- No category
advertisement
Avery Berkel Technical Specification
T204
T204
super-precision beam cell
Description
A precision single-bridge shear beam force transducer manufactured in die steel with electroless nickel plating, designed for use in low profile platform scales and load cell in con-rod conversions of mechanical scales.
These transducers are mounted at one end and the load applied to the free end, via a through drilled hole or, with a blind hole machined to half the depth of the beam.
Capacities (E max
)
750 kg, 1500 kg, 3000 kg.
Accuracy
4000d OIML R60.
Approvals
OIML R60 Certificate No.
R60/1991-GB.97.02
Accuracy class C4.
V min
= E max
/15000
Examples of Use
● Low profile platform scales.
● Load cell in con-rod conversions of mechanical scales.
● Hoppers, tanks and silos.
● Overhead track scales.
● Engine test stands.
● Dynamometers.
Special Features
● Exceptional accuracies.
● Low profile.
● Simple to install.
● Insensitive to side loads.
● Excellent repeatability.
● Small creep and hysteresis errors.
● Special version, approved for use in hazardous areas to
CENELEC standards.
Specification
Resistance to Dirt &
Moisture
Sealed to BS EN 60529:1992
Classification IP65 & IP67.
Protection against total immersion in water for 30 minutes at a pressure corresponding to a 1 m head of water.
Enclosure
Strain gauges are encapsulated in butyl rubber and silicone sealant with an adhesed neoprene rubber cover.
Neoprene has excellent weathering/ageing resistance and is resistant to oils, refrigerants and mild acids. It may be affected by aromatic and halogenated hydrocarbons.
Avery Berkel
1
T204
Avery Berkel Technical Specification
Specification
Electrical Excitation (Recommended)
Electrical Excitation (Maximum)
Terminal Resistance (Input at 20
°
C)
Terminal Resistance (Output at 20
°
C)
Rated Output
Zero Balance
* Combined Error
Repeatability
30 min Creep and Zero Return (OIML R60)
Temperature Effect on Rated Output (-10
°
C to 40
°
C)
Temperature Effect on Zero Balance (-10
°
C to 40
°
C)
Overload Rating without affecting Performance
Ultimate Overload Rating
Maximum Permissible Side Load
Insulation Resistance (Minimum)
Deflection at Rated Output (750 kg, 1500 kg)
(3000 kg)
10V AC or DC
15V AC or DC
410
Ω
Nominal
350
Ω
Nominal
1.75mV/V
±
0.1%
±
1.0% Rated Output
±
0.012% Rated Output
0.01% Rated Output
±
0.0125% Rated Output
±
0.001%/
°
C
±
0.0025%/
°
C Rated Output
150% Rated Output
200% Rated Output
50% Rated Output
5,000 megohms
0.3 mm Nominal
0.8 mm Nominal
* The combined error is the maximum deviation from the true value (straight line drawn from zero to full load) when either applying or removing the load.
Electrical Termination
6 Core standard lengths 4.0 m and 10.0 m.
Input: black -ve, green +ve
Output: red -ve, white +ve
Reference: blue -ve, brown +ve
Note:
6 core cables may be shortened without affecting performance.
Hazardous Area Version
Special version approved for use in hazardous areas to CENELEC standards.
DEMKO certificate 97D.122103.
EEx ia II C T6.
U max in
I max in
W max in
L eq
C eq
24 V
400 mA
1.3 W
0
0
T
R1
R3
R2
T
T
R4
+ Brown
REFERENCE RETURN
Blue
+ Green
INPUT
Black
+ White
OUTPUT
Red
Screen
(not connected at load cell)
Circuit Diagram.
2
Avery Berkel Technical Specification
T204
Applications
M
L
Mounting
The transducer should be mounted using high tensile bolts, grade 8.8 (minimum), and tightened to a torque of 70 Nm.
Loading
A
L
L = Load Direction
M = Mounting Screws
This transducer is designed to operate with loads applied to the free end of the beam only.
If loads in excess of the rated capacity are envisaged, then suitable adjustable overload stops should be provided and adjusted to operate between 100% and
150% of rated capacity.
Platform Feet
For platform applications, two types of self-aligning, height adjustable feet are available as accessories:
1. For standard weighing applications, a stainless steel and nitrile rubber foot for use with the
Blind Hole version of the T204.
Nitrile rubber has good mechanical properties and is resistant to a wide range of petroleum oils and fluids.
It may be affected by aromatic and halogenated hydrocarbons.
2. For precision weighing applications and/or where aggressive chemicals may be present, an all stainless steel rolling ball foot for use with the
Through the Hole version of the
T204.
Rolling Ball
Foot Assembly
Nitrile Rubber
Foot with
Spherical
Loading Button using Blind
Hole Load Cell
View 'A'
Loading example - Low Profile Platform Scale.
Blind Hole T204
Ø80
Edge of Platform
Edge of Platform
Stainless steel/nitrile rubber foot for standard applications.
T204 Beam Cell
T204 Beam Cell
64-76 Adjustable
10
77-86 Adjustable
Through Hole T204
Ø75
All stainless steel ball foot for precision applications.
3
T204
Avery Berkel Technical Specification
Dimensions
Through Hole Version
195 195
32 30 32
32
63.5
3 Holes Ø12.2
750kg Version
96.5
93
17 63.5
96.5
93
17
32
Blind Hole Version
195
2 Holes Ø12.2
1 Hole Ø17.5
1500kg & 3000kg Version
30
32 30
63.5
96.5
93
17
32
2 Holes Ø12.2
1 Hole Ø18 x 15 deep
Chamfered at 60
°
x 5 Deep
This brochure contains a general guide only of the product and shall not form part of any contract unless specifically agreed by Avery Berkel in writing in each case on the Order Acknowledgement.
The specification of the products described herein may vary from time to time and may be altered without notice.
Your local distributor:
Avery Berkel
R
E
G
ISTER
E
D
FM 01255
E mail: [email protected]
Internet: http://www.averyberkel.com
Foundry Lane, Smethwick,
West Midlands, England B66 2LP.
Tel: +44 (0)870 90 34343 Fax: +44 (0)121-555 6062
T204/12.99/Issue 4
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement