Asus P7F-M WS User guide

Add to my manuals
156 Pages

advertisement

Asus P7F-M WS User guide | Manualzz
RS100-E6/PI2
1U Rackmount Server
User Guide
E5109
First Edition
November 2009
Copyright © 2009 ASUSTeK COMPUTER INC. All Rights Reserved.
No part of this manual, including the products and software described in it, may be reproduced, transmitted,
transcribed, stored in a retrieval system, or translated into any language in any form or by any means,
except documentation kept by the purchaser for backup purposes, without the express written permission
of ASUSTeK COMPUTER INC. (“ASUS”).
ASUS provides this manual “as is” without warranty of any kind, either express or implied, including but not
limited to the implied warranties or conditions of merchantability or fitness for a particular purpose. In no
event shall ASUS, its directors, officers, employees, or agents be liable for any indirect, special, incidental,
or consequential damages (including damages for loss of profits, loss of business, loss of use or data,
interruption of business and the like), even if ASUS has been advised of the possibility of such damages
arising from any defect or error in this manual or product.
Specifications and information contained in this manual ae furnished for informational use only, and are
subject to change at any time without notice, and should not be construed as a commitment by ASUS.
ASUS assumes no responsibility or liability for any errors or inaccuracies that may appear in this manual,
including the products and software described in it.
Product warranty or service will not be extended if: (1) the product is repaired, modified or altered, unless
such repair, modification of alteration is authorized in writing by ASUS; or (2) the serial number of the
product is defaced or missing.
Products and corporate names appearing in this manual may or may not be registered trademarks or
copyrights of their respective companies, and are used only for identification or explanation and to the
owners’ benefit, without intent to infringe.
ii
Contents
Contents....................................................................................................... iii
Notices......................................................................................................... vii
Safety information..................................................................................... viii
About this guide.......................................................................................... ix
Chapter 1:
Product introduction
1.1
System package contents............................................................ 1-2
1.3
System specifications.................................................................. 1-3
1.2
Serial number label....................................................................... 1-2
1.4
Front panel features...................................................................... 1-5
1.6
Internal features............................................................................ 1-6
1.5
1.7
Rear panel features....................................................................... 1-5
LED information............................................................................ 1-7
1.7.1
1.7.2
Chapter 2:
2.1
2.2
2.3
2.5
2.6
2.7
LAN (RJ-45) LEDs........................................................... 1-7
Hardware setup
Chassis cover................................................................................ 2-2
2.1.1
2.1.2
Removing the chassis cover............................................ 2-2
Reinstalling the chassis cover.......................................... 2-3
Central Processing Unit (CPU).................................................... 2-5
2.2.1
2.2.2
Installing the CPU............................................................ 2-5
Installing the CPU heatsink and airduct........................... 2-8
System memory.......................................................................... 2-10
2.3.1
Overview........................................................................ 2-10
2.3.3
Installing a DIMM............................................................2-11
2.3.2
2.4
Front panel LEDs............................................................. 1-7
2.3.4
Memory Configurations.................................................. 2-10
Removing a DIMM..........................................................2-11
Hard disk drives.......................................................................... 2-12
2.4.1
2.4.2
Installing a hard disk drive to the HDD tray 1................. 2-12
Installing a hard disk drive to the HDD tray 2................. 2-13
Expansion card........................................................................... 2-15
2.5.1
2.5.2
Installing an expansion card.......................................... 2-15
Configuring an expansion card...................................... 2-17
Cable connections...................................................................... 2-18
Removable/optional components.............................................. 2-19
2.7.1
System fans................................................................... 2-19
iii
Contents
2.7.2
2.7.3
Chapter 3:
Rackmount installation
3.1
Rackmount rail kit items............................................................... 3-2
3.3
Attaching the rails to the rack...................................................... 3-3
3.2
Attaching the rack ears................................................................ 3-2
Chapter 4:
Motherboard Info
4.1
Motherboard layout....................................................................... 4-2
4.3
Internal connectors....................................................................... 4-8
4.2
Jumpers......................................................................................... 4-4
Chapter 5:
5.1
5.2
5.1.1
ASUS EZ Flash 2 utility.................................................... 5-2
5.1.3
ASUS CrashFree BIOS 3 utility....................................... 5-5
5.2.1
BIOS menu screen........................................................... 5-7
5.2.3
Navigation keys................................................................ 5-7
5.2.4
5.2.5
5.2.6
5.2.7
5.2.8
5.2.9
Menu bar.......................................................................... 5-7
Menu items...................................................................... 5-8
Sub-menu items............................................................... 5-8
Configuration fields.......................................................... 5-8
Pop-up window................................................................ 5-8
Scroll bar.......................................................................... 5-8
General help.................................................................... 5-8
Main menu..................................................................................... 5-9
5.3.1
5.3.2
5.3.3
System Time [xx:xx:xx].................................................... 5-9
System Date [Day xx/xx/xxxx].......................................... 5-9
SATA1—6......................................................................... 5-9
5.3.4
Storage Configuration.....................................................5-11
5.3.6
System Information........................................................ 5-13
5.3.5
5.4
BUPDATER utility............................................................ 5-3
BIOS setup program..................................................................... 5-6
5.2.2
5.3
BIOS setup
Managing and updating your BIOS............................................. 5-2
5.1.2
iv
Optical disk drive (ODD)................................................ 2-20
Installing ASMB4 series management board (optional)....2-22
AHCI Configuration........................................................ 5-12
Advanced menu.......................................................................... 5-14
5.4.1
CPU Configuration......................................................... 5-14
Contents
5.4.2
Chipset........................................................................... 5-18
5.4.4
USB Configuration......................................................... 5-21
5.4.3
5.4.5
5.4.6
5.4.7
5.4.8
5.5
5.6
5.7
5.4.9
5.9
5.6.1
5.6.2
Event Log Configuration................................................ 5-25
Intel VT-d Configuration [Disabled]................................ 5-25
SR-IOV Supprted [Disabled].......................................... 5-25
APM Configuration......................................................... 5-28
Hardware Monitor.......................................................... 5-30
Boot menu................................................................................... 5-31
5.7.1
Boot Device Priority....................................................... 5-31
5.7.3
Boot Settings Configuration........................................... 5-32
5.7.4
Hard Disk Drives; CDROM Drives................................. 5-31
Security.......................................................................... 5-33
Tools menu.................................................................................. 5-35
5.8.1
ASUS EZ Flash 2........................................................... 5-35
Exit menu..................................................................................... 5-36
RAID configuration
Setting up RAID............................................................................. 6-2
6.1.1
RAID definitions............................................................... 6-2
6.1.3
RAID controller selection................................................. 6-3
6.1.2
6.2
ACPI Configuration........................................................ 5-23
Power menu................................................................................. 5-28
Chapter 6:
6.1
PCIPnP.......................................................................... 5-22
Server menu................................................................................ 5-26
5.7.2
5.8
Onboard Devices Configuration..................................... 5-20
6.1.4
Installing hard disk drives................................................. 6-2
Setting the RAID item in BIOS......................................... 6-3
LSI Software RAID Configuration Utility..................................... 6-4
6.2.1
Creating a RAID set......................................................... 6-5
6.2.3
Initializing the virtual drives............................................ 6-12
6.2.2
6.2.4
6.2.5
6.2.6
6.2.7
6.2.8
Adding or viewing a RAID configuration.........................6-11
Rebuilding failed drives.................................................. 6-16
Checking the drives for data consistency...................... 6-18
Deleting a RAID configuration........................................ 6-21
Selecting the boot drive from a RAID set....................... 6-22
Enabling WriteCache..................................................... 6-23
Contents
6.3Intel® Matrix Storage Manager Option ROM Utility.................. 6-24
6.3.1
Creating a RAID set....................................................... 6-25
6.3.3
Deleting a RAID set....................................................... 6-28
6.3.2
6.3.4
6.3.5
6.3.6
6.3.7
6.3.8
Chapter 7:
7.1
7.2
7.3
7.4
Creating a Recovery set................................................ 6-26
Resetting disks to Non-RAID......................................... 6-29
Recovery Volume Options............................................. 6-30
Exiting the Intel® Matrix Storage Manager..................... 6-31
Rebuilding the RAID...................................................... 6-31
Setting the Boot array in the BIOS Setup Utility............. 6-33
Driver installation
RAID driver installation................................................................ 7-2
7.1.1
7.1.2
Creating a RAID driver disk............................................. 7-2
Installing the RAID controller driver................................. 7-5
Intel® chipset device installation............................................... 7-17
LAN driver installation................................................................ 7-19
VGA driver installation............................................................... 7-22
7.5Management applications and utilities installation................. 7-24
7.5.1
Running the support DVD.............................................. 7-24
7.5.3
Utilities menu................................................................. 7-25
7.5.2
7.5.4
7.5.5
vi
Drivers menu.................................................................. 7-24
Make disk menu............................................................. 7-25
Contact information........................................................ 7-25
Notices
Federal Communications Commission Statement
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions:
• This device may not cause harmful interference, and
• This device must accept any interference received including interference that
may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class
A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed
to provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses and can radiate radio frequency
energy and, if not installed and used in accordance with manufacturer’s instructions,
may cause harmful interference to radio communications. However, there is
no guarantee that interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television reception, which
can be determined by turning the equipment off and on, the user is encouraged to
try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment to an outlet on a circuit different from that to which the
receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
WARNING! The use of shielded cables for connection of the monitor to the
graphics card is required to assure compliance with FCC regulations. Changes
or modifications to this unit not expressly approved by the party responsible for
compliance could void the user’s authority to operate this equipment.
Canadian Department of Communications Statement
This digital apparatus does not exceed the Class B limits for radio noise emissions
from digital apparatus set out in the Radio Interference Regulations of the
Canadian Department of Communications.
This Class B digital apparatus complies with Canadian ICES-003.
REACH
Complying with the REACH (Registration, Evaluation, Authorization, and Restriction
of Chemicals) regulatory framework, we publish the chemical substances in our
products at ASUS REACH website at http://green.asus.com/english/REACH.htm.
vii
Safety information
Electrical Safety
•
•
•
•
Before installing or removing signal cables, ensure that the power cables for
the system unit and all attached devices are unplugged.
To prevent electrical shock hazard, disconnect the power cable from the
electrical outlet before relocating the system.
When adding or removing any additional devices to or from the system, contact
a qualified service technician or your dealer. Ensure that the power cables for
the devices are unplugged before the signal cables are connected. If possible,
disconnect all power cables from the existing system before you service.
If the power supply is broken, do not try to fix it by yourself. Contact a qualified
service technician or your dealer.
Operation Safety
•
•
•
•
•
Servicing of this product or units is to be performed by trained service
personnel only.
Before operating the server, carefully read all the manuals included with the
server package.
Before using the server, make sure all cables are correctly connected and the
power cables are not damaged. If any damage is detected, contact your dealer
as soon as possible.
To avoid short circuits, keep paper clips, screws, and staples away from
connectors, slots, sockets and circuitry.
Avoid dust, humidity, and temperature extremes. Place the server on a stable
surface.
This product is equipped with a three-wire power cable and plug for the user’s
safety. Use the power cable with a properly grounded electrical outlet to avoid
electrical shock.
Lithium-Ion Battery Warning
CAUTION! Danger of explosion if battery is incorrectly replaced. Replace
only with the same or equivalent type recommended by the manufacturer.
Dispose of used batteries according to the manufacturer’s instructions.
CD-ROM Drive Safety Warning
CLASS 1 LASER PRODUCT
Heavy System
CAUTION! This server system is heavy. Ask for assistance when moving or
carrying the system.
viii
DO NOT throw the motherboard in municipal waste. This product has been
designed to enable proper reuse of parts and recycling. This symbol of the
crossed out wheeled bin indicates that the product (electrical and electronic
equipment) should not be placed in municipal waste. Check local regulations for
disposal of electronic products.
DO NOT throw the mercury-containing button cell battery in municipal waste.
This symbol of the crossed out wheeled bin indicates that the battery should not
be placed in municipal waste.
About this guide
Audience
This user guide is intended for system integrators, and experienced users with at
least basic knowledge of configuring a server.
Contents
This guide contains the following parts:
1.
2.
3.
4.
5.
6.
7
Chapter 1: Product Introduction
This chapter describes the general features of the server, including sections
on front panel and rear panel specifications.
Chapter 2: Hardware setup
This chapter lists the hardware setup procedures that you have to perform
when installing or removing system components.
Chapter 3: Rackmount installation
This chapter describes how to install the rackmount rail kit to the barebone
server
Chapter 4: Motherboard information
This chapter includes the motherboard layout and brief descriptions of the
jumpers and internal connectors.
Chapter 5: BIOS information
This chapter tells how to change system settings through the BIOS Setup
menus and describes the BIOS parameters.
Chapter 6: RAID configuration
This chapter provides instructions for setting up, creating and configuring
RAID sets using the available utilities.
Chapter 7: Driver installation
This chapter provides instructions for installing the necessary drivers for
different system components.
ix
Conventions
To make sure that you perform certain tasks properly, take note of the following
symbols used throughout this manual.
DANGER/WARNING: Information to prevent injury to yourself when
trying to complete a task.
CAUTION: Information to prevent damage to the components when
trying to complete a task.
IMPORTANT: Instructions that you MUST follow to complete a task.
NOTE: Tips and additional information to help you complete a task.
Typography
Bold text
Indicates a menu or an item to select.
Italics <Key> Used to emphasize a word or a phrase.
Example: <Enter> means that you must press
the Enter or Return key.
<Key1+Key2+Key3>
If you must press two or more keys simultaneously, the key names are linked with a plus sign (+).
Example: <Ctrl+Alt+D>
Command
Means that you must type the command exactly
as shown, then supply the required item or value
enclosed in brackets.
Example: At the DOS prompt, type the
command line: format A:/S
Keys enclosed in the less-than and greater-than sign means that you must press the enclosed key.
References
Refer to the following sources for additional information, and for product and
software updates.
1.
2.
ASUS Server Web-based Management (ASWM) user guide
This manual tells how to set up and use the proprietary ASUS server
management utility.
ASUS websites
The ASUS websites worldwide provide updated information for all ASUS
hardware and software products. Refer to the ASUS contact information.
This chapter describes the general
features of the server, including
sections on front panel and rear panel
specifications.
Product introduction
Chapter 1
1.1
System package contents
Check your system package for the following items.
Model Name RS100-E6/PI2
Chassis
ASUS R09 1U Rackmount Chassis
Motherboard ASUS P7F-M Server Board
Component
1 x 220W Single Power Supply
2 x SATA Cables
1 x PCI Express x16 Riser Card (PCIE16-R11)
1 x Front I/O Board (FPB-R9)
1 x USB Board (USB-R9)
2 x System Fans (40mm x 28mm)
Accessories
1 x RS100-E6/PI2 User’s Guide
1 x ASUS ASWM 2.0 User’s Guide
1 x RS100-E6/PI2 Support CD (including ASWM*)
1 x Bag of Screws
1 x AC Power Cable
Optional
Items
CPU Heatsink
Riser Card: PCI 32bit/33MHz (R133-R9A)
ASUS ASMB4-iKVM Remote management card
Slim-type Optical Device
Ball Bearing Rail Kit
CA eTrust Anti-virus Software CD
*ASUS System Web-based Management
If any of the above items is damaged or missing, contact your retailer.
1.2
Serial number label
Before requesting support from the ASUS Technical Support team, you must
take note of the product’s serial number containing 14 characters such as
xxS0xxxxxxxxxx shown as the figure below. With the correct serial number of the
product, ASUS Technical Support team members can then offer a quicker and
satisfying solution to your problems.
RS100-E6/PI2
xxS0xxxxxxxxxx
1-2
Chapter 1: Product introduction
1.3
System specifications
The ASUS RS100-E6/PI2 is a 1U barebone server system featuring the ASUS
P7F-M server board. The server supports Intel® LGA1156 Lynnfield / Clarkdale
processors, plus other latest technologies through the chipsets onboard.
Model Name
Processor / System Bus
Core Logic
ASUS Features
Smart Fan
ASWM2.0
Total Slots
Capacity
Memory
Memory Type
Memory Size
Expansion
Slots
Total PCI/PCI-X/
PCI-E Slots
Slot Type
Storage
HDD Bays
Networking
Graphic
I = internal
A or S = hotswappable
LAN
VGA
1
1 x PCI-E 2.0 x16 slot (x16 link) (Full-Height/HL)
2 x SATA2 300MB/s ports
Intel® Matrix Storage (for Windows only)
- Supports software RAID 0 & 1
LSI® MegaRAID (for Linux / Windows)
- Supports software RAID 0 & 1
2 x Internal 3.5” SATA2 HDD Bays
Auxiliary Storage FDD / CD / DVD
Onboard I/O
RS100-E6/PI2
1 x Socket LGA1156
Quad Core Intel® Xeon 3400 series Server Processor
Quad Core Intel® Core i7-800 series Desktop Processor
Quad Core Intel® Core i5-700 series Desktop Processor
Dual Core Clarkdale CPU design Ready
Intel® 3420 PCH
√
√
4 (2 Channels)
Maximum up to 32GB (RDIMM)
Maximum up to 16GB (UDIMM )
Desktop Processor do not support RDIMM nor
ECC UDIMM
DDR3 1333 / 1066 Registered / Unbuffered DIMM with ECC / Non ECC
1 GB, 2GB, 4GB, 8GB (RDIMM)
1 GB, 2GB, 4GB (UDIMM)
2 x Intel® 82574L + 1 x Mgmt LAN
Aspeed® AST2050 8MB
1 x Slim-type Optical Device Bay
(Options: No ODD / DVD-ROM / DVD-RW)
1 x External Serial Port
3 x RJ-45 ports (1 for ASMB4-iKVM)
4 x USB 2.0 ports (Front x 2, Rear x 2)
1 x VGA port
1 x PS/2 keyboard port
1 x PS/2 mouse port
(continued on the next page)
ASUS RS100-E6/PI2
1-3
OS Support
Anti-virus Software
Out of Band
Remote
Management
Hardware
Solution
Software
Net Weight Kg (CPU, DRAM &
HDD not inclu ded)
Dimension (DD x WW x HH)
Power Supply
Power Rating
Environment
Windows® Server 2008 Enterprise 32 / 64-bit
Windows® Server 2003 R2 Enterprise 32 / 64-bit
RedHat® Enterprise Linux AS5.0 32 / 64-bit
SuSE® Linux Enterprise Server 10 32 / 64-bit
(Subject to change without any notice)
Optional anti-virus CD Pack
Optional ASMB4-iKVM for KVM-over-IP support
ASUS ASWM 2.0®
6.5 Kg
380mm x 429.6mm x 43.2mm
220W Single Power Supply
Input: 100-240Vac, 4-2A, 50-60Hz, Class I
Operation temperature: 10°C–35°C / Non operation
temperature: -40°C–70°C
Non operation humidity: 20%–90%
( Non-condensing)
*Specifications are subject to change without notice.
1-4
Chapter 1: Product introduction
1.4
Front panel features
The barebone server displays a simple yet stylish front panel with easily accessible
features. The power and reset buttons, LED indicators, optical drive, and twp USB
ports are located on the front panel.
Refer to section 1.7.1 Front panel LEDs for the LED descriptions.
USB 2.0 ports
HDD Access LED
LAN2 LED
LAN1 LED
Power LED
Optical drive
Power button
Reset button
Turn off the system power and detach the power supply before removing or
replacing any system component.
1.5
Rear panel features
The rear panel includes the expansion slot and system power socket. The I/O
shield with openings for the rear panel connectors on the motherboard are also
placed in the rear panel.
Expansion slot
LAN port 1
LAN port 2
VGA port
Serial port
LAN port 3*
USB 2.0 ports
PS/2 keyboard port
PS/2 mouse port
AC power socket
•
The ports for the PS/2 keyboard, PS/2 mouse, USB, VGA, and Gigabit LAN
do not appear on the rear panel if motherboard is not present.
•
*The port is for ASUS ASMB4-iKVM controller card only.
ASUS RS100-E6/PI2
1-5
1.6
Internal features
The barebone server includes the basic components as shown.
1
4
3
6
5
2
1.
PCI Express x16 Riser Card (at x16 link)
3.
ASUS P7F-M Server Board
2.
4.
5.
6.
System Fan (x2) (9GV0412P3J051)
Power Supply
HDD Tray 2 (hidden) and Slim-type Optical
Drive (optional)
HDD Tray 1
Turn off the system power and detach the power supply before removing or
replacing any system component.
The barebone server does not include a floppy disk drive. Connect a USB floppy
disk drive to any of the USB ports on the front or rear panel if you need to use a
floppy disk.
*WARNING
HAZARDOUS MOVING PARTS
KEEP FINGERS AND OTHER BODY PARTS AWAY
1-6
Chapter 1: Product introduction
1.7
LED information
1.7.1
Front panel LEDs
HDD Access LED
LAN2 LED
LED
LAN1 LED
Display status
Description
Power LED
ON
System power ON
HDD Access LED
OFF
Blinking
No activity
Read/write data into the HDD
LAN LEDs
OFF
Blinking
ON
No LAN connection
LAN is transmitting or receiving data
LAN connection is present
1.7.2
Icon
Power LED
LAN (RJ-45) LEDs
SPEED LED
ACT/LINK LED
ACT/LINK LED
Status
Description
OFF
No link
GREEN
Linked
BLINKING
Data activity
ASUS RS100-E6/PI2
Status
OFF
ORANGE
GREEN
SPEED LED
Description
10 Mbps connection
100 Mbps connection
1 Gbps connection
1-7
1-8
Chapter 1: Product introduction
This chapter lists the hardware setup
procedures that you have to perform
when installing or removing system
components.
Hardware setup
Chapter 2
2.1
Chassis cover
2.1.1
Removing the chassis cover
•
Ensure that you unplug the power cord before removing the chassis cover.
•
Take extra care when removing the chassis cover. Keep your fingers from
components inside the chassis that can cause injury, such as the CPU fan,
rear fan, and other sharp-edged parts.
•
The images of the barebone server shown in this section are for reference
purposes only and may not exactly match the model you purchase.
To remove the chassis cover:
2-2
1.
Use a Phillips screwdriver to remove the three screws on the chassis cover.
2.
Firmly hold the cover and
slide it toward the rear
panel for about half an inch
until it is disengaged from
the chassis.
3.
Lift the cover from the chassis.
Chapter 2: Hardware setup
2.1.2
Reinstalling the chassis cover
To reinstall the chassis cover:
1.
Position the cover on top of the chassis with the hooks aligned to the side
tabs of the chassis.
Side tabs
2.
Slide the cover toward the front until it snaps in place.
ASUS RS100-E6/PI2
2-3
3.
2-4
Secure the cover with three screws.
Chapter 2: Hardware setup
2.2
Central Processing Unit (CPU)
The motherboard comes with a surface mount LGA 1156 Socket designed for the
Intel® Lynnfield / Clarkdale series processors.
Ensure that all power cables are unplugged before installing the CPU.
2.2.1
•
Upon purchase of the motherboard, ensure that the PnP cap is on
the socket and the socket contacts are not bent. Contact your retailer
immediately if the PnP cap is missing, or if you see any damage to the PnP
cap/socket contacts/motherboard components. ASUS shoulders the repair
cost only if the damage is shipment/transit-related.
•
Keep the cap after installing the motherboard. ASUS will process Return
Merchandise Authorization (RMA) requests only if the motherboard comes
with the cap on the LGA1156 socket.
•
The product warranty does not cover damage to the socket contacts
resulting from incorrect CPU installation/removal, or misplacement/loss/
incorrect removal of the PnP cap.
Installing the CPU
To install a CPU:
1.
Locate the CPU socket on the motherboard.
2.
Press the load lever with your
thumb (A), and then move it to the
right (B) until it is released from the
retention tab.
To prevent damage to the socket
pins, do not remove the PnP cap
unless you are installing a CPU.
ASUS RS100-E6/PI2
Load lever
A
B
Retention tab
2-5
3.
Lift the load lever in the direction
of the arrow until the load plate is
completely lifted.
Load plate
4.
5.
Remove the PnP cap from the CPU
socket.
PnP cap
Position the CPU over the socket,
ensuring that the gold triangle is on
the bottom‑left corner of the socket,
and then fit the socket alignment
keys into the CPU notches.
The CPU fits in only one correct
orientation. DO NOT force the
CPU into the socket to prevent
bending the connectors on the
socket and damaging the CPU!
CPU notches
Gold
triangle
mark
Alignment keys
2-6
Chapter 2: Hardware setup
6.
Apply some Thermal Interface
Material to the exposed area of
the CPU that the heatsink will be
in contact with, ensuring that it is
spread in an even thin layer.
Some heatsinks come with preapplied thermal paste. If so, skip
this step.
The Thermal Interface Material is
toxic and inedible. DO NOT eat it.
If it gets into your eyes or touches
your skin, wash it off immediately,
and seek professional medical
help.
7.
Close the load plate (A), and then
push down the load lever (B),
ensuring that the front edge of the
load plate slides under the retention
lock (C).
B
A
C
8.
Insert the load lever under the
retention tab.
ASUS RS100-E6/PI2
2-7
2.2.2
Installing the CPU heatsink and airduct
To install the CPU heatsink:
1.
Lift one side of the mylar and set it
aside for installing the CPU heatsink.
2.
Remove the protection sticker on
the back of the CPU heatsink.
Protection sticker
3.
2-8
Place the heatsink on top of the
installed CPU, ensuring that the
four fasteners match the holes on
the motherboard.
Chapter 2: Hardware setup
4.
Twist each of the four screws with
a Philips (cross) screwdriver just
enough to attach the heatsink to
the motherboard. When the four
screws are attached, tighten them
one by one to completely secure
the heatsink.
A
B
B
A
Tighten the four heatsink screws in a diagonal
sequence.
5.
Secure the heat pipe and air duct
to the server with two screws.
6.
Set the mylar back to its original
place. When the mylar is properly
installed, the hook as shown below
should attach the motherboard edge.
Ensure that the mylar does not interfere any motherboard headers or capacitors.
ASUS RS100-E6/PI2
2-9
2.3
System memory
2.3.1
Overview
The motherboard comes with four Double Data Rate 3 (DDR3) Dual Inline Memory
Modules (DIMM) sockets.
The figure illustrates the location of the DDR3 DIMM sockets:
2.3.2
Memory Configurations
You may install 1 GB, 2 GB, 4 GB, 8 GB Registerd, or 1 GB, 2 GB, 4 GB
Unbuffered with ECC/Non-ECC DDR3 DIMMs into the DIMM sockets using the
memory configurations in this section.
UDIMM
DIMM Slot
Per Channel
2
2
2-10
DIMM Populated DIMM Type
per Channel
1
Unbuffered DDR3
2
Unbuffered DDR3
Speed
Rank per DIMM
1333
1333
Single Rank, Dual Rank
Single Rank, Dual Rank
•
Always install DIMMs with the same CAS latency. For optimum
compatibility, it is recommended that you obtain memory modules from the
same vendor.
•
The motherboard supports x8 DRAM only and x4 & x16 DRAM are not
supported
Chapter 2: Hardware setup
2.3.3
Installing a DIMM
Ensure to unplug the power supply before adding or removing DIMMs or other
system components. Failure to do so may cause severe damage to both the
motherboard and the components.
1.
2.
2
Unlock a DIMM socket by pressing
the retaining clips outward.
DIMM notch
Align a DIMM on the socket
such that the notch on the DIMM
matches the break on the socket.
1
1
Unlocked retaining clip
A DIMM is keyed with a notch so that it fits in only one direction. DO NOT force
a DIMM into a socket to avoid damaging the DIMM.
3.
Firmly insert the DIMM into the
socket until the retaining clips snap
back in place and the DIMM is
properly seated.
3
Locked Retaining Clip
2.3.4
Removing a DIMM
Follow these steps to remove a DIMM.
1.
Simultaneously press the
retaining clips outward to unlock
the DIMM.
2
1
1
Support the DIMM lightly with your fingers when pressing the retaining clips.
The DIMM might get damaged when it flips out with extra force.
2.
Remove the DIMM from the socket.
ASUS RS100-E6/PI2
2-11
2.4
Hard disk drives
You can install up to two (2) Serial ATA hard disk drives to the system. Follow the
succeeding instructions to install each of the drives.
2.4.1
Installing a hard disk drive to the HDD tray 1
To install a hard disk drive to the HDD tray 1:
1.
Locate the HDD tray 1 beside the
power supply unit. Notice the four
standard screw holes.
2.
Connect the SATA signal cable and
a power plug from the power supply
to the hard disk drive.
Use the L-type SATA connector
to connect to the hard disk drive.
L-type SATA
connector
Power plug
3.
2-12
SATA signal cable
Place the hard disk drive into the
HDD tray 1 matching the four screw
holes with the holes on the disk
drive.
Chapter 2: Hardware setup
4.
Secure the hard disk drive with four
screws.
2.4.2
Installing a hard disk drive to the HDD tray 2
To install a hard disk drive to the HDD tray 2:
1.
2.
If you have an ODD installed,
remove the ODD first before
installing a hard disk drive to the
HDD tray 2.
Disconnect the ODD cable, and then
use a screwdriver to remove the two
screws as shown.
Remove the four screws to release
the HDD bracket under the optical
disk drive.
HDD bracket
ASUS RS100-E6/PI2
2-13
3.
Insert the hard disk drive into the
HDD bracket and secure it with four
screws.
4.
Connect the SATA signal cable and
a power plug from the power supply
to the hard disk drive.
Use the L-type SATA connector
to connect to the hard disk drive.
L-type SATA
connector
2-14
Power plug
SATA signal cable
5.
Place the HDD bracket with the
hard disk drive installed into the
HDD tray 2, matching the four
screw holes. Then, secure the HDD
bracket with four screws.
6.
Refer to section 2.7.2 Optical disk drive (ODD) to reinstall the ODD.
Chapter 2: Hardware setup
2.5
Expansion card
The system comes with a riser card. You need to remove the riser card and the
expansion slot bracket if you want to install an expansion card.
Ensure to unplug the power cord before installing or removing an expansion
card. Failure to do so may cause severe damage to the motherboard and other
system components!
2.5.1
Installing an expansion card
To install an expansion card:
1.
Hold the riser card and pull it up to
detach it from the PCI Express slot
on the motherboard.
2.
Remove the screw to release the
expansion card bracket from the
system.
3.
Remove the screw to release the
metal slot cover from the expansion
card bracket.
ASUS RS100-E6/PI2
2-15
4.
Install the expansion card to the
riser card as shown.
5.
Attach the expansion card to the
expansion card bracket, and then
secure the card with a screw.
6.
Align the riser card with the
expansion card installed to the PCI
Express slot on the motherboard.
7.
8.
2-16
Press the riser card until the golden
connectors completely fit the slot
and the bracket aligns with the rear
panel.
Secure the expansion card bracket
to the system with one screw.
Chapter 2: Hardware setup
2.5.2
Configuring an expansion card
After installing the expansion card, configure the it by adjusting the software settings.
1.
2.
3.
Turn on the system and change the necessary BIOS settings, if any. See
Chapter 5 for information on BIOS setup.
Assign an IRQ to the card. Refer to the following tables.
Install the software drivers for the expansion card.
Standard Interrupt assignments
IRQ
Priority
Standard function
1
2
Keyboard Controller
0
2
3*
4*
5*
6
7*
8
9*
10*
11*
12*
13
14*
15*
1
-
11
12
13
14
15
3
4
5
6
7
8
9
10
System Timer
Programmable Interrupt
Communications Port (COM2)
Communications Port (COM1)
--
Floppy Disk Controller
--
System CMOS/Real Time Clock
ACPI Mode when used
IRQ Holder for PCI Steering
IRQ Holder for PCI Steering
PS/2 Compatible Mouse Port
Numeric Data Processor
Primary IDE Channel
Secondary IDE Channel
* These IRQs are usually available for ISA or PCI devices.
ASUS RS100-E6/PI2
2-17
2.6
Cable connections
•
The bundled system cables are pre-connected before shipment. You do
not need to disconnect these cables unless you will remove pre‑installed
components to install additional devices.
•
Refer to Chapter 4 for detailed information on the connectors.
1
3
2
3
3
4
5
6
Standard cables connected to the motherboard
1.
24-pin ATX power connector (from power supply to motherboard)
3.
System fan connector (from system fan to motherboard)
2.
4.
5.
6.
2-18
8-pin ATX 12V power connector (from power supply to motherboard)
SATA conectors (system default; from motherboard to SATA devices)
USB connector (from motherboard to front I/O board)
System panel connectors (from motherboard to front I/O board)
Chapter 2: Hardware setup
2.7
Removable/optional components
You may need to remove previously installed system components when installing
or removing system devices. Or you may need to install the optional components
into the system. This section tells how to remove/install the following components:
1.
System fans
3.
ASUS ASMB4-iKVM (optional)
2.
Optical disk drive (optional)
Ensure that the system is turned off before removing any components.
2.7.1
System fans
To remove the system fan:
1.
Unplug the system fan cables from
the FRNT_FAN1 and FRNT_FAN2
connectors on the motherboard.
2.
Locate and remove the two system
fan screws. Keep the screws for
late use.
3.
Remove the system fans, and then
set them aside.
Follow the previous instructions
in reverse if you want to reinstall
the system fans.
ASUS RS100-E6/PI2
2-19
2.7.2
Optical disk drive (ODD)
To install the optical disk drive:
1.
Slide in the optical disk drive into the
drive slot as shown.
Optical disk drive slot
2.
Align the screw hole of the ODD
bracket with the one on the HDD
bracket, and then secure it with a
screw.
ODD bracket
Optical disk drive (optional)
3.
Attach the ODD side bracket to the
ODD, matching the two connectors
of the bracket with the holes on the
side of the ODD.
Bracket
connectors
ODD side bracket
2-20
Chapter 2: Hardware setup
4.
Secure the ODD side bracket to the
HDD bracket with a screw.
5.
Connect the ODD cable to the
optical disk drive.
ASUS RS100-E6/PI2
2-21
2.7.3
Installing ASMB4 series management board (optional)
Follow the steps below to install an optional ASMB4 series management board on
your motherboard.
1.
Locate the BMC_FW1 header on
the motherboard.
2.
Orient and press the ASMB4
management card in place.
3.
Insert the LAN cable plug to
the LAN port 3 (dedicated
LAN) or LAN port 1 (shared
LAN) for server management.
LAN port 3
2-22
LAN port 1
Chapter 2: Hardware setup
This chapter describes how to install
the rackmount rail kit to the barebone
server.
Rackmount installation
Chapter 3
2-
3.1
Rackmount rail kit items
The rackmount rail kit contains two pairs of rails (one pair for each side of the
server system), six (6) pieces of inner rail screws, and two (2) pieces of rack
screws.
Outer rails
Inner rails
Rack screws
3.2
Inner rail screws
Attaching the rack ears
The bundled rack ears serve as handle when inserting or pulling the server from a
rack cabinet.
To attach rack ears:
1.
Prepare the bundled pair of rack ears and set of eight (8) screws.
Pair of rack ears
3-2
Chapter 3: Rackmount installation
2.
Locate the four screw holes on
each front-side of the chassis.
Select one side for installation.
3.
Get one rack ear and match the
four screw holes to the screw holes
on the chassis. Orient the rack ear
as shown.
4.
5.
Secure the rack ear to the chassis
with four screws.
Repeat steps 2 - 4 to attach the
other rack ear.
3.3
Attaching the rails to the rack
To attach the rack rails:
1.
Attach the inner rail to the correspoding side of the chassis and secure with
three inner rail screws. Make sure the rail is oriented as shown.
ASUS RS100-E6/PI2
3-3
2.
Attach the second inner rail to the other side of the chassis and secure with
three inner rail screws.
3.
Select one unit of space (1U) on
the rack where you wish to install
the server.
4.
Place three (3) nuts on the front
and three at the back. Do the same
to the corresponding side of the
rack.
Nuts
5.
Adjust the length of the outer rail
to fit the length of the rack cabinet,
then fasten the two screws.
6.
Secure the outer rail with two
screws at the front and rear of the
rack cabinet .
7.
3-4
Find the corresponding 1U space
on the other side of the rack cabinet
then repeat steps 5 and 6 to attach
the other outer rail.
Chapter 3: Rackmount installation
8.
Firmly hold the server on both sides. Slide the latches on the inner rack rails
to the direction indicated below. Hold the latches, and insert the rear side of
the server to the front end of the outer rack rail.
Make sure that the inner rails are properly aligned with the outer rails.
ASUS RS100-E6/PI2
3-5
9.
Carefully push the server all the way to the back until the front panel fits the
front end of the rack.
10. Secure the server to the rack with
one rack screw at one side. Secure
the other side as well.
Rack screw
3-6
Chapter 3: Rackmount installation
This chapter includes the motherboard
layout and brief descriptions of the
jumpers and internal connectors.
Motherboard Info
Chapter 4
4.1
4-2
Motherboard layout
Chapter 4: Motherboard information
Layout contents
Jumpers
Page
1.
Clear RTC RAM (CLRTC1)
4-4
2.
VGA controller setting (3-pin VGA_SW1)
4-5
3.
CPU Fan and Chassis Fan control setting (3-pin CPUFAN_SEL1,
CHAFAN_SEL1)
4-5
4.
LAN controller setting (3-pin LAN_SW1, LAN_SW2)
4-6
5.
RAID configuration utility selection (3-pin RAID_SEL1)
4-6
6.
Force BIOS recovery setting (3-pin RECOVERY1)
4-7
Internal connectors
Page
1.
Serial ATA connectors (7-pin SATA1–4 [Red], SATA5–6 [Black])
4-8
2.
Hard disk activity LED connector (4-pin HDLED1)
4-8
3.
USB connector (10-1 pin USB34, USB56; A-Type USB7)
4-9
4.
CPU, front and rear fan connectors (4-pin CPU_FAN1,
FRNT_FAN1, FRNT_FAN2, FRNT_FAN3, REAR_FAN1)
4-9
5.
Serial General Purpose Input/Output connector (6-1 pin SGPIO1)
4-10
6.
Serial port connector (10-1 pin COM2)
4-10
7.
BMC header (BMC_FW1)
4-11
8.
Power Supply SMBus connector (5-pin PSUSMB1)
4-11
9.
ATX power connectors (24-pin ATXPWR1, 8-pin ATX12V1)
4-12
10.
System panel connector (20-1 pin PANEL1)
4-13
11.
Auxiliary panel connector (20-2 pin AUX_PANEL1)
4-14
ASUS RS100-E6/PI2
4-3
4.2
1.
Jumpers
Clear RTC RAM (CLRTC1)
This jumper allows you to clear the Real Time Clock (RTC) RAM in CMOS.
You can clear the CMOS memory of date, time, and system setup parameters
by erasing the CMOS RTC RAM data. The onboard button cell battery
powers the RAM data in CMOS, which include system setup information such
as system passwords.
To erase the RTC RAM:
1. Turn OFF the computer and unplug the power cord.
2. Move the jumper cap from pins 1–2 (default) to pins 2–3. Keep the cap
on pins 2–3 for about 5–10 seconds, then move the cap back to pins 1–2.
3. Plug the power cord and turn ON the computer.
4. Hold down the <Del> key during the boot process and enter BIOS setup
to re-enter data.
Except when clearing the RTC RAM, never remove the cap on CLRTC jumper
default position. Removing the cap will cause system boot failure!
If the steps above do not help, remove the onboard battery and move the
jumper again to clear the CMOS RTC RAM data. After the CMOS clearance,
reinstall the battery.
4-4
Chapter 4: Motherboard information
2.
VGA controller setting (3-pin VGA_SW1)
This jumper allows you to enable or disable the onboard VGA controller. Set
to pins 1–2 to activate the VGA feature.
3.
CPU Fan and Chassis Fan control setting
(3-pin CPUFAN_SEL1, CHAFAN_SEL1)
These jumpers allow you to switch for fan pin selection. The CPUFAN_SEL1
jumper is for the CPU fans control and the CHAFAN_SEL1 jumper is for the
front fans and rear fans control. Set to pins 1–2 when using 4-pin fans or pins
2–3 when using 3-pin fans.
•
If you use a 4-pin fan but set the jumper to pin 2–3, the fan you installed
may not work.
•
If you use a 3-pin fan but set the jumper for a 4-pin fan, the fan control will
not work and the fan you installed will always run at full speed.
ASUS RS100-E6/PI2
4-5
4.
5.
4-6
LAN controller setting (3-pin LAN_SW1, LAN_SW2)
These jumpers allow you to enable or disable the onboard Intel® Intel
82574LGigabit LAN controllers. Set to pins 1–2 to activate the Gigabit LAN
feature.
RAID configuration utility selection (3-pin RAID_SEL1)
This jumper allows you to select the RAID configuration utility to use when
you create disk arrays. Place the jumper caps over pins 1–2 if you want to
use the LSI Logic Embedded SATA RAID Setup Utility (default); otherwise,
place the jumper caps to pins 2–3 to use the Intel® Matrix Storage Manager.
Chapter 4: Motherboard information
6.
Force BIOS recovery setting (3-pin RECOVERY1)
This jumper allows you to quickly update or recover the BIOS settings when it
becomes corrupted.
To update the BIOS:
1. Prepare a USB flash disk that contains the original or latest BIOS for the
motherboard (XXXXXX.ROM).
2. Set the jumper to pins 2–3.
3. Insert the USB flash and turn on the system to update the BIOS.
4. Shut down the system.
5. Set the jumper back to pins 1–2.
6. Turn on the system.
ASUS RS100-E6/PI2
4-7
4.3
1.
Internal connectors
Serial ATA connectors (7-pin SATA1–4 [Red]; 7-pin SATA5–6 [Black])
Supported by the Intel® 3420 chipset, these connectors are for the Serial ATA
signal cables for Serial ATA hard disk drives that allows up to 3Gb/s of data
transfer rate.
If you installed Serial ATA hard disk drives, you can create a RAID 0, RAID 1,
RAID 10, or RAID 5 configuration.
The actual data transfer rate depends on the speed of Serial ATA hard disks
installed.
2.
4-8
Hard disk activity LED connector (4-pin HDLED1)
This LED connector is for the storage add-on card cable connected to
the SATA or SAS add-on card. The read or write activities of any device
connected to the SATA or SAS add-on card causes the front panel LED to
light up.
Chapter 4: Motherboard information
3.
4.
USB connector (10-1 pin USB34, USB56; A-Type USB7)
These connectors are for USB 2.0 ports. Connect the USB module cables
to connectors USB34, then install the modules to a slot opening at the
back of the system chassis. These USB connectors comply with USB 2.0
specification that supports up to 480 Mbps connection speed.
CPU, front and rear fan connectors
(4-pin CPU_FAN1, FRNT_FAN1, FRNT_FAN2, FRNT_FAN3, REAR_FAN1)
The fan connectors support cooling fans of 350 mA–740 mA (8.88 W max.)
or a total of 1.75 A–3.7 A (44.4 W max.) at +12V. Connect the fan cables to
the fan connectors on the motherboard, ensuring that the black wire of each
cable matches the ground pin of the connector.
•
DO NOT forget to connect the fan cables to the fan connectors. Insufficient
air flow inside the system may damage the motherboard components.
•
These are not jumpers! DO NOT place jumper caps on the fan connectors!
•
All fans feature the ASUS Fan Speed Control technology.
ASUS RS100-E6/PI2
4-9
5.
6.
4-10
Serial General Purpose Input/Output connector (6-1 pin SGPIO1)
This connector is used for the SGPIO peripherals for the LSI MegaRAID and
Intel Matrix RAID SATA LED.
Serial port connector (10-1 pin COM2)
This connector is for a serial (COM) port. Connect the serial port module
cable to this connector, then install the module to a slot opening at the back
of the system chassis.
Chapter 4: Motherboard information
7.
BMC header (BMC_FW1)
The BMC connector on the motherboard supports an ASUS® Server
Management Board 4 Series (ASMB4).
8.
Power Supply SMBus connector (5-pin PSUSMB1)
This connector allows you to connect SMBus (System Management Bus) to
the power supply unit to read PSU information. Devices communicate with an
SMBus host and/or other SMBus devices using the SMBus interface.
ASUS RS100-E6/PI2
4-11
9.
ATX power connectors (24-pin ATXPWR1, 8-pin ATX12V1)
These connectors are for an ATX power supply plugs. The power supply
plugs are designed to fit these connectors in only one orientation. Find the
proper orientation and push down firmly until the connectors completely fit.
•
DO NOT forget to connect the 24+8-pin power plugs; otherwise, the system
will not boot up.
•
Use of a PSU with a higher power output is recommended when
configuring a system with more power-consuming devices. The system
may become unstable or may not boot up if the power is inadequate.
•
•
4-12
This motherboard supports ATX2.0 PSU or later version.
Ensure that your power supply unit (PSU) can provide at least the minimum
power required by your system.
Chapter 4: Motherboard information
10. System panel connector (20-pin PANEL1)
This connector supports several chassis-mounted functions.
1. System power LED (3-pin PLED)
This 3-pin connector is for the system power LED. Connect the chassis
power LED cable to this connector. The system power LED lights up
when you turn on the system power, and blinks when the system is in
sleep mode.
2. Message LED (2-pin MLED)
This 2-pin connector is for the message LED cable that connects to
the front message LED. The message LED is controlled by Hardware
monitor to indicate an abnormal event occurance.
3. System warning speaker (4-pin SPEAKER)
This 4-pin connector is for the chassis-mounted system warning
speaker. The speaker allows you to hear system beeps and warnings.
4. Hard disk drive activity LED (2-pin HDDLED)
This 2-pin connector is for the HDD Activity LED. Connect the HDD
Activity LED cable to this connector. The IDE LED lights up or flashes
when data is read from or written to the HDD.
5. ATX power button/soft-off button (2-pin PWRSW)
This connector is for the system power button. Pressing the power
button turns the system on or puts the system in sleep or soft-off mode
depending on the BIOS settings. Pressing the power switch for more
than four seconds while the system is ON turns the system OFF.
6. Reset button (2-pin RESET)
This 2-pin connector is for the chassis-mounted reset button for system
reboot without turning off the system power.
ASUS RS100-E6/PI2
4-13
11. Auxiliary panel connector (20-pin AUX_PANEL1)
This connector is for additional front panel features including front panel
SMB, locator LED and switch, chassis intrusion, and LAN LEDs.
1. Front panel SMB (6-1 pin FPSMB)
These leads connect the front panel SMBus cable.
2. LAN activity LED (2-pin LAN1_LED, LAN2_LED)
These leads are for Gigabit LAN activity LEDs on the front panel.
3. Chassis intrusion (4-1 pin CHASSIS)
These leads are for the intrusion detection feature for chassis with
intrusion sensor or microswitch. When you remove any chassis
component, the sensor triggers and sends a high-level signal to these
leads to record a chassis intrusion event. The default setting is short
CASEOPEN and GND pin by jumper cap to disable the function.
4. Locator LED (2-pin LOCATORLED1 and 2-pin LOCATORLED2)
These leads are for the locator LED1 and LED2 on the front panel.
Connect the Locator LED cables to these 2-pin connector. The LEDs will
light up when the Locator button is pressed.
5. Locator Button/Swich (2-pin LOCATORBTN)
These leads are for the locator button on the front panel. This button
queries the state of the system locator.
4-14
Chapter 4: Motherboard information
This chapter tells how to change the
system settings through the BIOS Setup
menus. Detailed descriptions of the BIOS
parameters are also provided.
BIOS setup
Chapter 5
5.1
Managing and updating your BIOS
The following utilities allow you to manage and update the motherboard Basic
Input/Output System (BIOS) setup:
1.
ASUS EZ Flash 2 (Updates the BIOS using a USB flash disk.)
3.
ASUS CrashFree BIOS 3 (To recover the BIOS using a bootable USB flash
disk drive when the BIOS file fails or gets corrupted.)
2.
BUPDATER utility (Updates the BIOS in DOS mode using a bootable USB
flash disk drive.)
Refer to the corresponding sections for details on these utilities.
Save a copy of the original motherboard BIOS file to a bootable USB flash
disk drive in case you need to restore the BIOS in the future. Copy the original
motherboard BIOS using the ASUS Update or AFUDOS utilities.
5.1.1
ASUS EZ Flash 2 utility
The ASUS EZ Flash 2 feature allows you to update the BIOS without having to use
a DOS‑based utility.
Before you start using this utility, download the latest BIOS from the ASUS
website at www.asus.com.
To update the BIOS using EZ Flash 2
1.
2.
Insert the USB flash disk that contains the latest BIOS file to the USB port.
Enter the BIOS setup program. Go to the Tools menu to select EZ Flash 2
and press <Enter> to enable it.
Or, press <Alt> + <F2> during the POST to enable EZ Flash 2.
ASUSTek EZ Flash 2 BIOS ROM Utility V3.34
FLASH TYPE: MXIC 25L1605A
Current ROM
BOARD: P7F-M
VER: 0205
DATE: 07/23/2009
Update ROM
BOARD: Unknown
VER: Unknown
DATE: Unknown
PATH: A:\
A:
Note
[Enter] Select or Load
[Up/Down/Home/End] Move
5-2
[Tab] Switch
[B] Backup
[V] Drive Info
[Esc] Exit
Chapter 5: BIOS setup
3.
Press <Tab> to switch between drives until the correct BIOS file is found.
When found, EZ Flash 2 performs the BIOS update process and automatically
reboots the system when done.
•
This function can support devices such as a USB flash disk with FAT 32/16
format and single partition only.
•
DO NOT shut down or reset the system while updating the BIOS to prevent
system boot failure!
Ensure to load the BIOS default settings to ensure system compatibility and
stability. Select the Load Setup Defaults item under the Exit menu. See section
5.9 Exit Menu for details.
5.1.2
BUPDATER utility
The succeeding BIOS screens are for reference only. The actual BIOS screen
displays may not be the same as shown.
The BUPDATER utility allows you to update the BIOS file in DOS environment
using a bootable USB flash disk drive with the updated BIOS file.
Updating the BIOS file
To update the BIOS file using the BUPDATER utility:
1.
2.
3.
Visit the ASUS website at www.asus.com and download the latest BIOS file
for the motherboard. Save the BIOS file to a bootable USB flash disk drive.
Copy the BUPDATER utility (BUPDATER.exe) from the ASUS support
website at support.asus.com to the bootable USB flash disk drive you created
earlier.
Boot the system in DOS mode, then at the prompt, type:
BUPDATER /i[filename].ROM
where [filename] is the latest or the original BIOS file on the bootable USB
flash disk drive, then press <Enter>.
A:\>BUPDATER /i[file name].ROM
ASUS RS100-E6/PI2
5-3
4.
The utility verifies the file, then starts updating the BIOS file.
ASUSTek BIOS Update for DOS V1.06 (09/08/04)
FLASH TYPE: MXIC 25L1605A
Current ROM
BOARD: P7F-M
VER: 0205
DATE: 07/23/2009
Update ROM
BOARD: P7F-M
VER: 0206
DATE: 08/10/2009
PATH: WARNING! Do not turn off power during flash BIOS
Note
Writing BIOS:
DO NOT shut down or reset the system while updating the BIOS to prevent
system boot failure!
5.
The utility returns to the DOS prompt after the BIOS update process is
completed. Reboot the system from the hard disk drive.
The BIOS update is finished! Please restart your system.
C:\>
5-4
Chapter 5: BIOS setup
5.1.3
ASUS CrashFree BIOS 3 utility
The ASUS CrashFree BIOS 3 is an auto recovery tool that allows you to restore
the BIOS file when it fails or gets corrupted during the updating process. You can
update a corrupted BIOS file using a USB flash drive that contains the updated
BIOS file.
Prepare a USB flash drive containing the updated motherboard BIOS before
using this utility.
Recovering the BIOS from a USB flash drive
To recover the BIOS from a USB flash drive:
1.
2.
Insert the USB flash drive with the original or updated BIOS file to one USB
port on the system.
The utility will automatically recover the BIOS. It resets the system when the
BIOS recovery finished.
DO NOT shut down or reset the system while recovering the BIOS! Doing so
would cause system boot failure!
The recovered BIOS may not be the latest BIOS version for this motherboard.
Visit the ASUS website at www.asus.com to download the latest BIOS file.
ASUS RS100-E6/PI2
5-5
5.2
BIOS setup program
This motherboard supports a programmable firmware chip that you can update
using the provided utility described in section 5.1 Managing and updating your
BIOS.
Use the BIOS Setup program when you are installing a motherboard, reconfiguring
your system, or prompted to “Run Setup.” This section explains how to configure
your system using this utility.
Even if you are not prompted to use the Setup program, you can change the
configuration of your computer in the future. For example, you can enable the
security password feature or change the power management settings. This
requires you to reconfigure your system using the BIOS Setup program so that the
computer can recognize these changes and record them in the CMOS RAM of the
firmware chip.
The firmware chip on the motherboard stores the Setup utility. When you start up
the computer, the system provides you with the opportunity to run this program.
Press <Del> during the Power-On Self-Test (POST) to enter the Setup utility;
otherwise, POST continues with its test routines.
If you wish to enter Setup after POST, restart the system by pressing
<Ctrl+Alt+Delete>, or by pressing the reset button on the system chassis. You can
also restart by turning the system off and then back on. Do this last option only if
the first two failed.
The Setup program is designed to make it as easy to use as possible. Being a
menu-driven program, it lets you scroll through the various sub-menus and make
your selections from the available options using the navigation keys.
5-6
•
The default BIOS settings for this motherboard apply for most conditions
to ensure optimum performance. If the system becomes unstable after
changing any BIOS settings, load the default settings to ensure system
compatibility and stability. Select the Load Default Settings item under the
Exit Menu. See section 5.9 Exit Menu.
•
The BIOS setup screens shown in this section are for reference purposes
only, and may not exactly match what you see on your screen.
•
Visit the ASUS website at www.asus.com to download the latest BIOS file
for this motherboard.
Chapter 5: BIOS setup
5.2.1
BIOS menu screen
Menu items
Main
Configuration fields
Menu bar
Advanced
Server
System Time
System Date
SATA
SATA
SATA
SATA
SATA
SATA
1
2
3
4
5
6
:
:
:
:
:
:
BIOS SETUP UTILITY
Power
Boot
Tools
General help
Exit
[13:44:30]
[Tue, 09/22/2009]
Use [ENTER], [TAB]
or [SHIFT-TAB] to
select a field.
[ST3160812AS]
[Not Detected]
[Not Detected]
[Not Detected]
[Not Detected]
[Not Detected]
Use [+] or [-] to
configure system Date.
Storage Configuration
System Information
←→
↑↓
+Tab
F1
F10
ESC
Select Screen
Select Item
Change Field
Select Field
General Help
Save and Exit
Exit
v02.61 (C)Copyright 1985-2009, American Megatrends, Inc.
Sub-menu items
5.2.2
Navigation keys
Menu bar
The menu bar on top of the screen has the following main items:
Main
For changing the basic system configuration
Server
For changing the advanced server settings
Advanced
For changing the advanced system settings
Power
For changing the advanced power management (APM)
configuration
Tools
For configuring options for special functions
Boot
For changing the system boot configuration
Exit
For selecting the exit options and loading default settings
To select an item on the menu bar, press the right or left arrow key on the keyboard
until the desired item is highlighted.
5.2.3
Navigation keys
At the bottom right corner of a menu screen are the navigation keys for that
particular menu. Use the navigation keys to select items in the menu and change
the settings.
Some of the navigation keys differ from one screen to another.
ASUS RS100-E6/PI2
5-7
5.2.4
Menu items
The highlighted item on the menu bar displays the specific items for that menu; for
example, selecting Main shows the Main menu items.
The other items (Advanced, Power, Boot, and Exit) on the menu bar have their
respective menu items.
5.2.5
Sub-menu items
A solid triangle before each item on any menu screen means that the item has a
sub-menu. To display the sub-menu, select the item and press <Enter>.
5.2.6
Configuration fields
These fields show the values for the menu items. If an item is user-configurable,
you can change the value of the field opposite the item. You cannot select an item
that is not user-configurable.
A configurable field is enclosed in brackets, and is highlighted when selected.
To change the value of a field, select it then press <Enter> to display available
options. Refer to 5.2.7 Pop-up window.
5.2.7
Pop-up window
Select a menu item and press <Enter> to display a pop-up window with the
configuration options for that item.
5.2.8
Scroll bar
A scroll bar appears on the right side of a
menu screen when there are items that do
not fit on the screen. Press the Up/Down
arrow keys or <Page Up> /<Page Down>
keys to display the other items on the
screen.
5.2.9
General help
Pop-up window
Scroll bar
At the top right corner of the menu screen is a brief description of the selected
item.
5-8
Chapter 5: BIOS setup
5.3
Main menu
When you enter the BIOS Setup program, the Main menu screen appears, giving
you an overview of the basic system information.
Refer to section 5.2.1 BIOS menu screen for information on the menu screen
items and how to navigate through them.
Main
Advanced
Server
System Time
System Date
SATA
SATA
SATA
SATA
SATA
SATA
1
2
3
4
5
6
:
:
:
:
:
:
BIOS SETUP UTILITY
Power
Boot
Tools
Exit
[13:44:30]
[Tue, 09/22/2009]
Use [ENTER], [TAB]
or [SHIFT-TAB] to
select a field.
[ST3160812AS]
[Not Detected]
[Not Detected]
[Not Detected]
[Not Detected]
[Not Detected]
Use [+] or [-] to
configure system Date.
←→
↑↓
+Tab
F1
F10
ESC
Storage Configuration
System Information
Select Screen
Select Item
Change Field
Select Field
General Help
Save and Exit
Exit
v02.61 (C)Copyright 1985-2009, American Megatrends, Inc.
5.3.1
System Time [xx:xx:xx]
Allows you to set the system time.
5.3.2
System Date [Day xx/xx/xxxx]
Allows you to set the system date.
5.3.3
SATA1—6
While entering Setup, the BIOS automatically detects the presence of IDE/SATA
devices. There is a separate submenu for each IDE/SATA device. Select a device
item then press <Enter> to display the SATA device information.
BIOS SETUP UTILITY
Main
SATA1
Device
:Hard Disk
Vendor
:xxxxxxxxx
Size
:xx.xGB
LBA Mode :Supported
Block Mode:16Sectors
PIO Mode :4
Async DMA :MultiWord DMA-2
Ultra DMA :Ultra DMA-6
S.M.A.R.T.:Supported
Type [Auto]
LBA/Large Mode [Auto]
Block(Multi-Sector Transfer)M
[Auto]
PIO Mode [Auto]
DMA Mode [Auto]
SMART Monitoring [Auto]
32Bit Data Transfer [Enabled]
Select the type
of device connected
to the system.
←→
↑↓
+F1
F10
ESC
Select Screen
Select Item
Change Option
General Help
Save and Exit
Exit
v02.61 (C)Copyright 1985-2008, American Megatrends, Inc.
ASUS RS100-E6/PI2
5-9
The BIOS automatically detects the values opposite the dimmed items (Device,
Vendor, Size, LBA Mode, Block Mode, PIO Mode, Async DMA, Ultra DMA, and
S.M.A.R.T. monitoring). These values are not user-configurable. These items show
N/A if no IDE device is installed in the system.
Type [Auto]
Allows you to select the type of device connected to the system.
Configuration options: [Not Installed] [Auto] [CDROM] [ARMD]
LBA/Large Mode [Auto]
Enables or disables the LBA mode. Setting to [Auto] enables the LBA mode if the
device supports this mode, and if the device was not previously formatted with LBA
mode disabled. Configuration options: [Disabled] [Auto]
Block (Multi-Sector Transfer) M [Auto]
Enables or disables data multi-sectors transfers. When set to [Auto], the data
transfer from and to the device occurs multiple sectors at a time if the device
supports multi-sector transfer feature. When set to [Disabled], the data transfer
from and to the device occurs one sector at a time.
Configuration options: [Disabled] [Auto]
PIO Mode [Auto]
Allows you to select the data transfer mode.
Configuration options: [Auto] [0] [1] [2] [3] [4]
DMA Mode [Auto]
Sets the DMA mode.
Configuration options: [Auto] [SWDMA0] [SWDMA1] [SWDMA2] [MWDMA0]
[MWDMA1] [MWDMA2] [UDMA0] [UDMA1] [UDMA2] [UDMA3] [UDMA4] [UDMA5]
SMART Monitoring [Auto]
Sets the Smart Monitoring, Analysis, and Reporting Technology.
Configuration options: [Auto] [Disabled] [Enabled]
32Bit Data Transfer [Enabled]
Enables or disables 32-bit data transfer.
Configuration options: [Disabled] [Enabled]
5-10
Chapter 5: BIOS setup
5.3.4
Storage Configuration
The items in this menu allow you to set or change the configurations for the IDE
devices installed in the system. Select an item then press <Enter> if you wish to
configure the item.
BIOS SETUP UTILITY
Main
Storage Configuration
Options
SATA Configuration
Configure SATA as
[Enhanced]
[IDE]
Hard Disk Write Protect
IDE Detect Time Out (Sec)
[Disabled]
[35]
Disabled
Compatible
Enhanced
←→
↑↓
+F1
F10
ESC
Select Screen
Select Item
Change Option
General Help
Save and Exit
Exit
v02.61 (C)Copyright 1985-2009, American Megatrends, Inc.
SATA Configuration [Enhanced]
Configuration options: [Disabled] [Compatible] [Enhanced]
Configure SATA as [IDE]
Sets the configuration for the Serial ATA connectors supported by the
Southbridge chip. Configuration options: [IDE] [RAID] [AHCI]
•
If you want to use the Serial ATA hard disk drives as Parallel ATA physical
storage devices, keep the default setting [IDE].
•
If you want the Serial ATA hard disk drives to use the Advanced Host
Controller Interface (AHCI), set this item to [AHCI]. The AHCI allows
the onboard storage driver to enable advanced Serial ATA features that
increases storage performance on random workloads by allowing the drive
to internally optimize the order of commands.
•
If you want to create RAID sets with LSI MegaRAID utility, or Intel® Matrix
Storage Technology from the Serial ATA hard disk drives, set this item to
[RAID].
Hard Disk Write Protect [Disabled]
Disables or enables device write protection. This will be effective only if the device
is accessed through BIOS.
Configuration option: [Disabled] [Enabled]
IDE Detect Time Out (Sec) [35]
Selects the time out value for detecting ATA/ATAPI devices.
Configuration options: [0] [5] [10] [15] [20] [25] [30] [35]
ASUS RS100-E6/PI2
5-11
5.3.5
AHCI Configuration
This menu is the section for AHCI configuration.
BIOS SETUP UTILITY
Main
AHCI Settings
SATA
SATA
SATA
SATA
SATA
SATA
Port1
Port2
Port3
Port4
Port5
Port6
[Not
[Not
[Not
[Not
[Not
[Not
Some SATA CD/DVD in
AHCI mode need to
wait ready longer.
Detected]
Detected]
Detected]
Detected]
Detected]
Detected]
SATA Port1–6 [XXXX]
Displays the status of auto-detection of SATA devices.
BIOS SETUP UTILITY
Main
SATA Port1
Device
Select the type
of device connected
to the system.
:Not Detected
SATA Port0
SMART Monitoring
[Auto]
[Enabled]
SATA Port0 [Auto]
Allows you to select the type of device connected to the system.
Configuration options: [Auto] [Not Installed]
SMART Monitoring [Enabled]
Allows you to set the Self-Monitoring, Analysis and Reporting Technology.
Configuration options: [Disabled] [Enabled]
5-12
Chapter 5: BIOS setup
5.3.6
System Information
This menu gives you an overview of the general system specifications. The BIOS
automatically detects the items in this menu.
BIOS SETUP UTILITY
Main
BIOS Information
BIOS Version
:0202
BIOS Build Date :09/16/09
Processor
Type
Speed
:Intel(R) Xeon(R) CPU
2.53GHz
:2533MHz
System Memory
Usable Size
X3440 @
: 1016MB
←→
↑↓
Enter
F1
F10
ESC
System Memory Information
Select Screen
Select Item
Go to Sub Screen
General Help
Save and Exit
Exit
v02.61 (C)Copyright 1985-2009, American Megatrends, Inc.
BIOS Information
Displays the auto-detected BIOS information.
Processor
Displays the auto-detected CPU specification.
System Memory
Displays the auto-detected system memory.
System Memory Information
Displays system memory information.
BIOS SETUP UTILITY
Main
System Memory Information
Speed
DIMM_A1
DIMM_A2
DIMM_B1
DIMM_B2
DDR3 1067
1024 MB, 1R, 1067
N/A
N/A
N/A
ASUS RS100-E6/PI2
5-13
5.4
Advanced menu
The Advanced menu items allow you to change the settings for the CPU and other
system devices.
Take caution when changing the settings of the Advanced menu items. Incorrect
field values can cause the system to malfunction.
Main
Advanced
BIOS SETUP UTILITY
Power
Boot
Tools
Server
Exit
Configure CPU.
CPU Configuration
Chipset
Onboard Device Configuration
USB Configuration
PCIPnP
ACPI Configuration
Event Log Configuration
Intel VT-d
SR-IOV Supported
[Disabled]
[Disabled]
←→
↑↓
Enter
F1
F10
ESC
Select Screen
Select Item
Go to Sub Screen
General Help
Save and Exit
Exit
v02.61 (C)Copyright 1985-2009, American Megatrends, Inc.
5.4.1
CPU Configuration
The items in this menu show the CPU-related information that the BIOS
automatically detects. Some items may not appear if your CPU does not support
the related functions.
Advanced
BIOS SETUP UTILITY
Configure advanced CPU settings
Module Version:01.04
Manufacturer:Intel
Brand String:Intel(R) Xeon(R) CPU
Frequency
:2.53GHz
BCLK Speed :133MHz
Cache L1
:128 KB
Cache L2
:1024 KB
Cache L3
:8192 KB
Ratio Status:Unlocked (Min:09, Max:19)
Ratio Actual Value :19
CPUID
:106E5
Ratio CMOS Setting:
C1E Support
Hardware Prefetcher
Adjacent Cache Line Prefetch
Max CPUID Value Limit
Intel(R) Virtualization Tech
[Auto]
[Enabled]
[Enabled]
[Enabled]
[Disabled]
[Enabled]
X3440
Sets the ratio between
CPU Core Clock and the
FSB Frequency.
Note:If an invalid
ratio is set in CMOS
then actual and
setpoint values may
differ.
←→
↑↓
+F1
F10
ESC
Select Screen
Select Item
Change Option
General Help
Save and Exit
Exit
v02.61 (C)Copyright 1985-2009, American Megatrends, Inc.
5-14
Chapter 5: BIOS setup
Scroll down for more items.
Advanced
BIOS SETUP UTILITY
CPU TM Function
Execute-Disable Bit Capability
Intel(R) HT Technology
Active Processor Cores
A20M
Intel(R) SpeedStep(TM) Tech
Intel(R) TurboMode Tech
Intel(R) C-STATE Tech
C3 State
C6 State
C State package limit setting
C1 Auto Demotion
C3 Auto Demotion
[Enabled]
[Enabled]
[Enabled]
[All]
[Disabled]
[Enabled]
[Enabled]
[Enabled]
[ACPI C2]
[Enabled]
[Auto]
[Enabled]
[Enabled]
Sets the ratio between
CPU Core Clock and the
FSB Frequency.
Note:If an invalid
ratio is set in CMOS
then actual and
setpoint values may
differ.
←→
↑↓
+F1
F10
ESC
Select Screen
Select Item
Change Option
General Help
Save and Exit
Exit
v02.61 (C)Copyright 1985-2008, American Megatrends, Inc.
Ratio CMOS Setting [Auto]
Allows you to adjust the ratio between CPU Core Clock and BCLK Frequency. Use
the <+> and <-> keys to adjust the value.
Configuration options: [Auto] [09.0] [10.0] [11.0] [12.0] [13.0] [14.0] [15.0] [16.0]
[17.0] [18.0] [19.0] [20.0]
C1E Support [Enabled]
Allows you to enable or disable Enhanced Halt State support.
Configuration options: [Disabled] [Enabled]
Hardware Prefetcher [Enabled]
Allows you to enable or disable the Hardware Prefetcher function.
Configuration options: [Disabled] [Enabled]
Adjacent Cache Line Prefetch [Enabled]
Allows you to enable or disable the Adjacent Cache Line Prefetch function.
Configuration options: [Disabled] [Enabled]
Max CPUID Value Limit [Disabled]
Setting this item to [Enabled] allows legacy operating systems to boot even without
support for CPUs with extended CPUID functions.
Configuration options: [Disabled] [Enabled]
Intel(R) Virtualization Tech [Enabled]
The Intel® Virtualization Technology allows a hardware platform to run multiple
operating systems separately and simultaneously, enabling one system to virtually
function as several systems. Configuration options: [Disabled] [Enabled]
ASUS RS100-E6/PI2
5-15
CPU TM Function [Enabled]
This function enables the overheated CPU to throttle the clock speed to cool down.
Configuration options: [Disabled] [Enabled]
Execute-Disable Bit Capability [Enabled]
Allows you to enable or disable the No-Execution Page Protection Technology.
Setting this item to [Disabled] forces the XD feature flag to always return to zero
(0). Configuration options: [Disabled] [Enabled]
Intel(R) HT Technology [Disabled]
Allows you to enable or disable the Intel Hyper-Threading Technology function.
When disabled, only one thread per activated core is enabled.
Configuration options: [Enabled] [Disabled]
Active Processor Cores [All]
Allows you to choose the number of CPU cores to activate in each processor
package.Configuration options: [All] [1] [2]
A20M [Disabled]
Legacy OSes and APs may need A20M enabled.
Configuration options: [Disabled] [Enabled]
Intel(R) SpeedStep (TM) Tech [Enabled]
When set to [Disabled], the CPU runs at its default speed. When set to [Enabled],
the CPU speed is controlled by the operating system.
Configuration options: [Disabled] [Enabled]
Intel(R) TurboMode Tech [Enabled]
Turbo mode allows processor cores to run faster than marked frequency in specific
condition.Configuration options: [Disabled] [Enabled]
Intel(R) C-STATE Tech [Enabled]
The Intel® C-State Technology allows the CPU to save more power under idle
mode. Enable this item only when you install a C-State Technology-supported
CPU. Configuration options: [Disabled] [Enabled]
The following items appear only when you set the Intel(R) C-STATE Tech
item to [Enabled].
C3 State [ACPI C2]
Allows you to select Nehalem C state action.
Configuratiton options: [Disabled] [ACPI C2] [ACPI C3]
5-16
Chapter 5: BIOS setup
C6 State [Enabled]
Allows you to select Nehalem C state action.
Configuratiton options: [Disabled] [Enabled]
C State package limit setting [Auto]
We recommend that you set this item to [Auto] for BIOS to automatically detect the
C-State mode supported by your CPU.
Configuration options: [Auto] [C1] [C3] [C6]
C1 Auto Demotion [Enabled]
When this item is enabled, the CPU will conditionally demote C3/C6 requests to C1
based on the uncore auto-demote information.
Configuration options: [Disabled] [Enabled]
C3 Auto Demotion [Enabled]
When this item is enabled, the CPU will conditionally demote C6 requests to C3
based on the uncore auto-demote information.
Configuration options: [Disabled] [Enabled]
ASUS RS100-E6/PI2
5-17
5.4.2
Chipset
The Chipset configuration menu allows you to change advanced chipset settings.
Select an item then press <Enter> to display the sub-menu.
Advanced
BIOS SETUP UTILITY
Advanced Chipset Settings
Configure North Bridge
features.
WARNING: Setting wrong values in below sections
may cause system to malfunction.
Uncore Configuration
←→
↑↓
Enter
F1
F10
ESC
Select Screen
Select Item
Go to Sub Screen
General Help
Save and Exit
Exit
v02.61 (C)Copyright 1985-2009, American Megatrends, Inc.
Uncore Configuration
Advanced
BIOS SETUP UTILITY
CPU Bridge
Uncore
Configuration
Chipset Configuration
IMC :
CPU
REVISION
Lynnfield
:B0
Current CSI Frequency :6.400GT
Memory
CurrentRemap
Memory
Feature
Frequency :1066
[Enabled]
Mhz
PCI MMIO Allocation: 4GB To 3072MB
DRAM
CSI Links
Frequency
Speed
[Auto]
[Full-Speed]
Configure
CSI Frequency
DRAM Timing by SPD
[Enabled]
[Auto]
DRAM Margin Ranks
[Disabled]
MRC
Serial
Debug Message Level [Disabled]
Memory
Frequency
[Auto]
Memory Mode
[Independent]
Demand Scrubbing
[Disabled]
Memory
Function
[Enabled]
Patrol ECC
Scrubbing
[Disabled]
Double
Rate-Refresh
[Auto]
Throttling
Closed Loop
[Disabled]
Page
Policy
[Closed]
Throttling
- Open Loop
[Disabled]
Adaptive Page
[Disabled]
Data Scramble
[Enabled]
Memory Thermal Throttling
[Disabled]
ENABLE:
To
transition
Allow the CSI
remapping
links to of
full-speed
overlapped
or leave them
PCI memory
in
above
slow-mode.
the total
physical memory.
DISABLE: Do not allow
remapping of memory.
←→
↑↓
+F1
F10
ESC
Select Screen
Select Item
Change Option
General Help
Save and Exit
Exit
v02.61 (C)Copyright 1985-2009,
1985-2008, American Megatrends, Inc.
Memory Remap Feature [Enabled]
Setting this item to [Enabled] allows you to remapp the overlapped PCI memory
above the total physical memory. Configuration options: [Disabled] [Enabled]
DRAM Frequency [Auto]
You may allow the system to detect DDR3 memory frequency via SPD or designate
a specific frequency.
Configuration options: [Auto] [800 MHz] [1066 MHz] [1333 MHz]
Refer to the memory AVL on ASUS website at www.asus.com.
5-18
Chapter 5: BIOS setup
Configure DRAM Timing by SPD [Enabled]
Configuration options: [Enabled] [Disabled]
The ofllowing 10 items appear when you set Configure DRAM Timing by SPD to
[Disabled].
DRAM tCL [7]
Configuration options: [3]—[15]
DRAM tRAS [20]
Configuration options: [9]—[63]
DRAM tRP [7]
Configuration options: [3]—[15]
DRAM tRCD [7]
Configuration options: [3]—[15]
DRAM tWR [8]
Configuration options: [3]—[31]
DRAM tRFC [59]
Configuration options: [15]—[255]
DRAM tWTR [4]
Configuration options: [4]—[31]
DRAM tRRD [4]
Configuration options: [4]—[15]
DRAM tRTP [4]
Configuration options: [4]—[15]
DRAM tFAW [20]
Configuration options: [15]—[63]
DRAM Margin Ranks [Disabled]
Configuration options: [Enabled] [Disabled]
MRC Serial Debug Message Level [Disabled]
Configuration options: [Disabled] [Minimum] [Maximum] [Test]
Memory ECC Function [Enabled]
Allows you to enable or disable Memory ECC fucntion.
Configuration options: [Disabled] [Enabled]
ASUS RS100-E6/PI2
5-19
Double Rate Refresh [Auto]
Allows you to enable or disable Double Rate Refresh.
Configuration options: [Auto] [Disabled]
Page Poilcy [Closed]
Configuration options: [Closed] [Open]
Adaptive Page [Disabled]
Configuration options: [Disabled] [Enabled]
Data Scramble [Disabled]
Configuration options: [Disabled] [Enabled]
Memory Thermal Throttling [Disabled]
Setting this item to [CLTT] to Closed Loop Thermal Throttling and [OLTT] to Open
Loop Thermal Throttling. Configuration options: [CLTT] [OLTT] [Disabled] [Auto]
5.4.3
Onboard Devices Configuration
The Onboard Devices Configuration menu items allow you to change the advanced
settings for onboard devices.
Take caution when changing the settings of the Onboard Devices Configuration
menu items. Incorrect field values can cause the system to malfunction.
Advanced
BIOS SETUP UTILITY
Onboard Devices Configuration
HDA Controller
OnBoard LAN1 Boot ROM
OnBoard LAN2 Boot ROM
Serial Port1 Address
Serial Port2 Address
Interrupt 19 Capture
Options
[Enabled]
[PXE]
[PXE]
[3F8/IRQ4]
[2F8/IRQ3]
[Enabled]
Enabled
Disabled
←→
↑↓
+F1
F10
ESC
Select Screen
Select Item
Change Option
General Help
Save and Exit
Exit
v02.61 (C)Copyright 1985-2009, American Megatrends, Inc.
HDA Controller [Enabled]
Allows you to enable or disable the High Definition Audio controller.
Configuration options: [Enabled] [Disabled]
5-20
Chapter 5: BIOS setup
Onboard LAN1/2 Boot ROM [PXE]
Allows you to configure the onboard LAN1/2 boot mode.
Configuration: [Disabled] [PXE] [iSCSI]
Serial Port1 Address [3F8/IRQ4]
Allows you to select the Serial Port1 base address.
Configuration options: [Disabled] [3F8/IRQ4] [3E8/IRQ4] [2E8/IRQ3]
Serial Port2 Address [2F8/IRQ3]
Allows you to select the Serial Port2 base address.
Configuration options: [Disabled] [2F8/IRQ3] [3E8/IRQ4] [2E8/IRQ3]
Interrupt 19 Capture [Enabled]
When set to [Enabled], this function allows the option ROMs to trap Interrupt 19.
Configuration options: [Disabled] [Enabled]
5.4.4
USB Configuration
Advanced
BIOS SETUP UTILITY
USB Configuration
Options
Module Version - 2.24.3-13.4
Disabled
Enabled
USB Devices Enabled:
2 Hubs
USB Functions
Legacy USB Support BIOS EHCI Hand-off
[Enabled]
[Auto]
[Enabled]
←→
↑↓
+F1
F10
ESC
Select Screen
Select Item
Change Option
General Help
Save and Exit
Exit
v02.61 (C)Copyright 1985-2008, American Megatrends, Inc.
USB Functions [Enabled]
Allows you to enabled or disable the USB function.
Configuration options: [Disabled] [Enabled]
Legacy USB Support [Enabled]
Allows you to enable or disable support for legacy USB devices. Setting to [Auto]
allows the system to detect the presence of USB devices at startup. If detected, the
USB controller legacy mode is enabled. If no USB device is detected, the legacy
USB support is disabled. Configuration options: [Disabled] [Enabled] [Auto]
ASUS RS100-E6/PI2
5-21
BIOS EHCI Hand-Off [Enabled]
Enables or disables the BIOS EHCI hand-off support.
Configuration options: [Disabled] [Enabled]
5.4.5
PCIPnP
The PCIPnP menu items allow you to change the advanced settings for PCI/PnP
devices.
Take caution when changing the settings of the PCI/PnP Configuration menu
items. Incorrect field values can cause the system to malfunction.
Advanced
BIOS SETUP UTILITY
Advanced PCI/PnP Settings
WARNING: Setting wrong values in below sections
may cause system to malfunction.
Plug And Play O/S
[No]
PCI Option ROM Scan Order [Bus 0 First]
Onboard Option ROM Priority [Normal]
NO: lets the BIOS
configure all the
devices in the system.
YES: lets the
operating system
configure Plug and
Play (PnP) devices not
required for boot if
your system has a Plug
and Play operating
system.
←→
↑↓
+F1
F10
ESC
Select Screen
Select Item
Change Option
General Help
Save and Exit
Exit
v02.61 (C)Copyright 1985-2009, American Megatrends, Inc.
Plug And Play O/S [No]
When set to [No], BIOS configures all the devices in the system. When set to
[Yes] and if you install a Plug and Play operating system, the operating system
configures the Plug and Play devices not required for boot.
Configuration options: [No] [Yes]
PCI Option ROM Scan Order [Bus 0 First]
Allows you to select the PCI option ROM scanning order. The scanning of the
option ROM will start from the lowest bus, device, fucntion number if you set this
item to [Bus 0 First]; the scanning starts from the highest bus, device, function
number if you set this item to [Bus N First].
Configuration options: [Bus 0 First] [Bus N First]
Onboard Option ROM Priority [Normal]
Allows you to select the onboard option ROM priority.
Configuration options: [Normal] [High]
5-22
Chapter 5: BIOS setup
5.4.6
ACPI Configuration
BIOS SETUP UTILITY
Advanced
ACPI Settings
Advanced ACPI
Configuration
settings.
Advanced ACPI Configuration
Chipset ACPI Configuration
General WHEA Configuration
Use this section to
configure additional
ACPI options.
←→
↑↓
+F1
F10
ESC
Select Screen
Select Item
Change Option
General Help
Save and Exit
Exit
v02.61 (C)Copyright 1985-2009, American Megatrends, Inc.
Advanced ACPI Configuration
Advanced
BIOS SETUP UTILITY
Advanced ACPI Configuration
ACPI APIC support
BIOS-->AML ACPI table
Headless mode
[Enabled]
[Enabled]
[Disabled]
Add additional tables
as per ACPI 2.0
specifications.
ACPI APIC Support [Enabled]
Allows you to enable or disable the Advanced Configuration and Power Interface
(ACPI) support in the Advanced Programmable Interrupt Controller (APIC). When
set to [Enabled], the ACPI APIC table pointer is included in the RSDT pointer list.
Configuration options: [Disabled] [Enabled]
BIOS-->AML ACPI table [Enabled]
Allows you to include the BIOS-->AML exchange table pointer to (X)RSDT pointer
list.Configuration options: [Disabled] [Enabled]
Headless mode [Disabled]
Allows you to enable or disable the Headless operation mode through ACPI.
Configuration options: [Disabled] [Enabled]
ASUS RS100-E6/PI2
5-23
Chipset ACPI Configuration
Advanced
BIOS SETUP UTILITY
South Bridge ACPI Configuration
Energy Lake Feature
APIC ACPI SCI IRQ
High Performance Event Timer
HPET Memory Address
Options
[Disabled]
[Disabled]
[Disabled]
[FED00000h]
Enabled
Disabled
Energy Lake Feature [Disabled]
Allows you to enable or disable the Energy Lake feature.
Configuration options: [Enabled] [Disabled]
We do not recommend you enable this feature.
