cana da

Live Chat.

E-Mail. www.maxstream.net

[email protected]

MaxStream office hours are 8:00 am – 5:00 pm [U.S. Mountain Standard Time]