Buffalo GEN154A KingCraft 2000 Watt Generator Instruction manual

Add to my manuals
24 Pages

advertisement

Buffalo GEN154A KingCraft 2000 Watt Generator Instruction manual | Manualzz

201002

GEN154A

2000 Surge Watts / 1200 Running Watts

PORTABLE GENERATOR

INSTRUCTION MANUAL

READ ALL INSTRUCTIONS AND WARNINGS BEFORE USING THIS PRODUCT.

This manual provides important information on proper operation & maintenance. Every effort has been made to ensure the accuracy of this manual. These instructions are not meant to cover every possible condition and situation that may occur. We reserve the right to change this product at any time without prior notice.

IF THERE IS ANY QUESTION ABOUT A CONDITION BEING SAFE OR UNSAFE,

DO NOT OPERATE THIS PRODUCT!

DO NOT RETURN THIS PRODUCT TO THE RETAILER - CONTACT CUSTOMER SERVICE.

If you experience a problem, have questions or need parts for this product, call Customer Service at

1-866-460-9436, Monday-Friday, 8 AM - 4 PM Central Time. A copy of the sales receipt is required.

FOR CONSUMER USE ONLY – NOT FOR PROFESSIONAL USE.

KEEP THIS MANUAL, SALES RECEIPT & APPLICABLE WARRANTY FOR FUTURE

REFERENCE.

GEN154A 2000 Surge Watts / 1200 Running Watts Portable Generator

FEATURES:

4-Stroke OHV Engine

Recoil Start

2.8 HP Unleaded Gasoline Engine / 3600 RPM

2-120 Volt 60 Hz / 10 AMP AC Outlets

1-12 Volt DC Outlet / 8 AMP

1.8 Gallon Fuel Tank

Engine Run Time: 11 Hours @ 50% Load

2000 Surge Watts / 1200 Running Watts

EPA Approved

Insulation class F

Power Factor 1.0

GEN154A 2000 Surge Watts/1200 Running Watts Portable Generator 2

TABLE OF CONTENTS

PACKAGE CONTENTS

PACKAGE

PREPARING THE GENERATOR FOR USE...................................................................................................................11

Using This Generator For The First Time .............................................................................................................11

Step 1 – Add Oil...........................................................................................................................................11

Step 2 – Add Unleaded Gasoline.................................................................................................................12

Step 3 – Ground The Generator...................................................................................................................12

Subsequent Use Of This Generator......................................................................................................................13

Step 1 – Verify Oil Level...............................................................................................................................13

Step 2 – Verify Unleaded Gas Level ............................................................................................................13

Step 3 – Ground The Generator...................................................................................................................13

STARTING THE GENERATOR.......................................................................................................................................14

USING THE GENERATOR..............................................................................................................................................15

Usage .............................................................................................................................................................15

Usage .............................................................................................................................................................17

MAINTENANCE/CARE....................................................................................................................................................18

The Generator .......................................................................................................................................18

Checking The Oil Level.........................................................................................................................................19

Changing/Adding Oil.............................................................................................................................................19

Air Maintenance...........................................................................................................................................20

Plug

Emptying

THIS ENGINE MEETS U.S. EPA EMISSION STANDARDS UNDER 40 CFR 1054.625 .

The emission-related warranty is valid for two (2) years. Keep the purchase receipt and mail in the product registration card for proof of purchase.

NB Corp limits emission-related warranty repairs to authorized service centers for owners located within 100 miles of an authorized service center.

For owners located more than 100 miles from an authorized service center, NB Corp will, in its sole discretion, either pay for shipping costs to and from an authorized service center, provide for a service technician to come to the owner to make the warranty repair, or pay for the repair to be made at a local non-authorized service center. The provisions of this paragraph apply only for the contiguous states, excluding the states with high-altitude areas identified in 40 CFR part 1068, Appendix III.

To exercise this warranty, DO NOT RETURN TO RETAILER. Instead, call Customer Service toll free at 1-866-460-9436 (email address [email protected]) and you will be instructed on where to take the engine for warranty service. Take the generator and proof of purchase (your receipt) to the repair facility recommended by the Customer Service Representative. The warranty does not extend to generators damaged or affected by fuel contamination, accidents, neglect, misuse, unauthorized alterations, use in an application for which the product was not designed and any other modifications or abuse.

1 YEAR LIMITED WARRANTY

Generators are warranted to be free from defects in materials and workmanship for a period of 1 year from date of original purchase. NB Corp. is not liable for any indirect, incidental or consequential damages from the sale or use of this product. Any implied warranties are limited to 1 year as stated, or as otherwise stated, in this written limited warranty. Some states do not allow the exclusion or limitation of incidental or consequential damages. Some states do not allow limitation on the length of an implied warranty. NB Corp will repair or replace, at its discretion, any part that is proven to be defective in materials or workmanship under normal use during the 1 year warranty period. Warranty repairs or replacements will be made without charge for parts or labor. Parts replaced during warranty repairs will be considered as part of the original product and will have the same warranty period as the original product. This warranty gives you specific legal rights, and you may have other rights that vary from state to state.

GEN154A 2000 Surge Watts/1200 Running Watts Portable Generator 3

RECOGNIZE SAFETY SYMBOLS, WORDS AND LABELS

What You Need to Know About Safety Instructions

Warning and Important Safety Instructions appearing in this manual are not meant to cover all possible conditions and situations that may occur. Common sense, caution and care must be exercised when operating or cleaning tools and equipment.

Always contact your dealer, distributor, service agent or manufacturer about problems or conditions you do not understand.

This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death.

DANGER indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.

WARNING indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.

CAUTION indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury.

CAUTION used without the safety alert symbol indicates a potentially hazardous situation which, if not avoided, may result in property damage.

GEN154A 2000 Surge Watts/1200 Running Watts Portable Generator 4

Notice Regarding Emissions:

Engines certified to comply with California and U.S. EPA emission regulations for SORE (Small Off Road Equipment) are certified to operate on regular unleaded gasoline and may include the following emission control systems: Three-Way Catalyst (TWC) (if equipped), and Engine

Modifications (EM).

Legal Requirements:

Federal and/or State Occupational Safety and Health Administration (OSHA) regulations, local codes, and/or ordinances may apply to the intended use of this generator. Consult a qualified electrician, electrical inspector, and/or the local agency having jurisdiction. Some areas require generators to be registered with local utility companies. Additional regulations may apply if this generator will be used at a construction site.

IMPORTANT SAFETY INSTRUCTIONS

STOP!

Before using this generator and if you have any questions regarding the hazard and safety notices listed in this manual and/or on this generator, call 1-866-460-9436, Monday - Friday, 8 AM - 4 PM Central Time.

Carbon Monoxide Gas:

Generator exhaust contains carbon monoxide (CO2). This is a poison gas you cannot see or smell. If you can smell the generator exhaust, you are breathing CO2. But even if you cannot smell the exhaust, you could be breathing CO2. • NEVER use a generator inside homes, garages, crawlspaces, or other partly enclosed areas. Deadly levels of carbon monoxide can build up in these areas.

Using a fan or opening windows and doors does NOT supply enough fresh air.

• ONLY use a generator outside and far away from windows, doors, and vents. These openings can pull in generator exhaust. Even when you use a generator correctly, CO2 may leak into the home. ALWAYS use a battery-powered or battery-backup CO2 alarm in the home.

• If you start to feel sick, dizzy, or weak after the generator has been running, move to fresh air RIGHT AWAY. See a doctor. You could have carbon monoxide poisoning.

Chemicals:

According to the State of California, the exhaust from this generator contains chemicals known to cause cancer, birth

defects, or other reproductive harm.

Flammable Gasoline:

This generator may emit highly flammable and explosive gasoline vapors, which can cause severe burns or

even death. A nearby open flame can lead to an explosion even if not directly in contact with gasoline.

• Do not operate this generator near open flame.

• Do not smoke near this generator.

• Always operate this generator on a firm, level surface.

Gasoline is highly flammable and explosive. Handling fuel can result in serious injury or burns.

• Always shut down this generator before refueling. Refuel in a well-ventilated area. Keep heat, sparks and flame away while refueling and away from the location where gasoline is stored. Never refuel indoors where gasoline fumes may reach flames and/or sparks.

• Allow this generator to cool for at least 2 minutes before removing the fuel tank cap. Loosen the cap slowly to relieve pressure in the fuel tank. Avoid spilling fuel.

• Do not fill the fuel tank above the upper limit line. Gasoline may expand during operation. Do not fill to the top of the tank.

• Always check for spilled gasoline and immediately wipe it up before starting this generator.

• Empty the fuel tank before storing or transporting this generator.

• Always handle fuel outdoors.

• Before transporting, turn the fuel valve to the “OFF” position and disconnect the spark plug.

Environment Required:

Protect the generator from direct sunlight. Do not select a location that is permanently subject to temperatures of more than 40 °C and less than -15°C.

• If the generator is not operated at a temperature of between 5 - 40 °C and a height of 0 - 1000 m, the connected power consumption must be reduced!

• Prevent this to ensure the longevity of the device and hazards!

GEN154A 2000 Surge Watts/1200 Running Watts Portable Generator 5

Powerful Voltage:

This generator produces powerful voltage, which can result in electrocution.

• ALWAYS ground this generator before using it. (See “Ground the Generator” section in this manual).

• Only electrical devices should be plugged into this generator, either directly or with an extension cord. NEVER connect a building electrical system to this generator without a qualified electrician. Such connections must isolate generator power from utility power and comply with local electrical laws and codes. Failure to comply can create a back feed into utility lines creating an electrocution hazard, which may result in serious injury or death to utility workers. Such a back feed may cause this generator to explode, burn and create fires when utility power is restored.