APIC ACPI SCI IRQ [Disabled]
Allows you to enable or disable the APIC ACPI SCI IRQ feature.
Configuration options: [Disabled] [Enabled]
High Performance Event Timer [Disabled]
Allows you to enable or disable the High Performance Event Timer feature.
Configuration options: [Disabled] [Enabled]
HPET Memory Address [FED00000h]
Configuration options: [FED00000h] [FED01000h] [FED02000h] [FED03000h]
General WHEA Configuration
Advanced
BIOS SETUP UTILITY
General WHEA Configuration
WHEA Support
Options
[Enabled]
Enabled
Disabled
WHEA Support [Enabled]
Allows you to enable or disable the Windows Hardware Error Architecture.
Configuration options: [Disabled] [Enabled]
5-24
Chapter 5: BIOS setup
5.4.7
Event Log Configuration
Advanced
BIOS SETUP UTILITY
Event Logging details
View all unread events
on the Event log.
View Event Log
Mark all event as read
Clear Event Log
←→
↑↓
Enter
F1
F10
ESC
Select Screen
Select Item
Go to Sub Screen
General Help
Save and Exit
Exit
v02.61 (C)Copyright 1985-2009, American Megatrends, Inc.
View Event Log
Press <Enter> to read all the unread event log.
Mark all events as read
Press <Enter> to mark all the events as read.
Clear Event Log
Press <Enter> to clear all events on the event log.
5.4.8
Intel VT-d Configuration [Disabled]
Allows you to enable or disable the Intel Virtualization Technology for Directed I/O.
Configuration options: [Disabled] [Enabled]
5.4.9
SR-IOV Supprted [Disabled]
Configuration options: [Disabled] [Enabled]
ASUS RS100-E6/PI2
5-25
5.5
Server menu
The Server menu items allow you to customize the server features.
Main
Advanced
BIOS SETUP UTILITY
Power
Boot
Tools
Server
Exit
IPMI configuration
including server
monitoring and
event log.
Remote Access Configuration
←→
↑↓
Enter
F1
F10
ESC
Select Screen
Select Item
Go to Sub Screen
General Help
Save and Exit
Exit
v02.61 (C)Copyright 1985-2009, American Megatrends, Inc.
Remote Access Configuration
The items in this menu allows you to configure the Remote Access features. Select
an item then press <Enter> to display the configuration options.
BIOS SETUP UTILITY
Server
Configure Remote Access type and parameters
Remote Access
[Enabled]
Serial port number
Base Address, IRQ
Serial Port Mode
Flow Control
Redirection After BIOS POST
Terminal Type
[COM2]
[2F8h, 3]
[57600 8,n,1]
[Hardware]
[Disabled]
[VT-UTF8]
Select Remote Access
type.
Remote Access [Enabled]
Enables or disables the remote access feature.
Configuration options: [Disabled] [Enabled]
The following items appear only when Remote Access is set to [Enabled].
Serial port number [COM2]
Selects the serial port for console redirection.
Configuration options: [COM1] [COM2]
Base Address. IRQ [2F8h, 3]
This item is not user-configurable and changes with the configuration of Serial
port number.
5-26
Chapter 5: BIOS setup
Serial port Mode [57600 8,n,1]
Sets the Serial port mode.
Configuration options: [115200 8,n,1] [57600 8,n,1] [38400 8,n,1] [19200 8,n,1]
[09600 8,n,1]
Flow Control [Hardware]
Allows you to select the flow control for console redirection.
Configuration options: [None] [Hardware] [Software]
Redirection After BIOS POST [Disabled]
Sets the redirection mode after the BIOS Power-On Self-Test (POST). Some
operating system may not work when set to [Always].
Configuration options: [Disabled] [Boot Loader] [Always]
Terminal Type [VT-UTF8]
Allows you to select the target terminal type.
Configuration options: [ANSI] [VT100] [VT-UTF8]
ASUS RS100-E6/PI2
5-27
5.6
Main
Power menu
Advanced
Server
BIOS SETUP UTILITY
Power
Boot
Tools
Exit
Include ACPI APIC
table pointer to
RSDT pointer list.
APM Configuration
Hardware Monitor
←→
↑↓
+F1
F10
ESC
Select Screen
Select Item
Change Option
General Help
Save and Exit
Exit
v02.61 (C)Copyright 1985-2009, American Megatrends, Inc.
5.6.1
APM Configuration
BIOS SETUP UTILITY
Power
APM Configuration
Restore on AC Power Loss
Power On By RTC Alarm
Power On By External Modems
Power On By PCI Devices
Power On By PCIE Devices
[Last State]
[Disabled]
[Disabled]
[Disabled]
[Disabled]
<Enter> to select
whether or not to
restart the system
after AC power loss.
←→
↑↓
+F1
F10
ESC
Select Screen
Select Item
Change Option
General Help
Save and Exit
Exit
v02.61 (C)Copyright 1985-2009, American Megatrends, Inc.
Restore on AC Power Loss [Last State]
When set to [Power Off], the system goes into off state after an AC power loss.
When set to [Power On], the system will reboot after an AC power loss. When set
to [Last State], the system goes into either off or on state, whatever the system
state was before the AC power loss.
Configuration options: [Power Off] [Power On] [Last State]
5-28
Chapter 5: BIOS setup
Power On By RTC Alarm [Disabled]
Allows you to enable or disable RTC to generate a wake-up event.
Configuration options: [Disabled] [Enabled]
The following items appear only when the Resume On RTC Alarm item is set
to [Enabled].
RTC Alarm Date [15]
To set the alarm date, highlight this item and press the <+> or <-> key to make the
selection.
System Time [12:30:30]
Use the <ENTER>, <TAB> or <SHIFT-TAB> key to select a field. Use the <+> or
<-> key to configure alarm time.
Power On By External Modems [Disabled]
[Disabled]Disables to power up the computer when the external modem
receives a call while the computer is in Soft-off mode.
[Enabled]The computer could be powered up when the external modem
receives a call while the computer is in Soft-off mode.
The computer cannot receive or transmit data until the computer and
applications are fully running. Thus, connection cannot be made on the first
try. Turning an external modem off and then back on while the computer is off
causes an initialization string that turns the system power on.
Power On By PCI Devices [Disabled]
[Disabled]
[Enabled]
Disables the PME to wake up from S5 by PCI devices.
Allows you to turn on the system through a PCI LAN or modem
card. This feature requires an ATX power supply that provides at
least 1A on the +5VSB lead.
Power On By PCIE Devices [Disabled]
Allows you to enable or disable the PCIE devices to generate a wake event.
[Disabled]Disables the PCIE devices to generate a wake event.
[Enabled]Enables the PCIE devices to generate a wake event.
ASUS RS100-E6/PI2
5-29
5.6.2
Hardware Monitor
BIOS SETUP UTILITY
Power
Hardware Monitor
CPU Temperature(PECI)
MB Temperature
TR1 Temperature
CPU Fan1 Speed
FRNT FAN1 Speed
FRNT FAN2 Speed
FRNT FAN3 Speed
REAR FAN1 Speed
FAN Speed Control
VCORE1 3V
Voltage 5V
Voltage
12V
Voltage
VBatt
Voltage
3VSB
Voltage
1.5V
Voltage
[ 35ºC/ 94ºF]
[ 30ºC/ 86ºF]
[ N/A
]
[ 5357RPM]
[ N/A
]
[ N/A
]
[ N/A
]
[ N/A
]
[Generic Mode]
[ 1.052 V]
[ 3.246 V]
[ 5.196 V]
[12.000 V]
[ 3.126 V]
[ 3.198 V]
[ 1.504 V]
CPU1 Temperature
←→
↑↓
+F1
F10
ESC
Select Screen
Select Item
Change Option
General Help
Save and Exit
Exit
v02.61 (C)Copyright 1985-2009, American Megatrends, Inc.
CPU1/MB1/TR1 Temperature [xxxºC/xxxºF]
The onboard hardware monitor automatically detects and displays the motherboard
component and CPU temperatures. Select [Ignored] if you do not wish to display
the detected temperatures.
CPU Fan1; Front Fan1–3 Speed [xxxxRPM] or [Ignored] / [N/A]
Rear Fan1 Speed [xxxxRPM] or [Ignored] / [N/A]
The onboard hardware monitor automatically detects and displays the speed of
CPU fans, front fans, and rear fans in rotations per minute (RPM). If the fan is not
connected to the motherboard, the field shows [N/A].
Fan Speed Control [Generic Mode]
Allows you to configure the ASUS Smart Fan feature that smartly adjusts the fan
speeds for more efficient system operation.
Configuration options: [Full Speed Mode] [High Density Mode] [Generic Mode]
[Whisper Mode]
The default setting for the RS100-E6/PI2 server is [Whisper Mode].
VCORE1, 3.3V Voltage, 5V Voltage, 12V Voltage, VBatt Voltage,
3VSB Voltage, 1.5V Voltage
The onboard hardware monitor automatically detects the voltage output through
the onboard voltage regulators. Select [Ignored] if you do not want to detect this
item.
5-30
Chapter 5: BIOS setup
5.7
Boot menu
The Boot menu items allow you to change the system boot options. Select an item
then press <Enter> to display the sub-menu.
Main
Advanced
BIOS SETUP UTILITY
Power
Boot
Tools
Server
Exit
Specifies the Boot
Device Priority
sequence.
Boot Settings
Boot Device Priority
Boot Settings Configuration
Security
A virtual floppy disk
drive (Floppy Drive B:
) may appear when you
set the CD-ROM drive
as the first boot
device.
←→
↑↓
Enter
F1
F10
ESC
Select Screen
Select Item
Go to Sub Screen
General Help
Save and Exit
Exit
v02.61 (C)Copyright 1985-2009, American Megatrends, Inc.
5.7.1
Boot Device Priority
BIOS SETUP UTILITY
Boot
Boot Device Priority
1st
2nd
3rd
4th
5th
Boot
Boot
Boot
Boot
Boot
Device
Device
Device
Device
Device
[Removable Dev.]
[ATAPI CD-ROM]
[Hard Drive]
[Network:IBA GE Slo]
[Network:IBA GE Slo]
Specifies the Boot
Device Priority
sequence.
A device enclosed
in parenthesis has
been disabled in the
corresponding type
menu.
←→
↑↓
+F1
F10
ESC
Select Screen
Select Item
Change Option
General Help
Save and Exit
Exit
v02.61 (C)Copyright 1985-2009, American Megatrends, Inc.
1st ~ xxth Boot Device [XXXXXXX]
These items specify the boot device priority sequence from the available devices.
The number of device items that appears on the screen depends on the number of
devices installed in the system.
Configuration options: [xxxxx Drive] [Disabled]
5.7.2
Hard Disk Drives; CDROM Drives
These two items appear only when you install more than two hard disk drives or
optical drives to you system. These items allows you to specify the boot priority
sequence of the hard disk drives or the optical drives.
ASUS RS100-E6/PI2
5-31
5.7.3
Boot Settings Configuration
BIOS SETUP UTILITY
Boot
Boot Settings Configuration
Quick Boot Full Screen Logo
AddOn ROM Display Mode
Bootup Num-Lock
Wait For ‘F1‘ If Error
Hit ‘DEL‘ Message Display
[Enabled]
[Disabled]
[Force BIOS]
[On]
[Enabled]
[Enabled]
Allows BIOS to skip
certain tests while
booting. This will
decrease the time
needed to boot the
system.
←→
↑↓
+F1
F10
ESC
Select Screen
Select Item
Change Option
General Help
Save and Exit
Exit
v02.61 (C)Copyright 1985-2009, American Megatrends, Inc.
Quick Boot [Enabled]
Enabling this item allows the BIOS to skip some power on self tests (POST) while
booting to decrease the time needed to boot the system. When set to [Disabled],
BIOS performs all the POST items.
Configuration options: [Disabled] [Enabled]
Full Screen Logo [Enabled]
Allows you to enable or disable the full screen logo display feature.
Configuration options: [Disabled] [Enabled]
Set this item to [Enabled] to use the ASUS MyLogo2™ feature.
AddOn ROM Display Mode [Force BIOS]
Allows you to set the display mode for Options ROM.
Configuration options: [Force BIOS] [Keep Current]
Bootup Num-Lock [On]
Allows you to select the power-on state for the NumLock.
Configuration options: [Off] [On]
Wait For ‘F1‘ If Error [Enabled]
When set to [Enabled], the system waits for the <F1> key to be pressed when error
occurs. Configuration options: [Disabled] [Enabled]
Hit ‘DEL‘ Message Display [Enabled]
When set to [Enabled], the system displays the message “Press DEL to run Setup”
during POST. Configuration options: [Disabled] [Enabled]
5-32
Chapter 5: BIOS setup
5.7.4
Security
The Security menu items allow you to change the system security settings. Select
an item then press <Enter> to display the configuration options.
Main
Advanced
Server
BIOS SETUP UTILITY
Power
Boot
Tools
Security Settings
Supervisor Password : Not Installed
User Password
: Not Installed
Exit
<Enter> to change
password.
<Enter> again to
disable password.
Change Supervisor Password
Change User Password
←→
↑↓
Enter
F1
F10
ESC
Select Screen
Select Item
Change
General Help
Save and Exit
Exit
v02.61 (C)Copyright 1985-2009, American Megatrends, Inc.
Change Supervisor Password
Select this item to set or change the supervisor password. The Supervisor
Password item on top of the screen shows the default Not Installed. After you set
a password, this item shows Installed.
To set a Supervisor Password:
1.
2.
3.
Select the Change Supervisor Password item and press <Enter>.
From the password box, type a password composed of at least six letters
and/or numbers, then press <Enter>.
Confirm the password when prompted.
The message “Password Installed” appears after you successfully set your
password.
To change the supervisor password, follow the same steps as in setting a user
password.
To clear the supervisor password, select the Change Supervisor Password then
press <Enter>. The message “Password Uninstalled” appears.
If you forget your BIOS password, you can clear it by erasing the CMOS Real
Time Clock (RTC) RAM. See section 4.2 Jumpers for information on how to
erase the RTC RAM.
ASUS RS100-E6/PI2
5-33
After you have set a supervisor password, the other items appear to allow you to
change other security settings.
Main
Advanced
Server
BIOS SETUP UTILITY
Power
Boot
Tools
Supervisor Password : Installed
User Password
: Not Installed
Change Supervisor Password
User Access Level
Change User Password
Password Check
[Full Access]
Exit
<Enter> to change
password.
<Enter> again to
disable password.
[Setup]
User Access Level [Full Access]
This item allows you to select the access restriction to the Setup items.
Configuration options: [No Access] [View Only] [Limited] [Full Access]
No Access prevents user access to the Setup utility.
View Only allows access but does not allow change to any field.
Limited allows changes only to selected fields, such as Date and Time.
Full Access allows viewing and changing all the fields in the Setup utility.
Change User Password
Select this item to set or change the user password. The User Password item on
top of the screen shows the default Not Installed. After you set a password, this
item shows Installed.
To set a User Password:
1.
2.
3.
Select the Change User Password item and press <Enter>.
On the password box that appears, type a password composed of at least six
letters and/or numbers, then press <Enter>.
Confirm the password when prompted.
The message “Password Installed” appears after you set your password
successfully.
To change the user password, follow the same steps as in setting a user password.
Password Check [Setup]
When set to [Setup], BIOS checks for user password when accessing the Setup
utility. When set to [Always], BIOS checks for user password both when accessing
Setup and booting the system. Configuration options: [Setup] [Always]
5-34
Chapter 5: BIOS setup
5.8
Tools menu
The Tools menu items allow you to configure options for special functions. Select
an item then press <Enter> to display the submenu.
Main
Advanced
Server
BIOS SETUP UTILITY
Power
Boot
Tools
ASUS EZ Flash 2
Exit
Press ENTER to run
the utility to select
and update BIOS.
This uitlity supports
1. FAT 12/16/32 (r/w)
2. NTFS (read only)
3. CD-DISC (read only)
←→
↑↓
Enter
F1
F10
ESC
Select Screen
Select Item
Go to Sub Screen
General Help
Save and Exit
Exit
v02.61 (C)Copyright 1985-2008, American Megatrends, Inc.
5.8.1
ASUS EZ Flash 2
Allows you to run ASUS EZ Flash 2. When you press <Enter>, a confirmation
message appears. Use the left/right arrow key to select between [Yes] or [No],
then press <Enter> to confirm your choice. Check section 5.1.1 ASUS EZ Flash 2
utility for details.
ASUS RS100-E6/PI2
5-35
5.9
Exit menu
The Exit menu items allow you to load the optimal or failsafe default values for the
BIOS items, and save or discard your changes to the BIOS items.
Main
Advanced
Server
Exit Options
Exit & Save Changes
Exit & Discard Changes
Discard Changes
Load Setup Defaults
BIOS SETUP UTILITY
Power
Boot
Tools
Exit
Exit system setup
after saving the
changes.
F10 key can be used
for this operation.
←→
↑↓
Enter
F1
F10
ESC
Select Screen
Select Item
Go to Sub Screen
General Help
Save and Exit
Exit
v02.61 (C)Copyright 1985-2009, American Megatrends, Inc.
Pressing <Esc> does not immediately exit this menu. Select one of the options
from this menu or <F10> from the legend bar to exit.
Exit & Save Changes
Once you are finished making your selections, choose this option from the Exit
menu to ensure the values you selected are saved to the CMOS RAM. An onboard
backup battery sustains the CMOS RAM so it stays on even when the PC is turned
off. When you select this option, a confirmation window appears. Select YES to
save changes and exit.
If you attempt to exit the Setup program without saving your changes, the
program prompts you with a message asking if you want to save your changes
before exiting. Press <Enter> to save the changes while exiting.
Exit & Discard Changes
Select this option only if you do not want to save the changes that you made to the
Setup program. If you made changes to fields other than System Date, System
Time, and Password, the BIOS asks for a confirmation before exiting.
Discard Changes
This option allows you to discard the selections you made and restore the
previously saved values. After selecting this option, a confirmation appears. Select
YES to discard any changes and load the previously saved values.
Load Setup Defaults
This option allows you to load the default values for each of the parameters on the
Setup menus. When you select this option or if you press <F5>, a confirmation
window appears. Select YES to load default values. Select Exit & Save Changes
or make other changes before saving the values to the non-volatile RAM.
5-36
Chapter 5: BIOS setup
This chapter provides instructions for
setting up, creating and configuring RAID
sets using the available utilities.
RAID configuration
Chapter 6
6.1
Setting up RAID
The motherboard comes with the Intel® 3420 southbridge controller that supports
the following SATA RAID solutions:
•
•
LSI MegaRAID software RAID Configuration Utility (default) with RAID 0,
RAID 1, and RAID 10 support (for both Linux and Windows OS).
Intel Matrix Storage Manager with RAID 0, RAID 1, RAID 10, and RAID 5
support (for Windows OS only).
6.1.1
RAID definitions
RAID 0 (Data striping) optimizes two identical hard disk drives to read and write
data in parallel, interleaved stacks. Two hard disks perform the same work as a
single drive but at a sustained data transfer rate, double that of a single disk alone,
thus improving data access and storage. Use of two new identical hard disk drives
is required for this setup.
RAID 1 (Data mirroring) copies and maintains an identical image of data from one
drive to a second drive. If one drive fails, the disk array management software
directs all applications to the surviving drive as it contains a complete copy of
the data in the other drive. This RAID configuration provides data protection and
increases fault tolerance to the entire system. Use two new drives or use an
existing drive and a new drive for this setup. The new drive must be of the same
size or larger than the existing drive.
RAID 10 is data striping and data mirroring combined without parity (redundancy
data) having to be calculated and written. With the RAID 10 configuration you get
all the benefits of both RAID 0 and RAID 1 configurations. Use four new hard disk
drives or use an existing drive and three new drives for this setup.
RAID 5 stripes both data and parity information across three or more hard disk
drives. Among the advantages of RAID 5 configuration include better HDD
performance, fault tolerance, and higher storage capacity. The RAID 5 configuration
is best suited for transaction processing, relational database applications,
enterprise resource planning, and other business systems. Use a minimum of three
identical hard disk drives for this setup.
6.1.2
Installing hard disk drives
The motherboard supports SATA hard disk drives for RAID set configuration. For
optimal performance, install identical drives of the same model and capacity when
creating a disk array.
See section 2.4 Hard disk drives for SATA hard disk drive installation.
6-2
Chapter 6: RAID configuration
6.1.3
RAID controller selection
You can choose either the LSI Software RAID Configuration Utility or the Intel
Matrix Storage Manager as the default utility to create RAID set(s). See 5. RAID
configuration utility selection on page 4-6 for details.
6.1.4
Setting the RAID item in BIOS
You must set the RAID item in the BIOS Setup before you can create a RAID set
from SATA hard disk drives attached to the SATA connectors supported by
Intel® 3420 chipset. To do this:
1.
2.
3.
4.
Enter the BIOS Setup during POST.
Go to the Main menu > Storage Configuration, and then press <Enter>.
Set the Configure SATA as item to [RAID].
Press <F10> to save your changes and exit the BIOS Setup.
Refer to Chapter 5 for details on entering and navigating through the BIOS
Setup.
ASUS RS100-E6/PI2
6-3
6.2
SI Software RAID Configuration
L
Utility
The LSI MegaRAID software RAID configuration utility allows you to create RAID 0,
RAID 1, or RAID 10 set(s) from SATA hard disk drives connected to the SATA
connectors supported by the motherboard southbridge chip.
To enter the LSI MegaRAID software RAID configuration utility
1.
2.
Turn on the system after installing all the SATA hard disk drives.
During POST, the LSI MegaRAID software RAID configuration utility
automatically detects the installed SATA hard disk drives and displays any
existing RAID set(s). Press <Ctrl> + <M> to enter the utility.
LSI MegaRAID Software RAID BIOS Version A.09 04300936R
LSI SATA RAID Found at PCI Bus No: Dev No:1F
Device present at Port 0
ST3160812AS
152114MB
Device present at Port 1
ST3160812AS
152114MB
Device present at Port 2
ST3160812AS
152114MB
Device present at Port 3
ST3160812AS
152114MB
Press Ctrl-M or Enter to run LSI Software RAID Setup Utility.
3.
•
The LSI MegaRAID software RAID configuration utility automatically
configures to RAID 1 when the SATA to RAID Mode is enabled.
•
The RAID setup screens shown in this section are for reference only and
may not exactly match the items on your screen due to the controller
version difference.
•
When you create RAID sets with the LSI MegaRAID software RAID
configuration utility, the boot priority of the SATA optical drive has to be
manually adjusted. Otherwise, the system will not boot from the connected
SATA ODD.
The utility main window appears. Use the arrow keys to select an option from
the Management Menu and then press <Enter>. Refer to the Management
Menu descriptions on the next page.
At the bottom of the screen is the legend box. The keys on the legend box
allow you to navigate through the setup menu options or execute commands.
The keys on the legend box vary according to the menu level.
LSI Software RAID Configuration Utility Ver A.62 Apr 29, 2009
BIOS Version A.09.04300936R
Management Menu
Configure
Initialize
Objects
Rebuild
Check Consistency
Configure VD(s)
Use Cursor Keys to Navigate Between Items And Press Enter To Select An Option
6-4
Chapter 6: RAID configuration
Menu
Description
Configure
Allows you to create RAID 0, RAID 1 or RAID 10 set using the Easy
Configuration or the New Configuration command. This menu also
allows you to view, add, or clear RAID configurations or select the
boot drive
Initialize
Allows you to initialize the virtual drives of a created RAID set
Objects
Allows you to initialize virtual drives or change the virtual drive
parameters
Rebuild
Allows you to rebuild failed drives
Check Consistency Allows you to check the data consistency of the virtual drives of a
created RAID set
6.2.1
Creating a RAID set
The LSI Software RAID Configuration Utility allows you to create a RAID 0, RAID 1,
or RAID 10 set using two types of configurations: Easy and New.
In Easy Configuration, the virtual drive parameters are set automatically.
In New Configuration, you manually set the virtual drive parameters.
Using Easy Configuration
To create a RAID set using the Easy Configuration option
1.
From the Management Menu, select Configure > Easy Configuration, and
then press <Enter>.
LSI Software RAID Configuration Utility Ver A.62 Apr 29, 2009
BIOS Version A.09.04300936R
Configuration Menu
Easy Configuration
New Configuration
Management Menu
View/Add Configuration
Configure
Clear Configuration
Initialize
Select Boot Drive
Objects
Rebuild
Check Consistency
Defines Physical Arrays. An Array Will Automatically Become A VD
Use Cursor Keys to Navigate Between Items And Press Enter To Select An Option
ASUS RS100-E6/PI2
6-5
2.
The ARRAY SELECTION MENU displays the available drives connected to
the SATA ports. Use the up/down arrow key to select the drives you want to
include in the RAID set, and then press <Space>. When selected, the drive
indicator changes from READY to ONLIN A[X]-[Y], where X is the array
number, and Y is the drive number.
LSI Software RAID Configuration Utility Ver A.62 Apr 29, 2009
BIOS Version A.09.04300936R
Easy Configuration - ARRAY SELECTION MENU
Management Menu
Configure
Initialize
Objects
Rebuild
Check Consistency
PORT #
0 ONLIN A00-00
1 ONLIN A00-01
2 READY
3 READY
Port # 1 DISK
77247MB
HDS728080PLA380
PF20A60A
SPACE-Sel,ENTER-EndArray,F10-Configure,F2-Drive Info,F3-Virtual Drives,F4-HSP
3.
4.
•
The information of the selected hard disk drive displays at the bottom of the
screen.
•
You need at least two identical hard disk drives when creating a RAID 1 set.
•
You need at least four identical hard disk drives when creating a RAID 10
set.
Select all the drives required for the RAID set, and then press <F10> to
configure array setting.
Press <Space> to select the configurable array.
LSI Software RAID Configuration Utility Ver A.62 Apr 29, 2009
BIOS Version A.09.04300936R
Management Menu
Configure
Initialize
Objects
Rebuild
Check Consistency
Easy Configuration - ARRAY SELECTION MENU
Select Configurable Array(s)
PORT #
A-0
0 DNLIN A00-00
SPAN-1
1 DNLIN A00-01
Cursor Keys, SPACE-(De)Select F2-ChIdInfo F3-SlotInfo F10-Configure Esc-Quit
6-6
Chapter 6: RAID configuration
5.
Press <F10> again, the virtual drive information appears including a Virtual
Drive menu that allows you to change the virtual drive parameters.
LSI Software RAID Configuration Utility Ver A.62 Apr 29, 2009
BIOS Virtual
VersionDrive(s)
A.09.04300936R
Configured
LD
RAID
Size
#Stripes
StripSzMENU Status
Easy Configuration
- ARRAY SELECTION
0
1
77247MB
2
64 KB
ONLINE
Management Menu
PORT #
Configure
0 DNLIN A00-00
Initialize
Objects
1 DNLIN A00-01
Rebuild
Check Consistency
Virgual Drive 0
RAID = 1
Size = 77247MB
DWC = Off
RA = On
Accept
SPAN = NO
Choose RAID Level For This VD
Cursor Keys, SPACE-(De)Select F2-ChIdInfo F3-SlotInfo F10-Configure Esc-Quit
6.
7.
Select RAID from the Virtual Drive sub-menu, and then press <Enter>.
Select the RAID level from the menu, and then press <Enter>.
LSI Software RAID Configuration Utility Ver A.62 Apr 29, 2009
BIOS Virtual
VersionDrive(s)
A.09.04300936R
Configured
LD
RAID
Size
#Stripes
StripSzMENUStatus
Easy Configuration
- ARRAY SELECTION
0
1
77247MB
2
64 KB
ONLINE
Management Menu
PORT #
Configure
0 DNLIN A00-00
Initialize
Objects
1 DNLIN A00-01
Rebuild
Check Consistency
Virtual Drive 0
RAID Level
RAID = 1
RAID 0
Size = 77247MB
RAID 1
DWC = Off
RA = On
Accept
SPAN = NO
Choose RAID Level For This VD
Cursor Keys, SPACE-(De)Select F2-ChIdInfo F3-SlotInfo F10-Configure Esc-Quit
ASUS RS100-E6/PI2
6-7
8.
9.
When creating a RAID 1 or a RAID 10 set, select DWC from the Virtual
Drive menu, and then press <Enter>.
When creating a RAID 0 set, proceed to step 10.
Select On to enable the Disk Write Cache setting, and then press <Enter>.
LSI Software RAID Configuration Utility Ver A.62 Apr 29, 2009
BIOSVirtual
VersionDrive(s)
A.09.04300936R
Configured
LD
RAID
Size
#Stripes
StripSzMENUStatus
Easy Configuration
- ARRAY SELECTION
0
1
77247MB
2
64 KB
ONLINE
Management Menu
PORT #
Configure
0 DNLIN A00-00
Initialize
Objects
1 DNLIN A00-01Change DWC
Rebuild
Off
Check Consistency
On
Virtual Drive 0
RAID = 1
Size = 77247MB
DWC = Off
RA = On
Accept
SPAN = NO
Disk Write Cache Setting Of VD
Cursor Keys, SPACE-(De)Select F2-ChIdInfo F3-SlotInfo F10-Configure Esc-Quit
Enabling DWC can improve the performance, but with the risk of data loss.
10. When finished setting the selected virtual drive configuration, select Accept
from the menu, and then press <Enter>.
LSI Software RAID Configuration Utility Ver A.62 Apr 29, 2009
BIOS Virtual
VersionDrive(s)
A.09.04300936R
Configured
LD
RAID
Size
#Stripes
StripSzMENUStatus
Easy Configuration
- ARRAY SELECTION
0
1
77247MB
2
64 KB
ONLINE
Management Menu
PORT #
Configure
0 DNLIN A00-00
Initialize
Objects
1 DNLIN A00-01
Rebuild
Check Consistency
Virtual Drive 0
RAID = 1
Size = 77247MB
DWC = Off
RA = On
Accept
SPAN = NO
Accept This VD Configuration And Go To Next VD
Cursor Keys, SPACE-(De)Select F2-ChIdInfo F3-SlotInfo F10-Configure Esc-Quit
6-8
Chapter 6: RAID configuration
11. Follow step 2 to 10 to configure additional virtual drives.
12. Press <Esc> to finish RAID configuration. When prompted to save
configuration, select Yes from the menu, and then press <Enter>.
LSI Software RAID Configuration Utility Ver A.62 Apr 29, 2009
BIOS Version A.09.04300936R
Configuration Menu
Save Configuration?
Easy Configuration
Yes
New
Management Menu Configuration
No
View/Add Configuration
Configure
Clear Configuration
Initialize
Virtual Drive(s) Configured
Boot Drive
Objects
LD Select
RAID
Size
#Stripes
StripSz Status
Rebuild
0
1
77247MB
2
64 KB
ONLINE
Check Consistency
Select Yes Or No
Use Cursor Keys to Navigate Between Items And Press Enter To Select An Option
Using New Configuration
When a RAID set already exists, using the New Configuration command
erases the existing RAID configuration data. If you do not want to delete the
existing RAID set, use the View/Add Configuration command to view or create
another RAID configuration.
To create a RAID set using the New Configuration option
1.
From the Management Menu, select Configure > New Configuration, and
then press <Enter>.
LSI Software RAID Configuration Utility Ver A.62 Apr 29, 2009
BIOS Version A.09.04300936R
Configuration Menu
Easy Configuration
New Configuration
Management Menu
View/Add Configuration
Configure
Clear Configuration
Initialize
Select Boot Drive
Objects
Rebuild
Check Consistency
Clear Existing Configuration And Start A New Configuration
Use Cursor Keys to Navigate Between Items And Press Enter To Select An Option
ASUS RS100-E6/PI2
6-9
2.
Follow step 2 to 7 of the previous section: Using Easy Configuration.
4.
Key-in the desired virtual drive size, and then press <Enter>.
3.
Select Size from the Virtual Drive menu, and then press <Enter>.
LSI Software RAID Configuration Utility Ver A.62 Apr 29, 2009
BIOS Virtual
VersionDrive(s)
A.09.04300936R
Configured
LD
RAID
Size
#Stripes
StripSzMENUStatus
Easy Configuration
- ARRAY SELECTION
0
1
77247MB
2
64 KB
ONLINE
Management Menu
PORT #
Configure
0 DNLIN A00-00
Initialize
Objects
1 DNLIN A00-01
Rebuild
Check Consistency
Enter VD Size (MB): 77247
Virtual Drive 0
RAID = 1
Size = 77247MB
DWC = Off
RA = On
Accept
SPAN = NO
Enter VD Size (MB):
Use Cursor Keys to Navigate Between Items And Press Enter To Select An Option
5.
6-10
Follow step 8 to 12 of the previous section: Using Easy Configuration to
create the RAID set.
Chapter 6: RAID configuration
6.2.2
Adding or viewing a RAID configuration
You can add a new RAID configuration or view an existing configuration using the
View/Add Configuration command.
Adding a new RAID configuration
To add a new RAID configuration:
1.
From the Management Menu, select Configure > View/Add Configuration,
and then press <Enter>.
LSI Software RAID Configuration Utility Ver A.62 Apr 29, 2009
BIOS Version A.09.04300936R
Configuration Menu
Easy Configuration
New Configuration
Management Menu
View/Add Configuration
Configure
Clear Configuration
Initialize
Select Boot Drive
Objects
Rebuild
Check Consistency
View/Add to The Existing Configuration
Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option
2.
The ARRAY SELECTION MENU displays the available drives connected to
the SATA ports. Select the drive(s) you want to include in the RAID set, then
press <Space>. When selected, the drive indicator changes from READY to
ONLIN A[X]-[Y], where X is the array number, and Y is the drive number.
LSI Software RAID Configuration Utility Ver A.62 Apr 29, 2009
BIOS Version A.09.04300936R
View/Add Configuration - ARRAY SELECTION MENU
Management Menu
Configure
Initialize
Objects
Rebuild
Check Consistency
Port # 2 DISK
PORT #
0 ONLIN A00-00
1 ONLIN A00-01
2 READY
3 READY
77247MB
HDS728080PLA380
PF20A60A
SPACE-Sel,ENTER-EndArray,F10-Configure,F2-Drive Info,F3-Virtual Drives,F4-HSP
The information of the selected hard disk drive displays at the bottom of the
screen.
3.
Follow step 3 to 12 of section 6.2.1 Creating a RAID set: Using Easy
Configuration to add a new RAID set.
ASUS RS100-E6/PI2
6-11
6.2.3
Initializing the virtual drives
After creating the RAID set(s), you must initialize the virtual drives. You may
initialize the virtual drives of a RAID set(s) using the Initialize or Objects command
on the Management Menu.
Using the Initialize command
To initialize the virtual drive using the Initialize command
1.
From the Management Menu, select Initialize, and then press <Enter>.
LSI Software RAID Configuration Utility Ver A.62 Apr 29, 2009
BIOS Version A.09.04300936R
Management Menu
Configure
Initialize
Objects
Rebuild
Check Consistency
Initialize Virtual Drive(s)
Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option
2.
The screen displays the available RAID set(s) and prompts you to select the
virtual drive to initialize. Use the arrow keys to select the virtual drive from the
Virtual Drive selection, and then press <Space>.
LSI Software RAID Configuration Utility Ver A.62 Apr 29, 2009
BIOS Version A.09.04300936R
Management Menu
Configure
Initialize
Objects
Rebuild
Check Consistency
LD
RAID
0
1
Virtual Drive(s) Configured
Size
#Stripes
StripSz
Status
151634MB
ONLINE
2
64 KB
Virtual Drives
Virtual Drive 0
Select VD
SPACE-(De)Select, F10-Initialize
6-12
Chapter 6: RAID configuration
3.
Press <F10> to start initialization. When prompted, select Yes from the
Initialize? dialog box, and then press <Enter>.
LSI Software RAID Configuration Utility Ver A.62 Apr 29, 2009
BIOS Version A.09.04300936R
Management Menu
Configure
Initialize
Objects
Rebuild
Check Consistency
LD
0
Virtual Drive(s) Configured
RAID
Size
#Stripes
StripSz
10 154494MB
4
64 KB
Status
ONLINE
Initialize?
Yes
No
Virtual Drives
Virtual Drive 0
Init Will Destroy Data On Selected VD(s)
SPACE-(De)Select, F10-Initialize
Initializing a virtual drive erases all data on the drive.
4.
A progress bar appears on screen. If desired, press <Esc> to abort
initialization. When initialization is completed, press <Esc>.
LSI Software RAID Configuration Utility Ver A.62 Apr 29, 2009
BIOS Version A.09.04300936R
Virtual Drive(s) Configured
Management Menu
LD
RAID
Size
#Stripes
StripSz
Configure
0 Init10Of VD
154494MB
4
64 KB
Is In Process
Initialize
Objects
VD 0 Initialization Complete. Press Esc..
Rebuild
Check Consistency
Status
ONLINE
¦ 100% Completed
Virtual Drives
Virtual Drive 0
SPACE-(De)Select, F10-Initialize
ASUS RS100-E6/PI2
6-13
Using the Objects command
To initialize the virtual drives using the Objects command
1.
From the Management Menu, select Objects > Virtual Drive, and then
press <Enter>.
LSI Software RAID Configuration Utility Ver A.62 Apr 29, 2009
BIOS Version A.09.04300936R
Objects
Management Menu
Adapter
Configure
Virtual Drive
Initialize
Physical Drive
Objects
Rebuild
Check Consistency
Change VD Parameters
Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option
2.
Select the virtual drive to initialize from the Virtual Drives sub‑menu, and
then press <Enter>.
LSI Software RAID Configuration Utility Ver A.62 Apr 29, 2009
BIOS Version A.09.04300936R
Vitual Drive(1)
Virtual Drive 0
Objects
Management Menu
Adapter
Configure
Virtual Drive
Initialize
Physical Drive
Objects
Rebuild
Check Consistency
Select VD
Press ENTER To Select A VD, <Del> To Delete A VD
6-14
Chapter 6: RAID configuration
3.
Select Initialize from the pop-up menu, and then press <Enter> to start
initialization.
LSI Software RAID Configuration Utility Ver A.62 Apr 29, 2009
BIOS Version A.09.04300936R
Vitual Drive(1)
Virtual Drive 0
Objects
Management Menu
Adapter
Configure
Virtual Drive
Initialize
Physical Drive
Objects
Vitual Drive(0)
Rebuild
Initialze
Check Consistency
Check Consistency
View/Update Parameters
Initilize VD
Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option
4.
When prompted, press the <Space> to select Yes from the Initialize? dialog
box, and then press <Enter>.
LSI Software RAID Configuration Utility Ver A.62 Apr 29, 2009
BIOS Version A.09.04300936R
Vitual Drive(1)
Virtual Drive 0
Objects
Management Menu
Adapter
Configure
Virtual Drive
Initialize
Physical Drive
Objects
Vitual Drive(0)
Rebuild
Initialze
Check Consistency
Initialize?
Check Consistency
Yes
View/Update Parameters
No
Initilize Will Destroy Data On Selected VD(s)
Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option
5.
A progress bar appears on screen. If desired, press <Esc> to abort
initialization. When initialization is completed, press <Esc>.
ASUS RS100-E6/PI2
6-15
6.2.4
Rebuilding failed drives
You can manually rebuild failed hard disk drives using the Rebuild command in the
Management Menu.
To rebuild a failed hard disk drive
1.
From the Management Menu, select Rebuild, and then press <Enter>.
LSI Software RAID Configuration Utility Ver A.62 Apr 29, 2009
BIOS Version A.09.04300936R
Management Menu
Configure
Initialize
Objects
Rebuild
Check Consistency
Rebuild PD(s)
Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option
2.
The PHYSICAL DRIVES SELECTION MENU displays the available drives
connected to the SATA ports. Select the drive you want to rebuild, and then
press <Space>.
LSI Software RAID Configuration Utility Ver A.62 Apr 29, 2009
BIOS Version A.09.04300936R
REBUILD - PHYSICAL DRIVES SELECTION MENU
Management Menu
Configure
Initialize
Objects
Rebuild
Check Consistency
Port # 1 DISK
PORT #
0 ONLIN A00-00
1 FAIL A00-01
77247MB
HDS728080PLA380
PF20A60A
SPACE-(De)Select,F10-Start Rebuild,F2-Drive Information,F3-View Virtual Drives
6-16
Chapter 6: RAID configuration
3.
After selecting the drive to rebuild, press <F10>. When prompted, press <Y>
to rebuild the drive.
LSI Software RAID Configuration Utility Ver A.62 Apr 29, 2009
BIOS Version A.09.04300936R
REBUILD - PHYSICAL DRIVES SELECTION MENU
Management Menu
PORT #
Configure
0 ONLIN A00-00
Initialize
Objects
1 RBLD A00-01
Rebuild
Check Consistency
Rebuilding
Of Drive Will Take A Few Minutes. Start Rebuilding Drive (Y/N)?
Port # 1 DISK
77247MB
HDS728080PLA380
PF20A60A
SPACE-(De)Select,F10-Start Rebuild,F2-Drive Information,F3-View Virtual Drives
4.
When rebuild is complete, press any key to continue.
ASUS RS100-E6/PI2
6-17
6.2.5
Checking the drives for data consistency
You can check and verify the accuracy of data redundancy in the selected virtual
drive. The utility can automatically detect and/or detect and correct any differences
in data redundancy depending on the selected option in the Objects > Adapter
menu.