• Use a ground fault circuit interrupter (GFCI) in highly conductive areas such as metal decking or steel work. GFCIs are available in-line with some extension cords.

• Do not use this generator in wet conditions (rain, snow, active sprinkler system, wet hands, etc.). Always keep this generator dry and operate it with dry hands.

• Do not touch bare wires or outlets (receptacles).

• Do not allow children or non-qualified persons to operate this generator.

High Temperatures:

This generator produces heat when in operation. Temperatures near the exhaust can exceed 150 Degrees

Fahrenheit (65 Degrees Celsius).

• Do not touch hot surfaces. Observe all warning placards on this generator denoting hot surfaces.

• Allow this generator to cool for several minutes after use before touching the engine, muffler or other areas that are hot during operation and before storing indoors.

• Hot exhaust may ignite some materials. Keep flammable materials away from this generator.

• Keep at least several feet of clearance on all sides of this generator during operation. Do not enclose this generator in any structure.

Usage:

Misuse of this generator can damage it or shorten its life.

• Use this generator only for its intended purpose.

• Operate this generator only on a dry, level surface. Do not secure the generator with a chain or rope, which would prevent it from being moved in an emergency.

• Allow this generator to run for several minutes before connecting any electrical devices.

• Promptly turn off any malfunctioning devices and disconnect them.

• Do not operate an excessive number of electrical devices in excess of the wattage capacity of this generator.

• Do not turn on electrical devices until after they are connected to this generator.

• Turn off all connected electrical devices before stopping this generator.

• Generators vibrate in normal use. During and after the use of the generator, inspect the generator as well as extension cords and power supply cords connected to it for damage resulting from vibration.

• Have damaged items repaired or replaced as necessary.

• Do not use plugs or cords that show signs of damage such as broken or cracked insulation or damaged blades.

• For power outages, permanently installed stationary generators are better suited for providing backup power to the home.

• Even a properly connected portable generator can become overloaded.

• This may result in overheating or stressing the generator components, possibly leading to a generator failure.

GEN154A 2000 Surge Watts/1200 Running Watts Portable Generator 6

GEN154A 2000 Surge Watts/1200 Running Watts Portable Generator 7

In addition to the previously described safety information, familiarize yourself with all safety and hazard placards on this generator.

GEN154A 2000 Surge Watts/1200 Running Watts Portable Generator 8

PACKAGE CONTENTS

The following items are supplied with this Model GEN154A 2000 Surge Watts / 1200 Running Watts Portable Generator. Verify that all items are included.

STOP!

If there are missing items, call 1-866-460-9436, Monday - Friday, 8 AM - 4 PM Central Time for customer service. DO NOT RETURN THIS

GENERATOR TO THE RETAILER.

Item List:

NEMA L14-30 plug for connecting 120 Volt electrical devices

Spark plug wrench

GEN154A 2000 Surge Watts/1200 Running Watts Portable Generator 9

GENERATOR COMPONENTS

Observe the locations and functions of the various components and controls of this generator.

1) Fuel Tank Cap

2) Control Panel

3) Grounding Terminal

4) Oil Access

5) Recoil Starter

6) Carburetor Choke Lever

7) Fuel Cock

8) Power On/Off

9) 120 V AC Outlets 10 Amp

10) 12 Volt DC Outlet 8 Amp

1

8

7

6

5

4 9

13

12

11) Pilot Lamp

Reset

13) DC

2

3

10

11

GEN154A 2000 Surge Watts/1200 Running Watts Portable Generator 10

PREPARING THE GENERATOR FOR USE

Using this Generator for the First-Time

STOP!

The following section describes the required steps for preparing this generator for the first use. Failure to correctly perform these steps can damage this generator and/or shorten its life. If still unsure about how to perform any of these steps after reading this section, call

1-866-460-9436 Monday - Friday, 8 AM - 4 PM Central Time for customer service.

If this generator is being used for the first time, the following few steps are required to prepare it for operation:

Step 1 - Add Oil

This generator requires engine oil to function. Engine oil is a major factor affecting engine performance and service life. When new from the package, this generator contains no oil in the engine crankcase. The correct quantity of oil is equal to the oil capacity of the engine crankcase and is 13.5 fluid oz (0.40 L) for this Model GEN154A 2000 Surge Watts / 1200 Running Watts Portable Generator. Add the correct quantity of oil before operating this generator for the first time. When replenishing oil for subsequent use of this generator, always determine that this generator has the correct quantity of oil.

Model GEN154A Oil Capacity (fluid oz./L)

Model GEN154A Oil Type Recommended

To add oil:

13.5 / 0.4

SAE10W-30

1. Confirm that this generator is on a level surface.

2. Open the Oil Access Panel as illustrated in Figure 1.

3. Using a funnel, add high detergent motor oil to fill the engine crankcase to the correct quantity as stated above. SAE10W-30 oil is recommended.

When the engine crankcase is full, the oil level should reach the lower lip of the oil filling opening as illustrated in Figure 2.

4. Replace the oil filler/dipstick cap and close the oil access panel.

Figure 1 – Open the Oil Access Panel

GEN154A 2000 Surge Watts/1200 Running Watts Portable Generator

Figure 2 - Adding Oil

11

Step 2 - Add Unleaded Gasoline Only

Gasoline and gasoline fumes are highly flammable and explosive. Handling fuel can result in serious injury or burns.

• Do not fill the fuel tank near a heat, sparks or an open flame. Keep gasoline away from appliance pilot lights, barbecues, electric appliances, power tools, etc.

• Do not overfill the fuel tank. Always check for fuel spills and immediately wipe them up. Spilled fuel is a fire hazard and causes environmental damage.

To add Unleaded Gasoline:

To ensure that this generator runs smoothly, use only FRESH, UNLEADED GASOLINE WITH AN OCTANE RATING OF 87 OR HIGHER. Unleaded gasoline produces fewer engine and spark plug deposits and extends the life of the exhaust system.

1. Confirm that this generator is on a level surface.

2. Unscrew fuel tank cap and set aside. (NOTE: The fuel tank cap may be tight and difficult to unscrew.)

3. Slowly add fresh, unleaded gasoline (with an octane rating 87 or higher) to the fuel tank. Be careful not to fill the fuel tank above the upper limit line. The fuel tank capacity for this generator is 1.5 gallon (7 L). NOTE: Because gasoline can expand, do not fill the fuel tank to the very top.

4. Securely tighten the fuel tank cap and immediately wipe up any spilled gasoline with a dry cloth.

Model GEN154A Fuel Tank Capacity (gals /L)

Model GEN154A Fuel Type

IMPORTANT:

• Use only UNLEADED gasoline with an octane rating of 87 or higher.

1.5 / 5.8

Fresh, Unleaded Gasoline Octane Rating 87 or Higher

• Never use a mixture of oil and gasoline.

• Never use old and/or contaminated gasoline.

• Avoid getting dirt and/or water in the fuel tank.

• Gasoline can age in the fuel tank and make it difficult to start this generator. Never store this generator for extended time with gasoline in the fuel tank.

Step 3 - Ground the Generator

Failure to properly ground this generator can result in electrocution.

Ground this generator by tightening the grounding nut against a grounding wire as illustrated in Figure 3. A No. 12 AWG (American Wire Gauge) stranded copper wire is generally an acceptable grounding wire. The other end of this grounding wire should be connected to a copper or brass grounding rod that is driven into the earth.

Grounding codes can vary by location. Contact a local electrician for information on grounding regulations for your area.

Figure 3

The Grounding Terminal is located on the front of the generator, to the right of the DC Output socket.

GEN154A 2000 Surge Watts/1200 Running Watts Portable Generator 12

Subsequent Use of this Generator

For subsequent uses of this generator after the first use, certain steps still must be completed to prepare it for operation.

IMPORTANT: Be familiar with the procedures described in the previous section titled “Using the Generator for the First Time” of this manual. If not, review this section now.

Step 1 - Verify Oil Level

It is important to check the oil level in the engine crankcase before each use to ensure that there is sufficient quantity.

1. Verify that this generator is on a level surface.

2. Unscrew the oil filler/dipstick cap from the engine.

3. With a dry cloth, wipe the oil off of the dipstick that is located on the inside of the cap.

4. Fully insert the dipstick without screwing the filler/dipstick cap and then remove again. There should be oil on the dipstick. If there is no oil on the dipstick, or oil is visible only at the very end of the dipstick, add oil until the engine crankcase is filled. (See “Changing/Adding Oil” in the

“Maintenance/Care” section of this manual).

5. Confirm that the oil filler/dipstick cap is properly screwed in place when finished verifying the oil level.

Step 2 - Verify Gas Level

Before starting this generator, verify that there is sufficient gasoline in the fuel tank. The fuel gauge, located on the top of this generator, indicates the gas level currently in the fuel tank. If necessary, add fresh unleaded gasoline with an octane rating of 87 or higher according to “Step 2 - Add

Gasoline” of the “Using this Generator for the First Time” section of this manual.

Model GEN154A Fuel Tank Capacity (gals /L)

Model GEN154A Fuel Type

1.5 / 5.8

Fresh, Unleaded Gasoline Octane Rating 87 or Higher

Gasoline and gasoline fumes are highly flammable and explosive. Handling fuel can result in serious injury or burns.

• Do not fill the fuel tank near a heat, sparks or an open flame. Keep gasoline away from appliance pilot lights, barbecues, electric appliances, power tools, etc.

• Always allow several minutes for the engine to cool before refueling.

• Do not overfill the fuel tank. Always check for fuel spills and immediately wipe them up. Spilled fuel is a fire hazard and causes environmental damage.

IMPORTANT:

• Use only fresh UNLEADED gasoline with an octane rating of 87 or higher.

• Never use old and/or contaminated gasoline.

• Never use a mixture of oil and gasoline.

• Avoid getting dirt and/or water in the fuel tank.

• Never store generator for extended time with gasoline in the fuel tank.

Step 3 - Ground the Generator

Failure to properly ground this generator can result in electrocution.

Ground this generator by tightening the grounding nut against a grounding wire as previously illustrated in Figure 3. A generally acceptable grounding wire is a No. 12 AWG (American Wire Gauge) stranded copper wire. The other end of this grounding wire should be connected to a copper or brass grounding rod that is driven into the earth.

Grounding codes can vary by location. Contact a local electrician for information on grounding regulations for your area.

GEN154A 2000 Surge Watts/1200 Running Watts Portable Generator 13

STARTING THE GENERATOR

STOP!

Before starting this generator, confirm that all the steps in the section titled, “Preparing the Generator for Use,” of this manual have been correctly completed. If unsure about how to perform any of these steps, call 1-866-460-9436, Monday - Friday, 8 AM - 4 PM Central Time for customer service.

Disconnect all electrical loads from this generator before attempting to start.

To start this generator:

1. Confirm that there are no electrical devices connected to this generator. Connected devices may increase the difficulty in starting the engine.

2. Confirm that this generator is properly grounded. (See “Ground the Generator” section of this manual.)

3. Turn the fuel valve to the “on” position.

4. Move the choke lever to the “closed” position.

5. Set the engine switch to the “on” position.

6. Slowly pull on the recoil starter handle, shown in Figure 4, until a slight resistance is felt. Then pull briskly to start the engine. Gently return the cord into the generator to avoid damage to the starter or housing. Never allow the cord to snap back.

7. If the engine fails to start, repeat step 6. NOTE: After repeated attempts to start the engine, consult the troubleshooting guide before attempting again. If problems persist, call 1-866-460-9436, Monday - Friday, 8 AM - 4 PM Central Time.

8. Once the engine has started and runs for about a minute, move the choke lever approximately half way towards the “open” position. Wait an additional 30 seconds and then move the choke lever completely over to the “open” position.

9. Allow this generator to run for several minutes before connecting any electrical devices.

Figure 4

The Recoil Start is located on the left side of the generator.

GEN154A 2000 Surge Watts/1200 Running Watts Portable Generator 14

USING THE GENERATOR

• USE THIS GENERATOR ONLY OUTDOORS IN NON-CONFINED AREAS. DO NOT SECURE THE GENERATOR WITH A CHAIN OR ROPE, AS

THIS WILL MAKE IT DIFFICULT TO MOVE IN AN EMERGENCY.

• Keep at least several feet of clearance on all sides to allow proper ventilation for this generator.

After the engine has been running for several minutes, electrical devices may be connected to this generator.

AC Usage

Electrical devices running on AC current may be connected according to their wattage requirements. The rated (running) and surge wattage for this

Model GEN154A 2000 Surge Watts / 1200 Running Watts Portable Generator is 1,200 and 2,000 respectively.

The rated (running) wattage corresponds to the maximum wattage a generator can output on a continuous basis.

The surge wattage corresponds to the maximum amount of power a generator can output for a short time. Many electrical devices, such as a refrigerator, require short bursts of extra power for starting and stopping fan motors, etc., in addition to their listed rated wattage. Motorized devices typically require more than their rated wattage for startup. The surge wattage ability of a generator allows for this extra power requirement.

The total running wattage requirement of the electrical devices connected to a generator should not exceed the rated wattage of the generator itself.

To calculate the total wattage requirement of the electrical devices to be connected, look up the rated (running) wattage of each device and add these numbers together to find the total wattage that all of the devices together will draw from the generator. If the total wattage of the selected devices exceeds the rated wattage of the generator, DO NOT connect all of the devices. Select a combination of the electrical devices that will have a total wattage less than or equal to the rated wattage for the generator.

This generator can run at its surge wattage capacity for only a short time. Connect electrical devices requiring a rated (running) wattage equal to or less than the rated wattage of this generator. Never connect devices requiring a rated wattage equal to the surge wattage of a

generator.

A device's rated (running) wattage should be listed somewhere on the device itself and/or in its manual. If the wattage specification for a device is not available, the wattage can be calculated by multiplying the Voltage requirement (120 or 240) by the Amperage drawn.

Watts = Volts x Amperes

Or, the wattage required by a device can be estimated by using the following chart. The chart provides only estimates and it is better to know the exact wattage of each electrical device to be powered by this generator.

Electrical Device Rated (Running) Watts Additional Surge Watts

air compressor (1 - 1/2 HP) 2500 2500 airless sprayer (1/3 HP) coffee maker computer w/17 inch monitor deep freezer electric drill (1/2 HP) furnace fan blower (1/2 HP) hot plate microwave oven (1000 watt) quartz halogen work light refrigerator/freezer (18 Cu. Ft.) saw - circular (7 1/4 inch) stereo receiver electric stove - single element sump pump television (27 inch color) well water pump (1/3 HP) window air conditioner (10000 BTU) window fan

1000

800

1500

450

1500

800

500

1000

1200

300

600

1500

800

500

1000

800

2500

1000

0

1600

1500

0

0

1200

0

2000

1800

600

1200

0

0

500

1000

1300

0

0

Connect electrical devices to this generator according to the following procedure:

Allow the engine to run for several minutes after it has been started.

Confirm that the electrical device is switched off prior to plugging it into this generator.

Connect only electrical devices that are in good working order. Faulty devices or power cords present the risk of electrical shock.

Immediately turn off and disconnect any device that commences to operate abnormally, sluggish or abruptly stops. Determine if the

GEN154A 2000 Surge Watts/1200 Running Watts Portable Generator 15

problem was the device or the rated load capacity of this generator has been exceeded.

NOTE: Plug appliances into the correct outlet. Connect standard 120 Volt, single phase, 60 Hz loads to the 120 Volt outlet. Connect 12 Volt, DC loads to the 12 Volt outlet.

Even though this generator has an overall rated wattage of 2000, do not attempt to draw more than 1200 Watts from the 120 Volt outlet.

Draws higher than 1200 Watts will damage this generator and void the warranty.

NOTE: While this generator is running, power is available from either the standard 120 Volt outlet or the 12 Volt DC outlet. Both 120 Volts and 12

Volts can be simultaneously drawn from this generator.

Turn on the connected electrical devices beginning with the device with the highest rated wattage requirement and then each additional device with the next lower rated wattage requirement.

Do not connect 50Hz or 3-phase loads to this generator.

GEN154A 2000 Surge Watts/1200 Running Watts Portable Generator 16

SOME NOTES ABOUT POWER CORDS

Long or thin cords can require more wattage from a generator to power an electrical device. Figure 6 shows the recommended cords according to the power requirement of the electrical device. When using cords that exceed these specifications, allow for the electrical device to have a slightly higher rated wattage requirement.

Device Requirements Max. Cord Length (ft) by Wire Gauge

Amps Watts (120V) Watts (240V) #8 wire #10 wire #12 wire #14 wire #16 wire

2.5 300 600 NR 1000 600 375 250

5 600 1200 NR 500 300 200 125

7.5 900 1800 NR 350 200 125 100

10 1200 2400 NR 250 150 100 50

30 3600 7200 125 65 NR NR NR

40 4800 9600 90 NR NR NR NR

NR = Not Recommended.

Figure 6 - Maximum Extension Cord Lengths by Power Requirement

DC Usage

The DC outlet is only for recharging 12 Volt automotive-type batteries. Do not connect any other device to this outlet.

Use this generator only for recharging 12 Volt batteries. NEVER attempt to jumpstart a car with this generator.

Failing to use the correct procedure can cause a battery to explode, seriously injuring anyone nearby. Keep heat, sparks, flame and

smoking materials away from the battery.

To connect 12 Volt batteries to the DC outlet:

1. Connect one charging wire to the positive terminal of the battery and the other charging wire to the negative terminal of the battery.

2. Connect the free end of the positive wire to the positive side of the outlet on this generator.

3. Start this generator.

4. Carefully connect the free end of the negative wire to the negative side of the outlet on this generator.

5. When disconnecting, always disconnect the wires from this generator first to avoid a spark.

Storage batteries emit highly explosive hydrogen gas when charged.

Batteries also contain acid, which can cause severe chemical burns.

• Do not allow open flames or cigarettes nearby for several minutes after charging a battery.

• Always wear protective goggles and rubber gloves when charging a battery.

• If battery acid gets on the skin, flush with water.

• If battery acid gets in the eyes, flush with water and immediately call a physician.

• If battery acid is swallowed, drink large quantities of milk and immediately call a physician.

Do not secure the generator with a chain or rope, which would prevent it from being moved in an emergency.

GEN154A 2000 Surge Watts/1200 Running Watts Portable Generator 17

STOPPING THE GENERATOR

To stop this generator:

1. Turn off all connected electrical devices and then unplug them.

2. Switch the circuit breaker to the “OFF” position.

3. Allow this generator to run for several more minutes with no electrical devices connected to help stabilize the temperature of this generator.

4. Set the engine switch to the “OFF” position.

5. Turn the fuel valve to the “OFF” position.

Allow this generator to cool down before touching areas that become hot during operation.

Allowing gasoline to sit in this generator's fuel tank for extended time without use can increase the difficulty in starting this generator in

the future. Never store this generator for extended time with gasoline in the fuel tank.

MAINTENANCE/CARE

Proper routine maintenance of this generator is essential for safe, economical, and trouble-free operation. It will help prolong the life of this generator as well as help reduce air pollution. Perform maintenance checks and procedures according to the schedule in Figure 7.

Never perform maintenance procedures while this generator is running. Allow this generator to cool before commencing any maintenance

procedures. Keep heat, sparks and flame away.

Improper maintenance and/or failure to correct any problems prior to operating this generator can cause a malfunction which could cause

death or serious injury. Always follow the inspection and maintenance recommendations and schedules in this manual.

Recommended Maintenance Schedule

Engine Oil Check Level

Each Use Every Month or

Each 20 Hrs

X

Air Filter Check

X

Every 3 Months or

Each 50 Hrs

Every 6 Months or

Each 100 Hrs

Every Year or

Each 300 Hrs

Clean X

Fuel Filler Cap Clean

Spark Plug

Fuel Tank

Check/Clean

Verify Gas Level

X

X

X

Clean X

Figure 7 - Recommended maintenance schedule

Cleaning the Generator

Always try to use this generator in a cool dry place. If this generator becomes dirty, the exterior can be cleaned with a damp cloth, soft brush, vacuum and/or pressurized air.

Never clean this generator with a bucket of water and/or a hose as water can get inside and cause a short circuit or corrosion.

Never use gasoline to clean parts of this generator.

GEN154A 2000 Surge Watts/1200 Running Watts Portable Generator 18

Checking the Oil Level

It is important to check the oil level in the engine crankcase before each use to ensure that there is a sufficient quantity.

To check the oil level:

1. Verify that this generator is shut down and on a level surface.

2. Unscrew the oil filler/dipstick cap from the engine.

3. With a dry cloth, wipe the oil off of the dipstick that is located on the inside of the cap.

4. Insert the dipstick as if replacing the cap and then remove again. There should be oil on the dipstick. If there is no oil on the dipstick, or oil is visible only at the very end of the dipstick, add oil until the engine crankcase is filled.

5. Confirm that the oil filler/dipstick cap is properly in place when finished verifying the oil level.

Changing/Adding Oil

The oil level in this generator should be checked before each use. (See Figure 9.) When the oil level is low, add oil until the level is sufficient to operate this generator.

The oil capacity for this Model GEN154A 2000 Surge Watts / 1200 Running Watts Portable Generator engine is 13.5 fluid oz. (0.40 L).

To drain the oil from this generator:

It is necessary to drain the oil from the crankcase only if it has become contaminated with water and/or dirt.

1. Place a bucket underneath this generator to catch oil as it drains.

2. Unscrew the oil drain plug located on the crankcase underneath the oil filler/dipstick cap.

3. Allow all the oil to drain from this generator.

4. Replace the oil drain plug and tighten.

NOTE: Never dispose of used motor oil in the trash, down a drain or on the ground. Put oil in a sealed container and contact your local recycling center or auto garage to arrange oil disposal.

To add oil to the engine crankcase:

1. Confirm that this generator is on a level surface.

2. Unscrew the oil filler/dipstick cap from the engine as illustrated in Figure 8 below.

3. Using a funnel, add high detergent motor oil to fill the engine crankcase to the correct quantity. SAE10W-30 oil is recommended for general use.

When the engine crankcase is full, the oil level should reach the lower lip of the oil filling opening as shown in Figure 8.

Oil Capacity (fluid oz./L)

Oil Type Recommended

13.5 / 0.40

High Detergent Motor Oil, SAE10W-30

GEN154A 2000 Surge Watts/1200 Running Watts Portable Generator

Figure 8 – Adding oil

19

Air Filter Maintenance

Routine maintenance of the air filter helps maintain proper airflow to the carburetor. Occasionally verify that the air filter is free of excessive dirt. The air filter will require more frequent cleaning when operating this generator in extremely dusty areas.

To clean air filter, remove from generator. Wash in kerosene. Pour motor oil on filter, squeeze out excess oil and reinstall in the generator.

Spark Plug Maintenance

The spark plug is essential for proper engine operation. The spark plug should be intact, free of deposits, and properly gapped. A bad or incorrectly installed spark plug can cause engine damage.

To inspect the spark plug:

1. Remove the spark plug by pulling on the spark plug cap.

2. Unscrew the spark plug from this generator by using the included spark plug wrench.

3. Visually inspect the spark plug. If it is cracked and/or chipped, discard and install a new spark plug. A E6TC spark plug, such as NGK

BP6HS

, is recommended.

4. Measure the spark plug electrode gap with a gauge. The gap should be 0.028-0.031in (0.7-0.8mm). (See Figure 9.)

5. If re-using the spark plug, use a wire brush to clean any dirt from around the spark plug base and then re-gap the spark plug.

6. Screw the spark plug back into place on this generator by using the included spark plug wrench.

7. Replace the spark plug cap.

Figure 9 - Measuring the spark plug gap

Emptying the Fuel Tank

To store this generator for extended time, drain the gasoline from the fuel tank.

To drain gasoline from this generator:

1. Turn the fuel valve to the “off” position.

2. Remove the fuel filter cup.

3. Empty the fuel filter cup of any fuel.

4. Place a receptacle underneath this generator to catch gasoline as it drains.

5. Turn the fuel valve to the “on” position and allow all gasoline to drain.

6. Turn the fuel valve to the “off” position.

7. Replace the fuel filter cup.

8. Store the drained gasoline in a suitable place.

Do not store gasoline for more than 3 months.

GEN154A 2000 Surge Watts/1200 Running Watts Portable Generator 20

STORAGE/TRANSPORT PROCEDURES

Never place any type of storage cover on this generator while it is still hot.

When transporting or storing this generator for extended time:

• Allow generator to fully cool before moving it. A hot engine and exhaust system can burn you and ignite some materials.

• Empty the fuel tank. (See “Emptying the Fuel Tank” in the “Maintenance/Care” section.)

• Turn the fuel valve to the “off” position.

• Disconnect the spark plug.

• Do not obstruct any ventilation openings.

• Do not drop or strike this generator while moving it.

• Store this generator in a cool dry area, free of excessive dust.

Storage Time

Less than 1 month

1 to 2 months

2 months to 1 year

1 year or more

Recommended Storage Procedure (which will help prevent difficult starts)

No storage procedure required.

Fill with fresh gasoline and add gasoline conditioner

Empty the fuel tank. (See “Emptying the Fuel Tank” in the “Maintenance/Care” section.)

Empty the fuel tank. (See “Emptying the Fuel Tank” in the “Maintenance/Care” section.)

Disconnect the spark plug.

TROUBLESHOOTING

IMPORTANT: If trouble persists, call our customer help line at

1-866-460-9436

, Monday - Friday, 8 AM - 4 PM Central Time.

Symptom Cause Solution

Engine will not start. Engine switch is set to "off." Set engine switch to "on."

Fuel valve is turned to "closed."

Choke is open.

Turn fuel valve to "open."

Close the choke.

Engine is out of gasoline.

Engine is filled with contaminated and/or old gasoline.

Add gasoline.

Drain gasoline from the engine and add new gasoline.

Engine runs but there is no electrical output.

Generator runs but does not support all connected electrical devices.

Spark plug is dirty.

Spark plug is broken.

Oil is low.

Circuit breaker is off.

Clean spark plug.

Replace spark plug.

Add or replace oil.

Flip circuit breaker to "on."

Reset button is "off."

Bad connecting wires/cables.

Bad electrical device connected to generator. Disconnect device, try connecting another device.

Generator is overloaded. Reduce draw on generator to within this generator's rated wattage by reducing number of connected electrical devices.

Short in one of the connected devices.

Push reset button to "on."

Try a different extension cord.

Air filter is dirty.

Disconnect any faulty or short-circuited electrical loads.

Clean or replace air filter.

GEN154A 2000 Surge Watts/1200 Running Watts Portable Generator 21

GEN154A 2000 SURGE WATTS / 1200 RUNNING WATTS PORTABLE GENERATOR

PARTS DIAGRAM

GEN154A 2000 Surge Watts/1200 Running Watts Portable Generator 22

GEN154A 2000 SURGE WATTS / 1200 RUNNING WATTS PORTABLE GENERATOR

PARTS LIST

GEN154A 2000 Surge Watts/1200 Running Watts Portable Generator 23

GEN154A201002

GEN154A 2000 Surge Watts/1200 Running Watts Portable Generator 24

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Frequently Answers and Questions

What is the starting mechanism of KingCraft GEN154A?
It starts with a recoil mechanism.
What is the fuel type required for KingCraft GEN154A?
Unleaded Gasoline is the recommended fuel for KingCraft GEN154A.
How many AC outlets does the KingCraft GEN154A have?
There are two 120-volt 60 Hz / 10 AMP AC outlets.
What is the continuous running wattage of the KingCraft GEN154A?
The continuous running wattage is 1200 watts.
How long does KingCraft GEN154A run at 50% load on a full tank?
At 50% load, the generator can run for about 11 hours with a full tank.
What is the engine speed of KingCraft GEN154A?
The engine runs at 3600 RPM.
Where do I find the customer service phone number?
You can reach customer service at 1-866-460-9436, Monday to Friday, 8 AM - 4 PM Central Time.
Is the generator EPA approved?
Yes, the KingCraft GEN154A is EPA approved.
What type of insulation does the generator have?
It features class F insulation.
What is the power factor of the generator?
The power factor is 1.0.
Download PDF