The Check Consistency command is available only for virtual drives included
in a RAID 1 or RAID 10 set.
Using the Check Consistency Command
To check data consistency using the Check Consistency command
1.
From the Management Menu, select Check Consistency, and then press
<Enter>.
LSI Software RAID Configuration Utility Ver A.62 Apr 29, 2009
BIOS Version A.09.04300936R
Management Menu
Configure
Initialize
Objects
Rebuild
Check Consistency
CC Of VD(s)
Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option
2.
The screen displays the available RAID set(s) and prompts you to select
the virtual drive to check. Press <Space> to select the virtual drive from the
Virtual Drive sub-menu, and then press <F10>.
LSI Software RAID Configuration Utility Ver A.62 Apr 29, 2009
BIOS Version A.09.04300936R
Management Menu
Configure
Initialize
Objects
Rebuild
Check Consistency
LD
0
Virtual Drive(s) Configured
RAID
Size
#Stripes
StripSz
10 154494MB
4
64 KB
Status
ONLINE
Virtual Drives
Virtual Drive 0
Select VD
SPACE-(De)Select,
6-18
F10-Check Consistency
Chapter 6: RAID configuration
3.
When prompted, use the arrow keys to select Yes from the Consistency
Check? dialog box, and then press <Enter>.
LSI Software RAID Configuration Utility Ver A.62 Apr 29, 2009
BIOS Version A.09.04300936R
Management Menu
Configure
Initialize
Objects
Rebuild
Check Consistency
LD
0
Virtual Drive(s) Configured
RAID
Size
#Stripes
StripSz
10 154494MB
4
64 KB
Yes
No
Status
ONLINE
Consistency Check?
Virtual Drives
Virtual Drive 0
Select VD
SPACE-(De)Select,
F10-Check Consistency
A progress bar appears on screen.
LSI Software RAID Configuration Utility Ver A.62 Apr 29, 2009
BIOS Version A.09.04300936R
Virtual Drive(s) Configured
Management Menu
LD
RAID
Size
#Stripes
StripSz
Configure
0
10
154494MB
64 KB
CC Under
Process 4
Initialize
Objects
VD 0 Consistency Check. Press Esc to Abort.
Rebuild
Check Consistency
Status
ONLINE
¦ 85 % Completed
Virtual Drives
Virtual Drive 0
The Data On The Drives Is Inconsistency. Repair Done!
SPACE-(De)Select,
4.
F10-Check Consistency
While checking the disk consistency, press <Esc> to display the following
options.
• Stop
- Stops the consistency check. The utility stores the
percentage of disk checked, and when you restart checking,
it continues from the last percentage completed rather than
from zero percent.
• Continue- Continues the consistency check.
• Abort
5.
When checking is complete, press any key to continue.
ASUS RS100-E6/PI2
- Aborts the consistency check. When you restart checking, it
continues from zero percent.
6-19
Using the Objects command
To check data consistency using the Objects command
1.
2.
3.
4.
5.
6-20
From the Management Menu, select Objects, and then select Virtual Drive
from the sub-menu.
Use the arrow keys to select the virtual drive you want to check, and then
press <Enter>.
Select Check Consistency from the pop-up menu, and then press <Enter>.
When prompted, use the arrow keys to select Yes from the dialog box to
check the drive.
When checking is complete, press any key to continue.
Chapter 6: RAID configuration
6.2.6
Deleting a RAID configuration
To delete a RAID configuration
1.
From the Management Menu, select Configure > Clear Configuration, and
then press <Enter>.
LSI Software RAID Configuration Utility Ver A.62 Apr 29, 2009
BIOS Version A.09.04300936R
Configuration Menu
Easy Configuration
New Configuration
Management Menu
View/Add Configuration
Configure
Clear Configuration
Initialize
Select Boot Drive
Objects
Rebuild
Check Consistency
Clear Existing Configuration
Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option
2.
When prompted, use the arrow keys to select Yes from the Clear
Configuration? dialog box, and then press <Enter>.
LSI Software RAID Configuration Utility Ver A.62 Apr 29, 2009
BIOS Version A.09.04300936R
Configuration Menu
Easy Configuration
New Configuration
Management Menu
Clear Configuration?
View/Add Configuration
Configure
Yes
Clear Configuration
Initialize
No Drive
Select Boot
Objects
Rebuild
Check Consistency
Clear Existing Configuration
Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option
3.
The utility clears all the current array(s).
Press any key to continue.
ASUS RS100-E6/PI2
6-21
6.2.7
Selecting the boot drive from a RAID set
You must have created a new RAID configuration before you can select the
boot drive from a RAID set. See section 6.2.1 Creating a RAID set: Using New
Configuration for details.
To select the boot drive from a RAID set
1.
From the Management Menu, select Configure > Select Boot Drive, and
then press <Enter>.
LSI Software RAID Configuration Utility Ver A.62 Apr 29, 2009
BIOS Version A.09.04300936R
Configuration Menu
Easy Configuration
New Configuration
Management Menu
View/Add Configuration
Configure
Clear Configuration
Initialize
Select Boot Drive
Objects
Rebuild
Check Consistency
Select A Boot VD
Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option
2.
When prompted, use the arrow keys to select the bootable virtual drive from
the list, then press <Enter>.
LSI Software RAID Configuration Utility Ver A.62 Apr 29, 2009
BIOS Version A.09.04300936R
Bootable VDs(1):Current Boot VD(0)
Configuration
BootMenu
Drive 0
Easy Configuration
New Configuration
Management Menu
View/Add Configuration
Configure
Clear Configuration
Initialize
Select Boot Drive
Objects
Rebuild
Check Consistency
Select A Boot VD
Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option
3.
6-22
The virtual drive is selected as boot drive. Press any key to continue.
Chapter 6: RAID configuration
6.2.8
Enabling WriteCache
You may manually enable the RAID controller’s WriteCache option after creating a
RAID set to improve the data transmission performance.
When you enable WriteCache, you may lose data when a power interruption occurs
while transmitting or exchanging data among the drives.
The WriteCache function is recommended for RAID 1 and RAID 10 sets.
To enable WriteCache
1.
2.
From the Management Menu, select Objects > Adapter, and then press
<Enter> to display the adapter properties.
Select Disk WC, and then press <Enter> to turn on the option.
LSI Software RAID Configuration Utility Ver A.62 Apr 29, 2009
BIOS Version A.09.04300936R
Adapter 0
Rebuild Rate = 30
ObjectsChk Const Rate = 30
Management Menu
Adapter
FGI Rate
= 30
Configure
Virtual Drive BGI Rate
= 30
Initialize
Physical DriveDisk WC
= Off
Objects
Read Ahead
= On
Rebuild
Bios State
= Enable
Check Consistency
Stop On Error = No
Fast Init
= Enable
Auto Rebuild = On
Auto Resume
= Enable
Disk Coercion = 1GB
Factory Default
Disk Write Cache - Off(Write Through) or On(Write Back)
Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option
3.
4.
From the Management Menu, select Objects > Virtual Drive, and then
press <Enter> to display the adapter properties.
Select Disk WC, and then press <Enter> to turn on the option.
LSI Software RAID Configuration Utility Ver A.62 Apr 29, 2009
BIOS Version A.09.04300936R
Virtual Drive
RAID
= 0
Objects
Size
= 1428604MB
Management Menu
Adapter
Stripe Size = 64KB
Configure
Virtual Drive
#Stripes
= 2
Initialize
Physical Drive
State
= OPTIMAL
Objects
Spans
= 1
Rebuild
Disk WC
= On
Check Consistency
Read Ahead
= On
Disk Write Cache - Off(Write Through) or On(Write Back)
Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option
5.
When finished, press any key to continue.
ASUS RS100-E6/PI2
6-23
6.3Intel® Matrix Storage Manager Option
ROM Utility
The Intel® Matrix Storage Manager Option ROM utility allows you to create RAID 0,
RAID 1, RAID 10 (RAID 1+0), and RAID 5 set(s) from Serial ATA hard disk drives
that are connected to the Serial ATA connectors supported by the Southbridge.
To enter the Intel® Matrix Storage Manager option ROM utility:
1.
Install all the Serial ATA hard disk drives.
3.
During POST, press <Ctrl+I> to display the utility main menu.
2.
Turn on the system.
Intel(R) Matrix Storage Manager option ROM v8.9.0.1023 PCH-D wRAID5
Copyright(C) 2003-09 Intel Corporation. All Rights Reserved.
[ MAIN MENU ]
1. Create RAID Volume
2. Delete RAID Volume
5. Exit
3. Reset Disks to Non-RAID
4. Recovery Volume Options
[ DISK/VOLUME INFORMATION ]
RAID Volumes:
None defined.
Physical Disks:
Port Drive Model
0
ST3160812AS
1
ST3160812AS
2
ST3160812AS
3
ST3160812AS
[↑↓]-Select
* = Data is Encrypted
Serial #
9LS0HJA4
9LS0F4HL
3LS0JYL8
9LS0BJ5H
[ESC]-Exit
Size
149.0GB
149.0GB
149.0GB
149.0GB
Type/Status(Vol ID)
Non-RAID Disk
Non-RAID Disk
Non-RAID Disk
Non-RAID Disk
[ENTER]-Select Menu
The navigation keys at the bottom of the screen allow you to move through
the menus and select the menu options.
The RAID BIOS setup screens shown in this section are for reference only and
may not exactly match the items on your screen.
6-24
Chapter 6: RAID configuration
6.3.1
Creating a RAID set
To create a RAID set
1.
From the utility main menu, select 1. Create RAID Volume and press
<Enter>. The following screen appears.
Intel(R) Matrix Storage Manager option ROM v8.9.0.1023 PCH-D wRAID5
Copyright(C) 2003-09 Intel Corporation. All Rights Reserved.
[ CREATE VOLUME MENU ]
Name:
RAID Level:
Disks:
Strip Size:
Capacity:
Sync:
Volume0
RAID0(Stripe)
Select Disks
128KB
0.0
GB
N/A
Create Volume
[ HELP ]
Enter a unique volume name that has no special characters and is
16 characters or less.
[↑↓]Change
[TAB]-Next
[ESC]-Previous Menu
[ENTER]-Select
2.
Enter a name for the RAID set and press <Enter>.
4.
When the Disks item is selected, press <Enter> to select the hard disk drives
you want to include in the RAID set. The SELECT DISKS screen appears.
3.
When the RAID Level item is selected, press the up/down arrow key to select
a RAID level to create, and then press <Enter>.
[ SELECT DISKS ]
Port
0
1
2
3
Drive Model
ST3160812AS
ST3160812AS
ST3160812AS
ST3160812AS
Serial #
9LS0HJA4
9LS0F4HL
3LS0JYL8
9LS0BJ5H
Size
149.0GB
149.0GB
149.0GB
149.0GB
Status
Non-RAID
Non-RAID
Non-RAID
Non-RAID
Disk
Disk
Disk
Disk
Select 2 to 6 disks to use in creating the volume.
[↑↓]-Prev/Next [SPACE]-SelectDisk [ENTER]-Done
5.
Use the up/down arrow key to select a drive, and then press <Space>
to select. A small triangle marks the selected drive. Press <Enter> after
completing your selection.
ASUS RS100-E6/PI2
6-25
6.
Use the up/down arrow key to select the stripe size for the RAID array (for
RAID 0, 10 and 5 only), and then press <Enter>. The available stripe size
values range from 4 KB to 128 KB. The following are typical values:
RAID 0: 128KB
RAID 10: 64KB
RAID 5: 64KB
We recommend a lower stripe size for server systems, and a higher stripe size
for multimedia computer systems used mainly for audio and video editing.
7.
8.
When the Capacity item is selected, enter the RAID volume capacity that you
want and press <Enter>. The default value indicates the maximum allowed
capacity.
When the Create Volume item is selected, press <Enter>. The following
warning message appears.
WARNING: ALL DATA ON SELECTED DISKS WILL BE LOST.
Are you sure you want to create this volume? (Y/N):
9.
Press <Y> to create the RAID volume and return to the main menu, or <N> to
go back to the CREATE VOLUME menu.
6.3.2
Creating a Recovery set
To create a recovery set
1.
From the utility main menu, select 1. Create RAID Volume and press
<Enter>. The following screen appears.
Intel(R) Matrix Storage Manager option ROM v8.9.0.1023 PCH-D wRAID5
Copyright(C) 2003-09 Intel Corporation. All Rights Reserved.
[ CREATE VOLUME MENU ]
Name:
RAID Level:
Disks:
Strip Size:
Capacity:
Sync:
Volume0
RAID0(Stripe)
Select Disks
128KB
0.0
GB
N/A
Create Volume
[ HELP ]
Enter a unique volume name that has no special characters and is
16 characters or less.
[↑↓]Change
6-26
[TAB]-Next
[ESC]-Previous Menu
[ENTER]-Select
Chapter 6: RAID configuration
2.
3.
4.
Enter a name for the recovery set and press <Enter>.
When the RAID Level item is selected, press the up/down arrow key to select
Recovery, and then press <Enter>.
When the Disks item is selected, press <Enter> to select the hard disk drives
you want to include in the recovery set. The SELECT DISKS screen appears.
[ SELECT DISKS ]
Port
0
1
2
3
Drive Model
ST3160812AS
ST3160812AS
ST3160812AS
ST3160812AS
Serial #
9LS0HJA4
9LS0F4HL
3LS0JYL8
9LS0BJ5H
Size
149.0GB
149.0GB
149.0GB
149.0GB
Status
Non-RAID
Non-RAID
Non-RAID
Non-RAID
Disk
Disk
Disk
Disk
Select 1 Master and 1 Recovery disk to create volume.
[↑↓]-Prev/Next [TAB]-(M)aster [SPACE]-(R)ecovery [ENTER]-Done
5.
6.
7.
Use the up/down arrow key to select a drive, press <TAB> to select a Master
disk, and then press <SPACE> to select a Recovery disk. A small triangle
marks the selected drive. Press <Enter> after completing your selection.
When the Sync item is selected, use the up/down arrow key to select a sync
option that you want and press <Enter>.
When the Create Volume item is selected, press <Enter>. The following
warning message appears.
WARNING: ALL DATA ON SELECTED DISKS WILL BE LOST.
Are you sure you want to create this volume? (Y/N):
8.
Press <Y> to create the recovery set and return to the main menu, or <N> to
go back to the CREATE VOLUME menu.
If a recovery set is created, you cannot add more RAID sets even when you
have more non-RAID disks installed in your system.
ASUS RS100-E6/PI2
6-27
6.3.3
Deleting a RAID set
Take caution when deleting a RAID set. You will lose all data on the hard disk
drives when you delete a RAID set.
To delete a RAID set
1.
From the utility main menu, select 2. Delete RAID Volume and press
<Enter>. The following screen appears.
Intel(R) Matrix Storage Manager option ROM v8.9.0.1023 PCH-D wRAID5
Copyright(C) 2003-09 Intel Corporation. All Rights Reserved.
[ DELETE VOLUME MENU ]
Name
Volume0
Level
RAID0(Stripe)
Drives
2
Capacity
298.0GB
Status
Normal
Bootable
Yes
[ HELP ]
Deleting a volume will reset the disks to non-RAID.
WARNING: ALL DISK DATA WILL BE DELETED.
(This does not apply to Recovery volumes)
[↑↓]-Select
2.
[ESC]-Previous Menu
[DEL]-Delete Volume
Use the up/down arrow key to select the RAID set you want to delete, and
then press <Del>. The following warning message appears.
[ DELETE VOLUME VERIFICATION ]
ALL DATA IN THE VOLUME WILL BE LOST!
(This does not apply to Recovery volumes)
Are you sure you want to delete volume “Volume0”? (Y/N):
3.
6-28
Press <Y> to delete the RAID set and return to the utility main menu, or press
<N> to return to the DELETE VOLUME menu.
Chapter 6: RAID configuration
6.3.4
Resetting disks to Non-RAID
Take caution before you reset a RAID volume hard disk drive to non-RAID.
Resetting a RAID volume hard disk drive deletes all internal RAID structure on
the drive.
To reset a RAID set hard disk drive
1.
From the utility main menu, select 3. Reset Disks to Non-RAID and press
<Enter>. The following screen appears.
[ RESET RAID DATA ]
Resetting RAID disk will remove its RAID structures
and revert it to a non-RAID disk.
WARNING: Resetting a disk causes all data on the disk to be lost.
(This does not apply to Recovery volumes)
Port Drive Model
0
ST3160812AS
1
ST3160812AS
Serial #
9LS0HJA4
9LS0F4HL
Size
149.0GB
149.0GB
Status
Member Disk
Member Disk
Select the disks that should be reset.
[↑↓]-Previous/Next
2.
3.
4.
[SPACE]-Selects [ENTER]-Selection Complete
Use the up/down arrow key to select the RAID set drive(s) you want to reset,
and then press <Space> to select.
Press <Enter> to reset the RAID set drive(s). A confirmation message
appears.
Press <Y> to reset the drive(s) or press <N> to return to the utility main
menu.
ASUS RS100-E6/PI2
6-29
6.3.5
Recovery Volume Options
If you have created a recovery set, you can configure more recovery set options
following the descriptions in the section.
See section 6.3.2 Creating a Recovery set to create a recovery set before
continue.
To configure a recovery set
1.
From the utility main menu, select 4. Recovery Volume Options and press
<Enter>. The following screen appears.
Intel(R) Matrix Storage Manager option ROM v8.9.0.1023 PCH-D wRAID5
Copyright(C) 2003-09 Intel Corporation. All Rights Reserved.
[ RECOVERY VOLUME OPTIONS ]
1.
2.
Enable Only Recovery Disk
Enable Only Master Disk
[ HELP ]
Enable Only Recovery Disk - enables recovery disk if available and
disables master disk.
Enable Only Master Disk - enables master disk if available and
disables recovery disk.
Actions will result in change from Continuous Update mode to On-Request.
[↑↓]-Select
2.
[ESC]-Previous Menu
[ENTER]-Select
Use the up/down arrow key to select the option you want, and then press
<ENTER>. The SELECT RECOVERY VOLUME screeen appears.
[ SELECT RECOVERY VOLUME ]
Name
Volume0
Level
Capacity
Status
Recovery(Cont.)
149.0GB
Normal
Bootable
Yes
Select a Recovery volume to do the operation.
[↑↓]-Up/Down [SPACE]-Selects [ENTER]-Done
3.
6-30
Use the up/down arrow key to select a drive, and then press <Space>
to select. A small triangle marks the selected drive. Press <Enter> after
completing your selection and return to the utility main menu.
Chapter 6: RAID configuration
6.3.6
Exiting the Intel® Matrix Storage Manager
To exit the utility
1.
From the utility main menu, select 5. Exit, and then press <Enter>. The
following warning message appears.
[ CONFIRM EXIT ]
Are you sure you want to exit? (Y/N):
2.
Press <Y> to exit or press <N> to return to the utility main menu.
6.3.7
Rebuilding the RAID
This option is only for the RAID 1 set.
Rebuilding the RAID with other non-RAID disk
If any of the SATA hard disk drives included in the RAID 1 array failed, the system
displays the status of the RAID volume as “Degraded” during POST. You can
rebuild the RAID array with other installed non-RAID disks.
To rebuild the RAID with other non-RAID disk:
1.
2.
At the prompt, press <Ctrl> + <I> to enter the Intel Matrix Storage Manager
option ROM utility.
If there is a non-RAID SATA Hard Disk available, the utility will prompt to
rebuild the RAID. Press <Enter>, and then use up/down arrow keys to select
the destination disk or press <ESC> to exit.
[ DEGRADED VOLUME DETECTED ]
"Degraded" volume and disk available for rebuilding detected. Selecting
a disk initiates a rebuild. Rebuild completes in the operating system.
Select the port of destination disk for rebuilding (ESC to exit):
Port Drive Model
Serial #
Size
X
XXXXXXXXXXX
XXXXXXXX
XX.XGB
[↑↓]-Previous/Next
[ENTER]-Select
[ESC]-Exit
Select a destination disk with the same size as the original hard disk.
ASUS RS100-E6/PI2
6-31
3.
The utility immediately starts rebuilding after the disk is selected. The status
of the degraded RAID volume is changed to “Rebuild”.
Intel(R) Matrix Storage Manager option ROM v8.9.0.1023 PCH-D wRAID5
Copyright(C) 2003-09 Intel Corporation. All Rights Reserved.
[ MAIN MENU ]
1. Create RAID Volume
2. Delete RAID Volume
3. Reset Disks to Non-RAID
4. Recovery Volume Options
5. Exit
[ DISK/VOLUME INFORMATION ]
RAID Volumes:
ID
Name
0
Volume0
Physical Disks:
Port Drive Model
1
ST3160812AS
2
ST3160812AS
5.
6.
7.
Strip
N/A
Serial #
9LS0F4HL
3LS0JYL8
Size
149.0GB
Size
149.0GB
149.0GB
* = Data is Encrypted
Status
Bootable
Rebuild
Yes
Type/Status(Vol ID)
Member Disk(0)
Member Disk(0)
Volumes with “Rebuild” status will be rebuilt within the operating system.
[↑↓]-Select
4.
Level
RAID1(Mirror)
[ESC]-Exit
[ENTER]-Select Menu
Exit Intel Matrix Storage Manager and reboot the system.
Select Start > Programs > Intel Matrix Storage > Intel Matrix Storage
Console or click the Intel Matrix Storage Manager tray icon to load the Intel
Matrix Stroage Manager utility.
From the View menu, select Advanced Mode to display the details of the
Intel Matrix Storage Console.
From the Volumes view option, select RAID volume to view the rebuilding
status. When finished, the status is changed to “Normal”.
Rebuilding the RAID with a new hard disk
If any of the SATA hard disk drives included in the RAID array failed, the system
displays the status of the RAID volume as “Degraded” during POST. You may
replace the disk drive and rebuild the RAID array.
To rebuild the RAID with a new hard disk:
1.
Remove the failed SATA hard disk and install a new SATA hard disk of the
same specification into the same SATA Port.
Select a destination disk with the same size as the original hard disk.
2.
6-32
Reboot the system and then follow the steps in section Rebuilding the RAID
with other non-RAID disk on page 6-31.
Chapter 6: RAID configuration
6.3.8
Setting the Boot array in the BIOS Setup Utility
You can set the boot priority sequence in the BIOS for your RAID arrays when
creating multi-RAID using the Intel® Matrix Storage Manager.
To set the boot array in the BIOS:
Set at least one of the arrays bootable to boot from the hard disk.
1.
2.
3.
4.
5.
Reboot the system and press <Del> to enter the BIOS setup utility during
POST.
Go to the Boot menu and select the option Boot Device Priority.
Use up/down arrow keys to select the boot priority and press <Enter>. See
section 5.7.1 Boot Device Priority for details.
From the Exit menu, select Exit & Save Changes, then press <Enter>.
When the confirmation window appears, select OK, then press <Enter>.
ASUS RS100-E6/PI2
6-33
6-34
Chapter 6: RAID configuration
This chapter provides instructions for
installing the necessary drivers for
different system components.
Driver installation
Chapter 7
7.1
RAID driver installation
After creating the RAID sets for your server system, you are now ready to install
an operating system to the independent hard disk drive or bootable array. This
part provides instructions on how to install the RAID controller drivers during OS
installation.
7.1.1
Creating a RAID driver disk
The system does not include a floppy drive. You have to use a USB floppy drive
when creating a SATA RAID driver disk.
If you have created RAID sets with the LSI Software RAID configuration utility,
the boot priority of the SATA optical disk drive has to be manually adjusted.
Otherwise, the system will not boot from the connected SATA ODD.
A floppy disk with the RAID driver is required when installing Windows® or
Red Hat® Enterprise operating system on a hard disk drive that is included in
a RAID set. You can create a RAID driver disk in DOS (using the Makedisk
application in the support DVD).
To create a RAID driver disk in DOS environment
1.
Place the motherboard support DVD in the optical drive.
3.
Select the optical drive as the first boot priority to boot from the support DVD.
Save your changes, and then exit the BIOS Setup.
2.
4.
Restart the computer, and then enter the BIOS Setup.
Restart the computer. The Makedisk menu appears.
Create Driver Diskette Menu
PCH INTEL RAID Driver
PCH LSI RAID Driver
Marvell 88SE6145 SATA RAID Driver
Marvell 88SE6145 SATA Non-RAID Driver
Write DMI
FreeDOS command prompt
5.
Use the arrow keys to select the type of RAID driver disk you want to create
and press <Enter> to enter the sub-menu.
PCH INTEL RAID Driver
PCH INTEL RAID Driver
Windows 32 bit(also support AHCI)
Windows 64 bit(also support AHCI)
Back
Exit
7-2
Chapter 7: Driver installation
PCH LSI RAID Driver
PCH LSI RAID Driver
Windows XP 32 bit
Windows XP 64 bit
Windows Server 2003 32
Windows Server 2003 64
Windows Vista 32 bit
Windows Vista 64 bit
Windows Server 2008 32
Windows Server 2008 64
RHEL AS4 UP5 32/64 bit
RHEL AS4 UP6 32/64 bit
RHEL AS4 UP7 32/64 bit
RHEL AS4 UP8 32/64 bit
RHEL 5 32/64 bit
RHEL 5 UP1 32/64 bit
RHEL 5 UP2 32/64 bit
RHEL 5 UP3 32/64 bit
SLES 9 SP3 32 bit
SLES 9 SP3 64 bit
SLES 9 SP4 32 bit
SLES 9 SP4 64 bit
SLES 10 32 bit
SLES 10 64 bit
6.
7.
8.
bit
bit
bit
bit
Locate the RAID driver and place a blank, high-density floppy disk to the
floppy disk drive.
Press <Enter>.
Follow screen instructions to create the driver disk.
ASUS RS100-E6/PI2
7-3
To create a RAID driver disk in Windows® environment
1. Start Windows®.
2. Place the motherboard support DVD into the optical drive.
3. Go to the Make Disk menu, and then select the type of RAID driver disk you
want to create.
4. Insert a floppy disk into the floppy disk drive.
5. Follow succeeding screen instructions to complete the process.
Write-protect the floppy disk to avoid computer virus infection.
To create a RAID driver disk in Red Hat® Enterprise Linux server environment
1.
2.
Insert a blank formatted high-density floppy disk to the floppy disk drive.
Type dd if=XXX.img of=/dev/fd0 to decompress the file into the floppy
disk from the following path in the support DVD:
For LSI MegaRAID Driver
\Drivers\PCH LSI RAID\Driver\makedisk\Linux
3. Eject the floppy disk.
7-4
Chapter 7: Driver installation
7.1.2
Installing the RAID controller driver
Windows® Server OS
During Windows® Server OS installation
To install the RAID controller driver when installing Windows® Server OS:
1.
Boot the computer using the Windows® Server installation DVD. The
Windows® Server OS Setup starts.
Windows Setup
Press F6 if you need to install a third party SCSI or RAID driver...
2.
3.
Press <F6> when the message “Press F6 if you need to install a third party
SCSI or RAID driver...” appears at the bottom of the screen.
When prompted, press <S> to specify an additional device.
Windows Setup
Setup could not determine the type of one or more mass storage devices
installed in your system, or you have chosen to manually specify an adapter.
Currently, Setup will load support for the following mass storage devices(s):
<none>
* To specify additional SCSI adapters, DVD-ROM drives, or special
disk controllers for use with Windows, including those for
which you have a device support disk from a mass storage device
manufacturer, press S.
* If you do not have any device support disks from a mass storage
device manufacturer, or do not want to specify additional
mass storage devices for use with Windows, press ENTER.
S=Specify Additional Device
ASUS RS100-E6/PI2
ENTER=Continue
F3=Exit
7-5
4.
Insert the RAID driver disk you created earlier to the floppy disk drive, then
press <Enter>.
Windows Setup
Please insert the disk labeled
Manufacturer-supplied hardware support disk
into Drive A:
*
ENTER=Continue
ESC=Cancel
Press ENTER when ready.
F3=Exit
5.
Select the RAID controller driver you need from the list, then press <Enter>.
7.
Setup then proceeds with the OS installation. Follow screen instructions to
continue.
6.
The Windows® Setup loads the RAID controller drivers from the RAID driver
disk. When prompted, press <Enter> to continue installation.
To an existing Windows® Server OS
To install the RAID controller driver on an existing Windows® Server OS
1.
2.
3.
4.
5.
6.
Restart the computer, and then log in with Administrator privileges.
Windows® automatically detects the RAID controller and displays a New
Hardware Found window. Click Cancel.
Right-click the My Computer icon on the Windows® desktop, and then select
Properties from the menu.
Click the Hardware tab, and then click the Device Manager button to display
the list of devices installed in the system.
Right-click the RAID controller item, then select Properties.
Click the Driver tab, and then click the Update Driver button.
7.
The Upgrade Device Driver Wizard window appears. Click Next.
9.
Select the option Install the software automatically (Recommended), and
then click Next.
8.
Insert the RAID driver disk you created earlier to the floppy disk drive.
10. The wizard searches the RAID controller drivers. When found, click Next to
install the drivers.
11. Click Finish after the driver installation is done.
7-6
Chapter 7: Driver installation
To verify the RAID controller driver installation:
1.
2.
3.
Right-click the My Computer icon on the Windows® desktop, and then select
Properties from the menu.
Click the Hardware tab, and then click the Device Manager button.
Click the “+” sign before the item SCSI and RAID controllers, and then the
Intel(R) ICH8R/ICH9R/ICH10R/DO/PCH SATA RAID Controller item should
appear.
The screen differs based on the controller.
4.
5.
6.
Right-click the RAID controller driver item, and then select Properties from
the menu.
Click the Driver tab, and then click the Driver Details button to display the
RAID controller drivers.
Click OK when finished.
ASUS RS100-E6/PI2
7-7
Red Hat® Enterprise Linux OS 4.7/4.8
To install the RAID controller driver when installing Red Hat® Enterprise OS:
1.
Boot the system from the Red Hat® OS installation CD.
3.
Press <Enter>.
2.
At the boot:, type linux dd nostorage.
- To install or upgrade in graphical mode, press the <ENTER> key.
- To install or upgrade in text mode, type: linux text <ENTER>.
- Use the function keys listed below for more information.
[F1-Main] [F2-Options] [F3-General] [F4-Kernel] [F5-Rescue]
boot: linux dd nostorage
4.
Select Yes using the <Tab> key when asked if you have the driver disk, then
press <Enter>.
Main Menu
Do you have a driver disk?
Yes
5.
No
Press <Enter> to continue.
Insert Driver Disk
Insert your driver disk into /dev/sda
and press “OK” to continue.
OK
7-8
Cancel
Chapter 7: Driver installation
6.
Select No and press <Enter> to continue.
More Driver Disks?
Do you wish to load any more
driver disks?
Yes
7.
No
Select your desired language and press <Enter> to continue.
Choose a Language
What language would you like to use
during the installation process?
Catalan
Chinese(Simplified)
Chinese(Traditional)
Croatian
Czech
Danish
Dutch
English
#
OK
8.
Select your keyboard type and press <Enter> to continue.
Keyboard Type
What type of keyboard do you have?
trq
ua
ua-utf
ua-utf-ws
uk
unicode
us
OK
ASUS RS100-E6/PI2
#
Back
7-9
9.
Select the media and press <tab> to select OK. Press<Enter> to continue.
Installation Method
What type of media contains the
packages to be installed?
Local CDROM
Hard drive
NFS image
FTP
HTTP
OK
Back
10. Select the media and press <tab> to select OK. Press <Enter> to continue.
No driver found
Unable to find any devices of the type
needed for this installation type.
Would you like to manually select your
driver or use a driver disk?
Select driver
7-10
Use a driver disk
Back
Chapter 7: Driver installation
11. Scroll down to locate the driver and press <Enter> to continue.
Select Device Driver to Load
Please select the driver below which you wish to load. If
it does not appear and you have a driver disk, press F2.
LSI Logic Fusion MPT SPI Driver (mptspi)
LSI MegaRAID Controllers (megaraid_mbox)
LSI MegaRAID Controllers (megaraid_sas)
LSI megasr Driver ver 13.10.0708.2009 (megasr)
Marvell SATA controllers (sata_mv)
Mylex DAC960 RAID Controller (DAC960)
[] Specify optional module arguments
OK
Back
The driver version may vary with time and model. Select LSI Mega Software
RAID driver (LSI megasr Driver) all the time.
12. Select Skip and press <Enter> to continue.
CD Found
To begin testing the CD media before
installation press OK.
Choose Skip to skip the media test
and start the installation.
OK
ASUS RS100-E6/PI2
Skip
7-11
13. Select Done and press <Enter> to continue.
Devices
The following devices have been found on your system.
Intel Pro/1000 (e1000e)
LSI megasr Driver ver 13.10.0708.2009 (megasr)
USB Mass Storage driver for Linux (usb-storage)
Done
Add Device
The displayed devices may vary with models and systems.
14. Follow the onscreen instructions to finish installing the RedHat operating
system.
7-12
Chapter 7: Driver installation
Red Hat® Enterprise Linux OS 5.0
To install the RAID controller driver when installing Red Hat® Enterprise OS:
1.
2.
3.
Boot the system from the Red Hat® OS installation CD.
At the boot:, type linux dd noprobe=ata[n]. The number of ata varies with
the hard disk drive number you have when building a RAID set. For example, if
you want to build a RAID set with 6 hard disk drives, type command line: linux
dd noprobe=ata1 noprobe=ata2 noprobe=ata3 noprobe=ata4 noprobe=ata5
noprobe=ata6.
Press <Enter>.
- To install or upgrade in graphical mode, press the <ENTER> key.
- To install or upgrade in text mode, type: linux text <ENTER>.
- Use the function keys listed below for more information.
[F1-Main] [F2-Options] [F3-General] [F4-Kernel] [F5-Rescue]
boot: linux dd noprobe=ata[n]
4.
Select Yes using the <Tab> key when asked if you have the driver disk, then
press <Enter>.
Main Menu
Do you have a driver disk?
Yes
5.
No
Select fd0 using the <Tab> key when asked to select the driver disk source.
Press <Tab> to move the cursor to OK, then press <Enter>.
Driver Disk Source
You have multiple devices which could
serve as sources for a driver disk.
Which would you like to use?
fd0
scd0
OK
ASUS RS100-E6/PI2
Cancel
7-13
6.
Insert the Red Hat® Enterprise RAID driver disk to the floppy disk drive, select
OK, then press <Enter>.
Insert Driver Disk
Insert your driver disk into /dev/fd0
and press “OK” to continue.
OK
Back
The drivers for the RAID card are installed to the system.
7.
When asked if you will load additional RAID controller drivers, select No, then
press <Enter>.
More Driver Disks?
Do you wish to load any more
driver disks?
Yes
8.
9.
No
Follow the onscreen instructions to finish the OS installation.
If you install RHEL AS5, when the installation is completed, DO NOT click
Reboot. Press <Ctrl> + <Alt> + <F2> to switch to the command-line interface
from graphic user interface.
10. Type the following commands when using a USB floppy.
cat /proc/partitions
Write down the Major and Minor number before sdb for later use.
7-14
mknod /dev/sdb b [major number] [minor number]
mkdir /mnt/driver
mount /dev/sdb /mnt/driver
cd /mnt/driver
sh replace_ahci.sh
reboot
Chapter 7: Driver installation
SUSE Linux OS
To install the RAID controller driver when installing SUSE Linux Enterprise Server
OS:
1.
2.
Boot the system from the SUSE OS installation CD.
Use the arrow keys to select Installation from the Boot Options menu.
Boot from Hard Disk
Installation
Installation--ACPI Disabled
Installation--Local APIC Disabled
Installation--Safe Settings
Rescue System
Memory Test
Boot Options |
F1 Help F2 Language F3 1280 x 1024 F4 DVD F5 Driver
3.
Press <F5>, then select Yes from the menu. Press <Enter>.
Boot from Hard Disk
Installation
Installation--ACPI Disabled
Installation--Local APIC Disabled
Installation--Safe Settings
Rescue System
Memory Test
Yes
No
File
F1 Help F2 Language F3 1280 x 1024 F4 DVD F5 Driver
Boot Options |
ASUS RS100-E6/PI2
7-15
4.
Insert the RAID driver disk to the floppy disk drive. Make sure that Installation
from the Boot Options menu is selected, then press <Enter>.
Boot from Hard Disk
Installation
Installation--ACPI Disabled
Installation--Local APIC Disabled
Installation--Safe Settings
Rescue System
Memory Test
Boot Options |
F1 Help F2 Language F3 1280 x 1024 F4 DVD F5 Driver
If you install SLES 10, type brokenmodules=ahci after Boot Options and
press Enter to continue.
5.
When below screen appears, select the floppy disk drive (fd0) as the driver
update medium. Select OK, then press <Enter>.
Please choose the Driver Update medium.
fd0: Floppy
sr0: CD-ROM, TEAC DV-516E
sda: Disk, SEAGATE ST336754SS
sdb: Disk, SEAGATE ST336754SS
Other device
OK
7-16
Back
The drivers for the RAID controller are installed to the system.
Chapter 7: Driver installation
7.2
Intel® chipset device installation
This section provides instructions on how to install the Plug and Play components
for the Intel® chipset on the system.
You need to manually install the Intel® chipset software on a Windows Server
operating system. To install the Intel® chipset device software:
1.
2.
3.
4.
Restart the computer, then log on with Administrator privileges.
Insert the motherboard/system support DVD to the optical drive. The support
DVD automatically displays the Drivers menu if Autorun is enabled in your
computer.
Click the item Intel Chipset Device Software from the menu.
The Intel(R) Chipset Device Software window appears. Click Next to start
installation.
ASUS RS100-E6/PI2
7-17
7-18
5.
Select Yes to accept the terms of the License Agreement and continue the
process.
6.
Read the Readme File Information and press Next to continue the
installation.
7.
After completing the installation, click Finish to complete the setup process.
Chapter 7: Driver installation
7.3
LAN driver installation
This section provides instructions on how to install the Intel® Gigabit LAN controller
drivers on a Windows® Server OS.
To install the LAN controller drivers
1.
2.
Restart the computer, and then log on with Administrator privileges.
Insert the motherboard/system support DVD to the optical drive. The DVD
automatically displays the Drivers menu if Autorun is enabled in your
computer.
•
Windows® automatically detects the LAN controllers and displays a New
Hardware Found window. Click Cancel to close this window.
•
If Autorun is NOT enabled in your computer, browse the contents of the
support DVD to locate the file ASSETUP.EXE from the BIN folder. Doubleclick the ASSETUP.EXE to run the DVD.
3.
Click the Intel Network Connections Software to begin installation.
4.
Click Install Drivers and Software option to begin installation.
ASUS RS100-E6/PI2
7-19
7-20
5.
Click Next when the Intel(R) Network Connections–InstallShield Wizard
window appears.
6.
Toggle I accept the terms in the license agreement and click Next to
continue.
7.
Click the Intel(R) PROSet for Windows Device Manager box, and then click
Next to start the installation.
Chapter 7: Driver installation
8.
Follow the screen instructions to complete installation.
9.
When finished, press Finish to continue.
ASUS RS100-E6/PI2
7-21
7.4
VGA driver installation
This section provides instructions on how to install the Aspeed® Video Graphics
Adapter (VGA) driver.
You need to manually install the Aspeed® VGA driver on a Windows® Server
operating system.
To install the Aspeed® VGA driver
1.
2.
3.
7-22
Restart the computer, then log on with Administrator privileges.
Insert the motherboard/system support DVD to the optical drive. The support
DVD automatically displays the Drivers menu if Autorun is enabled in your
computer.
The Drivers menu if Autorun is enabled in your computer.
Click Next to start the installation.
Chapter 7: Driver installation
4.
Click Install to update the VGA driver.
5.
When the installation completes, click Finish to restart your computer before
using the program.
ASUS RS100-E6/PI2
7-23
7.5Management applications and utilities
installation
The support DVD that came with the motherboard package contains the drivers,
management applications, and utilities that you can install to avail all motherboard
features.
The contents of the support DVD are subject to change at any time without
notice. Visit the ASUS website (www.asus.com) for updates.
7.5.1
Running the support DVD
Place the support DVD to the optical drive. The DVD automatically displays the
Drivers menu if Autorun is enabled in your computer.
If Autorun is NOT enabled in your computer, browse the contents of the support
DVD to locate the file ASSETUP.EXE from the BIN folder. Double-click the
ASSETUP.EXE to run the DVD.
7.5.2
Drivers menu
The Drivers menu shows the available device drivers if the system detects installed
devices. Install the necessary drivers to activate the devices.
The screen display and driver options vary under different operating system
versions.
7-24
Chapter 7: Driver installation
7.5.3
Utilities menu
The Utilities menu displays the
software applications and utilities
that the motherboard supports.
Click an item to install.
7.5.4
Make disk menu
The Make disk menu contains
items to create the Intel ICH10R
and LSI MegaRAID driver disks.
7.5.5
Contact information
Click the Contact tab to display
the ASUS contact information.
You can also find this information
on the inside front cover of this
user guide.
ASUS RS100-E6/PI2
7-25
7-26
Chapter 7: Driver installation

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement